Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
3 Aug 2018, 9:00 amClosed
electrocardiography ekg/ecg units Electrocardiography Ekg/ecg Units ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values FEATURES Mobility
portability Protective splashproof case for clean storage and safe transport - Heart rate measurement range to be at least 30 to 250 bpm
with accuracy better than ± 5 bpm yes - Heart rate trend display of at least previous 24 hours yes - In built Software and/or standard of communication yes - Heat Dissipiation: Should maitain nominal Temp and the heat should be disbursed through a exhaust cooling fan yes - User interface manual - Noise Lavel (dba) - - Electrical protection provided by fuses in both live and neutral yes - 1/4 supply lines Operating condition: Capable of operating continuously in ambient temperature of 0 to 50 deg C and relative humidity of 15 to 90% in ideal circumstances yes - Arrhythmia detection facility required; minimum gradation of 1 bpm yes - Functional requirements: electricity;AC-powered; bedside device designed to continuously detect
measure
and display a patient’s electrocardiogram through leads and sensors attached to the patient
it also typically display heart rate
the device is typically equipped with audible and/or visual alarms that are triggered when the patien's parameters drop below or exceed pre-set limits: Continuous display of patient ECG and heart rate on screen
Allows display of single
5 lead ECG or simultaneous display of at least 5 waves selected from up to 12 points Operator can set audiovisual alarm levels for low or high heart rate Operates from mains voltage or from internal rechargeable battery yes - Power consumption - - weight - - Power cable length (meter) 3 METER OR MORE - Display must allow easy viewing in all yes - 2/4 ambient light levels Audiovisual alarms required: high and low heart rate; operator variable settings
cardiac arrhythmia
sensor/wire disconnected
low battery yes - STANDARDS AND SAFETY
CERTIFICATIONS Certification(s) CE Approved product - MISCLANEOUS Warranty (years) 3 3
5 Higher is better power input and frequency 220 To 240V
50 Hz AC - Certificate of Calibration and Inspection to be provided YES - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sandeep Negi 248146
23rd bn itbp seemadwar dehradun 1 15
403848
GEM/2018/B/57153
electrocardiography ekg/ecg units
15 days
Uttarakhand; Dehradun
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| electrocardiography ekg/ecg units Electrocardiography Ekg/ecg Units ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values FEATURES Mobility | - | - | - |
| portability Protective splashproof case for clean storage and safe transport - Heart rate measurement range to be at least 30 to 250 bpm | - | - | - |
| with accuracy better than ± 5 bpm yes - Heart rate trend display of at least previous 24 hours yes - In built Software and/or standard of communication yes - Heat Dissipiation: Should maitain nominal Temp and the heat should be disbursed through a exhaust cooling fan yes - User interface manual - Noise Lavel (dba) - - Electrical protection provided by fuses in both live and neutral yes - 1/4 supply lines Operating condition: Capable of operating continuously in ambient temperature of 0 to 50 deg C and relative humidity of 15 to 90% in ideal circumstances yes - Arrhythmia detection facility required; minimum gradation of 1 bpm yes - Functional requirements: electricity;AC-powered; bedside device designed to continuously detect | - | - | - |
| measure | - | - | - |
| and display a patient’s electrocardiogram through leads and sensors attached to the patient | - | - | - |
| it also typically display heart rate | - | - | - |
| the device is typically equipped with audible and/or visual alarms that are triggered when the patien's parameters drop below or exceed pre-set limits: Continuous display of patient ECG and heart rate on screen | - | - | - |
| Allows display of single | - | - | - |
| 5 lead ECG or simultaneous display of at least 5 waves selected from up to 12 points Operator can set audiovisual alarm levels for low or high heart rate Operates from mains voltage or from internal rechargeable battery yes - Power consumption - - weight - - Power cable length (meter) 3 METER OR MORE - Display must allow easy viewing in all yes - 2/4 ambient light levels Audiovisual alarms required: high and low heart rate; operator variable settings | - | - | - |
| cardiac arrhythmia | - | - | - |
| sensor/wire disconnected | - | - | - |
| low battery yes - STANDARDS AND SAFETY | - | - | - |
| CERTIFICATIONS Certification(s) CE Approved product - MISCLANEOUS Warranty (years) 3 3 | - | - | - |
| 5 Higher is better power input and frequency 220 To 240V | - | - | - |
| 50 Hz AC - Certificate of Calibration and Inspection to be provided YES - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sandeep Negi 248146 | - | - | - |
| 23rd bn itbp seemadwar dehradun 1 15 | - | - | - |
Exempted
8 Aug 2018
30 Jul 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_403848.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .