Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.1 CrAccepted-AOC | ₹19.1 Cr Quoted ₹19.8 Cr | L1 | Accepted-AOC BEING THE LOWEST BIDDER |
| 2 | L2₹22.5 CrRejected-Finance CHINAR COMMERCIAL COMPLEX THE BUND RESIDENCY ROAD SRINAGAR 190 001 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190001 | ₹22.5 Cr | L2 | Rejected-Finance BEING OTHER THAN THE LOWEST BIDDER |
| 3 | L3₹23.3 CrRejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | ₹23.3 Cr | L3 | Rejected-Finance BEING OTHER THAN THE LOWEST BIDDER |
| 4 | L4₹23.7 CrRejected-Finance 1027 SECTOR 21B CHANDIGARH 160022 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160022 | ₹23.7 Cr | L4 | Rejected-Finance BEING OTHER THAN THE LOWEST BIDDER |
Tender Value
₹22.0 Cr
EMD Value
₹14.2 L
Closing Date
14 Oct 2024, 6:00 pmClosed
CE (AF) Nagpur
HQ CE (AF) Nagpur Vayusena Nagar Nagpur-07
PROVISION OF NEW STORAGE ACCOMODATION FOR SITE-I, SITE-II AND SITE-III AT AF STATION CHANDIGARH
2024_MES_656761_2
AF_CHD_801224
Open Tender
Civil Works
750 days
Chandigarh
For MES Enlisted Contractors- Class SS Category a (i) For other Contractor meeting enlistment Criteria of MES for Class SS Category a (i)
8 documents required · 8 mandatory
₹3,000
GE AF MC CHANDIGARH
₹14.2 L
Yes
11 Nov 2024
2 Sept 2024
21 Oct 2024
2 Sept 2024
14 Oct 2024
23 Sept 2024
3 Sept 2024 - 11 Sept 2024
Amount
Blank
Blank
Blank
Blank
Blank
Blank
Blank
Blank
Blank
Blank
Blank
Blank
Blank
Blank
SCH 'A' PART XVI (MISC B/R & E/M ITEMS) Note:- Excavation and earthwork to the extent required for execution of relevant item under this schedule unless otherwise specified shall be measured and paid under relevant items of Schedule 'A' Part-II.
INTERNAL WATER SUPPLY
Supply and fixing for angle valve of cast copper alloy chromium plated fancy type screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed 15mm bore(concealed) complete all as specified and as directed.
Supply and fixing for two way bib taps, 15mm size fancy type cast copper alloy chromium plated fancy type screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
INTERNAL ELECTRIFICATION
Supply and fixing for SPD of capacity 32 A,4 Pole type C,12.5 KA. Complete all as specified and as directed.
Supply and fixing for SPD of capacity 40 A,4 Pole type C,12.5 KA ,Complete all as specified and as directed.
Supply & fix Air Circulator fans 230 volts single phase oscillating 600 mm sweep and 1440 RPM suitable for wall mounting complete all as specified and as directed.
Supply & fix LED High bay fitting 150 W, high efficiency round highbay in PDC housing suitable for industrial application. The luminaire should have efficacy of 110 lm/w and IP 66 complete all as specified and as directed.
S&F mild steel tube axial flow fan industrial type 600 to 800mm dia,10 CUM/SEC (10000CFM) AC415 Volts 50 Hz, fire retardent body,with capacity to withstand 400 Degree Celcius for 02 hours, with flow from motor to impeller,with motor position at the centre of impeller, with provision protection net installed at both the end,terminal box, view port with totally enclosed protection of class "H" with minimum of IP65 protection, with provision of vibration isolater mounts, Impeller of aluminium alloy and allied works, including cutting hole in PEB structure and the fan and suitable capacity of motor unit and tested as per EN:14986,EN:13857,EN:13463 all as specified and as directed.
S&F bracket made out of GI pipe light grade 32 mm dia of 1.2 mtr long bend to shape for mounting LED street light fitting with MS clamps of suitable size complete with nut bolts and washers incl grouting on wall etc all as specified and directed
EXTERNAL WATER SUPPLY
Cutting the existing GI line of 100 mm dia and insert the tee of size 100x100x50 including making thread & including all fititngs etc complete all as specified and as directed.
Material and Labour construction of brick masonry valve pit of size 60 x 60 x 60 cm (internal dimensions) (depth to be reckoned from the top of PCC in foundation to the top of MS cover) with MS top cover 3.25 mm thick sheet, fixed on frame made out of angle iron 40 x 40 x 6 mm thick, with locking arrangement including two coats of black synthetic enamel paint over a coat of red oxide primer to steel and iron surfaces, brick work in cement mortar 1:4, 15 mm thick plastering in cement mortar 1:4 (internally and externally), 150 mm thick plain cement concrete 1:4:8 type D-2 using 40 mm graded mechanically crushed stone aggregate for base, 100 mm thick plain cement concrete 1:2:4 type B-1 using 20 mm graded mechanically crushed stone aggregate for coping, two coats of white wash internally after preparing the surfaces complete all as specified and as directed.
EXTERNAL ELECTRIFICATION
Supply, Installation , testing and commissioning of 11KV outdoor extensible 03 way ring main unit floor mounted with copper bus bars having raychem sleeved, consisting of 01 No incoming 630A motorised and manually operated vacuum circuit breakers & 02 Nos outgoing fixed vacuum circuit breaker & 01No. Air insulated BUS PT panel coupled with RMU. All live parts, bus bars, VCBs connections of RMU should be enclosed in one tank to avoid multiple interconnections & sealed for life robotically welded stainless steel tank 3mm thick having IP67 degree of protection filled with gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. RMU should complete with all accessories such as ring core CTs, self powered micro processor based numerical protection relay for O/C, S/C and E/F, cable supports, all front cable terminations, mechanical indications for breaker ON/OFF/Trip/Spring charged, Manometer as per IEC standards 62271-200, 60056, 60129, 60265, 60298, 60420, 60529 and 60694. Altitude of installation upto 1000m as per IEC 60120. Bushings bolted type top mounted outside the tank for connection of external busbar. Each Vacuum circuit breaker module should consist of following accessories:
Item No. 16.11 contd... 630A Vacuum circuit breaker module for making and breaking of fault current alongwith off-load isolator in series for isolation purpose & integral series earth switch of full making capacity Short time current- 21KA/ 3sec Making capacity - 52.5KA Auxiliary contacts - 1No + 1NC Maximum width - 340mm for compact design Maximum depth - 900mm for compact design Power frequency withstand voltage - 28KV Impulse withstand voltage - 95KV Nominal operating gas pressure - 1.4 Bar abs. Front cover mechanism - IP2X Cable covers - 4X Internal arc type tested 24V DC motorised spring charging mechanism for breaker operation Push buttons for breaker ON/OFF Cable box for front termination of the cable suitable upto 3 core 300 Sqmm 11KV XLPE Cable Right angle boots(push on type) Make: Schneider/ Siemens/ ABB Self powered microprocessor based relay 3O/C + 1E/F with low and high set for over current and earth fault. Relay should have facility to display the maximum loaded phase current also. Relay should be flush mounted having facility to trip the breaker from remote commands without shunt trip coil alongwith HMI screen interface Panel mounted 11KV Ring core CTs 5P10 for protection as per IEC 60185 Panel mounted 11KV ring core CTs Class 1.0 for metering as per IEC 60185 LV compartment mounted on top consisting of Digital multifunction meter (A, V, KW, KVA, F, PF) type Rishabh RISH 3430/ Conserve EM6400 Indicating lamps
Item No.16.12 contd AXIAL FLOW FAN with thermostat on the Top with MCB Protection BUS-BARS - 200 amps TP Copper bus bars SMPS POWER SUPPLY: 24 V, 9A SMPS power Supply for TSM Firing with protection on incoming & Outgoing INCOMER : 200 Amp TP,MCCB, Thermal magnetic, adjustable with O/L & S/C protection, 100% Ics =Icu, 36 KA MAKE - L&T/GE/Legrand/ABB OUTGOING ( BANK PROTECTION) HRC Fuse sets for backup of Group - I - 1 Nos of 25Kvar Group - II - 1 Nos of 25Kvar Group - III – 1 Nos of 25 Kvar MAKE - L&T / GE / SIEMENS / ABB Glass fuse links 2A, with base for Thyrister module Protection MAKE – Connect well / FTC / Phoenix THYRISTOR MODULE – Electronic Thyristor Switching Module( Not SSR- solid state relay) should be capable of Voltage peak withstand capacity of upto 2200 V PIV. They should be installed in separate enclosure with heat sink , firing card and axial fan for its cooling operation Group - I - 1 Nos of 25Kvar Group - II - 1 Nos of 25Kvar Group - III – 1 Nos of 25 Kvar Item No.16.12 contd CAPACITORS: Capacitor should be Super Heavy Duty( MDXL) with 525V, 50Hz capable of withstanding current up to 4xIn and temperature withstanding up to 70 deg C temperature on its surface without any detoriation in its lifespan Group - I - 1 Nos of 25Kvar Group - II - 1 Nos of 25Kvar Group - III – 1 Nos of 25 Kvar
Supply install, testing and commisioning of LT panel electrical Panel board floor mounted cubical type, outdoor type aesthetically designed fabricated of 3 mm thick outer CRCA sheet and 2mm thick inner CRCA sheet with front and rear opening confirming to IS-8623and incl of bus bar chamber and cable alley, danger notice board powder coated rust proof paint connecting incoming and outgoing cable connections with suitable lugs nut bolts washers and cable glands prewired complete with suitable size PVC insulated fire retardant copper conductor complete as directed and shall consists of the following items:-Main LT Panel (a) Copper bus bar of rating 1000 Amp for phases and 500 Amp for neutral mounted on Porcelain insulators - 4 strips (b) Phase indicating lamps ( RYB)- 3 Nos (c ) Multifunction meter for measuring ampere,voltage, frequency etc complete - 1 No (d) ACB 630 Amps 04 pole 50 KA - 1 No. for incoming (e) MCCB 500 Amps 36 kA 4 pole with thermal and magnatic release - 01 No. for (AMF) (e ) MCCB 100 Amps 25 kA 4 pole with thermal and magnatic release - 02 No. for (01 Nos O/G + 01 nos spare) (f) MCCB 63 Amps 16 kA 4 pole with thermal and magnatic release - 01 No. for (01 Nos O/G for Site III (g) MCCB 160 Amps 25 KA 04 Pole for connecting up APFC Panel with in LT panel.- 01No. Complete all as specified and as directed.
Supply install, testing and commisioning of LT electrical Panel board floor mounted cubical type, outdoor type aesthetically designed fabricated of 3 mm thick outer CRCA sheet and 2mm thick inner CRCA sheet with front and rear opening confirming to IS-8623and incl of bus bar chamber and cable alley, danger notice board powder coated rust proof paint connecting incoming and outgoing cable connections with suitable lugs nut bolts washers and cable glands prewired complete with suitable size PVC insulated fire retardant copper conductor complete as directed and shall consists of the following items:-LT Panel cum AMF (a) Copper bus bar of rating 600 Amp for phases and 300 Amp for neutral mounted on Porcelain insulators - 4 strips (b) Phase indicating lamps ( RYB)- 3 Nos (c ) Multifunction meter for measuring ampere,voltage, frequency etc complete - 1 No (d) MCCB 400 Amps 25 kA 4 pole with Microprocessor thermal and magnatic release - 02 No. for incoming (01 for main + 01 for DG) (e ) MCCB 350 Amps 25 kA 4 pole with thermal and magnatic release - 01 No. for O/G Site I & II (f) MCCB 125 Amps 25 KA 4 pole with thermal and magnatic release - 01 No. for O/G Site III (g) MCCB 200 Amps 25 KA 4 pole with thermal and magnatic release - 01 No. for O/G Fire fighting (g) Provision for contractor and necessary connected items in panel. complete all as specified and as directed.
Supply install, testing and commisioning of LT electrical panel board floor mounted cubical type, outdoor type aesthetically designed fabricated of 3 mm thick outer CRCA sheet and 2mm thick inner CRCA sheet with front and rear opening confirming to IS-8623and incl of bus bar chamber and cable alley, danger notice board powder coated rust proof paint connecting incoming and outgoing cable connections with suitable lugs nut bolts washers and cable glands prewired complete with suitable size PVC insulated fire retardant copper conductor complete as directed and shall consists of the following items:- LT Panel (Site I & II) (a) Copper bus bar of rating 200 Amp for phases and 200 Amps for neutral mounted on Porcelain insulators - 4 strips (b) Phase indicating lamps ( RYB)- 3 Nos (c ) Multifunction meter for measuring ampere,voltage, frequency etc complete - 1 No (d) MCCB 125 Amps 25 KA 4 pole with thermal and magnatic release - 1 No. for incoming (e ) MCCB 32 A 16 kA 4 Pole with thermal and magnetic release - 03 Nos for O/G. complete all as specified and as directed.
Supply install, testing and commisioning of LT electrical panel board floor mounted cubical type, outdoor type aesthetically designed fabricated of 3 mm thick outer CRCA sheet and 2mm thick inner CRCA sheet with front and rear opening confirming to IS-8623and incl of bus bar chamber and cable alley, danger notice board powder coated rust proof paint connecting incoming and outgoing cable connections with suitable lugs nut bolts washers and cable glands prewired complete with suitable size PVC insulated fire retardant copper conductor complete as directed and shall consists of the following items:- LT Panel (Site III) (a) Copper bus bar of rating 200 Amp for phases and 200 Amps for neutral mounted on Porcelain insulators - 4 strips (b) Phase indicating lamps ( RYB)- 3 Nos (c ) Multifunction meter for measuring ampere,voltage, frequency etc complete - 1 No (d) MCCB 125 Amps 25 KA 4 pole with thermal and magnatic release - 1 No. for incoming (e ) MCCB 40 A 16 kA 4 Pole with thermal and magnetic release - 01 Nos for O/G. (f ) MCCB 32 A 16 kA 4 Pole with thermal and magnetic release - 02 Nos for O/G. complete all as specified and as directed.
Supply install, testing and commisioning of LT electrical panel board floor mounted cubical type, indoor type aesthetically designed fabricated of 2 mm thick CRCA sheet with front and rear opening confirming to IS-8623and incl of bus bar chamber and cable alley, danger notice board powder coated rust proof paint connecting incoming and outgoing cable connections with suitable lugs nut bolts washers and cable glands prewired complete with suitable size PVC insulated fire retardant copper conductor complete as directed and shall consists of the following items:- DG LT Panel for (Site I & II ) (a) Copper bus bar of rating 400 Amp for phase and 200 Amp for neutral mounted on Porcelain insulators - 4 strips (b) Phase indicating lamps ( RYB)- 3 Nos (c ) Multifunction meter for measuring ampere,voltage, frequency etc complete - 1 No (d) MCCB 250 Amps 25 KA 4 pole with thermal and magnatic release - 01 No. for incoming (e ) MCCB 125 Amps 25 KA 4pole with thermal and magnatic release - 02 No. for Outgoing (e ) MCCB 63 Amps 25 KA 4pole with thermal and magnatic release - 01 No. for Outgoing (f) MCB 32 A 16 kA TPN- 03 Nos for O/G complete all as specified and as directed.
Supply install, testing and commisioning of LT electrical panel board floor mounted cubical type, indoor type aesthetically designed fabricated of 2 mm thick CRCA sheet with front and rear opening confirming to IS-8623and incl of bus bar chamber and cable alley, danger notice board powder coated rust proof paint connecting incoming and outgoing cable connections with suitable lugs nut bolts washers and cable glands prewired complete with suitable size PVC insulated fire retardant copper conductor complete as directed and shall consists of the following items:- DG LT Panel for (Site III ) (a) Copper bus bar of rating 200 Amp for phase and 100 Amp for neutral mounted on Porcelain insulators - 4 strips (b) Phase indicating lamps ( RYB)- 3 Nos (c ) Multifunction meter for measuring ampere,voltage, frequency etc complete - 1 No (d) MCCB 100 Amps 25 KA 4 pole with thermal and magnatic release - 1 No. for incoming (e )MCB 63 A 10 KA 4 PN- 01 Nos for O/G (f )MCB 32 A 10 KA TPN- 03 Nos for O/G copmplete all as specified and as directed.
M&L for boring of hole under road, pavement, hard standing by trench less technology using ultrasound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
LIGHTINING PROTECTION
Supply and fixing for DMC earthing strip insulators of size 25 x 3 mm durable,weather proof, heat resistant complete all as specified and as directed.
STAND BY DG SET
Supply, installing, testing and commissioning of diesel engine driven as per of CPCB –IV Plus compliance norms acoustic enclosures driven generating set 320 KVA 3 phase ( Prime Power Rating) 4 wire 415 volts (1500 RPM 50 Hz power supply with power factor 0.8 automatic start on main failure, with fuel tank maintenance free battery and standard accessories and fitting, including PCC foundations as recommended by manufacture anti Vibration pad, sand cushioning around PCC foundation to be included in deemed rates, Tools and spares to be provided by manufacturers all as specified and directed.- a) Engine. Water cooled diesel engine , Natural aspiration - suitable capacity for 320 KVA alternator under NTP condition with provision of 10% over load for one hour in every 12 hours confirming to IS0 8528. The engine shall consist of the following :- Fly wheel, direct coupling, cooling radiator, water pump engine mounted, suitable capacity alternator for charging, air cleaner, radiator fan blower type with guard, fuel injector pump, piston, mechanical governor, fuel filter(mounted) 12 volts self regulating alternator bell driven by engine exhaust silencer heavy duty industrial type anti corrosion resistance filter, starter 24 volt DC, lubricating oil cooler, exhaust pipe . (b) OEM"S manufactured Instrument panel consisting of starting switch with key lubricant oil temperature gauge, lubricating oil pressure gauge, water temperature gauge , battery charging Ammeter, battery charging indicating lamp, hour meter with RPM indicator safety control light against low lubricating oil pressure, water over speed stop with double driven adopter. Warranty: 2 years of Unconditional- (Compressive by principal manufacturer ) (c) Brush less alternator. Alternator coupled in an indigenous alternator mounted on a strong steel fabricated frame suitable for mounting as permanent foundation. Alternator shall be confirming to BS 2613 or relevant IS-4722, type self excited self regulated with automatic voltage regulator rating -400 KVA at 0.8 PF lagging 4 pole horizontal at NTP condition. Speed 1500 RPM system 415 volt s plus minus 1 % AC phase 4 wire 50 Hz, connection -4 wire star connection enclosure screen protection drip proof. Ventilation - Self ventilated insulation - Class H.
FIRE ALARM AND FIRE SYSTEM
Supply, fix, test and commission of motorized fire and smoke damper in supply air duct / main branch, return air duct as and where required of required sizes. The fire damper shall be motorized and spring return type so as to close the damper automatically in the event of power failure and open the damper when power is restored. The spring return action shall be inbuilt mechanism and not externally mounted. The Fire & smoke damper shall be complete with electronic temperature sensor and electrically operated actuator and interconnecting wiring between AHU & dampers .The damper shall also be closed in the event of fire signal. The fire damper shall be located in the supply / return air ducts.The control panel shall be located such that the reset can be done easily complete all as specified and as directed for Fire Damper
Supply, fix, test and commission of motorized fire and smoke damper in supply air duct / main branch, return air duct as and where required of required sizes. The fire damper shall be motorized and spring return type so as to close the damper automatically in the event of power failure and open the damper when power is restored. The spring return action shall be inbuilt mechanism and not externally mounted. The Fire & smoke damper shall be complete with electronic temperature sensor and electrically operated actuator and interconnecting wiring between AHU & dampers .The damper shall also be closed in the event of fire signal. The fire damper shall be located in the supply / return air ducts.The control panel shall be located such that the reset can be done easily complete all as specified and as directed for Actuator with smoke/fire sensor
Supply, installation, testing and commissioning of Pressure switch of approved make for Hydrant pump, jockey pump , Diesel Engine Driven pump and terrace pumps including necessary wiring and cut off valve up to central panel & other material as described in specifications.complete all as specified and as diirected.
Suppy and fix Air cushioning tank (Air vessel ) 250mm ida x 1000mm high with dished top, made of minimum 6mm thick MS Pipe /Plate complete with 20mm dia. Brass air valve (Ball type) , 20mm dia stop valve, pressure gauge with brass stop cock, nipple tees elbows and all accessories complete. One for Pum room and one for Terrace, complete all as specified and as directed.
Providing and fixing exhaust pipe, Diesel engine driven pump exhaust M. S. pipe class 'C' 150 mm dia including fitting like flanges, bends, reducers, etc. 50 mm thick fibre wool insulation aluminium cladding, 21 gauge, necessary excavation, fixing of silencer connections at engine exhaust, necessary supports, back filling, cutting and making good, bird proof and weather proof flap complete in all respect as directed.
Item No. 16.27 Contd Outgoing: i) 1 Nos. 160 A TPN MCCB 35 KA. 1 NOS. ii) 2 NoS. 63 A TPN MCCB 25 KA. iii) One Nos.Self Starters complete with . ON/OFF, indication lamp, contactors ammeter with suitable C.T's, sufficient nos. of potential free spare contacts, etc. suitable for 60 HP motor. iv) Wiring from pressure switch to starter - Lot v) One (1) No. DOL Starter with single phase protection feature. ON/OFF, indication lamp, contactors ammeter with suitable C.T's, sufficient nos. of potential free spare contacts, etc. suitable for 7.5 HP motor. vi) Set of control system to make the system automatic as per functional requirements. viii) Provision for starting the diesel engine fire pump with battery charger for trickle & boost charging. The diesel engine driven fire pump shall start automatically in the event of pressure drop beyond preset limit on mains failure or failure of electrical driven pumps to start. viii) Provision for starting the diesel engine fire pump with battery charger for trickle & boost charging. The diesel engine driven fire pump shall start automatically in the event of pressure drop beyond preset limit on mains failure or failure of electrical driven pumps to start. ix) Wiring from pressure switch to Diesel engine control panel. Note: i) Separate neutral link to be provided wherever TP MCCB are used. ii) Following provisions to be made in the fire panel:
Supply, installation, testing & commissioning of of 1100 V grade PVC copper armoured cables of size 3C X 50 Sqmm , PVC insulated PVC sheathed, including cable trays of min 300 mm width /supports as per site conditions
Supply, installation, testing & commissioning o of 1100 V grade PVC copper armoured cables of size 3C X 10 Sqmm , PVC insulated PVC sheathed, including cable trays of min 300 mm width /supports as per site conditions
Supply, installation, testing & commissioning of 1100 V grade PVC copper armoured control cables of size 4C X 1.5 Sqmm , PVC insulated PVC sheathed, including cable trays of min 300 mm width /supports as per site conditions
Supply & making end termination with brass double compression glands for the following PVC insulated, PVC sheathed & armoured 1100 V grade Aluminium cable of size 3C X 50 Sqmm including cost of crimping lugs/ferrules, compression glands, solder, cable sockets, insulation tape etc complete as required.
Supply & making end termination with brass double compression glands for the following PVC insulated, PVC sheathed & armoured 1100 V grade Aluminium cable of size 3C X 10 Sqmm including cost of crimping lugs/ferrules, compression glands, solder, cable sockets, insulation tape etc complete as required.
Supply and fixing of Body earthing of the various equipments/ motors/ switchgears supplied by the bidder of GI earth striip of size 25 mm X 4 mm , as per IS:3043 and as required including provision for connection of earthing to main earthing pits.complete all as specified and as diirected.
Supply and fixing of Body earthing of the various equipments/ motors/ switchgears supplied by the bidder wiith suitable size of earthing strip/wire for trench less excavatiion for road crossing of MS pipe 150 mm, as per IS:3043 and as required including provision for connection of earthing to main earthing pits.complete all as specified and as diirected.
Supply, Installation testing & commissioning of M.S PIPE 25mm dia (Nominal bore) Class 'C' (Heavy Duty) pipes conforming to IS : 1239 Part-I including cutting, threading, welding & all fittings like flanges, tees, elbows, bends junctions, reducers, ball valves etc. welded or screwed joints, clamps structural steel supports (as per TAC norms) or as required/ directed at site
Supply, Installation testing & commissioning of M.S PIPE 50mm dia (Nominal bore) Class 'C' (Heavy Duty) pipes conforming to IS : 1239 Part-I including cutting, threading, welding & all fittings like flanges, tees, elbows, bends junctions, reducers, ball valves etc. welded or screwed joints, clamps structural steel supports (as per TAC norms) or as required/ directed at site
Supply, Installation testing & commissioning of M.S PIPE 80mm dia (Nominal bore) Class 'C' (Heavy Duty) pipes conforming to IS : 1239 Part-I including cutting, threading, welding & all fittings like flanges, tees, elbows, bends junctions, reducers, ball valves etc. welded or screwed joints, clamps structural steel supports (as per TAC norms) or as required/ directed at site
Supply, Installation testing & commissioning of M.S PIPE 100mm dia (Nominal bore) Class 'C' (Heavy Duty) pipes conforming to IS : 1239 Part-I including cutting, threading, welding & all fittings like flanges, tees, elbows, bends junctions, reducers, ball valves etc. welded or screwed joints, clamps structural steel supports (as per TAC norms) or as required/ directed at site
Supply, Installation testing & commissioning of M.S PIPE 150mm dia (Nominal bore) Class 'C' (Heavy Duty) pipes conforming to IS : 1239 Part-I including cutting, threading, welding & all fittings like flanges, tees, elbows, bends junctions, reducers, ball valves etc. welded or screwed joints, clamps structural steel supports (as per TAC norms) or as required/ directed at site
Providing and applying two coat of 4 mm thick 'PYPKOTE' antirust protection including primer and lap of 25 mm on M.S. pipe of 150mm dia in trenches or complete including surface preparation coating and wrapping shall be confirm to ISI 10221 including conducting Holiday Test.complete all as speciified and as directed.
Providing & Fixing S.S. single headed ISI marked oblique pattern hydrant landing valves with 80mm dia flanged inlet & 63 mm dia female outlet complete with gun metal cap and GI chain twist release type plugh and all accessories as per IS : 5290-1983 Type A. For 16 Yard Hydrant and 10 Internal Hydrant ) complete all as speciified and as directed.
Providing & Fixing of 63 mm dia 15 m long non-percolating flexible hose (RRL- type A) as per IS : 636. Type A with S.S. male & female instantaneous type coupling (IS 903). ( For 32 Yard Hydrant and 20 Internal Hydrant ) complete all as speciified and as directed.
Supply and fix 63 mm dia Gun Metal branch pipe with 12.5mm nozzle confirming to IS 903.( For 16 Yard Hydrant and 10 Internal Hydrant ) complete all as speciified and as directed.
Providing & Fixing of wall mounting swinging type first aid fire hose reel with drum, hanging bracket, 36.5 Mtr. length x 20 mm dia high pressure hose reel tubing as per IS: 444 with gun metal (GM) shut off nozzle having 5 mm dia orifice. The hose reel shall be conforming to IS : 884-1985. Rate shall include 25 mm dia M.S. pipe connection from Riser to hose reel, sockets, nipples, elbows and ball valve (25 mm dia). Drum shall be fixed on adjoining wall through anchor fasteners / cement concrete block as and when required.hose reel of 20 mm dia and 30 meter length confirming to IS 8090 complete all as speciified and as directed.
Providing & Fixing of weather proof standard fire hose cabinet (750 mm x 600 mm x 250 mm deep) for yard hydrants made of 16 SWG powder coated M.S. sheet having single or double opening glazed (4.0 mm thick glass) shutter including necessary locking arrangement by allan key, stove enamelled Fire red finish with " Fire Hose" marked on front, suitable for housing 2 nos. Hose pipe, 1 No. branch pipe & nozzle spanner ( For 16 Yard Hydrant and 10 Internal Hydrant ) complete all as speciified and as directed.
Providing & fixing air release valve of 25 mm dia and 25 mm dia gun metal gate valve with fittings etc. to be installed at risers. complete all as speciified and as directed.
Providing and laying light duty non pressure NP-3 Class RCC pipe S/S jointed with stiff mixture in the proportion 1:2, 300 mm dia R.C.C. Hume pipe for underground hydrant pipe at road crossings including collar pieces and filling inside of pipe with sand complete as required including necessary excavations and back filling. (For road crossing)complete all as speciified and as directed.
Providing & Fixing of bourden type Stainless Steel dial type pressure gauge with brass isolation valve and pipe. (For each internal Fire hose cabinet) complete all as speciified and as directed. Dial Diameter : 100mm Caliberation : 0-10 Kg/cm2
Supply, erection, testing and commissioning of fire brigade draw off connection confirming to IS : 4038-1986 with 150 mm Non return valve/ strainer incluiding necessary fittings the word FIRE BRIGADE DRAW OFF to be painted on the box complete all as specified and as directed.
Supply and fix MS Cabinet ( apporx 750mm x 600mm x 450 mm ) to encl fire brigade inlet connection fabricated from 16 gauge sheet with full front glass door and locking arrangement painted and mounted on masonry platform complete all as specified and as directed.
Supply, erection, testing and commissioning of THREE WAY fire brigade inlet connection to wet riser system which comprises of 3 No. 63 mm dia Gun metal NRV, 1 No. powder coated box suitable for accommodating the above components fabricated out of 16 SWG MS sheet with central opening, glazed front incluiding necessary fittings the word FIRE BRIGADE DRAW OFF to be painted on the box complete all as specified and as directed.
FIRE DETECTION AND ALARM SYSTEM
Supply,Installation,Testing and Commissioning of Flame Proof UV/IR Flame detector with Rugged Explosion-Proof and FM / ATEX / PESO Approved Enclosure. UV Range: 185-260nm, IR : 3000-5000nm, quiescent current < 80mA, separate LED indication for normal and alarm, Air Purging Provision, protection class IP 66, operating temp -10Deg.C to +55Deg.C, Confirming to NFPA 72E, FM standards class no. 3260 and IS code 2189, IP & Performance Certification by ETDC, Govt. of India. LPCB :1259 a/02 Approved. complete all as specified and as directed.
Supply, installation, testing & commissioning of certified to EN-54 Addressable Manual Pull Station Addressable integrated design complete all as specified and as directed. • All metal construction • Single action • Bi-colored status LED indicates Standby and Alarm conditions • Address should be programmable in EEPROM • Address can be programmed when installed.
Supply, installation, testing & commissioning of certified to EN-54 Isolator Base/ Module fully monitored for short circuit Ability to detect short circuit conditions complete all as specified and as directed. • Design should be for use with analog sensor. • Should have Built-in LED indication upon short circuit condition • Must contain a security locking tab for tamper protection certified
Supply, installation, testing & commissioning of of Addressable Monitor Module certified to EN-54, complete all as specified and as directed. • Single input contact monitor • Should be programmed to monitor Normally Open (NO) or Normally Closed (NC) contacts • Should operate on Class A or Class B SLC loop complete as required.and as per specifications.
Supply, installation, testing & commissioning of The Supervised addressable Dual relay output / control module shall be certified to EN-54 2A @ 24 VDC Power Limited and must be must be addressed from 1 – 127 prior to installation on the SLC loop. Modules using binary jumper or dip switch setting are not acceptable. The device address shall be electrically programmable and stored in EEPROM. A bi-colored LED shall indicate device status. Operation parameters are maintained by the module, and individual communication with the control system during emergency conditions is not requiredcomplete as requiredas per specifications. complete all as specified and as directed.
Supply, Installation Testing & Commissioning of Active Repeater Panel to be integrated with Fire Alarm Control Panel,larger display Full colour 800 x 480 LCD with resistive touch screen and automatic back-light dimming and the status of any Fire/Fault of Integrated Fire Alarm Panels.Panel Should Include Battery charger with 2 Nos. 12 Volt Battery Backup upto 6.0 hours.Panel should compliant with EN54-2. complete all as specified and as directed
Supply, Installation Testing & Commissioning of microprocessor based Networkable Analogue Addressable Fire Alarm Control Panel. The Panel shall be compliant with EN54-2, EN54-4 and approved by LPCB. The Fire Alarm Control Panel shall have expandable capacity up to 04 loops. The Panel must have Full colour 800 x 480 LCD with resistive touch screen and automatic backlight dimming. The Panel must also have the capability to take Addressable Intelligent Wired and Wireless Devices on same loop. Each loop shall have a capacity of 127 analogue Addressable devices and 127 Base sounders/Base Sounder Beacons. The panel shall have an event log of minimum 10,000 events @ 1 second resolution, Filterable and Printable. The Panel shall have Three access levels. Panel shall support upto 5000 Cause & Effects entries, with upto 20,000 inputs controlling & 20,000 Controlling outputs across the network. The Panel shall have capability for Peer to Peer networking through RS485 network card. The Panel must have 4 inbuilt programmable sounder circuits, each circuit rated at 2.5A.The Panel must have inbuilt 3 programmable inputs and 5 inbuilt programmable relay outputs. The Panel shall have up to sub-addressable 512 programmable Inputs/Outputs via optional RS485 COMMS serially connected expansion cards. The Panel shall have 240 V AC power supply along with automatic Battery Charger. The Panel shall be fully expandable via common plug in loop driver boards. The user shall have a choice of using the panel with 5.25 Amp or 10.25 Amp power supply unit which is inbuilt in the FACP and should be approved to EN54-4. The Panel shall have configurable via USB port to PC or memory stick. The Panel shall have dedicated RS232 serial port for optional printer.Panel Should Include Battery charger with 2 Nos. 12 Volt Battery Backup upto 6.0 hours. complete all as specified and as directed
Supply, laying, testing and commissioning of cabling for fire detection and alarm sysrem with 1.5 SQMM 2 core armoured, BS 7846 and BS 6387 certified , vol rating 600/ 1000 V. annealed tinned multi strand copper conductor PVC Insulated flexible FRLS wire in MS conduit as required.complete all as specified and as directed Note:- Rate for exclusive of MS conduit used for Fire Alarm wiring work.
Providing and fixing of 16 Gauge MS Conduit in size 20mm including the cost of junction box bends, elbow, sockets, Tee and GI flexible conduit to connect from ceiling to false ceiling etc laying in slab, cutting chasses and making good or surfaces mounting including all fixing hardware.complete all as specified and as directed.
FIRE EXTINGUISHER
Providing & fixing of ISI marked (IS: 2878) portable Co2 fire extinguisher of capacity 4.5 kg flat base including valve discharge hose of not less than 10mm dia. meter complete in all respect including initial fill with Co2 gas confirming to IS 307-1966 and filled to filling ratio of not more than 0.367.complete all as specified and as directed.
Providing & fixing of ISI marked trolley mounted fire extinguisher, 25kg wheeled Dry Powder Extinguishers complete in all respect.complete in all resp.complete all as specified and as directed.
Providing & fixing of ISI marked (IS: 2878) portable Co2 fire extinguisher of capacity 22.5 kg flat base including valve discharge hose of not less than 10mm dia. meter complete in all respect including initial fill with Co2 gas confirming to IS 307-1966 and filled to filling ratio of not more than 0.367.complete all as specified and as directed.
EOT CRANE
Supply, erect, test and commissioning of electrically operated over head travelling crane 3Ton capacity asper IS 3177/ IS 807, rail mounted double girder type class-II with hoisting mechanism, control panel electric motor and gear driven, long cross travel VVVF control dries for normal and micro speed control operated from floor and safety devices for smooth functioning of EOT crane. All motor shall be Sq cage foot/ flange mounted, gear box shall be helical type gearing duly hardened and totally enclosed complete with rope drum, wire rope with four falls complete with lockable type bottom block pulley, limit switches etc complete with EMDC brake in hoist motion. Control panel shall be made out of 16 SWG MS sheet duly powder coated with suitable rating of power/ control contactors and VVF drive for all the three motion i.e hoist, LT and CT duly wired for dual operation i.e push button with frequency control remote operation of EOT crane. New shrouded type TPN PVC insulated DSL system of suitable rating of 415 Volts, 4wire of suitable capacity, including current collector supporting brackets, insulators and other standard fixtures and fittings, buffers including all safety devices. Designing manufacturing with radio remote controller with receiver unit. The remote should have atleast two speed variations of hoist, LT and CT motion with atleast four spare push buttons including new armoured copper cable of suitable capacity for crane. Details for Crane : SPAN : 28 Mtr Hook Height : 7 mtr
AIR CONDITIONING
Supply , installation , testing & commissioning of Air Cooled Packaged Air Conditioners, comprising of Hermetically sealed Scroll Compressors with microprocessor based control, including copper refrigerant piping, electrtical interconnection between indoor and outdoor units , suitable for operation on R- 407c/R - 410a refrigerants and of nominal capacity not Less than 3X11 TR ( 02 x 11 TR Working + 01 x 11 TR Standby) with strip heater complete all as specified and directed.
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 05 KVA complete all as specified and as directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 150 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 01 KVA complete all as specified and as directed.
Supplying, installing, balancing and commissioning of site fabricated Galvanised Sheet Steel (GSS) ducts conforming to IS: 277. The shall be fabricated either from , rectangular ducting complete with neoprene rubber gaskets, elbows, splitter damper vanes, hangars, supports. Duct work shall be rigid and straight without kinks.All exposed ducts within the conditioned space shall have slip joints. Flanged joints shall not be used.Ducts shall be supported independently from the building structure and adequately, to keep the ducts true to shape. The support spacing shall be not more than 2 m.Duct connections to the air-handling unit shall be made by inserting a double canvas sleeve 100 mm longThe steel sheets shall be hot dip galvanized with MAT finish with coating of minimum 120 grams per square meter (GSM) of Zinc, GI sheets shall be lead free, eco friendly and RoHS compliant. All sheet metal connections, partitions and plenums required for flow of air through the filters, fans etc. shall be at least 1.25 mm thick galvanised steel sheets.Hanger rods shall be of mild steel and of at least 10 mm dia for ducts upto 2250 mm size, and 12 mm dia for larger sizes.All nuts, bolts and washers shall be zinc plated steel. All rivets shall be galvanised or shall be made of magnesium - aluminium alloy. Self tapping screws shall not be used.The fabrication of ducts shall be carried out as per approved drawings and specifications of following sheet thickness complete all as specifed and as directed. for 0.63 mm thickness sheet (24 gauge) for Longest side 750mm and below
Supplying, installing, balancing and commissioning of site fabricated Galvanised Sheet Steel (GSS) ducts conforming to IS: 277. The shall be fabricated either from , rectangular ducting complete with neoprene rubber gaskets, elbows, splitter damper vanes, hangars, supports. Duct work shall be rigid and straight without kinks.All exposed ducts within the conditioned space shall have slip joints. Flanged joints shall not be used.Ducts shall be supported independently from the building structure and adequately, to keep the ducts true to shape. The support spacing shall be not more than 2 m.Duct connections to the air-handling unit shall be made by inserting a double canvas sleeve 100 mm longThe steel sheets shall be hot dip galvanized with MAT finish with coating of minimum 120 grams per square meter (GSM) of Zinc, GI sheets shall be lead free, eco friendly and RoHS compliant. All sheet metal connections, partitions and plenums required for flow of air through the filters, fans etc. shall be at least 1.25 mm thick galvanised steel sheets.Hanger rods shall be of mild steel and of at least 10 mm dia for ducts upto 2250 mm size, and 12 mm dia for larger sizes.All nuts, bolts and washers shall be zinc plated steel. All rivets shall be galvanised or shall be made of magnesium - aluminium alloy. Self tapping screws shall not be used.The fabrication of ducts shall be carried out as per approved drawings and specifications of following sheet thickness complete all as specifed and as directed. for 0.80 mm thickness sheet (22 gauge) for Longest side 751 mm to 1500 mm Note for item 16.69 and 16.70 above (i) The duct work shall be as per IS 655. (ii) The GSS sheets for duct work shall conform to class viii with zinc coating of 120 gm/sq mtr as per ISS-277.
Supplying and fixing of duct thermal insulation using resin bonded fiber glass of density 24 kg/m3 with one side factory laminated aluminium foil 50mm thick to be wrapped around the duct. The insulation applied after 2 coats of cold setting adhesive (CPRX Compound). All joints shall be sealed with 50 mm wide self adhesive aluminium tape and covering with 0.63 mm x 19 mm GI wire mesh netting, butting all joints and laced with GI wire complete all as required and as specified .
Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³ shall conform to IS 8183 as amended upto date.Accoustic insulation shall be stuck to inside the ducting after applying 2 coats of cold setting adhesive (CPRX Compound). The insulation is held in position with rivets or galvanised steel bolt with counter sunk heads ,25 x 25 GI section 1.5 mm thick and GI plate washers at the centre to centre distance of 600mm.The insulation shall be covered with reinforced plastic tissue paper and 0.5 mm thick perforated aluminium sheet having perforations between 20-40% fixed to inside surface of the duct with cadmium plated nuts, bolts, stick pins,CPRX compound etc complete as required and as per specifications
Supplying and fixing Accoustic insulation lining on wall of AHU Room with 50 mm thick, 32 kg/m3, rigid bonded fibreglass. Accoustic insulation shall be fixed in 610 mm x 610 mm frame work made of 25 x 50 x 50 x 50 x 25 mm made out of 0.6 mm thick GI sheet U shaped channel shall be fixed to walls leaving 610mm from floor by means of raw plugs in walls and dash fasteners in ceiling.and covered with reinforced fibre glass tissue and finished with aluminium perforated sheet having perforation between 20-40%of thickness not less than 0.8mm shall be fixed over the entire surface neatly without causing sag/ depression in between and held with screws. Sheet joints should overlap minimum 10mm.Aluminimum beading of 25mm wide and thickness not less than 1.00 mm shall be fixed on all horizontal/ vertical joints by means of screw
Supply, installation, testing and commissioning of G.I volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws, linkages, flanges etc, as per specifications and as directed.
Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire (minimum 1.5 sqmm) for integration within AHU room complete all as specified and as directed for Damper.
Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire (minimum 1.5 sqmm) for integration within AHU room complete all as specified and as directed for Actuator.
Supplying, fixing, testing and commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring and removable core complete as per specificationss and approved drawings and schedules.
Supplying, fixing, testing and commissioning of return air diffusers of powder coated aluminium but without volume control dampers complete as per specificationss and approved drawings and schedules.
Supplying, fixing, testing and commissioning of powder coated extruded aluminium return air grills with louvres but without volume control dampers complete as per specificationss and approved drawings and schedules.
Supplying, installation, testing and commissioning of GI construction fresh air louvers with min. 60 % free area , bird screen and fresh air filters and painted in baked enamel shade with metallic frame work complete as per specification approved drawings and schedules.
S&F wind driven turbo ventilator outer dia 30’’ effective throat 24’’, Min 2000 CFM at 30 ft height w.r.t wind velocity 8 km/hr , thickness of vanes 0.5mm, minimum 2 Nos bearings, MOC : S.S for bottom & plates, industrial high grade aluminium for vanes etc and complete all as directed.
Total amount of Schedule 'A' Part XVI carried over to General Summary
Blank
Blank
Blank
GENERAL SUMMARY
Lumpsum price worked out by the contractor for "BUILDING AND STRUCTURES" as listed in Sch ‘A' Part I representing above / below the lumpsum price of Rs.13,45,70,380.00 as inserted by MES for Sch ‘A’ Part I on Srl Page No.31(R)
Lumpsum price worked out by the contractor for “SITE CLEARRANCE, EXCAVATION AND EARTHWORK" as listed in Sch ‘A” Part II representing above / below the lumpsum price of Rs. 29,19,020.95 as inserted by MES for Sch ‘A’ Part II on Srl Page No.32(R)
Lumpsum price worked out by the contractor for "INTERNAL WATER SUPPLY” as listed in Sch ‘A” Part III representing above/below the lumpsum price of Rs. 18,274.62 as inserted by MES for Sch ‘A’ part III on Srl Page No. 33(R)
Lumpsum price worked out by the contractor for "INTERNAL ELECTRIFICATION” as listed in Sch ‘A” Part IV representing above/below the lumpsum price of Rs. 14,51,605.63 as inserted by MES for Sch ‘A’ part IV on Srl Page No.38(R)
Lumpsum price worked out by the contractor for “EXTERNAL WATER SUPPLY” as listed in Sch ‘A” Part V representing above/below the lumpsum price of Rs. 82,508.21 as inserted by MES for Sch ‘A’ Part V on Srl Page No.39(R)
Lumpsum price worked out by the contractor for “EXTERNAL ELECTRIFICATION" as listed in Sch ‘A” Part VI representing above/below the lumpsum price of Rs. 48,92,630.11 inserted by MES for Sch ‘A’ Part VI on Srl Page No.43(R)
Lumpsum price worked out by the contractor for “ROAD/PATH/CULVERT"' as listed in Sch ‘A” Part VII representing above/below the lumpsum price of Rs. 1,37,08,386.70 inserted by MES for Sch ‘A’ Part VII on Srl Page No. 44(R)
Lumpsum price worked out by the contractor for “ SEWAGE DISPOSAL” as listed in Sch ‘A” Part VIII representing above/below the lumpsum price of Rs. 8,31,604.36 as inserted by MES for Sch ‘A’ Part VIII on Srl Page No. 47
Lumpsum price worked out by the contractor for “AREA DRAINAGE” as listed in Sch ‘A” Part IX representing above/below the lumpsum price of Rs. 39,55,947.73 as inserted by MES for Sch ‘A’ Part IX on Srl Page No. 49
Lumpsum price worked out by the contractor for “LIGHTNING PROTECTION” as listed in Sch ‘A” Part X representing above/below the lumpsum price of Rs. 3,97,281.88 as inserted by MES for Sch ‘A’ Part X on Srl Page No. 51
Lumpsum price worked out by the contractor for "STAND BY DG SET ” as listed in Sch ‘A” Part XI representing above/below the lumpsum price of Rs. 70,248.80 as inserted by MES for Sch ‘A’ Part XI on Srl Page No. 52
Lumpsum price worked out by the contractor for “FIRE ALARM AND FIRE FIGHTINING SYSTEM ”as listed in Sch ‘A” Part XII representing above/below the lumpsum price of Rs. 22,08,265.00 as inserted by MES for Sch ‘A’ Part XII on Srl Page No. 56(R)
Lumpsum price worked out by the contractor for “EOT CRANE”as listed in Sch ‘A” Part XIII representing above/below the lumpsum price of Rs. 15,145.80 as inserted by MES for Sch ‘A’ Part XIII on Srl Page No. 57(R)
Lumpsum price worked out by the contractor for “AIR CONDITIONING ”as listed in Sch ‘A” Part XIV representing above/below the lumpsum price of Rs. 3,80,287.94 as inserted by MES for Sch ‘A’ Part XIV on Srl Page No. 58
Lumpsum price worked out by the contractor for “DEMOITION/DISMANTLING/TAKING DOWN”as listed in Sch ‘A” Part XV representing above/below the lumpsum price of Rs. 14,53,013.84 as inserted by MES for Sch ‘A’ Part XV on Srl Page No. 59
Total amount of SCHEDULE 'A' PART XVI (MISC B/R & E/M ITEMS) brought forwarded from Serial Page No. 85
M M SHAWL Engineers and contractors pvt ltd (BID ID -3131069)
M P TYAGI ENGINEERS AND CONTRACTORS (BID ID -3124562)
H.P. CONSTRUCTION CO. (BID ID -3130766)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid