Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC | ₹1.2 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.8 Cr+₹57.7 L (48.5%)Rejected-Finance VILLAGE KAIRWAN KARANPUR PO RAJPUR DEHRADUN | DEHRADUN | DEHRADUN | UTTARAKHAND | ₹1.8 Cr+₹57.7 L (48.5%) | L2 | Rejected-Finance L2 |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Rejected-Technical | - | - | Rejected-Technical Disqualified |
Tender Value
₹1.7 Cr
Closing Date
14 Sept 2021, 5:00 pmClosed
Superintending Engineer
Office of Superintending Engineer Construction Circle UKPJN Dehradun
CONSTRUCTION OF PUMP HOUSE LAYING OF RISING MAIN AND OTHER APPURTENANT WORKS FOR SOURCE AURGUMENTATION WATER SUPPLY SCHEME IN MAHARANIBAGH UNDER AMRUT PROGRAMME
2021_MDPEY_35940_1
Letter No. 4249/NIVIDA/253, dt. 25.08.2021
Open Tender
Civil Works
Item Rate
180 days
Dehradun
Please refer Tender documents.
4 documents required · 4 mandatory
₹11,800
Executive Engineer Central store Division UKPJN
Exempted
Dehradun
15 Jul 2022
27 Aug 2021
16 Sept 2021
28 Aug 2021
14 Sept 2021
3 Sept 2021
1 Sept 2021
Amount
Supply & Laying of Pipe Line and apputenant works Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge
Bituminous road
Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
Excavation in soil mixed with single boulder etc. requiring the use of special T&P, if any, for pipe line trenches including lift unto 1.5 m and lead unto 50 m and refilling, watering, ramming of excavated earth in to the trenches and disposal of surplus earth unto 50 m from the center of the trenches.
Providing of all materials, carting from site store to site of work, lowering into trenches with true to alignment, Laying & Jointing of full lenght S&S Centrifugally cast (spun) Ductile iron pipes including supply of "EPDM" rubber gaskets conforming to IS : 5382/1985 with testing of pipe line complete.
D.I. Pipe S&S K-9 conforming to IS: 8329/2000
200 mm dia
Providing and laying DI specials of class K-12 suitable for push - on - jointing as per IS: 9523-2000
Upto 600 mm dia
Providing push on joints to Centrifugally (spun) cast iron pipes or Ductile iron pipes including testing of joints and the cost of rubber gasket
200 mm dia
Making connection between Tube Well & exixting distribution system of following size including all material, labour, T&P etc. complete.
80 mm dia to 150 mm dai.
200 mm dia to 300 mm dai.
Disinfecting C.I./D.I. water mains by flushing with water containing bleaching powder @ 0.5 gms per litre of water and cleaning the same with fresh water, operation to be repeated three times including getting the sample of water from the disinfected main tested in the municipal laboratory.
200 mm dia
C.I. D/F Sluice Valves confirming to IS: 14846-2000 Pressure PN 1.6
200 mm dia
C.I. Air Valve Double Acting
80 mm dia
Providing and fixing Fire Hydrant (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately)
80 mm dia (Class II)
Supply of all materials, labour T&P etc. and construct following valve chambers with a floating coat of neat cement complete as per standard design : With F.P.S. bricks
Sluice Valve chambers
Air Valve chambers
Fire hydrant Chamber
Supply of all material, labour T&P etc. and provide Nala and Culvert crossing by Pipe line.
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - -All work upto plinth level 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size. For Cement Concrete Pavment:
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - -All work upto plinth level 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) For Cement Concrete Pavment:
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
Supplying and stacking at site 90 mm to 45 mm size stone aggregate
63 mm to 45 mm size stone aggregate
53 mm to 22.4 mm size stone aggregate
Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density
Surface dressing one coat on old surface with bitumen of specified grade at the rate of 1.22 kg/ sqm of surface area with 1.10 cum of stone chippings 11.2 mm nominal size per 100 sqm of road surface, including consolidation with road roller of 6 to 8 tonne capacity etc. complete :
Using bitumen emulsion (minimum 50% bitumen content- RS grade conforming to IS : 8887)
Providing and laying Dense Graded Bituminous Macadam using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specificatons and directions of Engineer-in-Charge.
50 to 100 mm average compacted thickness with bitumen of grade VG-30 @ 5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity.
Providing and laying Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in-Charge.
40/50 mm compacted thickness with bitumen of grade VG-30 @ 5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity
Providing and applying tack coat using hot straight run bitumen of grade VG - 10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications :
On bituminous surface @ 0.50 Kg I sqm
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved
Pump House & Boundry Wall & Iron Gate Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with Jamuna sand under floors including, watering, ramming consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size).
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm bed by dry brick ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Columns up to roof slab
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Reinforcement for R.c.c work Using Thermo-mechanically treated bars (density of steel 78.5q percum)
Centring and shuttering including strutting,ropping etc. and removal of form for
Foundations, footings, bases of columns, etc. for mass concrete.
Columns up to plinth level , Pillars, Piers, Abutments, Posts and Struts.
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Suspended floors, roofs, landings, balconies and access platform.
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with F.P.S. bricks of class designation 75 in superstructure Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in Cement mortar 1:4 (1 cement :4 coarse sand)
Providing and fixing pressed steel door frames confirming to IS: 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge
Profile 'B' (Single Pattam)
Providing and fixing factory made ISI marked steel glazed doors,windows and kilogram ventilators side /top /centre hung with beading and all members such as K11 B and K12 B etc.complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted with 15x3mm lugs, 10cm long, embeddedin cement concrete blocks 15x10x10cm of 1:3:6 (1 cement:3 coarse sand:6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of hinges, pivots, float glass panes with glazing clips and special metal sash putty of approved make and a priming coat of approved steel primer excluding the cost of metal beading and other fittings except necessary hinges or pivots complete as per approved design.
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 5.5 mm thick glass panes.
Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming( Girder ISMB 250X125) coat of approved steel primer all complete.
Providing and fixing fly proof galvanised M.S wire gauze to windows and clerestory windows using galvanised M.S. wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.63 mm. With 12 mm mild steel U beading.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75mm deep chase
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edge sand making and finishing the outlet complete.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :
110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.
Coupler(110 mm)
Bend 87.5 degree 110 mm bend
Shoe (Plain) 110 mm Shoe
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs,screwed with M.S. screws of required length including
12 mm thick cement plaster in 1:6 ( 1 cement and 6 fine sand) mortar including supply of all material , labour and T&P etc. required for proper completion of the work.
12 mm thick cement plaster in 1:4 ( 1 cement and 4 fine sand) mortar including supply of all material , labour and T&P etc. required for proper completion of the work.
15 mm thick cement plaster in cement mortar 1:6 on Rough face of brick wall including supply of all material , labour and T&P etc.
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 20 mm cement plaster (top of chajja)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade (New work (two or more coats) over and including priming coat with cement primer)
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture
Pointing on tile brick work with cement mortar 1:3 (1 cement :3 fine sand) Flush/ Ruled/ Struck or weathered pointing
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved byEngineer-in-charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment.b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs .
(c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep.
(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120mm and minimum thickness at khurra as 65 mm
Fencing with angle iron post placed at required distance embedded incement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with 01/05/2012 - 1horizontal wires, of barbed wire 9.38 kg per 100 m (minimum) between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately) :- Payment to be made per metre cost of total length of barbed wire used.With G.I. barbed wire corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire 9.38 kg per 100 m (minimum) between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately):- Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wire.
Supplying at site Angle iron post & strut of required size including bottom kilogram 73.30 41121 to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete. Size 50×50×6mm
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
E&M Works
Transportation of Rig Machine, Air compressor O.P unit camp equipages, connected T&P & necessary material required for drilling up to site of work, including loading, unloading etc. complete.
Errection and Leveling of Rig Machine and barricading at site of work
Dismantling of Rig Machine & Clearance of site after satisfactory completion of work.
Drilling of borehole from GL to 200 mtr BGL
Supply & Lowering of 300 mm dia MS ERW fincut 7.9 mm thick Plain pipe
Supply & Lowering of 300 mm dia MS ERW fincut 7.9 mm thick Slotted pipe
Supply & fixing of 300 mm dia, 8 mm thick tubewell cap.
Supply & fixing of 300 mm dia M.S.D.I housing clamp and Girder Set.
Supply & fixing of 300 mm dia Bail plug.
Supply & Shrouding of Pea gravel in between bore & tubewell assembly to the entire depth of tubewell.
Development of tubewell by 350 PSI/1100 CFM Air compressor.
Development of tubewell by the suitable capacity O.P unit including supply & installation of pumping plant.
Geohydrological survey of site.
Chemical & bacteriological testing of water sample
Supply of submersible pumping plant capable of delivering 1200 LPM discharge at 140 mt. head with electric motor to be operated on 415 (+\-)10% volts,3 phase,50 C\s AC supply with 5 mtrs. submersible cable
Supply and Installation of electrical panel cum starter suitable for automation with panel for submersible pumping plant of 1200 LPM discharge at 140 mt. head .
Supply of 25 sq mm PVC insulated Cu Conductor 3 core, XLPE submersible cable.
Supply of aluminium armoured cable 70 sq. mm 3.5 core
Supply of 150 mm dia x 7.1 mm thick column pipe in 3 mt. length with interlocking arrangement
Supply of150mm dia CI D\f PN-1.6 sluice valve with hand wheel
Supply of150mm dia CI D\F PN-1.6 reflux valve with hand wheel
Supply of150mm dia MS D\f pipe of 1.5 Mt. length- 2 Nos, Ventury - 1 No, 150x150x150mm dia Tee-1 No, 150mm dia CI D\F bend-2 Nos, TW Cap-1 No,
Supply of 150 mm dia MS DI clamp heavy duty - 1 Set.
Jointing material for wiring connection including lugs, thimble, insulation tapes, nutt bolts etc.
Presure Gauges with control cock & fiting, nipple, pipe, elbow etc complete- 10 Kg/Sq Cm.
Installation of pumping plants and accessories at Maharanibag tube well
Supply and installation of dosing pump of 6kg/cmsqr. Up to 4lph dosing of chlorination suitable to operate at single phase supply215+/-10%along with all necessary connecting devices complete with 200 ltr. Tanks ,along with stabilizer stands including first fill sodium hypo chloride complete in each and every respect
Testing and commissioning of pumping plants and accessories.
Complete earthing double loop with G.I Earth plate of 600mmx600mmx6mm size with earthing G.I. strips 25mmx5mm thick with charcoal salt and Earthing material as per latest IS code (Using two earthing plate and other related material)
Supply of 250 amp. 3 phase with neutral FN type main switch with HRC fuses.
Supply of tools required for maintenance of pumping plant . ( DE spanner set - 1 set,Ring spanner set - 1 set,Screw drivers - 2 Nos,Pliers - 1 No.Hammeres - 1 No.Pipe wrench 14" - 1 No.Screw wrench - 1 No.Crimping tool scissor type - 1 No.Tong tester - 1 No.Chain wrench 80 mm dia - 2 Nos.)
Supply of 5 ton capacity and 4.5 mt. lift chain pulley block
Supply of rubber resistance insulated sheets 2M x 1M x 25mm thick
Painting of entire installation with 2 coats of super enamel paint as per direction of Engineer-In-Charge of works.
GSM based Intelligent Remote Terminal Units (IRTU) with Analog and Digital parameters and features as specified to store and transmit data on GSM backbone to LMS. And also compatible to communication for two pumps.
GSM Based wireless communication system capable to transfer data from remote sites control station with antenna.
Supply ofIntelligent Energy Meter.
Supply ofValve actuator size 150mm.
Supply ofActuator panel
Supply of Isolation transformer
Supply of 2 Core 1.5sq.mm.cable
Supply of4 Core 2.5 sq.mm.cable
Supply of 10 Core 1.5 sq.mm.cable
Supply of1.5”PVC conduit Pipe.
Supply of1”PVC conduit Pipe.
AC& DC, Relay lugs etc.
Erection commissioning & customization of i- RTU/PLU & software & integration with existing SCADA Station.
Auto phase reversal unit 40-100H.P.
Electromagnetic Insertion type Flow Meters for line sizes 150mm
Supply of 125 KVA three phase rolling contact servo voltage stablizer of following capacity with input voltage range 300 to 480 with constant output of 415+/-1% complete in all respect ONAN Type.
Complete double loop earthing of system with copper plate and copper strips along with charcoal and salt with digging of pit complete in each and every respect as per latest is code (Using two earthing plate and other related material) for servo voltage stablizer
Installation, Testing & commissioning of The phase servo voltage stabilizer.
Wiring for light point, fan point etc. with 1.5 sq mm FR PVC insulated copper conductor single core cable in surface PVC conduit with piano type switch, phenolic laminated sheet, suitable size GI box, with earth wire of 1.5 sq mm FR PVC insulated copper conductor single core cable etc as required.
Wiring for circuit/submain alongwith earth wire with size of 2x2.5 sq. mm + 1x2.5 sq. mm earth wire of FR PVC insulated copper conductor single core cable in surface PVC conduit as required.
Wiring for circuit/submain alongwith earth wire with size of 2x4 sq. mm + 1x4 sq. mm earth wire of FR PVC insulated copper conductor single core cable in surface PVC conduit as required.
Supply and fixing of metal box of 180 rnmx100mmx160 mm deep on surface with suitable size phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 amp and 15x16 amp socket outlet and 15/16 amp piano type switch, connections, painting etc as required.
Supply and fixing of 6 way double door S.P.N. sheet steel, MCB DB, 240 V on surface complete with copper bus bar, neutral bus bar, earth bar, inter connections including earthing etc as required. (But without MCB/RCCB/Isolator)
Supply and fixing of 5 A to 32 A, 240 V, 10 KA, C serious MCB suitable for inductive load of following pole in the existing MCB DB complete with connection, testing etc as required.
Supply and fixing of double pole, 240 V, isolator ( 40amp. ) in the existing MCB DB complete with connection, testing etc as required.
Supply and fixing of 20 W LED tubelight complete in all respect (Bajaj/Philips or Equivalent make)
Supply in fixing of LED external lighting luminaires with mounting bracket etc. complete.
Charges of running through auto running system through Automation. for 6 months.
Liquid sodium hypo chloride
SAKLA NAND LAKHERA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .