| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.0 LAccepted-AOC 45 38 15 JAGANNADHAPURAM VISAKHAPATNAM 530 016 | VISAKHAPATANAM | ANDHRA PRADESH | 530016 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹30.3 L+₹3.3 L (12.3%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹31.6 L+₹4.6 L (17.1%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹32.5 L+₹5.5 L (20.4%)Rejected-Finance DOOR NO 50 13 27 14 FLAT NO 14 PADMAJA APARTMENTS SEETHAMMAPETA VISAKHAPATNAM 530016 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530016 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹34.0 L+₹7.0 L (25.9%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹34.0 L
EMD Value
₹67,940
Closing Date
26 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer P Navy Kalinga Visakhapatnam
Garrison Engineer P Navy Kalinga Military Engineer Services INS Kalinga PO Visakhapatnam 531 163
PROVN OF EQUIPMENT STORE AND AS AND AS TO SEWAGE LINE NEAR SHOPPING COMPLEX UNDER LBW AT NAVAL STATION BHEEMUNIPATNAM UNDER GE(P) NAVY KALINGA
2022_MES_504499_1
GE (P)/N/K/8867 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer P Navy Kalinga Visakhapatnam
Class D, Category a (i)
6 documents required · 6 mandatory
₹500
Garrison Engineer P Navy Kalinga Visakhapatnam
₹67,940
Yes
30 Mar 2022
29 Jan 2022
28 Feb 2022
29 Jan 2022
26 Feb 2022
12 Feb 2022
60 days
Amount
Excavation in trenches n. exc 1.5 mtr wide and n. exc 1.5 mtr in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, FRLS cable etc. n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in soft /loose soil complete all as specified and as directed.
M&L for PCC 1:4:8 type D2 (Using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n. exc 25 cm thick in soft /loose soil complete all as specified and as directed.
Removing excavated soil from site to a distance n.exc 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
M & L for treating the backfill in contact with the foundation at the rate of 7.5 Ltrs of anti termite emulsion per Sqm of vertical surface (area of sub structure in contact with backfill to be measured) complete all as specified and as directed.
M&L for treating the top surface of filled earth @ 5 ltrs of emulsion per Sqm of surface area complete all as specified and as directed.
M&L for treating the soil under plinth protection @ 5 ltrs of emulsion per Sqm of surface area complete all as specified and as directed.
M&L for treating the soil along with external perimeter of building @ 2.25 ltrs of emulsion per meter of the perimeter wall complete all as specified and as directed.
M & L reinforced cement concrete M-30 (Design Mix Concrete) using 20mm graded aggregate as in foundations, including rafts, footings, plinth beams, bases for columns, basement slab, under-reamed piles etc. complete all as specified and as directed.
M & L reinforced cement concrete M-30 (Design Mix Concrete) using 20mm graded aggregate as in columns, pillars, piers, posts etc complete all as specified and as directed.
M & L reinforced cement concrete M-30 (Design Mix Concrete) using 20mm graded aggregate as in lintel beams, roof beams and the like etc complete all as specified and as directed.
M & L reinforced cement concrete M-30 (Design Mix Concrete) using 20mm graded aggregate as in slab supported on walls and the like complete all as specified and as directed.
M & L reinforced cement concrete M-30 (Design Mix Concrete) using 20mm graded aggregate as in chajja etc complete all as specified and as directed.
Use and waste of form work to sides of concrete foundations, footings, bases of columns, rafts and raft beams, sided and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished flat surface of concrete completed all as specified and as directed.
Use and waste of form work to sides of columns and pillars for fair finished surfaces complete all as specified and directed.
Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for fair finished surfaces complete all as specified and as directed by the Engineer-in-Charge.
Use and waste of formwork to soffits of suspended slab such as roof slabs floor slab, landing and similar work not exceeding 200mm thick (Horizontal or sloping) in flat rough finished surface at concrete complete all as specified and as directed.
Use and waste of form work to fins, facia, chajjas, louvers, drops, parapets and railing etc and similar articles including edges complete all as specified and as directed.
M&L TMT bars 10mm dia and over, as reinforcement. cut to length, bent to shape required including cranking bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia complete all as specified.
M&L TMT steel bars 6mm to 8mm dia. cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia. or securing with clips or welded complete all as specified and as directed by the Engineer-in-Charge.
M & L for TMT steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Cutting opening through brick wall built in cement mortar for doors, windows and other openings or enlarging existing openings, converting windows into door opening or cutting out defective brick work for underpinning, including providing fixing and removing shoring, cleaning of bricks, removing surplus serviceable bricks, hardcore etc to store and rubbish not exc 50 mtrs complete all as specified and as directed.
M&L forming jambs etc to openings in CM 1:4 including cutting, toothing and properly bonding into old work, also facing jointing and pointing to match existing work complete
M&L Brick work with fly ash bricks straight or curved on plan exc 6.0 mtr mean radius built in cement mortar (1:6) complete all as specified and as directed
Earth filling in floors or pavings, using surplus earth from excavation, laid in layers n exc 15 cm thick spread, levelled and rammed including watering complete all as specified and as directed
M & L hardcore of broken stone or boulders of gauge n.exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and well rammed to a true surface, complete all as specified and directed.
M & L 75 mm thick PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in sub base/ floor, complete all as specified and directed.
M & L 25 mm thick PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in sub base/ floor, complete all as specified and directed.
M&L vitrified ceramic light shade tiles 10mm thick (Square/Rectangular) polished area of each tiles n.exc 0.36 Sqm as in floor etc. set and jointed in neat cement slurry and pointed in white and coloured cement to match the surface over and including screed bed layer 15 mm thick in CM 1:4 complete all as specified and as directed.
M&L vitrified ceramic light shade tiles 10mm thick (Square/Rectangular) polished area of each tiles n.exc 0.36 Sqm as in skirting etc. set and jointed in neat cement slurry and pointed in white and coloured cement to match the surface over and including 10 mm thick backing coat in CM 1:3 complete all as specified and as directed.
M & L rendering 10mm thick on internal surfaces of brick wall or concrete surface in cement mortar 1:6 finished even and fair without using extra cement complete all as specified and as directed.
M&L for Rendering in two coats with first coat of 10mm thick in CM 1:6 and second coat of 5mm thick duly mixing water proofing compound in CM 1:4 on fair faces of brick work or concrete surfaces finished fair and even without using extra cement complete all as specified and as directed. Note: Supply only WPC shall be measured and paid separately.
M&L for brushing neat cement slurry with 3.0 kg of cement per sqm complete all as specified and as directed.
M&L for 15mm thick screed bed on concrete surface in cement mortar 1:3 with water proofing compound before carrying out water proofing treatment over roof slab complete all as specified and as directed. Note: WPC will be measured and paid separately as supply only
M&L for APP based polymeric membrane minimum weighing 3 Kg/Sq.m. and minimum 3mm thick reinforced with polyester non wove fabric (weight not less than 150 gms/Sq.m.) laid on primed surface after applying a coat of blown bitumen 85/25 grade @ 1.20 Kg/Sq.m. over bitumen primer @ 0.50 Kg per Sq.m. by forced application, applying another coat of hot blown bitumen 85/25 grade @ 1.20 Kg per Sq.m. over water proofing membrane and applying a coat of solar reflective bituminous aluminium paint @ 0.10 Kg per Sq.m. all as per the manufacturers instructions, complete all as specified and directed by the Engineer-in-Charge.
M&L rendering 5mm thick in cement mortar 1:3 as in ceiling finishing the surfaces even and fair without using extra cement complete all as specified and as directed.
Supply only integral water proofing conforming to IS-2645-2003 complete all as specified.
M & L for preparation of new surfaces of walls and applying two coats of oil emulsion distemper over a coat of primer complete all as specified and directed.
M&L applying two coats of weather shield exterior emulsion paints over a coat of primer including preparation of new external wall surfaces complete all as specified and as directed.
M&L for preparation of new plastered surface and applying three coats of white wash on walls/Ceiling all as specified and directed
S & F powder coated anodised aluminium window and ventilator shutters, sliding type without sash bar, including necessary jointing cleats, glazing clips, rubber neoprene packing, anodised aluminium snap beading, roller, screws, anodised aluminium fittings such as suitable handle etc (thickness of powder coating not less than 50 micron) complete all as specified and as directed.
S&F 4.8 mm thick sheet glass, ordinary quality & glazing with neoprene gasket in square exc. 0.5 sqm in each pane complete all as specified.
S&F aluminium alloy wire cloth 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and as directed.
M&L 75mm thick PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in plinth protection/ sub base and paving finished cement concrete surfaces even and fair without using extra cement complete all as specified and as directed.
Excavation in trenches n. exc 1.5 mtr wide and exc. 1.5mtr in depth and n. exc 3.0 mtr in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 Sqm on plan and getting out in soft / loose soil complete all as specified and as directed.
S & F steel rolling shutter 1.00 mm thick of lath steel with ball bearing and safety lever lock mild steel, with 4 levers for rolling shutter as specified including top cover anchoring rod, hasp and staple and one coat of primer erected in position as indicated complete all as specified and as directed.
Supply only mild steel medium grade shaft pipe of 50mm dia as required for rolling shutter complete all as directed by Engr-in-Charge
Supply only guide channel, made out of MS sheet 3.15mm thick and 75mm wide complete all as directed by the Engr-in-Charge
S&F safety lever lock mild steel 4 levers for rolling shutters complete all as directed by Engr-in-Charge
S&F ball bearing for rolling shutters complete all as directed by Engr-in-Charge
S&F Factory made UPVC door frame made of UPVC extruded section having an overall dimension as below (tolerance+1mm) with wall thickness 2.00mm + 0.2mm+0.2mm, corners of the door frame to be jointed with galvanized bracket and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S tube of size 19 X 19 mm and 1mm + 0.1mm thickness and 3 nos stainless steel hinges fixed to the frame, extruded section profile size 48 X 40mm complete as per manufactures specifications/ instructions.
S&F 24mm thick factory made UPVC door shutters made of styles and rails of a UPVC hollow section of size 59 X 24mm and wall thickness 2mm+0.2mm with inbuilt edging on both sides. The styles and rails mitred and joined at the corners by means of MS Galvanized / plastic brackets of size 75X220mm having wall thickness 1.00 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised MS tube of size 20 x 20 mm and 1 mm + 0.1mm wall thickness. The lock rail made up of H section , UPVC hollow Section of size 100x24mm and 2mm+0.2mm wall thickness fixed to shutters styles by means of plastic/galvanized M.S U cleats. The shutter frame filled with a UPVC multi chambered single panel of size not less that 620mm having over all thickness of 20mm and 1mm+0.1mm wall thickness. The panels filled vertically and the tie bar at two places by inserting horizontally 6mm galvanized M.S rod and fastened with nuts and washers, complete as per manufactures specifications/instructions.
S&F 5mm thick tinted glass and square exc. 0.5 Sq.m. in each pane fixed to PVC/UPVC frame work complete all as specified and as directed by the Engineer-in-Charge
S&F Frameless toughened glass door with sliding shutters (02 Nos), shutter 12MM thick factory toughened plain sheet glass , not exc 2.00 SQM, using the stainless steel fittings of polished chrome finish, in each shutter (stainless steel finish for handles) including cutting necessary holes and cutouts complete all as specified and as directed by Engr-In-charge. (a) Corner lock patches with EPC and strike plate XL-C-4011A : 01 No (for openable shutter) (b) Floor spring 90 degree open(EN4) : 01 No (for openable shutter) (c) Top patches XL-C 4012 : 01 No (for openable shutter) (d) Bottom patches XL-C 4013 : 01 No (for openable shutter) (e) Top pivots AL-C 4014 : 01 No (for openable shutter) (f) 450mm long H -Type handles 25mm dia of grade SS-304, XL-C-3003A : 01 No (01 Set for openable shutter)
S & F powder coated aluminium frame for doors, windows, ventilators with one or more rebates including jointing cleat for fixing etc, (minimum thickness of powder coating 50 micron) complete all as specified and as directed.
Excavation over areas n.exc 1.5 m deep and getting out in soft/ loose soil complete all as specified and as directed.
Excavation over areas exc 1.5 mtr deep but n.exc 3.0 mtr deep and getting out in soft/ loose soil complete all as specified and as directed.
M&L PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested for 150 mm dia drain pipe complete all as specified and directed
M&L for underground drainage double wall HDPE pipe 150 mm dia SN4 conforming to IS:16098 (Part-II) single socketed in any length laid in trenches or floors etc complete all as specified and directed.
M&L Brick work with fly ash bricks straight or curved on plan exc 6.0 mtr mean radius built in cement mortar (1:4) complete all as specified and as directed
Taking down cement plaster of any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc built in cement mortar complete all as specified and as directed by the Engineer-in-Charge.
M&L precast reinforced cement concrete 1:2:4 type B-1 (Using 20mm graded stone aggregate) as in landings, cover slab (for manhole), chullah hood, chajjas, water trough, mangers, shelves etc and similar articles with plain faces set in CM 1:6 complete all as specified and as directed.
S&F Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wires etc; flat iron fillets (for securing wire mesh) complete all as specified and as directed.
Demolition of Brick work or stone boulders masonry built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and as directed
M&L for Cutting into existing manholes for connecting new drains, making good to pipe & rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete1:2:4 type B-1 smooth finished and reforming benching as required for 150 mm bore drain pipe complete all as directed.
Material and labour for point wiring for one light controlled by 1 one way switch with 1.5 Sqmm PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable 1100 Volts grade drawn through and including 20 mm dia (medium grade) rigid non metallic PVC concealed conduit along with 1.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and to be terminated in and including pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mmX300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet cover for mounting switches, sockets, fan regulators etc including testing on completion complete including cutting chases for concealed conduit pinning in making good to facing and pointing in using cement mortar 1:3 and making good disturbed surface all as specified and as directed.
All as per Item no 66 here-in-before but for one light point controlled by two 2 way switch all as specified and as directed.
All as per Item no 66 here-in-before but for one fan /E Fan point controlled by 1 one way switch and regulator all as specified and as directed.
All as per Srl Item No. 66 here-in-above but for One socket outlet point 3 pin 5 A on independent board.
All as per Srl Item No. 66 here-in-above but for One switch socket outlet point 5 A on same board with other switches
All as per Srl Item No. 66 here-in-above but for one switch socket out let for 16 Amps 3 & 5 pin on independent board with 4.0 Sqmm cable and 4.0 Sqmm earth wire.
Supply and fixing switch piano flush button single pole one way 5 amps all as specified and as directed
S&F switch piano flush type single pole two way 5 Amps, 230 Volts, 50 Hz complete all as specified and as directed by the Engineer-in-Charge.
S&F switch socket outlet 5 pin 5 amp flush type with including switch all as specified and as directed.
Supply and fixing switch socket combination 2 in 1 3 pin, 5 and 15 amp flush type all as specified and as directed
Supply and fixing ceiling rose surface bakelite three terminals all as specified and as directed.
Supply and fixing fan regulator electronic deluxe rotary step type complete all as specified and as directed.
M&L for concealed Sub main wiring with two run of 6.00 Sqmm (nominal cross-sectional area) FRLS PVC insulated and unsheathed 1100 V grade multi stranded copper conductor single core cable drawn through and including PVC medium grade conduit of 25 mm dia with all fittings and accessories concealed in walls, floors and ceilings complete including one run of FRLS PVC insulated and unsheathed single core multi stranded copper conductor cable of size 6.00 Sqmm as earth continuity conductor connected to common earth and earth dolly for main DB to sub DB including cutting chases pinning in making good to facing and pointing in using cement mortar 1:3 to the ends complete all as specified and as directed. NOTE: 3 runs of 6 Sqmm and one run of PVC concealed conduit 25mm dia will be measured as one unit i.e. RM
Supply and fixing sheet metal enclosure for MCCB, DBs, phosphatised, Powder coated , Triple Pole and Neutral (TPN), suitable for 4 way, Double door 415 Volts all as specified and as directed .
Supply and fixing sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , single pole and neutral (SPN) 240 Volt , double door, suitable for 8 way with din rail earth and neutral bar all as specified and as directed.
Supply and fixing MCB Four Pole (FP) C curve 10kA breaking capacity of 63 amps, 415 Volts in proper position all as specified and as directed.
Supply and fixing MCB Single Pole (SP) C curve 10kA breaking capacity of 6 to 32 amps, 240 Volts in proper position all as specified and as directed.
S&F in proper position MCB Double Pole of capacity 40 amps, 240 Volts C-series with 10kA breaking capacity all as specified and as directed.
S&F single pole and neutral enclosure with two pin earth plug with 01 Nos of MCB DP 20 Amps 'C' series complete all as specified and as directed.
Supply and fixing indoor luminaries decorative batten for wall/ceiling mounting box type Extruded aluminium housing ,PC Diffuser, energy efficient saving LED BATTEN LIGHT 20W, 230 V, 50 HZ, slim integrated design easy install including twin twisted copper conductor flexible wire from ceiling rose to connector all as specified and as directed. (CG Cat Part no. CCS-100-20-65-HL2-DP-NWH or equivalent as approved by GE)
Supply and fixing mounting luminaries LED downlighter of 30 watt white shape of square 1'x1' feet complete all as specified and as directed. Make : CG Cat No. CDR-209-18-30-SL-NWH or equivalent as approved by GE
Supply and fixing on wall security LED light luminaries fitting 1X25 W and including cable for connection from ceiling rose with 1.5 Sqmm PVC insulated stranded copper conductor (FRLS) cable including 25 mm GI bracket medium grade 1.5 m long bent to shape including bolt, nut,washer,clamp etc all as specified and as directed by the Engineer-in-charge.
S&F Ceiling fan 230 Volts 1200mm sweep, 5 STAR rating, BLDC 32W decorative blades metallic white with and including fan regulator, clamp and hook at proper position complete incl all accessories.
Supply and fixing AC three phase static Electronic KWH energy meter of accuracy class 1.0, 240 volt, 50Hz, with bakelite LCD Display, of rating 10-60A with transparent hinged type Box with six month History of energy in KWH meter all as specified and as directed by the Engineer-in-Charge.
Material and labour for XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) with stranded aluminium conductor 1100 volts grade, cross sectional area 25 Sqmm 4 core laid in trench /poles/on wall and all as specified and as directed
Material and labour for sand cushioning for protection of underground cable consolidated and compacted with clean dry sand all as specified and as directed (Note : Compacted thickness shall only be measured and paid)
Supply and lay bricks common burnt clay building bricks sub-class B of size 230x115x75 complete all as directed by Engr-in-Charge.
M&L for Drilling of hole horizontally 80/40 mm dia below the road for providing casing pipe of cable protection by using mechanical /hand drill all as specified and as directed.
Material and labour for galvanized iron tubing 25mm bore light grade with all fitting for protection of UG cable, laid in trenches/wall/floor incl necessary clamp, bolt/nut if any all as specified and as directed. (Note: Excavation , earth work shall be measured and paid separately)
S&F and install air cooled wall split units indoor/outdoor air conditioner 3 star rated electric driven single phase complete with cordless remote control unit of capacity 2.0 TR
Supply and fix voltage stabilizer 5 KVA, 240 Volts 50 Hz complete all as specified and directed by Engr-in-Charge
M&L for earthing complete with galvanized steel earth plate electrode 600x 600 x 6.3 mm buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to galvanized earth lead wire 4mm dia (upto 7.5 m in length from earth plate) by means of galvanized iron or steel bolts, nuts, check nuts and washers, and connected to equipments as directed, including funnel with GI med grade watering pipe 20mm bore, wire mesh charcoal or coke and common salt in alternate layers, of 15cm compacted thickness all around the earth electrode, with concrete pit in PCC 1:3:6 type C-1, 50mm thick pre cast RCC 1:2:4 type B1 cover slab reinforced with 8mm dia reinforced bar 15cm C/C and earth lead handle protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I and as directed
S V S ENTERPRISES
M S G CONSTRUCTIONS
P SRINIVASA RAO
SWATHI CONSTRUCTIONS
POTHINA SAMBAMURTHY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .