Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹14.4 L+₹2.0 L (16.3%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
₹15.5 L
EMD Value
₹38,704
Closing Date
21 May 2025, 2:00 pmClosed
Executive Engineer
Office of the Executive Engineer,PH Division, Kochi-16
DEPOSIT Kochi Corporation Replacing old and damaged 100mm AC pipeline with 160mm PVC pipeline along Church road Thykkoodam and allied works
2025_KWA_764434_1
WRD/KWA-CE(CR)/TR/4767/2025
Open Tender
Civil Works - Water Works
Item Rate
90 days
KMC area
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
₹38,704
21 Jun 2025
14 May 2025
22 May 2025
14 May 2025
21 May 2025
14 May 2025
14 May 2025 - 21 May 2025
Amount
Working Charges
15.43.2:Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road
16.83:Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
2.16.1:Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete (Measurements to be taken of the face area timbered).Depth not exceeding 1.5m
100.7.1:Bailing out water with 5HP engine and pump set including conveyance to the site, erecting, dismantling and taking back of engine and pump, cost of fuel lubricating oil and other stores pay of staff etc., complete.
100.98.1008:Engaging Coolie.
100.9.11:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 160 mm nominal outside diameter pipes.
100.9.7:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 75 mm nominal outside diameter pipes.
100.9.6:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 63 mm nominal outside diameter pipes.
OD237512/2024-2025:Interconnecting new 160mm PVC pipe with 160mm PVC pipe using 160mm PVC Tee, suitable fittings et. complete as per the direction of departmental officers.
OD237514/2024-2025:Interconnection from new 160mm PVC pipe to existing branch line of 63/75/90/110mm PVC pipe by using 160x63mm PVC saddle clamp and suitable specials etc complete as per the direction of departmental officers
OD13395/2025-2026:Taking interconnection from existing 75/63mm PVC pipe to the new 63mm PVC pipe using suitable fittings, etc. complete as per the direction departmental officers.
OD13396/2025-2026:Taking interconnection from existing 90mm PVC pipe to new 75mm PVC pipe using suitable fittings, etc. complete as per the direction departmental officers.
OD237513/2024-2025:Shifting the public hydrants/ house connections with 3/4" UPVC/ASTM pipe and specials up to 2m from the existing line to the newly laid 160mm PVC pipes at different places as per the direction of department officer.
OD10378/2025-2026:Shifting the public hydrants/ house connections with 3/4" UPVC/ASTM pipe and specials above 2m from the existing line to the newly laid 160mm PVC pipes at different places as per the direction of department officer. (cost including concrete drain demolishing for drain crossing, etc.)
OD13397/2025-2026:Shifting the public hydrants/ house connections with 3/4" UPVC/ASTM pipe and specials from the existing line to the newly laid pipes( Diameter upto 110mm ) at different places as per the direction of department officer.
100.31.1.4:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 150mm diameter, Class I.
100.31.1.2:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 100mm diameter, Class I.
15.60:Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved
16.79:Providing , laying spreading and compacting graded stone aggregate ( size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub - base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer - in- Charge.
16.84:Laying old cement concrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost.)
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
OD237511/2024-2025:Discarding existing 100mm AC pipe by cutting and endcapping both sides with 100mm CID joint, suitable specials etc. including all materials, labour charges etc. complete as per direction of departmental officers
OD10694/2025-2026:End capping both sides of existing 90mm PVC pipe by cutting and fixing using suitable specials etc. complete as per direction and specifications of departmental officers.
OD10698/2025-2026:Interconnecting existing 100mm AC pipe with 90mm PVC pipe using 100mm CID joints, 110x90mm PVC Reducer, 90mm PVC pipe, etc. complete as per the specification and direction of departmental officers
OD10703/2025-2026:Interconnection from existing 160mm PVC pipe to existing branch line of 160mm/110mm PVC pipe by using 150x80mm MS saddle clamp and suitable specials etc. complete as per the direction and specifications of departmental officers.(Cost including all material charges, Bituminous cutting, Earth work excavation, demolishing CC, providing WWM, Concreting charges etc)
100.59.3:Restoring the road surfaces by providing and laying factory made cold bitumen-aggregate pot-hole repair mix in two layers of 25mm thick (total 50mm thick), by cleaning the surface with brooms etc. to remove dust/debris/water etc, placing the premix, compacting properly with hand-rammer etc. complete, including traffic control, providing caution boards and as per direction of Engineer-in-charge for road restoration works in pipeline leak sites.
OD13555/2025-2026:Towards the charges for conveying 160mm PVC pipe from Kadavanthra office compound to Church road including the hire charges for vehicle, labour, material loading and unloading charges, stacking etc.. complete as per the direction of department officer
Cost of materials
100.98.460:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 150mm.
100.98.458:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 100mm.
OD237515/2024-2025:Supply of 150mm CID joint with accessories.
OD237517/2024-2025:Supply of 160mm PVC coupler.
OD13577/2025-2026:Supply of 100mm PVC one side flanged tail piece for fixing D/F valve, including all materials, etc complete as per the direction of departmental officers
OD13578/2025-2026:Supply 110mm CIR Joint including all accessories
100.98.211:Supply of PVC Pipe, 6kg/cm2, 63mm Dia.
100.98.212:Supply of PVC Pipe, 6kg/cm2, 75mm Dia.
OD237518/2024-2025:Supply of 160mm PVC end cap.
OD237516/2024-2025:Supply of 150mm DI tail piece. (one side flanged)
k n babu (BID ID -2213917)
Bidder Name
k n babu
udayakumar
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .