| 1 | L1₹56.3 LAccepted-AOC NO 24 54 21 5 LIG 408 VUDA COLONY VINAYAKA NAGAR GAJUWAKA VISAKHAPATNAM 530026 | VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | ₹56.3 L | L1 | Accepted-AOC Lowest Bid Accepted |
| 2 | L2₹56.5 L+₹25,581.50 (0.45%)Rejected-Finance | ₹56.5 L+₹25,581.50 (0.45%) | L2 | Rejected-Finance Not Being Lowest Bidder |
| 3 | L3₹58.3 L+₹2.0 L (3.63%)Rejected-Finance | ₹58.3 L+₹2.0 L (3.63%) | L3 | Rejected-Finance Not Being Lowest Bidder |
| 4 | L4₹63.2 L+₹7.0 L (12.4%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | NTR | ANDHRA PRADESH | 520001 | ₹63.2 L+₹7.0 L (12.4%) | L4 | Rejected-Finance Not Being Lowest Bidder |
| 5 | L5₹63.8 L+₹7.6 L (13.5%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | ₹63.8 L+₹7.6 L (13.5%) | L5 | Rejected-Finance Not Being Lowest Bidder |
| Sl No | Description | Qty | Unit | M B CONSTRUCTIONS L2 | RAGHU RAMA PANDA L5 | JAYAM BUILD CONSTRUCTIONS L3 | sai ganesh enterprises L4 | K & K CONSTRUCTIONS L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | SCHEDULE 'A' PART-I [B/R Works]:
Taking down chowkats or frames with shutters (without taking off shutters from the frame) not exc 1.5 Sqm each complete all as specified and directed. | 2 | EACH | 250 ₹500 | 259 ₹518 | 499 ₹998 | 140 ₹280 Lowest | 150 ₹300 |
| 2.00 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) not exc 1.5 Sqm but not exc 4.0 Sqm each complete all as specified and directed. | 50 | EACH | 300 ₹15,000 | 322 ₹16,100 | 550 ₹27,500 | 160 ₹8,000 | 150 ₹7,500 Lowest |
| 3.00 | M & L for Powder coated aluminium (minimum thickness of powder coating 50 micron) for doors, windows & ventilators, partitions with frames and shutters fully or partly glazed, sliding / openable / fixed with extruded aluminium sections not less than 1.5mm thick and powder coating not less than 60 micron thick including necessary jointing cleats, rubber beading, neoprene packing, aluminium snap beading, screws, powder coated aluminium fittings such as handles, aluminium butt hinges, aluminium tower bolts, stainless steel friction hinges, locking arrangements, etc complete all as specified and directed by the Engineer-in-Charge:-
[Notes:
[a] The size of aluminium extruded sections shall conorm to Designation 63400 and shall be as specified in relevant IS code and as specified in MES Schedule Part-I.
[b] Panel inserts such as Glass / Particle board / Gauze shall be measured and paid seperately.
[c] Weight of aluminium sections shall only be accounted for payment purpose.
[d] Quoted rate is deemed to be inclusive for necessary jointing cleats, rubber beading, neoprene packing, aluminium snap beading, screws, powder coated aluminium fittings such as handles, butt hinges, tower bolts, SS friction hinges, locking arrangements, etc | 1,740 | KG | 651 ₹11,32,740 | 619 ₹10,77,060 | 600 ₹10,44,000 | 650 ₹11,31,000 | 595 ₹10,35,300 Lowest |
| 4.00 | S & F 5.0mm thick sheet glass, ordinary quality and glazing with oil putty in squares exceeding 0.5 Sqm in each pane fixed to aluminium joinery complete all as specified and directed. | 100 | SqM | 1,000 ₹1,00,000 | 997 ₹99,700 | 1,900 ₹1,90,000 | 620 ₹62,000 Lowest | 800 ₹80,000 |
| 5.00 | S & F Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as directed | 100 | SqM | 650 ₹65,000 | 529 ₹52,900 | 1,100 ₹1,10,000 | 600 ₹60,000 | 450 ₹45,000 Lowest |
| 6.00 | M & L for 6mm thick Aluminium Composite Panel with 0.5mm thick prefinished cover sheet heat bonded (laminated) to core made of polyethylene plastic material on either side of approved colour complete all as directed | 25.2 | SqM | 1,300 ₹32,760 Lowest | 2,599 ₹65,494.8 | 1,800 ₹45,360 | 4,000 ₹1,00,800 | 2,000 ₹50,400 |
| 7.00 | M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing with neat cement slurry with 3.0 Kg of cement per Sqm area, rendering 10mm thick in cement mortar 1:4 duly mixed with and including water proofing compound on concrete surfaces finished even and smooth without using extra cement and laying Polymeric water proofing membrane of weight not less than 3.00 Kg per Sqm reinforced with polyester non-woven fabric of weight not less than 150 Grams per Sqm, by torch application with side over lap of 100mm & end over lap of 150mm & tucked into the chases on vertical surfaces by thermo fusion including applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sqm including taking down existing Roof Treatment of any description and removing rubbish outside MD land complete all as specified and as directed. | 300 | SqM | 815 ₹2,44,500 | 907 ₹2,72,100 | 1,300 ₹3,90,000 | 650 ₹1,95,000 Lowest | 850 ₹2,55,000 |
| 8.00 | S & F 75mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls/ceiling including taking down old pipes with fittings complete all as specified and directed. | 30 | RM | 299 ₹8,970 | 322 ₹9,660 | 355 ₹10,650 | 185 ₹5,550 Lowest | 206 ₹6,180 |
| 9.00 | S & F 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls/ceiling including taking down old pipes with fittings complete all as specified and directed. | 112 | RM | 449 ₹50,288 | 439 ₹49,168 | 500 ₹56,000 | 285 ₹31,920 Lowest | 300 ₹33,600 |
| 10.00 | M & L for 75mm bore PVC (SWR) bends any radius with access door complete all as specified. | 8 | EACH | 175 ₹1,400 | 322 ₹2,576 | 390 ₹3,120 | 185 ₹1,480 | 120 ₹960 Lowest |
Tender Value
₹66.4 L
EMD Value
₹1.3 L
Closing Date
4 Dec 2025, 6:00 pmClosed
Col Shinde SS, Commander Works Engineer
Commander Works Engineers, Station Road, Visakhapatnam - 530 004
SPECIAL REPAIRS TO BUILDING NO. 551 02 OXYGEN FILLING AND COMPRESSOR WORKSHOP AT TPW-II COMPLEX, NAD INSIDE NAVAL DOCKYARD UNDER GE NB VISAKHAPATNAM
2025_MES_738239_1
82619/E8
Open Tender
Civil Works
Item Rate
180 days
Visakhapatnam
As per NIT
9 documents required · 9 mandatory
₹1,000
Garrison Engineer Naval Base
₹1.3 L
Yes
16 Apr 2026
6 Nov 2025
8 Dec 2025
6 Nov 2025
4 Dec 2025
27 Nov 2025
6 Nov 2025 - 13 Nov 2025
Amount
SCHEDULE 'A' PART-I [B/R Works]: Taking down chowkats or frames with shutters (without taking off shutters from the frame) not exc 1.5 Sqm each complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frame) not exc 1.5 Sqm but not exc 4.0 Sqm each complete all as specified and directed.
M & L for Powder coated aluminium (minimum thickness of powder coating 50 micron) for doors, windows & ventilators, partitions with frames and shutters fully or partly glazed, sliding / openable / fixed with extruded aluminium sections not less than 1.5mm thick and powder coating not less than 60 micron thick including necessary jointing cleats, rubber beading, neoprene packing, aluminium snap beading, screws, powder coated aluminium fittings such as handles, aluminium butt hinges, aluminium tower bolts, stainless steel friction hinges, locking arrangements, etc complete all as specified and directed by the Engineer-in-Charge:- [Notes: [a] The size of aluminium extruded sections shall conorm to Designation 63400 and shall be as specified in relevant IS code and as specified in MES Schedule Part-I. [b] Panel inserts such as Glass / Particle board / Gauze shall be measured and paid seperately. [c] Weight of aluminium sections shall only be accounted for payment purpose. [d] Quoted rate is deemed to be inclusive for necessary jointing cleats, rubber beading, neoprene packing, aluminium snap beading, screws, powder coated aluminium fittings such as handles, butt hinges, tower bolts, SS friction hinges, locking arrangements, etc
S & F 5.0mm thick sheet glass, ordinary quality and glazing with oil putty in squares exceeding 0.5 Sqm in each pane fixed to aluminium joinery complete all as specified and directed.
S & F Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as directed
M & L for 6mm thick Aluminium Composite Panel with 0.5mm thick prefinished cover sheet heat bonded (laminated) to core made of polyethylene plastic material on either side of approved colour complete all as directed
M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing with neat cement slurry with 3.0 Kg of cement per Sqm area, rendering 10mm thick in cement mortar 1:4 duly mixed with and including water proofing compound on concrete surfaces finished even and smooth without using extra cement and laying Polymeric water proofing membrane of weight not less than 3.00 Kg per Sqm reinforced with polyester non-woven fabric of weight not less than 150 Grams per Sqm, by torch application with side over lap of 100mm & end over lap of 150mm & tucked into the chases on vertical surfaces by thermo fusion including applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sqm including taking down existing Roof Treatment of any description and removing rubbish outside MD land complete all as specified and as directed.
S & F 75mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls/ceiling including taking down old pipes with fittings complete all as specified and directed.
S & F 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls/ceiling including taking down old pipes with fittings complete all as specified and directed.
M & L for 75mm bore PVC (SWR) bends any radius with access door complete all as specified.
M & L for 110mm bore PVC (SWR) bends any radius with access door complete all as specified.
S & F in repairs Vitreous China Ware Wash Hand Basin, White, Flat Back of size 550mm X 400mm including 32mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand, 32mm bore PVC flexible Waste Pipe, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc. complete all as specified and as directed.
S & F in repairs Vitreous China Wash Down Water Closet [Pedestal pattern] of size 560x440x395mm or nearest size, White, including flush pipe of polyethylene of low or high density of PVC, 32mm dia, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc. including brackets and connections to pipe and flush pipe including plastic water closet seat back closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device and 'P' or 'S' trap including low PVC level flushing cistern 10 lit capacity complete all as specified and as directed.
S & F Rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) 1000 litres capacity, triple layered, hoisted and fixed in position including 20mm dia PTMT ball valve including dismantling existing RCC tank and removing debris outside MD land complete all as specified and directed.
Supplying and fixing of 16mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings concealed in walls / ceiling or laying in floors including taking up or down old GI tubing of 15mm dia complete all as specified and directed.
Supplying and fixing of 20mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings concealed in walls / ceiling or laying in floors including taking up or down old GI tubing of 20mm dia complete all as specified and directed.
Supplying and fixing of 25mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings concealed in walls / ceiling or laying in floors including taking up or down old GI tubing of 25mm dia complete all as specified and directed.
Supplying and fixing of 32mm bore CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings concealed in walls / ceiling or laying in floors including taking up or down old GI tubing of 32mm dia complete all as specified and directed.
M & L for coloured joint free Non skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of tile laid over and including 15mm thick screed bed in CM 1:6 including dismantling existing tiles complete all as specified and directed.
M & L for coloured joint free Non skid Ceramic tiles 7 to 8 mm thick light shade (square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of tile laid over and including 15mm thick screed bed in CM 1:6 including dismantling existing tiles complete all as specified and directed. [Note: The tile joint shall be kept as 3mm using tile spacers and masking tape shall be provided before applying of the epoxy grout and the surplus grout materials shall be thoroughly cleaned immediately]
M & L for coloured joint free Non skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in vertical surfaces as in skirting / dados set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of tile laid over and including 10mm thick backing coat in CM 1:4 including dismantling existing tiles complete all as specified and directed. [Note: The tile joint shall be kept as 3mm using tile spacers and masking tape shall be provided before applying of the epoxy grout and the surplus grout materials shall be thoroughly cleaned immediately]
M & L for coloured Glazed ceramic tiles of size 450x350x7mm thick as in vertical surfaces such as skirtings, dados and risers of steps, etc. set and jointed in neat cement slurry and pointed in white or colour cement to match with shade of tiles laid over and including 10mm thick backing coat in CM 1:4 including dismantling existing tiles complete all as specified and directed. [Note: Rate quoted is deemed to include for cutting for offsets etc]
M & L for 25mm thick, PCC 1:2:4, Type B-0, using 12.5mm graded stone aggregate as in sub base of floors / roof treatment as complete all as specified and as directed.
Taking down cement plaster on brick work or stone masonry walls, etc including raking out joints, hacking for key, scrubbing down with water, etc complete all as directed.
M & L for rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished even and smooth with out using extra cement complete all as specified and directed.
M & L for rendering in two layers comprises of 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces finished with 5mm thick in CM 1:4 duly mixed with and including cement water proofing compound as per manufacturers instructions, finished even and smooth with out using extra cement complete all as specified and directed.
M & L for rendering 5mm thick in CM 1:3 on fair faces of ceiling surfaces, finished even and smooth with out using extra cement complete all as specified and directed.
S & F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof overing/cladding to wall, fixed with self tapping screws including dismantling old heeting of any pattern complete all as specified and directed.
S & F in repairs rolled mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 including dismantling old mild steel work complete all as directed
M & L for brick work with fly ash bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 using old size bricks including demolition of old brick work complete all as specified and directed.
M & L for providing Precast RCC 1:2:4, Type B-1, using 20mm graded stone aggregate as in Landings, Cover Slabs [for manholes etc], Chullah Hoods, Chajjas, Water Troughs, Mangers, Shelves and similar articles with plain faces set in cement mortar 1:4 including demolition of existing cement concrete and removing debris outside MD land complete all as specified and as directed.
M & L for High Strength Corrosion Resistant Deformed TMT Bars of 10mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
S & F 110mmb ore PVC [SWR] vent cowl
M & L for 100mm thick, PCC 1:3:6, Type C-2, using 40mm graded stone aggregate as in flooring / hardstanding / path complete all as specified and as directed.
Demolition of Unreinforced Cement Concrete of any description and in any position not otherwise specifically provided for and removing rubbish off the primises complete all as specified and as directed.
S & F Steel rolling shutters of thickness of laths 1.25mm, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated, push pull or manual type including taking down existing rolling shutters complete all as directed.
M & L for preparation of old decorated surfaces of ceiling by brooming down, brushing and applying one coat of white wash complete all as spcified and directed.
M & L for complete removal of existing treatment of any description on wall surfaces by using vaccume based sanding machine, removal of nails and applying two coats of Acrylic Washable Distemper by using auto roller/ airless sprayer over one coat of alkali resistant primer on wall surfaces over Cement based Wall Care Putty of suitable thickness on walls by using multipurpose mixture for proper mixing of putty and putty sprayer for application of putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces complete all as specified and as directed. [Note:- The contractor shall carryout Distempering & allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Distempering & allied works through their authorised applicators before commencement of the work to GE for approval.]
M & L for newly plastered wall surfaces by using vaccume based sanding machine, removal of nails and applying two coats of Acrylic Washable Distemper by using auto roller/ airless sprayer over one coat of alkali resistant primer on wall surfaces over Cement based Wall Care Putty of suitable thickness on walls by using multipurpose mixture for proper mixing of putty and putty sprayer for application of putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces complete all as specified and as directed. [Note:- The contractor shall carryout Distempering & allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Distempering & allied works through their authorised applicators before commencement of the work to GE for approval.]
M & L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directetd.
M & L for preparation of old painted steel surfaces of any description, not otherwise described over 10cm in width or girth and applying one coat of synthetic enamel paint over complete all as specified.
M & L for preparation of new or previously untreated steel surfaces of any description, not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
M & L for Complete removal of existing treatment of any description on walls/ ceiling, pillasters, bands, borders, soffits of chajjas and projections by using vaccume based sanding machine, removal of nails including rubbing with sand paper to obtain a smooth surfaces and applying Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] by using auto roller/ airless sprayer over a Coat of Exterior Primer over Cement based Wall Care Putty of suitable thickness [primer and putty shall be of same manufacturer as that of exterior emulsion paint] by using multipurpose mixture for proper mixing of putty and putty sprayer for application of putty complete all as specified and as directed. [Note:- The contractor shall carryout Weather proof Exterior Emulsion Painting under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Weather proof Exterior Emulsion Painting through their authorised applicators before commencement of the work to GE for approval.
M & L for preparation of newly plastered surfaces of walls/ ceiling, pillasters, bands, borders, soffits of chajjas and projections by using vaccume based sanding machine, removal of nails including rubbing with sand paper to obtain a smooth surfaces and applying Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] by using auto roller/ airless sprayer over a Coat of Exterior Primer over Cement based Wall Care Putty of suitable thickness [primer and putty shall be of same manufacturer as that of exterior emulsion paint] by using multipurpose mixture for proper mixing of putty and putty sprayer for application of putty complete all as specified and as directed. [Note:- The contractor shall carryout Weather proof Exterior Emulsion Painting under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Weather proof Exterior Emulsion Painting through their authorised applicators before commencement of the work to GE for approval.
S & F in repairs Ball Valves, 20 mm Bore, high pressure of PTMT (Minimum weight 200 gms) with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe etc complete all as specified and as directed.
S & F in repairs 15mm bore bib tap fancy type Chromium plated capstan head, screwed down, screwed for 15mm dia bore iron pipe complete all as specified and directed. [Make shall be Jaquar of Cat Part No. ACN-CHR-5041N or its equivalent]
S & F Sawn neck Pillar Taps, cast copper alloy, Chromium Plated, Fancy Type, 15 mm dia, with capstan head, screwed down high pressure with or with out lettered "Hot" or "Cold" with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as directed. [Make shall be JAQUAR of Cat No. CQT 23167B or its equivalent]
S & F in repairs 15mm bore, angular stop cock with wall flange, cast copper alloy, chromium plated fancy type with crutch or butterfly handle, screwed down screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. [Make shall be Jaquar of Cat Part No. KUP-35053PM or its equivalent]
S & F fancy type Chromium plated two way bib taps, cast copper alloy, with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule with flanges complete all as specified and directed. [Make shall be Jaquar of Cat Part No. KUP-35041PM or its equivalent]
S & F in repairs Health faucet (ABS body) mild steel chromium plated suitable for 15mm dia pipe with 1.25m Long flexible tube and ABS wall hook including making connections and fixed in position complete all as directed.
S & F in repairs PVC (SWR) floor trap of 75mm dia outlet with grating including jointing with solvent cement of outlet complete all as directed
S & F in repairs 75mm dia Stainless steel grating fixed with white cement complete all as directed
Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for and removing debris outside MD land complete all as specified and as directed.
M & L for applying 2 coats of two component solvent free , moisture insenstive epoxy resin coating it should achieve Compressive Strength of >70 MPa after 14days, having pot life Pot life, minutes at 27⁰C, 100 g >40 mass.The product shall have a minimum pot life of 120 Min at 35°C and an open time of atleast 4-6 Hours @ 30°C.It shall develop a minimum compressive strength of 40 MPa and a bond Strength of 11 MPa of TM bond EP. Before applying coating surface should be cleaned from dirt, fungus and all foreign material complete all as specified and directed by Engr-in-charge.
M & L for treating the existing pipe penetrations using non-shrink, free flowing, cementitious grout. The compressive strength of the grout must exceed 50 N/mm2 at 7 days and 60 N/mm2 at 28 days. The flexural strength of grout must exceed 9N/mm2 @ 28 days. Fresh wet density of the mixed grout must exceed 2150 kg/m3 of Maxgrout PF. Further flashing the area using solvent based UV resistant polyurethane based waterproofing material having minimum tensile strength on 4 N/mm2 and minimum elongation of 800% complete all as specified and directed by Engineer-in-charge.
M & L on dilapidated reinforcement encased in concrete for providing and applying alkaline based Anti-oxidizing compound for steel structure conforming to ASTM D 1748-10(2015) after cleaning loose scale or oxidized chips from bars .The material to be applied on the rusted metal using brush. Allow it to react for 16 to 24 hrs, pH Value : Alkaline (9.5 - 10) and afterwards wire brushing the surface. Clean with dry cloth before application of protective Ferro mono primer coating etc. complete all as specified and directed by Engr-in-charge.
M & L for applying 10mm shear thinning fibre reinforced polymer modified , impermeable to aggressive elements, dual shrinkage compensated, cementitious repair mortar with alkali resistant synthetic fibres for exceptional resistance cracking complies ASTM C 109 with flexural strength ASTM C 348 @ 7 days meeting 7N/sqmm, tensile strength @ 7days (ASTM C 307)> 3 N/sqmm, compressive strength of 35MPa at 7 day and 45MPa at 28 days, at the outer or inner RCC , Versatile having specific gravity of 1.02 cement sand can be used for finishing purpose of Matret patch up complete all as specified and directed by Engr-in-charge.
M & L for applying 20mm shear thinning fibre reinforced polymer modified , impermeable to aggressive elements, dual shrinkage compensated, cementitious repair mortar with alkali resistant synthetic fibres for exceptional resistance cracking complies ASTM C 109 with flexural strength ASTM C 348 @ 7 days meeting 7N/sqmm, tensile strength @ 7days (ASTM C 307)> 3 N/sqmm, compressive strength of 35MPa at 7 day and 45MPa at 28 days, at the outer or inner RCC , Versatile having specific gravity of 1.02 cement sand can be used for finishing purpose of BSSF complete all as specified and directed by Engr-in-charge.
M & L providing and filling three components compound (A) graded filler (B) E-Resins (C) thixotropic agents with adjustable consistaqncy by varying the filler component . having the density of 1.64 - 1.68gm/cc of Max treat EPG. after opening up in “V” groove manner covering the area of 300mm from central line of crack with the depth of 10 mm complete all as specified and directed by Engr-in-charge.
M & L for applying 3 coats of cement based waterproofing coating with high negative hydrostatic, good adhesion to substrate and enhanced durabiltiy on concrete or masonry walls. The waterproofing coating of elasto plast 10 should have adhesion to substrate of 1.3 Mpa after 28 days, elasticity modulus of 14000 - 16000 N/mm2 after 28 days and average water/ powder demand of 0.24 to 0.26 for fluid consistency complete all as specified and directed by Engineer in Charge.
M & L for providing and laying 2 coats of acrylic elastomeric waterproofing coating. The coating to be applied on wall shall be liquid applied highly durable waterproof coating system for wall, based on high quality acrylic emulsion, functional filler, sunlight stable pigment and quality fungicides. It shall have properties that provide features like crack bridging ability, breathability, flexibility & exterior durability and resists micro-organism growth.It shall cover hairline cracks up to 0.5 mm effectively. It shall have excellent crack bridging ability and shall bridge cracks up to 2 mm width. The elongation at break is approx. 220 %. The tensile strength is 0.7 Mpa. It has a hardness shore ‘A’ scale of 80, with an adhesion strength of 3.4 Mpa. The coating is UV resistant, algae and fungus resistant, and has a water vapor permeability of 40 gm/m²/day and a crack bridging ability of 1-2 mm. The coating must be applied with temperature above 5°C and below 45°C. The coating shall be applied in two coats of by roller or brush application at the interval of 4-6 hours.Allow applied coating to dry or cure for 7 days. complete all as specified and directed by Engr-in-charge
M & L for High Strength Corrosion Resistant Deformed TMT Bars of 8mm dia, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
SCHEDULE 'A' PART-II [E/M Works]: M & L for Point wiring with PVC insulated unsheathed multistranded copper conductor cable FRLS grade of size 1.5 Sqmm (nominal area) 1100V grade drawn through and including concealed PVC conduit of size 20mm dia medium grade including accessories fixed on wall/floor/roof, etc including provision of flush type metal GI boxes with modular cover plates, provision of PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 1.5 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for One light / fan point / Bell point controlled by one, one way switch including taking down old point wiring with fixtures and fittings complete all as specified and directed. [Note: Quoted rate is deemed to be inclusive for cutting through wall, chasing, pinning in making good to the disturbed surfaces whrever required]
All as per item No. 64 above but suitable for one 5/6 Amps socket outlet point controlled by one switch on the same board
All as per item No. 64 above but suitable for one 5/6 Amps socket outlet point controlled by one switch on independent board
All as per item No. 64 above but point wiring with PVC insulated, unsheathed multistranded copper conductor FRLS grade of size 2.5 Sqmm (nominal area) suitable for one 15 Amps power point on independent board complete all as specified and directed.
S & F modular switch single pole, 1 way, 6 Amps, 1 module
S & F modular switch single pole, 1 way, 16 Amps, 1 module
S & F modular socket outlet, 6 Amps, 2/3 pin combined 2 module
S & F modular socket outlet, 6/16 Amps, 2/3 pin combined 2 module
S & F modular electronic fan regulator, socket type, 2 module complete all as specified and directed.
S & F ceiling rose, 3 terminals, PVC/ polycarbonate, isolated body complete all as specified and directed
Supply and fixing LED lights fitting 1x20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete including taking down old fittings of any type and making good disturbed surfaces to match with existing complete all as directed
S & F in repairs Building Security light LED type of minimum 35 Watt, 230 V, AC new generation energy saving & environmental friendly long life made up of Pressure die cast aluminium housing IP 66 protection with all accessories internally prewired and including connecting up with twin core twisted copper conductor cable of suitable size including bracket made of 32mm dia GI light grade pipe of 1.5m long bent to shape fixed with suitable MS clamps, bolts, nuts and washers duly painted including taking down old fittings with brackets complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs Vertical TPN DB double door for provision for four pole MCCB upto 63 A incommer 4 way 12 outgoing with IP 43 protection complete all as specified and as directed. [Make:-Hager Cat Part No. VYV04DL-P double door or its equivalent.]
S & F in repairs MCCB 415 V , 16 KA, 4 Pole, 63 Amps capacity complete all as specified and as directed. [Make :-Hager Cat Part No. HDA064Z or its equivalent.]
S & F in repairs MCB DB, SPN, 12 Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs flush mounted with wall complete all as specified and as directed.
S & F in repairs MCB, SPN, 6-32 Amps, 240 Volts, 10 KA, C series
S & F in repairs MCB, SP 6 to 32 Amps, 240 Volts, 10 KA, C series
S & F in repairs MCB DB, TPN, 4 Way, 415 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs flush mounted with wall complete all as specified and as directed.
S & F in repairs MCB, 4 Pole, 40 Amps, 415 Volts, 10 KA, C series
M & L for sub main wiring with 2 runs of single core 1100 volts grade, PVC insulated, unsheathed, FRLS copper conductor cable of size 2.5 Sqmm, drawn through and including 20mm dia concealed PVC conduit and conduit accessories including provision of 1 run of 2.5 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor including taking down old sub main wiring complete all as specified and directed. [NOTE: 3 runs of 2.5 Sqmm copper wire and 1 run of PVC conduit shall be measured as one unit length.]
M & L for sub main wiring with 2 runs of single core 1100 volts grade, PVC insulated, unsheathed, FRLS copper conductor cable of size 4.0 Sqmm, drawn through and including 20mm dia concealed PVC conduit and conduit accessories including provision of 1 run of 4.0 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor including taking down old sub main wiring complete all as specified and directed. [NOTE: 3 runs of 4.0 Sqmm copper wire and 1 run of PVC conduit shall be measured as one unit length.]
M & L for sub main wiring with 4 runs of single core 1100 volts grade, PVC insulated, unsheathed, FRLS copper conductor cable of size 6.0 Sqmm, drawn through and including 32mm dia concealed PVC conduit and conduit accessories including provision of 1 run of 6.0 Sqmm PVC insulated, unsheathed, FRLS copper conductor cable as earth continuity conductor including taking down old sub main wiring complete all as specified and directed. [NOTE: 5 runs of 6.0 Sqmm copper wire and 1 run of PVC conduit shall be measured as one unit length.]
Taking down existing Ceiling Fan of any description and capacity from its original position and refixing the same in position after repairs to buildings after carrying out necessary servicing, cleaning, greasing including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of suitable size, replacement of minor spares such as capacitor, canopy, cotter pin, rubber bushes, nuts & bolts, washers and spray painting with one coat of synthetic enamel paint of approved colour duly filling the cavities with filler complete all as specified and as directed.
Taking down existing Wall mounted Fan of any description and capacity from its original position and refixing the same in position after repairs to buildings after carrying out necessary servicing, cleaning, greasing including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of suitable size, replacement of minor spares such as capacitor, canopy, cotter pin, rubber bushes, nuts & bolts, washers and spray painting with one coat of synthetic enamel paint of approved colour duly filling the cavities with filler complete all as specified and as directed.
Taking down existing Exhaust Fan of any description and capacity from its original position and refixing the same in position after repairs to buildings after carrying out necessary servicing, cleaning, greasing including connecting up with three core PVC insulated, sheathed flexible copper conductor cable of suitable size, replacement of minor spares and spray painting with one coat of synthetic enamel paint of approved colour duly filling the cavities with filler complete all as specified and as directed.
Supply and Laying LT XLPE insulated, PVC sheathed, bedded, galvanised steel strip or wire armoured, heavy duty, electric power cables of size 3.5 core 25 Sqmm, 1100 volts grade, with aluminium conductor laid in trenches / passing through pipe / duct / road crossing / fixed on poles / walls and connecting up with suitable glands, lugs, nuts and bolts and testing on completion including taking out old unserviceable cable complete all as specified and directed by the Engineer-in-Charge.
Supply and Laying LT XLPE insulated, PVC sheathed, bedded, galvanised steel strip or wire armoured, heavy duty, electric power cables of size 4 core 16 Sqmm, 1100 volts grade, with aluminium conductor laid in trenches / passing through pipe / duct / road crossing / fixed on poles / walls and connecting up with suitable glands, lugs, nuts and bolts and testing on completion including taking out old unserviceable cable complete all as specified and directed by the Engineer-in-Charge.
M & L for Point wiring with ZHFR insulated unsheathed multistranded copper conductor cable single core of size 1.5 Sqmm (nominal area) 1100V grade drawn through and including concealed stove enamelled steel conduit of size 20mm dia medium grade including accessories fixed on wall/floor/roof, etc including provision of flush type metal GI boxes with modular cover plates, provision of ZHFR insulated, unsheathed multistranded copper conductor of size 1.5 Sqmm as earth continuity conductor and connecting to common earth dolly suitable for One light / fan point / Bell point controlled by one, one way switch including taking down old flame proof point wiring with fixtures and fittings complete all as specified and directed. [Note: Quoted rate is deemed to be inclusive for cutting through wall, chasing, pinning in making good to the disturbed surfaces whrever required]
All as per item No. 91 above but point wiring with ZHFR insulated, unsheathed multistranded copper conductor of size 2.5 Sqmm (nominal area) suitable for flame proof 5/15 A switch points complete all as specified and directed.
S & F Switch flame proof rotary type with termination box in LM6, 6A, single pole 250V complete all as specified and directed
S & F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed
S & F in repairs 20W, LED flame proof tube light fittings with IP65 protection complete all as specified and directed
S & F in repairs 40 Watt CMRI certified LED Flameproof Bulkhead / Wellglass luminairie recommended for Gas / Vapor Group of IIA & IIB and Zone 1 & 2 with Die cast aluminium housing with heat resistant toughened glass, IP65 protection with driver holder connector, etc complete with all fixing accessories and connecting up complete all as directed
S & F in repairs 1x200W vertical suspended highbay LED light pressure die cast aluminium housing well glass luminairies with high power LED as light source including connecting and proper fixing with suitable clamps, nut, screws, etc complete all as directed
S & F concealed fire retardant flexible metallic conduit 25mm dia exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. including taking out old conduit complete all as directed
S & F in repairs Aluminium strip 25 x 3.15mm for lightning conductor with saddles and fixing screws etc. for roof conductors and down conductors laid in trench/ floor including necessary clamps, nuts, bolts, and hylem sheet block complete all as directed
S & F in repairs GI strip of size 32x6mm for lightning conductor with saddles and fixing screws etc. for roof conductors and down conductors laid in trench/ floor including necessary clamps, nuts, bolts, and hylem sheet block complete all as directed
Earthing complete with Galvanized steel earth plate electrode of size 600x600x6mm thick buried directly in ground with earth pit not less than 2.25m deep below the normal ground level with top edge of plate not less than 1.5m below normal GL connected with GI earth strip 32x6mm as earth lead by means of bolts, nuts, check nuts and washers of Galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including taking out old perished earth pits complete all as directed. [Note: The unit rate shall be deemed to include for excavation & earth work in any type of soil, PCC (1:3:6) type C1 chamber, MS angle iron frame 40x40x6mm, RCC 1:2:4 type B-1 cover 40mm thick with 8mm dia steel reinforcement bars at 150mm c/c both ways, MS handle 12mm dia, CI funnel and wire mesh, GI watering pipe 20mm dia medium grade for watering, GI protection pipe light grade 40mm dia, earthing lead upto 7.5m including providing charcoal or coke and common salt in alternate layers of 15cm compacted thickness all around the electrode complete all as specified in preambles of SSR Part-II and as shown in plate No. 3 of SSR Part-I.]
S & F in repairs Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed.
S & F Test terminal box of size 175x150x100mm made out of 2mm thick hot dip galvanised sheet drilled and screwed including 4 Nos 25mm long hexagonal head screwed with test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screw complete all as directed
M B CONSTRUCTIONS (BID ID -3487469)
JAYAM BUILD CONSTRUCTIONS (BID ID -3498988)
sai ganesh enterprises (BID ID -3493380)
RAGHU RAMA PANDA (BID ID -3498907)
stage.html
html • 0.05 MB
technical_826965.pdf
techsummary_826965.pdf
finance_826965.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.58 MB
82619tender.pdf
Tender Documents • 1.41 MB
BOQ_826965.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .