Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.0 LAccepted-AOC 204B SENTHAMANGALAM GOTHANDARAMPURAM VILLAGE PERUMANADU POST VAYALOGAM VIA PUDUKKOTTAI DIST TN | PUDUKKOTTAI | TAMIL NADU | 622104 | L1 | Accepted-AOC Admitted | |
| 2 | L2₹41.9 L+₹5.5 L (15.2%)Rejected-Finance NO 3 132 MINIKKIYUR KOVILPATTI PO PIRAMPATTI NORTH MANAPPARAI TK TIRUCHIRAPPALLI DIST PIN 621 305 | MANAPPARAI | TIRUCHIRAPPALLI | TAMIL NADU | 621305 | L2 | Rejected-Finance Being Not the Lowest Tenderer | |
| 3 | L3₹42.3 L+₹6.0 L (16.5%)Rejected-Finance C 150 ADG P CHENNAI | L3 | Rejected-Finance Being Not the Lowest Tenderer | |
| 4 | L4₹45.9 L+₹9.6 L (26.3%)Rejected-Finance | L4 | Rejected-Finance Being Not the Lowest Tenderer |
| Sl No | Description | Qty | Unit | M Govindarajan L1 | S.RAMACHANDRAN L3 | ACK ENGINEERING AND CONSTRUCTION L2 | Reliance Sales Agency L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of terracing tiles, single layer on roofs bedded in lime or cement mortar with tiles all as specified and directed. | 1,152 | SQM | 55 ₹63,360 Lowest | 120 ₹1,38,240 | 90 ₹1,03,680 | 80 ₹92,160 |
| 2.00 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed. | 46.08 | CUM | 1,550 ₹71,424 | 1,200 ₹55,296 Lowest | 1,850 ₹85,248 | 2,750 ₹1,26,720 |
| 3.00 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. and brushing neat cement slurry with 3.0Kg of cement per Sqm all as specified and directed. | 1,152 | SQM | 60 ₹69,120 | 45 ₹51,840 Lowest | 80 ₹92,160 | 80 ₹92,160 |
| 4.00 | Providing cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregate average thikness 40mm as in padding/ leveling concrete all as specified and directed. | 1,152 | SQM | 335 ₹3,85,920 Lowest | 420 ₹4,83,840 | 400 ₹4,60,800 | 350 ₹4,03,200 |
| 5.00 | Plain cement concrete type B0, 1:2:4 using 12.5mm graded stone aggregate inroof kerbs or mud stops, rounded or chamfered on edges in lintel upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets an an railing upto 60cm in height, coping, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified and directed. | 0.83 | CUM | 10,200 ₹8,466 Lowest | 12,000 ₹9,960 | 12,000 ₹9,960 | 14,000 ₹11,620 |
| 6.00 | Rendering 10mm thick in cement mortar 1:4 with WPC over roof finished fair and even complete all as specified and directed.
Note: Supply of WPC shall be measured and paid separately. | 1,152 | SQM | 250 ₹2,88,000 Lowest | 330 ₹3,80,160 | 350 ₹4,03,200 | 350 ₹4,03,200 |
| 7.00 | Supply only liquid water proofing compound all as specified and directed. | 170 | KG | 85 ₹14,450 Lowest | 120 ₹20,400 | 120 ₹20,400 | 290 ₹49,300 |
| 8.00 | APP modified prefabricated polymeric water proofing membrane 4mm thick and weighing not less than 4.5 kg/sqm reinforced with non-woven polyester matt black finished weighing not less than 100 gm/sqm having softning point less than 140 degree celcius longitudinal tensile strength not less than 300N/sqcm, side lap and end lap 10cm with torch application of membrane over compatible primer at 0.40 Ltr/sqm and aluminium paint applied at 0.10 kg/sqm finished on top complete all as specified and directed.
Note: The work shall be done by the authorised applicator as approved by the GE | 1,152 | SQM | 1,100 ₹12,67,200 Lowest | 1,110 ₹12,78,720 | 1,200 ₹13,82,400 | 1,400 ₹16,12,800 |
| 9.00 | Taking down eaves gutters and rainwater pipes (any size or pattern) including all fittings, heads, shoes, bends, swan-necks etc. (measured overall as fixed along the centre line over fittings and accessories) all as specified and as directed | 100 | RM | 55 ₹5,500 Lowest | 75 ₹7,500 | 75 ₹7,500 | 80 ₹8,000 |
| 10.00 | PVC (SWR) 110mm dia bore pipe single socketed in any length, with rubber ring joint fixed to walls with PVC clamps complete all as specified and directed. | 100 | RM | 520 ₹52,000 | 540 ₹54,000 | 560 ₹56,000 | 450 ₹45,000 Lowest |
Tender Value
₹35.9 L
EMD Value
₹71,700
Closing Date
27 Jan 2026, 6:00 pmClosed
GE WELLINGTON
Garrison Engineer Wellington Barrack Post Nilgiris Pin code-643231
SPECIAL REPAIRS TO PROOF RANGE PR 3 INSIDE PROOF RANGE OF DGQA UNDER GE WELLINGTON
2026_MES_747112_1
8190/E8
Open Tender
Civil Works
Item Rate
120 days
Trichy
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE WELLINGTON
₹71,700
Yes
9 Apr 2026
3 Jan 2026
29 Jan 2026
4 Jan 2026
27 Jan 2026
19 Jan 2026
Demolition of terracing tiles, single layer on roofs bedded in lime or cement mortar with tiles all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. and brushing neat cement slurry with 3.0Kg of cement per Sqm all as specified and directed.
Providing cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregate average thikness 40mm as in padding/ leveling concrete all as specified and directed.
Plain cement concrete type B0, 1:2:4 using 12.5mm graded stone aggregate inroof kerbs or mud stops, rounded or chamfered on edges in lintel upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets an an railing upto 60cm in height, coping, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified and directed.
Rendering 10mm thick in cement mortar 1:4 with WPC over roof finished fair and even complete all as specified and directed. Note: Supply of WPC shall be measured and paid separately.
Supply only liquid water proofing compound all as specified and directed.
APP modified prefabricated polymeric water proofing membrane 4mm thick and weighing not less than 4.5 kg/sqm reinforced with non-woven polyester matt black finished weighing not less than 100 gm/sqm having softning point less than 140 degree celcius longitudinal tensile strength not less than 300N/sqcm, side lap and end lap 10cm with torch application of membrane over compatible primer at 0.40 Ltr/sqm and aluminium paint applied at 0.10 kg/sqm finished on top complete all as specified and directed. Note: The work shall be done by the authorised applicator as approved by the GE
Taking down eaves gutters and rainwater pipes (any size or pattern) including all fittings, heads, shoes, bends, swan-necks etc. (measured overall as fixed along the centre line over fittings and accessories) all as specified and as directed
PVC (SWR) 110mm dia bore pipe single socketed in any length, with rubber ring joint fixed to walls with PVC clamps complete all as specified and directed.
PVC (SWR) bend of any radius 110 mm dia complete all as specified and as directed.
Bands, straps, supports or stays for rainwater, ventilating pipes including bolts, if requried hooks (stay), heavy for large gates, hook and pintle hinges, large hasp and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe 290 Gde E-165 all as specified and as directed.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc, complete all as specified and as directed.
Redering 15mm thick in cement mortar 1:6 on fair faces of stone masonry surfaces of walls, finished even and smooth without using extra cement complete all as specified and as directed.
Preparation of new plastered wall surfaces and applying two coats of Exterior Emulsion Paint (Anti Fungal) white or tinted over a coat of exterior primer all as per manufacturers instruction complete all as specified and as directed. Note: Rates shall be quoted inclusive of required scafolding for a height upto 10 meters buildings.
Complete removal of existing treatment on wall, chalk whiting and applying two coats of oil bound distemper on old plastered surface all as specified and directed.
Preparation of new plastered wall surfaces and applying two coats of oil bound distemper over a priming coat using chalk whiting, complete all as specified and directed.
Preparating old decorated ceiling surfaces (plastered or unplastered) including cornices and pillasters and applying one coat of white washing complete all as specified and directed.
Complete removal of existing treatment on stone/ brick wall surfaces and applying two coat of exterior emulsion paint (Anti Fungal) white or tinted over a coat of exterior primer as per manufacturer's instructions and all as specified and as directed. Note: Rates shall be quoted inclusive of required scafolding for a height upto 10 meters buildings.
Preparation of old painted wooden surfaces exceeding 10cm width or girth and applying one coat of synthetic enamel paint all as specified and directed.
Preparation of old painted steel surfaces exceeding 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Dismantling Asbestos cement (corrugated, semi corrugated, etc.) sheets in roof covering complete all as specified and directed.
Material and labour for 6mm thick asbestos cement, corrugated or semi-corrugated sheet in roofs, walls etc fixed with L-type or J-type or cranked hook bolts all as specified and directed.
Raking out joints to random rubble or polygonal rubble uncoursed and keyed pointing with cement mortar 1:3 to random or polygonal rubble, uncoursed or brought upto course all as specified and directed.
Hacking out old glass and supply and fix Plain Sheet glass, 3 mm thick ordinary quality and glazing with oil putty and beads in squares not exceeding 0.5 sq. m in each pane all as specified and directed.
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete of any type (Casing & capping, surface or concealed conduite, wooden batten etc) including fixture and fittings such as tube light fittings, switches, ceiling roses, pendants, fan regulators, sockets etc removing material from site and keeping in safe custody for taking as schedule of credit/ depositing to MES store yard and making good to the disturbed surfaces of walls, floors, roof etc all as specified and directed.
Taking down DBs/ main switches of any make carefuly and type including teakwood boad / MS enclosure/ MCBs etc all accessories complete and making good disturbed surface to match the existing surface all as specified and directed.
Taking down carefully service cable of any nos of wire and size with earth wire on wooden batten/ surface conduit casing / caping complete with its all accessories including making good disturbed surface to match the existing surface all as specified and directed.
Point wiring complete with and including 1.5 Sq.mm (nominal area) single core multi stranded FRLS copper conductor PVC insulated unsheathed cable 1100 volts grade conforming to IS 694 marked with valid CML No. drwan through in and including surface in PVC casing & Caping with all accessories such as bends, tees, junction boxes etc, anodised steel terminal boxes for mounting fittings like switches, sockets and fan requlators etc with 3mm thick laminated sheet covers fixed with brass screws and cup washer including one run of 1.5 Sqmm PVC insulated and unsheathed multi strand FRLS copper conductor as green colour earht wire and connected to common earth dolly for one light point controlled by one switch with 1.5Sqmm size complete all as specified and directed.
All as per item No 29 hereinbefore but One ceiling fan point controlled by one switch with cable 1.5 Sqmm size complete all as specified and directed.
All as per item No 29 hereinbefore but One exhaust fan point controlled by one switch with cable 1.5 Sqmm size complete all as specified and directed.
All as per item No 29 hereinbefore but One 3 pin 5 amps socket outlet on the same board with other switches with cable 1.5 Sqmm size, complete all as specified and directed.
All as per item No 29 hereinbefore but One 3 pin 5 amps socket outlet on the independent board with other switches with cable 1.5 Sqmm size, complete all as specified and directed.
All as per item No 29 hereinbefore but with 2.5 Sqmm size PVC insulated and unsheathed 1100 volts grade signle core stranded (multistrand) copper conductor cable for 3/6 pin socket outlet 15 amps on one independent board all as specified and directed.
Wiring for circuit / sub main wiring with two runs of single core PVC insulated unsheathed cable 6.0 Sqmm (nominal area) 1100 volts grade multistranded FRLS copper conductor with one run of 6.0 Sqmm PVC insulated unsheathed multistranded single core copper canductor 1100 V grade and connecting to common earth drawn through in and including PVC casing & caping accessories etc. all as specified and directed. Note: Two runs of 6 sqmm as phase and netural wire, one run of 6.0 Sqmm wire of green colour as earth cable and one run of casing & caping shall be measured and paid as one length. (b) Proper colour coding of wires i.e R/Y/B colour wire for Phase, Black colour wire for neutral and green colour wire for earth wire be adhered strictley while executing at site.
Switch piano, flush type single pole, one way 6 Amp ISI marked all as specified and directed.
switch socket combination 2 in 1, 6 Amps flush type ISI marked complete all as specified and directed
Switch socket combination 2 in 1, 3 pin 6 and 16Amps flush type universal all as specified and directed
Eectronic fan regulator step type, flush type suitable on the existing phenolic laminated sheet etc as required all as specified and directed.
Ceiling rose, 3 terminals PVC / polycarbonate, isolated body all as specified and directed.
LED light fitting 1 x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specifie and directed. Make: Luker Cat Part No. Luker: LT520P or equivalent in Havells/Bajaj/Crompton
Supply and fix in replacement LED Buliding security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Make: Luker Cat Part No. LSTE036S or equivalent in Havells/ Bajaj/ Crompton
LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and directed. Make:HALONIX- Cat Part No. HLFLD-ML17-100-CW-R01 or equivalent in HAVELLS/ CROMPTON.
Supply and fix in replacement VTPN MCCB DB, 12 way suitable for three phase 440 volts with 200 Amps rated bus bar, double door type with provision for MCCB as incomer suitable for mounting incoming and outgoing MCB's single/double pole including dismantling of old existing complete all as specified and directed.
MCCB 4 pole, 415 V, adjustable type, 160 Amps with breaking capacity 36 KA all as specified and directed.
MCB DB TPN 4 way 415 volts, double door type with minimum capacity of 200 Amps rated bus bar including necessary dummy plate and necessary civil works all as specified and directed.
MCB DB SPN 8 way 240 volts, double door type with minimum capacity of 200 Amps rated bus bar including necessary dummy plate and necessary civil works all as specified and directed.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 Amps to 32 Amps in the MCB DB complete with connection testing and commissioning all as specified and directed.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single poles and Neutral (SPN) and current carrying capacity 40 Amps to 63 Amps in the MCB DB complete with connection testing and commissioning all as specified and directed.
Supply and fixing 415V, 10KA 'C' curve miniature circuit breaker (MCB) of Tripple pole and Neutral (TPN) and current carrying capacity 40 Amps to 100 Amps in the DB complete with connection testing and commissioning all as specified and directed.
Disconnecting electrical wire from ceiling rose, taking down ceiling fan of any type/size and make, revoving substances from bearing, bush by using kerosene oil, carrying out fresh lubrication using grease and to make the ceiling fan noise free for smooth functioning including painting replacement of worn-out/ unserviceable spares as required, replacement of PVC insulated unsheathed stranded twisted copper conductor cable of size 1.5 Sqmm upto 1.0 Mtr long assembling the repaired ceiling Fan, testing and hanging at position, connection with point wiring & Testing complete all as directed. Note: Replacement of worn out defective/unserviceable spare parts, flexible wire etc/ rewinding of ceiling fan and painting shall be measured and paid separately under relevant item of the schedule)
All as per item No 51 hereinbefore but for exhaust fan of size 300mm sweep all as specified and directed.
Supply only rubber real with nuts, bolts and washers and split pin complete for hanging of ceiling fan of any size all as specified and directed.
Capacitor 2.5mfd oil based suitable for 440V, 50Hz AC supply all as specified and directed. Make: Universal/ Usha/ Havells/ Tibcon/ Asian etc.
Supply and fixing ball bearing of any size and type suitable for any type / make / size of ceiling fan all as specified or directed. Make TATA/ NBC/ SKF.
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in hard dense soil all as specified and directed.
Returning, filling in, including spreading, watering and well ramming in layers not exceeding 25 cm thick using soils all as specified and directed.
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point as in soils all as specified and directed.
Supply and laying burnt bricks sub class B of old size laid dry in trenches for cable protection all as specified and directed.
Supply and filling in and spreading of tibba sand or riddled sand for cushining and covering of the UG cables in trenches all as specified and as directed.
Material and labour for laying XLPE insulator armoured heavy duty electric cable with aluminium conductor 1100V grade cross section 70 Sqmm 4 core laied in ground / fixed in wall all as specified and as directed.
cutting the existing road/ hard standing made of concrete or premix carpet, WBM, soiling and moorum filling including excavating for laying the cable/ pipe width 0.3 Mtr and depth 0.4Mtr all as directed and making good the road / hard using all old material as required at site to match the existing surface all as specified and as directed.
GI tubing light grade 100mm nominal dia in trench/ road/ pole for cable protection complete all as specified and as directed.
Earthing complete with GI earth plate electrode of size 600mm x 600mm x6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level ) with top edge of the earth plate not less than 1.5m below noraml ground level connected to galvanised earth wire 4m by means of GI nuts, bolts check nuts and washers earth lead protected by 15mm dia GI pipe light grade and connected to main distribution board/ earthing test point all as shown in electrical plate No 3 of SSR part 1 and all as specified including testing omn completion, NoteThe unit rate also including for excavation, earth work in any type of strata, palin cement concrete 1:3:6 mix type C1 pit 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways GI funnel with GI watering pipe 20mm dia med gde, wire mesh, protection pipe 15mm dia GI pipe light grade for earth lead upto 7.50m long complete.
Supply and fix in repairs Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire all as specified and directed.
Schedule of Credit (Minus) Rs. 14301.00 NOTE: Bidder shall insert credit amount of Rs. 14301.00 as rate in Green field under Col-5.
stage.html
html • 0.05 MB
technical_836620.pdf
techsummary_836620.pdf
finance_836620.pdf
BOQ Comparative Chart
xlsx
finsummary_836620.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
Tender8190.pdf
Tender Documents • 1.04 MB
BOQ_836620.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .