Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹91.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹97.1 L+₹5.4 L (5.84%)Rejected-Finance | L2 | Rejected-Finance As per approval to TEC Report by CA | |
| 3 | L3₹98.8 L+₹7.1 L (7.70%)Rejected-Finance NOT AVAILABLE | NA | NA | 121004 | L3 | Rejected-Finance As per approval to TEC Report by CA | |
| 4 | L4₹99.8 L+₹8.1 L (8.81%)Rejected-Finance | L4 | Rejected-Finance As per approval to TEC Report by CA | |
| 5 | Rejected-Technical | - | Rejected-Technical As per Approval to TEC Report by competent authority |
Tender Value
Refer Docs
Closing Date
12 Jun 2021, 6:55 pmClosed
Dy. General Manager (PnC)
Dy. General Manager (PnC),Parbati HE Project, Stage-II, Parbati Complex, Nagwain, Distt. Mandi (H.P), Pin - 175 121
Restoration of Internal Illumination System damaged due to fire incident- Supply, Installation, Testing and Commissioning of Illumination System at Power House of Parbati HE Project (Stage-II) (PROC-1856)
2021_NHPC_629177_1
NH/PP-II/PROC/1856/2021
Open Tender
Electrical Works
Works
210 days
Power House of PHEP-II, Suind, Sainj, Kullu(H.P.)
As per Tender Document
8 documents required · 8 mandatory
₹1,180
NHPC Limited
Exempted
22 Sept 2021
7 May 2021
17 Jun 2021
7 May 2021
12 Jun 2021
7 May 2021
Supply of LED Luminaire / Fixture of 40 Watt as per technical specifications
Installation, Testing and Commissioning of LED Luminaire / Fixture of 40 Watt as per technical specifications and installation as per drawing.
Supply of 2' x 2' LED Recessed Fixture of 40 W as per technical specifications
Installation, Testing and Commissioning of 2' x 2' LED Recessed Fixture of 40 W as per technical specifications and installation as per drawing.
Supply of LED Medium-Bay Light 120 W as per technical specifications
Installation, Testing and Commissioning of LED Medium-Bay Light 120 W as per technical specifications and installation as per drawing.
Supply of LED Hi-Bay Light 200 W as per technical specifications
Installation, Testing and Commissioning of LED Hi-Bay Light 200 W as per technical specifications and installation as per drawing.
Supply of LED Light 12 Watt (Bulk Head) as per technical specifications
Installation, Testing and Commissioning of LED Light 12 Watt (Bulk Head) as per technical specifications and installation as per drawing.
Supply of LED Light 40 Watt Well Glass Fitting as per technical specifications
Installation, Testing and Commissioning of LED Light 40 Watt Well Glass Fitting as per technical specifications and installation as per drawing.
Supply of Exit Board LED Type with Minimum 2Hr Backup as per technical specifications
Installation, Testing and Commissioning of Exit Board LED Type with Minimum 2Hr Backup as per technical specifications and installation as per drawing.
Supply of LED Tube Light (T-8) Single Side Supply 18/20 Watt Rod 4 Feet, should be installed at Existing Tube Light Fitting (Equivalent to 36 W Tube Light Rod) as per technical specifications
Installation, Testing and Commissioning of LED Tube Light (T-8) Single Side Supply 18/20 Watt Rod 4 Feet, should be installed at Existing Tube Light Fitting (Equivalent to 36 W Tube Light Rod) as per drawing.
Supplying and fixing of G.I. modular boxes of size as 8 Module (120mm x 135mm x 60mm) along with modular base and cover plate for modular switches in recess as per drawings and as per directions of Engineer-In-Charge.
Supplying & fixing of 5/6 Amps one way Modular Switch (Equivalent to one module) in existing switch box/cover plate including connections etc as per directions of Engineer-In-Charge.
Supplying & fixing of 5/6 Amps Socket (Equivalent to two module) in existing switch box/cover plate including connections etc as per directions of Engineer-In-Charge.
Supplying & fixing modular blanking plate on the existing modular metal box as per directions of Engineer-In-Charge.
Supply of 5/15 A Receptacle as per technical specifications
Installation, Testing and Commissioning of 5/15 A Receptacle as per technical specifications and installation as per drawing.
Supply of 63 A Receptacle as per technical specifications
Installation, Testing and Commissioning of 63 A Receptacle as per technical specifications and installation as per drawing.
Supply of 32 A Receptacle as per technical specifications
Installation, Testing and Commissioning of 32 A Receptacle as per technical specifications and installation as per drawing.
Supply of 14 SWG G.I. Earth Wire as per technical specifications
Installation of 14 SWG G.I. Earth Wire in existing conduit (separate rate for installation of 25 mm conduits is taken) with earthing of conduits as well as earthing of fixtures, work is as per technical specifications and installation as per drawing.
Providing and laying and fixing of One No. aluminium conductor as Armoured cable 10 Sqmm, 2-core, PVC insulated and PVC sheathed, armoured / XLPE power cable, working voltage 1100 volts grade on surface as per drawings.
Providing and laying and fixing of One No. aluminium conductor as Armoured cable 16 Sqmm, 4-core, PVC insulated and PVC sheathed, armoured / XLPE power cable, working voltage 1100 volts grade on surface as per drawings.
Providing and laying and fixing of One No. aluminium conductor as Armoured cable 50 Sqmm, 3.5-core, PVC insulated and PVC sheathed, armoured//XLPE power cable, working voltage 1100 volts grade on surface as per drawings.
Providing and laying and fixing of One No. aluminium conductor as Armoured cable 70 Sqmm, 3.5-core, PVC insulated and PVC sheathed, armoured//XLPE power cable, working voltage 1100 volts grade on surface as per drawings.
Supply of One No. aluminium conductor as Armoured cable 120 Sqmm, single-core, PVC insulated and PVC sheathed, armoured / XLPE power cable, working voltage 1100 volts grade as per technical specifications
Laying and fixing of One No. aluminium conductor as Armoured cable 120 Sqmm, single-core, PVC insulated and PVC sheathed, armoured / XLPE power cable, working voltage 1100 volts grade on surface/in cable trays as per drawings.
Supplying and drawing HRFR LS copper cable 2 x 1.5 SQ MM (two runs of 1.5 Sqmm), 1- core PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface/recessed, Steel/PVC conduit as per drawings
Supplying and drawing HRFR LS copper cable 2 x 2.5 SQ MM (two runs of 2.5 Sqmm), 1- core PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface/recessed, Steel/PVC conduit as per drawings
Supplying and drawing HRFR LS copper cable 2 x 4.0 SQ MM (two runs of 4.0 Sqmm), 1- core PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface/recessed, Steel/PVC conduit as per drawings
Supply of 25 MM G.I. conduit with accessories as per technical specifications
Laying / fixing of 25 MM G.I. conduit with accessories with proper clamping as per standards on surface as per drawings.
Supply of 20 MM G.I. flexible conduit with accessories as per technical specifications
Laying / fixing of 20 MM G.I. flexible conduit with proper clamping with cable tie as per standards on surface as per drawings.
Providing Services for dismantle of damaged panels, cables, cleaning of existing illumination system panels, shifting of new panels and inludes installation, commissioning & testing as mentioned in scope of work mentioned in detail in Section-IIB, ''SCC' of tender document.
Mika Engineers
MNBN ENTERPRISES
Vishal Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .