Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹30.8 LAccepted-AOC | 1 | Accepted-AOC AWARDED BEING THE LOWEST TENDERER | |
| 2 | 2₹34.9 L+₹84,685 (2.49%)Rejected-Finance | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 3 | 3₹35.0 L+₹99,387 (2.92%)Rejected-Finance | 3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 4 | 4₹43.9 L+₹9.9 L (29.1%)Rejected-Finance | 4 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
4 May 2022, 6:00 pmClosed
GARRISON ENGINEER (NAVAL BASE) VISAKHAPATNAM
GARRISON ENGINEER (NAVAL BASE) GANDHIGRAM POST VISAKHAPATNAM 530005
SERVICING AND REPAIRS OF CEILING FANS, EXHAUST FANS, WALL MOUNTING FANS, PEDESTAL FANS AND OTHER ALLIED WORKS IN NAVAL PARK, AMZARI PARK, NEW AND OLD NAUSENABAUGH, KALYANI, SATAVAHANA, SAUW, VIRBAHU AND NAVAL DOCKYARD AREA UNDER GE (NB) VISAKHAPATNAM
2022_MES_505579_2
C/8002/22-23/E8 / Token 95 of 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
VISAKHAPATNAM
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER(NAVAL BASE)
₹90,000
Yes
28 May 2022
12 Apr 2022
6 May 2022
12 Apr 2022
4 May 2022
20 Apr 2022
Amount
Taking down and dismantling the ceiling fan 1200 / 1400 mm sweep of any capacity from existing position and removing its allied spare parts for cleaning, servicing, oiling and lubricating and replacement of unserviceable parts such as bearings, bushes, etc and refixing the same fan in its original position with all the parts i.e. down rod, canopies, fan blades, spilt pins, screws, nuts and spring washers etc complete including provn flexible copper conductor cable of 24 / 0.20mm of required length with necessary connector (for blade / body) as required after rewinding (if any) complete all as specified and directed. (Note : (i) Spare parts shall be measured and paid seperately as supply only and rewinding of fan shall be measured and paid seperatly under relevant item here-in-below. (ii) The cleaning, servicing, oiling and lubricating of fans has to be carried at site itself and to be completed within one hour unless re-winding is required. (iii) The cost of transportation from site of work to workshop and back for rewinding is deemed to be included in the unit quoted rate, (iv) Rewinding shall be carried out in contractor's workshop and fan shall be re-fixed at site within 10 days after taking down from site. Any delay after 10 days shall be penalised @ Rs. 100.00 per day for a maximum of 10 days).
All as per Serial item No. 01 above but exhaust fan of 225 to 600mm sweep of any capacity complete ditto.
All as per Serial item No. 01 above but air circulators/ pedestal fan/ wall mounting fan of any sweep and any capacity complete ditto.
M & L for rewinding of Ceiling fan of any sweep after dismantling with super enamelled bare insulated copper winding wires as per existing gauge and turn to achieve desired RPM including necessary insulating materials, insulating varnishing, cleaning, packing and reassembling and testing etc complete all as specified and as directed. ( Note: Also refer Note No. (iv) under Serial item No. 01 above)
All as per serial item No. 04 above but exhaust fan of 225 to 300mm sweep complete ditto
All as per serial item No. 04 above but exhaust fan of 450 to 600mm sweep complete ditto
All as per serial item No. 04 above but aircirculator/ pedestal fan/ wall mounted fan of any sweep complete ditto
Supply only ball bearing suitable for Ceiling fan of any sweep complete all as per the existing specifications and as directed (Make :TATA/ SKF / NBC)
Supply only ball bearing suitable for exhaust fan of any sweep complete all as per the existing specifications and as directed (Make : TATA/SKF / NBC)
Supply only ball bearing suitable for air circulator/ pedestal fan/ wall mounting fan of any sweep complete all as per the existing specifications and as directed (Make : TATA/SKF / NBC)
Supply only shackle and clamps including rubber bush, bolts, nuts, washer and split, canopies etc suitable for ceiling fan of any sweep complete all as per the existing specifications and as directed
Supply only bolts, nuts with frame and washers etc suitable for exhaust fan of any sweep complete all as per the existing specifications and as directed
Supply only fan capacitors of 2.5 Mfd complete all as specified and as directed. (Make : Havells/USHA/TIBCON)
Supply only fan capacitors of 4 Mfd complete all as specified and as directed. (Make : Havells/USHA/TIBCON)
Supply only brass bush suitable for ceiling fan of any sweep and capapcity complete all as per existing specification and as directed.
Supply only brass bush suitable for exhaust fan of any sweep and capacity complete all as per existing specification and as directed.
Supply only MS down rod of size 15 mm bore, 12" long including making holes etc for ceiling fan of any sweep and capacity complete all as per existing specification and as directed.
Supply only MS down rod of size 15 mm bore, 24" long including making holes etc for ceiling fan of any sweep and capacity complete all as per existing specification and as directed.
Supply only MS down rod of size 15 mm bore, 5 feet long including making holes etc for ceiling fan of any sweep and capacity complete all as per existing specification and as directed.
Supply only MS down rod of size 15 mm bore, 4 feet long including making holes etc for ceiling fan of any sweep and capacity complete all as per existing specification and as directed.
Supply only Metal blades set suitable for exhaust fan 225 to 300mm sweep any make complete all as per existing specification and as directed.
Supply only blades set suitable for ceiling fan 1200 / 1400 mm sweep any make complete all as per existing specification and as directed.
Supply only plastic blades set suitable for bathroom exhaust fan upto 300mm sweep of any make complete all as per existing specification and as directed. (Note for Item No . 08 to 23: The spares for fans repaired under Item No.1 to 3 above shall only be measured and paid under relevant items above.)
S & F in repairs steped type modular fan regulator ,100/120 W, 1/ 2 module complete all as specified and as directed.
S & F in repairs Stepped type electonic fan regulator flush type, 100W, 230 Volts complete all as specified and as directed.
S & F in repairs stationary louvers suitable for exhaust fan of 300mm sweep made out of powder coated aluminium anodised sheet of Min 1mm thick with non removable blades fixed permanantly at 45 degree angle for protection from rain including aluminium wire mesh of suitable size for bird control Complete all as per the existing specification and as directed. (Note: Louver has to fixed upto sixty metre height multistoried building. The unit quoted rate shall deemed to be inclusive of necessary scafolding and safety measure for fixing of louver upto sixty metre height. No extra claim on this account shall be entertained later on)
All as per Serial item No. 26 above but for exhaust fan of 450mm sweep complete ditto.
Taking down carefully existing ceiling fan of any size/sweep/make from it's existing position, sealing cable end, dismantling blades, cleaning all dust etc and painting with one coat of synthetic enamel (1st grade quality white) paint by spraying including filling cavities with filler and marking same MES No. with parmanent marker etc and re-hanging the ceiling fan and connecting up complete all as directed.
M & L for preparation of old painted surfaces of ceiling fan of any size/sweep/make, cleaning all dust etc and painting with one coat of synthetic enamel (1st grade quality white) paint by spraying including filling cavities with filler and marking same MES No. with parmanent marker etc complete all as directed. (Note: The ceiling fan taken down under Serial item No. 01 shall be painted and measured under this item.)
Taking down carefully existing exhaust fan of any size/sweep/make from it's existing position, sealing cable end, dismantling blades, cleaning all dust etc and painting with one coat of synthetic enamel (1st grade quality white) paint by spraying including filling cavities with filler and marking same MES No. with parmanent marker etc and re-fixing the exhaust fan and connecting up complete all as directed.
M & L for preparation of old painted surfaces of exhaust fan of any size/sweep/make, cleaning all dust etc and painting with one coat of synthetic enamel (1st grade quality white) paint by spraying including filling cavities with filler and marking same MES No. with parmanent marker etc complete all as directed. (Note: The exhaust fan taken down under Serial item No. 02 shall be painted and measured under this item.)
Taking down carefully existing air circulator/ pedestal fan/ wall mounting fan of any size/sweep/make from it's existing position, sealing cable end, dismantling blades, cleaning all dust etc and painting with one coat of synthetic enamel (1st grade quality white) paint by spraying including filling cavities with filler and marking same MES No. with parmanent marker etc and re-fixing the fan and connecting up complete all as directed.
M & L for preparation of old painted surfaces of air circulator/ pedestal fan/ wall mounting fan of any size/sweep/make, cleaning all dust etc and painting with one coat of synthetic enamel (1st grade quality white) paint by spraying including filling cavities with filler and marking same MES No. with parmanent marker etc complete all as directed. (Note: The air circulator/ pedestal fan/ wall mounting fan taken down under Serial item No. 03 shall be painted and measured under this item.)
S & F in repairs plastic blades set including frame suitable for bathroom exhaust fan upto 300mm sweep of any make complete all as per existing specification and as directed.
N Sydeswara Rao
NIKESH ENTERPRISES
VARADHI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .