Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
6 Jan 2022, 6:00 pmClosed
Lt Col Bhamre Kiran S
Military Engineer Service Garrison Engineer (AF) No.1 Air Force Station No.1 Jamnagar 361 003
REPAIR/MAINTENANCE OF BUILDINGS, AC SUBMAIN WIRING, AC BOX AND AND VARIOUS TYPE SUMMER APPLIANCES UNDER GE (AF) JAMNAGAR NO.1
2021_MES_495046_1
8144/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Jamnagar
Please refer Tender Documents
6 documents required · 6 mandatory
₹500
GE (AF) Jamnagar No. 1
₹82,000
Yes
25 Jan 2022
16 Dec 2021
7 Jan 2022
16 Dec 2021
6 Jan 2022
30 Dec 2021
Amount
M & L for annual servicing of Split Air conditioner cap 1.5/2.0 ton by disconnecting electric connection from its stabilizer or its electric board and remove the front cover or indoor AC unit and cleaning it with pressurized water and nylon brush , refixing the front cover of indoor unit . Remove the outer cover of out door unit and covered the condensing unit with ploythene/plastic cover so that water shall not be entered in the motor while cleaning the unit and filter with pressurized water then apply one coat of descaling solution and clean with wire mesh bursh/nylon brush to the condensing coil of out door unit and greasing of all moving parts. Cleaning........
.....of Cooling and condenser coil of indoor and outdoor unit shall be properly carried out without damaging other parts. Checking and making serviceable electrical connection of DBs, Stabilizer, wiring of ACs as per site condition and tightening all electrical connection Complete all as specified and directed . Note - Replacement of defective parts with new parts shall be measured and paid separately under respective items in the schedule.
Material and labour for Leak testing of cooling coils attached with indoor and outdoor unit of split air conditioner using CO2/Nitrogen gas, arrest of leakage with brazing of copper pipe and retest again for leakage complete all as specified and as directed.
M & L for charging of refrigerant R-410 gas to air conditioner or as per existing /manufacturer instructions suitable for split air conditioner cap 1.5 ton after flushing out the entire refrigerant , vacuum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas , as per manufacturer instructions, as mentioned above complete all as specified and as directed.
All as per item no.3 above but for 2.0 ton capacity complete as per manufacturer instructions and as directed by Engr-in-Charge.
M & L for charging of refrigerant R-22 gas to air conditioner or as per existing /manufacturer instructions suitable for split air conditioner cap 1.5 ton after flushing out the entire refrigerant , vacuum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas , as per manufacturer instructions, as mentioned above complete all as specified and as directed .
All as per item no.13 above but for 2.0 ton capacity complete as per manufacturer instructions and as directed by Engr-in-Charge.
Material and labour for maintenance of air conditioner 1.5/2.0 ton capacity , Split type unit with replacement of old/unsv spare parts mentioned as under or as per manufacturer instructions including testing on load complete all as specified and as directed by Engr-in-charge
S & F in repair over load protector suitable range and capacity.
S & F in repair Starting capacitor 80/100/120 mfd suitable for 240 volts 50 HZ AC supply
S & F in repair Running capacitor of 36/45/50/60 + 5/6 mfd suitable for 240 volts 50 HZ AC Supply
S & F in repair capacitor of 2.5 mfd suitable for suitable for blower fan motor of 1.5/2.0 ton AC
S & F in repair thermostat switch of suitable suitable for 1.5/2.0 ton AC
S & F in repair Compressor relay of suitable suitable for 1.5/2.0 ton AC
S & F in repair Control relay of suitable suitable for 1.5/2.0 ton AC
S & F in repairs brass service valve of size 5/8" suitable for Split AC
S & F in repairs brass service valve of size 3/8" suitable for Split AC
S & F in repairs copper tubing of size 3/8" suitable for split AC with nitrile self adhesive foam wrapped with PVC insulation all around the pipe line complete
S & F in repairs copper tubing of size 5/8" suitable for split AC with nitrile self adhesive foam wrapped with PVC insulation all around the pipe line complete
Supply and fix in repair flexible PVC pipe for condense water outlet as per existing all as directed & as site requirement.
S & F in repairs copper condenser coil suitable for split AC of cap 1.5/2.0 ton complete with necessary electrical connection
S & F in repairs evaporator copper cooling coil suitable for indoor unit split AC of cap 1.5/2.0 ton complete with necessary electrical connection
S & F in repairs Blower motor of 1/7 HP to 1/6 HP 230 volts 930 RPM, 20 Watt, 3 speed for indoor unit of split AC 1.5/2.0 TR of existing make complete Make :- Carrier / Voltas / LG / Samsung or as per existing make of AC at site.
S & F in repairs condenser fan motor 1/8 to 1/12 HP, 900/1400 RPM, 60 Watt suitable for 1.5/2 TR split AC outdoor unit, single phase, of existing make complete. Make:- LG/Bluestar/Voltas or as per existing make of AC at site.
S & F in repairs Condenser Fan motor for outdoor unit suitable for inverter type split AC 1.5/2.0 TR of existing make complete.
S & F in repairs Blower motor for indoor unit suitable for inverter type split AC 1.5/2.0 TR of existing make complete.
S & F in repairs Blade set of fan motor of out door unit, made out of Aluminium sheet Suitable for shaft bore dia 1/2" and fan dia 16"/ 18" in existing air conditioner split type .
S & F in repairs Blade set of fan motor of out door unit, made out of PVC Suitable for shaft bore dia 1/2" and fan dia 16"/ 18" in existing air conditioner split type
S & F in repairs Pre-air filter made up of PVC for indoor unit of split AC suitable for any make and description complete
S & F in repairs PVC fan blower assembly for 1.5 /2TR split AC's any make .
S & F in repairs Printed circuit board(PCB) with suitable for Split AC 1.5/2.0 TR of any capacity, model and make as per existing complete with necessary electrical connection.
S & F in repairs Printed circuit board(PCB) with hand set of indoor, outdoor and display unit suitable for Inverter type Split AC 1.5/2.0 TR of any capacity, model and make as per existing complete with necessary electrical connection.
S & F in repairs Swing motor of suitable for indoor unit of split AC suitable for any make and description complete
M & L for repairs to internal remote assembly cordless type suitable for split air conditioner with replacement of PCB, LED indicator and other micro components complete all a specified and directed by Engr-in Charge
M & L for replacement of defective cut open compressor/Uncut compressor suitable for air conditioner with new compressor filled with capila D and charging of refrigerant gas up to required capacity after flushing the complete refrigerant system including repair to leakage if any in refrigerant piping and replacement of filter complete for split type AC's of the following capacity complete all as specified and directed by Engr-in-charge.
1.5 ton capacity
2.0 ton capacity
S & F in repair air conditioner outdoor unit single phase as per existing brand complete with all connection and taking out old unsv for the following cap of air conditioner. Make : Samsung/Voltas/Carrier/LG/O General
1.5 ton capacity
2.0 ton capacity
Taking down / Dismantling carefully the indoor and outdoor unit of Split AC of capacity 1.5 TR / 2.0 TR with outdoor stand, plate for indoor unit and connected wiring, Transportation of complete set from old location to new location (with AF station Jamnagar), refixing of same AC at new location complete all as directed by Engr-in-Charge & detail as under:- (a) Fixing of indoor unit wall mounting type (to be installed inside the room) complete with, draining out arrangement for condensed water, fixing of inter connection pipe, all as directed. Fixing of cooling unit on wall shall be as per standard recommendation practice of manufacturers.
(b) Erection of condenser, compressor unit on outside of the building, fixed over old clamp / bracket, all as per standard practice of manufacturer.
(c) All civil work such as making hole in the wall for passing of pipe etc, to be done, as directed by Engr-in-Charge including making good disturbed surface. (d) concealing of refrigerant pipe with PVC flexible pipe. (e) Extension of pipe due to site condition if required shall be measured and paid separately under respective items taken before.
Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including heavy duty PVC rigid conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete. Note: 2 Runs of main cable and one run earth wire with conduit will be measured as one RM for payment.
Supply and fix MCB’s single pole 6-32 Amps, 230 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
Supply and fix MCB’s triple pole, 63 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
Supply and fix in repair metal clad single pole and earth enclosure with two pin and earth plugs and socket complete with one single pole MCB 20 Amps, 230 V, C type.
Comprehensive / Preventive maintenance of Industrial type Air conditioning of capacity 2.0 TR (Make: Emerson) with connected indoor and outdoor units, maintenance shall be carried out as per manufacturer standard check list and detailed as under all as directed by Engineer-in-Charge. (a) Cleaning the evaporator coil of indoor unit with pressurized water then apply one coat of descaling solution and clean with nylon brush and then testing/ checking of evaporator coil for leakage and rectification of leakage by brazing including.
(b) Cleaning of condensing coil of outdoor unit with pressurised water and then testing/ checking of Cooling coil for leakage and rectification of leakage by brazing including. (c) Testing / Checking and Cleaning of Air filter. (d) Testing / Checking of compressor for its proper functioning and rectification of minor defect if any.
(e) Testing / Checking & servicing of blower fan motor and rectification of minor defect if any. (f) Testing / Checking & servicing of condenser fan motor and rectification of minor defect if any. (g) Testing / Checking of control switch such as pressure cut outs, refrigerant flow switch, temperature sensor for proper functiong.
(h) Testing / Checking of refrigerant pipe for leakage and Rectification of leakage by brazing including cleaning of refrigerant pipe. (j) Testing / Checking of all electrical connection and control wiring tighting of electrical connection and rectification of minor defect if any complete.
Material & labour for charging of refrigerant R-407 gas to 2.0 TR capacity industrial type intelle split AC after flushing the complete system, vacuum testing up to 24 hours and the repairing the leaking tube / lines by brazing, including charging the unit with appropriate qty of gas as per manufacture's instruction complete all as directed by Engineer-In-Charge.
Dismantling blower fan motor (HP-0.33 , V-415, RPM-920) of industrial type intelle split AC 2 TR and supply and fixing new fan motor along with fan of existing make and size and refixing in position, connecting and testing on load including taking down old one and depositing in AGE(E/M) store yard all as specified and directed by Engineer-in-charge. Make :- SPARTAN ELECTRICAL PVT LTD or any other make as per recommendation of OEM and approved by the GE.
Dismantling Condenser fan motor(KW-0.18,RPM-920,FRAME-S90, IP-44) of industrial type intelle Split AC 2.0 TR capacity and supply and fixing new fan motor along with fan of existing make and size and refixing in position, connecting and testing on load including taking down old one and depositing in AGE(E/M) store yard all as specified and directed by Engineer-in-charge. Make :- SPARTAN ELECTRICAL PVT LTD or any other make as per recommendation of OEM and approved by the GE.
Material and labour for maintenance of Industrial type air conditioner 2.0 ton capacity, Split type unit with replacement of old/unsv spare parts mentioned as under or as per manufacturer instructions including testing on load complete all as specified and as directed by Engr-in-charge
Supply and fix in repair LP switch 60 NO 35 PSI , 6A 250V suitable for compressor of industrial type intelle split AC 2.0TR
Supply and fix in repair HP switch 400 NC 320 PSI suitable for compressor of industrial type intelle split AC 2.0TR capacity.
Supply and fix in repair expansion valve suitable for industrial type intelle split AC 2.0 TR capacity. Model- TUBE 06802073 03989 , Make- Danfoss or as per recommendation of OEM and approved by the GE.
Supply and fix in repair three pole contactor Model No. LC1D09 suitable for industrial type intelle split AC of 2.0 TR capacity. Make- Model No. LC1D09 of schneider or as of makes given in appendix B.
Supply and fix in repair over load protection relay suitable for industrial type intelle split AC of 2.0 TR capacity.
Supply and fix in repairs Supply Monitoring Device , Series-SM500,Type- PH, Neutral & Voltage Control suitable for control panel of industrial type intelle split AC.
Supply and fix in repair transformer suitable for control panel of industrial type intelle split AC of 2.0 TR Capacity Emerson .
Supply and fix in repair Display Controller unit of Industrial type Air conditioning of capacity 2.0 TR.
Supply and fix compressor Copeland scroll type , three phase , 415V, AC suitable for industrial type split Air Conditioner 2.0 TR Capacity working with R-407 Refrigerant gas including Flushing the complete refrigerant system and supply including recharging the refrigerant to the required capacity after leak detection and repair if any in refrigerant piping and replacing the filter complete all as specified and directed.
Supply and fix PVC insulated and FR PVC round sheathed , copper conductor flexible industrial cable , 1100 Volts of size 4sqmm x 4 core.
Supply and fix PVC insulated and FR PVC round sheathed , copper conductor flexible industrial cable , 1100 Volts of size 4sqmm x 3 core. Make- HAVELLS or equivalent make mentioned in appendix `B`
Comprehensive / Preventive maintenance including servicing of 12 HP capacity VRF based air conditioning system with connected indoor and outdoor units detail as under installed under GE(AF) Jamnagar for complete contract period detail as under all as specified and directed by Engr-in-charge.
Out door unit 12 HP capacity VRF unit of Make -Daikin, Model No - RXYQ12TRY69
Indoor unit :- Make Daikin a) Model no - FXAQ40PVE6 -09 nos b) Model no - FXAQ32PVE6 -01 no
Comprehensive / Preventive maintenance of VRF based air conditioning shall be carried out as per manufacturer standard check list and detailed as under all as directed by Engineer-in-Charge. (a) Testing / Checking of compressor for its proper functioning and rectification of minor defect if any. (b) Testing / Checking of control switch such as pressure cut outs, water flow switch, temperature sensor for proper functiong.
(c) Testing / Checking of PCBs of the Indoor unit & Outdoor unit for its proper functioning and rectification of minor defects if any. (e) Testing / Checking of Cooling coil for leakage and Rectification of leakage by brazing including cleaning of Cooling coil. (f) Testing / Checking & servicing of blower fan motor and rectification of minor defect if any. (g) Testing / Checking of all electrical connection and control wiring tighting of electrical connection and rectification of minor defect if any complete.
(h) Testing / Checking & servicing of condenser fan motor and rectification of minor defect if any. (j) Testing / Checking of condenser coil for leakage and Rectification of leakage by brezing including cleaning of condenser coil. (k) Testing / Checking of refrigerant pipe for leakage and Rectification of leakage by brezing including cleaning of refrigerant pipe. (l) Cleaning of entire indoor & outdoor unit for removing all dirt dust, grease etc
Note:- Comprehensive / Preventive maintenance including servicing of VRF unit shall be carried out two times during contract period, and shall be measured two times, Contractor shall also be responsible to rectify any defect during break down without any extra cost during contract period.
(i) All defective speared parts & compressor etc if found unserviceable will be measured & paid separately as supply & fix in repair under respective items of This BOQ,. (ii) Topping of refrigerant gas will be measured & paid separately.
(iii) The rates quoted by the tenderer shall be deemed to include for any minor repair, which are obviously and fairly, intended which may not have been included in these documents, but which are essential for the execution and entire completion of works. The decision of the Accepting Officer as to what constitutes Minor details of the construction’ shall be final and binding. (iv) Comprehensive / Preventive maintenance including servicing of VRF unit, & repairing the VRF unit during breakdown / emergency shall be carried out through authorised representative of OEM. Contractor shall submit necessary documentary proof in support of the same
All as per Item No 24 above 12 HP capacity VRF unit of Make Daikin, Model no - RXYQ12TRY69 with following indoor unit. Indoor unit :- Make Daikin a) Model no - FXAQ50PVE6 -02 nos b) Model no - FXAQ32PVE6 -03 no
All as per Item No 24 above but 12 HP capacity VRF unit of Make Daikin, Model no - RXYQ12TRY69 with following indoor unit. Indoor unit :- Make Daikin a) Model no - FXAQ40PVE6 -02 nos b) Model no - FXAQ63PVE6 -01 nos c) Model no - FXAQ32PVE6 -01 nos
All as per Item No 24 above but 10 HP capacity VRF unit of Make Daikin, Model No - RXYQ10TRY69 with following indoor unit. Indoor unit :- Make Daikin a) Model no - FXAQ50PVE6 -03 Nos b) Model no - FXAQ63PVE6 -01 No
All as per Item No 24 above but 10 HP capacity VRF unit of Make Daikin, Model no - RXYQ10TRY69 with following indoor unit. Indoor unit :- Make Daikin a) Model no - FXAQ40PVE6 -03 Nos b) Model no - FXAQ63PVE6 -02 Nos
All as per Item No 24 hereinbefore but 10 HP capacity VRF unit of Make Daikin, Model no - RXYQ10TRY69 with following indoor unit. Indoor unit :- Make Daikin a) Model no - FXAQ50PVE6 -02 nos b) Model no - FXAQ63PVE6 -03 nos
All as per Item No 24 hereinbefore but 10 HP capacity VRF unit of Make Daikin, Model no - RXYQ10TRY69 with following indoor unit. Indoor unit :- Make Daikin a) Model no - FXAQ63PVE6 -01 nos b) Model no - FXAQ50PVE6 -03 nos
All as per Item No 24 hereinbefore but 50 KW capacity VRV unit of Make Hitachi, Model no - RAS18FSXNK, Sr. No. 190G06595 with following indoor unit. Indoor unit :- Cap-4.1 TR, Make Hitachi a) Model no - RCL-5.0 FSKDNQ -04 nos
All as per Item No 24 hereinbefore but 50 KW capacity VRV unit of Make Hitachi, Model no - RAS18FSXNK, Sr. No. 190C49566 with following indoor unit. Indoor unit :- Cap-4.1 TR, Make Hitachi a) Model no - RCL-5.0 FSKDNQ -04 nos
Supply & Fixing in repair of inverter compressor suitable for 12 HP capacity VRF type AC unit (Make Daikin, Model no - RXYQ12TRY69) with base frame & electrical Phase reversal protection comprising following JOB:- (i) Charging of nitrogen Gas in unit & complete system at 300 psi pressure and checking of any dropping of pressure / leakage up to 72 Hrs after replacement of compressor & rectification of leakage if any.
(ii) Vaccumisation of complete system for minimum 2 days for dropping of vacuum pressure & rectification of leakage if any. (iii) Charging of complete system with R410 / R407 gas for maintaining the system pressure up to HP - 175 psi & LP - 65 psi.... (iv) Measure the inlet and outdoor temperature of package unit. (v) Testing & commissioning of compressor after completion.
Supply & Fixing in repair of inverter compressor suitable for 10 HP capacity VRF type AC unit (Make Daikin, Model no - RXYQ10TRY69) with base frame & electrical Phase reversal protection comprising following JOB:- (i) Charging of nitrogen Gas in unit & complete system at 300 psi pressure and checking of any dropping of pressure / leakage up to 72 Hrs after replacement of compressor & rectification of leakage if any. (ii) Vaccumisation of complete system for minimum 2 days for dropping of vacuum pressure & rectification of leakage if any.
(iii) Charging of complete system with R410 / R407 gas for maintaining the system pressure up to HP - 175 psi & LP - 65 psi.... (iv) Measure the inlet and outdoor temperature of package unit. (v) Testing & commissioning of compressor after completion.
Material and labour for maintenance of VRF air conditioner of 12/ 10 HP capacity, VRF type unit with replacement of old/unsv spare parts mentioned as under or as per manufacturer instructions including testing on load complete all as specified and as directed by Engr-in-charge Note:- Make of VRF unit is Blue star & Daikin therefore spear part provided in the work shall be of make Blue star / Daikin, contractor may use spare part of other make as approved by the OEM.
Supply & Fix in repair main control PCB of indoor Unit of VRF type AC unit complete all as specified and as directed.
Supply & Fix in repair power PCB for indoor unit of VRF AC complete all as specified and as directed.
Supply & Fix in repair pump to indoor unit of VRF AC unit complete all as specified and as directed.
Supply & Fix in repair hiwall controller to indoor unit of VRF AC complete all as specified and as directed.
Supply & Fix in repair HP/LP sensor to indoor unit of VRF AC complete all as specified and as directed.
Supply & Fix in repair sensors(Liquid, gas temp, room temp,supply temp) to indoor unit of VRF AC complete all as specified and as directed.
Supply & Fix in repair SMPS Board to indoor unit of VRF AC complete all as specified and as directed.
Supply & Fix in repair Over Voltage PCB to outdoor unit of VRF AC complete all as specified and as directed.
Supply & Fix in repair HP Switch to outdoor unit of VRF AC complete all as specified and as directed.
Supply & Fix in repair motor to outdoor unit of VRF AC of any capacity complete all as specified and as directed.
Supply & Fix in repair main power PCB of outdoor unit of VRF AC of any capacity complete all as specified and as directed.
Supply & Fix in repair master controller PCB of outdoor unit VRF AC of any capacity complete all as specified and as directed.
Supply & Fix in repair capacitor board of outdoor unit VRF AC of any capacity complete all as specified and as directed.
Supply & Fix in repair noise filter board of outdoor unit VRF AC of any capacity complete all as specified and as directed.
Supply & Fix in repair sensors (Liquid temp HeX 1&2, Gas temp HeX1&2) of outdoor unit VRF AC of any capacity complete all as specified and as directed.
Supply & Fix in repair Solenoid valve of outdoor unit of VRF AC of any capacity complete all as specified and as directed.
Supply & Fix in repair Fan Blade of outdoor unit of VRF AC of any capacity complete all as specified and as directed.
Supply and charging / topping up refrigerant gas R-410A to VRF type AC unit of any capacity all as directed by the Engineer in charge.
SURESH ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .