| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.5 LAccepted-AOC 02 RUDIA BIT MESRA ROAD NEORI VIKAS RANCHI JHARKHAND 835217 | RANCHI | JHARKHAND | 835217 | L1 | Accepted-AOC QUOTED AMOUNT IS LOWEST AND REASONABLE | |
| 2 | L2₹24.9 L+₹40,072.50 (1.63%)Rejected-Finance | L2 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT REASONABLE | |
| 3 | L3₹25.2 L+₹63,127 (2.57%)Rejected-Finance | L3 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT REASONABLE | |
| 4 | L4₹26.4 L+₹1.9 L (7.83%)Rejected-Finance | L4 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND NOT REASONABLE |
| Sl No | Description | Qty | Unit | AASHIRWAD ENTERPRISES L4 | M/S Akash Enterprises L3 | M/S SHAMBHU SHARAN SINGH L2 | THE SUVASH AND SONS L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/ gradient for laying cables/pipes,foundations,laying of cable, shafts, well, cesspits, manholes etc. complete all as specified and directed. | 206.5 | Cum | 265 ₹54,722.5 | 100 ₹20,650 Lowest | 210 ₹43,365 | 200 ₹41,300 |
| 2.00 | Returning, filling in including spreading, leveling, watering and well ramming in layers of not exceeding 25 cm thick after the cables & pipes etc. are laid, jointed & tested and foundations complete all as specified and directed by Engineer-in-Charge. | 185.9 | Cum | 75 ₹13,942.5 | 100 ₹18,590 | 50 ₹9,295 Lowest | 100 ₹18,590 |
| 3.00 | Removal of surplus excavated spoil not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified. | 20.65 | Cum | 65 ₹1,342.25 | 80 ₹1,652 | 50 ₹1,032.5 Lowest | 100 ₹2,065 |
| 4.00 | M & L for laying plain cement concrete (1:2:4),type B-2 (using 40 mm graded crushed stone aggregate) for supporting of CI/DI/GI pipes 0.60 RM below ground level and upto 5 RM above the ground level with smooth finishing without using extra cement, complete all as specified and as directed. | 2.6 | Cum | 5,500 ₹14,300 | 4,000 ₹10,400 | 2,500 ₹6,500 Lowest | 5,500 ₹14,300 |
| 5.00 | Taking up and down GI tubing including GI fittings complete from trenches/wall/ceiling /floor suitable for 15mm dia pipe, complete all as specified and as directed. | 490 | Rm | 15 ₹7,350 | 10 ₹4,900 | 10 ₹4,900 | 5 ₹2,450 Lowest |
| 6.00 | Taking up and down GI tubing including GI fittings complete from trenches/wall/ceiling /floor suitable for 20 mm dia pipe, complete all as specified and as directed. | 640 | Rm | 20 ₹12,800 | 10 ₹6,400 | 10 ₹6,400 | 5 ₹3,200 Lowest |
| 7.00 | Taking up and down GI tubing including GI fittings complete from trenches/wall/ceiling /floor suitable for 25 mm dia pipe, complete all as specified and as directed. | 580 | Rm | 25 ₹14,500 | 10 ₹5,800 | 10 ₹5,800 | 5 ₹2,900 Lowest |
| 8.00 | Taking up and down GI tubing including GI fittings complete from trenches/wall/ceiling /floor suitable for 40mm dia pipe, complete all as specified and as directed. | 490 | Rm | 30 ₹14,700 | 15 ₹7,350 | 10 ₹4,900 | 5 ₹2,450 Lowest |
| 9.00 | Taking up and down GI tubing including GI fittings complete from trenches/wall/ceiling /floor suitable for 50mm dia pipe, complete all as specified and as directed. | 530 | Rm | 35 ₹18,550 | 20 ₹10,600 | 20 ₹10,600 | 5 ₹2,650 Lowest |
| 10.00 | Taking up and down GI tubing including GI fittings complete from trenches/wall/ceiling /floor suitable for 150/100/80 mm dia pipe, complete all as specified and as directed. | 208 | Rm | 50 ₹10,400 | 25 ₹5,200 | 30 ₹6,240 | 5 ₹1,040 Lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
21 Mar 2026, 6:00 pmClosed
GE RAMGARH CANTT
RAMGARH CANTT
REPAIR MAINT OF IN ATTENDING THE DAY-TO-DAY COMPLAINTS, PETTY REPAIRS AND REPLACEMENTS OF GATE VALVE, BUTTERFLY VALVE, ARRESTING LEAKAGES IN WATER SUPPLY DISTRIBUTION SYSTEM AND CONNECTED ASSOCIATED WORKS OF OTM AND MD AREA OF SRC AT GE RAMGARH
2026_MES_754759_1
8300/3362/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
RAMGARH CANTT
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE RAMGARH CANTT
₹60,000
Yes
14 Jul 2026
28 Feb 2026
28 Mar 2026
28 Feb 2026
21 Mar 2026
14 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/ gradient for laying cables/pipes,foundations,laying of cable, shafts, well, cesspits, manholes etc. complete all as specified and directed. | 206.5 | Cum | 100 | ₹20,650 |
| 2 | Returning, filling in including spreading, leveling, watering and well ramming in layers of not exceeding 25 cm thick after the cables & pipes etc. are laid, jointed & tested and foundations complete all as specified and directed by Engineer-in-Charge. | 185.9 | Cum | 100 | ₹18,590 |
| 3 | Removal of surplus excavated spoil not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified. | 20.65 | Cum | 10 | ₹206.5 |
| 4 | M & L for laying plain cement concrete (1:2:4),type B-2 (using 40 mm graded crushed stone aggregate) for supporting of CI/DI/GI pipes 0.60 RM below ground level and upto 5 RM above the ground level with smooth finishing without using extra cement, complete all as specified and as directed. | 2.6 | Cum | 10 | ₹26 |
| 5 | Taking up and down GI tubing including GI fittings complete from trenches/wall/ceiling /floor suitable for 15mm dia pipe, complete all as specified and as directed. | 490 | Rm | 10 | ₹4,900 |
| 6 | Taking up and down GI tubing including GI fittings complete from trenches/wall/ceiling /floor suitable for 20 mm dia pipe, complete all as specified and as directed. | 640 | Rm | 10 | ₹6,400 |
| 7 | Taking up and down GI tubing including GI fittings complete from trenches/wall/ceiling /floor suitable for 25 mm dia pipe, complete all as specified and as directed. | 580 | Rm | 10 | ₹5,800 |
| 8 | Taking up and down GI tubing including GI fittings complete from trenches/wall/ceiling /floor suitable for 40mm dia pipe, complete all as specified and as directed. | 490 | Rm | 10 | ₹4,900 |
| 9 | Taking up and down GI tubing including GI fittings complete from trenches/wall/ceiling /floor suitable for 50mm dia pipe, complete all as specified and as directed. | 530 | Rm | 10 | ₹5,300 |
| 10 | Taking up and down GI tubing including GI fittings complete from trenches/wall/ceiling /floor suitable for 150/100/80 mm dia pipe, complete all as specified and as directed. | 208 | Rm | 10 | ₹2,080 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.58 MB
3362TENDER.pdf
Tender Documents • 2.34 MB
BOQ_845364.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .