Executive Engineer REW Samba
Office of the Executive Engineer REW Samba
Electrification of Panchayat Ghar at BADHERI PYT BADHERI BLOCK SAMBA District Samba
2021_RDPR_123653_7
e-NIT No.13REW Samba of 2021 Dated 01-05-2021
Open Tender
Electrical Works
Percentage
60 days
Samba
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
Executive Engineer REW Sambna
Exempted
4 Jun 2021
13 May 2021
22 May 2021
13 May 2021
21 May 2021
13 May 2021
60 days
Amount
Wiring for light point/ceiling fan point/fan point/exhaust fan point/call bell point with 1.5sqmm FRLS PVC insulated, copper conductor cable in surface/ recessed medium class PVC conduit with piano type switch,phenolic,laminated sheet,suitable size M.S. box and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc. as required. (Wire make ISI Havells/ Anchor/HPL/Shalimar/KEI/Polycab and conduit make- ISI Marked Anchor/High Power/Finloex/ National Gold/Shalimar/Ravindra. i. Group C
Wiring for light/power plug with 2*4 sq. Mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 4sq. Mm FRLS PVC insulated copper condutcor single core cable for loop earthing as required. (Refer CPWD DSR E&M 2018 item No. 1.12)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (Refer CPWD DSR E&M 2018 Item No. 1.14). 2 x 2.5 sq mm + 1 x 2.5 sq. mm earth wire (1.14.2)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1 x 1.5 sq. mm (1.17.1)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (Refer CPWD DSR E&M 2018 Item No. 2.3).
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (Refer CPWD DSR E&M 2018 Item No. 1.24).
5/6 A switch (1.24.1)
3 pin 5/6 A socket outlet (1.24.4)
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (Refer CPWD DSR E&M 2018 Item No. 1.25).
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. (Refer CPWD DSR E&M 2018 Item No. 1.26).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. (Refer CPWD DSR E&M 2018 Item No. 1.31).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. (Refer CPWD DSR E&M 2018 Item No. 1.32).
Supplying and fixing of following rating, 240/10 KA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. upto 32 amp (Refer CPWD DSR E&M 2018 Item No. 2.10).
Single Pole (2.10.1)( 6 to 32 Amp.)
MCB type Change over switch 40 amp
Earthing with copper earth plate 600mm x 600mm x 3mm including accessories and providing measonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr long etc with charcoal/coke and salt as required. (Refer CPWD DSR E&M 2018 Item No. 5.6).
Providing and fixing 4mm dia copper wire on surface or in recess for loop earthing along with existing surface/recessed conduit/sub main wiring/cable as required. (Refer CPWD DSR E&M 2018 Item No. 5.19).
Supplying and fixing of Angle/Baten Holder polycarbonate including making complete connnections etc as required. (Make as per annexure enclosed) (Refer CPWD DSR E&M 2018 Item No. 1.58).
Supplying and fixing of 9 watt LED Lamp.
Supplying and fixing of following rating, 240/10 KA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single Pole and Neutral 63 amp. (SPN)
Supplying of following electrical items suitable for operating on 240/230Volts AC, 50 Hz supply.
Ceiling Fan 1400 mm Sweep
1200 mm size 18-20 watt LED Batten Tube Light fitting of Aluminim Housing
Supplying and fixing of main service line 25 sqmm twin core aluminium cable unarmoured from the LT pole upto the MCB DB incluiding connections etc. as required. ISI marked
Supplying and fixing of 30 watt LED Street Light complete with GI pipe bracket duly embeded along the parapet /wall etc as required
GLOBAL ENGINEERS
MOHD. GULZAR CONTRACTOR
jai ambey trader
M/S GURPRAB BUILDERS
Surinder Kumar
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .