Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.6 LAccepted-AOC | L1 | Accepted-AOC Being L1. | |
| 2 | L2₹36.0 L+₹2.4 L (7.15%)Rejected-Finance 363 39KA HASSANGANJ BAWLI KUMAR COMPANY 363 39 KA HASAN GANJ BAWLI SAADAT GANJ LUCKNOW SAADATGANJ | L2 | Rejected-Finance Being not L1. | |
| 3 | L3₹37.6 L+₹4.0 L (12.0%)Rejected-Finance CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | L3 | Rejected-Finance Being not L1. | |
| 4 | L4₹38.0 L+₹4.4 L (13.0%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L4 | Rejected-Finance Being not L1. | |
| 5 | L5₹45.8 L+₹12.2 L (36.2%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L5 | Rejected-Finance Being not L1. |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
28 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) MC CHANDIGARH
GE (AF) MC CHANDIGARH
REPAIR AND MAINTENANCE OF AVR SYSTEM, POWER FACTORS PANELS, ATS AND OTHER CONNECTED WORKS AT BRD AF STATION UNDER GE (AF) MC CHANDIGARH
2022_MES_566526_1
GE (AF) MC /CHD-55/2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
CHANDIGARH
As per tender documents
8 documents required · 8 mandatory
₹500
GE (AF) MC Chandigarh
₹90,000
Yes
24 Feb 2023
1 Dec 2022
30 Dec 2022
1 Dec 2022
28 Dec 2022
15 Dec 2022
Amount
Maintenance, repair, servicing and over hauling for complete of 4 MVA HT AVR system for smooth running of auto & manual complete and worn out wiring of the same along with fixtures 11000 Volt AC supply operated system by locating faults and replacement of unserviceable parts and components complete all as specified and directed, as per following:- (a) Repair of faulty worn out control wiring with adequate and suitable size copper conductor wire, connected with proper copper lugs & terminals through protection pipe/casing. (b) Replacement of worn out indicating lamps, various type of copper lugs, thimbles terminals all as deemed necessary or directed including minor spare parts and components in order to make system serviceable and perfectly in working order (c) Material and labour for painting of 4 MVA HT AVR panel metallic body surface with one coat of superior quality synthetic enamel paint of approved colour Note : Supply & fixing, spare parts for replacement where required, will be included in quoted rates.
Dismantling and taking down after shut down electric supply complete 3 pole power contactor 800 Amps with universal coil for panel fitted and supply and fixing same size and same capacity 800 Amps power contactor with universal coil for AC/DC operation and electric connection with suitable size FRLS PVC insulated copper conductor cable and thimbles Complete all as specified and directed.
Supply and fixing Carbon roller assy suitable for power contactor 800Amp Complete all as specified and directed.
Supply and fixing Tag & Tail assy suitable for power contactor 800Amp Complete all as specified and directed.
Supply and fixing PCB Relay (1003) suitable for power contactor 800Amp Complete all as specified and directed.
Supply and fixing Flip flop suitable for power contactor 800Amp Complete all as specified and directed.
Supply and fixing Time delay relay suitable for power contactor 800Amp Complete all as specified and directed.
Supply and fixing Limit switch (B4C) suitable for power contactor 800Amp Complete all as specified and directed.
Supply and fixing Aux contactor 7 Nos + 4NC 44W, 230V AC Complete all as specified and directed.
Supply and fixing Aux contactor 4 Nos + 4NC 44W, 230V AC Complete all as specified and directed.
Supply and fixing Aux contactor 6 Nos + 2NC 62W, 110V AC Complete all as specified and directed.
Repair and servicing of transformer of 4 MVA HT AVR system of any make, any type and capacity ( step up /step down) installed at Take over point comprising with the flowing works:- (a) Taking out transformer oil upto required level and keeping in empty container with safe custody for re-use after servicing. (b) Opening of top cover of transformer and keeping a side and re-fixing the same after tightening of all HT terminal joints (both inside and outside of transformer) including supply and fixing all gasket of bushing of (8 mm thick rubberizes cork sheet) to make leak proof . (c) Checking of tap changing switch connections and tightening and soldering properly for smooth functioning. (d) Replacement of unserviceable bushing and terminals as ordered. (e) Filling up the transformer with existing taken out transformer oil and top up the same with new oil as ordered. (f) Cleaning of oil tank of transformer conservator, core, vent pipes, cooling pipe/fins by decarburizing and finally washing with transformer oil and drying complete. (g) Pouring of transformer oil in the transformer upto required level and connecting all cables and commissioning and testing with load complete Notes :- (i) Supply & fixing, spare parts for replacement where required, will be included in quoted rates. (ii) New transformer oil shall be measured and paid separately under respective items (iii) Any minor repair parts such as gaskets, nut, bolts, washers etc that are required to be replaced for satisfactory repair shall be provided by the contractor and rate for the same shall be deemed to be included with the unit rate (iv) In case dehydration of oil is necessary the same shall be also done at site and to be measured separately under appropriate items
Supply only HT porcelain bush set 11 KV for out door transformer of any size of capacity complete all as specified and directed.
Supply only HT terminals stud with nuts, washers made out of brass of suitable size for transformer complete all as specified and directed.
Filtration and Dehydration of HV/EHV grade transformer oil (dislodging of transformer minimum three cycles to achieve dielectric strength upto 60KV(rms) for EHV grade and upto 50KV rms for HV grade at 2 mm/2.5 gap complete all as specified and directed.
Supply and filling up transformer oil (Grade 'B') in Transformer, installed at various Sub Station, having Di-electric strength not less than 40 KV on 4mm over gap for a period of one minute complete all as specified and directed.
Excavation in trenches n exc 1.5 mtr wide and n exc 1.5 m in depth for laying of pipe/cable and getting out old unserviceable cable / pipe in any type of soil including cutting of grass and bushes complete all as specified and directed.
Returning filling in, including spreading leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed. .
Removal of excavated soil surplus to the requirement to a distance n.exc 50 mtr and depositing where directed at a level n exc 1.5 mtr above the starting point complete all as specified and directed.
Material and labour for sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Supply and laying precast concrete cable cover made of cement concrete grade M-30, class LV type 1, flat of size 250mmx150mmx40mm, complete all as specified and directed.
Laying only well burnt brick sub class 'B' old size brick laid dry in trenches with width equal to the length of the brick , complete all as specified and directed. Note:- Bricks are to be reused retrived during the cable taking out against respective items.
M&L for Boring hole under road/ pavement / hardstanding by trenchless technology using ultrasound technique & necessary machine with and including inserting HDPE pipe of 50mm dia, complete all as specified and directed.
Supply and laying in replacement of GI tubing 80mm bore light grade with all fitting laid in trenches, fixed to well etc complete all as specified and directed
Supply laying and testing XLPE insulated armoured heavy duty LT electric cable with aluminium conductor 1100 volts grade 3.5 core 400 sqmm cross sectional area including taking out existing unserviceable cable complete all as specified and directed . Note:- (i) Excavation and earth work shall be measured and paid for seperatly.
Supply laying and testing XLPE insulated armoured heavy duty LT electric cable with aluminium conductor 1100 volts grade 3.5 core 300 sqmm cross sectional area including taking out existing unserviceable cable complete all as specified and directed . Make:-Havells/Polycab/KEI Note:- (i) Excavation and earth work shall be measured and paid for seperatly.
Supply laying and testing XLPE insulated armoured heavy duty LT electric cable with aluminium conductor 1100 volts grade 3.5 core 35 sqmm cross sectional area including taking out existing unserviceable cable complete all as specified and directed . Make:-Havells/Polycab/KEI Note:- (i) Excavation and earth work shall be measured and paid for seperatly.
Supply laying and testing XLPE insulated armoured heavy duty LT electric cable with aluminium conductor 1100 volts grade 3.5 core 25 sqmm cross sectional area including taking out existing unserviceable cable complete all as specified and directed . Make:-Havells/Polycab/KEI Note:- (i) Excavation and earth work shall be measured and paid for seperatly.
Supply laying and testing XLPE insulated armoured heavy duty LT electric cable with aluminium conductor 1100 volts grade 4 core 16 sqmm cross sectional area including taking out existing unserviceable cable complete all as specified and directed . Make:-Havells/Polycab/KEI Note:- (i) Excavation and earth work shall be measured and paid for seperatly.
Supply and fixing in repair aluminium lugs for LT cable of size 300Sqmm, complete all as specified and directed.
Supply and fixing in repair aluminium lugs for LT cable of size 400Sqmm, complete all as specified and directed.
Maintenance, repair, servicing of main breaker of ACB 630 to 1000 amp and Disconnecting from mains electric supply and worn out wiring of the same along with fixtures of 440Volt AC supply operated system by locating faults and Repair of faulty worn out control wiring with adequate and suitable size copper conductor wire, connected with proper copper lugs & terminals through protection pipe/casing and worn out indicating lamps all as deemed necessary or directed including minor spare parts and components in order to make system serviceable and perfectly in working order complete all as specified & directed.
Supply and fixing in replacement of ACB, 415 volts , 4 pole , 50 Hz, with thermal Magnetic release (manual draw out type ) of capacity 630Amps as per existing size and make complete all as specified & directed.
Supply and fixing in replacement of ACB, 415 volts , 4 pole , 50 Hz, with thermal Magnetic release (manual draw out type ) of capacity 800Amps as per existing size and make complete all as specified & directed.
Disconnecting electric supply from main breaker, taking out ACB 630 amp and replacement of the following parts as per existing make:-
Microprocessor based OCR (IPR). Make Havells/Legrand/ Schneider
Spring charging motor. Make Havells/Legrand/ Schneider
Neutral CTs. Make Havells/Legrand/ Schneider
Under voltage trip device. Make Havells/Legrand/ Schneider
Adaptor type terminals. Make Havells/Legrand/ Schneider
Spring charge indication switch. Make Havells/Legrand/ Schneider
Position indication switch. Make Havells/Legrand/ Schneider
Main CTs. Make Havells/Legrand/ Schneider
Shunt trip/closing coil Make Havells/Legrand/ Schneider
Disconnecting electric supply from main breaker, taking out ACB 800 /1000 amp and replacement of the following as per existing make:-
Microprocessor based OCR (IPR). Make Havells/Legrand/ Schneider
Spring charging motor. Make Havells/Legrand/ Schneider
Neutral CTs. Make Havells/Legrand/ Schneider
Under voltage trip device. Make Havells/Legrand/ Schneider
Adaptor type terminals. Make Havells/Legrand/ Schneider
Spring charge indication switch. Make Havells/Legrand/ Schneider
Position indication switch. Make Havells/Legrand/ Schneider
Main CTs. Make Havells/Legrand/ Schneider
Shunt trip/closing coil Make Havells/Legrand/ Schneider
Maintenance, repair, servicing of automatic power factor controller panels from supply mains and worn out wiring of the same along with fixtures of 440Volt AC supply operated system by locating faults and replacement of unserviceable parts and components complete all as specified and directed, as per following:- (a) Repair of faulty worn out control wiring with adequate and suitable size copper conductor wire, connected with proper copper lugs & terminals through protection pipe/casing. (b) Replacement of worn out indicating lamps, various type of copper lugs, thimbles terminals all as deemed necessary or directed including minor spare parts and components in order to make system serviceable and perfectly in working order (c) Material and labour, painting of APFC panel metallic body surface with one coat of superior quality synthetic enamel paint of approved colour Note : Supply & fixing, spare parts for replacement where required, will be included in quoted rates.
S&F in replacement of FRLS PVC insulated copper conductor 1.5Sqmm single core cable with cable thimble/lugs made of copper in surface/recessed as required for LT panel repair with necessary fixtures as required at site complete all as specified & directed.
S&F in replacement of FRLS PVC insulated copper conductor 2.5Sqmm single core cable with cable thimble/lugs made of copper in surface/recessed as required for LT panel repair with necessary fixtures as required at site complete all as specified & directed.
Supply and fixing in replacement of intelligent automatic power factor controller relay 8 Steps with CT as per existing make and size complete all as specified and directed.
Supply and fixing in replacement of intelligent automatic power factor controller relay 12Steps with CT as per existing make and size complete all as specified and directed.
Supply and fixing in replacement of automatic power factor contactor 73 Amp 3 pole 415 volt, 37 KW,AC3 as per existing make and size complete all as specified and directed.
Supply and fixing automatic power factor contactor 50 Amp 3 pole 415 volt ,22 KW,AC3as per existing make and size complete all as specified and directed.
Supply and fixing in replacement of automatic power factor contactor 40 Amp 3 pole 415 Volt ,18.5 KW,AC3 as per existing make and size complete all as specified and directed.
Supply and fixing in replacement of automatic power factor contactor 32 Amp 3 pole 415 volt ,15 KW,AC3 as per existing make and size complete all as specified and directed.
Supply and fixing in replacement of Fixed capacitor 3 phase, 440 volts supply system, MD-XL type 30 KVAR as per existing make and size complete all as specified and directed.
Supply and fixing in replacement of Fixed capacitor 3 phase, 440 volts supply system, MD-XL type 25 KVAR as per existing make and size complete all as specified and directed.
Supply and fixing in replacement of Fixed capacitor 3 phase, 440 volts supply system, MD-XL type 20 KVAR as per existing make and size complete all as specified and directed.
Supply and fixing in replacement of Fixed capacitor 3 phase, 440 volts supply system, MD-XL type 15 KVAR as per existing make and size complete all as specified and directed.
Supply and fixing in replacement of Fixed capacitor 3 phase, 440 volts supply system, MD-XL type 12.5 KVAR as per existing make and size complete all as specified and directed.
Supply and fixing in replacement of Fixed capacitor 3 phase, 440 volts supply system, MD-XL type 10 KVAR as per existing make and size complete all as specified and directed.
Supply and fixing in replacement of Fixed capacitor 3 phase, 440 volts supply system, MD-XL type 7.50 KVAR as per existing make and size complete all as specified and directed.
Supply and fixing in replacement of Fixed capacitor 3 phase, 440 volts supply system, MD-XL type 5 KVAR as per existing make and size complete all as specified and directed.
Supply and fixing in replacement of Fixed capacitor 3 phase, 440 volts supply system, MD-XL type 2.5 KVAR as per existing make and size complete all as specified and directed.
Supply and fix in repair LED indicator lamps in RYB colour complete all as specified and directed.
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for straight through joint heat shrinkable complete with Jointing material (Epoxy Based) and accessories suitable for 3.5/ 4 core XLPE armored aluminium conductor cable of size 300Sqmm complete all as specified and directed. Make : Denson /M Seal
Supply and fix in repair cable jointing kit for 1.1 KV grade cable for straight through joint heat shrinkable complete with Jointing material (Epoxy Based) and accessories suitable for 3.5/ 4 core XLPE armored aluminium conductor cable of size 400Sqmm complete all as specified and directed. Make : Denson /M Seal
Supply and fix in repair Automatic Transfer Switch (ATS), 4pole, 415 Volts , with inbuilt time delay, with enclosures, of rating 200 Amp, confirming IEC-60947-1 and IEC-60947-6-1, complete all as specified and directed. Make: Havells/ L&T/ Indoasian/ ABB
Supply and fix in repair Automatic Transfer Switch (ATS), 4pole, 415 Volts , with inbuilt time delay, with enclosures, of rating 315 Amp, confirming IEC-60947-1 and IEC-60947-6-1, complete all as specified and directed. Make: Havells/ L&T/ Indoasian/ ABB
Supply and fix in repair Automatic Transfer Switch (ATS), 4pole, 415 Volts , with inbuilt time delay, with enclosures, of rating 400 Amp, confirming IEC-60947-1 and IEC-60947-6-1, complete all as specified and directed. Make: Havells/ L&T/ Indoasian/ ABB
Supply and fix in repairs decorative aesthetically designed inverted pyramid tripod type LED bollard light fitting of capacity 10W, voltage range 150-260 Volts, made up of aluminium casting with acrylic diffuser for soft illumination effect, the bollard trunk is of black powder coated with silver white finish for tripod stand, colour temp not exceeding 5200 K with driver and IP 65 rated complete including making connection complete all as specified and directed. Make :- Crompton (LBLSN-10-CDL) or equivalent in Havells/C&S
Supply and fix in repairs LED bollard light fitting of capacity 10W with robust design and efficient light distribution voltage range 150-260 Volts, made up of aluminium casting with acrylic diffuser for soft illumination effect, the bollard trunk is of black powder coated with silver white finish for tripod stand, colour temp not exceeding 5200 K with driver and IP 65 rated complete including making connection complete all as specified and directed. Make :- Crompton (LBLTW-10-CDL) or equivalent in Havells/C&S
Supply and fix in repair of sheet metal enclosure Single door for DB TPN 4 way, 415 volt with 200 Amps rated bus bar complete all as specified and directed.
S&F in repair MCB SPN 230V, AC, 10KA, 32Amps, C curve, 50Hz, complete all as specified and directed.
Supply and fixing in repair PVC insulated weather proof and sheathed flat twin core cable with aluminium conductor cable of size 6.00 sqmm drawn through conduit pipe/bracket or along the wall/pole or as in trenches including fixing on conduit/bracket and making connection to the fitting with over head line i.e connection to junction box fixed at bottom of pole complete all as specified and directed.
Supply and fixing in repair PVC insulated weather proof and sheathed flat twin core cable with aluminium conductor cable of size 10.00 sqmm drawn through conduit pipe/bracket or along the wall/pole or as in trenches including fixing on conduit/bracket and making connection to the fitting with over head line i.e connection to junction box fixed at bottom of pole complete all as specified and directed.
M&L for Pre-cast cement concrete block masonry with solid blocks in cement mortar 1:3:6 type C-1 using 20mm graded stone aggregate, block size not.exc 30cm in width suitable for LED bollard light fitting including grounding of nut bolt and fixing of DB ( SPN ) complete all as specified and directed.
Material and labour in replacement of earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick buried directly in ground vertically (depth of pit not less than 2.25m below normal ground level), with top edge of earth plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized iron strip of size 32 mmx6 mm thick (upto body of equipment) by means of nuts, bolts, check nuts & GI washers, connected to main switch board or main control board or test point, protected by galvanized iron pipe light grade 40mm dia bore, and watering pipe 20mm dia bore GI light grade with funnel & wire mesh including all necessary excavation & earth work, PCC chamber in PCC (1:2:4) type B-1 & RCC cover, all as shown in electrical plate No 3 of MES Schedule Part-I (2009), testing on completion, complete all as specified and directed. Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include GI strip and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3 Ohm, complete earthing will be redone without any extra cost to Govt.
Note:- Amount of credit of Rs. 141015.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in pdf form which will be deducted offline while acceptance of tender.
KUMAR AND COMPANY
Jai Maa Electrical Works
R D Bansal
Raman Electric Trading Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .