Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹30.2 LAccepted-AOC | L-1 | Accepted-AOC lowest | |
| 2 | L-2₹31.4 L+₹1.0 L (3.30%)Rejected-AOC | L-2 | Rejected-AOC other than lowest | |
| 3 | L-3₹32.5 L+₹2.1 L (7.04%)Rejected-AOC | L-3 | Rejected-AOC other than lowest | |
| 4 | L-4₹32.6 L+₹2.2 L (7.28%)Rejected-AOC AZAD COLONY B 90 FEET ROAD SOURA SRINAGAR J K 190011 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190011 | L-4 | Rejected-AOC other than lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
22 Feb 2022, 6:00 pmClosed
GE 969 EWS C/O 56 APO
GE 969 EWS C/O 56 APO
SPL REPAIR TO ELECTRIC AND WATER SUPPLY SYSTEM AT BLDG NO P-185 (JCOS LIVING) AT BARAMULLA, PROVN OF KERO CUM ELECTRIC WATER HEATER KHANDIYAR, FATEHGARH AND VENKARI COB OF RR , PROVOSION OF SOLAR PANEL WITH LED SECURITY LIGHT AT UPLONA , OTHER MISCE
2021_MES_488722_4
CANO 969/WS- /2021-22
Open Tender
Civil Works
Item Rate
180 days
Baramulla
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 969 EWS
₹60,000
Yes
17 Mar 2022
2 Feb 2022
24 Feb 2022
2 Feb 2022
22 Feb 2022
10 Feb 2022
Amount
Surface excavation n.exc 30 cm deepand averaging 15 cm deep and getting out in soft/loose soil complete all as specified and as directed .
Excavating in post holes (or similar holes) each n.exc 0.5 Cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not excedding 25 cm in any type of soil complete all as specified and as directed .
Excavation in trenches not exceeding 1.5 m wide & not exceeding 1.5 mtr in depth for laying of pipe in any type of soil complete all as specified and as directed .
Removing surplus excavated soil to a distance not exc 50 m and depositing where directed at a level not exc1.5 mtr above the starting point complete all as specified and as directed .
Returning, filling in, excavated soil including spreading, leveling, watering & well ramming in layers n. exc 25 cm thick complete all as specified and as directed .
M&L for PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate ) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L cement concrete in foundations filling and mass concrete type B-2, 1:2:4 (using 40mm graded crushed stone aggregate ) complete all as specified and as directed.
M&L for pre cast cement concrete (1:4:8) type D2 (using 40mm graded crushed stone aggregate ) for foundation filling of poles as mass concrete all as specified
M&L for cement concrete 1:2:4 type C1 (using 20mm graded crushed stone aggregate) cills, steps, coping, hold fast and the like including weathering, slightly rounded or chamfered angles and throating as directed with including necessary form work complete all as specified and as directed .
M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as specified
M&L for Sub class "B" bricks laid dry width wise across the line of cable in treanchs as cable protection complete all as specified.
M&L for preparation of new steel and iron surfaces of any discription applying two coat of synthetic enamel paint over a coat of red oxide paint complete all as specified and as directed .
M & L Preparing the newly flush pointed stone walls , newly plastered suurface of walls and applying two coats of cement base paint complete all as specified and as directed .
M&L Brick work with sub class 'B' bricks, straight or curved on plan n exc 6m mean radius built in CM 1:6, complete all as specified and as directed .
M&L rendering 15mm thick in CM (1:4) on other than fair faces of brick work or concrete surfaces, finished even and smooth with out using extra cement complete all as specified and as directed .
S&F mild steel framed work such as grills, frame work of water tanks FE 290 Gde E-165 complete all as specified and as directed.
M&L for Mild steel, plain, black sheet 1mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed in hearths, covering to door shutters; covering to door chowkats (frames), chullah hoods, water tanks, water troughs, ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed,holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc.,with plain 40 mm lap joints or welded/riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. all as specified and required
M&L for cross arms, bracings, supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, weldings, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat,one under coat and finishing coat of paint complete including dismantling existing rusted section complete all as specified and as directed .
M&L for clamps, bracing, supports and back plates made out of structural steel section including nuts, bolts and washers all as required at site for fixing GI tubing in truly vertical position including two coats of synthetic enamel paint over a coat of red oxide complete all as specified and as directed.
S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St-240 complete all as specified and as directed .
S&F pre-painted galvaturme aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering ,clading to wall, fixed with self tapping screws complete all as specified and as directed .
All as per item No 21 above but plain sheet as in ridge complete all as specified and as directed .
S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles as necessary gusset plates, riveting, etc confroming, to Fe. 290 Gde E-165 complete all as specified.
S&F 6mm thick Plates (Plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming with riveted, bolted or welded attachment confirming to Fe-290 (Gde E-165) etc complete al as specified.
Preparation of new or previously untreated steel surfaces of any description, over 10cm in width or girth, not otherwise described and apply two coat of synthetic enamel paint over a coat of red oxide, completed all as specified.
S&F Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed 15 mmfor iron pipe or for brass ferrule and fixed. complete all as specified and as directed .
S&F Gun-metal, globe or gate valves 20 mm, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed .
S&F Gun-metal, globe or gate valves 25 mm, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed .
S&F GI Pipe medium grade 25mm complete all as specified and as directed .
M&L for lagging on 20/25mm internal dia pipe all round with 25mm thick bounded mineral wool pre-formed "SNAP ON" pipe section of density of 144Kg/Cum confirm to IS 9842 including providing with chicken mesh wire netting 25 gauge 20mm mesh etc complete all as specified and as directed .
Supply & Fixing GI tubing, 20 mm medium grade, ISI marked complete with all fittings, laid in trenches or laid under floors, fixed on walls with and providing clamps etc complete all as specified and as directed .
M&L steel tube medium grade galvanized 40mm dia, cut to size all as required at site including fixing arrangement and providing appropriate size insulators to insulated pipe from foundation of air termination from pipe.
Taking up or down steel tubing of 25mm bore and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store complete with all fittings & valves etc. (Excavation shall be measured and paid separately under relevent items)
All as per item No 33 above but 20mm pipe.
All as per item No 33 above but 15mm pipe.
Material and labour and laying for tubes medium grade galvanized with all fittings laid in trenches or fixed with wall 25mm bore of tube complete all as specified and as directed.
Material and labour and laying for tubes medium grade galvanized with all fittings and fixed complete to walls and ceilings or laid in floor of size 15mm bore dia complete all as specified and as directed.
M & L in replacement of Gun metal globe or gate valve iron wheel head, screwed both ends for iron pipe of bore of 15 mm and length as required on site complete all as specified and as directed.
M & L Lagging to pipes all around with 40 mm thick bonded mineral wool performed `SNAP ON` pipe section of density 144 Kg/cum and provided with chicken mesh wire netting 25 gauge,20 mm mesh on pipe of internal dia 20 mm including rendering cement plastering 15 mm thick (1:3) on top layer of lagging all as specified & as directed .
Dismantling water tanks upto 500 Ltrs capacity and removing to store and S&F 500 Ltrs capacity rotational moulded polye thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and as directed.
S&F 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0mm-210gms./ 25mm-455gms/ 40mm - 690 gms) complete all as specified and as directed.
S&F in repairs 15mm bore CP bib tap cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe of for brass ferrule complete all as specified and as directed.
S&F 1000 ltrs capacity Rotational moulded polyethylene three layered ISI Marked water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as per specified and directed.
Supply & fixing rotational moulded polythene water storage tanks of 500 Ltrs capacity (Cylinderical vertical with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc complete all as specified and directed by Engr in Charge.
S&F 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc all asspecified and directed.
S&F 25mm dia for ball valve high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe and fixed
Taking down carefully copper/aluminum point wiring (light. Fan, socket or power) complete, incl fittings such as switches, ceiling roses, pendants, regulators, sockets etc, removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc.
M&L for point wiring in PVC casing caping with 1.5 Sqmm size multi stranded FRLS copper conductor cable 1.5 Sqm including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated FRLS cable of size 1.5 Sqmm as earth continuity conductor.(a) One light point/fan point/Ex fan point controlled by one 5 Amps switch one way
(b) One 3 pin 5 Amp switch socket outlet on independent board
(c) One 3 pin 5 Amp switch socket outlet on same board with accessories
M&L for point wiring in PVC casing caping with 2.5 Sqmm size multi stranded FRLS copper conductor cable including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated fire retardant cable of size 2.5 Sqmm as earth continuity conductor.
S&F switch piano Flush type, single pole, one way 6 amp 240 volts, complete all as specified and as directed.
S&F Socket outlet 2 in 1, 3 pin, 5 Amps, flush type complete all as specified and as directed.
S&F Switch socket combination 2 in1, 3 pin,5 and 15Amp flush type,universsal complete all as specified and as directed.
S&F Bell Push Flush type, single pole 5 amp 240 volts, complete all as specified and as directed.
S&F in repairs stepped type electronic fan regulator for ceiling fan 1200/1400mm size,230 volts,6 Amps, complete all as specified.
S&F ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body.
S&F in repairs Bell electric, Ding Dong AC 230 Volts, single pole complete all as specified and as directed.
S&F in repairs Lamp Holder, PVC/ Polycarbonate type with back plate suitable for batten fitting complete all as specified and as directed.
Supply and fix LED Lamp 15W complete all as specified and as directed.
Supply and fixing LED lights fitting 1x 22W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and as directed.
S&F in repairs Double door metallic sheet metal enclosure for DB when MCBs to be used SPN 12 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and as directed.
S&F in repairs TPN 4 way Double door metallic sheet metal enclosure with TP MCCB 100 Amp as incommer including MCB 6-32 Amps as outgoing complete, 215 V with 240Amps rated bus bar fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and as directed. .
S&F miniature circuit breaker (MCB) SPN 40 to 63 AMP rating 240V, 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection testing and commissioning.
S&F 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and as directed.
M&L sub main wiring with two run single core 6 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia PVC conduit/casing caping, medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 4 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion etc complete all as directed. Note: Two runs of 6 sqmm and one run of 4 sqmm cable and one run of casing capping shall be measured as one RM
S&F electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. Note : Old Geyser to be deposited to MES store yard.
S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3½ core complete all as specified and as directed.
Material and labour and laying of GI tubes 40mm dia light grade for cable protection on pole/road/culvert crossing and for an pedestal complete all as specified.
Supply and fix electronic meters temper proof LCD display with polycarbonate cover 230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and as directed.
M&L in repairs for Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note : The rate is ilnclusive of necessary earth work, RFR and removal etc
M & L for earthing complete with copper earth plate electrode 60cmx60cmx 3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to copper earth strip of size 20x3mm by means of brazing, bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point,duly protected with 40 mm bore light grade pipe up to main board, 20 mm bore watering pipe light grade with CI/MS funnel and wire mesh including excavation with having pit and cover in PCC 1:2:4 type B-1 including angle iron frame made of angle iron of size 40x40x6mm grouted in PCC pit for pcc cover all as specified and directed.
M&L for Earth continuity copper conductor or main earthing lead of size 20x3 mm copper strip mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/light grade GI pipe or fixed to pole or any other indicated situation for loop earthing etc. as required complete all as specified and as directed.
M&L for air termination single pointed copper rod 12mm dia and 300mm long complete all as specified and as directed.
M&L for test point terminal block made of gun metal or phosphorus bronze of size 75X75X6mm drilled and screwed includind 03 Nos 8mm dia 25mm long hex. Head screw complete all as specified and as directed.
Supply, installation, commissioning of Metal Top Deep Freezer of capacity 320 Litre, single phase 240 volt, 50 Hz complete all as specified and as directed .
S&F 300 Litre 5 Star Frost Free Multi-door Refrigerator single phase 240V, Model No - FP 313D PROTTON ROY, Steel Onyx of make Whirlpool or equivalent make with LG, Godrej, Samsung etc complete all as specified and as directed .
Supply and fix voltage stabilizer of Make V-Guard model No VG 500, 3350VA working range 170V-270V complete all as specified and as directed .
Supply, install and commissioning of kero based water heating plant of capacity 500 Litre alongwith complete connected/requirement accessories for operating kero based water heating plant with full efficiency complete all as specified and as directed . Note : quoted rates are inclusive cost of foundation)
Supply, install testing and commissioning of kero based water heating plant of capacity 500 Liters inculding accessories i.e. inlet/outlet pipes, thermostat, Glass wool insulated, oil burner including fuel storage tank of capacity 150 Ltrs , proper cover shed suitable for the boiler for operating kero based water heating plant with full effieciency complete all as specified and directed by Engr-in-Charge. (Note:-(1) Cost of foundation shall be included in quoted rate) (2) A one year warranty period is included in quoted rates.
Supply, fixing and testing of Solar Standalone Street Light system 48 hours backup including LED Street Light with in-built SCC, SPV Panel, Battery 150AH type Lithium ,HDG Tubular Pole of capacity 45W Solar SLS HSN Code 8541 24Volt of make Havells or equivalent make in CG/PHILIPS/Axxon complete all as specified and directed by Engr-in-Charge (Note:- Quoted rates are inclusive of control wiring from solar panel to control box & control box to street light).
l. Complete internal wiring of the control pannel for operating equipments by using adequate capacity single core copper wire of Havells make. The wiring shall be fitted with plastic washers for identification of each wire at various joints.
m. Panel for housing of all the equipments fabricated out 16 gauge sheet metal of adequate size to house all the equipments with enough space to reach out to any equipments for repair/replacement. The panel shall have hinged door at the front with proper locking arrangements. The housing shall be provided with a base frame fabricated out of ISMC & welded /bolted at the bottom. The housing shall be provided without space fitment of meter push buttons actuator incoming & out coming connections. The panel shall be free standing, floor mounted , totally enclosed, vermin proof, spray enamel panted in two coats of conventional shade over a coat of red oxide primer both externally & internally. The panel shall have air vents for proper ventilation.
n. Auto transformer assembly: Auto transformer coil shall be made of suitable capacity 1st class electrolytic copper strip & shall be provided class F insulation. The taping shall have to be taken at 40%, 60%,&80%. The core of the transformer shall be fabricated out of class 1st 92 grade pota sheets cut to suitable size & tightened adequately. The auto transformer shall be housed in a suitable tank fabricated out of M.S sheets of suitable thickness having a lid at top with proper arrangements for tightening with the tank. The tank shall be spray enamel painted in two coats of conventional shape over about of red oxide primer both externally & internally. The job shall also include initial filling by high grade low viscosity transformer oil up to the required level to immerse the coils fully in it, connection between the starter & auto transformer assembly shall have to be made in suitable size copper bus strips/ cable. The tank shall be fitted at the back of starter.
Suply, installation, testing and commissioning of Semi Automatic Water Softening Plant of capacity 40 LPM, including connections complete all as directed,comprising of the following :- (a) Water Source - Borewell/River Water (b) Colour - Custom (c) Inlet Flow Rate - 2.2 to 2.5 Cum/Hr complete all as specified and directed by Engr in Charge
S&F 1100 V grade heavy duty cable with pvc insulated aluminium conductor served with an inner sheathing of pvc tape and overall pvc sheathed in service connection suspended by insulating hangers not more than 1mtr apart including 4mm suspension wire one twin core cable flat or circular of size 10 sqmm complete all as specified and as directed .
Supply and fix Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 20 KVA complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 Core complete all as specified and as directed .
Earthing complete with copper plate 60×60cm ×3.15mm thick electrode buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to 20×3mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion. Note: The rate is ilnclusive of necessary earth work as exc, RF and removal etc. complete all as specified and as directed .
Supply and fixing Diesel driven Pumping Set 10 HP with base frame complete with 10 mtr flexible hose pipe as per suitable dia of pump for dewatering complete all as specified and as directed .
Supply and fixing 2 HP Monoblock Pump Electric driven with 20 mtr PVC pipe complete all as specified and as directed .
Supply and fix flexible copper cable 2.5 Sqmm 3 core PVC insulated complete all as specified and as directed .
Supply, Install, Testing and Commissioning of 'Solar Hot Water System' (Flat Plate Collector) based on indirect transfer of heat of capacity 300 LPD with electrical eating back up complete all as specified and directed by engineer-in-charge.Note: Rate of solar water system includes the cost of backup stainless steel hot water tank include the cost of civil wks,cold tanks,cold and hot water pipe lines,insulation,electical cabling etc.In case if the length of insulated hot water pipe is more than 1RM/10Ltr cap in that case cost for additional length of insulated pipe to be estimated and included. complete all as specified and as directed .
Supply & Fixing Hot water pipe duly insulated with glass wool and aluminium cladding 20 mm bore complete all as specified and as directed .
M/S Mohammad Saleem and Co
M/S GHULAM QADIR WANI AND SONS
FG CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .