| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹78,277.50Qualified Make: Honda
Model: EU30i HONDA SIEL POWER PRODUCTS LTD PLOT NO 50 YARD NO 6 NEAR SRTC YARD TRANSPORT NAGAR NARWAL JAMMU JAMMU JAMMU AND KASHMIR INDIA | Make: Honda
Model: EU30i | L1 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
4 Jun 2018, 10:00 amClosed
power generators and portable generator Power Generators And Portable Generator ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values RATED OUTPUT STARTING & RUNNING Portable Generator type Petrol start
Petrol run Petrol start
Kerosene run
Petrol start
Petrol run
Diesel start
diesel run Rated Output at unity power factor at STP (VA) 2800 450
650
750
900
1500
1800
2100
2300
2500
2800
3300
3500
5000
5500
6000
7000
7500
10000 Starting Type Recoil Recoil
Electric Self start Rated output Voltage 230 V AC 220 V AC
220 V AC and 12V
6 Amp min DC
8 Amp min DC
230 V AC WARRANTY Warranty (year) 1 1
2
3 PERFORMANCE Efficiency of the alternator (%) 80 - Noise Level of Portable Generator (dB(A)) 86 - GENERIC Make and model of engine - - Make and model of alternator - - 1/3 Provision of Voltmeter and ammeter in the output circuits yes - Dimension of Genset in (LxWxH) (mmxmmxmm) - - Dry weight (Kg) - - Period for which the Generator is capable of delivering declared output 6.9 - Fuel Tank capacity - - BATTERY Battery Ah capacity in case of Electric start Generator (Ah) - - CERTIFICATION STATUTORY REQUIREMENTS Type approval Portable Generating Set meeting the requirements of Environmental (Protection) Rules 1986
in respect of noise and emission norms
as described in STC of the Product yes - Type approval number and date - - Availability of Test Report from Central government/NABL/ILAC accredited laboratory to prove conformity to the specification for the Portable Generator Set Yes - Test Report number and date - - Name and address of laboratory - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Thirumal A 678002
Office of the Senior Divisional Engineer Divisional Railway Manager Office Palakkad Division Palakkad 1 15 EMD 2/3 Required No ePBG Required No
125777
GEM/2018/B/17951
power generators and portable generator
15 days
Kerala; Palakkad
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| power generators and portable generator Power Generators And Portable Generator ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values RATED OUTPUT STARTING & RUNNING Portable Generator type Petrol start | - | - | - |
| Petrol run Petrol start | - | - | - |
| Kerosene run | - | - | - |
| Petrol start | - | - | - |
| Petrol run | - | - | - |
| Diesel start | - | - | - |
| diesel run Rated Output at unity power factor at STP (VA) 2800 450 | - | - | - |
| 650 | - | - | - |
| 750 | - | - | - |
| 900 | - | - | - |
| 1500 | - | - | - |
| 1800 | - | - | - |
| 2100 | - | - | - |
| 2300 | - | - | - |
| 2500 | - | - | - |
| 2800 | - | - | - |
| 3300 | - | - | - |
| 3500 | - | - | - |
| 5000 | - | - | - |
| 5500 | - | - | - |
| 6000 | - | - | - |
| 7000 | - | - | - |
| 7500 | - | - | - |
| 10000 Starting Type Recoil Recoil | - | - | - |
| Electric Self start Rated output Voltage 230 V AC 220 V AC | - | - | - |
| 220 V AC and 12V | - | - | - |
| 6 Amp min DC | - | - | - |
| 8 Amp min DC | - | - | - |
| 230 V AC WARRANTY Warranty (year) 1 1 | - | - | - |
| 2 | - | - | - |
| 3 PERFORMANCE Efficiency of the alternator (%) 80 - Noise Level of Portable Generator (dB(A)) 86 - GENERIC Make and model of engine - - Make and model of alternator - - 1/3 Provision of Voltmeter and ammeter in the output circuits yes - Dimension of Genset in (LxWxH) (mmxmmxmm) - - Dry weight (Kg) - - Period for which the Generator is capable of delivering declared output 6.9 - Fuel Tank capacity - - BATTERY Battery Ah capacity in case of Electric start Generator (Ah) - - CERTIFICATION STATUTORY REQUIREMENTS Type approval Portable Generating Set meeting the requirements of Environmental (Protection) Rules 1986 | - | - | - |
| in respect of noise and emission norms | - | - | - |
| as described in STC of the Product yes - Type approval number and date - - Availability of Test Report from Central government/NABL/ILAC accredited laboratory to prove conformity to the specification for the Portable Generator Set Yes - Test Report number and date - - Name and address of laboratory - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Thirumal A 678002 | - | - | - |
| Office of the Senior Divisional Engineer Divisional Railway Manager Office Palakkad Division Palakkad 1 15 EMD 2/3 Required No ePBG Required No | - | - | - |
Exempted
4 Jun 2018
24 May 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_125777.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .