Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.8 LAccepted-AOC 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹22.1 L+₹1.4 L (6.81%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L2 | Rejected-Finance Not lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
1 May 2024, 6:00 pmClosed
GE AF BARODA
GE AF BARODA PO DARJIPURA BARODA-390022
REPAIRS / REPLACEMENT OF INTERNAL / WIRING / CEILING FAN / DESERT COOLER OF OTM ACCN AT HARNI CAMP AND HARNI AIRFIELD AREA AT AFS VADODARA
2024_MES_648684_1
8894/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF BARODA
AS PER TENDER DOCUMENTS AND NIT
3 documents required · 3 mandatory
₹500
GE AF BARODA
₹40,000
Yes
8 Jul 2024
30 Mar 2024
8 May 2024
30 Mar 2024
1 May 2024
15 Apr 2024
1 Apr 2024 - 6 Apr 2024
Amount
Identifying and rectifying the defects pertaining to internal electrification of any type and nature such as taking down defective piano switch /socket on normal/modular switch board/ceiling rose/holders/ fittings / fixtures any type, rectification of faulty electric circuits, tightening of loose connections, replacment of old u/s wiring/conduits/casing caping & connections etc, complete all as specified and directed.
Identifying/detecting defects in unserviceable wiring and rectifying the defects pertaining to internal electrification of any type and nature such as taking down defective MCBs SP /SPN/DPs/TPN any type, rectification of faulty due to loose connection in electric circuits, tightening of loose connections, replacement of U/S MCBs, U/S portion of conductor etc, complete all as specified and directed.
Identifying/detecting defects in unserviceable ceiling fan/exahaust fan/wall fan/ turbofan and rectifying the defects pertaining to genral servicing such as taking down defective fans any type, rectification of fault due to loose connection/u/s connecting wire, due to U/s capacitor, u/s due to lubrications, U/S hanging clamp etc rectified the same with tightening of loose connections, replacement of U/S conneting wire, repacement of U/S capacitor, servicing by opeing /dismentling fan cleaning the bearing and lubricating the same etc, complete all as specified and directed.
Load balancing on three phase DBs of buildings including checking of load by using amp meter/tong tester rearranging the connections with in the DBs and providing copper lugs with wires tightening of all connection and testing and verify the lthe load current on each phase in persence of JE E/M/ Engr-incharge complete all as specified and directed
NOTE FOR ITEM NO 1 to 4 :- (a) All T & P / Stationeries and labour team required comprising of sufficient trained technician (Electrician/helper ) will be provided by the contractor daily for two location ie Harni Camp and Harni Airfield Baroda area as directed. During MES mela or any other ocassion the contractor will be arrange additional menpower to rectify the complaint with justified time. b) Rep of the contractor will present in complaint cell & responsible for receiving & attending the complaints from 08.30 Hrs to 04.30 Hrs at the time of lodging the complaint. In absence of rep of Contractor penal recovery as decided by GE shall be imposed upon ontractor. (c) Cost of minor stores such as screws,clamps,insulation tapes,nuts/bolts, nail of required size, lubricating oil/grease etc shall be deemed included in the above quoted rate. However, major items such as switches, sockets, bell push, fan regulator, capacitor, wires etc shall be measured and paid separately under appropriate items of Schedule 'A'. (d) Complaints where complete replacement of circuit/point wiring required shall be measured under relevant item. (e) If contractor fails to rectify the complaint with in 24 hours after receiving, Rs 500/- per day per complaint will be penalised.
Checking/testing of Earth resistance value of earthing pits Installed inside Harni Camp and Harni Airfield Area as requirement basis as directed by Engr in Charge or as schedule and making the damaged earthing serviceable by pouring salted water into earthing or making continuity by GI strips and bringing down the resistance value within specified limits including maintenance of existing earthing by cleaning the earth chamber funnel and cleaning of vagetation surrouding earthing pit up to 2 mtr complete all as specified and directed
Note: (i) The entire station will be divided into two zones as per earthing location and the contrcator will deploy seperate team for each zone to test the resistance value of earthings in each zone to complete the process within one month. The entire process will be repeated after every six months (half yearly) upto completion of the contract. (ii) one earth testing in one season shall be measured as one job. (iii) Digital Earth tester will be arrange by the contractor at his own expense (iv) Date of testing and due date of testing is to be written on a register with sign of user rep & Engr-in Charge submitted to GE. (v) Testing and correction action is to be done within one month from date of commencement i.e. approx 200 earthings is to be completed within one month. Thereafter on half yearly basis or as directed byEngr-in charge and same is to be completed within one month.The contractor has to deploy electrician with helper and testing equipment and all the resources to complete the task within one month. (v) If any material required for improvement of resistence value which value is more than their permissible limit will be measured and paid separately
Supply only switch piano flush type single pole one way 5 Amp 240 Volts complete all as specified and directed
Supply only 5 Amps Socket 3 Pin flush type complete all as specified and directed
Supply only 15 Amps Switch 3 Pin flush type complete all as specified and directed
Supply only 15 Amps Socket 3/5 Pin flush type complete all as specified and directed
Supply only switch socket combination 2 in 1, 3 pin, 5 Amps flush type 240 Volt. complete all as specified and directed
Supply only switch socket combination 2 in 1, 3 pin, 5 and 15 Amps flush type universal 240 Volt. complete all as specified and directed
Supply only switch piano flush type single pole two way 5 Amp 240 Volts. complete all as specified and directed
Supply only Bell push flush type single pole 5 Amp 240 Volts. complete all as specified and directed
Supply only modular switch one way 6 Amps 1 module 240 Volts. complete all as specified and directed
Supply only modular switch one way 16 Amps 1 module 240 Volts. complete all as specified and directed
Supply only modular switch two way 6 Amps 1 module 240 Volts. complete all as specified and directed
Supply only modular bell push way 6 Amps 1 module 240 Volts. complete all as specified and directed
Supply only modular socket outlet 6A 3 pin 2 module 240 Volts.complete all as specified and directed
Supply only modular socket outlet 6/16A 5 pin 2 module 240 Volts. complete all as specified and directed
Supply only modular fan regulator 120W-2 module 240 Volts. complete all as specified and directed
S&F PVC pipe /conduit for laying cable / wire with clamp/ bend / tee complete all as specified and directed
Supply only Bell ding dong type, one way, 240 volts, AC, ISI marked.complete all as specified and directed
Supply only ceiling rose surface bakelite three terminal 65 x 50 mm three terminal 250/230 volts ISI marked. complete all as specified and directed
Supply only straight / Angle lamp holder PVC body complete all as specified and directed
Supply only Stepped/socket type electronic fan regulator heavy duty type A/C 240 V.complete all as specified and directed
Supply only capacitor 2.5 mfd 240V ISI mark complete all as specified and directed
Supply only capacitor 4 MFD suitable for any make, type & sweep ceiling fan, exhaust fan, cabin fan & pedestal fan complete all as specified and directed
Supply only LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed
Supply only batten integrated LED channel of 5W, 230V frequency 50/60 Hz integral sleek extruded polycarbonate LED channel with white acrylic cover, Power Factor not less then 0.9 as per Cat No BCLSB 05 WH of Bajaj or equivalent in approved make, complete all as specified and directed.
Supply only in replacement MCB single pole 6 to 30 Amps, 10KA, 230 volts 'C' series, complete all as specified and directed.
Supply only MCB single pole 32/40Amps, 10KA, 230 volts 'C' series, complete all as specified and directed.
Supply only MCB SPN 32/40Amps, 10KA, 230 volts 'C' series, complete all as specified and directed.
Supply only in replacement MCB TPN 32 to 50 Amps, 10KA, 230 volts 'C' series, complete all as specified and directed.
Supply only in replacement MCB TPN 63 Amps, 10KA, 230 volts 'C' series, complete all as specified and directed.
Taking down carefully copper / Aluminium point wiring including (light, fan, socket or power complete fittings, such as switches, ceiling roses, pendant holders, Batten holders, shades conical fan regulators, light or power sockets etc) removing materials from site and making good disturbed surfaces of walls roofs complete all as specified and directed
M&L for point wiring with FRLSH cable 1.5 sqmm PVC insulated (red for phase and black for neutral) unsheathed, multi stranded copper conductor 1100 volt grade (conforming IS 694) in and incl not less than 2mm thick PVC casing/caping ISI marked, with all accessories including one run of 1.5 Sqmm multistrand PVC insulated FRLSH stranded copper conductor cable (green colour) for earth continuity conductor to common earth dolly including all other required accessories as specified in Preamble 1 (a) to (q) of section 19 of SSR Part-II under heading "Point wiring'". fixed on walls/ceiling including PVC box surface/ flush type SS sunken boxes with PVC sheet for mounting fittings such as switches, sockets, fan regulators, etc complete covered with 3.00 mm thick plastic laminated sheet top cover all as specified and directed & making good to disturbed surface of wall to match with the existing finish etc for the following :-
One light point controlled by one one/way switch.
One Fan point controlled by one one/way switch.
One 3 pin 5 Amps socket outlet on same board with other switch.
One 3 pin 5 Amps socket outlet on independent board with cable of 1.5 sqmm size.
One bell point controlled by one way switch
One light point controlled by two way switches
M&L for point wiring with FRLSH cable 1.5 sqmm PVC insulated (red for phase and black for neutral) unsheathed, multi stranded copper conductor 1100 volt grade(conforming IS 694) in and including minimum 20 mm dia ISI marked stove enamel rigid metalic steel conduit of with all accessories, including one run of 1.5 Sqmm multistrand PVC insulated FRLSH stranded copper conductor cable (green colour) for earth continuity conductor to common earth dolly including all other required accessories as specified in Preamble 1(a) to (q) of section 19 of SSR Part-II under heading "Point wiring'".fixed on walls/ceiling including wooden box and connected to flame proof switch, sockets etc all as specified and directed & making good to disturbed surface of wall to match with the existing finish etc for the following :-
One light point controlled by one one/way switch.
One Fan point controlled by one one/way switch.
One 3 pin 5 Amps socket outlet on same board with other switch.
One 3 pin 5 Amps socket outlet on independent board with cable of 1.5 sqmm size.
Material and labour for concealed point wiring with using 2 x 1.5 Sqmm (nominal area) stranded copper conductor single core, PVC insulated (FRLSH) & unsheathed cable, 1100 volts grade as per IS 694 for Phase and Neutral, 1x 1.5 Sq mm (nominal area) stranded copper conductor single core conductor, PVC insulated (In Green colour)& unsheathed cable as in earth wire connected to common earth dolly in concealed rigid PVC conduit size not less then 20mm dia as per site requirement of suitable size all as specified and directed with and including providing new SS sunken box and Moduler cover plate for fixing of switch socket, fan regulators etc and incl all accessories complete all as specified and directed for the following :-
One light point controlled by one one/way switch.
One Fan/Exahaust fan point controlled by one one/way switch.
One 3 pin 5 Amps socket outlet on same board with other switch.
One 3 pin 5 Amps socket outlet on independent board
One bell point controlled by one one/way push button
One light point controlled by two way switches
Description all as per item No 38.00 here-in-before but for power point 3 pin switch socket 15 Amp with with FRLSH cable PVC insulated copper conductor cable multistrand unsheathed 2.5 Sqmm(conforming IS 694) on independent board including one run of 2.5 Sqmm multistrand PVC sheathed copper conductor cable for earth continuity in complete all as specified and directed.
M & L for Power point 3 pin switch socket 15 Amp with with FRLSH cable PVC insulated copper conductor cable multistrand unsheathed 2.5 Sqmm on independent board including one run of 2.5 Sqmm multistrand PVC sheathed copper conductor cable for earth continuity in and including PVC casing and caping of appropriate size and best quality ISI marked, including all other required accessories as specified in preamble 1(a) to (q) of Section-19 of SSR Part-II under heading "Point wiring" fixed on wall including flush SS sunken box/ PVC terminal boxes on surface for mounting fittings like switch, sockets etc covered with 3.00 mm thick plastic laminated sheet top cover complete all as specified and directed.
Description all as per item No 40.00 here-in-before but wiring with with FRLSH cable 4 sqmm multistranded copper conductor unsheathed and 4 sqmm copper conductor unsheathed cable as earth continuity conductor for one 3 pin 15 Amps socket outlet point on independent board complete all as specified and directed.
Note for items No 36.00 to 41.00 : (i) The quoted rates shall be deemed to be inclusive for any cutting chases in brick walls/pillars etc for fixing of suncken boxes and flush it & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with existing surfaces and provision of covering modular sucken box and modular cover plate of any shape . (ii) Fittings like switches sockets regulators, lamp holders light fittings shall be measured and paid for separately under respective items of BOQ. (iii) The size of conduits shall be determined on permissible No of runs of wires as specified in SSR part I (2010) However minimum size of conduits shall be 20 mm dia (medium grade).
The contractor shall be responsible for doing point wiring as per the instruction of concerned JE(E/M) and AGE(E/M). Being maintenance work Contractor shall carry out single point wiring or associated work as per the direction of concerned JE(E/M). Delay in any work more than of 3 days after allocation will invite recovery at the double rate of quoted rate. Contractor shall depute a team of electrician and helper on daily basis at Darjipura Main receiving station to carry out maintenance within stipulated time.without fail
M & L for sub main wiring using with FRLSH cable two single core 6 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing in and including PVC Casing Caping/PVC Conduit or in existing concealed conduit(as required & directed by Engr-in-Charge)accessories like bends, tee, etc fix on wall and ceiling and connecting to earth dolly and including 6 Sqmm earth wire, PVC insulated & unsheathed complete all as specified and directed. Note: (i) Two runs of 6 sqmm and one run of 6 sqmm earth wire and one run of PVC conduit casing caping shall be measured as one unit. (ii) Necessary plastering to the disturbed surface of wall and distempering /white washing to match the existing colour shall deemed to be included in the quoted rate.
M & L for sub main wiring using with FRLSH cable two single core 4 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing in and including PVC Casing Caping/PVC Conduit or in existing concealed conduit(as required & directed by Engr-in-Charge)accessories like bends, tee, etc fix on wall and ceiling and connecting to earth dolly and including 6 Sqmm earth wire, PVC insulated & unsheathed all as directed. Note: (i) Two runs of 4 sqmm and one run of 4 sqmm earth wire and one run of PVC conduit casing caping shall be measured as one unit. (ii) Necessary plastering to the disturbed surface of wall and distempering /white washing to match the existing colour shall deemed to be included in the unit rate quoted .
S&F switch piano flush type single pole one way 5 Amp 240 Volts. Complete all as specified and directed
S&F 5 Amps Socket only 3 Pin flush type Complete all as specified and directed
S&F 15 Amps Switch only 3 Pin flush type Complete all as specified and directed
S&F 15 Amps Socket only 3 Pin flush type Complete all as specified and directed
S&F switch piano flush type single pole two way 5 Amp 240 Volts. Complete all as specified and directed
S&F Bell push flush type single pole 5 Amp 240 Volts. Complete all as specified and directed
S&F modular switch one way 6 Amps 1 module 240 Volts. Complete all as specified and directed
S&F modular switch one way 16 Amps 1 module 240 Volts. Complete all as specified and directed
S&F modular switch two way 6 Amps 1 module 240 Volts. Complete all as specified and directed
S&F modular bell push way 6 Amps 1 module 240 Volts. Complete all as specified and directed
S&f modular socket outlet 6A 3 pin 2 module 240 Volts. Complete all as specified and directed
S&f modular socket outlet 6/16A 5 pin 2 module 240 Volts. Complete all as specified and directed
S/F ceiling rose surface bakelite three terminal 65 x 50 mm three terminal 250/230 volts ISI marked. Complete all as specified and directed
Supply and fixing in repair Straight /Angle bulb holder pvc body complete.Make: Anchor, kolors, material to be supplied as per demand of qty Complete all as specified and directed
Supply and fixing repair in Stepped/socket type electronic fan regulator heavy duty typeA/C 240 V.Complete all as specified and directed
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed
S/F in repair Load line 6 way segrigated Vertical type(VTPN DB) DB double door, duly powder coated 415 volt with provision for 125 Amps MCCB as incomer and 200 Amp rated bar FP as incomer and SP/TP as outgoing complete all as specified and directed
S/F in repair Load line 4 way load line segrigated Vertical type(VTPN DB) DB double door, duly powder coated 415 volt with provision for 125 Amps MCCB as incomer and 200 Ams rated bar FP as incomer and SP/TP as outgoing complete all as specified and directed
S/F in repair 8 way TPN DB DB double door, duly powder coated 415 volt and 200 Amp rated bar FP as incomer and SP/SPN/TPN as outgoing complete all as specified and directed
S/F in repair sheet metal enclosure Double door, duly powder coated for single pole and neutral 12 way DB 240 volts, 100 Amp rated bus bar. complete all as specified and directed
S/F in repair sheet metal enclosure Double door, duly powder coated for single pole and neutral 08 way DB 240 voilts, 100 Amp rated bus bar. complete all as specified and directed
S/F in repair sheet metal enclosure Double door, duly powder coated for single pole and neutral 04 way DB 240 voilts, 100 Amp rated bus bar.complete all as specified and directed
S/F in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with one single MCB SP 20 Amps. complete all as specified and directed
S/F in repair MCB's SP 40 Amp to 63 Amp 240 Volts 9 KA rupturing capacity conforming to IS-8828 of the undermentioned type and ratings complete all as specified and directed
S/F in repair MCB SP up to 32 Amp 240 Volts 9 KA rupturing capacity C curve conforming to IS-8828 of the undermentioned type and ratings complete all as specified and directed
S/F in repair MCB SP & N up to 63 Amp 240 Volts C Curve complete all as specified and directed
S/F in repair MCB SP & N up to 32 Amp 240 Volts C Curve complete all as specified and directed
S/F in repair MCB TPN 40 To 100 AMP 240 Volts C Curve complete all as specified and directed
S/F in repair MCB TP up to 63 Amp 415 Volts C Curve complete all as specified and directed
S&F in replacement PVC rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 100mm x 100mm x 50 mm complete all as specified and directed.
Description all as per item No 75.00 here-in-before but for size 175x100x50 mm deep
Description all as per item No 75.00 here-in-before but for size 200x150x50 mm deep
Description all as per item No 75.00 here-in-before but for size 250x200x50 mm deep
Description all as per item No 75.00 here-in-before but for size 350x200x50 mm deep
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet,10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed
Supply and fixing LED light fittings small 6 watt round/square type white/yellow complete with choke/driver complete all as specified and directed
Supply and fixing recess mounted down lighter 6 Watts complete all as specified and directed yellow/white AS Per Sample . complete all as specified and directed
Supply and fixing LED Street light fittings 30 watt, 220 V AC complete with driver, holders & LED lamp suitable for wall/roof/ ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed
Supply only LED bulb Lamp 09 Watts Retrofit B22 holder type base wth polycorbonate diffuser and alluminiun heat sink.complete all as specified and directed
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed
Supply and fixing earth industrial plug top for socket for industrial socket metal glad suitable for 20 Amps metal glad MCB DB complete all as specified and directed
Supply and fixing earth industrial socket metal glad suitable for 20 Amps 240 volts metal glad MCB DB complete all as specified and directed
Supply only FR electrical insulation tape nominal size 0.125mm thickness x1.8 cm width x15 mtr length as IS CODE 1728 As per sample complete all as specified and directed
S & fix in replacement Plug top 15 Amps 240 Volt. complete all as specified and directed
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1400 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed
Supply and fix exhaust fan, steel body AC single Phase. 230 V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed
M&L for painting enamel white paint by spraying on ceiling fans/exhaust fan complete in situ with synthetic enamel paint by spraying including filling cavities with fine finishing surface by filler one coat after removing/cleaning all dust/dert etc including taking down/ refixing complete all as specified and directed Note:- marking/ numbering with MES No/ Qtr no included in item rates, no extra payment shall be made for marking /numbering.
M & L for rewinding of ceiling fans 1200/1400mm sweep, taking out fan from from site and transported to local work shop, dismantling and strip opening and removal of burnt winding wire, rewinding the fans with suitable size of copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc 6 month warranty period shall given by the dealer/contractor after repair, complete as reassembling taking down and refixing at site and shifting/transporting to wksp and back including testing complete all as specified and directed
M & L for rewinding of Exhaust fan 300 mm sweep,taking out fan from from site and transported to local work shop, dismantling and strip opening and removal of burnt winding wire, rewinding the fans with suitable size of copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc 6 month warranty period shall given by the dealer/contractor after repair, complete as reassembling taking down and refixing at site and shifting/transporting to wksp and back including testing complete all as specified and directed
M & L for rewinding of Exhaust fan 450 mm sweep,taking out fan from from site and transported to local work shop, dismantling and strip opening and removal of burnt winding wire, rewinding the fans with suitable size of copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc 6 month warranty period shall given by the dealer/contractor after repair, complete as reassembling taking down and refixing at site and shifting/transporting to wksp and back including testing complete all as specified and directed
M & L for rewinding of Cabin fan 400 mm sweep, taking out fan from from site and transported to local work shop, dismantling and strip opening and removal of burnt winding wire, rewinding the fans with suitable size of copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc 6 month warranty period shall given by the dealer/contractor after repair, complete as reassembling taking down and refixing at site and shifting/transporting to wksp and back including testing complete all as specified and directed
M & L for rewinding of air circulator 600 mm sweep,taking out fan from from site and transported to local work shop, dismantling and strip opening and removal of burnt winding wire, rewinding the fans with suitable size of copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc 6 month warwanty period shall given by the dealer/contractor after repair, complete as reassembling taking down and refixing at site and shifting/transporting to wksp and back including testing complete all as specified and directed
M & L for rewinding of flame proof exahaust fan size 300mm sweep, taking out fan from from site and transported to local work shop, dismantling and strip opening and removal of burnt winding wire, rewinding the fans with suitable size of copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc 6 month warranty period shall given by the dealer/contractor after repair, complete as reassembling taking down and refixing at site and shifting/transporting to wksp and back including testing complete all as specified and directed
M&L for Bearinng of celing fan suitable for 1200mm sweep/14mm sweep complete all as specified and directed
M&L for Bearinng of exahust fan 300mm/450mm sweep suitable for 1200mm sweep/14mm sweep complete all as specified and directed
M&L for Bearing air circulator/cabin fan suitable 600mm fan/400mm cabin fan complete all as specified and directed
S & F MS clamps (Standard size as per site) with rubber real with MS nut, bolts, check nut & split pin complete all as specified and directed
S&f 3 PHASE Socket 415 volt complete all as specified and directed
S&f 3 PHASE Top 415 volt complete all as specified and directed
S&F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed.
S&F flame proof/weatherproof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth switch socket combination socket 16 Amp 240 Volts complete all as specified and directed
S&F tube light fitting 1 x 20 Watt flame proof type FLP-WP made of aluminium alloy LM6, with electronic ballast, bipin holders, connector block, etc. complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable of suitable size 4 feet complete all as specified and directed.
Supply and fixng Hylum sheet Size 7” x 9”x3 mm thick with Brass screw and washers with necessary slots required for mounting the fixtures complete all as specified and directed
Supply and fixng Hylum sheet Size 9” x 6”x3 mm thick with Brass screw and washers with necessary slots required for mounting the fixtures complete all as specified and directed
Supply and fixng Hylum sheet Size 6” x 6”x3 mm thick with Brass screw and washers with necessary slots required for mounting the fixtures complete all as specified and directed
Supply and fixng Hylum sheet Size 9” x 11”x3 mm thick with Brass screw and washers with necessary slots required for mounting the fixtures complete all as specified and directed
Supply and fix 4 sq mm 3 core flexible copper cable for maintenance of geyser, and cooling appliances complete all as specified and directed
Supply and fix driver for 150 watt led flood light any make any type complete all as specified and directed.
Supply and fix driver for 25/30 watt LED street light any make any type complete all as specified and directed.
Supply and fix LED flood light 50 watt complete all as specified and directed.
Supply and fix LED flood light 150 watt complete all as specified and directed.
Supply and fix knob as per sample for flame proof switch/DBs complete all as specified and directed.
Supply and fix 23/.0076 sq mm 2 core flexible copper cable for maintenance of light/ fan etc complete all as specified and directed
S&F 400 watt HVSV lamp complete all as specified and directed
S&F 400 watt capacitor/codenser for 400 watt HVSV lamp complete all as specified and directed
S&F 400 watt choke(ballast) suitable for 400 watt HVSV lamp complete all as specified and directed
Supply and fix Bollard light 10 watt LED based bollard with MS pipe housing with glare free PMMA diffuser,IP65,H= 800 MM complete all as specified and directed. NoteL:- Necessary excavation/ cabling work/2 mtr length of wire and PCC work of size 250mm x 250mm x 15 mm included in item rate no extra payment should be made by Department.
M/s Jagdish Machinery Stores
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .