| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹11.4 LAccepted-AOC 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | 1 | Accepted-AOC LOWEST | |
| 2 | 2₹13.4 L+₹1.9 L (16.3%)Rejected-AOC 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | 2 | Rejected-AOC REJECTED |
Tender Value
Refer Docs
EMD Value
₹24,000
Closing Date
30 Sept 2020, 6:00 pmClosed
CWE AHMEDABAD
CWE AHMEDABAD
REPAIR/ MAINTENANCE OF HT VCB AND TRANSFORMER AND CONNECTING ACCESSORIES UNDER GE AHMEDABAD
2020_MES_374230_1
86926
Open Tender
Civil Works - Others
Item Rate
120 days
ARMY AREA AHMEDABAD
refer tender
6 documents required · 6 mandatory
₹500
GE ARMY AHMEDABAD
₹24,000
Yes
10 Nov 2020
3 Sept 2020
1 Oct 2020
3 Sept 2020
30 Sept 2020
18 Sept 2020
3 Sept 2020 - 12 Sept 2020
Amount
Material and labour for dismantling Vacuum circuit breakers of rating upto 630A,11KV, 3Ph, by removing incoming and outgoing cable connections, removing busbars, current transformers, moving and fixed contacts cleaning all the parts with CTC, servicing of spring charge motor, checking the healthiness of tripping and closing coils,improving the insulation resistance value and reassembling the same all as specified and directed by Engineer-in-Charge. Note : Work should be carried out in presence of competent service Engineer.
M&L for calibration of following relays, setting the relays for the fault levels as directed by Engineer-in-charge and testing the operation of Vacuum circuit breaker after installation of relays by simulating different types of faults all as directed by Engineer - in- charge. Note: a) Work should be carried out by competent service Engineer and report should be submitted on post completion of calibration.
Earth fault relay
Over current relay
M&L Energy Audit by accredited from of B.E.E Bureau of Energy Efficiency,(Govt of India) have sound experience and experties in this field ,to conduct energy audit of Ahmedabad cantt sector wise/area wise specifically
(a)Transformers loading pattern: measurement of electrical parameters and analysis to find loading, eficiency,rationalization,maintenance practices etc.
b) Study of electrical bills: for PF pattern, contract demand, demand charges,night tariff, load patter etc.
(c) Measurement of major utility equipment motors: and study loading pattern rationalization, inter changeability, maintenance practices, application study, type and size of motor, suggesting any possible energy saving devices to be connected etc.
(d) Power factor study : capacitors installation and their performance evaluation, system, PF at various levels and at various levels and at various load pattern, study and analysis.
(e) Pumps: Major pumps shall be covered for opimization, maintence practices etc. We shall measure flow of Pumps with the help ultrasonic flow meter. Results of actual flow agains rated flow and actual power against ated power shall give us performance evaluation of pumps and motors system.
(f) Lighting :n Study of type of installation,lux level at all levels, availability of natural light, illumination pattern etc.
(g) DG Det: Derivation of LITERS/KW based on limited period trials taken and suggest for improvement after trial.
Recommended also in following two categorie.
(i) Operational: It is a suggestion in which improvement on specific area/sector/equipment an be done including moderate modification, changes in process parameters, changes in design, and changes in men power. The sole purpose is to save energy without much investment. this may take less time to implement.
(ii) Project: It is a suggestion 8in which help of external agencies/finance is including retrofitting, replacement, new addition of eauipments/instruments, change in technology etc and it may take more time Ahmedabad Military Station including Transformer loang pattern, study of eloectrical bills, measurement of major utility equipment motors, P.F study, evaluation of pumps water system, lightng, DG Set evaluation trials etc.
Dehydration including filteration of transformer oil in existing transformer as installed by dehydration and filteration plant including testing of sample before and after dehydration and filteration complete all as specified and directed. (The dielectric strength to be achieved 60 KV at 2.5 mm gap after completion of de-hydration and filteration).
S&F LT bushings with gun metal threaded studs of suitable lengths including metal rings/nuts/bolts/ washers, rubber rings etc complete for Transformer 11/0.433 KV, capacity of 160-200 KVA af any make all as specified and directed by Engineer in charge.
S&F LT bushings with gun metal threaded studs of suitable lengths including metal rings/nuts/bolts/ washers, rubber rings etc complete for Transformer 11/0.433 KV, capacity of 250 - 315 KVA af any make all as specified and directed by Engineer in charge.
S&F HT bushings with gun metal threaded studs of suitable lengths including metal rings/nuts/bolts /washers, rubber rings etc complete for Transformer 11/0.433 KV, capacity of 160-200 KVA af any make all as specified and directed by Engineer in charge.
S&F HT bushings with gun metal threaded studs of suitable lengths including metal rings/nuts/bolts /washers, rubber rings etc complete for Transformer 11/0.433 KV, capacity of 250 - 315 KVA af any make all as specified and directed by Engineer in charge.
Supply and replace breather assembly with dry silca gel for transformer 11/0.433 KV, capacity of 160 - 200 KVA all as specified and directed by Engineer - in - charge.
Supply and replace dry silca gel of transfermer breather all as specified and all as directed by Engineer - in - charge.
Preparation of old painted surfaces including painting of existing transformer and cooling coils/fins of transformers of following capacities by removing oil marks using chemical or hot blow lamp. Spray painting to prepared surfaces using antirust synthetic enamel paint of superior quality and colour as approved by GE/AGE E/M as per standard Engineering practice with two coats, Writing SM No, MES No, Make and capacity with white paint having height not less than 2.5 cm and width not less than 1cm upto 200 KVA complete all as directed by Engineer - in - charge.
All as per srl item 12 above but above 200 KVA upto 315 KVA.
All as per srl item 12 above but above 315 KVA upto 500 KVA.
Supply and fixing LT side porcelain insulator of transformer for both male and female complete all as specified and as directed by Engr - in - charge.
Supply and fixing HT side porcelain insulator of transformer for both male and female complete all as specified and as directed by Engr - in - charge.
Supply, Filling and top up the new transfermer oil of approved make all as specifaied and all as directed by Engineer - in - charge. Make : Power oil
M&L for dismantling the HT under ground cable of size 95 sq mm fom its location and keeping in self costody shall become the proprerty of the contractor after credit recovered by the department.
Supplying, Laying, Jointing, Testing and comissioning of HT UG cable, XLPE ,screened ,insulated ,armoured and PVC bedded ,11000 volts grade ,(heavy duty) earthing system with aluminium conductor of size 3 core 95 sq mm conforming to IS 7098 (part II), laid in trenches, fixed to walls or passing through pipes and connecting up all as specified and directed by Engr-in-charge. Make : Fort Gloster/Universal/ Asian cable/Havell's/ Plaza/Nicco.
Supplying, Laying, Jointing, Testing and comissioning of HT UG cable, XLPE ,screened , insulated, armoured and PVC bedded ,11000 volts grade,(heavy duty) earthing system with aluminium conductor of size 3 core 120 sq mm conforming to IS 7098 (part II), laid in trenches, fixed to walls or passing through pipes and connecting up all as specified and directed by Engr-in-charge. Make : Fort Gloster/Universal/ Asian cable/Havell's/ Plaza/Nicco.
Material and labour for dismanteling old cable end termination and supply and fixing Cable end termination joint heat shrinkable outdoor type suitable for 11KV, 95 Sqmm XLPE, 3 Core power cable aluminium conductor. Make : M-Seal/ Raychem/Denson/Mahindra
Material and labour for dismanteling old cable straight through joint and supply and fixing Straight through cable joint heat shrinkable type suitable for 11KV, 120 Sqmm XLPE, 3 Core power cable aluminium conductor including necessary exc and retruning filling in existing cable route as directed. Make : M-Seal/ Raychem/Denson/Mahindra
Material and labour for dismanteling old cable end termination and supply and fixing Cable end termination joint heat shrinkable outdoor type suitable for 11KV, 120 Sqmm XLPE, 3 Core power cable aluminium conductor. Make : M-Seal/ Raychem/Denson/Mahindra
Material and labour for dismanteling old cable straight through joint and supply and fixing Straight through cable joint heat shrinkable type suitable for 11KV, 95 Sqmm XLPE, 3 Core power cable aluminium conductor including necessary exc and retruning filling in existing cable route as directed. Make : M-Seal/ Raychem/Denson/Mahindra
Supply, fix and connecting of aluminium conductor steel reinforced, any cross sectional area complete all as specified and as directed
Dismantling cross arms of any size from the existing poles by disconnecting from the insulators and keeping at side for re-use /re-fixing complete all as specified and directed by Engr-in-charge.
Material and labour for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one coat of red oxide primer and two coat of aluminium paint including preparation of new steel surfaces all as directed.
Fixing only cross arms, MS channels etc, retrived item No 19 here-in-before with nuts, bolts, washers all as specified including two coats of aluminium paints over one coat of red oxide primer complete duly scraping the existing paints complete all as speciafied and directed by Engr-in charge.
Material and labour for dismanteling old U/S AB switch and Supply and install switch air break, vartically gang operated triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating 200 amps 11000 volts, including GI pipe and all other accessories all as specified and as directed.
S&F Pin type, porcelain, vitreous, brown insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade including dismantling of old insulators all as specified and as directed.
M&L danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M. S. clamps bolts and, nuts of approved size for HT 25 x 20cm size including dismantling of old board complete all as specified and as directed.
M&L for servicing of existing AB switch 11 KV, 3 pole with fuse unit fixed on four/two pole structure at variour location in cantt area by applying conducting jelly on knife and mouth of insulator, thoroughly cleaning and checking of all macanically operated parts and apply grease where necessary for easily operatig the device from ground level including replacing of minor spares like nut, bolts and washers etc complete all as directed.
Excavation in soft / loose soil in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out complete.
Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point
M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009) Note : Sand shall be fined sand as specifed and punned thickness shall be measured and paid.
Supplying and laying factory made un-reinforced precast concrete cable cover class HV type 1 flat, size 300mm x 180mm x 40mm complete laid in trenches over sand for cable protection complete.
M&L for painting of MS swaged poles 11 m long including brackets/clamps etc with best quality aluminium paint, making alternate black & yellow colour bands of 30 cms width upto a height of 1.5 m from pole coping with synthetic enamelled paint complete.
Steel tubes ISI marked light grade galvanised with all fittings fixed to walls / poles as required of following sizes:-.
80 mm bore
100 mm bore
150mm bore
Labour & tools for horizontal boring through road / path / floor for passing UG cables by using trench less technology for laying complete all as directed by Engr-in-charge. Note : GI / DWC pipe will be measured and paid seperately.
Material and labour earthing with steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing).
Supply, laying and testing of LT UG cable, XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sqmm 3.5 core.complete all as specified and directed. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Sch 'A'.
M&L for straight through,heatShrinkable Lt cable joint kit outdoor type including jointing kits complete for making joints suitable for aluminium conductor cable of size 3.5/ 4 core 150 to 185 sq.mm.Make :- M-SEAL / BIRLA 3 M LTD / DENSON /RAY CHEM
M & L for laying stone graded coarse aggregate of size 40 mm for foundation filling at sub station two pole/ four pole complete all as specified and directed by engr-in charge.
M & L for laying stone graded coarse aggregate of size 20 mm for foundation filling at sub station two pole/ four pole complete all as specified and directed by Engr-in-Charge.
Supply and fixing for Elastomer Insulating Mats for Electrical Purposes Class A/voltage grade upto 3.3 KV (AC) as per IS : 15652:2006 with ISI mark of thickness 2.00 mm+ 10% of approx width 1 mtr along with suitable adhesive /chemibound resin waterproofing compound and sealing material all as per manufacturers' recommendations. Make: Electromat or equivalent approved by GE
ALBA AC AND REF SERVICES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .