Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.3 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹11.1 L+₹2.8 L (33.3%)Rejected-Finance | L2 | Rejected-Finance Rejected being L2 |
Tender Value
Refer Docs
EMD Value
₹23,000
Closing Date
29 Mar 2022, 6:00 pmClosed
GE (Army) Central Jodhpur
GE (Army) Central Multan Line Army Area Jodhpur
PROVN OF SITE READINESS FOR INSTALLATION OF NETWORK FOR SPECTRUM INTERNET PROTOCOL MULTIPROTOCOL LABEL SWITCHING NFS IP MPLS EQUIPMENT AT ALL UNITS HEAD QUARTERS AND PROVN OF GEYSERS IN BLDGS OF CORPS SIG REGT IN JODHPUR CANTT UNDER (9087/E8)
2022_MES_513409_1
GE/J/A- OF 2021-22 (9087/E8)
Open Tender
Civil Works
Item Rate
180 days
GE (Army) Central Multan Line Army Area Jodhpur
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (Army) Central Jodhpur
₹23,000
6 Apr 2022
12 Mar 2022
31 Mar 2022
12 Mar 2022
29 Mar 2022
17 Mar 2022
Amount
Note:- All items in BOQ are for "Materials and labour / Supply and fix" and to be executed in "Repairs unless otherwise specifically mentioned as "Supply only" or Fixing only" in BOQ Bidders are required to quote their rates accordingly
M&L for sub main wiring with PVC insulated and unsheathed 4 Sq mm single core multistrandred copper conductor cable passing through in and including PVC conduit fixed on surface or conceled in wall as per site requirement (ISI marked) and conduit accessaries fixed on surface of wall, ceiling etc, making good the distrurbed surface, incl 2.5 Sq mm single core copper conductor cable PVC insulated and unsheathed as earth wire, complet all as specified and as directed. Note :- Two runs of cable 4 Sqmm and One run of 2.5 Sqmm along with conduit shall be measured as unit length.
M&L for Metal clad box complete with plug top and MCB SP 20 Amps, complet all as specified and as directed. Make : Legrand/ Schneider/ ABB.
M&L for writing letters in black colour paint 40mm width, complet all as specified and as directed :- (a) Manufacturer srl No. (b) Date set to work. (c) Initial cost. (d) PRB page No. (e) Location
M&L for concealed Point wiring complete with 1.5 Sq mm single core multi stranded copper conductor PVC (FRLS) insulated unsheathed cable confirming to IS-694,1100 Volts grade ISI Marked, class V in concealed PVC conduit (ISI Marked) not less than 20mm dia heavy duty with accessories etc and including sunken pressed steel terminal boxes in wall, including 1.50 Sq mm PVC insulated unsheathed stranded copper conductor (FRLS) cable for common earth and connecting to earth dolly material and labour for, complet all as specified and as directed. Note- rates of chasing/cutting & making goods shall be included in the unit rate :- (a) One light point controlled by one-one way switch.
(b) One ceiling fan/Exhaust fan point controlled by one, one way switch through Regulator.
(c) One three pin 5/6 Amp socket on same board with other switches.
(d) One three pin 5/6 Amp socket on independent board.
All as per item No. 5.00 above but with 2.5 Sq mm cable for one 3 Pin 16 amp socket on independent board including one 1.5 sqmm copper conductor multi stranded green colour PVC insulated unsheathed cable 1100 volts grade as earth wire upto common earth & connected to earth dolly complete all as specified and as directed by Eng.-in-charge.
S&F switch piano flush type single pole one way 6 Amp (ISI Marked), complet all as specified and as directed. Make : Havells/ Anchor
S&F switch piano flush type single pole one way 16 Amp (ISI Marked), complet all as specified and as directed. Make : Havells/ Anchor
S&F socket outlet 2 in 1, 5 pin, 6 Amp flush type (ISI Marked), complet all as specified and as directed. Make : Havells/ Anchor
S&F socket outlet 2 in 1, 6 pin, 6 and 16 amp flush type (ISI Marked), complet all as specified and as directed. Make : Havells/ Anchor
M&L for Ceiling rose, 3 terminal/PVC/ polycarbonate, isolated body, complet all as specified and as directed. Make : Havells/ Anchor
M&L for Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fitting including 9W LED Lamp, complet all as specified and as directed. Make : Havells/ Anchor/ Leader
S&F socket type (2 Module) electonic fan regulator flush type (ISI Marked), complet all as specified and as directed. Make : Havells/ Anchor
S&F sheet metal enclosures 240 volt with suitable rated bus bar for double door IP-42 DB's suitable for one MCB SPN as incoming and 2 MCB SP as out going,SPN 4Way, complete all as specified and as directed by Engr-in-charge. Make : Havells/ Legrand/ ABB
S&F sheet metal enclosures 240 volt with suitable rated bus bar for double door IP-43 DB's suitable for one MCB SPN as incoming and 6 MCB SP as out going SPN 8 way, complete all as specified and as directed by Engr-in-charge. Make : Havells/ Legrand/ ABB
S&F MCB Single pole"C" series 5-32 Amps (ISI marked), complet all as specified and as directed. Make : Havells/ Legrand/ ABB
S&F MCB Single pole & neutral "C" series 40 Amps (ISI marked), complet all as specified and as directed. Make : Havells/ Legrand/ ABB
S&F MCB Single pole & neutral "C" series 63. Amps (ISI marked), complet all as specified and as directed. Make : Havells/ Legrand/ ABB
S&F anti staic matting (3 layers thickness 2 mm), anti fatigue, slip resistance, wear reisistance and suitable for hight voltage environments, complet all as specified and as directed by Engr-in-charge.
S&F Environmet & Dust Contain and anti rodent mesaures, complet all as specified and as directed.
S&F FFE (Portable Dry powder Extinguisher stored pressure type-4 Kg), body and inner shell made of mild steel sheet and neck ting made of leaded tin bronze and brass forging , plunger made of brass as per IS 2171, complet all as specified and as directed by Engr-in-Charge.
M&L for geyser 25 Ltr horizontal type storage type (ISI Marked) , Energy efficient , BEE 5 Star rated , including fixing arrangement by means of drilling hole in wall , grouting rack bolts fastner 100 mm long and making good to distrubed surface, complete all as specified and as directed. Make : CG/ Bajaj/ Bluestar/ Havells
M&L for power point wiring/ sub main wiring with PVC insulated and unsheathed 2.5 Sqmm single core multistrandred copper conductor cable passing through in and including PVC conduit MMS, fixed to walls, ceiling etc, making good the distrurbed surface, incl 1.0 Sqmm single core copper conductor cable PVC insulated and unsheathed as earth wire, complete all as specified and as directed. Note : - Two runs of cable 1.5 Sqmm and one run of 01 Sqmm along with conduit shall be measured as one unit length.
S&F Chromium plated brass stop valve 15mm (ISI Marked), high pressure both end screwd, complete all as specified and as directed.
S&F PVC connection 15mm dia, 450mm long with brass alloy crome plated nuts, suitable for hot and cold water application (ISI Marked), complete all as specified and as directed.
M&L for GI tube 'Medium grade', 15mm bore, galvanised iron, with all fittings and fixed complete to wall and ceiling or laid on floor, complete all as specified and as directed. Make : Tata/ Jindal/ Surya/ Prakash
M&L for cutting in existing location and position galvanised pipe upto 50mm dia, inserting tee of required size and connecting 15 mm dia pipe, complete all as specified and as directed.
S&F Chromium plated brass bib tap fancy type of size 15mm (ISI Marked), complete all as specified and as directed.
Note:- The contract sum shall be arrived at after duducting amount of schedule of "Credit" from the Total quoted amount
Surendra Singh
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .