Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹82.1 LAccepted-AOC | L1 | Accepted-AOC Accepted.quoted amount 6954994 | |
| 2 | L2₹77.5 L+₹7.9 L (11.4%)Rejected-AOC FAHIM ARCADE DOOR NO 92 3RD FLOOR BROADWAY KOCHI 682 031 | ERNAKULAM | KERALA | 682031 | L2 | Rejected-AOC Rejected |
Tender Value
₹72.3 L
EMD Value
₹50,000
Closing Date
7 Jul 2023, 6:00 pmClosed
Executive Engineer
Electrical Division Kannur Vydyuthi Bhavanam Kannur 670002
Supply of 1.1kV Aerial Bunched Cable with accessories and Constructing 13.73 Km of LT overhead line with LTABC at different locations under Electrical Division,Kannur
2023_KSEB_582218_1
EE/ED-KNR/2/2023-24/ET
Open Tender
Electrical Works
Turn-key
120 days
Kannur
Please refer Tender documents.
7 documents required · 7 mandatory
₹5,900
Yes
₹50,000
Yes
8 Dec 2023
17 Jun 2023
11 Jul 2023
17 Jun 2023
7 Jul 2023
17 Jun 2023
Amount
Material
Satellite Connector for LT ABC 3X70 + 1X50 + 1X16 Tap 2.5-35 Sqmm(50 Sqmm)(4 way)
Pole Top Distribution Box LT Outdoor 415 V 25 kW (For Connection from ABC)
End Cap for LT ABC 16 Sq mm
End Cap for LT ABC 50 Sq mm
End Cap for LT ABC 70 Sq mm
Cable Tie UV Plastic Heavy Duty 250 mm Length
FUSE UNIT 415 V 100 A PORCELAIN
IPC FOR LT ABC3X70+1X50+1X16 Tap 16 - 95 sq .mm
INSULATION TAPE for ABC
Pre-Insulated Midspan Joints and Terminal Lugs 16 Sq.mm
Pre-Insulated Midspan Joints and Terminal Lugs 50 Sq.mm
Pre-Insulated Midspan Joints and Terminal Lugs 70 Sq.mm
Pipe GI 40 mm dia -2.5 m Length( Earth Pipe)
Aerial Bunched Cable LT 3x70 + 1x16 + 1x50 sq.mm (Insulated Messenger)
Stainless Steel Strap 20 mm x 0.7 mm
IPC FOR LT ABC3X70+1X50+1X16 Tap 4 - 50 sq .mm
IPC FOR LT ABC3X70+1X50+1X16 Tap 1.5 - 10 sq .mm
Anchoring /Dead end Clamp Assembly for LT AB Cables up to 70 sq.mm
Suspension Clamp Assembly for LT AB Cables up to 70 sq.mm
Stainless Steel Buckle Slot width 20.5 mm x 1.5 mm,Thickness 1.2 mm.
IPC for LT ABC 3X70 + 1X50 + 1X16 Tap 16-70 sqmm
Pre- Insulated Crimping Socket Palm Type 70 Sq.mm -Bimetallic (For ABC)
Pre- Insulated Crimping Socket Palm Type 16 Sq.mm -Bimetallic (For ABC)
Pre- Insulated Crimping Socket Palm Type 50 Sq.mm -Bimetallic (For ABC)
Earthing set (spiral)
G.I.WIRE. 4MM (8 SWG)
Anchoring /Dead end Clamp Assembly for LT AB Cables up to 50 sq.mm
Suspension Clamp Assembly for LT AB Cables up to 50 sq.mm
Stainless Steel Strap [20 mm x 0.7 mm]
Stainless steel Buckles [20.5 mm x 1.5 mm; thickness 1.2 mm]
Satellite connector â Main : 16 sq mm to 95 sq mm; Tap : 1.5 sq mm to 35 sq mm (4 way)
Earth Pit Chamber 18X18 cm PVC
Anchor / Dead End Clamp for AB Cables 70 sq.mm
Suspension Clamp for AB Cables 70 sq.mm
Insulation Piercing Satellite connector â Main : 16 sq mm to 95 sq mm; Tap : 4 sq mm to 35 sq mm (4 way)
Insulation Piercing Connector - Main: 16 sq mm to 95 sq mm; Tap : 16 sq mm to 95 sq mm
Labour
Additional rate for excavation of one Earth Pit (2.5m depth) in Laterite.
Installation of Pre-insulated straight through joints for 16sqmm cable
Dismantling (without damage) one km LT 3ph 4 wire OH line, cross arms, insulators and stacking the conductors in rolls.
Dismantling (without damage) one km LT additional conductor line, cross arms, insulators and stacking the conductors in rolls.
Stringing of 1.1 kV Aerial bunched cable of size 3 x 70 + 1 x 16+1x 50 sqmm with bare/insulated Messenger through existing poles
Erection of Anchor clamp / dead end clamp for LT ABC of any size
Erection of suspension clamp for LT ABC of any size
Installing One No. Insulation piercing connector of size Main :16 to 95 ,Tap:1.5 to 16 Sq.mm
Installation of Insulation piercing connector for main to service line main :16-95 sqmm, Tap : 4-35 sqmm
Installation of Pre-insulated straight through joints for 50sqmm cable
Installation of Pre-insulated straight through joints for 70sqmm cable
Installation of Pre-insulated lugs for 16sqmm
Installation of Pre-insulated lugs for 50sqmm
Installation of Pre-insulated lugs for 70sqmm
Fitting of one No. pole top service connection box of standard size (up to 4 way) using ss strap/B&N of suitable size in to the PSC/A poles at the standard height excluding giving connections
Providing End Caps
Installing One No. 4 way Satellite Connector of size Main :16 to 95, Tap:4 to 35 Sq.mm to the LT AB cable of Standard size
Providing Cable Tie
Providing one Earth using earth pipe incl. digging separate pit at standard distance away from the pole/structure & backfilling.
Dismantling and reconnecting Sph service connection from the OH line incl. lowering down the WP portion.
Dismantling and reconnecting 3ph service connection from the OH line incl. lowering down the WP portion.
Fitting one No. Section fuse on LT line with dropping cables, crimping sockets, connecting with bolt&nut etc.
Providing one Coil Earth using GI earth wire, digging separate pit at standard distance away from the pole/structure & backfilling.
Installation of Insulation piercing connector for main to service line main :25-95 sqmm, Tap : 25-95 sqmm
Dismantling (without damage) one km LT Sph 2 wire OH line, cross arms, insulators and stacking the conductors in rolls.
Transporting LT ABC by hired vehicle to a distance up to 5 km and carring up to 2 drum including loading and un loading using crane
Installation of Insulation piercing connector for main to service line main :16-95 sqmm, Tap 16-95 sqmm
JOS LUMINOUS PRIVATE LIMITED
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_859902.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .