Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 CrAccepted-AOC | ₹3.9 Cr | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹5.1 Cr+₹1.3 Cr (32.7%)Rejected-Finance SHREE KUNJ HOUSE NO 22B JIBAN KRISHNA PATH NEAR L P SCHOOL HENGRABARI GUWAHATI PIN 781036 | GUWAHATI | KAMRUP | ASSAM | 781036 | ₹5.1 Cr+₹1.3 Cr (32.7%) | L2 | Rejected-Finance Not being lowest |
Tender Value
₹3.5 Cr
EMD Value
₹4.3 L
Closing Date
14 Nov 2022, 6:00 pmClosed
CE SHILLONG ZONE
HQ CE SHILLONG ZONE, SPREAD EAGLE FALLS, SHILLONG, MEGHALAYA, 793011
PROVN OF GIRLS HOSTEL AND ALLIED INFRASTRUCTURE FOR GIRL CADETS IN SAINIK SCHOOL GOALPARA UNDER GE GUWAHATI
2022_MES_540326_2
CESZ/GUA/ OF 2022-23
Open Tender
Civil Works
Lump-sum
365 days
GOALPARA
All as per NIT
2 documents required · 2 mandatory
₹2,000
Yes
GE GUWAHATI
₹4.3 L
Yes
19 Jan 2023
19 Oct 2022
16 Nov 2022
19 Oct 2022
14 Nov 2022
2 Nov 2022
Amount
NOTE:- (Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
Lumpsum price workedout by the tenderer for 'BUILDING & STRUCTURES WORKS' as listed in Schedule ‘A’ Part-I
Lumpsum price worked out by the bidder/ tenderer for 'SITE CLEARANCE, SITE DEVELOPMENTS & EARTH WORKS' as listed in Schedule 'A' Part-II.
Lumpsum price worked out by the bidder/ tenderer for 'INTERNAL WATER SUPPLY' as listed in Schedule 'A' Part-III.
Lumpsum price worked out by the bidder/ tenderer for 'INTERNAL ELECTRIFICATION' as listed in Schedule 'A' Part-IV.
Lumpsum price worked out by the bidder/ tenderer for 'SUMMER APPLIANCES & HOT WATER SUPPLY' as listed in Schedule 'A' Part-V.
Lumpsum price worked out by the bidder/ tenderer for 'ROAD, PATH/HARD STANDING' as listed in Schedule 'A' Part-VI.
Lumpsum price worked out by the bidder/ tenderer for 'EXTERNAL WATER SUPPLY' as listed in Schedule 'A' Part-VII.
Lumpsum price worked out by the bidder/ tenderer for 'EXTERNAL ELECTRIFICATION' as listed in Schedule 'A' Part-VIII.
Lumpsum price worked out by the bidder/ tenderer for 'SEWAGE DISPOSAL' as listed in Schedule 'A' Part-IX.
Lumpsum price worked out by the bidder/ tenderer for 'AREA DRAINAGE' as listed in Schedule 'A' Part-X.
Sch 'A' Sec-XI (Miscellaneous Items) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
Supply and fix voltage stablizer for automatic operation ,single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output volatage stabilized at 230 v with accuracy of +/- 2.5% and of capacity 2.0 KVA complete all as specified and as directed.
Material & Labour for Wet mix macadam (WMM), 150 mm thick (compacted thickness) in two layers (75 mm thick each layer) compacted separately with coarse aggregates of grading as specified in SSR Part I clause No. 20.B.2.5.4 and spread rolled and consolidating to required gradient and camber as specified in sub para 20.B.5 of MES Schedule Part-I complete all as specified and directed.
Supply and fix 3 layered fusion welded PP-R (polypropylene Random Co -Polymer) gate valve of size 90 mm (brass insert as per requirement of the site with handle, screwed both ends for PP-R pipes or for unions fixed of grade SDR - 7.4 (PN-16) complete all as specified and directed.
Material & Labour for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm x 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M-15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M-15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke dust and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.
Material & Labour for earthing complete with copper earth plate 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 20 mm x 3 mm copper strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M-15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M-15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke dust and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.
Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5m below ground level connetced with galvanised wire of 4mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke dust and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed.
Supply & fix timer distribution board, 40 Amps, 230 volts, 3 pole digital time switch confirms to IEC 60439, rated upto 2500A, weatherproof enclosure CPRI tested complete all as specified and directed.
Supply, install, test and commission LT Panel board, TPN 415 Volts, 50 Hz, out door cubical type floor mounted CPRI approved factory made, double door dust and vermin proof IP-54, fabricated out of CRCA sheet not less than 3.15mm thick with 2mm thick for internal compartment duly powder coated fixed on angle iron pedestal made out of 50 x 50 x 6 mm with cable chamber for individual feeders for incomming and outgoing connections, one set of LED indicator lamp RYB with switch, fuse and the panel board shall be provided with proper ventillation including suitable size of cable alley TPN aluminium bus bar duly insulated insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulator suitable for carrying of current 630 Amps with suitable connections from MCCB out going to main bus bar shall be carried out. Including necessary PCC foundation and fixed with suitable nuts, bolts, washers etc. as per manufacturers instruction. Panel shall comprise following:
Sr. Item No. 11.08 (Contd/..) (a) Incoming (i) MCCB 400 Apms, 4 Pole, 50 Hz, 415 Volts with thermal magnetic release having rupturing capacity 36 KA- 01 No (b) Outgoing (i) MCCB 250 Apms, 4 Pole, 50 Hz, 415 Volts with thermal magnetic release having rupturing capacity 25 KA- 02 Nos (ii) 3 phase Digital multi function meter, model A, class 1, 5A with relay Vega series (iii) Phase indicator lamps (RYB) set of 3 - 01 Set Note : (a) Excavation and PCC foundation for LT Panel shall be deemed included in quated rate. (b) Extra space be left on panel's dinrail for mounting MCCB/ MCB and extra space cover with blank plate.
Supply, install, test and commission LT Panel board, TPN 415 Volts, 50 Hz, out door cubical type floor mounted CPRI approved factory made, double door dust and vermin proof IP-54, fabricated out of CRCA sheet not less than 3.15mm thick with 2mm thick for internal compartment duly powder coated fixed on angle iron pedestal made out of 50 x 50 x 6 mm with cable chamber for individual feeders for incomming and outgoing connections, one set of LED indicator lamp RYB with switch, fuse and the panel board shall be provided with proper ventillation including suitable size of cable alley TPN aluminium bus bar duly insulated insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulator suitable for carrying of current 630 Amps with suitable connections from MCCB out going to main bus bar shall be carried out. Including necessary PCC foundation and fixed with suitable nuts, bolts, washers etc. as per manufacturers instruction. Panel shall comprise following:
Sr. Item No. 11.09 (Contd/..) (a) Incoming (i) MCCB 200 Apms, 4 Pole, 50 Hz, 415 Volts with thermal magnetic release having rupturing capacity 36 KA- 01 No (b) Outgoing (i) MCCB 125 Apms, 4 Pole, 50 Hz, 415 Volts with thermal magnetic release having rupturing capacity 25 KA- 01 No (ii) MCCB 63 Apms, 4 Pole, 50 Hz, 415 Volts with thermal magnetic release having rupturing capacity 25 KA- 01 No (iii) MCB 63 Apms, 4 Pole, 50 Hz, 415 Volts with thermal magnetic release having rupturing capacity 16 KA- 01 No Note : (a) Excavation and PCC foundation for LT Panel shall be deemed included in quated rate. (b) Extra space be left on panel's dinrail for mounting MCCB/ MCB and extra space cover with blank plate.
Material & Labour for RCC septic tank conventional type for 150 users design to carry sewage and sludge water constructed with RCC M-30 (Design Mix) including excavation in any type of soil earthwork, returning, filling in and removal of soil upto not exceeding 50m and as shown in TD drawing No. CESZ/2020/STD-02 sheet 1/2 & 2/2 and as specified and directed.
Material & Labour for soakage well of size 3 m dia and 3 m effective depth including intercepting chamber and screen chamber, including excavation in any type of soil earthwork, returning, filling in and removal of soil upto not exceeding 50m and as shown in TD drawing No. CESZ/2020/TD-45, sheet 1/2 & 2/2 complete all as specified and directed.
Supplying and laying of 40 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors/trenches including special fittings like CPVC Brass fittings (Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor) complete all as specified and directed.
Supplying and laying of 32 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors/trenches including special fittings like CPVC Brass fittings (Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor) complete all as specified and directed.
Supplying and laying of 20 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors/trenches including special fittings like CPVC Brass fittings (Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor) complete all as specified and directed.
Supply and fix concealed type Point wiring with 1.5 Sq. mm (nominal cross sectional area) PVC insulated and un-sheathed single core FRLSH copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC rigid concealed conduit and conduit accessories alongwith continuous earth wire 1.5 Sq mm PVC insulated and un-sheathed single core FRLSH cable 1100 volts grade with multi-stranded copper conductor and connected to common earth dolly, with and including 1.6 mm thick cadmium plated sunk MS pressed steel terminal boxes with 3 mm thick plastic laminated sheet cover fixed with brass screws complete for one light/fan/bell point controlled by one way switch.
Supply and fix concealed type Point wiring with 1.5 Sq. mm (nominal cross sectional area) PVC insulated and un-sheathed single core FRLSH copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC rigid concealed conduit and conduit accessories alongwith continuous earth wire 1.5 Sq mm PVC insulated and un-sheathed single core FRLSH cable 1100 volts grade with multi-stranded copper conductor and connected to common earth dolly, with and including 1.6 mm thick cadmium plated sunk MS pressed steel terminal boxes with 3 mm thick plastic laminated sheet cover fixed with brass screws complete for one socket outlet point 6 Amp on same board.
Supply and fix concealed type Point wiring with 1.5 Sq. mm (nominal cross sectional area) PVC insulated and un-sheathed single core FRLSH copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC rigid concealed conduit and conduit accessories alongwith continuous earth wire 1.5 Sq mm PVC insulated and un-sheathed single core FRLSH cable 1100 volts grade with multi-stranded copper conductor and connected to common earth dolly, with and including 1.6 mm thick cadmium plated sunk MS pressed steel terminal boxes with 3 mm thick plastic laminated sheet cover fixed with brass screws complete for one socket outlet point 6 Amp on independent board.
Supply and fix concealed type Point wiring with 1.5 Sq. mm (nominal cross sectional area) PVC insulated and un-sheathed single core FRLSH copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC rigid concealed conduit and conduit accessories alongwith continuous earth wire 1.5 Sq mm PVC insulated and un-sheathed single core FRLSH cable 1100 volts grade with multi-stranded copper conductor and connected to common earth dolly, with and including 1.6 mm thick cadmium plated sunk MS pressed steel terminal boxes with 3 mm thick plastic laminated sheet cover fixed with brass screws complete for one light point controlled by two way switch.
Supply and fix concealed type Point wiring with 4 Sq. mm (nominal area) PVC insulated and un-sheathed single core FRLSH copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC rigid concealed conduit and conduit accessories alongwith continuous earth wire 4 Sq mm PVC insulated and un-sheathed single core FRLSH cable 1100 volts grade with multi-stranded copper conductor and connected to common earth dolly, with and including 1.6 mm thick cadmium plated sunk MS pressed steel terminal boxes with 3 mm thick plastic laminated sheet cover fixed with brass screws complete for one16 Amps socket outlet on independent board.
Sub main wiring with two runs of single core FRLSH PVC insulated and unsheathed multistranded, copper conductor cable of size 6.0 Sq mm (nominal area), 1100 volts grade drawn through and including adequate size PVC concealed conduit and accessories (IS-694 marked in PVC conduit) and fittings and one run of 6.0 Sq mm single core FRLSH multistranded copper conductor cable as earth continuity conductor. NOTES :- (a) Two runs of copper conductor, one run of earth wire and one run of conduit shall be measured as one run length.
Supply and fix MCB Triple Pole and Neutral 415 volts, 63 Amps, 10KA rupturing capacity, 'C' series complete all as specified.
Supply and fix MCB Triple Pole and Neutral, 415 volts, 32 Amps, 10KA rupturing capacity, 'C' series complete all as specified.
Supply and fix MCB double Pole/SPN, 415 volts, 32 Amps, 10KA rupturing capacity, 'C' series complete all as specified.
Supply and fix MCB Single Pole 415 volts, 6Amps to 32 Amps, 10KA rupturing capacity, 'C' series complete all as specified.
Material & Labour for Liquid seal coat, applying evenly binder of paving bitumen of grade of VG-30 @ 9.8 kg per 10 sqm blinding with 6.3mm size stone chippings @ 0.09 cum per l0 sqm and rolled to a uniform smooth surface complete all as specified and directed
Supply & fix cromium plated health faucet suitable for 20 mm outer dia of CPVC pipe with 1.25m long flexible tube and wall hook including making connections complete all as specified and directed.
Supply & fix cromium plated toilet paper holder with cover complete all as specified and directed.
Supply & fix cromium plated fancy type peg set fixed with PVC rawl plug and steel screws on walls complete all as specified and directed.
M/S PRASANTA MAHANTA
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .