| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.2 CrAccepted-AOC KOTHI NO 901 2ND FLOOR PHASE 3B 2 SAS NAGAR MOHALI PB 160059 | MOHALI | SAS NAGAR | PUNJAB | 160059 | ₹4.2 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹4.7 Cr+₹45.1 L (10.7%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹4.7 Cr+₹45.1 L (10.7%) | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹4.7 Cr+₹51.4 L (12.2%)Rejected-Finance | ₹4.7 Cr+₹51.4 L (12.2%) | L3 | Rejected-Finance NOT LOWEST |
| 4 | L4₹4.9 Cr+₹65.0 L (15.4%)Rejected-Finance 00 00 NAPASAR ROAD NENO KA BASS BIKANER RAJASTHAN BIKANER RAJASTHAN 334022 UDYAM RJ 08 0001676 | BIKANER | RAJASTHAN | 334022 | ₹4.9 Cr+₹65.0 L (15.4%) | L4 | Rejected-Finance NOT LOWEST |
| 5 | L5₹4.9 Cr+₹67.3 L (15.9%)Rejected-Finance | ₹4.9 Cr+₹67.3 L (15.9%) | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹6.2 Cr
EMD Value
₹6.4 L
Closing Date
12 Jun 2023, 6:00 pmClosed
CE (AF) WAC PALAM
HQ CE (AF) WAC PALAM
PROVN OF CERTAIN MISC WORK AT AF STN CHANDIGARH (PH-I)
2023_MES_580999_1
CEWAC/CHD/T-26/2022-23
Open Tender
Civil Works
Item Rate
365 days
GE (AF) CHANDIGARH
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
GE (AF) CHANDIGARH
₹6.4 L
Yes
14 Aug 2023
21 Feb 2023
14 Jun 2023
21 Feb 2023
12 Jun 2023
22 May 2023
Amount
B/R PORTION
Taking down cement plaster, on brick walls.ceilings and concrete surfaces and the like, any description including raking out joints, hacking for key, scrubbing down with water, etc. and removal of rubbish outside MOD land, complete all as specified and as directed.
M&L for rendering 15mm thick plaster in cement mortar (1:4), on brick/concrete surfaces of walls, finished even and fair using waterproofing compound @ 3% of cement weight, complete all as specified and as directed. Note :- WPC shall be measured and paid separately under respective items.
M&L for rendering 10mm thick plaster in cement mortar (1:3),on concrete surfaces of ceiling, finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15mm thick plaster in cement mortar (1:6), on concrete surfaces of wall, finished aven and smooth without using extra cement, complete all as specified and as directed.
Supply only integral water proofing compound.
M&L for preparation of newly plastered surfaces of walls and applying three coat of white wash complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of ceiling and applying three coat of white wash complete all as specified and as directed.
Preparation of new plasler/ unplaster surfaces of wall and Material & Labour for applying two coats (in camouflage pattern as approved by GE)of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004. Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 lltre / 10 sqm over new surfaces complete all as specified and as directed.
Material & Labour for complete removal to existing treatment old surfaces on walls applying Two or more coats of Premium actylic emulsion paint having VOC less than 50 gm/lit and UV resistance as per IS 15489:2004, Alkali & fungal resistance dirt resistance exterior paint of required shade (Camouflage pattern) with silicon additives @ 1.43litr / 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre / 10 sqm complete all as specified and as directed.
Dismantling Brick tiles or terracing tiles, single layer on roofs pointed in cement mortar, and removing unservicing tiles out side MOD as sch of credit complete all as specified and as directed.
Demolition of mud phuska in roofs any thickness including plastering and leeping removing out side MOD land, complete all as specified and as directed.
M&L for 40mm thick brick tiles laid on mud mortar and joints grouted flush in cement mortar 1:3 ) mixed with 5% of crude oil by weight of cement on cement mortar screed bedding in CM (1:6), complete all as specified and as directed
Taking down existing bitumen felt roof treatment including cement mortar bedding and cleaning the surface, and removal out side the MOD land complete all as specified and as directed
S & F Plain, galvanised, mild steel sheeting,1 mm thick in ridges, hips, valley gutters, drip and straight flashings crumple joints in roofs (length and girth as flxed) complete all as specified and as directed.
M&L for plain cement concrete (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregates) as in coping, roof pading, roof kerb or mud stops, water through, benching and like including weathering slightly, rounded or chamfered angle and throating with necessary form work complete all as specified and as directed
M&L for 10mm thick cement plaster in cement mortar (1:4) mixed with WPC as per manufacturer's instruction @ 3% by weight of of cement on concrete surfaces finished even and smooth without using extra cement, after applying neat cement slurry @ 3Kg/Sqm, including wire brushing sweeping, cleaning, washing down to remove all loose dust etc. and preparing roof surfaces, complete all as specified and as directed. Note:- WPC will be measured and paid separately.
M&L for water proofing treatment of roof consisting as under:- (a) Applying a coat of bituminous primer conforming to IS-3384:1986 @ 0.30 Ltr/ Sqm including preparation of roof surfaces. (b) A layer of 3mm thick APP polymer mambrane of weight not less than 3.0Kg/ Sqm, reinforced with polyster non wove fabric (wt. not less than 150 Gms/Sqm) duly sealed at over laps and joint with flame (by torch aplicalion) all as per manufacturer's complete all as specified and as directed.
Dismantling floor, hearth or wall tiling Including cement mortar bedding but not hacking, removal serviceable tiles to store and rubbish off the pennises complete all as specified and as directed
Material and labour for non-skid coloured ceramic tiles 7mm to 8mm thick (square/rectangular) area of each tile exceeding 0.11sqm but not exceeding 0.16sqm,in floors etc, set jointed in neat grey cement slurry @ 3Kg/Sqm and pointed in white or coloured cement to match, laid over and including 15mm thick screed bed in CM (1:4), complete all as specified and as directed.
S&F first quality glazed designer pattern coloured ceramic tiles of size 450mmx300mmx7mm thick fixed in pattern to wall (combination of dark & light colour with border) as in skirting, dado, set and jointed in neat cement slurry, over and including 10 mm thick randering of cement mortar (1:3), including pointing in white cement with pigment to match the shade of tiles complete all as specified and as directed
Supplied & fixing, 4 mm thick figured glass pin head type, squares / rectangulars n.exc 0.5 Sq.m each pane complete all as specified and as directed.
Supply and fix in repairs PVC polypropylene, valve less syphonic action type flushing cistem 10 litre capacity, low level, white/coloured with inlet, ball valve with float and handle, including new brackets fixed in position, PVC bend/flush pipe 32mm dia, complete including connections to water mains & taking down and removal of old hig / low level flushing cistern complete all as specified and as directed.
Supply and fixed in repair, vitreous china oounter top (self rimming) wash hand basin, white in colour of size 630mm x 500mm including circular cutting and tucked in granite slab inclduing 15mm dia cast copper alloy chromium plated fancy type single lever basin mixer, 32mm dia brass cp waste fitting and connection to waste pipe and water pipe complete all as specified and as directed.
M&L 18 to 20 mm thick Granite (of any type) tiles machine cut , beding on 15 mm thick screed bed in cement mortar 1:4 and jointed, with grey cement slurrry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and as directed.
Cutting holes n. exc 150 Sq . Cm into or through brick walls built in cement mortar complete all as specified and as directed.
Brickwork with subclass 'B' bricks, straight or curved on plan to any radius in helf brick thick walls built in cement mortar 1:4 complete all as specified and as directed.
M&L for reinforcement cement concrete type B0 using 12.5mm gradded stone aggregate as in slabs supported on wall beams and columns in floors, roofs, landing, balconies, canopies, deck slabs and in shelves etc complete all as specified and as directed.
S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Supply and fixed in repair, vitreous china half stall type white including providing fixing plugs, bedding urinals against wall in cement mortar 1:2, securing urinal to plug with and including 60 mm long brass screws, pointing arround urinal back including waste coupling PTMT half or full threaded suitable for urinals complete all as specified and as directed.
S & F in repair 15 mm CP stop valve fancy type with long shank and cup (concealled type) screwed down high pressure, screwed both ends for iron pipe or unions complete all as specified and as directed
Supply and fix, in repair vitreous chinaware wash down water closet squatt pan (Orissa pattern/Indian type) of size 580mmx440mm, white, with integral foot rests (excluding flushing cistern and flush pipe but including Cl 'P' / 'S' trap), set and jointed including embedding concrete, and taking down old and removal complete all as specified and as directed.
Supply and fix in repairs bib taps, cast copper alloy, fancy type with capstan head, chromium plated, screwed down high pressure, screwed for iron pipe or for brass ferrule 15mm dia bore, complete all as specified and as directed.
Taking up or down steel tubing and connections. size 15mm dia bore, including cleaning for re-fixing or removal to stores, complete all as specified and as directed
S&F 15mm bore galvanised iron tube medium grade with all fittings and fixed, complete all as specified and as directed
Taking up or clown steel tubing and connections, size 20mm dia bore, including cleaning for re-fixing or removal to stores, complete all as specified and as directed
S&F 20mm bore galvanised iron tube medium grade with all fittings and fixed, complete all as specified and as directed
Supply and fix, 100mm dia bore cast iron branch pieces, single (equal or un equal). ordinary or inverted (spigot or socketed) or with parallel branches, as in repairs complete all as specified and as directed.
Material and labour, cast iron floor trap, 75mm dia of out let, ISI marked, with mild steel cromium plated grating, including jointing to waste pipe in plain cement concrete (1:2:4) type B-1, as in repairs, complete all as specified and as directed.
Supply and fixed in repairs angle stop valves, cast copper alloy, screwed down high pressure, fancy type with capstan head, chromium plated, screwed both ends for iron pipe or for unions, or for brass ferrule 15mm dia bore, as in repair complete all as specified and as directed.
Dismantling water tanks(PVC), capacity exc 500ltr but n. exc 1000 ltr and removing, complete all as specified and as directed
Hoisted and fixed in position rotational moulded polyethelene triple layer, water storage tanks (cylindrical vertical with closed top) white in colour of capacity 1000 ltr including inlet pipe and plug, outlet, waste etc incuding 20mm dia ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 200 m m - 210 gms ) all as specified in SSR Part I, complete all as specified and as directed.
Supply & Fixed in repairs PVC connection 15 mm size with PTMT nuts of length 450mm, complete all as specified and as directed.
Dismantling of old Cl pipes of any type and any dia. complete all as specified and as directed
S&F 100 mm bore cast iron spun pipes soil waste and vent pipes, in any length with or without ears with cement joints, laid in trenches or floors/walls, complete all as specified and as directed.
S&F 75 mm bore cast iron spun soil,waste and vent pipes, in any length with or without ears with cement joints, laid in trenches or floors/walls, complete all as specified and as directed.
S&F in repair 20mm dia gun-metal globe or gate valves, with iron wheel head screwed both ends for iron pipe. complete all as specified and as directed.
S&F in repair 75mm Cl branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and as directed
Taking down chowkhats or frames (any type) n.exc 1.5 Sqm each without taking off shutters from frame and removing from site, complete all as specified and as directed.
Taking down chowkhats or frames (any type) exc 1.5 Sqm but n.exc 4.0 Sqm each without taking off shutters from frame and removing from site, complete all as specified and as directed.
Material and labour, cutting holes in brick walls built in cement mortar for inserting hold fasts, depth of embedded portion of hold fasts or lugs measured from the face of the jamb into the wall exceeding half brick but n. exc one brick thick wall, complete all as specified and as directed.
Supply and fixing, factory made pressed steel frames for doors with two rebates, of size 125mmx60mm, made out of 1.25mm thick sheet, including necessary fixing lugs, hinges, lock strike plate, etc.including holdfast, complete all as specified and as directed.
S&F Factory Made Solid PVC Moulded Door Shutters 28 to 30 mm thick (stiles), with 2,4 or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front Face & on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and as directed
Supply and faxing, Solid PVC door frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with M.S. square tube, as per specification & drawing in SSR Part-II, in opening complete all as specified and as directed
S&F steel window with side hung shutters including projecting type hinges with steel handle and steel peg stay, complete with glazing bars dovetailed or welded. complete all as specified and as directed.
S&F steel window with side hung shutters including projecting type hinges with steel handle and steel peg stay, complete but without glazing bars dovetailed or welded complete all as specified and as directed.
S & F Steel ventilators with top hang shutter including hinges, steel peg stay, complete all as specified and as directed
S&F sheet glass 4 mm thick, ordinary quality and glazing with oil putty or wooden beads in square n exc 0.5 sq. m in each pane, including one coat of synthetic enamel paint match to existing surfaces, complete all as specified and as directed.
S&F stainless, steel wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples or fixed to wooden bead, complete all as specified and as directed.
Plain mild steel wire galvanised 4mm dia class 3 in fencing including straining and fixing to wood, concrete or steel posts and/or to straining bolts, including securing with and provision of galvanised iron tying wire, galvanised iron staples or steel pins, etc. as directed (each line of wire to be measured) complete all as specified and as directed
S & F for hand rails half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing botts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, batting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed
Cutting holes exc 100 sqcm but n.exc 250Sqcm into or through cement concrete slabs, chajjas, walls etc complete all as specified and as directed
S & F 100mm butt hinges, extruded aiuminium alioy with galvanised mild- steel hinge pin, anodised, type C-21, complete all as specified and as directed
S&F 200 mm aluminium anodised, barrel tower bolls of extruded section, complete all as specified and as directed.
S&F 250mm long aluminium alloy, anodised.sliding.door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded, sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and ftxed, complete all as specified and as directed
S&F for 150mm aluminium handles, cast type, anodised complete all as specified and as directed
Preparation of new steel surfaces and applying two coat of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as directed
Demolition of cement concrete (un-reinforced ) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed
M&L for plain cement concrete (1:3:6) type C-2 (using 40mm graded crushed stone aggregates) as in surface channels and drains, complete all as specified and as directed
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc, complete all as specified and as directed.
Demolition of stone or brick masonry built in cement mortar including all quoins, arches etc. (other than roofs, floor / paving) and removing demolished material out side of MoD land, complete all as specified and as directed.
M & L for brick work with old size sub class ‘B’ bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and as directed.
M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces of walls, finished even and smooth without using extra cement , complete all as specified and as directed.
M&L for PCC 1:2:4, type B-1, using 20mm graded stone aggregates as in lintel upto 1.5 mtr span cill steps seismic and other similar band plinth course lacing course parapet and railing coping ,bed plate etc including weathering slightly rounded or chamfered angles and throating complete all as specified and as directed
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for (below or above ground level), complete all as specified and as directed. Note :- Demolition shall also cater for sharp cutting of the purposed panel of demolition at joints with the existing adjacent concrete slab with diamond cutter upto full depth.
M&L for removing demolished materials etc retrieved from item no 1.75 above to a distance exc 1.50km to 5.00km from the starting point to out side of MOD land complete all as specified and as directed (One load = 0.62 Cum)
M&L for providing and laying dry lean concrete (DLC) 150mm thick of aggregate gradation as per table 1 of SP 49:2014 having 7 days average compressive strength not less than 10Mpa. Minimum cement content not less than 240 Kg/cum DLC mixed in Batching Plant, transported to site and laid by electronic sensor paver including spreading and compacting using high amplitude tamping bars of paver (initial compaction) further by double drum smooth wheeled vibratory rollers with 80-100 KN static weight to achieve minimum dry density not less than 98% of the maxmimum dry density, necessary finishing etc, complete all as specified and tolerances as per Table 900-1 of MoRTH specifications for road and bridge works, 2013.
M&L for supplying and laying 400 micron thick HDPE sheet (virgin quality) water proof, wrinkle free without puncture having minimum weight 390 gm/sqm over tack coat/sand cushion as specified in the design with overlap between adjacent strips and at traverse joints as minimum 300 mm complete all as specified.
Supply only non circular synthetic Polyester fibers complete all as specified and directed Note : (a) Specifications for Fibers shall be as per appx to E-in-C's Branch letter no.95610/Policy/Mon/E2W (RI-1) dated 26 Oct 2020
M&L for 250mm thick PQC work in pavement of flexural strength of 45 kg/sqcm in field using minimum cement content 425 kg of cement per cubic meter, including necessary form work bullnoislng rounding off edges finishing by mechanical, complete all as specified and as directed. Note :- The minimum cement content shall be 425 kg for design mix, if during design mix cement decreases then minus DO shall be initiated and if cement content increases nothing shall be paid extra.
M&L finishing surface of concrete roads pavements by brooming, complete all as specified and as directed.
M&L for forming Dummy/ Contraction joints with an initial saw cut of 3 mm soon after the concrete has set, upto a depth of 1/3rd to 1/4th the thickness of the slab widening the first saw cut to 6 mm and 24 mm deep by using diamond bit cutter of appropriate size straight and smooth edges. Joint cleaned throughly with application of compressed air. Joint shall be made dry, vacuum cleaned and free of dirt, oil vegation and other debris. Application of two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before placing the backup rod and pouring the sealant. Placing of closed cell, medium density, crossed linked polyethylene foam backup rod of 8 mm dia application of bond breaker tape on top of back up rod for complete width of the joint and top 12mm filled with polyurethane based sealant complying with BS-5212, BS 4254 and EN-141875-2003 with minimum movement accommodation factor (MAF) of +/- 30% having minimum 10 year performance guarantee applying masked tape on the edges of joints and removing the masking tape after filling of sealant as per the method specified by the manufacturer complete all as specified and as directed
M&L for forming 25mm width expansion joints in concrete slab for full depth of PQC. Early entry saw and subsequent cutting by using diamond bit cutter of appropriate size, straight and smooth edges. Joint cleaned thoroughly with application of compressed air. Joint shall be made dry, vacuum cleaned and free of dirt, oil, vegetation and other debris. The joint then filled with pre-moled 25mm thick compressible polythylene closed cell type filler board as specified thereafter application of two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before placing the sealant. Placing of closed cell medium density, crossed linked polyethylene foam backup rod of 30 mm dia, over filler board and top 20mm filed with polyurethane based sealant complying with BS-5212, BS 4254 and EN-141875-2003 with minimum movement accommodation factor (MAF) of +/- 30% having minimum 10 year performance guaranteee aplying masked tape on the edges of joints and removing the masking tape after filling of sealant as per the method specified by the manufacture complete all as specified and directed.
Providing and applying water borne paint (WBR) having DFT 240 micron thick road marking strips(retroreflective) of specified shade/ colour using by fully/semi automatic paint applicator machine (using cold airless spray/striper machine with minimum two spray gun) including application of Drop-on glass beads driven by experienced operator on road surface including cost of material, labour, T&P. cleaning the road surface of all dirt. seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications on bituminus surface / concrete by using air less spreay machine colour of paint shall be white / yellow / black / red or any colour required at site by user on Taxiway / Dispersal marking exceeding 10 cm width or girth as per recommended dimentions and as directed by Engineer In Charge.The existing surfaces shell be cleaned throughly with broom off dirt, dust, scales, oil greases etc. before application of the paint specification of the machine is as under :- Graco line lazer 3900 with 2 guns and the maximum GPM (LPM): 1.60(6.0), PSI (Bar) :3300(227), Engine cc (hp) :120cc and maximum tip size :0.029 specification as per diected by Engr-ln-Charge. Note :- Ser No 1 to 5:- (a)Work will be carried out by the applicator of Manufacturers representative of company approved by GE.
M&L for racking out of old existing sealant compound and back up rod of the existing joints by special tools like cutting blades/ machines, widening of joints by 2mm by using joint cutting blades of appropirate size, straight and smooth edges. Joint cleaned throughly with application of compressed air. Joint shall be made dry, vacuum cleaned and free of dirt, oil, veetation and other debris. Application of two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before placing the backup rod and pouring the sealant. Thereafter filled with closed cell medium density, cross linked polythylene foam backup rod of 8 mm dia for complete length of the joint, over it to be filled top 12mm with polyurethane joint sealant meeting the requirements mentioned in BS-5212, BS 4254 and EN-141875-2003 with minimum movement accommodation factor (MAF) of +/- 30% complete all as specified and as directed.
M&L for racking out of old existing sealant compound, back up rod and filler board of the exisitng joints by special tools like cutting blades/ machines, widening of joints by 2mm by using joint cutting blades of appropirate size, straight and smooth edges. Joint cleaned throughly with application of compressed air. Joint shall be made dry, vacuum cleaned and free of dirt, oil, vegetation and other debris. Application of two coats of primer with thin brush by forward and backward movement at an interval of 30 minutes before placing the filler board and pouring the sealant. Thereafter filled with pre-molded 25mm thick compressible polythylene closed cell type filler board as specified, over it filled with closed cell medium density, cross linked polyethylene foam backup rod of 30 mm dia for complete length of the joint,. Finally filled top 20mm with polyurethane joint sealant meeting the requirements mentioned in BS-5212, BS 4254 and EN-141875-2003 with minimum movement accommodation factor (MAF) of +/- 30% complete all as specified and as directed.
Rolling and consolidating forming surface with 8 to 10 tonne power roller including fillings in soft sports, depressions etc which occur during rolling (for portion coming in cutting/orginal ground only) to required camber and gradient etc, Including watering before or during rolling complete all as specified and as directed
M&L for laying and compacting 150 mm thick(compacted thickness) Granular sub base course (GSB) grading as per Grade V as specified Table 900-1 of MaRTH specifications for Raod and Bridge works, 2013, in a single layer over compacted subgrade with natural sand, curshed gravel, crushed stone, crushed slag or combination thereof as per the gradign required. The materials are mechanically mixed, spread and leveling on the subgrade by using motor grader of adequate capacity, and roling with vibratory roller and capacity 80-100 KN satic weight for achieving required compaction density of atleast 98% of the MDD to achieve 'K' value of min 4 Kg/sqcm/cm consolidating to required gradient and camber complete all as specified and directed with finished surface tolerances as per Table 900-1 of MaRTH specifications for road and bridge works, 2013 complete all as specified and as directed
M&L for forming 12mm thick expension joints filled with pre formed bituminous fillers and top 30mm primed and sealed with sealing compound grade 'A' of 100mm thickness of slab/floor, complete all as specified and as directed.
M&L for forming contraction dummy joints 65mm deep x 10mm wide filled with sealing compound of grade 'A', complete all as specified and as directed.
M&L for stabilising subgrade upto depth of 500mm using cement at the rate of 3% of treated subgrade soil to achieve minimum 'K' value of 3kg/sqcm/cm including rolling and consolidation of subgrade not exc 15cm depth in each layer using power roller/ compactor exc 8 ton and n.exc 15 ton earth under OMC to achieve the minimum 98% density MOD using Modified compactor density determination method as per IS code complete all as specified and as directed.
M&L for hardcore of gauge n. exc. 63mm of broken ston, deposited,spread and levelled in layers not evceeding 15 cm thick, water and rammed to a true surfaces, complete all as specified and as directed.
M&L for 75 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base concrete, complete all as specified and as directed.
M&L for machine pressed precast concrete interlocking paver block of any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade with grey cement and no pigment, complete all as specified and directed.
M&L for providing cement concrete type C-1 1:3:6 (20 mm graded stone aggregate) in roof kerb or mud slops rounded or chamfered on edges, complete all as specified and as directed.
E/M PORTION
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
Taking down carefully submain wiring of any size including service connection complete with PVC conduit and GI wire any size and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
M&L for point wiring complete with 1100 volts grade PVC insulated unsheathed FRLS cable of copper conductor multi stranded of size 1.5 sqmm, single core drawn through and including stove enamelled steel conduit surface type of size 20 mm dia or higher, including tee, junction, bend etc. and drawing continous earth wire of FRLS PVC insulated (green insulation) copper conductor of size 1.5sqmm and connected to common earth dolly for one light / fan point controlled by one, one way switch complete all as specified and as directed.
All as per item No - 2.03 above but with 2.5 Sqmm cable insulated for 3 pin 15mm multipurpose outlet including 2.5 sqmm PVC insulated copper wire for earth continuty on independent board complete all as specified and as directed.
M&L for point wiring complete with 1100 volts grade insulated unsheathed FRLS cable of copper conductor multi stranded of size 1.5 sqmm, single core drawn through and including PVC conduit of size 25 mm dia or higher, including tee, junction, bend etc. concealed in wall, ceiling, floor etc, incl MS modular box of suitable size for housing modular switches, sockets and regulator etc and drawing continous earth wire of FRLS PVC insulated (green insulation) copper conductor of size 1.5sqmm and connected to common earth dolly all as specified for one light / fan point controlled by one, one way switch. Note :- The Cost of cutting, chasing and making good to existing surfaces are deemed to be included in the Quoted Rate.
All as per item No - 2.05 above but for one 5 amp socket outlet multipurpose on independent board complete all as specified and as directed.
All as per item No - 2.05 above but with 2.5 Sqmm cable insulated for 3 pin 15mm multipurpose outlet including 2.5 sqmm PVC insulated copper wire for earth continuty on independent board complete all as specified and as directed.
S&F switch piano flush button type, single pole, one way 6 Amps, complete all as specified and as directed.
S&F socket outlet flush type, 2/3 pins 6 Amps, multipurpose complete all as specified and as directed.
S&F switch piano flush button type, single pole, one way 16 Amps, complete all as specified and as directed.
S&F of socket outlet flush type, 3 pins 6 & 16 Amps, 230 volts, multipurpose complete all as specified and as directed.
S&F flame proof switch socket and plug combined in LM6 cable termination box in LM6, 16 Amps 250 Volts 2P + earth complete all as specified and as directed.
S&F flame proof switch rotary type with termination box in LM6 16 Amps single pole 250 Volts complete all as specified and as directed.
S&F LED lights fitting 1x9W, bulk head luminairs including LED light with driver connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F LED light fitting 1x18 W, 220V, AC decorative box type with driver holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rosecomplete all as specified and as directed.
S & F lamp holder, PVC / Polycarbonate type with back plate suitable for batton fitting complete all as specified and as directed
S&F ceiling fan complete with blades, down rods, electric regulator and accessories 230V, 1200mm sweep, Min air delivery 210 CFM with service value 6.0 BEE 5 star rated with brushless direct current motor (BLDC) including three core flexible copper conductor cable PVC insulated & overall sheathed of size 0.50 Sqmm of required length from ceiling rose to connector of ceiling fan complete all as specified and as directed
S&F exhaust fan made of sturdy Engineering Metal complete with louvers, shutter voltage 230V, 50 Hz, 1200 RPM, copper winding of sweep 380 mm complete with, bolt, nuts and washers, and provisioning of flexible copper cord three core PVC insulated & overall sheathed of size 0.50 sqmm from ceiling rose to exhaust fan complete all as specified and as directed.
S&F air circulator fan made of sturdy Engineering Metal voltage 230V, single phase oscillating 600mm sweep complete with, bolt, nuts and washers, and provisioning of flexible copper cord three core PVC insulated & overall sheathed of size 0.50 sqmm suitable for wall mounting complete all as specified and as directed.
S & F ceiling rose Surface bakelite 65x50 mm, two to three terminal 230 Volt complete all as specified and directed
Taking down old unserviceable SV/MH light fitting /TL light and removing from site
Supply and fix LED street light luminaries 150 watts made of pressure die cast aluminium housing with toughened glass and high power LED and secondary lensess with IP 66 protection complete with GI medium grade pipe bracket 40mm dia with FI clamps nut bolt and washer including connecting lead of 3 core 1.5 Sqmm flexible copper wire from junction box to fitting complete all as specified and as directed.
Supply and fix LED flood light luminaries 200 watts made of pressure die cast aluminium housing with toughened glass and high power LED and secondary lensess with IP 66 protection complete all as specified and as directed.
Supply and fix LED light fitting 150 watts, high efficiency round high bay in pressure die cast aluminium housing with toughened glass suitable for industral application 110 Lm/W to reduce quantity wattage with IP 66 protection and with additional chain complete all as specified and as directed.
Supply and fixing LED light fitting 2x16 watts, flame proof ,CMRI certified recommended for gas/vapour group of II A/ III B, Zone 1&2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass with LED tube light fixture driver, holders, connectors etc. complete with all accessories prewired and incl connecting up with three core flexible copper conductor cable complete all as specified and as directed
Supply and fixing LED flame proof well glass light fitting 60 watts, flame proof ,CIMFR certified recommended for gas/vapour group of II A/ III B, Zone 1&2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass complete with all accessories prewired and incl connecting up with three core flexible copper conductor cable complete all as specified and as directed
S&F wiring for circuit/submain wiring along with earth wire with two single core 2x 2.5 Sqmm (nominal area) PVC insulated and unsheathed cables with stranded copper FRLS conductor in and including steel conduit 25 mm dia or higher, ISI marked including one run of continuous PVC insulated FRLS multi stranded copper cable of size 1x2.5 Sqmm earth wire for earth continuity conductor complete all as specified and as directed
S&F wiring for circuit/submain wiring along with earth wire with two single core 2x 2.5 Sqmm (nominal area) PVC insulated and unsheathed cables with stranded copper FRLS conductor in and including PVC concealed conduit 25 mm dia or higher, ISI marked including one run of continuous PVC insulated FRLS multi stranded copper cable of size 1x2.5 Sqmm earth wire for earth continuity conductor complete all as specified and as directed Note :- The Cost of cutting, chasing and making good to existing surfaces are deemed to be included in the Quoted Rate.
Supply and fixing, in replacement of DB sheet metal enclosure double door for MCBs, company made, SPN 240 Volts 8 ways with IP 42 protection complete all as specified and as directed
Supply and fixing, in replacement of DB sheet metal enclosure double door for MCBs, company made, SPN 240 Volts 4 ways with IP 42 protection complete all as specified and as directed
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB complete all as specified and as directed.
Supply and fixing amp rating 240V, 10 KA 'C' curve miniature circuit breaker (MCB) and current carrying capacity in the MCB DB SPN 42 to 63 AMP, complete with connection and testing, complete all as specified and as directed.
Material & labour in replacement of earthing complete with galvanize steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 meter below ground level with top edge of the plate not less than 1.5 metre below normal ground level, earth plate surrounded by 15 cm thick and packed alternate layers of charcoal dust and common salt, earth lead wire 4.0 mm dia by means of bolls, nuts , check nuts and washers of galvanized iron or steel and thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron or steel pipe medium grade 15 mm bore and water pipe 20 mm bore GI light grade (ISI marked ) with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and 50 mm thick RCC 1:2:4 type B-1 cover slab of earth pit reinforced with 8 mm dia TMT bars @ 10 cm C/C both ways and with handle made out of 8mm dia bar and all as shown in electrical plate No 5 of MES Sch Part-1 (2009), complete all as specified. Note – Old earthing may have been buried deeper than 2.25 mtr below ground level. Cost for excavation beyond 2.25 mtr deep to retrieve the old earthing, if done by contractor , shall not be made.
S & F rigid non-metallic, PVC conduit 32mm dia exclusive of boxes (junction / terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and as directed
M&L Air termination, single pointed aluminium rod 12 mm dia and 300mm long, complete all as specified and as directed
M&L for earth continuity conductor or main earthing lead of size 32x 6mm made of galvanised iron strip to be fixed on and including PCC 1:2:4 block of size 30 cm x 30 cm x 30 cm with the help of epoxy/porcelain insulators fixed/grouted in PCC block with the inter distance of blocks not more than 3 mtr complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of the earth plate not less than 1.5 m below ground level surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to Gl earth strip 32x6mm by means of bolts, nuts,check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part- 1, connected to earth test point all as specified or indicated including excavation and connected earth work in any type of soil, P.C.C 1:3:6 type C-1 as in pit., 40mm dia Gl pipe medium grade for Earthing lead protection pipe upto of 7.5 meter length, 20 mm bore Gl medium grade pipe for watering, 50mm thick R.C.C. 1:2:4 type B-1 cover slab of earth pit reinforced with 8mm dia TMT bars @ 10cm C/C both ways and with handle made out of 10mm dia bars, funnel, strainer and testing on completion including taking out uncerviceable earthing etc, complete all as specified and as directed. Note :-Old earthing may have been buried deeper than 2.25 mtr below ground level. Cost for excavation beyond 2.25 mtr deep to retrieve the old earthing, if done by contractor , shall not be made
M & L for plain cement concrete 1:4:8, type D-2, using 40 mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and as directed .
Supply , laying and fixing galvanised iron pipe of size 40 mm bore medium grade ISI marked including all necessary fittings and fixed to walls/ceiling or laid in floor etc, complete all as specified and as directed.
M&L for test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex. Head screw, complete all as specified and as directed by Engr-in-charge.
M&L for GI strip joint upto 150 mm length with 02 holes on each end with making hole 12mm with the help of electric drill machine includiing 12mm nuts, bolts and washer and welding upto 32 mm x 6 mm thick GI strip complete all as specified and as directed.
Dismantling and taking out old unserviceable cable any type and size upto 120 sqmm complete all as specified and as directed. Note :- Old U/G cable obtained from dismantling shall be taken on charge by BOO detailed by CWE. Serviceable cable shall be reused In maintenance work and unserviceable shall be disposed off as per existing policy, complete all as specified and as directed.
Supply and Laying of burnt bricks old size of Sub class 'B' designation 75 laid in trenches perpandicular to the cable for cable protection complete all as specified and directed by Engr-in- Charge
Horizental boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine induding HDPE pipe of 150 mm dla suitable for 0.4 mpa worldno oressure, complete all as specified and as directed
Supply , laying and fixing galvanised iron pipe of size 80 mm bore light grade ISI marked including all necessary fittings and duly laying through in trenches/on wall/under hardstanding path / road etc complete all as specified and as directed.
Supply , laying and fixing galvanised iron pipe of size 40 mm bore light grade ISI marked including all necessary fittings and duly laying through in trenches/on wall/under hardstanding path / road etc complete all as specified and as directed.
Supply , laying and fixing galvanised iron pipe of size 50 mm bore light grade ISI marked including all necessary fittings and duly laying through in trenches/on wall/under hardstanding path / road etc complete all as specified and as directed.
Supplying, laying, jointing, testing and commissioning under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 185 Sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape complete all as specified and as directed.
All as per item No - 2.48 above but size of cable 150 Sqmm 3.5 core complete all as specified and as directed.
All as per item No - 2.48 above but size of cable 120 Sqmm 3.5 core complete all as specified and as directed.
All as per item No - 2.48 above but size of cable 95 Sqmm 3.5 core complete all as specified and as directed.
All as per item No - 2.48 above but size of cable 70 Sqmm 3.5 core complete all as specified and as directed.
All as per item No - 2.48 above but size of cable 35 Sqmm 3.5 core complete all as specified and as directed.
All as per item No - 2.48 above but size of cable 25 Sqmm 4 core complete all as specified and as directed.
All as per item No - 2.48 above but size of cable 6 Sqmm 4 core complete all as specified and as directed.
All as per item No - 2.48 above but size of cable 10 Sqmm 4 core complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of the earth plate not less than 1.5 m below ground level surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to Gl earth strip 25x4mm by means of bolts, nuts,check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part- 1, connected to earth test point all as specified or indicated including excavation and connected earth work in any type of soil, P.C.C 1:3:6 type C-1 as in pit., 40mm dia Gl pipe medium grade for Earthing lead protection pipe upto of 7.5 meter length, 20 mm bore Gl medium grade pipe for watering, 50mm thick R.C.C. 1:2:4 type B-1 cover slab of earth pit reinforced with 8mm dia TMT bars @ 10cm C/C both ways and with handle made out of 10mm dia bars, funnel, strainer and testing on completion, complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of the earth plate not less than 1.5 m below ground level surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to Gl earth strip 32x6mm by means of bolts, nuts,check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part- 1, connected to earth test point all as specified or indicated including excavation and connected earth work in any type of soil, P.C.C 1:3:6 type C-1 as in pit., 40mm dia Gl pipe medium grade for Earthing lead protection pipe upto of 7.5 meter length, 20 mm bore Gl medium grade pipe for watering, 50mm thick R.C.C. 1:2:4 type B-1 cover slab of earth pit reinforced with 8mm dia TMT bars @ 10cm C/C both ways and with handle made out of 10mm dia bars, funnel, strainer and testing on completion complete all as specified and as directed.
M&L for earthing complete with copper earth plate electrode 60cm x 60cm x 3.15mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of the earth plate not less than 1.5 m below ground level surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to copper strip 20x3mm by means of bolts, nuts,check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of SSR Part- 1, connected to earth test point all as specified or indicated including excavation and connected earth work in any type of soil, P.C.C 1:3:6 type C-1 as in pit., 40mm dia Gl pipe medium grade for Earthing lead protection pipe upto of 7.5 meter length, 20 mm bore Gl medium grade pipe for watering, 50mm thick R.C.C. 1:2:4 type B-1 cover slab of earth pit reinforced with 8mm dia TMT bars @ 10cm C/C both ways and with handle made out of 10mm dia bars, funnel, strainer and testing on completion complete all as specified and as directed.
M&L for earth continuity conductor or main earthing lead of size 25x 4mm made of galvanised iron strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and as directed.
M&L for earth continuity conductor or main earthing lead of size 32x 6mm made of galvanised iron strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and as directed.
M&L for High galvanised mast light suitable for 12 lantern symmetrically fitted alongwilh their control gear and having three point suspension system with stainless steel wire rope of 6 mm dia 97/19 guage and double drum winch with luminaire mounting arm, pully, assembly, aviation obstruction light. lightening arrester spike including RCC foundation as per OEM’s design and specifications for height 30 mtr, complete all as specified and as directed. Note :- Note – [a] Technical specifications of high mast pole are enclosed as Annexure A-1. [b] Lights shall be mounted on the arms facing towards the apron. No and sizes (dia/thickness/lenth etc) of arms will be as per OEMs specification and approved by GE (AF) Chandigarh and no & capacity of lights on each arms shall be as per the illumination design prepared and verified by OEM. [c] Outdoor type floor mounted control panel with double doors with locking arrangements fabricated from 3.15 mm CRCA sheet and 50 x 50 x 5mm angle iron for frame and legs ( 04 nos legs minimum 750 mm long) PCC 1:2:4 foundation of suitable size dully powder coated 415 volts 50 Hz 4 wire system complete fitted with and including analogue type timer with battery backup, power contactors, relays , control MCBs , RYB indicators, wiring of circuits etc all as specified and direted suitable for switching ON/OFF of the lights fitted on the high mast pole. – 01 No with each high mast pole. [d] Trailing cable of size 4 sqmm 5 core copper conductor flexible round 1100 vots grade – 02 runs for each high mast pole [e] Unit rate quoted will be deemed to include the cost of above mentioned items in Note [c] and Note [d] and no extra payment will be made on this account. [f] Make of high mast light poles are Crompton Greaves/Havells/Bajaj/Wipro [g] Designing of illumination pattern for an Apron of 1200 x 240 mtr approximately by placing of high mast lights of height 30 mtr incl connected accessories along only one side of Apron to achieve minimum 15 Lux till 103 mtr from the pole edge of the Apron and minimum 4 lux at all the points of the Apron beyond 103 mtr and up to 240 mtr including undermentioed works complete all as directed :- [i] Designing of exact location of high mast light based on site survey by OEM, and foundation design/details of high mast light as per OEM.[ii] Cost of the design will be deemed To be included in the quoted rates and no extra payment will be made on this aspect. [iii] The quantity of flood lights of capacity 250 watt and 400 watt on each high mast pole will be as per design aspects/calculations and will be measured and paid under BOQ Sl Item No 2.63 and 2.64 respectively
Supply and fix , connecting and testing LED Flood light flitting 250 Watt, made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP - 66 protection, system efficacy not less than 110 LPW with and Including 10 KV SPD, complete all as specified and as directed.
Supply and fix , connecting and testing LED Flood light flitting 400 Watt, made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP - 66 protection, system efficacy not less than 110 LPW with and Including 10 KV SPD, complete all as specified and as directed. Note for item No 2.63 to 2.64 : - The design parameter of LED light fitting shall be restricted to installation of 250 watt and 400 watt capacity LED flood light fittings only. Qty catered for these items Is tentative and may vary as per design calculations.
Supply & testing installation and commissioning of outdoor type pole made up of 50mm dia , GI medium grade pipe duly painted with two coat of synlhitic enamell paint 1.2mtr including M&L for LED flood light fixture of 150W complete all as specified and as directed.
Supply , installation /fixing , connecting and commissioning of outdoor LT cubical panel of suitable size factory made, compartment type, dust and vermin proof IP-65 suitable for 1100 volt grade 3 phase, 50HZ AC, 4.wire supply, floor mounting fabricated out of 3.15 mm thick MS sheet CRCA quality welded on 50mmX50mmX5 mm size angle Iron frame of appropriate size having 04 Nos of angle iron legs made out of 50mm x 50 mm x 5mm 120 cm long and angle iron below frame with cable entry space in both side and with front door and back door opening having locking arrangement inter connected with aluminium strips and connected with suitable size thimbles/lugs with two coats of synthetic enamel paint over a coat of red oxide primer Including embedding legs in PCC 1:2:4 bed blocks of size 30 x30 x60 cm and 60 cm above the ground level , complete all as specified and as directed and complete with the following accessories . (For High mast fittings , SP-1 &SP-2)
Supply , installation /fixing , connecting and commissioning of outdoor LT cubical panel of suitable size factory made, compartment type, dust and vermin proof IP-65 suitable for 1100 volt grade 3 phase, 50HZ AC, 4.wire supply, floor mounting fabricated out of 3.15 mm thick MS sheet CRCA quality welded on 50mmX50mmX5 mm size angle Iron frame of appropriate size having 04 Nos of angle iron legs made out of 50mm x 50 mm x 5mm 120 cm long and angle iron below frame with cable entry space in both side and with front door and back door opening having locking arrangement inter connected with copper conductor strips and connected with suitable size thimbles/lugs with two coats of synthetic enamel paint over a coat of red oxide primer Including embedding legs in PCC 1:2:4 bed blocks of size 30cmx30cmx60cm and 60 cm above the ground level , complete all as specified and as directed and complete with the following accessories . (For High mast fittings , MP-1)
Supply , installation /fixing , connecting and commissioning of outdoor LT cubical panel of suitable size factory made, compartment type, dust and vermin proof IP-65 suitable for 1100 volt grade 3 phase, 50HZ AC, 4.wire supply, floor mounting fabricated out of 3.15 mm thick MS sheet CRCA quality welded on 50mmX50mmX5 mm size angle Iron frame of appropriate size having 04 Nos of angle iron legs made out of 50mm x 50 mm x 5mm 120 cm long and angle iron below frame with cable entry space in both side and with front door and back door opening having locking arrangement inter connected with aluminium strips and connected with suitable size thimbles/lugs with two coats of synthetic enamel paint over a coat of red oxide primer Including embedding legs in PCC 1:2:4 bed blocks of size 30cmx30cmx60cm and 60 cm above the ground level , complete all as specified and as directed and complete with the following accessories . (For Apron lights)
Supply , installation /fixing , connecting and commissioning of outdoor LT cubical panel of suitable size factory made, compartment type, dust and vermin proof IP-65 suitable for 1100 volt grade 3 phase, 50HZ AC, 4.wire supply, floor mounting fabricated out of 3.15 mm thick MS sheet CRCA quality welded on 50mmX50mmX5 mm size angle Iron frame of appropriate size having 04 Nos of angle iron legs made out of 50mm x 50 mm x 5mm 120 cm long and angle iron below frame with cable entry space in both side and with front door and back door opening having locking arrangement inter connected with aluminium strips and connected with suitable size thimbles/lugs with two coats of synthetic enamel paint over a coat of red oxide primer Including embedding legs in PCC 1:2:4 bed blocks of size 30cmx30cmx60cm and 60 cm above the ground level , complete all as specified and as directed and complete with the following accessories . (For BPs 3, 4, 5, 14)
Supply , installation /fixing , connecting and commissioning of outdoor LT cubical panel of suitable size factory made, compartment type, dust and vermin proof IP-65 suitable for 1100 volt grade 3 phase, 50HZ AC, 4.wire supply, floor mounting fabricated out of 3.15 mm thick MS sheet CRCA quality welded on 50mmX50mmX5 mm size angle Iron frame of appropriate size having 04 Nos of angle iron legs made out of 50mm x 50 mm x 5mm 120 cm long and angle iron below frame with cable entry space in both side and with front door and back door opening having locking arrangement inter connected with aluminium strips and connected with suitable size thimbles/lugs with two coats of synthetic enamel paint over a coat of red oxide primer Including embedding legs in PCC 1:2:4 bed blocks of size 30cmx30cmx60cm and 60 cm above the ground level , complete all as specified and as directed and complete with the following accessories . (Near BP-12 Bldg & high mast lights)
Supply , installation /fixing , connecting and commissioning of outdoor LT cubical panel of suitable size factory made, compartment type, dust and vermin proof IP-65 suitable for 1100 volt grade 3 phase, 50HZ AC, 4.wire supply, floor mounting fabricated out of 3.15 mm thick MS sheet CRCA quality welded on 50mmX50mmX5 mm size angle Iron frame of appropriate size having 04 Nos of angle iron legs made out of 50mm x 50 mm x 5mm 120 cm long and angle iron below frame with cable entry space in both side and with front door and back door opening having locking arrangement inter connected with aluminium strips and connected with suitable size thimbles/lugs with two coats of synthetic enamel paint over a coat of red oxide primer Including embedding legs in PCC 1:2:4 bed blocks of size 30cmx30cmx60cm and 60 cm above the ground level , complete all as specified and as directed and complete with the following accessories . (For BPs 3, 4, 5, 14)
Supply , installation /fixing , connecting and commissioning of outdoor LT cubical panel of suitable size factory made, compartment type, dust and vermin proof IP-65 suitable for 1100 volt grade 3 phase, 50HZ AC, 4.wire supply, floor mounting fabricated out of 3.15 mm thick MS sheet CRCA quality welded on 50mmX50mmX5 mm size angle Iron frame of appropriate size having 04 Nos of angle iron legs made out of 50mm x 50 mm x 5mm 120 cm long and angle iron below frame with cable entry space in both side and with front door and back door opening having locking arrangement inter connected with aluminium strips and connected with suitable size thimbles/lugs with two coats of synthetic enamel paint over a coat of red oxide primer Including embedding legs in PCC 1:2:4 bed blocks of size 30cmx30cmx60cm and 60 cm above the ground level , complete all as specified and as directed and complete with the following accessories . (For BPs)
Supply , installation /fixing , connecting and commissioning of outdoor LT cubical panel of suitable size factory made, compartment type, dust and vermin proof IP-65 suitable for 1100 volt grade 3 phase, 50HZ AC, 4.wire supply, floor mounting fabricated out of 3.15 mm thick MS sheet CRCA quality welded on 50mmX50mmX5 mm size angle Iron frame of appropriate size having 04 Nos of angle iron legs made out of 50mm x 50 mm x 5mm 120 cm long and angle iron below frame with cable entry space in both side and with front door and back door opening having locking arrangement inter connected with aluminium strips and connected with suitable size thimbles/lugs with two coats of synthetic enamel paint over a coat of red oxide primer Including embedding legs in PCC 1:2:4 bed blocks of size 30cmx30cmx60cm and 60 cm above the ground level , complete all as specified and as directed and complete with the following accessories . (For BPs )
Supply , installation /fixing , connecting and commissioning of outdoor LT cubical panel of suitable size factory made, compartment type, dust and vermin proof IP-65 suitable for 1100 volt grade 3 phase, 50HZ AC, 4.wire supply, floor mounting fabricated out of 3.15 mm thick MS sheet CRCA quality welded on 50mmX50mmX5 mm size angle Iron frame of appropriate size having 04 Nos of angle iron legs made out of 50mm x 50 mm x 5mm 120 cm long and angle iron below frame with cable entry space in both side and with front door and back door opening having locking arrangement inter connected with aluminium strips and connected with suitable size thimbles/lugs with two coats of synthetic enamel paint over a coat of red oxide primer Including embedding legs in PCC 1:2:4 bed blocks of size 30cmx30cmx60cm and 60 cm above the ground level , complete all as specified and as directed and complete with the following accessories . (For BPs )
Disconnecting electrical connnections from LT panels and taking out existing LT panel and keeping aside and re-positioining the same to other side , grouting the same in true position with PCC 1:2:4 types B2 using 40 mm graded coarse aggregate and making electrical connections, minor repair work for function of LT panels and painting with two coat of super enamelled first grade quality paint over one coat of red oxide primer and fixing of danger notice plate 440 Volt with conventional skull and bones in red signal colour - 01 No and testing complete all as specified and as directed
M&L for painting to LT panels with two coat of super enamelled first grade quality paint ovar one coat of red oxide primer and fixing of danger notice plate 440 Volt with conventional skull and bones in red signal colour - 01 No and testing complete all as specified and as directed.
S & F MCCB 100 Amps 4 ploe, 415 V with Rupturing Capacity 16 KA complete all as specified and as directed (for MP-1 & MP-2)
Supply and fix water proof ABS electric distribution box, wheather proof IP-65 suitable for out door use pole mounted made of MS factory made of size 300 x 250 x 150 mm comprising of MCB SP 6 Amps, 240 volts SPN bus bar not less than 25x5mm aluminium strip and fixing clamps of size 25 x 5 mm two nos including necessary MS nut, bolts and locking arrangment with lock pressure type, connection hole in four Nos each bus bar with nuts, bolts, and washer made of galvanise iron and connection thimble etc, complete all as specified and as directed
M&L for factory made LT feeder pillar box of size 750mm x 750mm x 600mm, with 4 strip copper bus bar (200 Amps, 1100 volt grade, 600mm long duly sleeved with relvant coloured sleev = 01 set) cubical outdoor type weather proof, fabricated out of 3.15 mm thick MS sheet, welded on 40mmX40mmX6mm long below angle iron frame and having 4 Nos of angle iron legs made out of 40mmx40mmx6mm - 120cm long below frame grouted on ground with PCC 1:3:6 of suitable size with front , rear door having locking arrengement openable, button space for cable entry with and including painted darken grey with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as directed
S & F off load front operated change over switch 415V in sheet metal enclosures 4 pole of capacity 63 Amps and connections, complete all as specified and as directed
M&L for 40mm bore steel water tubing medium grade (ISI marked) Galvanised with and including all fittings (ISI marked) laid in tranches and fixed complete all as specified and as directed.
M&L for 25mm bore steel water tubing medium grade (ISI marked) Galvanised with and including all fittings (ISI marked) laid in tranches and fixed complete all as specified and as directed.
M&L for 20mm bore steel water tubing medium grade (ISI marked) Galvanised with and including all fittings (ISI marked) laid in tranches and fixed complete all as specified and as directed.
Supply and fixing of sluice valves, ISI marked flanged of class PN 1.6, supplied and installed of size 150mm dia, complete all as specified and as directed.
Supply and fixing of sluice valves, ISI marked flanged of class PN 1.6, supplied and installed of size 80mm dia, complete all as specified and as directed.
S&F stop valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe of size 50mm bore and fixed complete all as specified and as directed.
S&F stop valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe of size 40mm bore and fixed complete all as specified and as directed.
S&F stop valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe of size 25mm bore and fixed complete all as specified and as directed.
S&F bib tap standard of PTMT any colour, high pressure, screwed for iron pipe and fixed (Min weight- for 15mm- 90 gms/20mm-125 gms) complete all as specified and as directed.
M&L for cutting existing CI / GI steel tubing upto 80mm dia for alterations or additions and making connection with providing Tee, Socket, reducer etc of size 50mm bore complete all as specified and as directed
M&L for cutting existing CI / GI steel tubing upto 50mm dia for alterations or additions and making connection with providing Tee, Socket, reducer etc of size 50mm bore complete all as specified and as directed
M&L for cutting existing CI / GI steel tubing upto 40mm dia for alterations or additions and making connection with providing Tee, Socket, reducer etc of size 50mm bore complete all as specified and as directed
Material and labour for construction of brick masonry valve pit of size 90cmx90cmx90cm (internal dimension) with frame of angle iron work of size 40 x 40 x 6 mm and MS sheet cover 3mm thick and locking arrangements and handle duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, including all excavation and connected work, complete all as specified and directed by Engr-in-Charge.
All as per item No 3.02 above but internal dimension 60cmx60cmx60cm
M & L for CI fittings up to 150mm dia with Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs all as specified and directed by Engr-in-charge
EARTHWORK AND EXCAVATION
Excavation in trenches n exc.1.5 m deep and n.axe 1.50m width and getting out in soft / loose soil for foundation of wall/ ploe, laying of cable or pipe etc, complete all as specified and as directed.
M&L for returning and filling including spreading and levelling and well rammming in layers n. exc. 25 cm in soft / loose soil complete all as specified and as directed
M&L forming embankments including raising (or lowering ) solids earth spreading in layers n exc 30 cm thick watering ramming / rolling and finishing to reqd size shape etc n exc 1.50m high from base and incl bring the soil by excavation over area in borrow pit at distance exc 1.50km to 5km complete all as specified and as directed
M&L forming embankments including raising (or lowering ) solids earth spreading in layers n exc 30 cm thick watering ramming / rolling and finishing to reqd size shape etc exc 1.5m but n exc 3.0m high from base and incl bring the soil by excavation over area in borrow pit at distance exc 1.50km to 5km complete all as specified and as directed
M&L forming embankments including raising (or lowering ) solids earth spreading in layers n exc 30 cm thick watering ramming / rolling and finishing to reqd size shape etc exc 3.0m but n exc 4.5m high from base and incl bring the soil by excavation over area in borrow pit at distance exc 1.50km to 5km complete all as specified and as directed
M&L forming embankments including raising (or lowering ) solids earth spreading in layers n exc 30 cm thick watering ramming / rolling and finishing to reqd size shape etc exc 4.5m but n exc 6.0m high from base and incl bring the soil by excavation over area in borrow pit at distance exc 1.50km to 5km complete all as specified and as directed
M&L surface dressing and removing vegetation not exceeding 15cm deep and getting out in soft/loose soil along the runway shoulder including grass vegetation, shurbs and earth work upto width of 30 ft from the edge of runway, taxiway, surrounding blast panes or plaza area similar work and removing vegetation and scraped surfaced even and neat look at site, complete all as specified and as directed
Excavation over areas, n, exc. 1.5M deep and getting out in soft /loose soil, complete all as specified and as directed
Removal of surplus soil to a distance n. exc. 50mtr and depositing where directed at a level not exc 1.5mtr above the starting point complete all as specified and as directed, complete all as specified and as directed
Surface excavation in hard / dense soil not exceeding 30 cm deep and averaging 15 cm deep and getting out complete all as specified and as directed.
Removal of surplus soil to a distance exc 500mtr but not exc. 1.5 Km and depositing where directed at a level not exc 1.5mtr above the starting point complete all as specified and as directed.
M&L for clean dry river sand / fine sand, filling under floor or in foundations includinh watering and well ramming in layer n. exc. 25 mm each or cushioning above /below the under ground cable total depth of sand shall be 23cm, 8 cm below and 15 cm above the cable) Punned to 18 cm (punned depth 18 cm shall be measured and recorded for paymant pursoses) complete all as specified and as directed
Note :-Schedule of credit Rs 141858.00 will be deducted from total quoted amount while calculating contract sum.
R D Bansal
NITYA NAND AND SONS CONTRACTORS PVT LTD
A.S. CONSTRUCTION CO.
shree balaji builders
Onkar Nath Bhalla And Sons Contractor Pvt. Ltd.
A K BANSAL AND CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .