Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹12.5 L+₹84,360 (7.22%)Rejected-Finance 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 | JAMNAGAR | GUJARAT | 361001 | L2 | Rejected-Finance Being L2 |
Tender Value
Refer Docs
EMD Value
₹28,000
Closing Date
22 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF BARODA
GE AF BARODA PO MAKARPURA BARODA 390014
REPAIR AND MAINTENANCE OF SUMMER APPLIANCES AT MAKARPURA AF STATION BARODA
2020_MES_371490_1
8564/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE AF BARODA
AS PER TENDER DOCUMENTS AND NIT
3 documents required · 3 mandatory
₹500
GE AF BARODA
₹28,000
Yes
27 Nov 2020
24 Aug 2020
25 Sept 2020
24 Aug 2020
22 Sept 2020
10 Sept 2020
26 Aug 2020 - 30 Aug 2020
60 days
Amount
Material and labor for replacement of unserviceable cut sealed compressor of window type/split type ACs 1.5TR capacity with new uncut sealed hermetically compressor unit supplied by the manufacturer complete unit including wiring as required to unit with flushing out system checking and rectification of leakage, including gas charging complete and testing after completion of work at MES store yard for satisfactory functioning complete all as specified and directed. NOTE:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms & conditions (ii) The new compressor unit will be purchased from authorized dealers only as per existing make and model
Material and labor for replacement of unserviceable cut sealed compressor of split type ACs 2TR capacity with new uncut sealed hermetically compressor unit supplied by the manufacturer complete unit including wiring as required to unit with flushing out system checking and rectification of leakage, including gas charging complete and testing after completion of work at MES store yard for satisfactory functioning NOTE:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms & conditions. (ii) The new compressor unit will be purchased from authorized dealers only as per existing make and model
Material and labor for replacement of unserviceable cut sealed compressor of split type Invertors ACs 1.5/2TR capacity with new uncut sealed hermetically compressor unit supplied by the manufacturer complete unit including wiring as required to unit with flushing out system checking and rectification of leakage, including gas charging complete and testing after completion of work at MES store yard for satisfactory functioning NOTE:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms & conditions. (ii) The new compressor unit will be purchased from authorized dealers only as per existing make and model
Material and labor for rewinding of blower motor of Speed 900 RPM of window/Split Air conditioner of capacity 1.5/ 2 ton any make with super enameled copper conductor including replacement of worn out bushes ,Shaft and capacitor etc complete all as specified and directed.
Material and labour for replacement of Swing motor for indoor unit of window/Split Air conditioner of cap 1.5/2 TR complete all as specified and directed.
Material and labour for replacement of condensor fan motor of Speed 900 RPM of window/Split Air conditioner complete all as specified and directed.
Supply and fixing running capacitor clip type of cap. 50Hz 6 MFD, 240 volts 50 cycles for window type/Split type air conditioner 1.5 Ton Cap complete all as specified and directed.
Supply and fixing over load protector with relay No 1622/2085 complete all as specified and directed. (Make:- Shri Ram/Renutral) for 1.5 Ton cap for window type AC.
Material and labour for replacement of thermostat switch for AC cap.1.5/2.00 ton capacity complete all as specified and directed. (Make:- Anupurna/Indofost No 2059/Ranutrol)
Material and labour for replacement of defective wiring set (with suitable copper wire) of window type AC cap. 1.5 Ton/2 Ton complete all as specified and directed.
Material and labour for replacement of defective wiring set (with suitable copper wire) of split type AC cap. 1.5 Ton/2 Ton (Both indoor and outdoor unitc complete all as specified and directed.
Material and labour for flushing out system, checking and rectification of leakages if any and make it serviceable including gas charging with refrigerant R-22 , oil charging complete in compressor window type AC/ Split type AC cap.1.5/2 Ton complete all as specified and directed. Note: Once the system is repaired and gas is charged, the contractor shall stand responsible for any leakage and recharging of gas for next one year from the date of repair without any extra cost.
Material and labour for flushing out system, checking and rectification of leakages if any and make it serviceable including. gas charging with refrigerant R -32 , oil charging complete in compressor window type AC/ Split type AC cap.1.5/2 Ton complete all as specified and directed. Note: Once the system is repaired and gas is charged, the contractor shall stand responsible for any leakage and recharging of gas for next one year from the date of repair without any extra cost.
Material and labour for flushing out system, checking and rectification of leakages if any and make it serviceable including gas charging with refrigerant R-410 , oil charging complete in compressor window type AC/ Split type AC cap.1.5/2 Ton complete all as specified and directed. Note: Once the system is repaired and gas is charged, the contractor shall stand responsible for any leakage and recharging of gas for next one year from the date of repair without any extra cost.
Material and labour for replacement of cooling coil for indoor unit split type AC Cap.1.5 /2.0 TR complete all as specified and directed.
Material and labour for replacement of copper condenser unit (Heating Condenser) for out door unit for split type AC Cap.1.5 /2.0 TR complete all as specified and directed.
Material and labour for chemical wash for indoor/out door unit for split /window type AC Cap.1.5 /2.0 TR complete all as specified and directed.
Material and labour for replacement of cooling coil for window type AC Cap.1.5 /2.0 TR
M/L for replacement of blade of condensing fan motor (as per sample) for window/split type (outdoor unit) AC cap 1.5/2.0 Ton. (existing make) complete all as specified and directed.
Material and labour for taking out window type AC from site of any capacity and any make for servicing including cleaning with air blower , cleaning and washing fins of cooling coil with caustic soda mixed water, taking out all dirt , sludge deposited, cleaning of air filter incl. oiling / greasing of condensing fan motor , spray painting of outer cover with 2 coats of synthetic enameled paint of approved colour as directed with writing of serial No SM/MES No. and reinstalled the AC in position with fixing of putty etc complete all as specified and directed. (Note : Any damage occurred during repair for which contractor will be responsible to rectify defects without any cost to the Govt).
Material and labour for servicing /overhauling of split type AC unit capacity 1.5/2.0 Ton including painting to outer cover and components with two coats of synthetic enameled paint of colour complete all as specified and directed.
Supply in fix in repairs of following unserviceable item in existing split type AC of existing make complete all as specified and directed.
Capacitor 4 MFD.make :Epcos/texla
Connector unit
Capacitor 2.5 MFD make:Epcos/texla
Foam type insulating flexible pipe fitted on suction /discharge copper tubes.
PCB Card for split type AC of capacity 1.5 TR
PCB Card for split type AC of capacity 2 TR
Remote hand set for split type AC 1.5/2 TR Capacity
Valve 1/2 " ,1/4 " and 5/8 " for split type of capacity 1.5/2.0 TR
Cooling coil and room temperature sensor
Display unit for 1.5/2 Ton AC
Blower motor of indoor unit of split type of cap 1.5 /2 TR as per existing make/model
Copper pipe of size 1/4 " from outdoor unit to indoor unit including soldering and brazing
Copper pipe of size 1/2 " from outdoor unit to indoor unit including soldering and brazing
Copper pipe of size 5/8 " from outdoor unit to indoor unit including soldering and brazing
PT relay for split type Acs of Capacity 1.5/2 TR as per existing make
Airfilter for split type ac for 1.5/2 TR and all as directed by Engr-in-charge.
Out unit jali for split type ac for 1.5/2 TR and all as directed by Engr-in-charge.
Outdoor fan motor as per existing Make for 2.0 Ton Spilt AC
Outdoor fan motor as per existing Make for 1.5 Ton Split AC
Compresser Capacitor as per existing Make for 1.5/2.0 Split type AC
Swing Patti as per existing Make for 1.5/2.0 Split type AC
Drain pipe as per existing Make for 1.5/2.0 Split type AC
Drain tray as per existing Make for 1.5/2.0 Split type AC
PCB Transformer as per existing Make for 1.5/2.0 Split type AC
PCB for 1.5/2.0 Ton Invertor type AC as per existing Make.
Fan motor of 1.5/2.0 Ton split type invertor Acs as per existing Make.
Outdoor heating condenser of 1.5/2.0 Ton split type invertor Acs as per existing Make.
Sensor of 1.5/2.0 Ton split type invertor Acs as per existing Make.
Control remote of 1.5/2.0 Ton split type invertor Acs as per existing Make.
Taking down carefully existing split type AC of capacity 1.5/2 TR (complete unit) and refixing the same from one site to another site as per users requirement complete all as specified and directed.
Servicing of all type Air conditioning including cleaning indoor filter, outdoor assembly and reinsulation of worn out insulation materials complete all as specified and directed.
Material and labour for replacement of electrical sub main wiring two run of single core 6 sq mm (Nominal area) multithreaded copper conductor PVC insulated sheathed cable including one run of 4 Sqmm solid copper conductor PVC insulated cable in and including 20 mm dial rigid metallic conduit complete including junction boxes with metallic sheet top cover and other accessories complete all as specified and directed. NOTE:- Two run of main wire, one run of earth wire and pipe shall be measured as one length.
supply and fixing single pole and neutral enclosure with 2 pin earth industrial plug and socket complete with one MCB SP 25 Amps complete all as specified and directed.
Material and Labour for replacement of unserviceable hermitically sealed compressor suitable for water cooler cooling capacity 40 liters/hour with new uncut sealed compressor supplied by manufacture complete. (Makes :-Tecumesh/Kirlosker copeland or existing make) Note:- i) Old sealed compressor received from the water cooler will be property of contractor ii) The ate quoted by the contractor including all charges like transportation , filling oil & gas charging incl flushing out system ,checking and rectification of leakage etc and testing complete up to entire satisfaction of Engr-in-charge with necessary guarantee period as per the company terms and condition iii ) The new sealed unit will be purchased from authorized dealer.
Material and Labour for Replacement of copper filter and capillary tube of water cooler cooling capacity 40 Ltr/hr complete all as specified and directed
Material and Labour for Replacement of relay with over load protectors for 40 Ltr/hr cooling capacity suitable as per site requirement complete all as specified and directed ( Make :Ranutrol/Rockwell/ Annapurna )
Material and Labour for Replacement of condensor fan of motor HP- 1/32 ,RPM-1300 suitable for water cooler having cooling cap 40 Ltr/hr with clips and motor fixing stand with fan blade complete all as specified and directed.
Material and Labour for Replacement of thermostat switch with knob for water cooler. having cooling capacity 40 Ltrs / hr complete all as specified and directed (Make : Renutrol no 1051 or Indofoss No2064/Annapurna )
Material and Labour for replacement of starting capacitor 40/60 Mfd oil filled 240 volt AC Supply complete all as specified and directed
Material and Labour for replacement of running capacitor of 10 Mfd oil filled complete all as specified and directed.
Material and Labour for replacement of capacitor of 3 Mfd complete all as specified and directed.
Material and Labour for replacement of brass float valve 15 mm bore with PVC float, ball I.S.I Marked complete with check nut /socket/GI nipple complete all as specified and directed.
Material and Labour replacement of top cover of water cooler with rubber beading to be provided as per sample kept in AGE E & M office including hinges screws etc complete for 40 Ltr/Hr cap. water cooler complete all as specified and directed.
Material and Labour for rewinding of condensing fan motor of water cooler (1/35 HP) cap. 40 Ltr/Hr with supper enameled copper wire of suitable gauge including insulating material and replacement of gun metal bush & capacitor 2.5 MFD complete all as specified and directed.
Material and labour for replacement of fan blade for condensing fan motor to be provided as per sample kept in AGE E & M office suitable for water cooler having cooling capacity 40 Ltr/Hr water cooler complete all as specified and directed.
Material and Labour for condenser unit complete suitable for 40 Ltr/Hr cap. water cooler repairs of leakages in system including gas charging flushing out the system brazing, welding and jointing the suction reed and discharge reed complete all as specified and directed.
Material and labour for flushing out system, checking and rectification of leakages if any and make it serviceable including gas charging with suitable refrigerant, oil charging complete in compressor of water coolar all as directed & with entire satisfaction of Engineer-in-Charge. Note: Once the system is repaired and gas is charged, the contractor shall stand responsible for any leakage and recharging of gas for next one year from the date of repair without any extra cost.
Material and labour for rewinding of Desert Cooler fan motor 3 speed,1400 RPM any make of cap. 1/5 HP with super enameled copper wire of appropriate size. including replacement of bush, shaft and oil filled capacitor 4 MFD,240 volts complete all as specified and directed.
Material and labour for replacement of oil filled type capacitor for fan motor capacitor 4 MFD , 240 volts suitable for desert cooler fan motor complete all as specified and directed.
Material and Labour for replacment of Bottom water tank of size 750x750x200 mm fabricated out of 18 gauge PGI sheet.incl nuts bolts and washers etc complete all as specified and directed.
Material and labour for replacement of side supporting columns to be fabricated out of 20 gauges PGI sheet of size 80x80x800 mm incl. necessary nut, bolts etc complete all as specified and directed.
Material and labour for replacement of side penal made out of 22 gauge PGI Sheet to be provided as per sample kept in AGE E & M office with suitable handles including painting to match with the existing desert cooler complete all as specified and directed.
Material and labour for replacement of top cover made out of 22 gauge PGI Sheet to be provided as per sample kept in AGE E & M office including painting to match with the existing desert cooler complete all as specified and directed.
Material and labour for painting to old steel surfaces of Desert cooler up to 5000 cfm with two coats of synthetic enamel spray paint over one coat of red oxide on external surface & two coats of anti corrosive black paint inside the Body tank & side grills over a coat of Red Oxide on internal surfaces including scraping/rubbing with wire brush on old surface of Desert cooler. and writing of MES NO etc complete all as specified and directed.
Material and labour replacement of submersible pump of discharge head 2.5 Mtr 220-240 Volts AC Supply single phase 40 watt complete all as specified and directed.
Material and labour for replacement of Wood / wool chips pad for Desert Cooler of size 550 x 550 x30 mm (set of three pads) superior qualitycomplete all as specified and directed.
Material and labour for replacement of supporting jali of wood/wool chips pad set made out of hard MS wire and fitted in side louvers complete all as specified and directed.
Material and labour for replacement of PVC insulated and PVC sheathed cable copper conductor 3 core 23/0.0076 cross sectional area superior quality complete all as specified and directed.
Material and labour for replacement of PVC water distributor of 3 out lets to be provided as per sample kept in AGE E & M office with MS nuts & bolts complete all as specifed and directed.
Material and labour for replacement of PVC elbow suitable for desert cooler to be provided as per sample kept in AGE E & M office complete all as specified and directed.
Material and labour for replacement of PVC pipe 15 mm dia heavy duty for Desert Cooler Pump complete all as specified and directed.
Material and labour for replacement of 3 pin plug top cap 5 Amp AC 240 Volts 50 Hz complete all as specified and directed.
Material and labour for replacement of motor fixing ring for desert cooler eight screw / clip type to be provided as per sample kept in AGE E & M office complete all as specifed and directed.
Supply and fix in repair voltage stablizer for automatic operation single phase naturally air cooled indoor type having low and high voltage cut-off protection, inbuilt thermal protection & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy +/- 2.5% and of capacity of 5 KVA wall mountable.complete all as specified and directed.
Material and labour for taking out deep frezzer of any size and any make to the workshop for general body work repairs including patch work and hinges and locking work complete after removing rusted part and repairing complete fabrication work what ever is required complete making it in good presentable condition after painting work complete all as specified and directed by EIC. Note: Rates for transportation to and fro from site to workshop shall be deemed to be considered in quoted rates.
Material and Labour for flushing of system , testing and repairs of leakages in system charging of Gas(between inner cooling cabin and outer fabrication) , Oil complete including testing and commissioning of deep frezzer of capacity upto 300 Ltrs of any make complete all as directed Note: Spares to be used in repair,gas charging and transportation to workshop and back to site shall be deemed to be considered in quoted rates.
Material and Labour for replacement of unserviceable hermitically sealed compressor suitable for deep freezer of capacity 300 Ltrs with new uncut sealed compressor supplied by manufacture complete. (Makes :-Tecumesh/Kirlosker copeland ) Note i) Old sealed compressor received from the water cooler will be property of contractor (ii) The rate quoted by the contractor including all charges like transportation, filling oil & gas charging incl flushing out system ,checking and rectification of leakage etc and testing complete up to entire satisfaction of Engr-in-charge with necessary guarantee period as per the company terms and condition. ( iii ) The new sealed unit will be purchased from authorized dealer.
Supply and fix in replacement of Desert cooler metal body tank capacity 50ltrs fan 1275 rpm heavy duty copper wound single phase motor cooling media as as per overall size 650mm X 650mm X 800mm consisting of thick metal sheet with inbuilt flotvalve 18 inch anti corresive painted fan & motor body complete and large pad area with heavy duty water circulating submercible pump with flexible pipe,delivers & acessories and power consumtipion 230V 50 Hz 235 watt complete, miniumum 2 years warranty by the dealer complete all as specified and directed.
Material and labour for replacement of unserviceable hermitically sealed compressor of Refrigerator 310/280 Ltr. Capacity with fresh new uncut sealed compressor including suitable relay and over load with new sealed unit as per the supplied by the manufacturer complete including flushing out system, checking and rectification of leakage, gas charging, complete and testing after completion of work at MES Store yard for satisfactory function. Note:- (i) The rate quoted by the contractor shall be inclusive of all charges like transportation, fitting etc complete with necessary guarantee period as per company terms and conditions. (ii) The new unit will be purchased from authorized delar. Make: Carrier/Voltas or existing make
All as per item No.94 above but for 165/170/180 Ltr capacity refrigerator complete all as specifed and directed. Make. Carrier/Voltas or existing make
Material and labour for replacement of relay suitable for 280/310 Liters cap.refrigerator complete all as specifed and directed. Make:- Renutrol/Shriram/Anpurna/KLIXON
All as per ser item No 96 but cap 165 Ltrs. Refrigerator
Material and labour for replacement of thermostat automatic `R' frost with knob suitable for 165/286/310 liters cap refrigerator complete all as specifed and directed. (Make :-Anpurna/Indofos)
Material and labour for replacement of door gasket of best quality complete suitable for 280/310 liters cap. refrigerator as per manufacturer's instruction complete all as specifed and directed.
All as per ser item No.99 above but for 165 Ltrs Cap.
Material and labour for replacement of Bulb for pin /screw type , 230 Volts suitable for 286/310 Ltrs Cap. refrigerator complete all as specifed and directed.
Material and labour for preparation of surfaces and painting with applying two coats of synthetic enamel paint old painted on external surfaces of refrigerator except cooling coil and the compressor unit which will be painted with two coats of heat resistant black paint for 286/310 ltrs capacity refrigerator including writing of the words in height unto 4cm i.e. SM No MES No complete all as specified and directed Note: Refrigerators to be painted at different locations of different units
All as per ser item No.102 above but 165 Ltrs capacity.refrigerator
Material and labour for replacement of refrigerator door handle of 165/ 286/310 Ltrs Cap. of any make.and model complete all as specifed and directed.
Material and labour for replacement of freezer assy (including gas charging R-134/600 ) complete with screw, jointing of tubes etc. and testing of cap. 280/310165 Ltrs. Refrigerator complete all as specifed and directed. (any make)
All as per ser item No.105 above but of capacity 165/175 Ltr refrigerator complete all as specifed and directed.
Material and labour for replacement of condensor unit of refrigerator cap. 280/310 Ltrs of any make including jointing of tubes and testing etc. complete all as specified and directed.(gas charging will be measure and paid under relevant item separately)
All as per ser item No.107 above but for 165 ltrs capacity refrigerator.
Material and labour for replacement of timer of refrigerator cap. 280/310/165 Ltrs of any make complete all as specifed and directed.
Material and labour for replacement of PCB of refrigerator cap. 280/310/165 Ltrs complete all as specifed and directed of make Hitachi/Voltas
M & L for replacement of cooling coil of refrigerator cap 280/310/165 Ltrs as per existing make complete all as specifed and directed.
M & L for replacement of capilary of refrigerator cap 280/310/165 Ltrs as per existing make complete all as specifed and directed.
Badri Electricals
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .