SE ETC II MORADABAD
220 KV S/S CAMPUS MAJHOLA MORADABAD
WORK OF REPLACEMENT OF 132 KV MAIN BUS FROM ACSR SINGLE TARANTULA CONDUCTOR TO ACSR TWIN MOOSE CONDUCTOR AGAINST AUGMENTATION OF 220 KV S/S AMROHA UNDER ETD AMROHA
2019_UPTCL_416864_1
E-T-314/ETC-II/M/2019
Open Tender
Electrical Works
60 days
AMROHA
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,770
EE ETD AMROHA
₹19,000
23 Jan 2020
27 Dec 2019
17 Jan 2020
27 Dec 2019
17 Jan 2020
27 Dec 2019
Amount
WORK OF REPLACEMENT OF 132 KV MAIN BUS FROM ACSR SINGLE TARANTULA CONDUCTOR TO ACSR TWIN MOOSE CONDUCTOR AGAINST AUGMENTATION OF 220 KV S/S AMROHA UNDER ETD AMROHA
Annexure A (Work) Cutting/Opening of single Tarantula conductor cross jumper among the three sections of each phase of existing 132 KV main bus and shifting of the recovered material from site to store.
Cutting/Opening of single Zebra/Panther Conductor jumper/ dropper of each phase of existing 132 KV main bus to bus isolator, shifting of material from site to store. There are 10 nos. 132 KV bays, each bay have 01 No. bus isolator and 03 Nos. of jumper/dropper. Thus total Nos. of jumper/droppers 10x3=30. (40 MVAR Bus side isolator jumper -03 Nos)
Cutting/Opening of single panther conductor from Bus isolator to 132 KV Circuit Breaker and shifting of the recovered material from site to store.
Dismantling of existing single Tarantula conductor of each phase of 132 KV main bus & shifting of the recovered material from site to store. There are 04 Nos. sections having 03 Nos. conductores in each sections.
Stringing of Twin moose conductor of each phase of 132 KV main bus with the help of single tension twin moose fitting alongwith spacers, hoisting of Disc insulators and other hardware at both ends of span & proper sagging including cutting, bending of conductor to & for shifting of the material from store to site. Each bus has 03 spans having 03 Nos. of twin moose conductors.Total nos. of section conductors. 4x3=12
Reconnection of Twin Zebra/ Panther jumper/dropper between each phase of 132 KV main bus and bus isolator including cutting bending of conductor alongwith spacers to & for shifting of material from store to site. There are 10 Nos. 132 KV bays, each bay have 01 No. bus isolator and 03 Nos. of jumper/dropper Thus total Nos. of jumper/droppers= 10x3=30.(40 MVAR Bus side isolator jumper -03 Nos)
Reconnection of Twin Zebra/Panther jumper from Bus isolator to 132 KV Circuit Breaker.
To connect twin moose cross jumpers with spacers, P.G. clamps etc. among three sections of newly stringed 132 KV main bus including cutting, bending of conductor, shifting of material from store to site. There are 04 sections having cross jumpers at three places. Total No. of crosss jumpers =3x3=9
Dismantling of 132 KV Single Zebra Conductor completely after opening of jumper and disconnecting complete dismantling work including shifting of the recovered material from site to store. (a) 160 MVA 220/132 KV T/F-I and II bay jumpering work. (b) 40 MVA 132/33 KV T/F-I & II bay jumpering work. Thus total no of jumpers is 6 nos. so 6x3x2bays=36
Stringing of twin Zebra conductor of each phase of 132 KV bay with the help of required hardware at both ends of span & proper sagging including cutting, bending of conductor, connection of twin jumpers/droppers in between jack bus & CB,LI, LV terminal, CT, LA & shifting of the materail from store to site for jack bus (a) 160 MVA 220/132 KV T/F-I and II bay jumpering work. (b) 40 MVA 132/33 KV T/F-I & II bay jumpering work. Thus total no of jumpers is 6 nos. so 6x3x2bays=36
ANNEXURE-B (SUPPLY) B) Following supply of material are required to carry out the augmentation work of 132 KV Main bus bar at 220 KV S/S Amroha. Bolted type Single tension fitting for twin moose conductor without turnbuckle.
Bolted type Single tension fitting for twin moose conductor with turnbuckle.
Bolted type Single suspension fitting for twin moose conductor.
Spacer for twin zebra conductor with 250 mm spacing.
Spacer for twin Panther conductor with 100 mm spacing.
Spacer for twin Zebra conductor with 100 mm spacing
Four Bolted type P.G Clamp suitable for Moose to Moose conductor.
Four Bolted type P.G suitable for Moose to Panther conductor.
Four Bolted type P.G suitable for Moose to Zebra conductor.
Three Bolted type P.G Clamp suitable for Panther to Panther conductor.
Supply of Isolator clamp for twin Panther conductor.
Supply of Isolator clamp for twin Zebra conductor.
145 KV Post Insulator Clamp for twin Panther Conductor.
145 KV Breaker Clamp for twin Panther Conductor
145 KV Breaker Clamp for twin Zebra Conductor
Supply of bi-metallic CT Clamp for twin zebra conductor
120 KV LA clamp suitable for twin panther conductor.
40 MVA Terminal connector HV side for twin zebra conductor.
160 MVA Terminal connector LV side for twin zebra conductor.
Shyam Constructions
Standard Engineering Works
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid