Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹7.3 LAccepted-AOC BALAJ COLONY SUBHASH NAGAR KAITHAL | JIND | HARYANA | 126101 | ₹7.3 L | L-1 | Accepted-AOC AOC |
| 2 | L-2₹7.4 L+₹17,660 (2.44%)Rejected-Finance | ₹7.4 L+₹17,660 (2.44%) | L-2 | Rejected-Finance Highest |
| 3 | L-3₹8.3 L+₹1.0 L (14.1%)Rejected-Finance | ₹8.3 L+₹1.0 L (14.1%) | L-3 | Rejected-Finance Highest |
Tender Value
₹8.2 L
EMD Value
₹16,400
Closing Date
15 Jul 2019, 5:00 pmClosed
Ritesh Nandal
Executive Engineer, Elect. Division PWD B and R Br., Ambala
Const. of Ghat and Renovation of Old Kuwa (Well) on Tirth at village Mangna (Pehowa) in Distt. Kurukshetra (CM Announcement No. 20284 dated 13.10.2017). (Pdg. EI) (Recall).
2019_HRY_79857_2
PWD/Elect-KNL/Elect-AMB/10525
Open Tender
Construction Works
Works
180 days
Ambala
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Executive Engineer, Elect. Division PWD Band R Br.
₹16,400
8 Nov 2021
3 Jul 2019
17 Jul 2019
3 Jul 2019
15 Jul 2019
3 Jul 2019
Amount
1 (I) Wires and Cables
Suply and erection of PVC copper insulated and sheathed 2-core circular flexible wire. (31.9)
1.1 Size 1.50 sqmm ( 48 / 0.20mm). ( 31.9 (i) d)
2 ( c ) Moulded case Circuit breakers.
Supply and erection of moulded case circuit breakers on wall or on existing pedestal including bonding to earth and necessary connections. (31.12 (c))
2.1 15 amp.to 60 amp. 415 V ,10 KA 3-phase. (31.12 c (i))
3 (L) Miniature Circuit Breaker and Isolator.
Supply and erection of miniature circuit breaker / isolator 240 /415 V in the existing distribution board including making necessary connections. (31.17)
3.1 SP MCB of 9 KA breaking capacity 6 amp. to 32 amp. (31.17a) (ii))
3.2 TPN MCB of 9 KA breaking capacity 6 amp. to 32 amp. (31.17(a) (ii))
4 (M) Supply and erection of Fittings and Accessories.
4.1 Erection only of 1x40 watts or 2x40 watts 1220 mm long / 1x20 watts or 2x20 watts ,610 mm long fluorescent tube fitting directly on wall including necessary connections with 0.75 sqmm ( 24 / 0.20 mm ) PVC copper flexible cable for connecting the tube with the adjecent point. (31.18 (xxiv))
5 (O) Erection and carriage of fans..
5.1 Erection of exhaust fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to he site of work. (31.20 (iii) )
6 (Q) Earthing (31.22)
6.1 Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. as required . (31.22(i))
6.2 Extra for using salt and charcoal / coke for pipe earth electrode as required. (31.22(ii))
6.3 Pdg. and laying earth connections from earth electrode with 4.00 mm dia G.I. wire in 15 mm dia G.I. pipe from earth electrode as required . (31.22(xii))
6.4 Pdg. and fixing 4.00 mm dia G.I.wire on surface or in recess for loop earthing as required . (31.22(xvi))
7 (S) Under Ground Cables.
Supply and erection of under ground cable ,loose in existing pipe or trenches complete with necessary connections . (31.26)
7.1 10 Sq. mm 2 Core Cable . (31.26 (iv) Ard.)
7.2 16 Sq. mm 4 Core Cable . (31.26 (xI) Ard.)
7.3 25 Sq. mm 4 Core Cable . (31.26 (xIi) Ard.)
8 Supply and erection of suitable compression type brass cable glands for underground Cable. (31.28)
8.1 10 Sqmm to 16 Sqmm Cable 2 to 4 Core . (31.28 (ii))
8.2 25 Sqmm to 50 Sqmm Cable 2 to 4 Core. (31.28 (iii))
8.3 Supply and erection of weather proof M.S.Box of size 20 cm x 15 cm x 10 cm. covered with 3.00 mm thick M.S.sheet hinged cover, housed in 1:2:4 cement concrete muff including suitable size of PVC pipe for in coming and out going cables, including the cost of 1 no. 16 amp. 415 volts kit-kat and 2 nos. 63 amp. 415 volts neutral links fixed on hard wood board in the M.S.Box including the cost of locking arrangement , painting and necessary connections etc. (31.30 (V) )
8.4 Muff size 40 cm. dia 50 cm .high. (31.30 (V) (i) )
9 (v) Pedestal .
9.1 Supply and erection of Godrej Almirah typeM.S.pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S.sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- (31.33)
9.2 M.S.pedestal of size 600 mm wide , 750 mm high ,300 mm deep and bottom totally open , duly embeded in cement concrete block of size 750 mm x 450 mm x 200 mm above ground level duly plastered with 12 mm thick 1:4 cement plaster , having a base of size 900 mm x 600 mm x 250 mm below ground level. (31.33 (i) )
10 (A) PVC Insulated wiring in recessed conduit.
Wiring in 1.5 sq.mm PVC Insulated copper conductor cable in 1.6 mm thick conduit pipe. (31.36)
10.1 Light point -Short. (31.36 (ii))
10.2 Light Point - Medium. (31.36)
10.3 Light Point- Long. (31.36)
11 S/E of of PVC unsheathed copper conductor cable single core 1100 volts grad in pipe of suitable size excluding cost and erection of pipe. (31.4)
11.1 Size 1.5 sqmm (3 / 0.81mm). ( 31.40 (i))
11.2 Size 2.50 sqmm (3 / 1.05mm). ( 31.40 (ii))
12 S/E of double door sheet steel enclosure distribution board suitable for MCBs and ELCBs recessed in wall including bonding to earth with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-Charge of the work. (31.41)
12.1 4-way, SP&N (Horizontal) (i))
13 S/E of mark double walled corrugated (DWC) HDPE pipe laid 1 Mtr. Below ground level including diging and refilling of earth including cost of suitable size socket cuppler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to entire satisfaction of Engineer- incharge of the work. (31.67)
13.1 HDPE Pipe 63/50 outer dia / inner dia. ((i))
14 Supply & errection of Hot Dip Galavnized octagonal pole of 3mm thickness, with base plate including cost of nut and bolts and all accessories as supplied by manufacture including cost of foundation accessories etc. The foundation bolts as per manfacturer design should be hot dipped galvanized pole to complete with door locking arrangement.Terminal plate consisting of 2 nos. 100 A, 4 pole natural links including connection etc. with suitble connecting arrangement for 2 no. MCBs/ kit kat including cost of R.C.C 1:1. 5:3 for foundation size 0.7M x 0.7M x 1.8M with minimum of 8 nos 12 mm dia longitudinal MS reinforcement rods with rings of 8mm dia not more than 200mm C.C for fixing the pole with all labour & material required to complete the job in all respect upto the entire satisfaction of Engineer in Charge of work. (31.68)
14.1 8 Mtr. Long pole with top dia 70mm and bottom dia 135mm with base plate of size 225x225x16mm. ((ii))
15 Supply and erection of LED Streetlight Luminaries 72 watt of Makes Bajaj & model No. BRTFG 72W LED I (169698) LED Street light made up of pressure die cast housing with toughned glass and individual LEDs with secondary optics and IP66 protection required to complete the job in all respect including erection on existing pole for fixing including connection of the same upto the entire satisfaction of Engineer in Charge of the work (Philips, Hevells & Crompton). (NS-1)
16 Supply & Erection of Single arms bracket made of 40mm dia GI pipe B class ISI 1.50 mtr. Long with coller of GI pipe 60cm Long duly fitted on Otacgonal pole and top covered with ornamental cap duly welded, painted 2 coats of aluminium paints on bracket and golden paint of ornamental cap including the cost of labour and petty material etc. to complete the job in all respect upto the entire satisfaction of Engineer-incharge. (NS-2)
17 Supply & erection of enclosure for MCCB 32/63 Amp. Complete with labour and material required to complete the job in all respect upto the entire satisfaction of Engineer-in-charge of work. (NS-3)
PK Technical Services
M/s Tripod Contractors
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .