Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹17.8 LAccepted-AOC | L-1 | Accepted-AOC Being the lowest bidder | |
| 2 | L-2₹18.0 L+₹22,502 (1.27%)Rejected-AOC | L-2 | Rejected-AOC Being other than the lowest bidder | |
| 3 | L-3₹19.8 L+₹2.0 L (11.4%)Rejected-AOC 129 A NICHLI CHOWKI DEVI NAGAR SECTOR 32 PANCHKULA HARYANA 134109 | PANCHKULA | HARYANA | 134109 | L-3 | Rejected-AOC Being other than the lowest bidder | |
| 4 | L-4₹22.8 L+₹5.0 L (28.0%)Rejected-AOC | L-4 | Rejected-AOC Being other than the lowest bidder | |
| 5 | L-5₹23.6 L+₹5.8 L (32.7%)Rejected-AOC | L-5 | Rejected-AOC Being other than the lowest bidder |
Tender Value
₹29.4 L
EMD Value
₹58,840
Closing Date
6 Jul 2020, 6:00 pmClosed
Commander Works Engineer, MES, Bareilly
HEADQUARTERS, COMMANDER WORKS ENGINEER, MILITARY ENGINEER SERVICES, STATION ROAD, BAREILLY CANTT, PIN 243001
CA NO.CWE BLY/GE (E)/ 17 OF 2020-21 REPAIR/ MAINT OF HT 11 KV UNDERGROUND CABLE AND CONNECTED WORKS UNDER GE (EAST) BAREILLY
2020_MES_350939_1
8200/B/625/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BAREILLY
For enlisted contractor Class D Category b ii and for unenlisted contractor meeting the eligibility criteria of class D and category b ii
6 documents required · 6 mandatory
₹500
GE East Bareilly
₹58,840
Yes
1 Sept 2020
8 Jun 2020
11 Jul 2020
8 Jun 2020
6 Jul 2020
23 Jun 2020
8 Jun 2020 - 29 Jun 2020
Amount
Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth and getting out in soft/loose soil for laying of under ground cable and foundation of poles complete all as specified and as directed.
Add to item No 1 for each additional 1.5m or part thereof in depth beyond the first 1.5 m for soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and as directed.
Removing of excavated soft/loose soil not exc 50 m and depositing where as directed at a level n.exc 1.5 m above from starting point. complete all as specified and as directed.
M&L for dry river sand for cushioning for protection of under ground cable in trench complete all as specified and as directed.
Supply and laying un-reinforced factory made precast concrete cable cover class HV type I flat of size 300mm x 180mm x 40mm complete all as specified and as directed.
Laying only old un-reinforced precast concrete cable cover retrieved from taking out of cable flat of size 300mm x 180mm x 40mm complete all as specified and as directed.
M&L for PCC type B1, 1:2:4 using 20 mm graded aggregate as in coping to the poles including necessary form work complete all as specified and as directed.
M&L for PCC 1:3:6 type C2 using (40 mm graded aggregate) in foundation, filing and mass concrete including necessary form work complete all as specified and as directed.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers welding, bending cold or hot, drilling holes for bolts, in any hape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed.
Dismantling of cross arms of MS channel or angle sections etc complete and setting aside for re-use with in 50 m complete all as specified and as directed.
M&L for Pin type , porcelain, vitreous, white , borwn or green insulator including one galvanised mild steel spindle , two galvanised mild steel spindle, two galnvanised iron wahers and one galvanised iron nut, 150 mm height,150 mm dia for 11000 volts grade complete all as specified and as directed.
S&F two in series disc porcelain, vitreous white/brown insulator 255mm dia and 145mm height two in series assembly for tension with tension clamps for conductor working pressure 11000 volts complete all as specified and as directed.
Dismantling insulators any type any size from HT/LT poles complete all as specified and as directed.
M&L for stay assembly complete with accessories of diameter of stay rod in 20 mm complete all as specified and as directed.
Dismantling stay assembly complete from the pole complete all as specified and as directed.
M&L Aluminium conductor, steel reinforced including stringing in position complete all as specified and as directed.
Dismantling of ACSR from the poles complete all as specified and as directed.
S&F galvanised steel stranded stay wire size 7/4mm for stay assembly complete all as specified and as directed.
S&F galvanised steel wire , cradle guards, hexagonal/rectangular fabricated of galvanised steel wire 3.15mm or 4 mm dia including binding wire aluminium complete cradle guard complete all as specified and as directed.
S&F in repair loop type insulator with complete fitting porcelain, vitreous white or brown large sizewith over all dismensions 90x140mm , clearance of hole 25.5mm complete all as specified and as directed.
Taking down or dismantling earth wire carefully complete all as specified and as directed.
Taking down or dismantling PCC poles complete all as specified and as directed.
M&L for steel tubular sewaged poles of complete with cast iron base plate, finial taper plate, bolts, nuts and screws, as specified type 410 SP-55 11 Mtrs long complete all as specified and as directed.
M&L for earthing complete with copper earth plate earth plate electrode 60cmx60cmx 3.15mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meter below normal ground level connected to copper strip 20x3 mm by means of bolts, nuts, check nuts and brass washer all as shown in electrical plate No 3 of SSR Part-I connected to continuous earth wire on pole all as specified and testing on completion, including provision of earth wire protected by 40mm dia GI light grade protection pipe from earthing plate to main board and 20mm GI medium grade watering pipe funnel, PCC earth pit and RCC cover charcoal, salt and GI wire including excavation and earth work etc complete all as directed at site.
M&L chemical earthing with copper earth plate 90cmx60cmx5mm & copper earth strip 32x6 mm complete all as specified and directed.
Supply, installing, testing and commissioning of Air-break, gang operated, triple pole switch, outdoor, vertical mounting type (ISI marked), mechanically operated, mounted on insulators 15 nos including 400 amp rating complete with (DO Fuse unit) fuse mounts, fuse carriers and HT fuse elements and frame work with operating mechanism worked from ground level, with locking arrnagments including Godrej pattern 65mm pad locks with two keys, complete suitable for HT 11 KV, 50 Hz AC supply including necessary electric connections, complete all as specified and directed.
Taking down old unserviceable Air break switch from the two/four pole structure complete all as specfied and directed.
Taking down old unserviceable earthing complete all as specfied and directed.
Taking down existing damage/unserviceable/faulty PVC insulated, armoured, aluminium conductor 11000V grade cable of any size and core from trenches, pipe, ducts, pole etc. testing for serviceability of cable, cutting and segregating serviceable portion for relaying serviceable cable complete all as specified and as directed.
Supply, laying, connecting and testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11 KV grade earthed laid in trenches/ ducts/ encased in GI pipe/fixed to pole including jointing and testing, size 95 sqmm 3 core complete all as specified and as directed.
Supply, laying, connecting and testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11 KV grade earthed laid in trenches/ ducts/ encased in GI pipe/fixed to pole including jointing and testing, size 120 sqmm 3 core complete all as specified and as directed.
Laying only serviceable11 KV XLPE insulated armoured cable obtained from item no 30 above complete all as specified and as directed. Note : Excavation and earth work will be paid and measured sepertely in relevant item.
S&F in repair cable end termination 11 KV HT (heat shirnkable) cable jointing kit for 11 KV ( Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 Sq mm complete all as specified and as directed.
S&F in repair cable end termination 11 KV HT (heat shirnkable) cable jointing kit for 11 KV ( Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sq mm complete all as specified and as directed.
S&F in repair straight through 11 KV HT (heat shirnkable) cable jointing kit for 11 KV ( Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sq mm complete all as specified and as directed.
S&F in repair straight through 11 KV HT (heat shirnkable) cable jointing kit for 11 KV ( Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 Sq mm complete all as specified and as directed.
S&F in repair lightening arrastor complete with 65 KA discharge capacity, transmission class suitable for 11000 Volts complete all as specified and directed.
M&L for 80 mm dia galvanised steel water tubing light grade, with all fitting, laid in trenches complete all as specified and as directed.
M&L for 100 mm dia galvanised steel water tubing light grade, with all fitting, laid in trenches complete all as specified and as directed.
M&L for painting the external exposed surfaces of steel tubular swaged/rail poles of 11 metres long alongwith cross arms, bracket and connected accessories with one coat of aluminium paint including preparation of old painted surfaces and writing the details of the pole in white letters on black back ground and pasting radium red strickers/paint with 3 lines around the pole complete all as specified and as directed.
M&L trimming/cutting of tree branches to provide proper clerancearound existing HT over head line up to 3 lines with clearance of 3mtr on both the sides from center of OH line all as per technical requirement including removing of cut treesbranches from site and depositing one place for burning/removing complete all as specified and as directed.
M&L for Cutting of bushes and cleaning the area around the sub station including two pole/four pole structures premises at Dadwara , Ex Mahararaja Land area and cutting the bushes, trimming the trees, complete all as specified and as directed.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm dia galvanised iron or strip complete all as specified and as directed.
S& F in repair HT cable/route indicator 100 mm dia 3 mm thick cast iron painted brown colour and fixed MS angle iron 25 x 3 mm, 60 cm long of suitable size along HT cable trench including planting in ground with PCC complete all as specified and directed.
S&F danger notice plate of 1.6 mm thick mild steel sheet vitreous enanelled white of size 20 x25 cm with figures letters and conventional skull bones in signal red colour and fixed with mild steeel clamps made of flat iron nuts bolts and washers etc for HT poles with voltage and danger indicated in hindi and english and local vernacular complete all as specified and as directed.
M&L for vice type connector consisting of two brass plates and two steel bolts for 2 conductor ( of size 4 to 07 mm dia ) unequal size for non tension connection including treatment of connector and ACSR conductor with conducting jelly complete all as specified and as directed.
Making drill hole of suitable size under road for laying pipe line of size 150mm bore at 1 metre depth from ground level complete all as specified and as directed. Note: Drill hole (trenchless) shall be done without disturbing top surfaces of road by appropriate machine.
M&L for anti climbing devices spikes type fabricated out of MS bars (round square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole for HT poles complete all as specified and as directed.
M&L in replacement old unserviceable HT jumpering from HT 4/2 pole structure to bus bar to GOD 3 Nos with HT cable 95 sqmm not less than 3 mtr complete including connector and lugs of suitable size with provision of Nuts & bolts washer etc complete all as specified and as directed.
M&L for hiring of cable fault locator machine for HT cables working voltage 11 KV to find out the fault in underground trench at different location up to 500 RM after locate fault charging the cable and jointing the cable on both side in RMU or over hed line complete all as specified and as directed. Note : Excavation and earth work will be paid and measured sepertely in relevant item
Note : Tenderers may note that amount of credit Rs 1,11,465.00 will be deducted from the total amount arrived, at the time of Acceptance of contract.
Ishtiaq and Sons
SONI ENTERPRISES
VINYAK TRADERS
Shree Balaji Constructions
SEEMA ELECTRICAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .