Superintending Engineer, Project Implementation Unit, Health & Family Welfare Department.
Supply, Installation, Testing and Commissioning of Semi Modular Operation Theatre At.SDH Bilimora & SDH Vansda,Dist. Navsari.
251370
2025-26/103/05
Open
Civil Works - Buildings
Navsari
1 document required · 1 mandatory
₹2,400
Yes
PIU-General Fund A/c 11-114
₹67,100
Yes
9 Dec 2025
9 Dec 2025
9 Dec 2025
27 Jan 2026
9 Dec 2025
Name Of Work:- Supply, Installation, Testing and Commissioning of Semi Modular Operation Theatre At.SDH Bilimora & SDH Vansda,Dist.
Sr. Total S.O.R Rate for 2024-25
No. quantities RATE RATE In Words UNIT TOTAL
Supply, Installation, Testing and Commissioning of 50 mm thick Pre Fabricated Modular Operation
Theater Panels (Walls and Ceiling) made out Polyurethane foam injected at 40 Kg/m3 sandwiched
0.8 mm thick GP and SP sheet on front side and 0.5 mm GP and SP/PPGI sheet on back-side. The inner
surface walls be fixed to the bricks wall with essential support. There will be minimum possible
cavity/gap in between solid and steel walls and will be variable to suit the architects lay out for the flush
mounting of the equipments. The wall and ceiling panels must comply with necessary provision of to JIS Rupees Six Thousand Five
1 226.82 Z 2801/ISO 22196, BS EN 1363-1:2020, EN 1363-2:1999, EN 1364-1:2015, DIN 6,550.00 Hundred Fifty and Zero Paisa Sq Mtrs.
52210-2:1984-08, DIN 4102-1, Class A2. Any Third-party compliance certificate mandatory. Panel Only
should be covered with protective sheath of 300 d.f.t Anti-bacterial Paint having undergone
Washability/Water resistance Test JIS K 5663.7.12, permeability test less than 200 unit of permeability,
Anti-bacterial effect against staphyloccoccus aureus, Escherichia coli (via HALO test) and safety and
causative agents such as formaldehyde, toluene, xylene, paradichlorobenzene etc. Third party (NABL
approved Lab) certification for EGP and thickness test certificate to be submitted
at time of supply.
Sr. Total S.O.R Rate for 2024-25
No. quantities RATE RATE In Words UNIT TOTAL
The flooring within the surgical theatre should consist of a minimum of 2mm thick antistatic seamless
PVC, ensuring durability and safety. This floor should be smooth, non-slip, and made from an
impervious material with sufficient conductivity to dissipate static electricity effectively, yet not so
conductive as to risk electric shock to personnel. The PVC used should be of very high quality,
particularly designed for electrostatic charge dissipation, and should not be less than 2 mm in thickness.
The installation process should utilize continuous rolls, and joints should be seamlessly welded using
special PVC thermal welding units with welding bars of the same color to ensure uniformity and prevent
contamination. The sheets should be highly durable, capable of resisting shocks, indentations, and
scratches. The conductive material should be uniformly impregnated within the PVC as grains to
enhance its antistatic properties. Additionally, the flooring should be inert to body fluids, chemicals, and
disinfectants, and remain unaffected by temperature variations typical within an operating theatre. It
should efficiently discharge electric charges up to 2 kV, and the electrical resistance (point to ground) Rupees Four Thousand Two
2 88.16 should be maintained within 2.5x10^4 to 5x10^6 ohms, ensuring no buildup of electrical charge beyond 4,250.00 Hundred Fifty and Zero Paisa Sq Mtrs.
100 volts. Floor installation should be performed by skilled workers from accredited agencies authorized Only
by the PVC sheet supplier. The installation should include a conductive copper grid beneath the PVC
sheet, supported by liquid epoxy compounds to create a uniform and level surface. Copper strips should
be made visible by grinding and not project more than 0.5mm above the floor level to prevent damage
to the PVC sheet, with one earthing lead brought out from every 150 sq.ft area and attached to the
main earthing strip/ground. The flooring should also be mechanically shockproof, scratchproof, flame
retardant, and antimicrobial. Corners of the flooring should be uniformly curved, and a concealed cove-
former (aluminium) should overlap the wall panel to a height of approximately 25mm and be sealed
perfectly and uniformly. Before laying the PVC, suitable self-leveling compounds should be used to
prevent any undulations within the operating theatre. The final surface should be non-corrosive to
biological fluids and detergents, with a color that is uniform, pleasant, and matching with the ambience
as approved by the respective consignee.
Sr. Total S.O.R Rate for 2024-25
No. quantities RATE RATE In Words UNIT TOTAL
The door to the surgical theatre should be a hermetically sealed, single sliding door measuring
meters in height and 1.5 meters in width. The door should be equipped with a controller capable of
being operated by elbow switches, foot switches, and a touchless sensor, providing multiple, accessible
control options. The track for the door should be made from stainless steel or aluminum, with the
running surface for the top rollers angled appropriately to minimize resistance and facilitate smoother
movement. The door leaf should be suspended using high-quality hard plastic rollers with double
bearings at the top. These rollers should run under the stainless steel or aluminum track to ensure
smooth and noiseless operation. The opening and closing mechanisms of the door should be controlled
by a microprocessor for precise electromechanical movement. The material of the door should be either
SMS or HPL, with a color that matches the interior design. The door should be designed to be strong yet
lightweight for ease of use. In case the automatic mechanism fails, the door should still be able to open
and close effortlessly manually. The handle of the door should be made from stainless steel with a
matte finish and equipped with a high-quality cylindrical or ESPg lock for security. The door leaf should Rupees Two Lakh Ninety Five
3 2.00 incorporate a high-quality synthetic rubber gasket with long durability to ensure hermetic sealing and 2,95,000.00 Thousand and Zero Paisa Nos.
maintain a 99.99% air tightness at a minimum pressure of 75Pa. The floor on either side of the door Only
should be perfectly level, with a maximum permissible difference of +1mm, to avoid any tripping
hazards or unsealed gaps. The overall thickness of the finished door should range from 30-60mm, with
the inner part of the door filled with CFC-free polyurethane foam, approximately 48mm thick, sealed
airtight to block any microbial ingress. The door and its controls should comply with IEE regulations,
utilizing DC brushless or PMDC motors that are effectively isolated from mains power to ensure safety
and reliability. Additionally, the door should include a vision window measuring 300mm x 300mm,
featuring double-glazed panels that are hermetically sealed to maintain the integrity of the seal.
The movement of the door should be as quiet as possible, and the time to start moving after
receiving a signal should be adjustable between 0.5 to 20 seconds.The door controller should be CE
marked, BIS certified, or IEC 60601 certified to meet international and national safety standards. A test
certificate for the hermetically sealed door frame should be included in the pre-dispatch documents to
verify compliance with the specified standards and functionality.
Sr. Total S.O.R Rate for 2024-25
No. quantities RATE RATE In Words UNIT TOTAL
Hatch boxes should be provided in each operating theater to facilitate the safe and efficient removal of
waste materials to the dirty linen area or adjacent corridor. Each hatch box should be equipped with
two doors, operated electrically or motorized, designed such that only one door can be opened at a
Rupees One Lakh Fifteen
time to prevent cross-contamination. UV lighting should be installed to ensure sterilization and should
4 2.00 1,15,000.00 Thousand and Zero Paisa Nos.
remain on when both doors are closed, automatically turning off when either door is opened. Indicators
should be provided on both sides of the operating theater to monitor the door open/close status. The
material of the hatch box should also be SS304 grade stainless steel, with a minimum size of 600mm x
Supply, Installation, Testing and Commissioning of Storage Units - Storage units should be constructed
with same material, as wall and ceiling panels. The shelves, made of glass and, should be removable for
Rupees Eighty Five Thousand
5 2.00 cleaning. The unit should be divided into two or more parts, each with individual glass doors equipped 85,000.00 Nos.
and Zero Paisa Only
with a high-quality locking system. The overall size of the storage unit should
be approximately 200 cm (H) x 120 cm (W) x 35 cm (D).
Supply, Installation, Testing and Commissioning of Double-Bay Scrub Sink - The scrub station should be
compact, designed for use in the OT complex, and facilitate pre-procedural scrubbing. It should be
made from heavy gauge type 304 stainless steel with a minimum thickness of 1.5mm and feature
seamless welded construction polished to a satin finish. The scrub sink should have a front access panel
Rupees One Lakh Twenty Six
for easy maintenance of water control valves, waste connections, stoppers, and strainers. Hands-free
6 2.00 1,26,000.00 Thousand and Zero Paisa Nos.
operation should be enabled through infrared sensors with programmable adjustments. Thermostatic
mixing valve control should maintain constant water temperature and be located behind the access
panel. Timing should be adjustable to meet individual usage requirements, and units should have
reduced anti-splash fronts. An additional knee/foot-operated switch should also be provided for
enhanced functionality.
Sr. Total S.O.R Rate for 2024-25
No. quantities RATE RATE In Words UNIT TOTAL
Single-arm surgery/anesthesia pendant designed for Operating Theatres should feature a compact,
modular configuration to meet the precise requirements of hospitals, enabling customization to suit
specific operational needs of both Operating Theatres and Intensive Care Units. It should be equipped
with robust ceiling support capable of mounting a selection of arms. The extension arm, pivotal for
functionality, should allow horizontal movement with a radius of 800-900mm and provide a level
rotation ranging from 0 to 330/340 degrees, with both the extension arm and terminal box designed to
rotate together and independently for maximum versatility. The pendant should support a net loading
capacity of min. 100 kg, accommodating a variety of medical instruments and devices securely. For
medical and electrical services, it should offer configurations that include at least two oxygen outlets,
two vacuum outlets, one medical air, one medical air at 7 bar, and an optional nitrous oxide outlet (In-
Rupees Two Lakh Eighty Four
scope of MGPS vendor) Additionally, there should be six main sockets, each capable of supporting 5 to
7 2.00 2,84,000.00 Thousand and Zero Paisa Nos.
15 amps, conforming to universal standards to facilitate the operation of various medical and electronic
devices. In terms of materials and construction, the pendant should be crafted from high-strength
aluminum alloy with a sealed design to enhance durability and maintain sterile conditions. The arm
itself should be made from high-density aluminum alloy extrusion, ensuring both strength and
reliability. Installation of the pendant should be ceiling-mounted to provide a reliable and firm setup,
optimizing space usage in the Operating Theatre or ICU while seamlessly integrating with existing
medical systems for managing medical gas, electrical services, data communication, and equipment.
Additionally, the pendant should include practical features such as a stainless steel IV pole and a ward
vacuum unit clamp to further enhance its utility in a medical setting. With a net weight of approximately
105 kg, accessible by the equipment carrier, the pendant should be robust yet manageable, ensuring it
meets the rigorous demands of modern medical environments.
Sr. Total S.O.R Rate for 2024-25
No. quantities RATE RATE In Words UNIT TOTAL
Double Dome OT Light with Ceiling mounted Double Dome LED OT lights having following features and
enclosed technical specifications, having Mobile App Connectivity, Battery Backup
-Light intensity Ec - 160 000 & 160 000 lux, - Light intensity adjustment - 10 – 100% (using Digital
Capacitive Touch (Fully Remote Controlled)
- Color temperature Tc (with adjustment)
-Light field diameter d10 at Ec - 100 - 150 mm
Rupees Three Lakh Ninety
-Working range - 1 m
8 2.00 3,90,000.00 Thousand and Zero Paisa Nos.
-Color rendering index 93Ra
- Focusing Preset: Adjustable
- LED Average life - 50000-60000 hrs
- Diameter of Light - not less than 650 mm per dome
- Power Consumption - not more than 120W
OT Light should be BIS marked; manufacturer should have CDSCO License for this product under Class
A, Compliant to IEC standards such as IEC60601-1:2005+A2:2020, IEC 60601-2-41:201 (Relevant Test
Certificates to be submitted with Bid) Clause-wise Technical Compliance to be
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded,
annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC - 227 erected
Rupees Eighty Seven and Zero
9 40.00 in existing pipe of following size (Specifically for control panel, relays, power switchgears, motor 87.00 Mtr
starters & control wiring) with required size of copper lugs, nuts and bolts if required.
(f) One wire 10.00 sq. mm
providing and erecting Mains with ISI marked, 1.5KV grade electrolyte multi stranded,
annealed copper conductor with heat resistant PVC insulated conforms to IS 694, IEC - 227 erected
in existing pipe of following size (Specifically for control panel, relays, power switchgears, motor Rupees One Hundred Thirty
starters & control wiring) with required size of copper lugs, nuts and bolts if required. Four and Zero Paisa Only
(g) One wire 16.00 sq. mm
Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted
fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 &
without MCB to house appropriate nos. of MCBs.(The DBs should be used of same company of MCB to Rupees Two Thousand Eight
11 2.00 be used) suitable for 2,885.00 Hundred Eighty Five and Zero Nos.
(B) three phase incoming and single phase horizontal type outgoing Per phase isolation type (PPI) Paisa Only
(b) sheet steel double door
Sr. Total S.O.R Rate for 2024-25
No. quantities RATE RATE In Words UNIT TOTAL
providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to operate on
Rupees One Hundred Eleven
12 36.00 240 V A.C. system and having breaking capacity 10 KA to be erected in existing box. 111.00 Nos.
and Zero Paisa Only
confirming to IS 8828/1996 with ISI Mark Cat.III
Providing & erecting 240 V MCB double pole switch for lighting Load (B Curve) having 10 KA
Rupees Two Hundred Seventy
13 12.00 breaking capacity & confirms to IS : 8828 in existing box having following capacity 276.00 Nos.
Six and Zero Paisa Only
(A) 6 to 32 Amp. Cat-III
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C Curve) having 10KA breaking
Rupees Six Hundred Sixty Two
14 8.00 capacity & confirms to IS :8828 in existing box having following capacity 662.00 Nos.
and Zero Paisa Only
(b)40 Amp. Cat III
Supplying and erecting triple pole & neutral 440V / 500V panel mounting Copper Busbars with
four equal Nos. of electrolyte bus having current density not more than 1.6 Amp. / sq.mm
Rupees Three Thousand One
(Rated current / cross section area) duly wrapped with colour insulating tape for phase sequence
15 2.00 3171.00 Hundred Seventy One and Nos.
of following current carrying capacity, erected with necessary bus bar supports /insulators, main
Zero Paisa Only
cable socket to each bar, erected in existing cubical panel with necessary connections.
(B) Suitable for 200 Amp. capacity
Providing and erecting Approved make Four pole moulded case circuit breaker having breaking
Rupees Sixteen Thousand
capacity ICU of 35 KA. at 415 V. having Normal current rating 200A.with variable Thermal &
16 2.00 16061.00 Sixty One and Zero Paisa Nos.
magnetic release suitable to work on A.C.supply 50 c/s. with all internal connections,
spreader tinned copper & complete erected in existing 16 G.M.S.housing
Sr. Total S.O.R Rate for 2024-25
No. quantities RATE RATE In Words UNIT TOTAL
Providing & erecting weather proof, dust & vermin proof, floor mounted front operated
indoor type cubical panel board necessary IP- 42 and above protection as per approval from engineer
incharge made from 14 SWG thick CRC M.S. sheet for outer body & doors, 16 SWG thick CRC
M.S.sheet for internal partitions with necessary accesories , supporting angles/ flats
channel including cutting, bending, drilling, welding, riveting with internal partitions & cable
alley as per requirements & instruction of engineer-in- charge with erection of supplied
switch gears, BUSBARS, suitable size of inter connecting PVC copper wire / copper-aluminium
strips, rubber grommets, rib, bakelite control fuses/MCB for measuring instruments, earth bus &
Rupees Fourteen Thousand
earth bolts, foundation flange - bolts-base Plates, sufficient nos. of hinged doors, handles
17 2.00 14,755.00 Seven Hundred Fifty Five and Sq.Mtr
with locking arrangement and rubber gasket,heavy duty end terminal connection,danger
Zero Paisa Only
notice board,necessary ventilation,earthing strip complete. The Panel shall be painted with
epoxy powder coating (The rates excludes the cost of switchgears, bus bars, inter connecting
mains & Copper Aluminium strips, meters, Fuses etc. The dimension shall be measured
excluding base beams) The panel shall be supplied with following approved manufacturers
following size.
(B) The standard companies switch gear shall be used and only manufacturers at CPRI
approved factory. (i) with 350mm depth board
Providing , erecting , fabricating the M.S. structure as per requirement on site
incorporating proper size of M.S. angles,square,round, flats, bars, channels, sections
complete with cutting, welding, grinding & finishing duly painted with one coat of red oxide Rupees Seventy Seven and
with erection on site as per direction of engineer in charge with necessary grouting, Zero Paisa Only
cementing, plastering & finishing
Supplying and erecting approved make suitable panel indicator LED type lamp, lens cover, Rupees Forty Three and Zero
complete erected with necessary connections. Paisa Only
Providing & erecting L.T. Current Transformer with bar primary 50/5 to 1000/5 ratio 15 VA burden Rupees Two Hundred Seventy
erected in existing CRCA box duly secured with insulating materials connected to the meter. Two and Zero Paisa Only
Providing and erecting Approved make Earth fault Relay suitable to mount with inter
connection suitable to following size of moulded case circuit breaker having CT ratio & MCCB Rupees Four Thousand Nine
21 2.00 rating as following along with shunt trip 220V AC. with all internal connections & complete 4934.00 Hundred Thirty Four and Zero Nos.
erected in existing M.S.housing. Paisa Only
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium
conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of Rupees Two Hundred Fifteen
following size of cables and Zero Paisa Only
(B) 3 1/2 core 35 Sq. mm ( 16 Sq. mm 1/2 core)
Sr. Total S.O.R Rate for 2024-25
No. quantities RATE RATE In Words UNIT TOTAL
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Copper conductor for
Rupees Six Hundred Seventy
23 100.00 KV. to be laid on wall with necessary clamps or in existing trench / pipe at road crossing or floor of 670.00 Mtr
and Zero Paisa Only
following size of cables. (A) 4 core 10 Sq. mm
Supplying & erecting earth pit of minimum bore dia.150mm size approved make Earthing
Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free hot dipped
G.I.Pipes having Outer pipe dia of 50mm having 80-200 Micron galvanising, Inner pipe dia of
mm having 200-250 Micron galvanising, connection terminal dia of 12mm with constant ohmic
value surrounded by highly conductive compound with high charge dissipation suitable for
following type of applications with chamber and heavy duty cover. (A)(approved make OEM
has to submit test certificate including value of earth resistance of installation duly
Rupees Four Thousand Five
stamped and signed by agency and officer Incharge has to ensure the value of earthing
24 8.00 4546.00 Hundred Forty Six and Zero Nos.
resistane mentioned in test Certificate) & having back filling compound of (B) Inner chemical
(CCM Compound)- Resistivity:- 0.2 ohm / meter testing as per IEC 62561-2017, Voltage drop:-
< 1 volt at no load & dry form, Sulphar content:-
<2%(C) Back fill Compound :- Earthing compound should be capable to retain moisture for
long time Necessary test report must be submitted by Agency.
(a) For Electrical Installation up to 440V in normal soil
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg.
Providing and erecting Annealed bare Copper Rupees Seven Hundred Eighty
wire 8 to 16 SWG. Seven and Zero Paisa Only
Supplying and erecting approved make online Un-interruptible Power Supply system comprising flat
cum-boost charger with IGBT base rectifier & Inverter & sealed maintenance free SMF batteries. The
charger having operating capacity for input 160-270V AC & inverter having output 230V,50 Hz Ac with Rupees Three Lakh Seventy
26 1.00 0.8 load power factor with battery, over/under voltage output with over load & short circuit protection 375000.00 Five Thousand and Zero Paisa job
equipment. The system housed in CRC sheet duly powder coated paint with following power Only
backup.with MS painted batteries stand, 10% Overload capacity for momentary load. (J) 25 KVA 3 -
phase with 1Hr Backup
HEPA Filter for Laminar Air flow -
Rupees One Lakh Ninety Two
Replacing of all Hepa Filters in planum size 2400mm x 2400mm for Laminar Air flow to make it
27 2.00 192700.00 Thousand Seven Hundred and nos
operational as per technical specification or as directed by Engineer Incharge . ( make:-existing HEPA
Zero Paisa Only
Filter make or equivalent & compitible with Laminar Air Flow and applicable standards)
Sr. Total S.O.R Rate for 2024-25
No. quantities RATE RATE In Words UNIT TOTAL
AIR HENDALING UNIT Make:KrVelocity: Not More Then 10 mt/second. , Canvass Connection-Heavy
duty, non partical shreding,Fire Retardentuger,Nikotra only , Type: PLUG,Drirect Driven,Dynamically
Balanced Selection of fan-Should run comfortably at 50 HZ at rated capecity. Motor
Make:Siemence,B.B,Crompton,ABB , Type:TEFC, IP:55, Foot Mounted, VFD compitable and I2
generation Safety: Motor should have interlocked with AHU Motor door/excess/Fire DamperType-TWO Rupees Twelve Lakh Twenty
28 1.00 TIRE, Floor Mounted , Inner const.:0.6mm plain G.I , Outer const.:0.8 mm G.I. Pre coated / Powder 12,25,000.00 Five Thousand and Zero Paisa Job
coated Thickness of Insulation: 25mm,PUF injected having density 40 to 42 kg/m3. ,Colour:As approved Only
by CLIENT CONDENSING UNIT :
Condensing unit for AHU with all assesories and instalation (Copper pipie provide 3 mtr Only Extra will
charged extra) consider 1200 sqfeet insulation and ducting
Rupees SixtySeven Lacs One Thousand Four Hundred ThirtyOne Only Say Rs.
In Words :=SixtySeven Lacs One Thousand Four Hundred ThirtyOne Only
I/We am/are willing to carry out the work at ..……..% below (percent should be written in figures and words) of the estimated rates mentioned above. Amount of my/our tender works out as under.
*Estimated amount Rs. 67,01,431.00 *Estimated amount Rs.
Put to tender Rs. 67,01,431.00 Put to tender Rs.
Deduct Below Rs. Add % Below Rs.
Net Rs. Net Rs.
*(please strike out whichever is not applicable)
1 All work shall be carried out as per Public Works Department Handbook and other specifications of Division or as directed.
2 All the columns is Schedule should be filled in ink and the total of the entries in the last column should be struck by the contractor under his signature.
3 Rates quoted include clearance of site (prior commencement of work and at its close) in all respects and hold good for work under all conditions, site, moisture, weather etc.
4 To be continued on additional sheets, if found necessary.
1 The Contractor shall exhibit a board with detailed specification and details of work as directed by the Engineer-In-Charge for which no extra payment shall be made.
2 The labour cess will be deducted as per prevailing rules i.e. 1% of the work done.
3 GST and Income tax TDS will be deducted at a source while making payments of bills
4 In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt. G.R.: PRC-10/2017 Cement Consumption/16/C Date:11/05/2017 as stated in of difference of
5 GST extra applicable in case of work based on SOR 2024-25 only.
Dy. Executive Engineer Executive Engineer
Project Implementation Unit Project Implementation Unit
Navsari Navsari
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Condition for cement.pdf
GR RnB Revise.pdf
GR-TMT-Lap Length.pdf
INSTRUCTIONS TO PERSON TENDERING.jpg
JPG
Performance Bond and SD-Paripatra-2023.pdf
PIU SPECIAL CONDITIONS.pdf
Inclusion of Insurance clause as per new SBD.pdf
6372 Make List HO 15.10.2025.pdf
PQ OT.pdf
Specification.pdf
Schedule B.pdf
SBD.pdf
Tender Document.pdf
Revised Tender Document.pdf
Revised PQ.pdf
Corrigendum For revised Point No.6.pdf
Pre Bid Meeting Clearification.pdf
Sdh bilimora .pdf
sdh vansda.pdf
Re Revised PQ.pdf
Revised Specification.pdf
Corrigendum for Certification.pdf
Corrigendum for submission of Certification.pdf
Download all tender documents and submit your bid