Execvutive Engineer
Executive Engineer Mechanical Division
Providing Installation and commissioning of High wall Split Window Cassette Floor mounted Split type Air Conditioning system as and when urgently required in different areas of AGMC GBP Hospital for 01 One year period
2026_CEPWD_71189_1
89_EE_DNIeT_MECH_202526
Open Tender
Electrical Works
Works
365 days
Agartala
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹47,235
3 Mar 2026
3 Mar 2026
18 Mar 2026
3 Mar 2026
18 Mar 2026
3 Mar 2026
Providing star rated (Minimum 3 star with applicable ISEER according to current industry standard) high wall split type AC machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermetically sealed compressor operating on non CFC refrigerant, pipe as supplied with AC machine, necessary plug top for IDU (With 01 year overall machine and compressor warranty) suitable for wall mounting conforming to IS 1391(Part-II) specification (Except power consumption) suitable for operation on 230 volt, 50 Hz, single phase AC supply capable of performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering having rated cooling capacity.
1.0 TR high wall split type AC machine (Minimum rated cooling capacity should not be lsss than 3000 Kcal/hr or 12000 BThu/hr or 3500 watt).
1.5 TR high wall split type AC machine (Minimum rated cooling capacity should not be lsss than 4500 Kcal/hr or 18000 BThu/hr or 5250 watt).
2.0 TR high wall split type AC machine (Minimum rated cooling capacity should not be lsss than 6000 Kcal/hr or 24000 BThu/hr or 7000 watt).
1.5 TR window/ type AC machine (Minimum rated cooling capacity should not be lsss than 4500cal/hr or 18000 Thu/hr or 5250 watt)
Providing 3 star rated (Minimum 3 star with applicabls ISEER accordlng to current industry standard) Ceiling mounted Cassette/ Floor mounted vertical Split type AC machine (Condenser & evaporator coil pipe should be made of copper) of approved make and technical specification with hermetically sealed compressor operating on non CFC refrigerant, pipe as supplied with AC machine, necessary plug top for IDU (With 01 year overall machine and compressor warranty) suitable for wall mounting conforming to IS 1391(Part-II) specification (Except power consumption suitable for operation on 420 volt, 50 Hz, single phase AC supply capable of performing a) Cooling b) Dehumidifying c) Air circulating d) Filtering having rated cooling capacity.
3.0 TR Cassette type AC machine (Minimum rated cooling capacity should not be lsss than 9000 Kcl/hr ) or 36000 BThu/h or 10500 watt).
3.65 TR floor mounted vertical Split type AC machine (Minimum rated cooling capacity should not be lsss than 10950 Kcl/hr ) or 43800 BThu/h or 12775 watt).
Standard installation, testing and commissioning of 1.0/1.5 / 2.0 TR high wall split type / window AC machine, including hole cutting, finishing etc. as per direction of the Engineer-in-charge.
Standard installation, testing and commissioning of 3.0 TR ceiling mounted cassette type AC machine, including hole cutting, finishing etc. as per direction of the Engineer-in-charge.
Standard installation, testing and commissioning of 3.65 TR floor mounted vertical Split type AC machine including hole cutting, finishing etc. as per direction of the Engineer-in-charge.
Fabrication of M.S platform for placement of condensing unit by using M.S angle of (65x65x5) or (50x50x5) mm size base plate, nuts and bolts/ universal bracket (GSS) for ODU of split type ACs including all accessories for onsite installation i/c painting, fitting, fixing, grouting by cement mixture as per direction of the Engineer-in-charge.
Fabrication of M.S platform of appropriate size, base plate, nuts and bolts/ universal bracket (GSS) for both IDU and ODU of 3.65 TR floor mounted vertical Split type ACs including all accessories for onsite installation i/c painting, fitting, fixing, grouting by cement mixture as per direction of the Engineer-in-charge.
Supply, installation of additional length of copper pipe of appropriate size of (5/8" (15.88 mm), 1/4”(6.35 mm), 3/8” (9.53 mm) and 3/4”(19.05 mm) or nearest dia. as per manufacturer design for for both suction and liquid line with insulation and necessary wiring between indoor and outdoor units for 1.5 / 2.0 TR high wall type and 3.65 TR floor mounting vertical Split type ACs.
Providing hard PVC pipe of best quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-charge.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.08 MB
DNIeT.pdf
Tender Documents • 3.04 MB
BOQ_72437.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .