Commissioner
Rajamahendravaram Municipal Corporation
Supply and Delivery of Contactors, Timers, FP MCBs and Flood Lights for Maintenance of Street Lighting of RMC.
894281
378/MCR/General/2025-26
OPEN - NCB
Similar Work
EAST GODAVARI, ANDHRA PRADESH
10 documents required · 6 mandatory · 4 optional
₹203
₹5,717
31 Jan 2026
31 Jan 2026
31 Jan 2026
Supply of 40-63A, FP MCB 10KA C/D Curve ISI Mark. Makes: Legrand-DX3 / Schneider-A9/Hager-h3/ Siemens-5SX4/ Havells STADx / Lauritz Knudsen (formerly L&T)-AU/Indo Asian-Opti pro/ HPL (Techno) /Anchor (Uno Plus) including cost and conveyance of all materials to work spot and all labour charges etc., complete as directed by the site engineer.
Supply and Delivery of Analog Timers for Operating 220v, 50hz of approved ISI Mark for operating Street Lighting On/ Off purpose including cost and conveyance of all materials to work spot and all labour charges etc., complete as directed by the site engineer.
Supply and fixing of ac operated heavy duty 230 /440 Volt power contactor conforming to IS:13947-4-1/IEC:947-4-1 having provision of mechanical interlocking, Din rail mounting type including making connections, testing etc. as required 33 to 45 Amp Make:Seimens/ABB/Schneider/ Lauritz Knudsen (formerly L&T) /C&S/HPL/Havells including cost and conveyance of all materials to work spot and all labour charges etc., complete as directed by the site engineer.
Supply and transportation of 90/100W LED Flood light Luminaire made of pressure diecast aluminum housing with powder coated, having protective toughened glass, supply Input voltage 120 - 270 V AC, P.F > 0.90, high power LEDs, with a System Efficacy >=120 lumens/watt and junction temperature < 70°C, with ingress protection IP66, Luminaire performance complies to IS 10322 (Part 5 / Sec-5), IK05, driver surge protection 4KV, In-house additional surge protection ≥ 10KV with wide/ narrow beam optics, THD<10% at 110 Volts AC, driver efficiency >90%, , CCT: 3000K - 5700K, minimum CRI>70, etc., complete with earth connection and not less than two years warranty. a) LUMINAIRE MAKE : Wipro / Philips/ GE-Venture / Crompton/ Bajaj/Greenlites / Havells /Valmont (Hypernova)/ Capart(Premium) /Halonix/ Polycab/Keselec/HPL/Jaquar/Eveready / Surya (Livia Pro) / FortuneArrt (Fin)/ Rhino(GPFL02 Series)/Orient (Sigma Plus) /Bee-lite(Endura)/Ecolink(Dura floodlight)/ Pro-Lite(BGL) b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG. including cost and conveyance of all materials to work spot and all labour charges etc., complete as directed by the site engineer.
Supply of 40-63A, FP MCB 10KA C/D Curve ISI Mark. Makes: Legrand-DX3 / Schneider-A9/Hager-h3/ Siemens-5SX4/ Havells STADx / Lauritz Knudsen (formerly L&T)-AU/Indo Asian-Opti pro/ HPL (Techno) /Anchor (Uno Plus) including cost and conveyance of all materials to work spot and all labour charges etc., complete as directed by the site engineer.
Supply and Delivery of Analog Timers for Operating 220v, 50hz of approved ISI Mark for operating Street Lighting On/ Off purpose including cost and conveyance of all materials to work spot and all labour charges etc., complete as directed by the site engineer.
Supply and fixing of ac operated heavy duty 230 /440 Volt power contactor conforming to IS:13947-4-1/IEC:947-4-1 having provision of mechanical interlocking, Din rail mounting type including making connections, testing etc. as required 33 to 45 Amp Make:Seimens/ABB/Schneider/ Lauritz Knudsen (formerly L&T) /C&S/HPL/Havells including cost and conveyance of all materials to work spot and all labour charges etc., complete as directed by the site engineer.
Supply and transportation of 90/100W LED Flood light Luminaire made of pressure diecast aluminum housing with powder coated, having protective toughened glass, supply Input voltage 120 - 270 V AC, P.F > 0.90, high power LEDs, with a System Efficacy >=120 lumens/watt and junction temperature < 70°C, with ingress protection IP66, Luminaire performance complies to IS 10322 (Part 5 / Sec-5), IK05, driver surge protection 4KV, In-house additional surge protection ≥ 10KV with wide/ narrow beam optics, THD<10% at 110 Volts AC, driver efficiency >90%, , CCT: 3000K - 5700K, minimum CRI>70, etc., complete with earth connection and not less than two years warranty. a) LUMINAIRE MAKE : Wipro / Philips/ GE-Venture / Crompton/ Bajaj/Greenlites / Havells / Valmont (Hypernova)/ Capart(Premium) /Halonix/ Polycab / Keselec / HPL / Jaquar/Eveready / Surya (Livia Pro) / FortuneArrt (Fin)/ Rhino(GPFL02 Series)/Orient (Sigma Plus) /Bee-lite (Endura) / Ecolink (Dura floodlight)/ Pro-Lite(BGL) b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG. including cost and conveyance of all materials to work spot and all labour charges etc., complete as directed by the site engineer.
Details of Maximum amount reimbursable to the Contractor.
1. Provision for GST @18%
2. Provision for NAC @0.10%
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
BOQ TS 258 NIt 378.xlsx
TENDER_DOCUMENT • 0.01 MB
Contractor Information.pdf
TENDER_DOCUMENT • 0.09 MB
DECLARATION 378.docx
TENDER_DOCUMENT • 0.02 MB
Doc.doc
TENDER_DOCUMENT • 0.65 MB
Notice ELEC 2025.doc
TENDER_DOCUMENT • 0.10 MB
PRINT TS 258 NIt 378.xls
TENDER_DOCUMENT • 0.03 MB
Download all tender documents and submit your bid