Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹29.4 CrAccepted-AOC | ₹29.4 Cr Quoted ₹29.5 Cr | 1 | Accepted-AOC Amended Lumpsum after deducting Schedule of credit of Rs 1177268.00 |
| 2 | 2₹30.6 CrRejected-Finance | ₹30.6 Cr | 2 | Rejected-Finance Other than lowest |
| 3 | 3₹31.5 CrRejected-Finance 35 B BHERU VILLAS SARDAR CLUB SCHEME AIR FORCE JODHPUR 342 011 RAJASTHAN | JODHPUR | JODHPUR | RAJASTHAN | 342011 | ₹31.5 Cr | 3 | Rejected-Finance Other than lowest |
| 4 | 4₹31.5 CrRejected-Finance | ₹31.5 Cr | 4 | Rejected-Finance Other than lowest |
| 5 | 5₹34.4 CrRejected-Finance | ₹34.4 Cr | 5 | Rejected-Finance Other than lowest |
Tender Value
₹32.6 Cr
EMD Value
₹15 L
Closing Date
14 Sept 2021, 6:00 pmClosed
CHIEF ENGINEER (NAVY) VISAKHAPATNAM
Chief Engineer Navy Station Road Visakhapatnam 04
DEMOLITION/RECONSTRUCTION MARRIED ACCOMMODATION (For 112 NUMBERS OF SAILORS) AT SVN COLONY VISAKHAPATNAM
2021_MES_463982_1
85396
Open Tender
Civil Works
1080 days
Visakhapatnam
As per NIT
7 documents required · 7 mandatory
₹3,000
Garrison Engineer (P)(N) Visakhapatnam
₹15 L
Yes
7 Oct 2021
30 Jul 2021
16 Sept 2021
30 Jul 2021
14 Sept 2021
30 Aug 2021
30 Jul 2021 - 26 Aug 2021
Amount
NOTE :- Schedule "A" Part I to be quoted by the Bidder. Bidders shall insert their lumpsum amount in Green coloured field under col-7 only
Construction of Married accn for POs/LDG below sailors in RCC Framed Structure (G+9 storeyed) with pile foundations complete all as specified and as shown on drawings and as directed.
Blank
NOTE: Schedule "A" Part II to Part XV are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under col-07 only
Lumpsum price worked out by the contractor for " Site Clearance / Area Development / Earthwork/ Excavation", as listed in Schedule "A" Part – II on Serial Page No. 35.
Lumpsum price worked out by the contractor for " Pile Foundation", as listed in Schedule "A" Part – III on Serial Page No. 36.
Lumpsum price worked out by the contractor for "Internal Electrification", as listed in Schedule "A" Part – IV on Serial Page No. 38.
Lumpsum price worked out by the contractor for "Internal Water Supply", as listed in Schedule "A" Part – V on Serial Page No.40.
Lumpsum price worked out by the contractor for "Sewage Disposal", as listed in Schedule "A" Part – VI on Serial Page No. 42[R].
Lumpsum price worked out by the contractor for "External Water Supply", as listed in Schedule "A" Part – VII on Serial Page No. 43.
Lumpsum price worked out by the contractor for "External Electrification", as listed in Schedule "A" Part – VIII on Serial Page No. 46[R].
Lumpsum price worked out by the contractor for "ROADS /PATH/HARD STANDING/CULVERT", as listed in Schedule "A" Part – IX on Serial Page No. 48.
Lumpsum price worked out by the contractor for "Area Drainage", as listed in Schedule "A" Part – X on Serial Page No. 49.
Lumpsum price worked out by the contractor for "Rain Water Harvesting", as listed in Schedule "A" Part – XI on Serial Page No. 50.
Lumpsum price worked out by the contractor for "LIGHTENING PROTECTION", as listed in Schedule "A" Part – XII on Serial Page No. 51.
Lumpsum price worked out by the contractor for "FIRE ALARAM and DETECTION", as listed in Schedule "A" Part – XIII on Serial Page No. 52.
Lumpsum price worked out by the contractor for "FIRE FIGHTING SYSTEM ", as listed in Schedule "A" Part – XIV on Serial Page No. 54.
Lumpsum price worked out by the contractor for "DISMANTLING/ DEMOLITION", as listed in Schedule "A" Part – XV on Serial Page No. 56.
Schedule "A" Part - XVI [Miscellaneous Items]
PILE FOUNDATION
Boring for bored cast-in-situ piles 600mm dia in any strata except SDR/hard rock and getting out and disposal of spoil out side MD land using Hydraulic system of boring method, complete all as specified and directed.
Boring for bored cast-in-situ piles 600mm dia in SDR/ hard rock and getting out and disposal of spoil out side MD land using hydraulic system of boaring method complete all as specified and directed.
Carrying out initial load test on 600mm dia pile as per IS 2911 Part IV,complete all as specified and directed.
Carrying out routine load test on 600mm dia pile as per IS 2911 Part IV,complete all as specified and directed.
Carrying out lateral load test on cast in situ piles 600 mm dia piles as specified in IS and directed by Engr - in- Charge.
Carrying out pull out test on cast on situ piles 600 mm dia pile as per specified in IS ,complete all as specified and directed by Engr - in- charge.
Carrying out low strain integrity test on bored cast in situ piles including analysing the result as per ASTM D 5882 and as directed by Engr - in- Charge.
Chipping out pile up to cut off level including disposal up to a distance outside MD land all as specified and directed.
INTERNAL WATER SUPPLY
S & F Angle stop valve, chromium plated , fancy type , high pressure screwed and fixed suitable for 20mm PP-R pipe complete.
S&F Bib taps two way, fancy type CP screwed down for size of 15 mm dia
S&F health faucet chromium plated , fancy type with steel flexible complete of size of 15 mm dia
INTERNAL ELECTRIFICATION
Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including medium duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box factory made of MS Sheet of suitable size and required module plate top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for one light point controlled by one switch complete all as specified and as directed.
Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including medium duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box factory made of MS Sheet of suitable size and required module top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for one bell point controlled by one bell push complete all as specified and as directed.
Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including medium duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box factory made of MS Sheet of suitable size and required module top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for one fan point controlled by one point complete all as specified and as directed.
Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including medium duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box factory made of MS Sheet of suitable size and required module top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for one three pin socket outlet 6 Amp socket on independent board complete all as specified and as directed.
Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including medium duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box factory made of MS Sheet of suitable size and required module top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for one three pin socket outlet 6 Amp socket on same board complete all as specified and as directed.
Point Wiring complete with 1100 Volts, FRLS Grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including medium duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box factory made of MS Sheet of suitable size and required module top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for one three pin socket outlet 15 Amp socket on independent board complete all as specified and as directed.
Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including medium duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box factory made of MS Sheet of suitable size and required module top cover for fixing switches, fittings, regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for one light point controlled by two number two way switch complete all as specified and as directed.
LED adore lamp for AC 240Volt supply, including B22 type bulb holder,CDS five star, 10 watts of five star rated complete all as specified and as directed.
Energy efficient LED tube light fitting suitable for mirror light with tube 5 watts or nearest size, 240V, 50Hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sqmm 3 core flexible copper conductor cable complete all as specified and directed.
Supply and fixing Energy efficient LED tube light fitting with tube 9/10 watts or nearest size ,240V, 50hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed
Energy efficient LED tube light fitting with tube 20 watts or nearest size, 240V, 50Hz surface mounted, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack of complete with mounting bracket etc including connecting up with 1.0 sq mm 3 core flexible copper conductor cable complete all as specified and directed.
LED Security light fitting with tube 30W new generation energy saving & environmental friendly long lifemade up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening seperate driver compartment with IP66 protection pre wired with 1.0 Sq mm copper conductor cable upto connector including 1.5 m long GI tubing light grade of 32mm dia bend to shape for fixing on wall/pole with suitable MS brackets nuts and bolts etc. compelte all as specified and as directred.
Ceiling fans AC single phase 230V of size 1200mm sweep, copper wound with complete set of fixtures such as canopy, down rod etc , 5 star rating, metallic body complete with and inclusive of making necessary electric connections from ceiling rose to fan tthrough twin core flexible wire all as specified and directed.
S&F Exhaust fan 250 mm sweep or nearest size, plastic body (Heavy duty), complete with louvers suitable for operation on 230 V AC, 50 Hz AC supply fixed on wall making opening,fixing and making good the distrubered surfaces etc. complete with and inclussive of making necessary electric connection from ceiling rose to fan through twin core flexible wire all as spcified and as directed.
S&F Exhaust fan 300 mm sweep, metallic body (Heavy duty),900 RPM, complete with louvers suitable for operation on 240 V AC, 50 Hz AC supply fixed on wall including making of neccessary opening, fixing and making good the disturbed surfaces etc complete with and inclussive of making necessary electric connection from ceiling rose to fan through twin core flexible wire all as specified and as directed.
S&F Sub main wiring with 4 runs of single core 16 Sq.mm Single Core, FRLS, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, for phase and neutral duly colour coded drawing through and including medium duty PVC Conduit, 32 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. including one run of 16 Sq.mm, Single Core, FRLS PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified. (Bus bar trunk/MCCB to VTPN DB of each floor). Note: 4 runs of 16 Sq.mm, 1 runs of 16 Sq.mm & one run of 32mm dia PVC Conduit will be measured as one unit
S&F Sub main wiring with 2 runs of single core 6 Sq.mm Single Core, FRLS, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, for phase and neutral duly colour coded drawing through and including medium duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. including One run of 6 Sq.mm, Single Core, FRLS PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified. Note: 2 runs of 6 Sq.mm, 1 runs of 6 Sq.mm & one run of 20mm dia PVC Conduit will be measured as one unit
Sub main wiring with 2 runs of single core 2.5 Sq.mm Single Core, FRLS, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, for phase and neutral duly colour coded drawing through and including medium duty PVC Conduit, 20 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. including One run of 2.5 Sq.mm, Single Core, FRLS PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified. Note: 2 runs of 2.5 Sq.mm, 1 runs of 2.5 Sq.mm & one run of 20mm dia PVC Conduit will be measured as one unit
Supply and fixing concealed in wall Vertical MCB DB double door type, TPN 8 way 415V, 50Hz , IP 43 protection with 200A rated bus bar , including provision for fixing MCCB FP 63 amp as incommer and outgoing circuits MCB SP/TP complete, fill empty way with blanking plates complete all as specefied and directed. Note:- MCCB and MCBs shall be measured and paid seperately.
Supply and fixing single phase electronic Energy meter tamper proof with LED display, 240 volt , 50Hz AC supply, 10 to 30 amps capacity complete all as specified and as directed.
Supply and fixing prefabricated meter box made out of 2mm thick CRCA sheet duly powder coated of approx size 50cm x 60 cm to accommodate 6 Nos single phase energy meter , front portion of the meter box to be provided with six opening to take the reading of energy meter and the six slit is to be covered/fixed with glass, necessary sunmica sheet of suitable size to be provided inside the meter box to fix the energy meter, with locking arrangements complete including sealing of energy meter all as directed and as specified. Note: Energy meter shall be measured and paid seperately.
Supply and fixing telephone socket with and inclussive of prefabricated terminal box and switch plate for fixing telephone socket all as specified and directed.
Supply and fixing TV socket with and inclussive of prefabricated terminal box and switch plate for fixing TV socket all as specified and directed.
Supply and fixing/drawing PVC insulated telephone cable one pair on existing PVC conduits concealed to wall, of Havells make basic code No "WHTTATEL1P40 or equivalent make. Note : PVC conduit shall be measured seperately, both end of the telephone cable to be taged/marked in colour code sleeves of each qtr number.
Supply and fixing/drawing PVC insulated telephone cable three pair on existing PVC conduits concealed to wall, of Havells make basic code No "WHTTATEL3P40, or equivalent make. Note : PVC conduit shall be measured seperately, both end of the telephone cable to be taged/marked in colour code sleeves at ground floor and at each floor junction box.
Supply and fixing PVC junction box of approx size 10cm x 15 cm rectangular type concealed to wall to accommodate PVC connector of six way for telephone cable on each floor.(for three DUs)
Supply and fixing junction boxes of FRP body of size 15 cm x 10 cm with and including PVC connector three way for telephone cable at each floor
Supply and fixing junction boxes of FRP body of aprox size 50 cm x 30 cm with and including PVC connector 56 way for telephone cable at ground floor floor
EXTERNAL WATER SUPPLY
Material and Laboure for laying of Ductile pipe with spigot and socket end centrifugally cast(spun) class K-9 of 100 mm dia pipe conforming to IS-8329 including provision of specials, such as tees, elbows,bends reducers, taper pieces, including testing and commissioning all as specified and as directed.
Construction of Valve Chamber of size 750 X 750 X 750 mm , with 50mm thick PCC 1:5:10, Type E2, using 40mm graded aggregate for foundation, 200 mm thick Brickwork with old size Fly Ash Bricks in Cement Mortar 1:6, 100 mm thick PCC, 1:3:6, Type C1, using 20mm graded aggregate Coping, rendering in CM 1:4, 15 mm thick internally and externally up to 50mm below GL including provision of Mild Steel Sheet Cover 3 mm thick with 40 X 40 X 6 mm size Angle Iron frame work embedded in concrete with suitable hinges and locking arrangements including two coat of synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary earth work excavation in any type of soil etc., removal of surplus soil off the premises complete all as specified.
Cutting existing DI pipe line for alterations or additions necessarily done in position without taking down and inserting T of 100 x 100 x 100 mm and Tee for tapping all as specified and directed.
Supply, install, testing and commissioning of centrigugal pump set with minimum ratings not less than 20 HP , 70 Mtr Head , 10 LPS with delivery size of 80 mm bore, with 4 pole, 415 Volts, 50 Hz, AC 3 Phase supply, electric driven, inclusive of air valve at delivery, pressure guage,star delta starter for pumps along with cabling by XLPE Copper cables from starter to Pump set with cable tray and PCC foundation. all as specified and directed .
Supply and fix flanged end lift type Foot valve 100 mm dia with brass strainer, suitable flanges, nuts, bolts, gaskets complete all as specified and directed.
Supply and fix sheet metal encloser with provision of fixing incoming and out going cables with bus bar and cable connection to tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 100 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following all as specified and as directed. (For Fresh Water Pumps) Incomming:- (a) MCCB 63 Amps,25 KA - 01 Nos Outgoing:- (a) MCB 32 Amp,16 KA TP - 03 Nos(for two pumps + 01 Spare). (b) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases-03 Nos. (c) DOL starter of capacity 20 HP, 3 Phase, 4 wire - 2 Nos.
ROADS /PATH/HARD STANDING/CULVERT
Granular sub Base (GSB) with grading V of 150mm thick Compacted thickness (laid in two layers of 75mm each, Compacted seperately) confirming to grading as specified, spread, rolled and consolidated to required gradient asnd camber complete using necessary mechanical paver/ Grader and vibratory soil compacter of Capacity 8-10 ton all as specified and as directed. (a) Pavement shall be made for solid quantity arrived after consolidation. (b) Compaction of granual sub base filling shall be carried out under Optimum moisture condition to achieve 98.50 modified density. (c) Curing shall be carried out as per IRC recommendations. (d) Before execution of this item the approved material obtained from outside MD land shall be tested/ checked for suitability to use.
(e) The lead/ Royalty involved is to be ascertained by the contractor before quoting his tender and no extra payment/ Adjustment for increased in lead or Rate of Royalty due to whatever reason shall be admissible on his account. (f) Contractor shall use Vibratory earth compactor inlieu of Power roller to achieve 98.00% MDD at OMC without any extra cost and the method of compaction to be adopted as per recommendation of agency reporting MDD at OMC. (g) GSB shall be as per MORTH specification as detailed in Perticular specification.
Wet mix Mecadam of 250mm thick (Compacted thickness) laid in three equal layers compacted seperately with Coarse aggregate of specified grade spred rolled and consolidated to required gradient and camber complete using mechanical paver/ Grader and Pandom Vibrator of capacity of minimum 8-10 Tons at OMC to achieve atleast 98% MDD determained using modified Proctor density determination method as per IS code on prepared GSB surface complete all as specified and as directed. Note : 1. The rate quoted shall be for 250mm compacted thickness. 2. Each layer shall be rolled seperately.
M & L for Painting lines, dashes, arrows, letters, etc. on road surface with hot applied retro reflective thermoplastic paint confirming to MORTH (Clause. 803.40) all as specified with 8% glass beads using special applicator machine with heating arrangement upto 160 Degress C, including cleaning and drying the road surfaces to ensure dust,oil,grease and moisture free surface beforeapplying paint complete all as specified as directed.
EXTERNAL ELECTRIFICATION
XLPE insulated and screened insulated, FRLS armoured and PVC bedded underground HT cable, ISI marked with aluminium stranded conductor 11000 Volt grade (heavy duty) of size 3 Core, 120 Sq.mm cross section conforming to IS-7098 (Part-II) laid in trenches, fixed to walls or passing through pipes and connecting up complete all as specified and directed.
XLPE insulated and PVC sheathed, FRLS armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 185 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc complete.
XLPE insulated and PVC sheathed, FRLS armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 150 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc complete.
XLPE insulated and PVC sheathed, FRLS armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3½ Core, 120 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc complete.
XLPE insulated and PVC sheathed, FRLS armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 4 Core, 50 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc complete.
XLPE insulated and PVC sheathed, FRLS armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 4 Core, 16 Sq.mm cross section suitable for earthed system, laying in trenches / duct / fixed to poles / drawn through pipes / sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc complete.
Supply, install, testing and commissioning outdoor type SF6 insulated compact R.M.U. extandable on both sides with rated voltage 11 KV rated current 630 A, short circuit breaking current 16 KA and making capacity 40 KA ,fully arc proof metal enclosed, free standing, floor mounting, flush fronted type consists of manually operated non draw out type SF6 filled load break switch-01 No (Incomers) and 2 Nos outgoing SF6 filled load break switches with integrated relays and related CTs as specified below, cable switch module and an interlocking mechanism with the earthing switch all as specified and directed. Degree of protection shall be per manufacturer specifications. (a) Fixed type voltage indicators and electronic short circuit indicators for simple fault indication b) Resin cast CT with ratio 75/1-1 with 15VA burden class1 for metering and class 5 P10 for protection-Set of three c) Resin cast potential transformers with ratio 11KV/1.732, 110V/1.732, 200 VA class1 with HT fuses mounted on with drawable rack d)Self powered microprocessor controlled numeric relay comprising of three over current , one earth fault protection relay with high set for both phase & earth and with fault memory, universal auxliary supply Model No.IRI1- WD of C&S make / Model No MC-61A of L&T /SIEMENS/ABB/AREVA
Suppy, fixing and testing of LT Panel board (Feeder Pillar Box) made out of CRCA sheet 3.15 mm thick of suitable size but not less than 1.2x1.0x0.5m size outdoor type FPB made out of CRCA sheet 3.15 mm thick outdoor Pedestal type of totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V, 800 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following: (Main LT FPB)
INCOMING: - a) MCCB 4 pole, 415 V, 50Hz 500 A capactiy 35kA microprocesser based adjustable type - 1 No. OUTGOING: - a) Adjustable type MCCB 4 Pole 160 Amp 50 Hz 415 V with rupturing capacity 25 KA-04 Nos (Bldg -02, APFC - 01 & 01 No spare), b) MCCB AC 3 Phase 415 V, 50Hz 4 pole 125 A capactiy 25kA with adjustable type thermal and magnetic setting relays - 03 Nos ( AMF Panel - 01,APFC - 01 and 01 No spare) c) Intelligent Panel meter to measure voltage, current, frequency, power factor, etc with all connected CTs d) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases
Supply fixing and testing of LT Panel board (Feeder Pillar Box) made out of CRCA sheet 3.15 mm thick of suitable size but not less than 1.2x1.0x0.5m size outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 200A capacity complete with powder coating, necessary internal electric connection as required and provision of the following: INCOMING:- a) MCCB AC 3 Phase 415 V, 50Hz 4 pole 125 A capactiy 25 kA with adjustable type thermal and magnetic setting relays - 01 Nos OUTGOING: - a) MCCB AC 3 Phase 415 V, 50Hz 4 pole 63 A capactiy 25kA with adjustable type thermal and magnetic setting relays - 03 Nos (Lift-02 No, Spare- 01 No)., b) MCCB AC 3 Phase 415 V, 50Hz 4 pole 32 A capactiy 25kA with adjustable type thermal and magnetic setting relays - 04 Nos (for Street light-01 No, Boster Pump-02 Nos ,spare-01No).,c) Intelligent Panel meter to measure voltage, current, frequency, power factor, etc with all connected CTs ., d) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases
Supply and Installation Supply, installation, testing and commisioning of Bus bar trunking system for the complete bldg power supply duly insulated three phase of rating 250 Amps, 25 KA 415 Volts aluminium conductor galvanised GI enclosure 0.8 mm thick (Non painted) and lightning bus trunking with galvanised steel enclosure (0.45mm thick), non painted through service shaft including end feed unit with MCCB 250 A 25 KA 4P with rotary handle, termination links of bldg comprising of followings:
Supply and fix Straight feeder of Busbar trunking system as specified and directed.
Supply and fixing of Flange end of Busbar trunking system as specified and directed.
Supply and fix End Cover - 01 Nos(for main riser) of Busbar trunking system as specified and directed.
Supply and fix Brackets of Busbar trunking system as specified and directed.
Supply and fix Springs Hangers of Busbar trunking system as specified and directed.
Supply and fix Fire barrier complete for BBT of Busbar trunking system as specified and directed.
Supply and fix Addaptor box of Busbar trunking system as specified and directed.
Supply and fix Copper braided flexibles complete for BBT of Busbar trunking system as specified and directed.
Supply and fixing of External GI strip 32 x 6 mm of Busbar trunking system as specified and directed.
Supply and fix 63A 4P lightning trunking of Busbar trunking system as specified and directed.
Supply and fix Flexible elbow as required at site of Busbar trunking system as specified and directed.
Supply and fix Horizontal elbow as required.of Busbar trunking system as specified and directed.
Supply and fix MS 100A Centre feed Unit IP 55 of Busbar trunking system as specified and directed.
Supply and fix 63 A TAP OFF Box Prov for MCB of Busbar trunking system as specified and directed.
Supply and fix End cover for 63 A feeder of Busbar trunking system as specified and directed.
Supply and fix MS Sleeve IP 55-10 Nos of Busbar trunking system as specified and directed.
Supply and fix MS Plug point Gasket IP 55-10 Nos of Busbar trunking system as specified and directed.
Supply and fix suspenssion Bracket of Busbar trunking system as specified and directed.
Supply and fix 125 A tap off box with,MCCB 63A 4P, 16 KA to Busbar trunking system as specified and directed.
Supply and fix 250 A 25 KA 4P MCCB to Busbar trunking system as specified and directed.
Supply and fix sheet metal encloser ,provision of fixing incoming and out going cables with bus bar for cable connection alluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 100 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following:(Block Panel) all as specified and as directed. (For lift machine room) Incomming:- (a) MCCB 63 Amps,25 KA - 01 Nos Outgoing:- (a) MCB 32 Amp,16 KA TP - 03 Nos(for two lift panel + 01 Spare). (b) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases
Supply & Fix Integral LED street light Luminaire 40 Watts, comprising of epoxy powder coated, Pressure die cast aluminium housing enclosed with glass cover in frame, with suitable size of bracket, nut and bolts, PVC insulated three core flexible cable of suitable size and length duly connected to light fitting complete including installation and testing all as specified and directed.
Supply & Fix Loop in loop out box of FRP made with IP 65 protection of thermoplasic circuit breaker boxes with metric knockouts for cable entry and exit, Combi climate Cable Glands of IP 66/ IP 67 for cable entry and Grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10 kA, C Curve Overload and Short Circuit protection, terminals as bus terminals for cable with necessary fixing arrangemets and with cable glands, etc all as specified and directed.
Earthing complete with Galvanised iron earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 32 X 6 mm GI earth strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m in length from earth plate, Earth Plate Electrode surrounded by 150 mm thick packed layers of Charcoal and Rock Salt filled in alternate layers, connected to the plate by means of brass Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part - I, connected to panel / DB including testing on completion including main earthing, Charcoal, Rock Salt, PCC chamber [1:3:6, Type C1] with RCC cover of 1:2:4 type B1 , MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified.
Earthing complete with copper plate electrode 60 cm X 60 cm X 3 mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level)with top edge of the plate not less than 1.5 metres below normal groundlevel, connected to copper strip of 20mm x 3mm by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No-5 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipelight grade for watering pipe and 32 mm bore GI light grade for earth lead protection pipe connected upto DBs, and suitable CI top cover with handle, funnel, strainer,charcoal, salt and testing on completion all as specified and directed. Note- Rate quoted deemed to be include excavation and earth work in any type of soil with PCC workcomplete all as specefied and directed. (item caters for Internal Elec)
M & L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
Supply and fix time switches 415 V ,50 Hz of 20 Amp rating with contactor Fitted inside steel enclosure all as specified and as directed
M & L for masonry plat form for trasformer of size 1.5x1.5x1.2 Mtr, with Ramp having slope on one side of 45 degree from horizontal upto ground level with RR masonary in CM 1:6, in foundation base 75mm thick PCC 1:4:8 type D2 with 40 mm graded aggregate, and 100mm thick PCC 1:2:4 type B1 with 20 mm graded aggregate at top of the platform, 20mm thick plastering in CM 1:6 externally upto 50mm below GL and three coats of white wash including Earth work excavation complete and specified and directed by Engineer-in-Charge.
Supply and fix HT Cable route indicator cast iron 150mm dia, 6mm thick plate with arrow for indicating direction 3mm embossed letters with 2No of holes and mounting on angle iron of 50x50x5mm of 1.0 M height with painting including with PCC, Earth work excavation & painting complete and specified and directed by Engineer-in-Charge.
(A) Alternator :- Standard design alternator rated at 100 KVA net output at site after considering de-rating as per site conditions at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of +/- 1% at rated voltage from no load to full load. The alternator shall be conforming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation with in +/- 1% tolerance. The alternator will be suitable for tropical climate and shall generally conform to BS - 2613/5000/ IS – 4722., i) Insualation class - 'H‘., ii) Temparature rise Class - 'H‘ iii) Excitation : Self Excited iv) Regulation performance: The voltage is kept constant with +/- 1%, manual voltage adjustment within +/- 5% v) Frequency regulation +/- 1%.,
(B) Diesel Engine: - Adequate capacity of Diesel engine as accosted by the accepting officer basing on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:- i)Fly wheel with housing., ii) Cooling system :- Moulded radiator with fan & belts., iii) Cooling Water pump : - Centrifugal type belt driven., iv) Exhaust System :- Exhaust System complete with exhaust piping of 150mm dia with MS pipe light grade upto & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure.Exhaust gas turbo charger type. Exhaust manifold
Silencer : Residual type Bellows., iv) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed /frequency regulation, Fuel filters, Fuel hoses. v) Lub oil System : -Lubricating oil filter ,Lubricating oil pump., vi) Air Intake System : Air intake Manifold Air cleaner dry type vii) Governor :- Electronic Governor viii) Starting System :- Electric Self starter with maintenance free battery including battery charging alternator., ix) Batteries :- Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and Starter gear ring Start and stop push button, Ignition key / Switch
Handling and operation : Salient features of accessories shall be as under: Radiator with blower fan., Corrosion inhibitor coolant Paper element filters for fuel, lub oil and by pass Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel., x) Generator Monitoring Panel : - Comprising of all standard items as mentioned under this schedule or asper standard practice iginiton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, water/coolent temparature indicator, Battary volt display. xi) Safety Controls : - Engine low lube oil pressure high water temparature and over speeding of engine., xii) Coupling arrangement : - Flexible coupling, fly wheel to suit flexible coupling., xiii) Accessories :- AVM Pads built in enclosure and for entire unit on platform. xiv) Base Frame : - Should be provided as OEM norms. xv) Fuel Tank :- Additional Fuel Tank of capcaity to suit Daily service fuel tank made out of 3mm thick (10G) HR sheet top and bottom with caliberated level indicating arrangement, stop cock, drain plug, fuel pump of suitable capacity complete on a common base out side the accoustic enclosure., xvi) MS pipe line to and from the fuel tank to the DG Set.
D) Accoustic Enclosure:- Manufactured by OEM suitable for 100 KVA DG Set (i) NAL approved as per CPCB (ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board., (iii) The generating set battaries and control panel should be inside the enclosure. (iv) Blank. (v) Construction Details/specification are as follows: a) Outer body :- CRCA Sheet of 1.6mm thick b) Doors :- CRCA sheet of 1.6 mm thick c) Sound Insulation :- As per OEM Norms., vi) The accoustic should be composite in construction and fully assembled integral unit., vii) The batteries should be placed inside the enclosure beside the DG Set on a suitable insulated plat form viii) The fuel tank is to be located inside the enclosure., ix) The DG Set should be provided with external Emergency stop push button x) The enclosure should be suitably illuminated by LED Lamp fittings.
xi) The noise level should be 75 dba at 1m under free field conditions., xii) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen set Green. The base frame should be painted with epoxy based black shade. E) The coated rate includes excavation, removing of soft soil and PCC, Cement Concrete foundation, filling and mass concrete type B2 (1:2:4) using 40 mm graded aggregate of size not less than 4.6 x 2. 4 x 0.8 m for placing of DG Set complete all as specified and directed.
f) Aluminium chequered plate (3 mm thick) as flooring joint in chequered palte should not more than one and top covering with granite flooring complete. g) Non stop button / independent operation. h) Over load warning indicator both audio and visual type with tripping sustem having relays etc (overload protectin / tripping system). j) Front landing door of stainless steel mirror finish operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds. k) Car size shall be conformity with IS-3534-1976 and body to be stainless steel of 16 gauge mirror finish with stainless steel hand rail 38 mm hairline finish. l) Set of three in number limit swithces at the bottom and top most position of lift hoist ways as specified in IS. m) Mirror of 4 mm thickness of suitable size as specified. n) Opening with mirror of 5mm thick 200 x 800 mm size in all the doors (Car/Landing doors). o) Specification plate with complete details . p) Contineuos earthing for machine and equipments. q) Steel wire rope of adequate sixze as per relevant IS and as per manufacturerer specifications.
r) Other standard fixtures and fitting like guide rails, sheaves, counter weights with guards, buffers, gear unit breakes, control panel, locks, governor, car operational panel, power, control and trailing cables complete.s) Full length display indicator panle. t) Main drives and control shall be of latest, high effective and low power consumption. u) Suitable phase reversal relay shall be provided on the controller to protect lift / equipment against phase reversal, phase failure and low voltage. v) Stainless steel fron opend landing door with small opening for vision of size 200 mm x 800 mm with toughended galss not less than 8mm thick. Make of Toughened Glass : Safgex / Saint Gobain Glass / Modiguard float glass / kesar / Asshi Indian / Atul Tuf / Hindustan pilkington glass works / Trivenin float glass. w) Intercome be connected with nearest security post.
(a) Fire man switch., (b) Automatic rescue devide (ARD) during power failure including manual operation provision with suitable capacity of battery designed for funnign the lift with full load., c) Battery operated emergency light (Led ceiling fitting), alarm (Speaker for emergency alarm system with calling/ announcement/alarm, receivers at ground floor and lift machine room to be fixed) and stop button in car with rechargeable arrangement for battery., d) Four sleek circular 5 Watt LED light fitting in false ceiling . e) Two sleek circular PVC low noise fan in false ceiling. Make for(c) & (d) : Philips / Bajaj / Havells / Crompton Greaves.
f) Aluminium chequered plate (3 mm thick) as flooring joint in chequered palte should not more than one and top covering with granite flooring complete. g) Non stop button / independent operation. h) Over load warning indicator both audio and visual type with tripping sustem having relays etc (overload protectin / tripping system). j) Front landing door of stainless steel mirror finish operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds. k) Car size shall be conformity with IS-3534-1976 and body to be stainless steel of 16 gauge mirror finish with stainless steel hand rail 38 mm hairline finish. l) Set of three in number limit swithces at the bottom and top most position of lift hoist ways as specified in IS. m) Mirror of 4 mm thickness of suitable size as specified. n) Opening with mirror of 5mm thick 200 x 800 mm size in all the doors (Car/Landing doors). o) Specification plate with complete details .
p) Contineuos earthing for machine and and equipment earth strip upto body of equipment as per IS specification. q) Steel wire rope of adequate sixze as per relevant IS and as per manufacturerer specifications. r) Other standard fixtures and fitting like guide rails, sheaves, counter weights with guards, buffers, gear unit breakes, control panel, locks, governor, car operational panel, power, control and trailing cables complete.s) Full length display indicator panle. t) Main drives and control shall be of latest, high effective and low power consumption. u) Suitable phase reversal relay shall be provided on the controller to protect lift / equipment against phase reversal, phase failure and low voltage. v) Stainless steel fron opend landing door with small opening for vision of size 200 mm x 800 mm with toughended galss not less than 8mm thick. Make of Toughened Glass : Safgex / Saint Gobain Glass / Modiguard float glass / kesar / Asshi Indian / Atul Tuf / Hindustan pilkington glass works / Trivenin float glass. w) Intercome be connected with nearest security post.
Note for LIFTS :- Cost of comprehensive/periodical maintenance of Lifts including spare parts during defect liability period is deemed to be included in the rate quoted for the lift item under Phase- II
AVIATION LIGHT
Cable PVC insulated armoured PVC sheathed LT 1100 V grade with copper conductor of size 3 core 2.5 Sqmm multi stranded conductor laid in ground fixed to wall roof etc with suitable clamps spacers bolts, nuts etc. Complete all as specified and directed.
Aviation obstruction light LED type filament-less bulb with 10 Watt bulb complete including standard fixing arrangements complete all as specified and directed.
Time switches 250V single phase of 20 Amps rating with contactor fitted inside steel enclosure complete all as specified and directed.
FIRE FIGHTING SYSTEM, FIRE ALARM AND DETECTION
Cutting existing pipe any size/type not less than 150 mm dia for alter for alterations or additions necessarily done in position without taking down and inserting T of 150 x 150 x 100 mm and Tee of 100 x 100 x 100 mm for tapping all as specified and directed.
GEYSER
Supply, installation, testing and commissioning of geyser electric driven (single phase), PVC body having capacity of 15 litre of 5 star rated with flexible stainless steel branded water pipe 450 mm long along with nuts on both ends.and including all acessories complete all as specified and directed.
ARBORICULTURE
Supply & Planting carpet Grass by piece turfing including preparation of ground upto 30 cm deep and filling soft soil, cow dung and watering etc complete all as specified and directed. Note: Loose soil and cow dung shall be measured and paid separately UNDER SUPPLY ONLY.
Supply only approved loose soil of best quality for plantation.
Supply only approved manure (Cow dung) of best quality for plantation.
Supply only approved vermi compost of best quality.
Supply and plantation of Mango (height of plant not less than 2.0m above ground level) incl preparation of ground up to 560cm deep and filling of good earth, cow dung vermi compost and watering etc complete all as directed by the Engineer-in-charge.
Supply and plantation of Guava of height not less than 1.50 m above ground level) incl preparation of ground up to 560cm deep and filling of good earth, cow dung vermi compost and watering etc complete all as directed by the Engineer-in-charge.
Supply and plantation of Naseberry of height not less than 1.50 m above ground level) incl preparation of ground up to 560cm deep and filling of good earth, cow dung vermi compost and watering etc complete all as directed by the Engineer-in-charge.
MAINTENANCE OF ARBORICULTURE
Material and labour for maintenance including watering and fertilization of all the grass/plants/trees by weeding housing saucer melding once in every 15 days, planting new plants/grass spices and height with out any extra cost to the department for period of maintenance period of two years from the completion date of project complete all as specified and directed.
COMPREHENSIVE MAINTENANCE OF LIFTS
Comprehensive maintenance of Electrically Operated 08 passenger lifts(544 Kgs) to serve G+9 upper floors all as mentioned vide SI No. 123 of Sch "A" Part - XVI during 1st year after expiry of defects liability period all as specified and directed
Comprehensive maintenance of Electrically Operated 13 passenger lifts(884 Kgs) to serve G+9 upper floors all as mentioned vide SI No. 126 of Sch "A" Part - XVI during 1st year after expiry of defects liability period all as specified and directed
Comprehensive maintenance of Electrically Operated 08 passenger lifts(544 Kgs) to serve G+9 upper floors all as mentioned vide SI No. 123 of Sch "A" Part - XVI during 2nd year after expiry of defects liability period all as specified and directed
Comprehensive maintenance of Electrically Operated 13 passenger lifts(884 Kgs) to serve G+9 upper floors all as mentioned vide SI No. 126 of Sch "A" Part - XVI during 2nd year after expiry of defects liability period all as specified and directed
Comprehensive maintenance of Electrically Operated 08 passenger lifts(544 Kgs) to serve G+9 upper floors all as mentioned vide SI No. 123 of Sch "A" Part - XVI during 3rd year after expiry of defects liability period all as specified and directed
Comprehensive maintenance of Electrically Operated 13 passenger lifts(884 Kgs) to serve G+9 upper floors all as mentioned vide SI No. 126 of Sch "A" Part - XVI during 3rd year after expiry of defects liability period all as specified and directed
(vi) Breakdown maintenance consists of attending to the faults that may occur and carrying out necessary repairs to electrical, control circuits and mechanical components including materials & labour for all minor & major spare parts and consumables of the lift that may occur during the operation. (vii) Fortnightly, quarterly maintenance registers shall be maintained and signed by the site engineer and contractor.
Material and Labour for 150mm Dia Double wall corrugated hdpe pipes, laid in trenches or in floors, jointed as per manufacturers direction complete all as specified and as directed. etc complete all as directed by the Engineer-in-charge.
Komal Buildcon Pvt. Ltd.
RAGHUSONS INFRA ENGINEERING PVT. LTD
SHRI GURMUKHDAS CONTRACTORS PVT. LTD.
MANGLA AMIT BUILDERS PVT LTD
DHARIWAL TRADERS PRIVATE LIMITED
Rabina Enterprises Pvt Ltd
CH.VEERARAGHAVULU CONSTRUCTION PVT LTD
SOOD ASSOCIATES PVT LTD
M/s Madan Lal Bansal and Co. Contractors Pvt. Ltd.
Som Projects Pvt Ltd
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid