Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
29 Dec 2025, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Revenue
Above/Below/Par
WORKS 2
14 conditions · 3 needing a document upload
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or "V" whichever is less; Where V=Advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Electrical contractor license: - The contractor should have valid electrical contractor license issued by government and submit along with tender document. If valid electrical contractor license is not submitted along with tender document, then offer will be summarily rejected.
Technical Eligibility Criteria: (a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender. The Definition of similar nature in this tender means "Any Electrical work related to HT/LT installations". (Authority: PCEE / NWR / JP letter No EL/50/0/SNW/Vol.I Dtd. 08.01.2016).
4 conditions · 2 needing a document upload
Bidder / Tenderer should submit GST registration certificate along with PAN card & Bank mandate while bidding / uploading tender documents.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
I / We have visited the works site and I / We am / are aware of the site conditions.
Preventive Schedule maintenance, operation, troubleshooting and up-keeping of Electrical substation at JU for a period of two years
47of2025-26~NWR
47of2025-26
Open
Works - General
24 Months
Jodhpur, Rajasthan
₹0
₹2.2 L
29 Dec 2025
5 Dec 2025
15 Dec 2025
33 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,49,87,662.48 | ||
| — | 2920.00 | — | — | ||
| Operation, up-keeping & Preventive Schedule maintenance of electrical substation 0.44/11/33 KV including maintenance of Transformer, LT/HT over-head line, trouble shooting, operation of LT/HT panel, VCB, cleaning of substation area and DG operation for a period of two years.(4 Substation x 730 days=2920) 1 job=per substation per day | — | — | — | 1,05,12,000 | |
| — | 240.00 | — | — | ||
| Maintenance and upkeep of Feeder Pillar Box as per Specification | — | — | — | 4,32,960 | |
| — | 244.00 | — | — | ||
| Maintenance & upkeep of LT MDB's as per Specification | — | — | — | 2,20,088 | |
| — | 204.00 | — | — | ||
| Maintenance & upkeep of LT Junction Boxes, precooling box and battery charging points as per Specification | — | — | — | 1,65,607.2 | |
| — | 132.00 | — | — | ||
| Maintenance & upkeep of LT panel as per Specification | — | — | — | 4,76,256 | |
| — | 26.00 | — | — | ||
| Supply, fixing and commissioning HT 11 KV XLPE heat shrinkable HT Cable end box indoor type Suitable for Cable Size 70/95 sq.mm.as per specification. | — | — | — | 2,37,067.22 | |
| — | 26.00 | — | — | ||
| Supply, fixing and commissioning HT 11 KV XLPE heat shrinkable HT Cable end box outdoor type Suitable for Cable Size 70/95 sq.mm.as per specification. | — | — | — | 3,41,804.06 | |
| — | 20.00 | — | — | ||
| Supply, fixing and commissioning HT 11 KV XLPE heat shrinkable HT Cable end box indoor type Suitable for Cable Size 185 sq.mm.as per specification. | — | — | — | 90,967.8 | |
| — | 20.00 | — | — | ||
| Supply, fixing and commissioning HT 11 KV XLPE heat shrinkable HT Cable end box outdoor type Suitable for Cable Size 185 sq.mm.as per specification. | — | — | — | 1,72,124.4 | |
| — | 100.00 | — | — | ||
| Supply, fixing and commissioning of LT Heat shrinkable Straight through Joint size (35 sq mm to 185 sq mm) as per specification. | — | — | — | 2,28,299 | |
| — | 20.00 | — | — | ||
| Supply, fixing and commissioning of Straight through cable joint kit suitable for 11KV, "E", 3 core 185 Sqmm XLPE Cable as per specification. | — | — | — | 2,67,773.8 | |
| — | 250.00 | — | — | ||
| Supply of material with excavation & commission of Foundation(C.C. Platform) for pole, panel etc. | — | — | — | 6,36,640 | |
| — | 100.00 | — | — | ||
| Supply and fixing of cover / plate of hot dip galvanized pole (5/7 mtr.) as per specification. | — | — | — | 52,429 | |
| — | 12.00 | — | — | ||
| Replacement of GO/DO Switch on existing H-pole. | — | — | — | 1,14,635.4 | |
| — | 10.00 | — | — | ||
| Replacement of Lightening arrestor. | — | — | — | 39,010.6 | |
| — | 1.00 | — | — | ||
| For any items/spares/consumable required for repair, replacement and up-keeping of sub-station, panels, Junction Box etc. If Any part/device/equipment found defective during preventive maintenance/breakdown then it is to replaced/repaired as per the specification and requirement. These items/spares/consumable apart from schedule maintenance if required will be provided by the contractor and will be paid under consumable spare for which the contractor has to submit bill of items including GST @ 18%. If any major repair job is required that also to be done using this NS with the approval of Railway and as per specification. | — | — | — | 10,00,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .