| 1 | Accepted-Technical B 13 109 NIMTALA BUS STAND P O P S KALYANI NADIA PIN 741235 | KALYANI | NADIA | WEST BENGAL | 741235 | Accepted-Technical Documents are in order |
| 2 | Accepted-Technical | Accepted-Technical Documents are in order |
| 3 | Accepted-Technical | Accepted-Technical Documents are in order |
| 4 | Rejected-Technical MATHURAPUR SONARPUR KOLKATA 700150 | KOLKATA | 24 PARAGANAS SOUTH | WEST BENGAL | 700150 | Rejected-Technical OEM authorization documents not submitted |
Tender Value
Refer Docs
EMD Value
₹94,700
Closing Date
25 Feb 2026, 4:00 pmClosed
SENIOR SUPERINTENDING ENGINEER, SEC,PWD
OFFICE OF THE SENIOR SUPERINTENDING ENGINEER, SOUTHERN ELECTRICAL CIRCLE, PWD 2ND FLOOR, MECHANICAL COMPLEX, BAGUIATI, KOLKATA 700 059
Revamping of existing Illumination system of Matla Bridge with approach road at Canning, south 24 Pgs.
2026_WBPWD_998937_1
WBPWD/SESEC/eNIT-09/25-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
90 days
Matla Bridge, canning
Please refer Tender documents.
4 documents required · 4 mandatory
₹94,700
OFFICE OF THE SENIOR SUPERINTENDING ENGINEER,SEC
11 Mar 2026
3 Feb 2026
27 Feb 2026
3 Feb 2026
25 Feb 2026
11 Feb 2026
9 Feb 2026
Feeder Pillar Box : Design, Manufacture, testing, supply and commissioning of Double door outdoor type Distribution Feeder Pillar box (H x W x B) (1000mmx860 mm x 600mm approx ) conforming to Indian Standard IS : 5039- 1969 with latest amendments,suitable for use on 3 phase 4 wire, 400/440 Volts 50 Cycles A.C. Supply and shall be suitable to be fabricated as per design & drawing to be approved by EIC. The Enclosure shall provide Degree of protection IP -66 respective Indian standard (IS). [Manufacturer/Fabricator having Test Certificates from CPRI] The body will be fabricated with 3mm thick MS plate, MS angle ( 40X40X5) & MS Flat ( 50X6 ). The top of the box will be fitted with a sloping canopy made out of 5 mm thick sheet steel. It will have double hinged door at the front and back with suitable locking arrangement (Godrej Type ) and provision for manual locking arrangement also.
Provision for Fixing WBSEDCL Meter : i) Hylam/Bakelite Sheet; size: 600mm x 600mm x 12mm (H x W x Thickness) ---- 1set. ii) 415v; 63A porcelain Kit Kat Fuse unit --- 3nos. iii) 415V; 63A nuutral link --- 1 no. inter connection should be done by suitable Cu wire (mini. size 4 core, 16 sq. mm.).
Incomer : i) 415V, 63A, FP MCCB of Breaking capacity 25kA/35kA with adjustable thermal and fixed magnetic setting (Make – L&T / Havels / SIEMENS / ABB) -- 01 No. ii) Bus-Bar : Cu 4 bars 415V, 63A. iii) LED indicator Lamp (R/Y/B) - 03 nos. iv) Danger Board
Interconnection :- All interconnection between incoming main to Busbar are to be made with suitable size flexible pvc insulated multistranded single core Cu cable and the same between busbar to each outgoing MCBs with proper socketing of the end of each wire leads.
Earthing Arrangement :- A separate continuous aluminum earth busbar of appropriate size is to be painted at the inside bottom of the panel and run across the full load of the Feeder Pillar Box. All electrical equipment are to be properly earthed with suitable size G.I. strip.
The complete Feeder Pillar Box is to be spray painted after required surface treatment by 7 tanks process / sand blasting with 2 coat of red oxide primer & 2 coat of finished paint over dried or powder coating.
Installation :- The complete feeder pillar box board is to be installed on suitable brick padestal as directed by the E.I.C.
SITC STREET LIGHT
Dismentling charge of damaged 9mtr. Swan neck type MS tubular pole & installation the same after minor repair with co's own tools and tackles or replacement by new pole identical as per direction of EIC.
Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly
Providing CC (6:3:1) muffing 600x600x760 mm in size or equivalent size of cylindrical muffing above ground level around the pole base complete with 3 mm thick neatly finished cement plaster all round after dismantling the unserviceable muffing if necessary
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of 3 nos. 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint.
S&F of 240V, 18000 Lumens (minimum) LED Street Light Fittings with IP 66/ 67, IK 10 protection including 10 KV SPD with CCT 5700K & Luminious efficacy 120Lumen/Watt minimum or better, burning hour 100000 at L70850, LED Balast should with stand 415V for 8 hours. The LED luminaires and accessories shall have BEE Certification & LED should be with lens (Light efficacy will not get depriciated less than equal to 70% of the rated value over the lifetime of the Luminaries) (Make: Transrail/ Halonix/Lighting Technology)
Supplying and Drawing 1.1 kV 3 (three) core stranded 'FR' PVC insulated & sheathed 1.5 sqmm copper cable (Make - MESCAB / GEMSCAB / RPG / UNIVERSAL / FINOLEX)
SUPPLY & LAYING OF CABLES
Supply and delivery of 1.1 KV grade 4 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables of following sizes [Make : RPG / UNIVERSAL / MESCAB / GEMSCAB]
4C X 50 sq. mm
4C X 25 sq. mm
4C X 16 sq. mm
4C X 10 sq. mm
Laying of cable as below, on existing Cable Tray/ MS angle structure and binding with suitable size GI wire. Up to 50 sqmm
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core
Cutting of RCC road of size 3"x6" depth by co's own tools & tackles for cable laying and mending good the damages to original finish.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/ PVC armoured cables as below as to GS.
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. S&F solderless socket etc as per GS.
Supplying & fixing medium gauge GI Pipe (ISI-Medium) Protection with necessary fittings and jointing metarials as required.
32 mm dia
40 mm dia
S & fixing pole clamp (191mm dia) made from 40 mm x 4 mm thick MS flat to hold 2 nos. 32 mm dia. GI pipe on 9mtr pole with necy. Nut-bolts etc as per requirement. As per GS
S & Fixing MS column clam made from 50mmx50mmx5mm equal angle and 50 mm x 5 mm thick MS flat having arrangement to fix 2 nos. PVC cable on the extended part of the clamp so that the cable can not be displaced from the original positions. The clamp is to be fixed around the 10" size cubical form concrete beam with necy. nuts-botls. As per GS
Making hole of 13 mm dia on the body of the pole for passing the wires from loop box to light fittings.
EARTHING
Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level By ISI-Medium GI pipe.
Connecting the equipments body to earth busbar including S&F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint incl. arm bracket. (i) One coat of red lead/Zinc chromate priming (ii) 1st coat of synthetic enamel paint over the primer (iii) 2nd coat of synthetic enamel paint over the 1st coat
TERMS & CONDITIONS :- The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill. If any refurbished material is supplied and installed, penal action will be taken as per existing rules The defect liability period (DLP) of the aforesaid work will be for the period of Five (05) years from date of completion.
stage.html
html • 0.03 MB
technical_2446307.pdf
techsummary_2446307.pdf
cancelled_1.pdf
pdf • 0.16 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.28 MB
BOQ_2446307.xls
BOQ • 0.38 MB
2911.pdf
Tender Documents • 2.00 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .