Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹13.7 LAdmitted-Fee/PreQual/Technical/Finance | L1 | Admitted-Fee/PreQual/Technical/Finance | ||
| 2 | L2₹14.0 L+₹26,599.83 (1.94%)Admitted-Fee/PreQual/Technical/Finance | L2 | Admitted-Fee/PreQual/Technical/Finance | ||
| 3 | L3₹14.8 L+₹1.1 L (8.22%)Admitted-Fee/PreQual/Technical/Finance | L3 | Admitted-Fee/PreQual/Technical/Finance | ||
| 4 | L4₹16.2 L+₹2.5 L (18.4%)Admitted-Fee/PreQual/Technical/Finance | L4 | Admitted-Fee/PreQual/Technical/Finance | ||
| 5 | L5₹16.4 L+₹2.7 L (19.4%)Admitted-Fee/PreQual/Technical/Finance 01 KHUMRIYAL KUPWARA KHUMRIYAL KUPWARA KUPWARA JAMMU KASHMIR 193223 | KUPWARA | JAMMU AND KASHMIR | 193223 | L5 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹19.9 L
EMD Value
₹39,701
Closing Date
13 Mar 2026, 4:00 pmClosed
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX RAJ BAGH
Construction of Divisional Office Baramulla at Deewanbagh in J.V Forest Division, Baramulla B.W.O Electric work
2026_PWDJK_305436_1
NIT No.313/2025-26 Dt/06/03/2026
Open Tender
Electrical Works
Percentage
Baramulla
Please refer Tender documents.
4 documents required · 4 mandatory
₹800
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹39,701
18 Mar 2026
7 Mar 2026
14 Mar 2026
7 Mar 2026
13 Mar 2026
7 Mar 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Wiring for Light point/Exhaust fan/Bell point with (P+N+E) 3x1.5 sq.mm FRLS-H PVC insulated Multi strand Copper conductor single core cable, (Havells/PolycabF/finolexMake) in surface/recessed Conduits laid in slabs (Including Cost of Conduit/Channel) with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified Schneider /Havells/ Legrand/Anchor roma plus/ eq. Make & shall be approved before execution of work. | 161 | Point | 1,015 | ₹1,63,415 |
| 2 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required,ISO/IEC Certified of Havells/ Legrand/Panasonic/Anchor/Schneider/ eq. Make & shall be approved before execution of work. | 19 | No. | 369 | ₹7,011 |
| 3 | Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Polycab/ Eq. Make to be approved by EIC) (Including Cost of Conduit/Channel) | 615 | Meter | 334 | ₹2,05,410 |
| 4 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified Havells/Legrand/ Panasonic/Anchor roma plus/Schneider / Eq. Make to be approved by EIC & shall be approved before execution of work. | 41 | No. | 586 | ₹24,026 |
| 5 | Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells/Polycab/Anchor / Eq. Make to be approved by EIC) (Including Cost of Conduit/Channel) | 570 | Meter | 275 | ₹1,56,750 |
| 6 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified Havells/Legrand/ Panasonic/Anchor roma plus/Schneider / Eq. Make to be approved by EIC & shall be approved before execution of work. | 38 | No. | 680 | ₹25,840 |
| 7 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required of Havells/Legrand/ Panasonic/Anchor/Schneider / Eq. Make to be approved by EIC | 20 | No. | 18 | ₹360 |
| 8 | Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Havells/Polycab/ / Eq. Make to be approved by EIC) & shall be approved before execution of work (Including Cost of Conduit/Channel) | - | - | - | - |
| 9 | 2x10 sq.mm+ 1x10 sq.mm (P+N+E) for Power point Sub main in One run from Main Panel to Distribution Boards. | 120 | Meter | 570 | ₹68,400 |
| 10 | 2x6 sq.mm+ 1x6 sq.mm (P+N+E) for Lighting Sub main in One run from Main Panel to Distribution Boards. | 120 | Meter | 439 | ₹52,680 |
stage.html
html • 0.02 MB
finance_992265.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.08 MB
BOQ_992265.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .