Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.0 CrAccepted-AOC | ₹5.0 Cr | 1 | Accepted-AOC L1 |
| 2 | 2₹5.1 Cr+₹6.6 L (1.32%)Rejected-AOC | ₹5.1 Cr+₹6.6 L (1.32%) | 2 | Rejected-AOC L2 |
| 3 | Rejected-Technical 825 GANDHI CHOWK RANIKHET 263645 DISTRICT ALMORA | RANIKHET | ALMORA | UTTARAKHAND | 263645 | - | - | Rejected-Technical Technically not qualified |
| 4 | Rejected-Technical 01 CHERSOO NH44 PULWAMA PULWAMA JAMMU KASHMIR 192123 | PULWAMA | JAMMU AND KASHMIR | 192123 | - | - | Rejected-Technical Technically not qualified |
Tender Value
₹5.1 Cr
EMD Value
₹12.8 L
Closing Date
24 Oct 2016, 4:00 pmClosed
Executive Engineer, Project Distribution Division,
Office of the Executive Engineer, Project Distribution Division, Dakpathar
Renovation and modernization of 33/11 kV substation and DPH Khodri under Project Distribution Division, Dakpathar
2016_UJVN_6181_1
01/EE/PDD/2016-17
Open Tender
Electrical Works
Item Rate
365 days
Dakpathar
Please refer Tender documents.
2 documents required · 2 mandatory
₹22,700
DGM HGC UJVNL Dakpathar
₹12.8 L
27 Sept 2023
3 Oct 2016
27 Oct 2016
3 Oct 2016
24 Oct 2016
10 Oct 2016
Amount
11KV POWER DISTRIBUTION SYSTEM: Design, manufacturing , factory testing of panels, transportation to site, supply, erection , testing and commissioning at site as per the specifications :- Outgoing Panel 1 1250Amps 11KV Indoor type panels Feeder designation : A01, A02, A03, A04, A11, A12, A13, A14.
Incomer 1 250Amps 11KV Indoor type panels Feeder designation : A05, A06, A09, A10
Bus Coupler Panel: 1250Amps 11KV Indoor type panels Panel designation: A07
Bus Riser Panel: 1250Amps 11KV Indoor type panels Panel designation: A08
Unplugging the 11KV cables from existing panels , Dismantling of existing 11KV train of panels and shifting to store.
33KV POWER DISTRIBUTION SYSTEM: Design, manufacturing , factory testing of panels, transportation to site, supply, erection , testing and commissioning at site as per the specifications : Outgoing Panel 1 1250Amps 33KV Indoor type panels with transformer protection Feeder designation :
Incomer 1 1250Amps 33KV Indoor type panels Feeder designation :
Bus Coupler Panel: 1250Amps 33KV Indoor type panels
Bus Riser Panel: 1250Amps 33KV Indoor type panels
SHORT TIME BUS FAULT CURRENT MEASUREMENT: Design, supply and installation of type tested 11 KV Bus fault current measurement system suitable for 60kA for 1 second and real time recording system as per the specifications.
HT CABLES : Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, XLPE Insulated, Insulation Screening with extruded Semi Conducting Compound in combination with Copper Tape (0.2kA for 1 sec/Core), cores laid up, innersheath of PVC tape, galvanised flat steel strip armoured and overall PVC Sheathed Cable conforming to IS 7098 / (PART-II) 1985 with latest amendments. Supply and commissioning of 33KV (E) HT XLPE Cable 240 Sq mm.
Supply and commissioning of 11KV (E) HT XLPE Cable 300 Sq MM
Supply and commissioning of 11KV (E) HT XLPE Cable 120 Sq MM
HT CABLE TERMINATIONS: Supply and commissioning 33KV Cable end termination 240 Sq. MM Out Door Type
Supply and commissioning of 33KV Cable end termination 240 Sq. MM IN Door Type
Supply and commissioning of 11KV Cable end termination 300 Sq. MM Out Door Type.
Supply and commissioning of 11KV Cable end termination 300 Sq. MM IN Door Type.
Supply and commissioning of 11KV Cable end termination 120 Sq. MM Out Door Type
Supply and commissioning of 11KV Cable end termination 120 Sq. MM IN Door Type
Supply and commissioning of Hardware Material (nut bolt, MS Channel , Chequred plate)
Supply of PPE Equipment (Electrical Gloves, Shock Treatment Chart, Fire Cylinder , Rubber Mat.)
EARTHING AND TERMINATION:- Supply and laying earthing GI Strips from panels to the earth pit
Supply and installation of GI Plate 600x600x6mm GI Earth plate
Supply, Installation, Testing and Commissioning of 6 cylinders, inline, 4 stroke cycle, Water cooled developing 1500 RPM under NTP conditions of BS:5514. The engine shall be provided with electrical starting arrangement and shall give the electrical output of 400KW/ 500KVA at 0.8 power factor, 415 Volts at the alternator terminal both mounted and aligned on a common M S base frame complete.
DISMANTLING AND RENOVATION WORKS: Dismantling of Old DG Sets
Shifting of Old DG
Dismantling of Floor of DG Hall 25X40 Meter
Dismantling of DG foundation
Dismantling of 33KV BUS
Dismantling of 11KV Old Cable
Re Making of DG Hall Floor with Kota Stone
Making of Cable Trench 1500X1500MM
Making of Cable Trench 1000X1000MM
Making RCC foundation for 500KW DG sets
Supply Erection & commissioning of 25V DC Battery Bank 200Ah with Charger and DCDB
M/S SALES AND SERVICE CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .