Loading…
Loading…
Tender Value
₹44.2 L
EMD Value
₹45,000
Closing Date
10 Sept 2026, 4:00 pm6d left
EXECUTIVE ENGINEER, AHMEDABD ELECTRICAL DN NO 1
Replacing Existing old by Providing Energy saving luminaires, BLDC Fan ,pressure pumps, at Various Building under Juridiction of J.C.Electrical Sub Dn Ahmedabad ( for The Purpose of Energy Saving in Government Building )
336483
12/01 of 2026/2027
Open
Electrical
Works
Ahmedabad
7 documents required · 7 mandatory
₹1,500
EXECUIVE ENGINEER, AHMEDABD ELECTRICAL DN NO 1,AHMEDABAD
₹45,000
19 Aug 2026
19 Aug 2026
19 Aug 2026
10 Sept 2026
19 Aug 2026
Work Name - Replacing Existing old by Providing Energy saving
luminaires, BLDC Fan ,pressure pumps, at Various Building under
Juridiction of J.C.Electrical Sub Dn Ahmedabad ( for The Purpose of Energy
Saving in Government Building )
Sr. No. Item Qty. Unit Amount Place
o o NIL NIL NIL NIL NIL
Contractor's signature Deputy Executive Engineer
J.C Electrical Sub-Division
R&B Deptt., Ahmedabad.
Executive Engineer
Ahmedabad Electrical Division-1
R&B Deptt., Ahmedabad.
Work Name - Replacing Existing old by Providing Energy saving luminaires, BLDC Fan ,pressure pumps, at Various Building under
Juridiction of J.C.Electrical Sub Dn Ahmedabad ( for The Purpose of Energy Saving in Government Building )
Item Rate in Rate in
Qty. Unit Item Description Per Amount
No. Figure Words
Providing and erecting Mains with 1.1 kV grade FRLS PVC insulated
ISI marked stranded Copper conductor wire in following type of pipe Rupees
to be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm Seventy
copper conductor FRLS PVC insulated stranded wire of green colour Eight And
1 510 Mtr 78.78 Mtr
for earth continuity of following size (A) With medium class Rigid Paise
PVC pipe and accessories (a) 2 wire 1.5 sq. mm Seventy
Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm
(Green) both are of .ISI marked 1.1 kV Grade FRLS PVC insulated
multi strand copper wires up to 10 mtr length, in below type of pipe
erected with 6A Modular type switch and hum free EME step type Rupees
electronic fan regulator mounted and accessories with earth Seven
continuity of following type erected on PVC / Metallic/Wooden box, Hundred
2 56 Pt single mounting base frame covered with textured/metallic/white 765.58 Sixty Five Pt
front plate modules erected on / in wall / ceiling as per pipe erected. And Paise
with necessary ceiling rose / H.D.Connector as directed.(a) with Fifty Eight
medium class Rigid PVC pipe and accessories erected flushed on Only
wall/ceiling complete Cat. III
Replacing Existing old & U/S By Supplying and erecting Flexible PVC Rupees
insulated multi strand multi core 1.1 kV grade ISI marked copper Fifty Eight
3 75 Mtr wires of following size to be erected as directed.(e) 1.50 Sq.mm 3 58.58 And Paise Mtr
core round PVC sheathed Fifty Eight
Energy Saving Estimate 2 /
Item Rate in Rate in
Qty. Unit Item Description Per Amount
No. Figure Words
Replacing Existing old & U/S By Supplying & erecting approved
make SMC press moulded composite FRP. loop-in, loop-out approx. Rupees
2mm thick box complete with Bakelite connector strip Four
5way(3P+N+E),DIN rail for mounting mob & hinged doors as per Hundred
4 39 Nos requirement having locking arrangements with mounting clamp 476.72 Seventy Six Ea
with nuts, bolts & washers suitable for erection on pole with cable And Paise
clamps& earth bolt of following size of box.(C)150mm x 125mm x Seventy
100mm [deep] Two Only
Replacing Existing old & U/S By Supplying and erecting B class
galvanised iron pipe 32 mm outside dia 45 cm long duly welded on Rupees
20 cm x 20 cm x 3 mm thick M.S. base plate, erected on wall or corner Three
for mounting street light luminaire with necessary hardware Hundred
5 3 Nos 343.4 Ea
materials duly painted. Forty Three
Replacing Existing old & U/S Supplying & erecting approved make
Digital time switch having lithium cell 6 years operative and operate Rupees
battery backup 1 channel day clock with 14 memory programme, Three
suitable to operate on 240V + 5%, 16A with, floating contacts Thousand
Minimum switching setup time 1 minimum & LCD display. Also One
6 6 Nos comprised permanent ON/OFF switching. Programming switches & 3168.37 Hundred Ea
housed in fire proof thermoplastic enclosure & transparent cover Sixty Eight
erected as required with necessary connection erected as directed. And Paise
(old-5 , New-1) Thirty
Energy Saving Estimate 3 /
Item Rate in Rate in
Qty. Unit Item Description Per Amount
No. Figure Words
Replacing Existing old & U/S Supplying & erecting power contactor
,AC3 duty for time switch complete erected as per direction Cat III
(C) 4 pole 440V 16 Amp. (old-5 , New-1)
7 6 Nos 857.49 Fifty Seven Ea
Replacing Existing old & U/S By Providing and erecting FRLS-XLPE
(IS:7098)(I)-88 ISI armoured cable multistrand / Solid Aluminium
conductor for 1.1 kV. to be laid on wall with necessary clamps or in
8 180 Mtr existing trench / pipe of following size of cables(A) 4 core 4 Sq. mm 140.39 Mtr
(old-165 Mtr , New-15 Mtr )
Providing & laying approved make Double walled corrugated pipes Rupees
(DWC) of polyethylene(conforming to IS 14930 II )with necessary Sixty Two
9 160 Mtr connecting accessories of same material at required depth in 62.62 And Paise Mtr
existing trench for laying of cable. below ground / road surface for Sixty Two
enclosing cable (A)50 mm outer dia Only
Making trench in soft soil of suitable width of 90 cm deep for laying Fifty Five
10 120 Mtr cable or locating the fault all over the run and back filling the same 55.55 And Paise Mtr
and making the surface as normal ground. Fifty Five
Energy Saving Estimate 4 /
Item Rate in Rate in
Qty. Unit Item Description Per Amount
No. Figure Words
Making trench in Hard Murrum / Tar Road of suitable width of 90 cm Seventy
or required depth for laying any size of cable or locating the fault all Four And
11 40 Mtr 74.74 Mtr
over the run and back filling the same and making the surface as Paise
normal ground. Seventy
12 40 Mtr (B) If additional machinery like hammer driller or JCB use [Add] 357.54 Fifty Seven Mtr
Replacing Existing old & U/S By Supply, Installation, Testing and
Commissioning of suitable sweep, BEE 5 Star rated, Ceiling fan with
Brush Less Direct Current (BLDC) permanent ferrite magnet Motor,
class of insulation: B, Rust free 3 nos.Aluminium blades, 2 nos.
canopies, shackle kit with earthing provision, copper winding, Rupees
Power factor not < 0.9, Service Value (CMM/W) minimum 6.85, Air Two
delivery minimum 215 CMM, 350 RPM,230v (tolerance as per IS : Thousand
374-2019), THD < 10%, compitible with electronic regulator unit for Six
13 706 Nos Speed Control and all remaining accessories including safety pin, nut 2629.03 Hundred Ea
bolts, washers, temperature rise = 75 °C (Max.), suitable for 140 to Twenty
285 Voltage and rectifier circuit with surge, over current and Nine And
overload protection , 50 Hz, Single phase AC Supply, earthing etc. Paise Three
Complete as required.[ Make shall be approved by Engineer in Only
Charge] (A) 1200 mm Sweep (48")
(old-650, New-56)
Energy Saving Estimate 5 /
Item Rate in Rate in
Qty. Unit Item Description Per Amount
No. Figure Words
Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S.
Pipe down rod erected duly painted for fan complete with proper Rupees One
insulation without leakage and earthing. Hundred
14 158 Mtr (old-133 Mtr, New-25 Mtr ) 108.07 Eight And Ea
Providing Fan clamp of 30 x 5 mm flat of required length & 10 mm M.S. Rupees
Bolt & Nuts erected with necessary hook of 10 mm M.S. Round Bar. Ninety
Replacing Existing old & U/S By providing and erecting Miniature Rupees
circuit breaker single pole 0.5A to 2A system and having breaking Two
capacity 10 KA to be erected in existing box. confirming to IS Hundred
8828/1996 with ISI Mark Cat.III Ninety
Energy Saving Estimate 6 /
Item Rate in Rate in
Qty. Unit Item Description Per Amount
No. Figure Words
Replace old & U/S LED indoor fittings with LEDs of wattage 0.2 Watt to
Watt assembled on single MCPCB , with housing used as a heat sink shall
be made of thick sheet Steel conforming to IS: 513/CRCA/ aluminium die
cast powder coated and high U.V. & corrosion resistance with diffuser
with company mark/name LED batten with Microwave motion technology
in which occupancy within 5m radius & 120° angle to the sensor, the Rupees Six
luminaire works at 100% of defined output specification and if no
occupancy detected within specified range, the luminaire stays at
17 259 Nos 666.6 Sixty Six Ea
occupancy mode for the first 180 to 300 seconds and then luminaire will
be turn OFF and providing an energy-efficient solution which has And Paise
specifications: 160V to 270V, Power Factor >/= 0.90, THD </=15%, CCT Sixty Only
3000 to 6500 K, CRI >/=80, Luminaire efficacy> 130 lumens/watt , and
Average life L70B50: 50000 hours (A) Tube Light with integral driver (iv)
20 Watts, Surge - 4KV,IP-20, conventional 1150 to 1200mm. (old
Convectional Tube-52 Nos+Old LED Tube-207 Nos )
Replacing old & U/S by Supplying and erecting 15 Watt LED Dimmable
Sensor cum Driver indoor Downlight fittings as per feature(1) with LEDs
of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing
used as a heat sink shall be made of thick sheet Steel conforming to IS:
513/CRCA/aluminium pressure die cast powder coated and high U.V. &
corrosion resistance with diffuser housed in aluminium casted body (2)
Motion based On-off-Dim operation(in built) (3)Adjustable detection area
50%/100%(4)Adjistaboe hold time 5s/1min/10min (5)Dimmimng %- Five
10%to 30% (6) Operating voltage range 198 to 264 AC (7) Power factor Hundred
more than 0.90 (8) Driver Efficiency more than 85% (9) Inbuilt surge Sixty Five
protection 4 KV (10) CCT 3000k to 6500k (11) Fixture efficacy more than And Paise
100 Lm/w (12) Sensor detection area 6 meter dia. (13) Square/ CFircular Fifty Only
shaped Surface/Recessed Mount Downlight with provision for spring
loaded mounting clips complete. Ip20 (14) with LM79 & LM80 Certificates
fitting requaired
(old-682 LED Downlight)+(old LED Tubelight-1061)
Energy Saving Estimate 7 /
Item Rate in Rate in
Qty. Unit Item Description Per Amount
No. Figure Words
Replacing old & U/S Dimmable LED street light / Flood light
fittings with High power White LEDs wattage of 1 Watt and above
assembled on single MCPCB, efficiency more than 100 lm/w and
corrosion free High pressure die cast aluminum housing with smooth
finish powder coated and heat sink extruded aluminium with
diffuser and Polycarbonate optics/ lenses, with
Polycarbonate/toughened glass with company mark/name
engraved or embossed, 160 to 270 V,Power Factor more than 0.95,
THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45,
Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.(
fittings required LM-79 & LM-80 certificates) Programable Motion
19 Sensor with 3 years warrantyagaist manufacturing defect :-High
Frequency DC Dimmable type sensor, having Adjustable Hold time
1Min to 20 Mins, Adjustable detection area 100% to 40%, Stand by
period 0 Sec to Infinity, Orientation Lighting 10% to 50%, Max
Mounting Height up to 15 meter and Detaction area 14-meter.Agency
has to provide a programing device to the Engineer incharge against
the total supply quantity.(A) Street Light (IP-65), Surge protection -
6KV integral and ,Light must have to sustain upto 440VAC line
supply with over-voltage protection. (old convectional fitting -7 Nos
LED Street light 120 Nos )
Energy Saving Estimate 8 /
Item Rate in Rate in
Qty. Unit Item Description Per Amount
No. Figure Words
19 Nos (A) 30Watt Dimmable LED street light Fitting 2988.59 Hundred Ea
108 Nos (B) 45Watt Dimmable LED street light Fitting 3766.29 Hundred Ea
Energy Saving Estimate 9 /
Item Rate in Rate in
Qty. Unit Item Description Per Amount
No. Figure Words
Replace old & U/S conventional motor pump by Supplying and erecting
Fully Automatic hydro pneumatic booster system with cast iron housing
Enclosure class IP44 minimum , with built in PTO motor protection and
stainless steel impeller pump, pump model Wilo WMP 3Helix V 1008 PC-
SV or GRUNDFOS Hydro multi B 3*CR 10-8 A-A-A-E-HQQE or equivalent Rupees
two pump working and one standby for support with following Seven
specifications: i) Motor data:- Power 3kw/4 HP,3 Phase motor standard Lakh(s)
IEC, motor efficiency class IE3, IP55, Insulation class F ii) Flow rate -10
CMH at 65 mtr head iii) Pump data:-stainless steel body& Impeller,Stages
& Impellers 8,Verticle Pump orientation & Maximum working pressure -16
20 1 Nos bar or 16 kg iv) GI inlet and outlet header size 50/100 mm with
717539.35 Five Ea
NRV,,Pressure switch ,pressure transmission, pressure gauge,footvalve & Hundred
other required accessories with necessary Plumbing work of suction and Thirty Nine
delivery pipe which includes all required size of pipes, Joints valves, And Paise
Bypass valve, labor all accessories required for installation of pressure Thirty Five
pump ( Foundation work and base stand cost included) along with Panel Only
HMI PLC with one VFD, Power and control contactors with necessary
Power and control switchgears, wires and cables. Control panel should be
made from Wilo, Grundfos or authorized service distributor only.
Contractor Signature
DEPUTY EXECUTIVE ENGINEER EXECUTIVE ENGINEER
J.C.ELE.SUB.DN AHMEDABAD ELECTRICAL DIVISION-1
R & B AHMEDABAD GANDHINAGAR
Energy Saving Estimate 10 /
Work Name -Replacing Existing old by Providing Energy saving luminaires, BLDC Fan ,pressure pumps, at Various
Building under Juridiction of J.C.Electrical Sub Dn Ahmedabad ( for The Purpose of Energy Saving in Government
Sr.No. Quantity Item Per Amount
1 52 Nos Cost of Old & U/S Convectional Tubelight fitting 14.60 Ea
2 1009 Nos Cost of old & U/S LED Tubelight Fitting 34.40 Ea
3 682 Nos Cost of old & U/S LED Down Light 38.90 Ea
4 7 Nos Cost of old & U/S 2*14 W T-5 Street Light 31.56 Ea
5 165 Mtr Cost of old & U/S 4*4 Sq.mm Alu Cable 8.54 Mtr
5 75 Mtr Cost of old & U/S 1.5 Sq.mm round copper Cable 13.42 Mtr
6 31 Nos Cost of old & U/S SP MCB 5.40 Ea
7 120 Nos Cost of old & U/S LED Street Light 270.60 Ea
8 5 Nos Cost of old & U/S Street Light Timer 154.70 Ea
Sr.No. Quantity Item Per Amount
9 39 Nos Cost of old & U/S pole Box 150 * 150 mm 21.45 Ea
10 3 Nos Cost of old & U/S Wall Bracket 14.85 Ea
11 650 Nos Cost of old & U/S Ceiling Fan 153.00 Ea
12 133 Mtr Cost of Old & U/S Down road 4.70 Mtr
Dy.Ex.Eng Ex.Eng
J.C.Ele.Sub Dn Ahmedabad Electrical Dn.1
R & B Ahmedabad
R & B Ahmedabad
Name of Work : Replacing Existing old by Providing Energy saving luminaires, BLDC Fan ,pressure
pumps, at Various Building under Juridiction of J.C.Electrical Sub Dn Ahmedabad ( for The Purpose of
Energy Saving in Government Building )
I / We am / are wiling to carry out the work at ____________ % Below / Above
___________(should be written in Figures and Words) the tendered amount
mentioned above,Amount of my / our tender work out as under
Put Tender Rs.- 4417815.17 Put Tender Rs.-
Less for Dismental Material Rs._____________ Less for Dismental Material Rs._____________
(A) I / We hereby declare that / We have visited the site and fully requisite my self / our selves with the local situation
regarding materials, labour and other factors pertaining to work before submitting tender.
(B) I / We hereby declare that I / We have carefully studied the condition of contract,Detailed specification and other tender
document of the work and agree to execute the same accordingly.
[1] The Rates are inclusive all taxes(Except GST),transport charges,octroi duty and storages up to date.
[2] The materials covered for wiring should be got approved from Dy.Executive Engineer in charge of the work.
[3] The materials and work shall have to be used and carried out as specification in technical naote.
[4] All works shall be carried out as per public works Department hand book and other specification of the Division of as
[5] Rate are inclusive of 1% labour cess in tender amount so 1% of total amount of bill will be deducted from the bill.
[5] Rate are inclusive of 1% labour cess in tender amount so 1% of total amount of bill will be deducted from the bill.
[6] The Agency will have to submit certificate on latter pad that Cable used in the work has been used from ISI certified cable
drum as per Note of S.E. (Elect) R.&.B. Department,Gandhinagar's No.4241,Date:-23/09/2008.
[7] Dismenatal value will not be quoted below the estimate rate.
FOR TESTING OF MATERIAL:-
[1] Material is to be used in work should be got approved by in charge E.E.
Sample of material to be used in the work is required to be tested at L.D.Engineering College of from the approved
Government Research Institute,which is must sample required to be submit as per requirement of L.D.Engineering College
or the approved Government Research Institute.In case of cable and wire 3 meters of sample and and for fluerescent fitting
5 Nos of ballast with 2 nos fluroscent lamp.may be required for testing no payment will be made on account of sample
material consideration while quoting the tender,Actual paid by agency for testing of material will be paid by the
department.Agency is requested to contact L.D.Engineering College or from the approved Government Research Institute to
understand their requirement for testing of material.
Contracor's Signature. Deputy Executive Engineer Executive Engineer
J.C Electrical Sub Division Ahmedabad Electrical Division-1
R.&.B.Department,Ahmedabad. R.&.B.Department,Ahmedabad.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Notice no.12.pdf
GR AND GST LTR.pdf
PQ CRITERIA.pdf
SBD Document.pdf
SCHEDULE A B C AND DM.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].