Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.2 LAccepted-AOC H NO 8 9 29 ASOKE NAGAR OLD GAJUWAKA VIZAG 530028 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530028 | L1 | Accepted-AOC Lowest Bid Accepted | |
| 2 | L2₹51.6 L+₹3.4 L (7.00%)Rejected-Finance | L2 | Rejected-Finance Not Being Lowest Bidder | |
| 3 | L3₹71.0 L+₹22.7 L (47.2%)Rejected-Finance | L3 | Rejected-Finance Not Being Lowest Bidder | |
| 4 | L4₹75.1 L+₹26.8 L (55.7%)Rejected-Finance | L4 | Rejected-Finance Not Being Lowest Bidder | |
| 5 | L5₹75.3 L+₹27.0 L (56.1%)Rejected-Finance DOOR NO 50 13 27 14 FLAT NO 14 PADMAJA APARTMENTS SEETHAMMAPETA VISAKHAPATNAM 530016 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530016 | L5 | Rejected-Finance Not Being Lowest Bidder |
Tender Value
₹75 L
EMD Value
₹1.4 L
Closing Date
8 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri VK Tiwari, IDSE, Commander Works Engineer
Commander Works Engineers, Station Road, Visakhapatnam - 530 004
External Periodical Services to Multi Storey Buildings including Non-Structural Repairs, Repairs to Vertical Stacks, Removal of Vegetation at NORA, Visakhapatnam
2021_MES_475854_1
82187 /E8
Open Tender
Civil Works
Item Rate
180 days
Visakhapatnam
Class C Category a i
8 documents required · 8 mandatory
₹1,000
Garrison Engineer Naval Base
₹1.4 L
Yes
15 Dec 2021
4 Oct 2021
15 Nov 2021
4 Oct 2021
8 Nov 2021
25 Oct 2021
4 Oct 2021 - 11 Oct 2021
60 days
Amount
M & L for One coat of white wash on old decorated surfaces of walls, pillasters, cornices, etc., including necessary preparation of surfaces by brooming down or steel wire brushing complete all as specified and as directed.
M & L for One coat of white wash on old decorated ceilings, soffits, etc. including necessary preparation of surfaces by brooming down or steel wire brushing complete all as specified and as directed.
M & L for One coat of Acrylic Washable Distemper on on old decorated surfaces of walls, pillasters, cornices, etc., including necessary preparation of surfaces by washing, rubbing down and stopping complete all as specified and as directed.
M & L for One coat of Weather Proof Exterior Emulsion Paint [100% Acrylic] on Walls/ ceilings, pillasters, bands, borders, soffits of chajjas and projections including necessary preparation of surfaces by washing, rubbing down and stopping complete all as specified and as directed.
M & L for Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] over a Coat of Weather Proof Exterior Primer of same manufacturer as that of paint on newly plastered wallss/ ceiling, pillasters, bands, borders, soffits of chajjas and projections including necessary preparation of surfaces complete all as specified and as directed.
M & L for One coat of aluminium paint on old painted steel surfaces of any description not other wise described over 10 cm width or girth incuding necessary preparation of surfaces complete all as specified and directed.
Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces etc including raking out joints, hacking for key scrubbing down with water etc and removing rubbish to a distance exceeding 1.50 KM but not exceeding 5.00 KM complete all as specified and as directed.
M & L for rendering to brick / concrete surfaces, 15 mm thick in Cement Mortar 1:4, including mixing water proofing compound as per manufacturers instructions and finishing the top surface even and smooth without using extra cement complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
Supply only integral water proofing compound [ISI marked] of approved make.
M & L for rendering 5 mm thick in Cement Mortar 1:3 on fair faces of concrete surface of ceiling surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M & L for Three coats of white washing on newly plastered surfaces of walls, pillasters, cornices, etc., including necessary preparation of surfaces complete all as specified and as directed.
M & L for Three coats of white washing on newly plastered surfaces of ceilings, soffits, etc., including necessary preparation of surfaces complete all as specified and as directed.
M & L for Cutting / Chipping the spalling concrete surfaces of Slabs, Beams, Columns, Fins, Facias, Chajjas, Parapets, etc. and trimming, cleaning the surfaces of any thickness to receive Guniting / Plastering, preparing surfaces and applying a coat of Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions and providing pressure Guniting averaging 40mm thick at a pressure of not less than 6 KG / Sq.cm in Cement Mortar 1:3 mixed with and including suitable bonding agent of M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. @ 5% of weight of cement for sides and soffits of Beams, Columns, Fins, Parapets and Facias etc., finishing surface rough conforming to proper geometrics including providing double scaffolding and safety measures as required and removal of the same on completion and disposal and depositing the demolished material out of a distance exceeding 1.50 KM but not exceeding 5.00 KM complete all as specified and as directed.
M & L for Cutting / Chipping the spalling concrete surfaces of Slabs, Beams, Columns, Fins, Facias, Chajjas, Parapets, etc. and trimming, cleaning the surfaces of any thickness to receive Guniting / Plastering, preparing surfaces and applying a coat of Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions and providing pressure Guniting averaging 30mm thick at a pressure of not less than 6 KG / Sq.cm in Cement Mortar 1:3 mixed with and including suitable bonding agent of M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. @ 5% of weight of cement for sides and soffits of Beams, Columns, Fins, Parapets and Facias etc., finishing surface rough conforming to proper geometrics including providing double scaffolding and safety measures as required and removal of the same on completion and disposal and depositing the demolished material out of a distance exceeding 1.50 KM but not exceeding 5.00 KM complete all as specified and as directed.
M & L for Cutting / Chipping the spalling concrete surfaces of Slabs, Beams, Columns, Fins, Facias, Chajjas, Parapets, etc. and trimming, cleaning the surfaces of any thickness to receive Guniting / Plastering, preparing surfaces and applying a coat of Nito Bond AR of M/s. Fosroc Chemicals or equivalent approved bonding agent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. as per manufacturer's instructions and providing pressure Guniting averaging 20mm thick at a pressure of not less than 6 KG / Sq.cm in Cement Mortar 1:3 mixed with and including suitable bonding agent of M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. @ 5% of weight of cement for sides and soffits of Slabs & Chajjas etc., finishing surface rough conforming to proper geometrics including providing double scaffolding and safety measures as required and removal of the same on completion and disposal and depositing the demolished material out of a distance exceeding 1.50 KM but not exceeding 5.00 KM complete all as specified and as directed.
Demolition of Reinforced Cement Concrete [reinforcement cut as required to facilitate demolition] of any description and in any position not otherwise specifically provided for and removing rubbish to a distance exceeding 1.50 KM but not exceeding 5.00 KM complete all as specified and as directed.
Use and removal of steel formwork to chullah hoods, Chajjas, troughs and similar works including edges for fair finished surfaces of concrete complete all as specified and directed.
Use and removal of steel formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick [horizontal or sloping] for fair finished surfaces of concrete complete all as specified and directed.
Use and removal of steel formwork to sides of pillars, posts, struts, piers, columns and stanchions of any shape / cross section for fair finished surfaces of concrete complete all as specified and as directed.
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 6mm to 8mm dia, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
M & L for Welding in repairs exceeding 2.5cm but not exceeding 5cm in length and thickness of metal welded exceeding 6mm and not exceeding 9mm complete all as specified and as directed.
S & F Reinforcement using High Strength Corrosion Resistant Deformed TMT Bars of Grade Fe–500D of 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping, hooking ends and binding with annealed mild steel wire not less than 0.9mm dia or securing with clips or welded complete all as specified and as directed.
M & L for Welding in repairs exceeding 2.5cm but not exceeding 5cm in length and thickness of metal welded exceeding 9mm and not exceeding 20mm complete all as specified and as directed.
M & L for RCC M-20 Design Mix, using 20mm graded stone aggregate as in Columns, pillars, piers, posts and struts etc. complete all as specified and as directed.
M & L for RCC M-20 Design Mix, using 20mm graded stone aggregate as in Beams, Cantilevers, Bressummers, Lintels over 1.5m span etc. complete all as specified and as directed.
M & L for RCC M-20 Design Mix, using 20mm graded stone aggregate as in Chajjas and the like etc. complete all as specified and as directed.
M & L for RCC M-20 Design Mix, using 20mm graded stone aggregate as in Facias & Fins, Parapets, etc. complete all as specified and as directed.
M & L for rendering to brick / concrete surfaces, 10 mm thick in Cement Mortar 1:3, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M & L for Welded steel wire fabric of weight not exceeding 4 Kg per Sq.m fixed to steel or wooden members with suitable fixtures complete all as specified and as directed.
M & L for Non-Shrink, Cementitious Micro Concrete using Rendroc RG' manufactured by M/s. Fosroc Chemicals India [P] Ltd. or its equivalent in M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. modified with 12mm graded, clean, saturated surface dry crushed stone aggregate in the ratio as per manufacturer's instructions, laid in average thickness of 80 to 100mm in columns, beams and similar structural members including use and waste of water tight formwork to facilitate pouring of micro concrete complete all as per manufacturer's instructions including providing double scaffolding and safety measures as required and as specified. Note: Measurement shall be considered for circumference at centerline of core thickness.
Demolition of Unreinforced Cement Concrete of any description and in any position not otherwise specifically provided for and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed.
S & F in repairs 0.71 mm thick Plain Aluminium Sheet Alloy 31000 H4 in Ridges, Hips, Valley Gutter, drip and straight flashing, Cover for Crumple Joint complete all as specified and as directed.
M & L for cleaning of RCC Water Tanks of 20000 to 40000 Litres Capacity located at various places at any height by removing the inlet and outlet coupling connections, emptying all dirty / muddy water from the tanks using Diesel / Electric Driven Non-Clogging Pumps, removing the Scale / Sludge / Mud / Algae formed including other foreign materials got deposited on sides of walls and bottom of the tanks by scrapping and brushing with wire brush, cleaning with pressure pump, washing with bleaching powder slurry and allowing to dry and then washing and cleaning the tank with fresh water, applying two coats of white wash on all internal surfaces and writing the details of tanks like Date of Cleaning, Capacity of Tank and Due Date for Next Cleaning etc. on the out side of the tank with Synthetic Enamel Paint with letters of size 20 cm high, 10cm width in White colour over Black background of size 600 X 300mm including cleaning of platform, replacement of unserviceable/ defective inlet and outlet coupling and fittings etc. complete all as specified and as directed.
S & F in repairs Ball Valves, 50 mm Bore, high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe etc complete all as specified and as directed.
Taking down or up steel tubing and connections for 15 mm bore of pipe complete all as specified and as directed.
S & F CPVC Pipes 16 mm outer diameter SDR 11 & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
Taking down or up steel tubing and connections for 20 mm bore of pipe complete all as specified and as directed.
S & F CPVC Pipes 25 mm outer diameter SDR 11 & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
Taking down or up steel tubing and connections for 25 or 32 mm bore of pipe complete all as specified and as directed.
S & F CPVC Pipes 32 mm outer diameter SDR 11 & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
Taking down or up steel tubing and connections for 40 or 50 mm bore of pipe complete all as specified and as directed.
S & F CPVC Pipes 50 mm outer diameter SDR 11 & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
Taking down or up steel tubing and connections for 80 mm bore of pipe complete all as specified and as directed.
S & F CPVC Pipes 75 mm outer diameter SDR 11 & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing complete all as specified and as directed.
S & F in repairs Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 MPa, 15 mm bore with iron wheel head, screwed both ends for iron pipe, conforming to IS, ISI Marked complete all specified and as directed.
S & F in repairs Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 MPa, 25 mm bore with iron wheel head, screwed both ends for iron pipe, conforming to IS, ISI Marked complete all specified and as directed.
S & F in repairs Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 MPa, 50 mm bore with iron wheel head, screwed both ends for iron pipe, conforming to IS, ISI Marked complete all specified and as directed.
S & F in repairs Gun Metal Globe or Gate Valve of Class - I, Pressure Tested of 1.5 MPa, 75mm bore with iron wheel head, screwed both ends for iron pipe, conforming to IS, ISI Marked complete all specified and as directed.
M & L for cutting holes into or through brick walls built in cement mortar and walls of cement concrete and making good in Cement Mortar 1:3 or Cement Concrete 1:2:4, Type B-1 as required for superficial area not exceeding 150 Sq.cm complete all as specified and as directed.
M & L for cutting holes into or through brick walls built in cement mortar and walls of cement concrete and making good in Cement Mortar 1:3 or Cement Concrete 1:2:4, Type B-1 as required for superficial area exceeding 500 Sq.cm and not exceeding 0.10 Sq.m complete all as specified and as directed.
M & L for cutting holes into or through cement concrete slabs, Chajjas, etc. reinforced or otherwise for superficial area exceeding 500 Sq.cm and not exceeding 0.1 Sq.m complete all as specified and as directed.
M & L for cutting holes into or through stone walls built in cement mortar and walls of cement concrete and making good in Cement Mortar 1:3 or Cement Concrete 1:2:4, Type B-1 as required for superficial area exceeding 500 Sq.cm and not exceeding 0.10 Sq.m complete all as specified and as directed.
M & L for cutting holes into or through cement concrete slabs, Chajjas, etc. reinforced or otherwise for superficial area exceeding 250 Sq.cm and not exceeding 500 Sq.cm complete all as specified and as directed.
Taking down CI / PVC SWR pipes of any dia (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., (measured overall as fixed along the centre line over fittings and accessories) all as specified and as directed .
S & F 160mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps complete all as specified and as directed.
S & F 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S & F 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps complete all as specified and as directed.
S & F 110mm bore PVC [SWR] WC connector with lip ring including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Junction Single [Single "T"] equal or unequal with access door including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Bends of any radius with Access Door including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Vent Cowl including jointing with solvent cement complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Bends [any radius] with duck's foot or heel rest, including jointing with solvent cement complete all as specified and as directed.
S & F Cast Iron cowls of 100 mm dia complete all as specified and as directed.
S & F 110 mm bore PVC [SWR] Bends of any radius including jointing with solvent cement complete all as specified and as directed.
S & F in repairs Stack clamps made out of 50 X 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 110mm dia pipes complete all as specified and as directed.
M & L for removing Plants with roots by chipping Walls / Beams / Junctions of Vertical Stacks / Water Supply lines or at any other location as directed, applying recommended chemical to prevent growth or plants and making good the disturbed portion with Cement Mortar 1:3 or with PCC 1:2:4, Type B0 [using 12.5 mm graded aggregate] and painting the surfaces to match with existing treatment / finishes and removing debris to a distance exceeding 1.50 KM but not exceeding 5.00 KM complete all as directed.
M & L for Writing letters or figures [Block, Roman, Italic or Indian] not exceeding 30 cm high with thick paint to stand out boldly and solidly without showing signs of brush marks complete all as specified and as directed.
M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 KG of cement per Sq.m area, rendering 10mm thick in cement mortar 1:3 on concrete surfaces finished even and smooth without using extra cement including mixing of water proofing compound of approved make as per manufacturers instructions for levelling the surface smooth to receive the water proofing membrane, priming the surface with a coat of cold applied bituminous primer @ 0.50 KG per Sq.m, applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m, laying Polymeric water proofing membrane of weight not less than 3.00 Kg per Sq.m reinforced with polyester non-woven fabric of weight not less than 150 Grams per Sq.m, by torch application with side over lap of 100mm & end over lap of 150mm & tucked into the chases on vertical surfaces by thermo fusion including applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m on top for water proofing treatment complete including taking down existing Roof Treatment of any description including PCC padding of any description and removing rubbish to a distance exceeding 1.50 KM but not exeeding 5.00 KM complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
M & L for 25 mm average thick, PCC 1:2:4, Type B-0, using 10mm graded aggregate as in Padding over roof slabs etc. and finishing the top surface rough complete all as specified and as directed.
M & L for Plain / Chequered Cement Concrete Tiles of size 300 X 300 mm, 25mm thick, Hydraulically pressed as in Floors, set jointed and pointed in neat cement slurry to match including screed bed or bedding layer of mortar 20 mm thick in Cement Mortar 1:4 complete all as specified and as directed.
Note for Serial Item No. 1 to 70: The work shall be carried out up to Tenth Storey heights / 33 metre hights and the rates quoted are deemed to be including providing double scaffolding and safety measures as required and removal of the same on completion complete all as specified and as directed. Nothing shall be paid extra on this account.
ANUJ INFRA
KSN PROJECTS
PEARL CORPORATION
P SRINIVASA RAO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .