| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 CrAccepted-AOC 4TH FLOOR VOLTAS HOUSE A BLOCK DR BABASAHEB AMBEDKAR ROAD CHINCHPOKLI MUMBAI MAHARASHTRA 400033 | MUMBAI | MAHARASHTRA | 400033 | ₹2.7 Cr | L1 | Accepted-AOC The firm is L1 |
| 2 | L2₹3.5 Cr+₹79.1 L (28.8%)Rejected-Finance EP 284 H NO 18 3 SAYYED WARA FARIDABAD HARYANA 121002 | FARIDABAD | HARYANA | 121002 | ₹3.5 Cr+₹79.1 L (28.8%) | L2 | Rejected-Finance The firm is L2 |
| 3 | L3₹3.8 Cr+₹1.0 Cr (37.8%)Rejected-Finance 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | ₹3.8 Cr+₹1.0 Cr (37.8%) | L3 | Rejected-Finance The firm is L3 |
| 4 | L4₹4.1 Cr+₹1.3 Cr (49.1%)Rejected-Finance | ₹4.1 Cr+₹1.3 Cr (49.1%) | L4 | Rejected-Finance The firm is L4 |
| 5 | L5₹4.1 Cr+₹1.4 Cr (50.8%)Rejected-Finance 404 ITL TWIN TOWERS PLOT NO B 9 NETAJI SUBHASH PLACE PITAMPURA NEW DELHI | NORTH WEST | DELHI | 110034 | ₹4.1 Cr+₹1.4 Cr (50.8%) | L5 | Rejected-Finance The firm is L5 |
Tender Value
₹4.3 Cr
EMD Value
₹8.5 L
Closing Date
13 Aug 2022, 6:00 pmClosed
AGM EE
AAI Ops. Building, NSCBI Airport Kolkata
Modification of cooling arrangement and illumination inside fixed fingers of Aerobridges at NSCBI Airport, Kolkata.
2022_AAI_120390_1
AAI/EMD-III/Modification of Aerobridge/22-23
Open Tender
Electrical Works
Works
180 days
AAI Ops. Building, NSCBI Airport Kolkata
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,120
₹8.5 L
10 Nov 2022
19 Jul 2022
16 Aug 2022
20 Jul 2022
13 Aug 2022
20 Jul 2022
20 Jul 2022 - 26 Jul 2022
Amount
SH-I : SITC of Air Conditioning works
Supply, Installation, testing and Commissioning of four way chilled water cassette Fan Coil unit with 2 row deep chilled water cooling coil, inbuild drain pump and wireless remote control complete with all necessary valve arrangement i.e. Ball valve with strainer, Ball valve with out strainer and control valve with acuator and thermostat.
3.0 TR, 1200 CFM
Valve station consist of on-off Ball valve set with strainer and without strainer of 3/4" x 5/8” size and with 2way on-off valve of 25mm and Copper tubing of 5/8” size duly insulated fitted with necessary fittings of suitable size. VS-101 valve station can be used for 2.5 to 4ton capacity Cassette Fan coil unit.
Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building/masonary ducts (with necessary clamps, vibration isolators, bends, reducers, tees, supports, flow indicators etc fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / m3 density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class ‘O’ insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150 mm & below shall be M.S. ‘C’ class as per IS : 1239. (Thickness of the nitrile insulation shall be 32 mm).
200 mm Dia
150 mm Dia
100 mm Dia
80mm Dia
65mm Dia
40mm Dia
32mm Dia
Supply and installation of CPVC Drain Pipe with 9mm thick class O fire rated nitrile rubber insulation of following dia.
25mm Dia
40mm Dia
Supply, fixing, testing and commissioning of following valves, strainers, etc. duly insulated with same specifications as that of connected piping complete with companion flanges, nuts, bolts, gaskets, adequate support etc. as specified.
BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot water circulation as specified
Steel work in M.S. Tubular section /M.S. Square section /M.S. Plates i/c cutting to required length welding & fixing the members to RCC/Brick structure/Pre-fabricated structure with anchor fastners as per releavent drawing and direction by the Engg. -in-Charge i/c application of one coat epoxy primer on exposed surfacess.(75 micron thick) and Polyurethene Painting of 75 micron DFT
Supplying, laying,testing & commissioning of the following sizes of 1.1 KV armoured PVC insulated flexible copper conductor cables conforming to relevant latest amended Indian Standards laid over MS supports including clamping the cables to supports in an approved manner as required complete with all accessories.
3C x 2.5 sq.mm Flexible copper cable
Supply, Installation, testing , balancing and Commissioning of the following items as per approved working drawings, specifications and requirement.
G.S.S square/ rectangular factory fabricated ducting complete with gaskets, elbows, splitters, vanes, supports etc. as per drawings and as required for air distribution.
18 gauge
20 gauge
22 gauge
Supplying and fixing of following thickness closed cell Nitrile rubber (Class “O”) insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required
25 mm thickness
Dismantling of existing Cassette units inside the Aerobridges including dismantling the existing CHW and Drain pipes, Ducts, Diffusers etc. and shifting the same to AAI dismantle store/ garbage pit as required i/c dismantling all civil materials such as ACP/false ceiling etc. for carrying out the erection work as required or as per instruction of EIC. **Refixing Work with ACP sheets around AC units is considered in Item No.3 of SH-II. Note: Each Job is for One Aerobridge and Each Aerobridge has 8-10 Casette Units in the existing system.
Supply, installation, testing and commissioning following Power Plug-socket and switch along with suitable modular box ,modular base and cover plate for Chilled Water Cassette units.
Supplying, laying,testing & commissioning of the following size of cable tray conforming to relevant latest amended Indian Standards laid over MS supports including clamping the cable trays to supports in an approved manner as required complete with all accessories.
Cable tray 150mmx50mmx1.6mm
SH-II : Electrical Works
Supply, Installation, Testing & Commissioning of 21 to 25W RECESS MOUNTING DOWNLIGHTER having minimum system Lumen output of 1900 lumen or more, White powder coated, elegantly designed pressure die-cast aluminium heat sink for efficient heat dissipation & white finish polycarbonate ring for holding the diffuser, Mirror finish anodized reflector with facets for uniform light distribution, High efficiency long life SMD LED module, Powered by integral SMPS based constant current electronic driver with lower THD, Output Short Circuit Protection, Surge Voltage Protection and other safety tests as latest as IS specification & fixing suitably into false ceiling by 2 nos. of SS springs / clips including connections with 1.5 sq. mm single core FRLS PVC insulated copper flexible cable and earthing etc. complete as required.
Dismantling of 2 x 18W T5 LED 4ft long conventional FTL from the false ceiling of aero bridge at Terminal-2 and other locations as required, taking adequate safety measures including transporting and storing the dismantled fixtures at AAI store complete as required.
Providing, fabricating, fixing of 4mm thick Aluminium Composite Panel of approved make and shade comprising of both side skin of 0.50mm thick aluminium alloy sheet of grade A303 at required location on existing frames including cutting the grooves and finishing with silicon sealant all complete as where as required as per direction of engineer-in-charge.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
(a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor power cable conforming to IS 7098 (Part 1) amended upto date.
(a) 4C X 35 Sq.mm
Laying and fixing of one number PVC insulated PVC sheathed / XLPE power cable of 1.1 KV grade of following sizes on wall / surface as required.
(a) Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying and fixing of one number PVC insulated PVC sheathed / XLPE power cable of 1.1 KV grade of following sizes on cable tray as required.
(a) Upto 35 sq. mm (clamped with 1mm thick saddle)
Supplying and making indoor cable end termination with brass compression gland and aluminium lugs for following size of PVC insulated PVC sheathed/ XLPE aluminium conductor cable of 1.1 kV grade as required.
(a) 4 X 35 sq. mm (32mm)
PROFIS ENGINEERS PVT LTD
Blue Star Ltd
Intelectra Aire Projects Pvt Ltd
HV AIRCONDITIONING SYSTEMS PVT. LTD.
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .