| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Clean Agent fire extinguisher HCFC123 02 Kg. | CF-000024 | - | 12 NOS | ₹16,504 | 198,048 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.0 LQualified Make: ceasefire
Model: CF- 000024 602 DOLI CHAMBERS 06TH FLOOR BRAHMAKUMARIS MARG NEAR STRAND CINEMA COLABA MUMBAI CITY 2829 400058 INDIA | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | Make: ceasefire
Model: CF- 000024 | L1 | Qualified | |
| 2 | Disqualified Make: FIRECHEM
Model: FC-142 B 4 2ND FLOOR RAMA PALACE COMMERCIAL COMPLEX NEAR AJRONDA MODH B 4 2ND FLOOR RAMA PALACE COMMERCIAL COMPLEX NEAR AJRONDA MODH SECTOR 20 B FARIDABAD | Make: FIRECHEM
Model: FC-142 | - | Disqualified | |
| 3 | Disqualified Make: NA
Model: SFCA2 16 1ST FLOOR CHUNAWALA BUILDING NEAR AL SADIQ HOSPITAL MOHAMMAD ALI ROAD MANDVI MUMBAI MAHARASHTRA 400003 | MUMBAI | MAHARASHTRA | 400003 | Make: NA
Model: SFCA2 | - | Disqualified | |
| 4 | Disqualified Make: intime
Model: INTIME CLEAN AGENT 2 KG 00 BEHIND ISHA HOSPITA CHITRAGUPT COLONY UMARPUR HARIBANDAHANPUR JAUNPUR UTTAR PRADESH 222002 | JAUNPUR | UTTAR PRADESH | 222002 | Make: intime
Model: INTIME CLEAN AGENT 2 KG | - | Disqualified | |
| 5 | Disqualified Make: intime
Model: CA2 21 A GHANSHYAM INDL ESTATE VEERA DESAI ROAD ANDHERI MUMBAI MAHARASHTRA 400053 | MUMBAI SUBURBAN | MAHARASHTRA | 400053 | Make: intime
Model: CA2 | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
12 Jul 2018, 6:00 pmClosed
Portable Fire Extinguishers IS 15683 Portable Fire Extinguishers IS 15683 ( 12 ) Technical Specifications Specification Specification Name Values Allowed Values Generic Conformity to Standard IS:15683:2006 With Latest Amdmnt. - Type Stored Pressure Stored Pressure
Gas Cartridge Type Extinguishing Media Clean Agent Clean Agent Expellant Medium N2 Based (Stored Pressure) CO2 Cartridge Based
N2 Based (Stored Pressure)
CO2 Extinguishing Medium Constructional Foam Based Extinguishing Media NA - Powder Based Extinguishing Media NA - Clean Agents Based Extinguishing Media HCFC - Foam Based Fire Extinguisher Capacity(Ltrs) NA 2
4
6
9
NA Powder Based Fire Extinguisher Capacity (Kg) NA 1
2
NA Carbon Dioxide Based Fire Extinguisher NA 2
3
4.5
NA 1/4 Capacity (Kg) Water Based Fire Extinguisher Capacity NA 2
NA Clean Agents Fire Extinguisher Capacity (Kg) 2 2 Weight of Filled Portable Fire Extinghuisher (Kg) 3.7 Rechargebale true - Color Coding Red - Fire Extinguisher Suitable for Class -A Fire true - Fire Extinguisher Suitable for Class -B Fire true - Fire Extinguisher Suitable for Class -C Fire true - Fire Extinguisher Suitable for Class -D Fire false - Fire Extinguisher Suitable for electrical Fire true - Performance Operating Temperature (° C) -30° C to + 55° C - Test pressure/Burst Pressurire Extinguisher except CO2 for Clean agent fire extinguisher Test Pressure >=30 Bar
Burst Pressure >=55 Bar - Test pressure/Burst pressure for CO2 type Extinguisher (write NA if not applicable) NA - Discharge Range for Extinguisher (Meters) >=2 for Class-A - Effective Discharge Time for Fire Extinguisher
Min (Seconds) 10.45 Fire Rating for Class -A Fire Extinguisher NA - Fire Rating for Class -B Fire Extinguisher 8B - 2/4 Certification BIS Marking Yes - CM/L No.* with Validity Period 8886112 with validity of 31/03/2019 - Availability of Test Report from Central Govt./NABL/ILAC accredited lab to prove conformity to specification YES - Test Report No. 110124 - Test Report Date 02/03/2012 - Name of the Lab Fire Test & Research Laboratory - Address of the Lab 9th Milestone
SH-11
Sonipath-Gohana Road
Rattangarh
Sonipat-131001 - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Dhaval Dave 380007
National Institute of Design
Paldi 12 15 EMD Required No ePBG Required No
248672
GEM/2018/B/35357
GeM Contract
Portable Fire Extinguishers IS 15683
GeM Contract
15 days
Gujarat; Ahmadabad
PRODUCT
Awarded to CEASEFIRE INDUSTRIES PRIVATE LIMITED
₹2.0 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Clean Agent fire extinguisher HCFC123 02 Kg. | CF-000024 | - | 12 NOS | ₹16,504 | 198,048 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Portable Fire Extinguishers IS 15683 Portable Fire Extinguishers IS 15683 ( 12 ) Technical Specifications Specification Specification Name Values Allowed Values Generic Conformity to Standard IS:15683:2006 With Latest Amdmnt. - Type Stored Pressure Stored Pressure | - | - | - |
| Gas Cartridge Type Extinguishing Media Clean Agent Clean Agent Expellant Medium N2 Based (Stored Pressure) CO2 Cartridge Based | - | - | - |
| N2 Based (Stored Pressure) | - | - | - |
| CO2 Extinguishing Medium Constructional Foam Based Extinguishing Media NA - Powder Based Extinguishing Media NA - Clean Agents Based Extinguishing Media HCFC - Foam Based Fire Extinguisher Capacity(Ltrs) NA 2 | - | - | - |
| 4 | - | - | - |
| 6 | - | - | - |
| 9 | - | - | - |
| NA Powder Based Fire Extinguisher Capacity (Kg) NA 1 | - | - | - |
| 2 | - | - | - |
| NA Carbon Dioxide Based Fire Extinguisher NA 2 | - | - | - |
| 3 | - | - | - |
| 4.5 | - | - | - |
| NA 1/4 Capacity (Kg) Water Based Fire Extinguisher Capacity NA 2 | - | - | - |
| NA Clean Agents Fire Extinguisher Capacity (Kg) 2 2 Weight of Filled Portable Fire Extinghuisher (Kg) 3.7 Rechargebale true - Color Coding Red - Fire Extinguisher Suitable for Class -A Fire true - Fire Extinguisher Suitable for Class -B Fire true - Fire Extinguisher Suitable for Class -C Fire true - Fire Extinguisher Suitable for Class -D Fire false - Fire Extinguisher Suitable for electrical Fire true - Performance Operating Temperature (° C) -30° C to + 55° C - Test pressure/Burst Pressurire Extinguisher except CO2 for Clean agent fire extinguisher Test Pressure >=30 Bar | - | - | - |
| Burst Pressure >=55 Bar - Test pressure/Burst pressure for CO2 type Extinguisher (write NA if not applicable) NA - Discharge Range for Extinguisher (Meters) >=2 for Class-A - Effective Discharge Time for Fire Extinguisher | - | - | - |
| Min (Seconds) 10.45 Fire Rating for Class -A Fire Extinguisher NA - Fire Rating for Class -B Fire Extinguisher 8B - 2/4 Certification BIS Marking Yes - CM/L No.* with Validity Period 8886112 with validity of 31/03/2019 - Availability of Test Report from Central Govt./NABL/ILAC accredited lab to prove conformity to specification YES - Test Report No. 110124 - Test Report Date 02/03/2012 - Name of the Lab Fire Test & Research Laboratory - Address of the Lab 9th Milestone | - | - | - |
| SH-11 | - | - | - |
| Sonipath-Gohana Road | - | - | - |
| Rattangarh | - | - | - |
| Sonipat-131001 - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Dhaval Dave 380007 | - | - | - |
| National Institute of Design | - | - | - |
| Paldi 12 15 EMD Required No ePBG Required No | - | - | - |
Exempted
2 Aug 2018
25 Jun 2018
contract_GEMC-511687714980568.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_248672.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .