| Sl No | Description | Qty | Unit | M/S K S ENGG WORKS L3 | N B Engineering and Electric Works L1 | BEE AAR ENTERPRISES L2 |
|---|---|---|---|---|---|---|
| 1.00 | Providing, Fitting and Fabrication of 2 Nos. MS Pipe bends of suitable angle as per site conditions from the available 200mm dia MS pipe of 1.5m overall average length with a wider curve, providing & fitting with MS Flanges 200 mm dia of standard thickness at two ends, which are properly circumferentially welded with ISI marked M.S welding electrodes, weld should free of spurts and gaps & all the slag was removed by chipping. The job also includes complete painting by way of removing the rust/dirt from the outer surface of the pipe by sanding away with emery/sand papers/steel wire brush, cleaning and making the surface even for painting then apply one coat of primer and two coats of paint on all exposed parts. P/F of 200mm dia MS pipe 13 m approximately for 2 no. suctions lines of unit I and II, by way of preparing the ends with the flanges of appropriate size to be coupled with bends. The job also involves cutting of the MS pipes as per site requirements by gas cutter. Aligning the suction lines with tools and tackles using skilled labour. Strengthening and support of MS suction pipe by installation of hooks/ clamps on either side of the MS pipe by grouting MS angles (50x50x6 mm) after excavation of pits of size(1’x1’x1.5’) and fixing with cement concrete mixture along the length of each suction pipe at 8 spots. after curing for 5 days welding the angles and suction pipe for extra strength/support to suction pipes. M.S Flanges to have suitable drilled holes to match the joining pieces & faced for perfect fit. The job included cost of welding electrodes, Oxy-acetylene gas equipment, tools & tackles required for the job, hire and carriage charges to and fro, cost of material, Cost of use of Lathe facilities for flanges, beveling of pipes by hand grinders at site wherever required etc. & labour charges for skilled & semi-skilled labour, transportation and handling charges all to be borne by the tenderer. | 1 | 01 job | 1,09,500 ₹1,09,500 | 1,08,200 ₹1,08,200 Lowest | 1,09,100 ₹1,09,100 |
| 2.00 | Providing, Fitting and installation of 2 Nos. 250 mm dia foot valves for pumping unit no. I and II by way of welding 2 No. flanges as per foot valves sample/size to 2 No. 200 dia MS suction pipe piece (provided in item no 1) and installing both foot valves on each MS suction pipe end by p/f of appropriate no. of nuts, bolts and rubber gaskets as per size. Job further involves lowering of the foot valves along with suction piece by using chain pulley block and skilled labour, joining of the bends and the suction pipes by bolting via flanges with appropriate no. of new nuts and bolts. The job also includes repair/replacement of staircase parts after extraction of the stair case approximately 200m downstream of the nallah by using JCB, tools and manual labour, repairs involve cutting the damaged parts of stair case by using welding torch, repairs/fabrication of damaged staircase by P/F of 1 no. 15 feet MS supporting channels of size 100x40x6mm. welding the retrieved steps of 2.5 feet width on MS channels, Providing and fitting of 04 no. new steps of size (2.5feet x10 inch) by welding the MS flats of size 40x6mm on MS angle (40x40x6mm) frame. Required no. of MS angle iron post to be welded on both sides of staircase to fix the 40mm dia MS pipes of appropriate length (50 feet approx.) as railings by welding to MS angle post on both sides. The stair case is to be properly fixed by way of welding of the required no. of MS angle supports to be grouted in the earth along the bank. The job also involves etching of dirt and rust from the surface of the staircase using sand paper of appropriate size, making the surface smooth and even, applying one coat of primer red oxide and two coats of paint. The complete job includes cost of material, handling of material, labour charges (skilled and semi skilled), hire charges of tools and tackles used | 1 | 01 job | 1,37,400 ₹1,37,400 | 1,35,000 ₹1,35,000 Lowest | 1,36,900 ₹1,36,900 |
Tender Value
Refer Docs
EMD Value
₹7,000
Closing Date
20 Nov 2025, 12:00 pmClosed
Executive Engg. MICD Jammu
Executive Engg. MICD Jammu
Restoration of Suction lines at Lift Irrigation Station Chajja damaged due to flash floods in the month of August 2025 along with allied works
2025_IFC_295078_1
MICD/J/40 dated 13/11/2025
Open Tender
Electrical and Maintenance Works
Item Rate
sunderbani
Please refer Tender documents.
9 documents required · 9 mandatory
₹200
Executive Engg. MICD jammu
₹7,000
29 Nov 2025
13 Nov 2025
20 Nov 2025
13 Nov 2025
20 Nov 2025
13 Nov 2025
Amount
Providing, Fitting and Fabrication of 2 Nos. MS Pipe bends of suitable angle as per site conditions from the available 200mm dia MS pipe of 1.5m overall average length with a wider curve, providing & fitting with MS Flanges 200 mm dia of standard thickness at two ends, which are properly circumferentially welded with ISI marked M.S welding electrodes, weld should free of spurts and gaps & all the slag was removed by chipping. The job also includes complete painting by way of removing the rust/dirt from the outer surface of the pipe by sanding away with emery/sand papers/steel wire brush, cleaning and making the surface even for painting then apply one coat of primer and two coats of paint on all exposed parts. P/F of 200mm dia MS pipe 13 m approximately for 2 no. suctions lines of unit I and II, by way of preparing the ends with the flanges of appropriate size to be coupled with bends. The job also involves cutting of the MS pipes as per site requirements by gas cutter. Aligning the suction lines with tools and tackles using skilled labour. Strengthening and support of MS suction pipe by installation of hooks/ clamps on either side of the MS pipe by grouting MS angles (50x50x6 mm) after excavation of pits of size(1’x1’x1.5’) and fixing with cement concrete mixture along the length of each suction pipe at 8 spots. after curing for 5 days welding the angles and suction pipe for extra strength/support to suction pipes. M.S Flanges to have suitable drilled holes to match the joining pieces & faced for perfect fit. The job included cost of welding electrodes, Oxy-acetylene gas equipment, tools & tackles required for the job, hire and carriage charges to and fro, cost of material, Cost of use of Lathe facilities for flanges, beveling of pipes by hand grinders at site wherever required etc. & labour charges for skilled & semi-skilled labour, transportation and handling charges all to be borne by the tenderer.
Providing, Fitting and installation of 2 Nos. 250 mm dia foot valves for pumping unit no. I and II by way of welding 2 No. flanges as per foot valves sample/size to 2 No. 200 dia MS suction pipe piece (provided in item no 1) and installing both foot valves on each MS suction pipe end by p/f of appropriate no. of nuts, bolts and rubber gaskets as per size. Job further involves lowering of the foot valves along with suction piece by using chain pulley block and skilled labour, joining of the bends and the suction pipes by bolting via flanges with appropriate no. of new nuts and bolts. The job also includes repair/replacement of staircase parts after extraction of the stair case approximately 200m downstream of the nallah by using JCB, tools and manual labour, repairs involve cutting the damaged parts of stair case by using welding torch, repairs/fabrication of damaged staircase by P/F of 1 no. 15 feet MS supporting channels of size 100x40x6mm. welding the retrieved steps of 2.5 feet width on MS channels, Providing and fitting of 04 no. new steps of size (2.5feet x10 inch) by welding the MS flats of size 40x6mm on MS angle (40x40x6mm) frame. Required no. of MS angle iron post to be welded on both sides of staircase to fix the 40mm dia MS pipes of appropriate length (50 feet approx.) as railings by welding to MS angle post on both sides. The stair case is to be properly fixed by way of welding of the required no. of MS angle supports to be grouted in the earth along the bank. The job also involves etching of dirt and rust from the surface of the staircase using sand paper of appropriate size, making the surface smooth and even, applying one coat of primer red oxide and two coats of paint. The complete job includes cost of material, handling of material, labour charges (skilled and semi skilled), hire charges of tools and tackles used
BEE AAR ENTERPRISES (BID ID -2644839)
M/S K S ENGG WORKS (BID ID -2642227)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.86 MB
BOQ_954839.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .