Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹75,464Accepted-AOC | L1 | Accepted-AOC accepted vide resolution no 15 dated 13.08.24 | |
| 2 | L2₹79,678.34+₹4,214.24 (5.58%)Rejected-AOC | L2 | Rejected-AOC rejected |
Tender Value
₹76,249
EMD Value
₹1,906
Closing Date
10 Jul 2024, 3:00 pmClosed
AMAL K SAJEEV,AE
Office of the Assistant Executive Engineer, Aluva Municipality
S0189/24-Electrification of Open Air Stadium near Union Bank Aluva -General Electrical Work
2024_LSGD_678721_1
E1-12358/23
Open Tender
Electrical Works
Item Rate
90 days
Aluva muncipality
Please refer Tender documents.
8 documents required · 8 mandatory
₹555
Yes
₹1,906
Yes
23 Nov 2024
3 Jul 2024
12 Jul 2024
3 Jul 2024
10 Jul 2024
3 Jul 2024
Amount
Electrification
OD37318/2024-2025:Supply , conveyance ,installation, testing and commissioning of Decorative post top LED lantern 35W , IP65 consisting die casting aluminum body for mounting LED driver and spun aluminum canopy painting pure polyester UV protected powder coated matt black finish after phosphochromate treatment , high quality polycarbonate cover , built in potted ,isolated electronic LED driver with APFC ( SMPS based constant current supply ) with lower THD, output short/open circuit protection, over voltage protection, surge voltage protection up to 10 kv with SPD and other tests, Model: Havells make RUBYPT35LED or equivalent make .
OD37320/2024-2025:Supply Conveyance, installation, testing and commissioning of 30W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled /Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV, and Aluminum pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be separately accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
OD37322/2024-2025:Supply, conveyance and erection of the following sizes of 'B' class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.80 mm dia GI pipe
OD37555/2024-2025:Supply, conveyance and erection of the following sizes of 'B' class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.50 mm dia GI pipe
OD37323/2024-2025:Supply and fixing hot press molded SMC junction box Sintex make GS-JB-1510 size 155x100x100 mm or nearest size on wall using necessary screws /bolt and nut
OD37561/2024-2025:Supply and fixing hot press molded SMC junction box Sintex make GS-JB-2014 size 200x140x95 mm or nearest size on wall using necessary screws /bolt and nut
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
90.6.5.9:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 0.75 sq mm
90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
90.6.10.3:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required32 mm
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
OD37324/2024-2025:Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required.4 X 6 sq. mm (22mm)
90.12.5.39:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 6 sq mm
90.12.7.39:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp
OD37325/2024-2025:Supply and providing 16A 8 way terminal connector on existing box and giving connections
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
OD37565/2024-2025:ISI Pipe Earthing with G.I. earth pipe 2.5 metre long, 50 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
90.16.1.10:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.25 mm GI conductor (10 SWG)
OD37573/2024-2025:Fabrication ,supply, conveyance, installation and commissioning of out door type MS sheet steel cubicle type meter board of size 600x300x250 mm or nearest size with rain shield/canopy whole board and shield made of 2 mm thick sheet and fixed on 0.90 mtr height 35x35x6 mm MS angle iron frame work including 2 coats of grey enamel paint over double coat of zincromate metal primer.
OD37584/2024-2025:Supply and fixing 63 A 2 way neutral link on SMC or DMC base and giving connections
OD37585/2024-2025:Supply and fixing 63 A Fuse unit with HRC link on existing board using suitable bolt , nut and giving connections
OD37606/2024-2025:Supply and providing DIN rail suitable for fixing MCB, Isolator, RCCB , surge protector etc. on existing board using suitable bolt, nut and washer etc.
90.16.2.5:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.50 mm dia. G.I. pipe (medium class)
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
90.10.1.6:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )8 module moulded plastic box on surface
ASHRAF T MUHAMMED
Bidder Name
JOSE P C
ASHRAF T MUHAMMED
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1055520.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .