Estimated Quantity Item Description Unit Amount in Rs.
No. in Figure In Word
Replacing old by providing new Point wiring for Light / Bell with 2-
1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 KV grade FRLS PVC insulated multi strand copper wires
up to 10 mtr length , in below type of pipe erected with 6A Modular
type switch / bell push & accessories and earth continuity of
following type, erected on PVC / Metallic/Wooden box, single Rupees Three
mounting base frame covered with textured/metallic/white front hundred Seventy
plate modules erected on / in wall / ceiling as per pipe erected, with Five Paise Seventy
necessary Lamp holder/ceiling rose / H.D.Connector as directed.(e) Two Only
in existing pipe erected flushed on wall/ceiling completeCat. III
Replacing old by providing new Half Point wiring for Light with 2-
1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 KV grade FRLS PVC insulated multi strand copper wires
up to 10 mtr length , in below type of pipe erected with 6A Modular
type switch / bell push & accessories and earth continuity of
following type, erected on PVC / Metallic/Wooden box, single
2 126 Pt mounting base frame covered with textured/metallic/white front 187.86 Pt
Seven Paise Eighty
plate modules erected on / in wall / ceiling as per pipe erected, with
necessary Lamp holder/ceiling rose / H.D.Connector as directed.(e)
in existing pipe erected flushed on wall/ceiling completeCat. III
Replacing old by providing Point wiring for FAN with 2-1.5 sq.mm
& earth wire of 1.5 sq.mm (Green) both are of .ISI marked 1.1 KV
Grade FRLS PVC insulated multi strand copper wires up to 10 mtr
length, in below type of pipe erected with 6A Modular type switch
and hum free EME step type electronic fan regulator mounted and
hundred Twenty Two
3 162 Pt accessories with earth continuity of following type erected on PVC / 522.17 Pt
Paise Seventeen
Metallic/Wooden box, single mounting base frame covered with
textured/metallic/white front plate modules erected on / in wall /
ceiling as per pipe erected. with necessary ceiling rose /
H.D.Connector as directed.(e) in existing pipe erected flushed on
wall/ceiling completeCat. III
Replacing old by providing Point wiring for Individual Plug with &
earth wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV
grade FRLS PVC insulated multi strand copper wires up to 10 mtr
length, in below type of pipe erected complete with Modular type
switch & 5 pin Plug erected on PVC / Metallic/Wooden box covered
with appropriate front plate modules erected on / in wall / ceiling as Rupees Three
per pipe erected with following type of accessories.[I] For 6A Plug hundred Eighty Eight
and 6 a switch with 2-1.5 sq.mm Cu. Wire from nearby Paise Eighty Five
switchboard/mcb db board(e) in existing pipe erected flushed on Only
wall/ceiling completeCat. III. Old 162 New
Replacing old separate point 16 Amp by Providing following type of
Modular Type Accessories mounted with PVC / metallic/Wooden
5 box, single mounting base frame covered with textured /
metallic/white front plate , modules erected with necessary
connections as per site situation directed by Engineer In charge.
A 210 Ea (9) 16 Amp. SP one way switch Cat.III . 180.79 Ea
Paise Seventy Nine
hundred Ninety Nine
B 210 Ea (10) 6/16Amp. Universal socket Cat.III. 199.98 Ea
Paise Ninety Eight
Replacing old by providing Point wiring for on board Looped Plug
with 6A Modular type switch & 5 pin socket erected on PVC / Rupees Two
6 378 Pt Metallic/Wooden box, single mounting base frame covered with 257.55 hundred Fifty Seven Pt
textured / metallic/white front plate modules erected on / in wall / Paise Fifty Five Only
ceiling with following type accessoriesCat. III.
Providing and erecting Mains with 1.1 KV grade FRLS PVC
insulated ISI marked stranded Copper conductor wire in following
7 type of pipe to be erected concealed in /flushed on wall/ceiling, with
1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of
green colour for earth continuity of following size (E) in existing pipe.
Rupees Forty Six
A 2612 Mtr (a) 2 wire 1.5 sq. mm 46.46 Mtr
Paise Forty Six Only
Rupees Sixty Two
B 1050 Mtr (b) 2 wire 2.5 sq. mm 62.62 Paise Sixty Two Mtr
Replacing old by providing and erecting Mains with 1.1 KV grade
FRLS PVC insulated ISI marked stranded Copper conductor wire in
8 following type of pipe to be erected in / on wall / ceiling with 2.5 sq.
mm copper conductor FRLS PVC insulated stranded wire of green
colour for earth continuity of following size.(E) in existing pipe
A 666 Mtr (b) 2 wire 6 sq. mm 121.20 hundred Twenty One Mtr
Paise Twenty Only
Rupees Eighty Six
B 1092 Mtr (a) 2 wire 4 sq. mm . 86.86 Paise Eighty Six Mtr
Replacing old tubefitting by Supplying and erecting LED
indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt
assembled on single MCPCB, with housing used as a heat
sink shall be made of thick sheet Steel conforming to IS:
513/CRCA/ aluminium die cast powder coated and high U.V. &
corrosion resistance with diffuser with company mark/name
160V to 270V, Power Factor more than 0.95, THD < 15%,
CCT 3000 K to 6500K,
9 Luminaire efficacy> 85 lumens/watt ,LED
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.)(A) Tube Light with integral driver.
hundred Seventy
A 120 Ea (iv) 22-24 Watts, Surge - 2KV,IP-20, conventional 4 feet Cat-lll. 373.70 Ea
Three Paise Seventy
B 60 Ea (v) 36-40 Watts, Surge-2 KV, IP-20, conventional 4 feet Cat-lll. 535.30 hundred Thirty Five Ea
Paise Thirty Only
Supplying and erecting led lamps with following wattage
capacity of 220 to 240 voltage, minimum 15000 burning hours
life, 500 V in built-surge protection,Polycarbonate diffuser, Rupees One
10 267 Ea mounting suitable for E14 / E27 / B22 lamp holders, pf >= 112.11 hundred Twelve Ea
0.5(A) LED Lamps integral type, with PC diffuser suitable Paise Eleven Only
LAMP holder (ii) 5 to 8 watts Cat-III
Replacing old by Providing & erecting Approved make Power
Saving 50 Watt Ceiling Fan with double ball bearing ISI mark Rupees One
with Condenser 230 volt A.C. 50 Hz 1200 mm sweep
11 162 Ea 1948.29 hundred Forty Eight Ea
complete having 3blades with aluminium blades with , canopy
Paise Twenty Nine
& 30 cm. down rod erected with earthing.(Make shall be Only
approved by Engineer in charge))
Replacing old by providing Decorative call bell Ting-tong box type
12 42 Ea 71.71 One Paise Seventy Ea
250 volts complete erected
Replacing old by Providing and erecting Sheet Steel powder
coated MCB distribution board - flush / surface mounted fitted
with busbar, neutral link, earth bar and DIN rail, Conforms to IS
8623-1 & 3, IEC 61439-1 & 3 without MCB to house
appropriate nos. of MCBs.(The DBs should be used of same
company of MCB to be used) suitable for(A) single phase
incoming and horizontal single phase outgoing(b) sheet steel
double door (IP-43).
A 24 Ea (iv)12 way 1492.78 hundred Ninety Two Ea
Paise Seventy Eight
B 18 Ea (v) 16 way 1680.64 hundred Eighty Ea
Paise Sixty Four
Replacing old by providing and erecting Miniature circuit
breaker single pole 6A to 25A suitable to operate on 240 V
A.C. system and having breaking capacity 10 KA to be erected Rupees One
14 408 Ea 112.11 hundred Twelve Ea
in existing box. confirming to IS 8828/1996 with ISI Mark
Paise Eleven Only
Replacing old byProviding & erecting 240 V MCB double pole Rupees Two
switch for lighting Load (B Curve) having 10 KA breaking hundred Seventy
capacity & confirms to IS : 8828 in existing box having following Eight Paise Seventy
capacity (A) 6 to 32 Amp. Cat.III Six Only
Replacing old by providing and erecting Approved make
RCCBs conforming to IS: 12640 and having sensitivity of
mA and Short Circuit withstand capacity of 10 KA and suitable
for operation on single phase 240 V,50Hz. having characteristic
16 of quick action & tripping with all advance feature & do not
incorporate any electronic component. for following Max. rating
erected as directed. (ii) 40Amps. DP Cat. III
A 42 Ea (ii) 40Amps. DP Cat. III 2235.13 Ea
hundred Thirty Five
Paise Thirteen Only
B 42 Ea (ii) 25Amps. DP Cat. III. New 1969.50 Ea
hundred Sixty Nine
Paise Fifty Only
Replacing old by providing Sheets steel powder coated hundred Seventy Six
enclosure suitable for incorporating One/Two nos. MCB. Paise Seventy Five
Replacing old by Providing and erecting ISI mark Medium class
RIGID PVC PIPES of following size complete to be erected on/in
18 wall or ceiling erected with necessary PVC fittings & Junction boxes
fixed with adhesive solution & Clamps with following dia of pipes, in
approved manner as directed
A 5058 Mtr (a)20 mm 24.24 Four Paise Twenty Mtr
Rupees Thirty Three
B 1914 Mtr (b) 25 mm 33.33 Paise Thirty Three Mtr
Supplying & erecting in earthpit of minimum bore dia. 225mm
size approved make Safe Earthing Electrode consisting Pipe-
in-Pipe Technology as per IS 3043-1987 made of corrosion
free hot dipped G.I.Pipes having Outer pipe dia of 80 mm
having 80-200 Micron galvanising, Inner pipe dia of 40 mm
having 200-250 Micron galvanising, connection terminal dia of
14 mm with constant ohmic value surrounded by highly
conductive compound with high charge dissipation suitable for
following type of applications with chamber and heavy duty
cover (A)(approved make OEM has to submit test certificate
including value of earth resistance of installation duly stamped
and signed by agency and officer Incharge has to ensure the
19 14 Ea 5842.85 hundred Forty Two Ea
value of earthing resistane mentioned in test Certificate) & Paise Eighty Five
having back filling compound of (B) Inner chemical (CCM Only
Compound)- Resistivity:- 0.2 ohm / meter testing as per IEC
62561-2017, Voltage drop:- < 1 volt at no load & dry form,
Sulphar content:- <2%(C) Back fill Compound :- Earthing
compound should be capable to retain moisture for long time
Necessary test report must be submitted by Agency.[A] For
electrical installation up to 440 V
Length of Pipe - 1 Mtr
Back filling compound - 1 Nos. of Bag of 15 Kgs.
Replacing old by Providing and erecting Steel cover as per
drawing using 16 SWG M.S.sheet of following depth, to house Rupees Three
the switch gear etc. complete with locking arrangement and Thousand Five
20 17 sq.mtr lock with duplicate keys per cupboard and door handles 3561.26 hundred Sixty One sq.mtr
erected with necessary support and painting. [One coat red Paise Twenty Six
oxide and two coat enamel paint] (A) with angle iron frame (i) Only
For 25 cms. Depth
Providing and erecting HOT deep Galvanised iron strip wire
21 10 kg 77.77 Seven Paise kg
Seventy Seven Only
Supplying and erecting HYLAM sheet on existing angle iron
22 21 sq.mtr 1156.45 hundred Fifty Six sq.mtr
frame.for following thickness(C) 6mm
Paise Forty Five
carry out RCC Core cutting- up to 100 mm dia./200mm thick Thousand One
23 34 Job Wall/beam/slab with providing PVC pipe of 3 mm thick inside 1199.88 hundred Ninety Nine Job
and necessary finishing on both ends of wall . Paise Eighty Eight
RUPEES IN WORDS : Rupees Twenty Lakh Forty Seven thousand Five hundred Thirty Seven Paise Sixty Five Only
I/We am/are willing to carry out the work at(No above rates allowed) ____________% below ___________________________________
__________________percent (Should be written in figures and words) below the tendered rates mentioned above.
Amount of my/our tender works out as under :
Put to Tender Rs. 2,047,537.65 Put to Tender Rs.
(Please strike out whichever is not applicable)
1 I/We hereby declare that I/We have visited the site, fully exquisite myself/ourselves with the local situation regarding materials and other factors pertaining
to the work before submitting this tender.
2 I/we hereby declare that I/We carefully studied the conditions of specifications and other tender documents of this work and agree to execute the same
3 A tender with any overwriting in percentage (should both in word and figures) rejected out right.
4 Insertions and/or corrections in the percentage quoted ( both in word and figures) resulting into increase in the value of the work shall be rejected outright
unless it is authenticated by the office opening the tender at the time of opening of tender.
5 Dismentaling the existing material taken by contractor as mention rates.
Signature of Contractor Deputy.Executive.Engineer Executive Engineer
C.P.Electrical R & B Sub Dn 23 C.P Electrical R & B Division
Gandhinagar Gandhinagar.
LIST OF DISMENTAL MATERIALS
Renovation to E.I. at CH-1 Type Block no - 717 ,719 , 734 , 736 & GH Type Block no - 676 , 678,679 Sector-
Name of Work :-
8 , Gandhinagar.
Sr.No. Quantity Description Of Item DM Amount of Per Amount
Cost of Old & U/S Light / Fan Point/Bell Point
tissino cu wiring.
Cost of Old & U/S Light Point tissino cu wiring for
Toilet /Bathroom / washbasin. ( Half Point ).
3 162 Pt Cost of Old & U/S tissino Individual point 5A. 6.80 Pt
Cost of Old & U/S tissino looped plug point
Cost of Old & U/S tissino Individual 16A Point
2.5sq mm Mains Cu wire
6 2612 Mtr Cost of Old & U/S 1.5 Sqmm Mains 3.78 Mtr
7 666 Mtr Cost of Old & U/S 4 Sqmm Mains 7.2 Mtr
8 162 Ea. Cost of Old & U/S Fan Regulator 8.28 Ea.
9 162 Ea. Cost of Old & U/S Fan 147.60 Ea.
10 162 Ea. Cost of Old & U/S Tubelight 14.00 Ea.
11 336 Ea. Cost of old & u/s S.P. MCB 5.00 Ea.
91 Ea. Cost of old & u/s D.P. MCB 32 Amp 13.50 Ea.
13 42 Ea. Cost of old & u/s MCB D.B. 12 Way 60.50 Ea.
14 42 Ea. Cost of old & u/s D.P. RCCB 40 Amp 128.00 Ea.
15 49 Ea. Cost of old & u/s DP Enclosure 7.50 Ea.
16 6972 Mtr Cost of old & u/s PVC Pipe 20 mm 0.72 Mtr
17 42 Ea. Cost of call bell / Buzzer 1.00 Ea.
18 17 Sq.mtr Cost of old & u/s Cup board 150.80 Sq.mtr
19 49 Ea. Cost of old & u/s DP Enclousure 7.50 Ea.
Total Cost of Dismental Materials Rs.
Say Round total Dismental Materials Rs.
Signature of Contractor Deputy Executive Engineer Executive.Engineer.
C.P Electrical R & B Sub Dn 23 C.P.Electrical R & B Division
Gandhinagar. Gandhinagar
Renovation to E.I. at CH-1 Type Block no - 717 ,719 , 734 , 736 & GH Type Block no - 676 , 678,679 Sector-8
SR.NO. ITEM MAKE LIST
1 Wiring Accessories Greatwhite , LK ( L&T ) , Indoasian
2 Wires & Cable Finolex , RR Kabal ,KEI
3 LED light Fittings, Jaquar,Wipro, LT , Philips.
4 Switchgear Legrand,Indoasian , Schneider, LT
5 Fan Orient,Bajaj, Usha.
6 Pipes Astarl , BLP , Precision
Dy.Ex.Engg Executive Engineer
C.P.Elect sub Div.23 C.P.Elect.Division
Gandhinagar Gandhinagar.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
5 - 2026-27.pdf
G S T LTR.pdf
GR.pdf
PQ CRETERIAL REGULAR.pdf
SBD Document.pdf
SCHEDULE A B DM AND MAKELIST.pdf
Download all tender documents and submit your bid