| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-Finance | ₹1.3 Cr | L1 | Accepted-Finance I |
| 2 | L2₹1.4 Cr+₹5.5 L (4.23%)Accepted-Finance CC 1 BOOTH NO 8 JANTA BHAWAN ROAD SIRSA SIRSA HARYANA 125055 | SIRSA | HARYANA | 125055 | ₹1.4 Cr+₹5.5 L (4.23%) | L2 | Accepted-Finance II |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Rejected-Technical 00 KANOONGOPURA NORTH MAHILA DISTRICT HOSPITAL BAHRAICH BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | - | - | Rejected-Technical Rejected |
Tender Value
Refer Docs
EMD Value
₹2.7 L
Closing Date
5 Dec 2019, 3:00 pmClosed
Superintending Engineer
SE.EDC.Rudrapur
Toewall/Plinth repair and other related works 250 to 400KVA. Sub Station, under EDSD Gadarpur
2019_UPCL3_21026_1
EDC(USN)34/2019-20
Open Tender
Electrical Works
Item Rate
180 days
Gadarpur
Pl. refer tender documents.
3 documents required · 3 mandatory
₹11,800
SE,EDC,Rudrapur.
₹2.7 L
3 Jan 2020
14 Nov 2019
16 Dec 2019
14 Nov 2019
5 Dec 2019
14 Nov 2019
Amount
Providing and supply of wire meash fencing around the transformers length & made of M.S.Angle from of 35x35x5mm. Wire mesh 25x25mm. Of 10 swg. M.S. wire fixing with outer mesh support of 25x5mm. M..S. Strip central support of 50x6mm. M.S. Strip of 1.85 Mtr. height with gate & locking arrangement .
Supply of Ari Circuit Breaker type complete L.T. Distribution board for 250 KVA, 400 KVA, total transformer fitted with 630 amp.breaker, ACB 4 pole MF and CT 630amp.each(For 400 KVA, transformer) inclouding microprocessor 3.1 release 45/50 KA fault indiction key lock protection true RMS sensing make (C&S-ABB-SENEMS-HPL).
Supply of Aluninium Lugs size 250 mm. suitable for 250/400KVA. Transformers.
Supply Earthing electrode having size 60mm.x3Mtr. Strip in pipe type( Fuilled with CMM Compound along with 50Kg backfill compound )
Supply of Air Circuit Breaker Stand made of M.S. Angle size 35x35x5 mm. Suitable for ACB.
Cartage of following centrally procured item from any store centre in Haldwani or Rudrapur region of UPCL to dump store, approximately distance 40 to 60 KM, including loading into private truck at store centre, unloading safely at work site /dump store and dump store to work site, average distance 01 to 30 KM. G.I. Earthing strip 35x6mm, Earthing Rod M.S. 20x2500mm & M.S. Angle of size 50x50x6mm. <XLPE Cable of size 1x240/1x400sq.mm.
Dismantling of trlansformer sub statin double Pole/Plinth with the help of chain pulleys/Belleys rail pieces depending upon the nature of job at work site.
Cleaning & levelling of all area in 11/0.4 KVA. Sub Stations.
Excavation of Earth Soil in trenches for Plinth / Toe wall. ( Both Length)
Excavation of Earth Soil in trenches for Plinth / Toe wall. ( Both Width)
Excavation of Earth Soil in pit for transformer Plinth.
Providing & laying in cement concrete 1:4:8( 1 cement, 4 fine sand & 8 brick agrregate 40mm. Nominal size) in foundation.( Both Length) including supply of all materials labour & tools & Plants etc as per direction of Engineer-In-Charge.
Providing & laying in cement concrete 1:4:8( 1 cement, 4 fine sand & 8 brick agrregate 40mm. Nominal size) in foundation.( BothWidth) including supply of all materials labour & tools & Plants etc as per direction of Engineer-In-Charge.
Providing & laying in cement concrete 1:4:8( 1 cement, 4 fine sand & 8 brick agrregate 40mm. Nominal size) in Plinth foundation. including supply of all materials labour & tools & Plants etc as per direction of Engineer-In-Charge.
Providing Class 150 brick work in 1:6 cement and find sand of 1.25 finess modules mottar in foundation & plinth including supply of all materials labour & tools & Plants etc. as per direction of Engineer-In-Charge. Ist Step. ( Both Length)
Providing Class 150 brick work in 1:6 cement and find sand of 1.25 finess modules mottar in foundation & plinth including supply of all materials labour & tools & Plants etc. as per direction of Engineer-In-Charge. Ist Step. ( Both width)
Class 150 brick work in 1:6 cement and find sand of 1.25 finess modules mottar in foundation & plinth including supply of all materials labour & tools & Plants etc. as per direction of Engineer-In-Charge. 2nd. Step. ( Both Length)
Class 150 brick work in 1:6 cement and find sand of 1.25 finess modules mottar in foundation & plinth including supply of all materials labour & tools & Plants etc. as per direction of Engineer-In-Charge. 2nd. Step. ( Both Witdth)
Class 150 brick work in 1:6 cement and find sand of 1.25 finess modules mottar in foundation & plinth including supply of all materials labour & tools & Plants etc. as per direction of Engineer-In-Charge. 3rd. Step. ( Both Length)
Class 150 brick work in 1:6 cement and find sand of 1.25 finess modules mottar in foundation & plinth including supply of all materials labour & tools & Plants etc. as per direction of Engineer-In-Charge. 3rd. Step. ( Both Width)
Providing/ repairing Class 150 Brick workin 1:6 cement and find sand of 1.25 fineness modules mortar in Plinth of height upto 1 M. & foundation including supply of all material labour & tools and plants as per direction of Engineer -In-Charge.
Providing 150 mm. thiock R.C.C. band on the top of the Transformer Plinth.
Plaster work on the Trabnsformer Plinth from all four sides in Ratio of 1:6 cement mortar. ( Long side (Both)
Plaster work on the Trabnsformer Plinth from all four sides in Ratio of 1:6 cement mortar. ( Short side (Both)
Plaster work of oe wall 1:4 Proportion. Out side.
Plaster work of oe wall 1:4 Proportion. In side.
Plaster work of oe wall 1:4 Proportion. Top side.
Earth Filling completion side of side toe wall and plinth between the two toe, and plinth.
Turfing of Sub Station completion Levelling and rammering of soil with cement concrete (1:4:8) for 0.15.m. thick.
Cleaning ,Washing & Painting of 250/400/ 500 KVA. Transformers
Mounting of 250/ 400/500 KVA. Capacity Transformer on Plinth with the help of Crain /Bellies depending upon the nature of job at work, nuetral & body fitting all accessories complete in all respect and energisation of transfomers as per direction of Engineer-In-Charge.
Installation & Commissioning of Chemical Earthing by digging pit/bore of 6'' size insert earthing electrode 3 Mtr. Deep from ground level & filling of earthing & filled it with backfill compound testing of earth value with earth tester complete in all respect as per direction of Engineer - In-Charge.
Fixing of Wiremesh fencing & fencing with nuts & bolt with two wall length Work C.C. 1:4:8 for excavation of toe wall.
Installation of ACB L.T. Distribution Board complete with earthing strip proper welding and eartghing inall respect i.e. disconnection of exising cable from DTR terminal and metering cubicals, fixing of new additional cable in ACB L.T. DB connectiing DTR metering complete as it was and upto DTR terminal connection using alluminium lugs of proper size ( Lugs will be provided by the supplier) as per required the site and narrated by the Engineer incharge of the work of ACB .
Laying of LT, XLPE cable with all connections, Lugs etc.
Painting of Wiremesh support complete with one coat of red oxide primer & two coat green standard paint .
Whitewash of Toe Wall & Transformer Plinth.
Erection of M.S. Earthing rod 20x2500 mm. For earthing of supports as per RESPO drawing No. RES-12 including driving earth rod 2.5 Mtr. Deep below tround level connected to support with G.I. earthing strip fixing of clamp wigth bolts & nuts earthing lug etc, including all other material and labour T&P etc required for proper completion of work ( G.I. Earthing strip 35x6, and earthing rods 20x2500mm. will be provided by the department )
M.S. Name Plate for transformer of size 400x500mm2
Back Cartage of wire mesh scrap etc.
ASHOK KUMAR AND CO
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .