| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.3 LAccepted-AOC 18 837 KILIYARAA HOUSE PERUMPADAPPU PALLURUTHY PO KOCHI 682 006 | KOCHI | ERNAKULAM | KERALA | 682006 | L1 | Accepted-AOC BEING LOWEST TENDERER | |
| 2 | L2₹38.1 L+₹57,529.25 (1.53%)Rejected-Finance | L2 | Rejected-Finance Rejected being not lowest
Rejected being not lowest | |
| 3 | L3₹38.3 L+₹75,139.25 (2.00%)Rejected-Finance NIVAS S J NIVAS 26 1798A CHALANCHERY ROAD MAMMAJIMUKU THEVARA KOCHI 682 013 | KOCHI | ERNAKULAM | KERALA | 682013 | L3 | Rejected-Finance Rejected being not lowest
Rejected being not lowest | |
| 4 | L4₹39.5 L+₹2.0 L (5.26%)Rejected-Finance | L4 | Rejected-Finance Rejected being not lowest
Rejected being not lowest | |
| 5 | L5₹41.2 L+₹3.7 L (9.84%)Rejected-Finance | L5 | Rejected-Finance Rejected being not lowest
Rejected being not lowest |
Tender Value
₹49.7 L
EMD Value
₹99,400
Closing Date
17 Mar 2021, 6:00 pmClosed
GARRISON ENGINEER (NW) KOCHI
KATARIBAGH, NAVAL BASE POST, KOCHI-682004
AUGMENTATION OF SECURITY INCL ADDN/ALTN OF BOUNDARY WALL, PROVN OF GATE AND ASSOCIATED WORKS AT COMMAND INTELLIGENCE OFFICE AND CERTAIN OTHER SANCTIONED WORKS UNDER GE(NW) KOCHI AT NAVAL BASE KOCHI
2021_MES_423414_1
GE(NW)KOCHI/8276/E8
Open Tender
Civil Works
Item Rate
180 days
KOCHI
AUGMENTATION OF SECURITY INCL ADDN/ALTN OF BOUNDARY WALL, PROVN OF GATE AND ASSOCIATED WORKS AT COMMAND INTELLIGENCE OFFICE AND CERTAIN OTHER SANCTIONED WORKS UNDER GE(NW) KOCHI AT NAVAL BASE KOCHI
7 documents required · 7 mandatory
₹500
GE 9NW) KOCHI
₹99,400
Yes
31 Oct 2021
18 Feb 2021
19 Mar 2021
18 Feb 2021
17 Mar 2021
4 Mar 2021
Amount
Excavating in post holes (or similar holes) in soft/loose soil, each not exc 0.50CuM, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25cm, watering and removing surplus soil to a distance not exc 50M and making good the surface complete all as specified and directed.
M&L for plain cement concrete type D-2, 1:4:8 (40mm graded aggregate) as in foundations, filling and mass concrete all as specified and directed .
M&L for plain cement concrete type C-2, 1:3:6 (40mm graded aggregate) as in foundations, filling and mass concrete all as specified and directed .
M&L for plain cement concrete type B-2, 1:2:4 (40mm graded aggregate) as in foundations, filling and mass concrete all as specified and directed .
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified abd directed.
S&F prepainted galvalume zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws all as specified and directed.
M&L for mild steel tubes as in posts including special shaped washters etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240, all as specified and directed.
M&L for mild steel tubes as in tubular trusses including special shaped washters etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240, all as specified and directed.
M&L for preparation of new or previously untreated steel surface exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer all as specified and as directed
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed
M&L for pre-cast cement concrete block masonry in Type C1, 1:3:6 (20mm graded aggregate) with solid blocks, exc 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed.
M&L for rendering 15mm thick on brick work or concrete surfaces in cement mortar 1:4 finished even & smooth (without using extra cement.) all as specified and directed .
M&L for rendering 15mm thick on brick work or concrete surfaces in cement mortar 1:6 finished even & smooth (without using extra cement.) all as specified and directed .
M&L for preparation of new plasetered or unplastered surfaces of walls & applying two coats of cement base paint over a coat of alkali resistant primer
M&L for preparation of old treated plasetered surfaces of walls by complete removal of existing treatment & applying two coats of cement base paint over a coat of alkali resistant primer
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc.not exc 10 sq m on plan and not exc 1.5 m in depth and getting out in soft/loose soil complete all as specified
Returning, filling in, including spreading, levelling, watering and well ramming soil in layers n exc 25 cm thick all as specified and directed.
Removal of surplus soil to a distance exc 250 m and n.exc. 500 m and depositing where directed at a level n.exc. 1.5 m above the starting point all as directed by Engineer - In - Charge.
Removing excavatged materials to a dist n.exc 50- m and depositing where directed at a level n.exc 1.50 m aabove the starting point.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for fair finished surfaces
M&L for RCC Type B1 1:2:4 (20mm graded aggregate) nominal mix in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, all as specified and directed. (Reinforcement will be measured and paid separately).
Formwork to sides of pillars, posts, struts, piers, columns and stanchions, square, rectangular or polygonal in shape, for rough finished surfaces of concrete, all as specified and directed.
M&L for RCC Type B1 1:2:4 (20mm graded aggregate) nominal mix in Columns, pillars, piers, posts and struts, all as specified and directed. (Reinforcement will be measured and paid separately).
S&F for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders complete all as specified and directed.
S & F mild steel framed work as in sliding gates of angle or other section with gusset plates, rails, braces etc completed drilled for fixing steel sheeting or other covering doors etc, incl hooks or hinges or steel hanging door fittings, running rials and guides conforming to Fe gde 410-W, Gde E-250.
S&F MS angle iron as in parts &sturts in fencing including cutting tops to shape as directed,drilling holes ,noticing for wire etc flat iron fillets ,MS bars etc for securing chain link complete all as specified and as directed
S& F in repairs, galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails, straining bolts including securing or tying at crossings with and provision of galvanised mild steel wire staples or steel pins etc as specified and directed
Dismantling floor hearth or wall tiling including cement mortar bedding removing unserviceable tiles to store and rubbish of the permises complete all as specified and directed by Engr-in-Charge.
Taking down chowkat with shutters (without taking off shutters from the frames) n exc 1.5 Sqm each all as directed.
M&L for non-skid ceramic coloured tiles, 7 to 8 mm thick (square/rectangular), area of each tile exceeding 0.06 SqM but not exceeding 0.11 SqM, laid in floors etc, over and including CM 1:6, 15mm thick screed bed, set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and as directed.
M&L for glazed ceramic coloured tiles of size 600x300x7mm thick on vertical surfaces, over and including CM 1:4, 10mm thick backing coat, set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and as directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5.0mm plain colour PVC sheet reinforced with mild steel square tube, and fixing in opening as per specifications and drawing, complete all as specified and as directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width strucks inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either to side and as gap insert for top rail & bottom rail panelling of plain colour PVC sheet to be fitted in MS frame welded/sealed to stiles and rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as specified of drawing.
S&F 100mm long stainless steel butt hinges for PVC door, all as specified and directed.
S & F 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified
S&F 150mm long aluminium anodised handle, cast type, all as specified
S&F powder coated anodised aluminium frame work for doors, windows, ventilators and partitions with one or more rebates including joining cleat for fixing etc.complete all as specified & directed.
S&F aluminium anodised window & ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55Kg/RM including necessary jointing cleats, glazing clips, rubber packing, anodised aluminium fitings such as peg stays 150mm long (1No), hinges type B21 100mm long (2Nos), suitable handle (1No) complete all as specified and directed.
S&F 5.5mm thick sheet glass,ordinary quality and glazing with oil putty in square n.exc 0.50 sqm in each pane, all as specified and directed.
S&F Solar control film 50 micron reflective type sticked to glass panes as per manufacturer's instructions and as directed.
S&F PVC (SWR) 'P' or 'S' trap, 110mm dia complete, all as specified and directed.
S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe), all as specified and directed.
S&F in repairs Vitreous china superior coloured wash down water closet pedestal pattern including plastic seat cover complete all as specified and directed.
S&F 10 litre capacity PVC flushing cistern low level in repair white colour with inlet ball valve float and handle incl brackets, all as specified and directed.
S&F hand shower (health faucet) with 8 mm dia 1 Mtr long felixible tube and wall hook make PRAYAG Cat No BHS 48 & BEA 81, all as specified and directed.
S&F in repair vitreous china wash basin white flat back size 580 x 450 plug excluding taps, waste , chain and plug and porcelain stopper but including brackets, all as specified and directed.
S&F 15mm Pillar taps (fancy type), cast copper alloy, with capstan heads,chromium plated,screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, all as specified and directed,
S&F aluminium anodised tubular towel rail 20 mm dia,D type 60cm long, all as specified and directed.
S& F fancy Bib taps, Chromium plated with crutch or butterfly handle, sc-rewed down, screwed for iron pipe or for brass ferrule and fixed, all as specified and directed.
S & F 32 mm dia Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed, all as specified and directed.
S&F High density poly-ethylene pipes (HDPE) of size 15mm dia and of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc., all as specified and directed.
All as per item No.49 above, but of size 20mm dia
M&L for Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth , all as specified and directed.
S&F PVC (SWR) pipes, 110mm dia, single socketed in any length with rubber ring joints laid in trenches or in floors complete, all as specified and directed.
S&F 150mm PVC (SWR) pipes single socketed in any length with rubber ring joints with wall and pole including clamp for PVC brackets complete all as specified and directed.
S&F PVC SWR bends 110mm any radius with access door, all as specified and directed.
S&F PVC connection 15mm size with PTMT nuts of 600mm length, all as specified and directed.
S&F towel ring of PTMT fixed with and including plated brass screws and wooden/plastic cleats, all as specified and directed.
Taking down cement plaster of any description, all as specified and directed.
M&L for rendering 10mm thick on brick work or concrete surfaces in cement mortar 1:6 finished even & smooth (without using extra cement.) all as specified and directed .
M&L for preparing newly plastered wall surfaces and applying three coats of white wash all as specified and as directed.
M & L for reinforced cement concrete Type B1 1:2:4 (20mm graded aggregate) as in precast cover slab for manhole, set in CM 1:6 complete in all as specified and directed. Note: Reinforcement will be measured and paid separately.
M & L for reinforced cement concrete Type C1 1:3:6 (20mm graded aggregate) as in precast cover slab for manhole, set in CM 1:6 complete in all as specified and directed. Note: Reinforcement will be measured and paid separately.
M & L for reinforced cement concrete Type B1 1:2:4 (20mm graded aggregate) as in precast cover slab for manhole, set in CM 1:4 complete in all as specified and directed. Note: Reinforcement will be measured and paid separately.
M&L for plain cement concrete type D-2, 1:4:8 (40mm graded aggregate) as in surface channels and drains, all as specified and directed .
M&L for plain cement concrete type B1, 1:2:4 (20mm graded aggregate) as in surface channels and drains, all as specified and directed .
M&L for pre-cast cement concrete block masonry in Type B1, 1:2:4 (20mm graded aggregate) with solid blocks, exc 10 cm in width and setting in cement mortar 1:4 complete all as specified and directed.
M&L for pre-cast cement concrete block masonry in Type C1, 1:3:6 (20mm graded aggregate) with solid blocks, exc 10 cm in width and setting in cement mortar 1:4 complete all as specified and directed.
S&F for Mild steel TMT bars, 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for PCC 1:3:6, type C2 using 40mm graded stone aggregate as in concrete bed to drain pipes of 150mm bore including packing under and haunching against sides of pipe after they are laid and tested, all as specified and directed.
Removal of surplus soil to a distance n.exc. 50 m and n.exc. 1.5 m above the starting point as directed by Engineer - In - Charge.
M&L for hume pipe septic tank 50 users capacity incl AC vent pipe, earth work excavation in soft / loose soil erecting hume pipe septic tank in position, PCC 1:3:6 and all other accessories required such as vent cowl etc and making good the disturbed surface and removing surplus soil and old u/s septic tank, complete incl connecting to the sewer line etc complete (drg No TD/2/86 sheet 1/1 dt 22.11.2000)
M&L for hume pipe septic tank 25 users capacity incl AC vent pipe, earth work excavation in soft / loose soil erecting hume pipe septic tank in position, PCC 1:3:6 and all other accessories required such as vent cowl etc and making good the disturbed surface and removing surplus soil and old u/s septic tank, complete incl connecting to the sewer line etc complete (drg No TD/2/86 sheet 1/1 dt 22.11.2000)
Extra for forming fair finished channel or drain 30cm girth (inner ginth) in cement concrete using extra cement incl forms, moulds, stops etc complete all as specified and directed.;
M &L for MS work such as rungs, handles to manholes,etc.
Supply only integral water proofing compound
Taking down old stop valve,stop cock,bib cock ,from existing position including all fittings all as specified and as directed.
S&F on wall / ceiling (concealed) CPVC pipe 25 mm dia SDR 11 & plain SDR 11 fittings.Make:- Supreme
S&F on wall / ceiling (concealed) CPVC pipe 20mm dia SDR 11 & plain SDR 11 fittings.Make:- Supreme
S&F Gunmetal globe or gate valve 25 mm dia iron wheel head screwed both ends for PVC pipes incl taking out old.
Supply & fix stop valve (angle type) cast copper alloy high pressure,screwed for 15mm dia CP fancy type (Half turn) .Make:-CERA/JAGUAR/HINDWARE
S&F bib tap cast cooper alloy fancy type screwed for iron pipe 15mm dai CP.
S&F Two way bib tap with wall flange of size 15mm dia (Make- CERA Cat No. F 2004163 or equivalent make of Jaguar/Parryware) complete all as specified and directed including takind down
S&F Health faucet ABS body with wall hook & 1Mtr SS braided flexible tube complete. (Make-CERA Cat No- Cera F 8030102 ) all as specified and directed including taking down old one
S&F shower rose with shower arm CP swivel type of bore 15mm, face dai 125mm.
Taking down old unserviceable GI tubing of size 20mm
Taking down old unserviceable GI tubing of size 25mm
Supply and fixing in replacement of Rotational mouldede polyethylene water storage tanks (cylinderical vertical with closed top) hoisted & fixed in position of capacity 500 liters COMPLETE ALL AS SPECIFIED
Supply & fixing of PVC connections 15mm dia size with PTMT nuts of length 450mm and taking down old one complete with brass union on both sides to suit 15mm GI pipe.
M & L framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290 (Gde-E-165) complete all as specified
M&L for 75 mm thick plain cement concrete type D-2, 1:4:8 (40mm graded aggregate) as in sub base of floor all as specified and directed .
M&L for Coarse aggregate for granolithic floors graded from 12.5mm to 4.75mm under floors or in foundations spreading and levelling in layers n exc. 0.5 cm thick incl well ramming including watering as required complete all as specified and directed.
M&L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade with grey cement and pigment complete all as specified and directed.
M & L for painting on Brick, Stone, concrete, Asbestos cement or plaster surfaces with two coats of Synthetic enamel (ordinary tint) over a coat of Priming paints plaster coat for new or previously untreated Surfaces of any description over 10cm girth or width, not otherwise described and including preparation of surfaces complete
Demolition of RCC of any description and in any position not otherwise specifically provided for nex 15 cm below or aboue GL
M&L for RCC M 30 as in lintel bands (using 20mm graded stone aggregate)(Reinforcement and form work will be measured and paid separately).
M&L for Providing precast cement concrete louvres and jallies, 50 mm thick (measured solid) type B0 1:2:4(12.5 mm graded aggregate), including all mouldings but excluding frame .
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings complete and making good disturbed surfaces of walls, floors, etc complete all as specified.
Supply and fixing of heavy duty exhaust fans AC single phase 230/ 240 V of size 300 mm sweep all as specified and directed model -turbojet SP of Havells/Usha/VGuard
M & L for Surface point wiring with 1.5Sq mm PVC insulated unsheathed multistranded single core copper conductor FRLS, ISI marked cable in and including ISI Marked, medium grade, non metallic, Fire Resistant PVC Casing & Capping and all accessories, medium grade PVC surface Box with top cover plate, 1.5Sqmm PVC insulated unsheathed multistranded single core copper conductor FRLS, ISI marked cable as earth continuity conductor and making good disturbed surfaces, applying distemper / Emulsions matching to the existing colour / quality of walls / floor / ceiling etc all as specified for One light point controlled by one switch.
S & F switch piano flush type, 5A, AC, 240V, one way ISI Marked all as specified.
S & F Ceiling rose surface Bakelite 65x50mm, 3 terminals, AC, 240V, ISI Marked and as specified.
S&F heavy duty exhaust fan AC single phase 230/240 V of size 300 mm sweep all as specified and directed. (Make: Turbo Force SP of Havells or equivalent make of Usha/V Guard).
S&F tube light fitting 1x20W with T8 LED tube with aluminium extrusion heat sink for optimum performance with high luminous efficiency and batten prewired suitable for use with LED tube with concealed accessories complete including taking down old one complete all as specified and directed. (Make: Cat Part No.TMC501 P 20W 1xT LED P3241+ESSENTIAL LED TUBE 20W 1200MM 20W 865 T8 IND of Philips or equivalent make of Havells/Wipro.
Material and labour for submain wiring with 2 runs of 6 Sqmm single core,PVC insulated, unsheathed, multistranded copper conductor FRLS cable 1100 volts grade drawn through PVC caping and casing with all accessories on surface, one run of 6 Sqmm cable single core PVC insulated, unsheathed, ,1100 Volts grade multistranded copper conductor FRLS cable as earth continuity conductor and connecting with suitable size thimble complete all as specified and directed. Note:-Three runs of 6 Sqmm size PVC copper cable and one run of PVC caping and casing shall be measured as one unit length.
Material and labour for submain wiring with 2 runs of 2.5 Sqmm single core,PVC insulated, unsheathed, multistranded copper conductor FRLS cable 1100 volts grade drawn through PVC caping and casing with all accessories on surface, one run of 2.5 Sqmm cable single core PVC insulated, unsheathed, ,1100 Volts grade multistranded copper conductor FRLS cable as earth continuity conductor and connecting with suitable size thimble complete all as specified and directed. Note:-Three runs of 2.5 Sqmm size PVC copper cable and one run of PVC caping and casing shall be measured as one unit length.
S & F in repair Sheet Metal Enclosure for MCB DB, SPN, 8 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified and directed.
S & F in repair Sheet Metal Enclosure for MCB DB, SPN, 4 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified and directed.
S&F in repair, MCB SPN, 6-32 amp, 240 volts, 10 KA , C curve including all electrical connection all as specified and as directed.
S&F in repair, MCB SP, 6-32 amp, 240 volts, 10 KA , C curve including all electrical connection all as specified and as directed.
M & L Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanized iron wire 4mm dia as earth up to 7.5 m distance and connected by means of bolts, nuts, checknuts and washers of galvanised iron or steel all shown in electric plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including provision of necessary excavation and earth work in any type of soil, PCC pit , RCC cover 50 mm thick, reinforced with 8 mm dia TMT bars both ways @ 10 CM c/c , 20 mm bore medium grade watering pipe, water funnel, 40 mm bore GI medium grade protection pipe, common salt, charcoal dust, returning, filling in of soil, removal of spoil to a distance not exceeding 50 mtr including taking out old ones and testing on completion complete all as specified. Note :- (i) The unit rate includes for protection pipe and earth lead upto 7.50 Mtr. (ii) Earth lead beyond 7.50 Mtr length shall be measured and paid separately.
Supply and Laying inreplacement of XLPE insulated galvanised steel strip or wire armoured elctric power cable with stranded aluminium conductor 1100 V grade of size 25 sqmm 4 core after cutting to required length with necessary glands, nuts, bolts, and lugs including taking down old cable complete all as specified and directed (Fixing on wall)
All as per item No 1 here in above but cable of size 185 sqmm 3.5 core
Cutting existing road/hardstand of any type by using crow bar chisel uprto a depthof 30 cm for laying GI pipe including making good the surface by returning filling watering ramming in layers 150 mm thick PCC 1:2:4 over 200 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exc. 25 cm thick complete all as specified and directed by Engineer-in-Charge.
M&L for GI tubing light grade (ISI marked) with all fitting/acessories for protection of cable on pole/wall and under road crossing including clamps, nut bolt etc all as specified and directed of size 40mm dia (make: prakash surya/jindal/TATA)
M & L PCC (1:4:8) type D-2 (using 40mm graded caushed stone aggregate) as in foundation of poles and stay etc including form work complete all as specified.
S&F in replacement LED Flood light fitting Secures 30 Watt, energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium iP65 flood light, suitable for highlighting architectural facade and general purpose lighting, heat resistant, toughened glass with frame with IP 66 Protection, including taking down the old one ,Complete all as specified and as directed . Make : Havells Cat Part No.JETAQUANTOPLUSFLP30WLED757SYM or in Crompton, Surya
S&F in replacement , Garden Light fitting, 15 Watt LED Decorative Post top for 360° indirect light with IP 65 protection Resistant to impact and corrosion. Glare-free new generation, post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power leds as light source ,including taking down the old one Complete all as specified and as directed. Make :- Havells Part No RUBYMINIPT15WLED830PSYMTOPC or in philips, Bajaj, Wipro, Jaguar
Supply and fixing, in replacement , junction box made of glass fibre reinforced and transparent poly carbonate of size 126x228x111, KV PC 8104 with IP 65 protection including MCB SP, 10 Amps 1 No and suitable size clamps fixing for pole/in pcc foundation etc,including taking down the old one,all as specified and as directed. Make :-Hensel
M&L PVC insulated copper conductor 3 core 2.5 sqmm cable to be drawn inside the pole , including taking down of old one, all as specified and as directed.
Supply, installation, testing and commissioning in replacement of L.T Feeder Pillar box suitable for 415 Volts, 3 Phase 4 Wire, 50 Hz AC Supply System confirming to IS:8623/93, Outdoor type floor mounting along with factory made type panel weather proof, vermin proof, fully ventilated and fabricated out of MS CRCA sheet of 3mm thick having aluminium bus bar of rating 500 Amps, three phase and one neutral fixed on insulator and bus bar insulated by coloured heat shrinkable sleeves. The panel shall be front and back openable and having inner & outer shells. The inner shell duly compartmented for each control gear, including Powder coating internally and externally the entire steel surfaces. All the cover shall be provided with suitable locking arrangements. The size of the outer shell should not be less than 1100mm x 1100mm x 450mm, mounted on angle iron stand of minimum 60 cm height from the PCC grounting made out of angle size 50 X 50 X 6 mm grouted in PCC 1:3:6, including accommodating the following controls gears.
(A) IN COMING (a) MCCB , 4 pole 315 Amps, 36 KA breaking capacity -01 No (b) RYB LED indicating lamp panel mounting type (Set of 3) - 01 Set (c) VAF + PF Meter with CT & control MCBs- 01 set (B) OUTGOING (a) MCCB, 3 pole 125 Amps, 25 KA breaking capacity - 01 Nos (b) MCCB, 3 pole 100 Amps, 25 KA breaking capacity - 02 Nos (c) MCCB, 4 pole 63 Amps, 16 KA breaking capacity - 01 Nos
S&F Tubelight fitting 1 x20 w ,with T 8 LED tube with aluminium Extrusion heat sink for optimum performance with high luminous efficiency and batten pre wired suitable for use with LED tube with concealed accessories complete. including taking down old one complete all as specified and directed. Make: Philips Cat part No;TMC501 P 20W 1XT LED P3241+ESSENTIAL LED TUBE 20W 1200MM 20W 865 T8 IND/HAVELLS/WIPRO
M.J. Leons and sons
SUKU CONSTRUCTIONS
M/s ANTONY THOMAS AND CO
THOMSONS CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .