BARC(V) main site ,Atchutapuram ,Visakhaptanam.
Internal Electrification and uninterrupted power supply arrangement of substation building near assembly workshop building of HFRR and MSBRDF at BARC(V) main campus, Atchutapuarm near Visakhapatnam , A. P.
2023_BARC_753601_1
BARCF-V/ESS-V/2023/11
Open Tender
Electrical Works
Item Rate
150 days
BARC(V) main site, Atchutapuram, Visakhaptanam.
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹1 L
30 Jun 2023
17 May 2023
20 Jun 2023
17 May 2023
12 Jun 2023
31 May 2023
18 May 2023 - 29 May 2023
Amount
600 X 600 LED Surface mounted lighting fixture.
300 X 300 LED Surface mounted lighting fixture
22W LED Batten Type Surface mounted lighting fixture.
40W LED Batten Type Surface mounted lighting fixture.
5W LED Surface mounted mirror lighting fixture
34W LED Suspended Lighting Fixture
1200mm sweep BLDC Ceiling fan with regulator & safety wire.
200mm diameter PVC Exhaust fan with automatic shutter.
18 inch diameter metal exhaust fan with metal louvers.
Supply of nominal insulating mat 2.5 mm +/- 10% thick and 1 m width conforming to IS 15652: 2006 and meeting the requirement of IS: 5216 (Part 1, 2 &3), IS 8437, IEC-479 Pub-1 & as per of IS: 15652 and suitable for class - B upto 11 kv, Make -Electromat or equivalent OEM
MS item includes various sizes of L angle, C channel, metal sheet of various thickness. These items will be used for various purposes like creating support structure for the cable trays, checkered plates for covering the trenches. Fabrication including Cutting , welding , Red oxide painting and enamel paint, cost of welding rod is to be included in quoted rates.
Supply, installation, testing and commissioning of 450 mm width Cable Tray with earth strip as per tender specification and drawing
Cable end box suitable for TPN DB of 8 way
7 segment phase segration,TPN DB of 4 way with acryllic door
Cable end box suitable for TPN DB of 4 way
6 /10/16 amp SP C type
16 amp 4P B type MCB
40 amp 4P C type MCB
40 amp 2P RCCB of 30 ma sensitivity
6/16 Amp universal socket
6 Amp 1 modular Switch with indication light
1 modular weather proof (IP55) switch box & adaptor with pvc membrane containing 1 number of switch. (Equivalent to Legrand IP55 Plexo box with PVC membrane.)
16 Amp 1 modular Switch with indication light
16 Amp starter for controlling of AC points
1 module/2 module cover plate with frame
3 module cover plate with frame
4 module cover plate with frame
6 module cover plate with frame
12 module cover plate with frame
Point wiring with 1.5 sq mm wire. Each wiring circuit consist of phase wire, neutral wire, earth wire. The average length of each wire(i.e. phase, neutral & earth) is (5±2) meter individually. Wiring in same flush box is not consided to be separate wiring point
Point wiring with 1.5 sq mm wire. Each wiring circuit consist of phase wire, neutral wire, earth wire. The average length of each wire(i.e. phase, neutral & earth) is (15±5) meter individually. Wiring in same flush box is not consided to be separate wiring point
Point wiring with 1.5 sq mm wire. Each wiring circuit consist of phase wire, neutral wire, earth wire. The average length of each wire(i.e. phase, neutral & earth) is (30±7) meter individually. Wiring in same flush box is not consided to be separate wiring point
Point wiring with 1.5 sq mm wire. Each wiring circuit consist of phase wire, neutral wire, earth wire. The average length of each wire(i.e. phase, neutral & earth) is (50±10) meter individually. Wiring in same flush box is not consided to be separate wiring point
Point wiring with 2.5 sq mm wire. Each wiring circuit consist of phase wire, neutral wire, earth wire. The average length of each wire(i.e. phase, neutral & earth) is (20±5) meter individually. Wiring in same flush box is not consided to be separate wiring point
Point wiring with 2.5 sq mm wire. Each wiring circuit consist of phase wire, neutral wire, earth wire. The average length of each wire(i.e. phase, neutral & earth) is (10±3) meter individually. Wiring in same flush box is not consided to be separate wiring point
Point wiring with 4 sq mm wire. Each wiring circuit consist of phase wire, neutral wire, earth wire. The average length of each wire(i.e. phase, neutral & earth) is (25±5) meter individually. Wiring in same flush box is not consided to be separate wiring point
Supply and installation of metallic modular boxes flush box of 1M/2M/3M
PVC Conduits-25mm 1.8 mm (MMS) including coupler, T joints bends as per site condition
25 mm deep junction box (1/2/3/4 way)
75 mm deep junction box (1/2/3/4 way)
100 mm deep junction box (1/2/3/4 way)
2 Ton 5 star Inverter Split Air Conditioner along with stabilizer.
Supply, installation, testing and commissioning of 9U height wall mounted rack with accessories (a) hinged glass door (b)1 No. of 24 port cat-6 UTP loaded jack panel with cable manager (c) light (d) cooling fan (e) four outlet power distribution box (f) factory crimped 3 feet UTP, Cat-6 patch cord (24 Nos.)
Supply, installation,testing and commissioning of Cat-6 UTP cable. The cable shall be terminated in the existing jack panel/ information outlets.
Supply, installation, testing and commissioning of 0.5mm annealed bare copper conductor, two pair with PVC insulated telephone cable.
Supply,Installation, Testing and Commissioning of 20 pair Krone terminal strip ( 2 Nos of 10 pair trips) with suitable size of MS box with dust cover for terminal strips.
Supply and installation of RJ-45 Cat 6 computer socket module.
Supply and installation of RJ-11 Telephone socket module
Cat6 UTP 5 mtr., factory crimped patch cord
supply installation of Earth resistance tester as per tender specification
Metal sheet box with dimensions (200mmX200mmX100mm). The (200mmX200mm) face of the box shall be openable. The box shall have provisions of knockout of cable glanding with fixing arrangement on wall using nut & bolts. The box shall be made up of seven tank treated, powder coated, oven baked, 3mm thick sheet.
Supply and Installation of 16 sqmm copper flexible single core wire with flame retardent, PVC compound, green colored insulation.
Supply Installation testing of 5KVA UPS with battery bank as per tender specification
QUALITY ENGINEERING SERVICES
MONITOR ENGINEERING WORKS
MEPF INFRA
Shantha Electricals and Engineers Pvt Ltd
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .