Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹13.2 L
Closing Date
17 Nov 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
HOD (Procurement)
Appointment of Maintenance Contractor for Rajkot and Bhavnagar Bases of GTL Gas Grid
355886
GTL/PROC/2026/10/O/510
Open
AMC/Maintenance Contracts
Works
Gandhinagar
11 documents required · 10 mandatory · 1 optional
₹10,000
GSPL Transmission Limited
₹13.2 L
17 Oct 2026
17 Oct 2026
17 Oct 2026
17 Nov 2026
17 Oct 2026
Details of Pipelines Under Rajkot Base(Rajkot Region)
Sr. No. Pipeline Section Pipeline length (KM) Pipeline Dia (Inch) Pipeline Thickness (mm) Pipeline Material Specification Design Pressure (Bar.g) Commissioning Date Remarks
1 Anand Rajkot Pipeline-B 101.42 24 11.1, 14.3, 17.5 24" API 5L GR X65 95 15.01.2007
3 Bhodigodi Ambardi Pipeline 46.98 12 6.4, 7.9, 8.7 12" API 5L GR X 65 98 14.09.2016
4 Rajkot Jamnagar Pipeline 109.164 30 13.3, 15.9, 20.6 30" API 5L GR X70 98 25.03.2009
Details of Pipelines Under Anjar Sub- base
1 MMPL (MORBI MUNDRA) 128.938 18 8.7/10.3 API 5L Gr. X-65 95 barg 20.01.2010
4 AMPL (ANJAR-MUNDRA) 67.326 36 15.47, 18.56, 23.2 API 5L Gr. X-70 98 barg 22.03.2019 (Ratatalav to SV-2 & 29.01.2020 (SV-2 to RT-Mundra)
5 WELSPUN SPURLINE 4.909 12 7.1, 7.9, 8.7 API 5L Gr. X-65 95 barg 20.01.2010
6 EURO SPURLINE 4.206 8 6.4/7.9 API 5L Gr. X-52 50 barg 16.03.2010
7 ANJANTA SPURLINE 6.627 12 6.4/7.9 API 5L Gr. X-52 50 barg 31.08.2010
8 METRADE SPURLINE 7.231 12 6.4, 7.1, 7.9, 8.7 API 5L Gr. X-52 50 barg 13.10.2010
9 METRADE SPURLINE 0.246 8 6.4 API 5L Gr. X-52 50 barg 13.10.2010
10 METRADE SPURLINE 0.386 8 6.4 API 5L Gr. X-52 50 barg 13.10.2010
11 METRADE SPURLINE 0.698 8 6.4 API 5L Gr. X-52 50 barg 13.10.2010
12 SUMANGLAM SPUR 4.489 8 6.4/7.9 API 5L Gr. X-52 98 barg 15.10.2010
13 ELECTROTHERM SPURLINE 9.551 8 6.4/7.9 API 5L Gr. X-52 98 barg 28.03.2012
14 CHIMIQUE SPURLINE 1.62 6 6.4 API 5L Gr. X-52 49 barg 22.01.2013
15 PARLE SPURLINE 5.433 6 6.4/7.9 API 5L Gr. X-52 98 barg 08.07.2015
16 RAMACYLINDER CONNECTIVITY 0.019 4 6.4/7.9 API 5L Gr. X-52 49 barg 22.08.2016
17 CHROMENI SPUR 1.279 8" 7.9, 9.5 API 5L Gr. X-52 98 barg 22.03.2019 (36"x8" Tee to UG valve) & 28.03.2019 (UG valve to Chromeni)
18 SNF SPUR 2.957 8" 6.4 API 5L Gr. X-52 98 barg 14.02.2020
Details of Pipelines Under Bhavnagar Base
1 Darod - Jafrabad-A 101.77 24 11.9/14.3 API 5L GR X 65 PSL 2 98 25.03.2011
3 Botad Spurline 23.348 8 6.4/7.9 API 5L GR X 52 PSL 2 98 21.12.2011
4 Bhavnagar Spurline 14.377 12 6.4/7.9/8.7 API 5L GR X 65 PSL 2 98 10.01.2012
5 Tana Amreli Pipeline 75.156 12 6.4/7.9 API 5L GR X 65 PSL 2 98 05.06.2012
6 Pipavav Gundala Pipeline 45.531 18 8.7/10.3/11.9/12.7 API 5L GR X 65 PSL 2 98 17.01.2020
7 Chhara LNG Connectivity Pipeline 88.722 36 15.47/19.05/23.83/26.97 API 5L GR X 70 PSL 2 98 18.03.2025
8 SWAN FSRU Connectivity Pipeline 3.019 30 13.3/15.9/20.6 API 5L GR X 70 PSL 2 98 Yet to be commissioned N2 Preserved
Details of Terminals Under Rajkot base.
Sr. No. Pipeline Section Type of Station Terminals Remarks
1 Anand Rajkot Pipeline-B (ARPL-B) IPS+Metering IPS Bhirgupur
2 Anand Rajkot Pipeline-B (ARPL-B) SV+TOP Sudamada
3 Anand Rajkot Pipeline-B (ARPL-B) SV+DT Ratanpar DT of MRSPL
4 Anand Rajkot Pipeline-B (ARPL-B) SV+Metering Motimoldi
5 Anand Rajkot Pipeline-B (ARPL-B) SV+TOP Jyana
6 Anand Rajkot Pipeline-B (ARPL-B) RT+DT+Metering Rajkot RT of ARPL-B, DT of RJPL
7 Morbi Spurline (MRSPL) SV+Metering Navagam
8 Morbi Spurline (MRSPL) SV+Metering Jetparda
9 Morbi Spurline (MRSPL) Metering Terminal Dhuva
10 Morbi Spurline (MRSPL) RT+DT+Metering Morbi RT of MRSPL, DT of MMPL
11 Rajkot Jamnagar Pipeline (RJPL) SV+DT+Metering Bhodigodi DT of BAPL
12 Rajkot Jamnagar Pipeline (RJPL) SV Pipartoda
13 Rajkot Jamnagar Pipeline (RJPL) SV Berajapasaya
14 Rajkot Jamnagar Pipeline (RJPL) SV+Metering Chela
15 Rajkot Jamnagar Pipeline (RJPL) IPS+DT Pipli DT of GSFC Spurline
16 Rajkot Jamnagar Pipeline (RJPL) Metering Terminal Reliance
17 Rajkot Jamnagar Pipeline (RJPL) TOP Padana
18 Rajkot Jamnagar Pipeline (RJPL) Metering Terminal Motalakhiya
19 GSFC Spurline SV+Metering Saparpatiya
20 GSFC Spurline RT+Metering Sikka
21 Essar Spurline Customer End Nayara Refinery
22 Bhodgodi Ambardi Pipeline (BAPL) SV+TOP Devda
23 Bhodgodi Ambardi Pipeline (BAPL) RT+Metering Ambardi
Details of Terminals Under Anjar Sub Base
Sr. No. Pipeline Section Type of Station Terminals Remarks
1 MMPL (Morbi-Anjar) SV + Metering SV-1 Gala
2 MMPL (Morbi-Anjar) SV + TOP SV-2 Haripar
3 MMPL (Morbi-Anjar) SV + Metering SV-3 Navakatariya
4 MMPL (Morbi-Anjar) SV + Metering SV-4 Vondh
5 MMPL (Morbi-Anjar) SV + Metering SV-5 Bhimasar
6 MMPL (Morbi-Anjar) DT+ RT RT- Kharapashvariya
7 ABPL 18" (Kharapashwariya to Ratatalav) DT+ RT Ratatalav
8 ABPL 12" (Ratatalav to Nagor) SV + Metering Paddhar
9 ABPL 12" (Ratatalav to Nagor) RT + Metering Nagor
10 AMPL (Anjar-Mundra) SV + Tap off SV-1 Mathada
11 AMPL (Anjar-Mundra) Plot Gundala
12 AMPL (Anjar-Mundra) SV + Metering SV-2 Goyarsama
13 AMPL (Anjar-Mundra) DT + Metering RT-Mundra
14 Ajanta Spur Custmer End Ajanta
15 Sumangal Spur Metering Sumangal
16 Electrotherm spur Tap-off Electrotherm
17 Euro spur Metering Euro
18 Metrade spur Metering Metrade
19 Metrade spur Metering Indian Steel
20 Metrade spur Metering Ratnamani
21 Metrade spur TOP Resinance
22 Metrade spur TOP Plot 508
23 Chimique Spur Metering Chimique
24 Ramacylinder Conn. Metering Ramacylinder
25 Welspun spur SV + Metering Anjar CGS
26 Welspun spur Custmer End Welspun dispatch
27 Parle spur Metering Parle
28 Chromeni Spur Metering Chromeni
29 SNF Spur Metering SNF
Details of Terminals Under Bhavnagar Base
Sr. No. Pipeline Section Type of Station Terminals Remarks
1 Darod Jafrabad Pipeline DT Darod
2 SV+Metering Zinzer
3 SV+Metering+DT Vadhela DT of Botad Spurline
5 SV+Metering+DT Magalana DT of Bhavnagar Spurline
6 IPS+DT Tana DT of Tana Amreli Pipeline
7 SV Moti Babariyat
9 SV+Metering Ratol
11 RT+Metering GPPC
12 Botad Spurline TOP+Metering Barwala
13 RT Samadhiyala
14 Bhavnagar Spurline RT+Metering Vartej
15 Tana Amreli Pipeline TOP+Metering Malpara
17 SV+Metering Panchtobra
18 SV Sajantimba
19 RT+Metering Amreli
20 Pipavav Gundala Pipeline DT+Metering+RT Lothpur DT of Pipavav Gundala Pipeline & RT of Chhara LNG Connectivity Pipeline
21 Pipavav Gundala Pipeline TOP Sintex
22 SV Pati Mansa
23 RT+Metering+SV Gundala
24 Chhara LNG Connectivity Pipeline DT+Metering Chhara
26 SV Pati Mansa New
27 SWAN FSRU Connectivity Pipeline DT+Metering SWAN
GSPL TRANSMISSION LIMITED Natural Gas Grid
Annual Manitenance Schedule
Sr. No. Activity/ Description Frequency
1 Patrolling of Pipeline sections through GPS application (GSPL will provide the tablet/ mobiles with application)
1.1 Location Class 1 & Class 2 Q
1.2 Location Class 3 & 4 M
1.3 Location- High Consequence Area (HCA) M
1.4 Location-Critical HCA and ROW locations F
2.1 River Crossing Q
2.2 Rail/Road/Canal Crossing Q
2.3 Foreign Pipeline Crossing Q
2.4 Bubble leakage test of Station Piping Y
2.5 Checking of Casing Carrier System Q
3 Monitoring & Maintenance of CP System
3.1 Monitoring & Maintenance of TR Unit M
3.2 Calibration of Meters of TR Unit Y
3.3 PSP Monitoring Q
3.4 Instant pipe to Soil “OFF” potential Measurement at TLP of total pipeline section Y
3.5 Current Measurement in applicable TLP Y
3.6 Maintenance of Anode Ground Bed HY
3.7 Monitoring & Maintenance of Insulating Joint and Surge Diverter Q
3.8 Inspection of Interference Bonds Y
3.9 Checking of ER Probe/CTSU HY
3.10 Integrity Check of Zinc / Mg Anodes for applicable TLPs Y
3.11 Monitoring of HT line Crossing Q
4 Monitoring and Maintenance of Instruments
4.1 USM Meter run/Turbine meter checks of Redundant Skid (Y) Y
4.2 Calibration of Master Instruments (Temperature Bath, Beamax, Dead Weight Tester, multifuncation calibrator) Y
4.3 Calibration of Field Instruments (DPT/PT/TT/PG/TG/DPG, etc.) Y
4.4 Pressure Regulator and SSV checking H/AWR
5 Maintenance of Plant Equipments
5.1 Maintenance of Scraper Traps, Pig Handling equipments & QOC Y
5.2 Maintenance of Filters & QOC HY / AWR
5.3 Maintenance of D G Sets including all Ancilaries HY / AWR
5.4 Maintenance of Valves HY
5.5 Maintenance of Actuators HY
5.6 Overhauling & Calibration of Safety Valves & CRVs Y
5.7 Calibration of Safety Valves in actuator valve cylinder Y
5.8 Checking of Pig Signal Indicator Y
5.9 Third party inspection of 1 no. EOT Crane (5 Ton.) and 1 no. EOT Crane (15 Ton.) including Chain Pulleys at GSPL Gavridad terminal & Monorail 1.5 Ton at Gavridad, Navagam, Jetparda terminals with load testing (Testing Certificate shall be issued from Competent Person (Form-10)) under Rajkot Base. Y
5.10 Visual Inspection of pressure vessels at factory location by Competent Person HY
5.11 Checking of Above Ground Pipe thickness Y
5.12 Visual Inspection of Flange Gaskets, Nuts, Stud etc. and application of Molykote Grease etc HY/AWR
5.13 Calibration of Equipment & Accessories, Ultrasonic Thickness Gauge, Vernier Digital Caliper, Micrometer gauge, LEL Detector/O2/CO, Lux & dB Meters. (NABL Certified Laboratory only) Y
5.14 Measuring of vibration/pulsation & sound in Metering Skid Systems Y
6 Electrical Equipments
6.1 Maintenance of Electrical & Instrument Panels HY
6.2 Maintenance of Battery Bank HY
6.3 Visual inspection & General cleaning of Battery Banks including Eye Washer. M
6.4 Monitoring & Maintenance of Earth Pits (Conventional type as well as Chemical back fill compund type) HY
6.5 Cleaning of Cable Trench Y
6.6 Maintenance of AC Units Q/AWR
6.7 Maintenance of Area lighting system(Outdoor) and Indoor lighting and Fans. HY/AWR
6.8 Maintenance of Solar lighting system HY/AWR
6.9 Maintenance of Automatic Voltage Regulator HY /AWR
6.10 Checking and Sealing of Junction Box Y
6.11 Inspection & Maintenance of Flame Proof Lighting Fixture HY
6.12 Calibration of Multimer, Clamp Meter, Earth Tester, Insulation resistance tester, through NABL Certfied Laboratory OR Approved Authorised Service Agency. Y
6.13 Maintenance of Inverter and its Batteries Q
7 Fire & Safety
7.1 Checking & Calibration of F&Gas Detection System Q
7.2 Checking & Maintenance of Fire alarm & CO2 Flooding & Clean Agent System (FM200) Q
7.3 Checking & Maintenance of Fire Extinguishers Q
7.4 Monitoring of emissions environmental, ambient air & stack monitoring HY
7.5 Noise level monitoring and illumination measurement HY
7.6 Drinking water testing HY
8 General Activities
8.1 Health Checking of U/G installations including valves on sample basis (Every year one location per Base and one locations per Sub-base) Y
8.2 Peel-off test for checking Cathodic disbandment on sample basis AWR
8.3 Maintenance of RO & Water Cooler system Q/AWR
8.4 Pest control in Terminal Buildings (Office, Control Room,Electrical room, Battery Room, DG Room, CO2 Room, Store etc.), Process Area, Open Spaces etc to ristrict entry of rats, snake repellant treatment, lizard, crockroaches, Honey comb removal, Rodent bait station etc.) Q/AWR
8.5 Anti-termite Treatment in Terminal Buildings (Office, Control Room,Electrical room, Battery Room, DG Room, CO2 Room, Store etc.), Process Area, Open Spaces etc Y/AWR
8.6 Site survey and supervise GSPL pipeline crossings by any 3rd party operator, coordinate & liasioning for safe execution of crossing. AWR
8.7 Pipeline awarness program for villagers/ Public/Local /Authorities/Emergency Responders Q
8.8 Visit of Unmanned stations Q
8.9 LEL Checking of Ventline in Terminal/Station Y
9 Pipeline Integrity Management System
9.1 Population Density Index (PDI) Survey (max.100 Kms to be considered per year). AWR
9.2 Cleaning Pigging through HD foam pigs, 2/4 cup batch pig. (max. 100 Kms to be considered per years). AWR
9.3 DIG verification of pipeline sections AWR
9.4 Pneumetice testing of pressure vessels at factory act terminals (one location in Rajkot Base) AWR
9.5 CIPL Surevy 5Y/ AWR
9.6 DCVG/ CAT Survey AWR
F - FORT NIGHTLY
HY- HALF YEARLY,
AWR- AS & WHEN REQUIRED
AWA – AS & WHEN AVAILABLE
Schedule of Rate (SOR), Rev-00 "Appointment of Maintenance Contractor for Rajkot and Bhavnagar Bases of GTL Gas Grid" GTL Tender No: GTL/PROC/2026/10/O/510
Category of Registration in GST(Tick whichever is applicable)
Registered (Normal)
Registered (Composition Levy)
Type of Supply Under this Contract (Tick whichever is applicable)
Normal Supply of goods and services
Composite supply
1 The description given under the items of work in Schedule of Rates shall be deemed to include, wherever applicable, mobilisation ,labour, equipments, materials and fixing in position of all materials and equipments, disposal of wastages, desludging and allied operations at any stage of the work and all other labours and operations necessary whether specifically stated/implied or not, for the full and entire execution and completion of the relative works in all respects according to the contract. Cost of materials under the scope of Contractor’s supply & all other consumables/inputs required for carrying out the works & for permanent incorporation in the works for which rates are quoted in the "Schedule of Rates" shall be inclusive of all duties, taxes (excluding GST), etc. as applicable.
2 Base rates are provided, bidder to quote % (-) Discount or % (+) Accreation only. Bidder shall strictly quote as per price bid format (latest revision) only. Any bid not conforming to the price bid formats shall be liable for rejection.
3 Based on the SOR price, the contractor shall be liable to execute each SOR items at awarded rates as per the requirement given by GTL. In case contractor deny to execute any of the SOR item within the specified timeline given in the work request then the work shall be carried out by any other agency at the risk & cost of engaged ARC contractor. Cost of the same shall be recovered from the ARC contractor either from RA Bills or from Performanace Bank Garuentee (PBG).
4 Quantities mentioned in this SOR are estimated for evaluation purpose only. Payment shall be made at actual.
6 GTL reserves the right to reject any bid without any reason whatsoever.
Schedule of Rate (SOR), Rev-00 "Appointment of Maintenance Contractor for Rajkot and Bhavnagar Bases of GTL Gas Grid" GTL Tender No: GTL/PROC/2026/10/O/510
Sr No Sr No Description Goods/Services Estimated Quantity Per Year Unit of Measurement Estimated Unit Rate SOR Total Amount (Excl. GST)
SOR for Routine/AMP activities
2.30 1 Maintenance of Filter: Valve Operations, Opening of filters, cleaning of filter elements/re-placement of the filter elements and box-up. The job is including valve operation for filter isolation & Venting, nitrogen purging and the air-blowing of filter element with compressed air, drying them in open yard for 3 hours, reinstall them if required change with new elements as per instruction of GTL EIC. Activity Inclusive of the Nitrogen purging with max. 7 M3 by using certified N2 Pressure Regulator from Cylinder. The job inclusive of all consumables, equipment's, tools, Manpower, transportation of filter elements from designated store.(HY)
2.30.1 1.01 Size upto 8" QOEC Type 72 Nos. 9,000 211592 648,000
2.30.4 1.03 Size from 10" to 12" Flanged Door Type 4 Nos. 9,000 211595 36,000
2.30.7 1.04 Size from 14" to 18" QOEC Type 8 Nos. 10,000 80,000
1.06 Size 28" to 50" QOEC Type 8 Nos. 18,000 144,000
1.07 Size 52" to 70" QOEC Type 4 Nos. 35,000 140,000
2.31 2 Maintenance of Pig launcher/ receiver: Opening, cleaning and box-up of pig launcher / receiver of below sizes, including cleaning & replacement of "O" ring if required. Job includes supply & purging of N2.The job is including valve operation for Isolation & venting.(Y). O rings will be free issued by GTL. 0
3 Operation check of Manual/Gear/ Hydraulic operated Valves/ GOOV by manual & Pneumatic opening and closing in presence and as per instruction of GTL supervisor - as per size given up to 36" at various SV,RT,DT,IPS,Metering station (Including Consumables like Grease, Cotton Waste, etc.) No separate charges shall be paid for Manpower, Tools & Tackles, consumables used for this activities. Activity performed as per GTL work procedure & Report should be submitted in GTL approved format.(HY) 0
3.01 For SV Station with or with out TOP / Metering 86 Per station 10,000 213422 860,000
3.02 For TOP station/Customer end 18 Per station 5,000 213423 90,000
3.03 For IPS/DT/RT/ station 6 Per station 15,000 213424 90,000
3.04 For IPS/DV/RT/ with metering/ SV station 50 Per station 20000 1,000,000
2.52 4 Safety valve calibration of sizes as given below with men, materials tools & tackles, consumables. The job including dismantling of safety valve from the filter equipment/Pipeline/ Launcher/Receiver/Actuator Valve cylinders at height of maximum 3 meter, blinding of one upstream side of line flange of removed space of safety valve, Cleaning of all components, Lapping of nozzle ,change of body joint Gasket & disc if required, assembly of valve with repaired component, Calibration and Testing as found as left set pressure of safety valve at spot with all required materials tools & tackles. seat tightness required at 90% of test pressure & calibration of PG is required. Re-installation/erection of safety valve on equipment/Pipeline/ Launcher/Receiver/Actuator Valve cylinders in position after testing/calibration. Consumable such as nitrogen, grease, testing gaskets & painting of Valves etc shall be arranged at site by the contractor for the above job. Gasket for the pipes / joint flanges shall provided by GTL. Issuing a certificate of calibration by a competent person. All type of transportation is included in the job (Y) 0
2.52.1 4.01 For Actuator Valve (Size below1") 109 Nos. 2,569 211617 280,021
2.240 5 Visual Inspection & Certifications (Form:- 11) of filter/pressure vessels as per factory Act through approved competent person.(HY) 2 Per Visit 8,219 211662 16,438
CIV-115 6 Monitoring of RoU by foot patrolling including Rail/Road/Canal/River crossing with casing carrier system with the help of GPS based mobile application along the route of pipeline.(M/Q) 6600 kms 500 213425 3,300,000
CIV-118 7 Bubble leak test of all flanges and leakage point in Station piping. Report should be submitted in GTL approved format.(Y) 77 Per Station 2,500 213426 192,500
1 8 Checking of thickness for Station piping and submit the report in GTL approved format(Y) 77 Per Station 5,000 213427 385,000
3 9 Measurement of Vibration/Pulsation and noise monitoring of above ground piping system. Report should be submitted in GTL approved format.(HY) 27 Per Station 2,500 213428 67,500
5 10 Pipeline awareness program for Villagers/Public, Authority. Report should be submitted in GTL approved format.(Y).( programme which includes distribution of company signed letter with safety pamplets to Sarpach/Talati. The scope covers briefing of pipeline safety awareness among concern landowners, distribution of safety pamphlets, receving of letters to concern sarpach/talati, submission of time stamp photographs of programme with attendance record of participated concern landowners. The scope includes manpower, local transport, PPEs, communication is in scope of contractor. Contractor shall submit latest contact number of concern sarpanch & talati as per village list.) 410 Nos. 5,000 213429 2,050,000
7 11 Monitoring / Checking of Ch4 % at Common Vent line at various terminal. Report should be submitted in GTL approved format.(Y) 77 Nos. 300 213430 23,100
8 12 Above Ground pipe line Support checking. Report should be submitted in GTL approved format.(HY) 158 per Station 1,000 213431 158,000
20 13 Maintenance of RO system and Water cooler system. Job is inclusive of supply and replacement of all parts & consumable as per recommendation by OEM authorised person or /distributer or skilled person(Q) 28 Nos. 10000 213432 280,000
14 Monitoring and Maintenance of earthing system as per AMS (Annual Maintenance Schedule) by measuring earth pit resistance. The job includes cleaning of pit, checking and recording of earthing system circuit resistance by disconnecting Earth pit from the equipment's (provide alternative earthing if needed) and measure the earthing resistance of the disconnected pit by Winner's three pin method. The earth pit resistance value to be measured under two separate condition viz. (1) isolated from earthing grid and (2) when connected to earthing grid. After measurement it is re-connected and tightness of all connection to be confirmed. Anti corrosion gel /jelly shall be applied to all earthing connections checked, if required. Supply & replacement of nut bolts, if required. The work includes adding salt water& coal slurry, if required to the earth pits if required and replacement of nut bolts. The job shall be carried out and submission of reports on (HY) basis under a supervision of electrical supervisor. 2260 Per Pit 500 205707 1,130,000
15 Servicing of Air-Conditioners (includes cleaning of blower condenser fan, cleaning of air filter with vacuum cleaner, Evaporator coil, condenser coil and equipment, metallic/plastic body parts with soaked cotton cloths, Condenser ,Oil the motor as and when required, Checking of Voltage stabilizers / Timers and remote control units to maintain these in healthy conditions, Cleaning of Outdoor unit by Blower, Checking of working of compressor (Ampere of Compressor),Pressure checking of refrigerant, Checking the working of Stabilizer unit, one of the Quarter shall have wet jet cleaning of both indoor & outdoor units. Checking of working of Capacitors of outdoor unit, Checking of drain pipe of outdoor unit, Checking the working of Flapper motor)(Q). 1386 Nos. 1,200 209166 1,663,200
16 Servicing of DG Sets as per rating mentioned below ( includes physical inspection, checking for damaged parts, repairing of damaged parts, oil checking, trial run, synchronize checking, full load RPM checking, Voltage checking and adjustment, Lube oil Checking, battery checking etc. with men, tools and tackles as required). Cost of spare parts replaced shall be paid as per relevant SOR. No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity.(HY) 0
17 Servicing of below mentioned electrical panel: The job shall include cleaning of the panel from outside and inside by vacuum cleaner & Manual, checking of operation of MCCB/ACB/MCB, Indication Lamp, Meters (KWh/Voltmeters/Ammeters/PF meters/Frequncy Meters etc.), Contactor, Fuses, CTs, Spacers etc. and sealing of the open cable entries by PVC/GI blind plug . The job shall also include Identification, termination & proper Dressing of Cable. All required tools, tackles, manpower and PVC/GI blind plug shall be in contractor's scope. The job shall be carried out by qualified electrician.(HY) 0
17.02 Other Panel except MEDB 472 Nos. 3,000 210925 1,416,000
18 Maintenance of cable trench and cable trays which involves cleaning by Vaccum Cleaner & manual, cable dressing, cable identification etc.No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity.(Y) 1230 R. Mtr. 100 209261 123,000
19 Ni-CD Battery Bank maintenance including cleaning of battery by removing each cells from battery racks, dust/ corrosion removal from terminals & battery cells, Specific Gravity Checking, checking of cell voltage, Water level checking & refilling of DM water (if required), application of petroleum jelly on each battery terminal & links as per instruction of Engineer In charge. All required tools tackles like hydrometer, Multimeter, insulated spanners, etc., PPEs, DM water & other consumable are in the scope of contractor . Contractor shall submit report in the prescribed format. No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity.(HY) 40534 Per battery 40 209271 1,621,360
20 PSP field measurement & inspection / maint. of TLP. Execution of PSP monitoring by field measurement of parameters / reading from TLP’s, and submission of pipeline Section wise report(s) along with copy of hand written field report as per GTL’s prescribed format / procedures including checking and cleaning / maintenance of TLP's as specified in the scope of work and procedure. The scope also includes the reading collection / measurement of parameters of Casing soil Potential, AC potential, Foreign Pipeline Potential, Monitoring of Insulating Joints including Surge Diverter etc. [The average distance between two TLP is 1.00 km approx.](Q) 0
20.01 24" x 101.420 kk ARPL-Section B (Total no of TLP 123 NOS) 4 LS 49,200 196,800
20.02 18"x 67.802 kmMorbi SPUR LINE (Total no of TLP 88 NOS) 4 LS 35,200 140,800
20.03 30" x 109.172 km Rajkot Jamnagar Pipeline (Total no of TLP 132 NOS) 4 LS 52,800 211,200
20.04 24" x 5.779 km EOL Spur Pipe Line (Total no of TLP 11 NOS) 4 LS 4,400 17,600
20.05 12" x 46.984 Bhodighodi Ambardi Pipeline (Total no of TLP 55 NOS) 4 LS 22,000 88,000
20.06 8" x 16.902 kmGSFC sikka Spur Pipeline (Total no of TLP 44 NOS) 4 LS 17,600 70,400
20.07 18"X 128.938 KM Morbi-Mundra Pipeline (Total no of TLP 157 NOS) 4 LS 62,800 251,200
20.08 12" X 6.65 KM Ajanta Spur (Total no of TLP 10 NOS) 4 LS 4,000 16,000
20.09 8" 4.4 KM Sumangal Glass Spur (Total no of TLP 9 NOS) 4 LS 3,600 14,400
20.10 8"X 10 KM Electrothem Spur (Total no of TLP 12 NOS) 4 LS 4,800 19,200
20.11 8"X 4.3 KM Euro Spur (Total no of TLP 6 NOS) 4 LS 2,400 9,600
20.12 12" X 9 KM Metrade Spur (Total no of TLP 20 NOS) 4 LS 8,000 32,000
20.13 8" X 1.62 KM Chimique Spur (Total no of TLP 5 NOS) 4 LS 2,000 8,000
20.14 6"X 2.957 KM SNF Spurline (Total no of TLP 8 NOS) 4 LS 3,200 12,800
20.15 12" X 5 KM Welspun Spurline (Total no of TLP 9 NOS) 4 LS 3,600 14,400
20.16 18" X 7.4 KMAnjar-Bhuj Pipeline (ABPL-18") (Total no of TLP 12 NOS) 4 LS 4,800 19,200
20.17 12" X 35.2 KM Anjar-Bhuj Pipeline (ABPL-12") (Total no of TLP 45 NOS) 4 LS 18,000 72,000
20.18 6" X 5.44 Paddhar Parle Connectivity (Total no of TLP 9 NOS) 4 LS 3,600 14,400
20.19 36 " X 67.4 KM Anjar-Mundra Pipeline (AMPL) (Total no of TLP 107 NOS) 4 LS 42,800 171,200
20.20 8" X 1.2 KM Chromeni Spur (Total no of TLP 1 NOS) 4 Nos. 400 1,600
20.21 24"x 101.77 km Darod - Jafrabad-A (Total no of TLP 120 NOS) 4 LS 48,000 192,000
20.22 24"x 110.323 km Darod - Jafrabad-B (Total no of TLP 120 NOS) 4 LS 48,000 192,000
20.23 8"x 23.4 km Botad Spurline (Total no of TLP 29 NOS) 4 LS 11,600 46,400
20.24 12" x 14.377 km Bhavnagar Spurline (Total no of TLP 18 NOS) 4 LS 7,200 28,800
20.25 12" x 75.2 kmTana Amreli Pipeline (Total no of TLP 82 NOS) 4 LS 32,800 131,200
20.26 12"x 45.531 Pipavav Gundala Pipeline (Total no of TLP 57 NOS) 4 LS 22,800 91,200
20.27 36" x 88.722 km Chhara LNG Connectivity Pipeline (Total no of TLP 125 NOS) 4 Nos. 50,000 200,000
20.28 30"x 3.019 km SWAN FSRU Connectivity Pipeline (Total no of TLP 8 NOS) 4 LS 3,200 12,800
20.29 Digital Multimeter 15 Each 2,000 213434 30,000
20.30 Clamp meter 9 Each 2,000 213435 18,000
20.32 Earth Tester-ET 1 Each 2,000 213437 2,000
20.33 Lux meter 3 Each 2,000 6,000
20.34 Infrared Thermometer 3 Each 2,000 6,000
20.35 Db Meter(Sound Meter) 2 Each 2,000 4,000
21 Visual Inspection & General Cleaning of Battery Bank (M) 732 Per station 1,500 213438 1,098,000
22 TR Unit Monitoring & Maintenance (M) 372 Per Tr Unit 1,600 211428 595,200
23 TR unit meter and transducers calibration (Y) Minimum 5 panel meter and 03 transducers 31 Per TR Unit 5,000 210643 155,000
24 Anode Ground Bed Monitoring & Maintenance (HY) 62 per location 1,000 211429 62,000
25 ER Probe/CTSU/Corrosion coupon monitoring (HY) 79 Per location 1,000 211430 79,000
26 Checking & sealing of all junction boxes including FLP JBs & Inspection of Flame Proof Lighting Fixture(HY) 158 Per station 2,000 213441 316,000
27 ON-OFF Potential Survey: Yearly execution of ON-OFF Potential Survey(Y) 0
27.01 24" x 101.420 kk ARPL-Section B (Total no of TLP 123 NOS) 1 LS 61,500 61,500
27.02 18"x 67.802 kmMorbi SPUR LINE (Total no of TLP 88 NOS) 1 LS 44,000 44,000
27.03 30" x 109.172 km Rajkot Jamnagar Pipeline (Total no of TLP 132 NOS) 1 LS 66,000 66,000
27.04 24" x 5.779 km EOL Spur Pipe Line (Total no of TLP 11 NOS) 1 LS 5,500 5,500
27.05 12" x 46.984 Bhodighodi Ambardi Pipeline (Total no of TLP 55 NOS) 1 LS 27,500 27,500
27.06 8" x 16.902 kmGSFC sikka Spur Pipeline (Total no of TLP 44 NOS) 1 LS 22,000 22,000
27.07 18"X 128.938 KM Morbi-Mundra Pipeline (Total no of TLP 157 NOS) 1 LS 78,500 78,500
27.08 12" X 6.65 KM Ajanta Spur (Total no of TLP 10 NOS) 1 LS 5,000 5,000
27.09 8" 4.4 KM Sumangal Glass Spur (Total no of TLP 9 NOS) 1 LS 4,500 4,500
27.10 8"X 10 KM Electrothem Spur (Total no of TLP 12 NOS) 1 LS 6,000 6,000
27.11 8"X 4.3 KM Euro Spur (Total no of TLP 6 NOS) 1 LS 3,000 3,000
27.12 12" X 9 KM Metrade Spur (Total no of TLP 20 NOS) 1 LS 10,000 10,000
27.13 8" X 1.62 KM Chimique Spur (Total no of TLP 5 NOS) 1 LS 2,500 2,500
27.14 6"X 2.957 KM SNF Spurline (Total no of TLP 8 NOS) 1 LS 4,000 4,000
27.15 12" X 5 KM Welspun Spurline (Total no of TLP 9 NOS) 1 LS 4,500 4,500
27.16 18" X 7.4 KMAnjar-Bhuj Pipeline (ABPL-18") (Total no of TLP 12 NOS) 1 LS 6,000 6,000
27.17 12" X 35.2 KM Anjar-Bhuj Pipeline (ABPL-12") (Total no of TLP 45 NOS) 1 LS 22,500 22,500
27.18 6" X 5.44 Paddhar Parle Connectivity (Total no of TLP 9 NOS) 1 LS 4,500 4,500
27.19 36 " X 67.4 KM Anjar-Mundra Pipeline (AMPL) (Total no of TLP 107 NOS) 1 LS 53,500 53,500
27.20 8" X 1.2 KM Chromeni Spur (Total no of TLP 1 NOS) 1 LS 500 500
27.21 24"x 101.77 km Darod - Jafrabad-A (Total no of TLP 120 NOS) 1 LS 60,000 60,000
27.22 24"x 110.323 km Darod - Jafrabad-B (Total no of TLP 120 NOS) 1 LS 60,000 60,000
27.23 8"x 23.4 km Botad Spurline (Total no of TLP 29 NOS) 1 LS 14,500 14,500
27.24 12" x 14.377 km Bhavnagar Spurline (Total no of TLP 18 NOS) 1 LS 9,000 9,000
27.25 12" x 75.2 kmTana Amreli Pipeline (Total no of TLP 82 NOS) 1 LS 41,000 41,000
27.26 12"x 45.531 Pipavav Gundala Pipeline (Total no of TLP 57 NOS) 1 LS 28,500 28,500
27.27 36" x 88.722 km Chhara LNG Connectivity Pipeline (Total no of TLP 125 NOS) 1 62,500 62,500
27.28 30"x 3.019 km SWAN FSRU Connectivity Pipeline (Total no of TLP 8 NOS) 1 LS 4,000 4,000
28 Current Measurement in B type TLP(Y) 180 Per TLP 500 213439 90,000
29 Integrity check of Zn/Mg anode(Y) 225 Per Location 50 213440 11,250
30 Calibration of secondary instruments such as Pressure Transmitter, Diff Pressure Transmitter, Temperature Transmitter, Pressure Gauge, Diff Pressure Gauge, Temperature Gauge, RTD at respective locations. (Trained manpower as well as master calibrator traceability with NABL certified lab and the calibrator shall have equal or better accuracy than the field instrument, in the scope of contractor).(Y) 0
30.04 TG of Range (0-100 degree C) 27 Nos. 737 206359 19,899
31 Removal and Re-installation of Turbine Meter of size mentioned below, Profiler Plate, Spool Piece Between Profiler Plate to Meter , Upstream Spool Piece of Profiler, Spool Piece between Meter and Metering Temperature Measurement. No separate charges shall be paid for manpower, consumables, lifting equipment's, valve operations, tools & tackles used during execution of this activity. Gasket shall be supplied by GTL at designated store.(Y) 0
32 Removal and Re-installation of Ultrasonic Meter of size mentioned below, Profiler Plate, Spool Piece Between Profiler Plate to Meter, Upstream Spool Piece of Profiler, Spool Piece between Meter and Metering Temperature Measurement. No separate charges shall be paid for manpower, consumables, lifting equipment's, valve operations, tools & tackles used during execution of this activity. Gasket shall be supplied by GTL at designated store.(Y) 0
33 Maintenance of Pressure/Flow control valve.(Y) 12 Nos. 2,500 213454 30,000
34 Checking of Pig Signal Indicator.(Y) 38 Per Sation 500 213455 19,000
34.01 Calibration of Master Instruments(Multifunctional calibrator)(Y) 4 Nos. 45,000 213456 180,000
34.02 Calibration of Master Instruments (Temperature bath, Make: ametek type:RTC-156 BM RTD sensor)(Y) 1 Nos. 30,000 213457 30,000
34.03 Calibration of Master Instruments(Dead Weight tester, Model 580)(3Y) 4 Nos. 60,000 213458 240,000
35 Checking and maintenance of Local control panel(LCP)(HY) 116 Nos. 1,500 213460 174,000
36 Checking and maintenance of CO2/FM200 flooding system(Q) 232 No 3,000 213461 696,000
37 Illumination Monitoring at various GTL terminals at Night including required calibrated instrument and transportation up to the respective sites as per instruction of EIC. Report shall be submitted in GTL approved format(HY) 120 per Station 5,000 210785 600,000
38 Environmental Monitoring by carrying out the Ambient air quality measurement for Particulate Matter (P.M10 & PM 2.5), Oxides of Sulphur (Sox) and Oxides of Nitrogen (NOx) and Noise level measurement at least 7 different spot ( i.e. 7samples) as per GTL format/EIC Instruction & GPCB norms in each SV station for 24 hrs and analysis of the result for submitting to GPCB as per scope of work and instruction by Engineer-in-charge. The scope includes noise level recording for HVS machines also. Noise level monitoring includes DG area during day & night time.(HY) 120 Per Station 8,500 206011 1,020,000
39 D.G Sets Stack monitoring as per GPCB norms from 51 KVA to 125 KVA(HY) 20 Nos. 4,409 210009 88,180
40 Portable drinking water analysis as per BIS-10500 (2012)(HY) 14 Per Sample 3,000 213462 42,000
41 Checking and maintenance of Fire Extinguishers(Q) 0
42 Inspection and updation of first aid boxes & PPEs (Items is charged as per separate SOR). Report should be submitted in GTL approved format.(Q) 280 Per station 500 213466 140,000
43 Calibration of Portable gas detectors(Y) 0
44 Condition Checking of underground sectionalizing Valves/Tap-off including it's by-pass valves and associated underground piping. The job includes a) Removal of gravels, Excavation( (Removal of gravel from Process Area, Manual Excavation) and making trench of appropriate size, required for checking of valves and under ground piping. Excavation to be carried out segragating sand, gravel, mud, PVC so that backfilling can be done appropriately. Thickness measurement of valve body as well as underground piping, b) Reconditioning of coating using R-95 Epoxy or equivalent coating to be claimed as per relevant SOR (Supply & Application with minimum thickness of 700 microns). c) Holiday test for the valve body with 3 kv and underground piping minimum 12 KV d) Backfilling & restoration as found condition, e) This include removal and re-installation of PT/TT/PGD/FPL stand/pole, if required. f) The supply of all consumables, utilities, equipment, and all manpower required, valve cleaning and surface preparation, repairing of coating defects (resulting in holiday in coating) and testing including all handling, transportation, etc. included in this schedule of item. This includes Supply & replacement of Polythelene sheet (sheet 0.5 mm thk) during the course of valve checking. 0
45 Pneumatic testing of Launcher/Receiver, Filters as per GTL Requirements Test Pressure shall be 1.1 times of design pressure (MAOP), holding period- Min 30 minutes. Test includes Complete Pneumatic test arrangement i.e. test facilities with high pressure hose pipe, Calibrated digital pressure gauge, suitable manifold and any special requirement to conduct the Pneumatic test at site location and submission of reports. Required Valve operation, blinding if required, removal of filter elements, re-installation of filter elements after completion of Pneumatic Test. No separate charges shall be paid for manpower, consumables, lifting equipments, Nitrogen Gas, tools & tackles used during execution of this activity. Positive isolation of connected piping system to the equipments to be tested, if required. 0
45.01 Launcher/ Receiver barrel size from 20" to - 36" dia 2 Nos. 150,000.00 300,000
45.02 14" to 20" dia size Filter 2 Nos. 50,000.00 100,000
46 Load testing of EOT/Mono Rails of various capacities in presence of competent authority including supply of dead weight block of required capacity and submission of certificates. The job includes examination and testing of lifting tools and tackles as per Factories Act,1948 and providing certificate in FORM No:10 (Prescribed under rule 60) by competent person who has certificate possessing by issued Factory Inspector . Tested date, safe working load, due date etc shall be written on the equipment at end of testing as per instruction of Engineer In-Charge. No separate charges shall be paid for manpower, consumables,lifting equipments, transportation of test load, tools & tackles used during execution of this activity. 0
46.01 up to 2 Tonne 4 Nos. 10000 40,000
47 Maintenance of Solar Lights. 254 Nos. 1200 304,800
48 Monitoring and Maintenance of Copper/GI Chemical earthing system as and when required.The job includescleaning of pit, filling of chemical backfill materail as reasistance value is above acceptable limit. After maintenance measurement of grid & pit resistance to be done. After measurement it is re-connected and tightness of all connection to be confirmed. Anti corrosion gel /jelly shall be appliedto all earthing connections . Supply & replacement of SS nut bolts with double washer, if required. The work includes The job shall be carried out by a qualified electrical engineer and endorsed by a competent authority of respective region and submission of reports.condition viz. 19 Per Pit 800 15,200
49 Maintenance of Automatic servo control Voltage regulator of rating mentioned below for General Servicing & checking of Input, Output, Set Voltage and Load current including following activities & as per GTL approved SoP format:- 1) Checking of Smooth operation of Variac by using Increase/decrease operation by keeping in manual mode operation. 2) Operational check for under and Over voltage relay for individual phase- R-Y-B. 3) Operational check for load tripping during failure of any phase if any. 4) Opearational check of load on bypass. 5) Checking of Door status/lock status/ cleanliness of panel enclousure. 6) Checking of Transformer- Insulation burnt/abnormal sound, temperature measurement with IR Gun, Neutral to earth potential in (V). 6) Checking of Cable/cable lug connection, Dimmer arm coupling with servo motor, Gear screw coupling dimmer arm & servo motor, carbon brush contact on variac, earth cable continuity, Lamp test for LED. No separate charges shall be paid for manpower, consumables, tools & tackles used during execution of this activity. 0
50 Surface preparation of new piping/spool/Fittings, Steel Structural surfaces with Bristle Blaster machine, or blasting methods. Finish of surface quality SA 2 ½ and roughness 60 microns minimum by providing shot/sand of approved quality, shot/sand blasting equipment's & its accessories, manpower, material etc. The job also includes painting of piping spool including supply of paint and application of 1 coats of Neromastic 400(Mixture of Part-A & Part-B) or equivalent high build epoxy primer of 150 micron and 1 coats of Nerothane Enamel (PU)(Mixture of Part-A & Part-B) or equivalent Poly eurathene paint of golden/ cannery yellow/ any applicable colour of 150 micron or as instructed by GTL with of approved quality including stencilling of line numbers, pipe tagging, flow direction arrow, other lettering as found condition of pipeline as per instruction of GTL EIC. This includes covering of nut-bolts using masking tape and marking of thickness measuring spots during surface preparation & painting works 300 Sq. Mtr. 500 213473 150,000
51 Surface preparation of Installed (operational) piping/spool/Fittings, Steel Structural surfaces with manually scraping methods including manpower and material etc. The job also includes painting of piping spool including supply of paint and application of 1 coats of Neromastic 400(Mixture of Part-A & Part-B) or equivalent high build epoxy primer of 150 micron and 1 coats of Nerothane Enamel (PU)(Mixture of Part-A & Part-B) or equivalent Poly eurathene paint of golden/ cannery yellow/ any applicable colour of 150 micron or as instructed by GTL with of approved quality including stencilling of line numbers, pipe tagging, flow direction arrow, other lettering as found condition of pipeline as per instruction of GTL EIC. This includes covering of nut-bolts using masking tape and marking of thickness measuring spots during surface preparation & painting works 3150 Sq. Mtr. 500 213474 1,575,000
52 Repair of Pipeline / Flange / RTD Thermowell/IJ/Valves Body at leakage portion or less thickness locations by supply and application of leak clamp which can be installed on line and injecting sealing material. The job includes cleaning of pipeline / flange / RTD Thermowell/IJ/Valves, installation of leak clamp or any other leak clamp which can be installed on line and injecting sealing material on pipes. The job includes the flange / RTD Thermowell/IJ/Valves and restore the field to its original conditions. The job includes man-power, transportation and other resources. This job shall be carried out by certified OEM / vendor only. 0
53 Peel-off test on existing buried pipeline to check the health of pipeline and corrosion on pipe surface. Job includes excavation, Dewatering& backfilling of required size. After inspection, cleaning, coating repair, holiday check, back filling and final clean-up. etc, as per drawing and direction of E.I.C. Survey is to be carried out on pipelines of dia. 6”, 8’’, 10", 12’’, 16", 18’’, 24’’, 30”,36" including man power, transportation, machinery, peel-off test equipment, temperature gun, etc. 10 Per Pit 19,320 213153 193,200
54 Installation of above ground valves(Ball/Glove/ Check) of various sizes in piping system including handling, blind removal providing temporary supports if necessary, Studs bolt loosening / tightening, gasket insertion and torque setting by torque wrench with all tools/tackles/manpower etc. of valves sizes, Hydra and other lifting equipment inclusive of scaffolding arrangement at site if required including valve operation. Gasket shall be provided by GTL. 0
54.01 Up to & including 1” NB 15 Nos. 446 208652 6,690
55 Dismantling of valves(Ball/Globe/Check) from the line and putting blinds / spool pieces etc., for various pipe sizes etc. including Stud bolt loosening, gasket changing, handling with all tools / tackles / manpower etc. of valves sizes. Gasket shall be provided by GTL. 0
55.01 Up to & including 1” NB 15 Nos. 446 207121 6,690
56 Dismantling or Installation of Blind Flanges from A/G piping for various pipe sizes including nut bolt removing & handling with all tools / tackles / manpower/machinery & consumables etc. and stacking all within radius of 250 Mts as per GTL EIC instructions. 0
57 Gas cutting, grinding, and bevelling of various diameter station pipes of Sch-80 (Sch-160 up to 2" pipe). The job inclusive of all manpower, transportation, consumables, equipment's, tools, NDT check of bevel end etc. 0
58 Dismantling of piping spool along with flanges from line for various pipe sizes and putting blind including nut bolt removing & handling with all tools / tackles / manpower/machinery etc and stacking all within radius of 250Mts as per GTL EIC instructions.(No separate charges shall be paid extra for manpower & equipment's used) 0
59 Installation of piping spool along with flanges for various pipe sizes including blind removal, nut bolt removing ,stud cleaning, tightening and torque setting by torque wrench & handling with all tools / tackles / manpower/ machinery within radius of 250 Mts etc as per GTL EIC instructions.(No separate charges shall be paid extra for manpower & equipment's used) 0
60 Supply and Installation of chequered plate of 6 mm thickness for trenches, platforms etc including application of red oxide primer and two coats of finish paint of approved quality.(No separate charges shall be paid for gas cutting, grinding & welding of edges of chequered plate & transportation of the same) The job inclusive of all consumables, equipment's, tools, labour etc. removal of existing installed chequered plate from Operating plat form, Pit, Etc 30 Sq. mtr 5,144 208899 154,320
61 Providing and fixing pre coated galvanized G.I. Sheet(0.6 mm thick trapezoidal/Corrugated profile) of approved colour on roofing and sides of Metering system or DG Sets as per manufacturer’s instructions including providing sealant in the overlapping portion of sheets complete and including all accessories. 30 Sq. mtr 1,086 208901 32,580
62 Providing & fixing hand railing with Class-B pipes on equipment's like filter, PRS, operating platforms, buildings etc. The job includes surface cleaning, supply and application of two coats of red oxide primer and two coats of finish paint of approved quality. The job also includes removal of existing damage railing wherever is required including cutting ,grinding etc. The job is to be executed as per the direction of the E.I.C. 50 Mtr. 782 210102 39,100
63 Replacement by removing old gaskets including tightening and loosing of Flanges ,stud cleaning, tightening and torque setting by torque wrench with all tools / tackles / manpower/ machinery etc as per GTL EIC instructions. Gasket shall be provided by GTL at designated store. 0
64 Fabrication and installation of Above ground piping of grade ASTM A333 Gr.6 / API 5L/X65 & equivalent grade of different schedule including, handling, aligning, cutting, bevelling /edge preparation, installation of associated fittings / flanges, fit-up, tie-in, welding, Radiography, UT, DP, transportation of fabricated spool to location, temporary supporting, erection of different size of fabricated aboveground piping at all elevations including handling, temporary supporting etc. The job includes carrying out hydrostatic testing as per GTL approved procedure of completed Piping loop / Piping system as approved by Owner / Owner’s Representative to the specified pressures, providing all testing equipment's / instruments / accessories, blind etc. including Pressure recorder, Temperature probe, Temperature recorder. Dewatering, surface preparation & painting of Spool after successful completion of hydro testing is also including in scope. (Pipe/ pipefittings shall be issued by GTL at designated store.) 0
64.01 Pipe Wall thickness ranging from 6.4 mm– 8.56 mm 3 Inch. Dia. 1,500 210104 4,500
64.02 Pipe Wall thickness ranging from 8.57 mm– 17.4 mm 3 Inch. Dia. 1,768 210105 5,304
64.03 Pipe Wall thickness ranging from 17.5 mm– 32 mm 3 Inch. Dia. 1,983 210106 5,949
64.04 PQR laboratory charges for 2” WPS 1 Nos. 15,336 15,336
64.05 PQR laboratory charges for 4” WPS 1 Nos. 15,336 15,336
64.06 PQR laboratory charges for 8” WPS 1 Nos. 15,336 15,336
64.07 PQR laboratory charges for 12” WPS 1 Nos. 15,336 15,336
64.08 PQR laboratory charges for 18” WPS 1 Nos. 15,336 15,336
64.09 EQT for 24 MM MS plate (SMAW) 1 Nos. 15,336 15,336
64.10 EQT for 24 MM MS plate (GTAW) 1 Nos. 15,336 15,336
64.11 EQT for 16 MM MS plate (SMAW) 1 Nos. 15,336 15,336
64.12 EQT for 16 MM MS plate (GTAW) 1 Nos. 15,336 15,336
64.13 NDT charges for 2” WPS 1 Nos. 1,071 1,071
64.14 NDT charges for 4” WPS 1 Nos. 1,689 1,689
64.15 NDT charges for 8” WPS 1 Nos. 3,320 3,320
64.16 NDT charges for 12” WPS 1 Nos. 4,601 4,601
64.17 NDT charges for 18” WPS 1 Nos. 6,524 6,524
64.18 NDT charges for EQT (24 MM plate) 1 Nos. 2,737 2,737
64.19 NDT charges for EQT (16 MM plate 1 Nos. 2,737 2,737
65 Re-conditioning of coating of underground gas pipeline after locating the pipeline as per the coating fault. The activity includes (a) Excavation to expose the line to suitable depth to expose the pipeline and provide working space around the pipeline.(b)Removal of existing coating by using scrappers etc. and cleaning the surface to fine finishes by power brush / suitable method.(c) Rectification of Coating of the defects by HEAT SHRINKABLE /DENSO MAKE after surface preparation by mechanical cleaning, primer application, wrapping of tape, edge preparation, holiday test etc.(d)Back filling the trenches and restoring the fields to the satisfaction of GTL. Cleaning ROU of any debris etc.(e) The supply of all consumables, utilities, dewatering Pump equipment, and all manpower required, pipe cleaning and surface preparation, repairing of coating defects (resulting in holiday in coating) and testing including all handling, transportation, etc. included in this schedule of item.(f)any crop compensation to the land owner / farmers shall be in the scope of GTL. (No separate charges shall be paid for manpower, consumables, equipment's, tools used for this activity) 0
65.01 DENSO / RayChem MAKE TAPE (Tap width 150 mm with inner layer with 50 % of overlap & outer layer with 50 % of overlap) 60 Sq. Mtr. 8,040 213177 482,400
65.02 HEAT SHRINKABLE Sleeve upto 8" dia 1 Nos. 8,122 208934 8,122
65.03 HEAT SHRINKABLE Sleeve from 10" to 18" dia 1 Nos. 8,122 8,122
65.04 HEAT SHRINKABLE Sleeve from 24" to 36" dia 1 Nos. 8,455 8,455
65.05 COATING REPAIR PERP HTLP 80 3 Sq. Mtr. 7,678 213179 23,034
65.06 COATING REPAIR FILLING MATERIAL MASTIC 3 Sq. Mtr. 7,900 213180 23,700
65.07 R-95 EPOXY (MINIMUM 700 Micron & holiday test with 3 KV 30 Sq. Mtr. 8,122 243,660
66 Checking of above ground pipeline supports by lifting the pipe section, providing temporary supports by standard Engineering practises and rectification measures like application of paint to be carried out and fibre sheet of proper dimension shall be placed. Any rectification in support shall be paid as per the relevant SOR. (Measurement shall be done on the basis of Dia of Pipeline and Nos. of Support to be checked) No separate charges shall be paid for Manpower, Tools & Tackles, consumables used for this activities. 0
67 Painting of Valves (Ball, Globe & Check) of different sizes with two coats of finished paint of epoxy paint of suitable colour of approved make as per the GTL Vendor list attached with this tender to give an even shade after proper scraping of existing paint by power brushing or suitable method and clearing of surface free from foreign materials as per the instructions of GTL EIC. The job is inclusive letter writing of tag Number as per direction of EIC 0
68 Painting of Actuators (excluding SS and Panel Part) installed on different sizes of valves with two coats of finished paint of epoxy paint of suitable colour of approved make as per the GTL Vendor list attached with this tender to give an even shade after proper scraping of existing paint by power brushing or suitable method and clearing of surface free from foreign materials as per the instructions of GTL EIC. 0
69 Supply and Installation of "U" Clamps of CS material of standard type with NPT at bolting end including polyethylene insulation/conduit for "U" Clamps including nuts and washers for different size of pipe clamps as per instruction of EIC. No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity. This include removal of old rusted U Clamps. 0
70 Hydro testing of, Filters as per GTL Requirements( Test Pressure- 150 Barg, Holding period - Min 4 Hours). Test includes Complete hydrostatic test arrangement i.e. test facilities with high pressure hose pipe, Calibrated digital pressure gauge, pressure recorder & chart, suitable manifold and any special requirement to conduct the hydrostatic test at site location and submission of reports. Required Valve operation, blinding if required, removal of filter elements, re-installation of filter elements after completion of Hydro- test. No separate charges shall be paid for manpower, consumables, lifting equipments,water, tools & tackles used during execution of this activity. The job includes examination and testing of pressure vessel as per Factories Act 1948 and providing certificate in FORM No:11 (Prescribed under rule 61) by competent person who has certificate possessing by issued Factory Inspector. Tested date, Test Pressure, due date etc shall be written on the equipment at end of testing as per instruction of Engineer In-Charge. 0
70.01 upto 12" dia size Filter 1 Nos. 11,816 213121 11,816
70.02 14" to 20" dia size Filter 1 Nos. 18,494 213122 18,494
70.03 24" to 30" dia size Filter 1 Nos. 20,035 213123 20,035
70.04 36" to 60" dia size Filter 1 Nos. 28,254 213124 28,254
71 Hiring of following equipment's for doing any emergency work with all required valid test certificates. The period of hiring will start after the equipment reaches at site and ends when equipment leaves the site. Break down period of equipment will not be paid. Normal working time per day will be 8 Hrs. Rate for idle time shall be 50%. Night is not included in idle time except if works will continue in night. Hiring rates is inclusive of diesel, operators, maintenance cost, loading/unloading of equipment's by Hydra/manual at site. 0
71.01 Dewatering pump of capacity 20KL with required capacity D.G.Set 36 Per Hour 699 207136 25,164
71.02 Air Compressor of capacity 75 CFM with required capacity D.G.Set 1 Per Hrs. 585 207162 585
71.03 Hydra of lifting capacity 10MT to 15 MT along with required wire ropes & D-Shackle 72 Per Hrs. 1,541 102223 110,952
71.04 Tractor Mounted Pneumatic Type Rock Breaker 1 Per Hrs. 1,078 102228 1,078
71.05 Crane of capacity up to 50MT along with required wire ropes & D-Shackle 8 Per Hrs. 3,500 28,000
71.06 15KVA DG set: 8 Per Hour 700 5,600
71.07 25KVA DG set: 1 Per Hour 800 800
72 Schedule of rates for extra works for manpower supply (Total 26 day per month is counted in per month SOR) 0
72.01 Qualified Welder 11 Per 8 Hr. 6,500 208224 71,500
72.02 Fitter/Grinder 21 Per 8 Hr. 2,500 208225 52,500
72.03 Electrician/ Wireman 21 Per 8 Hr. 2,000 208223 42,000
72.05 Helper/Unskilled Labour 41 Per 8 Hr. 1,200 208220 49,200
72.08 Carpenter 3 Per 8 Hr. 2,000 208580 6,000
72.09 Autocad Draftsman 3 Per 8 Hr. 5,000 213475 15,000
72.10 Mechanical technician 3 Per 8 Hr. 2,000 213476 6,000
72.11 Instrument technician 3 Per 8 Hr. 2,000 213477 6,000
72.12 Skilled painter 3 Per 8 Hr. 2,000 6,000
73 Preparation/Updation of As-Built drawings like P&ID, GAD, Plot Plan, ISO, Alignment Sheet, Earth Pit Layout, Cable Root, Electrical Single Line Diagram etc. (including taking of required measurement from Site) after modifications(.with submission of editable Auto-Cad file and one printed copy) 0
73.02 GAD 3 Per Drawing 4,824 212617 14,472
73.03 Plot Plan 3 Per Drawing 4,824 212618 14,472
73.04 ISO 3 Per Drawing 4,824 212619 14,472
73.05 Alignment Sheet 3 Per Drawing 4,824 212620 14,472
73.06 Earth Pit Layout 3 Per Drawing 4,824 212621 14,472
73.07 Cable Route 3 Per Drawing 4,824 212622 14,472
73.08 Electrical Single Line Diagram 3 Per Drawing 4,824 212623 14,472
73.09 Hazardous Area Classification 2 Per Drawing 4,406 213478 8,811
73.10 Crossing drawing 2 Per Drawing 4,406 213479 8,811
74 Supply and replacement of Gland packings of Globe Valves (from 2" to 12" ). Gland Packing to be purchase from GTL Approved Vendor/OEM of Valve. 9 Nos. 1,307 501461 11,763
75 Servicing & Maintenance of EOT Crane (Overhead Crane) of up to 15 tonne capacity mentioned below for General Servicing & checking of Long Travel, Cross Travel & Hoist Mechanism including following activities 1) Checking of Travelling speed for LT,CT & Hoist. 2) Checking the condition of Main Hoist Wire Rope 3) Operational check for Gear box of LT,CT & Hoist to check the condition of Gears & Oil. 4) Cleaning & checking of Girder 5) Checking of Brake Disc/Brake Pads/Brake Liners 6) Checking of Push Button Controls, Operation of Motors, Variable Frequency Drives (VFD), Limit Switches, Breaking Resistors & Bus Bars. No separate charges shall be paid for manpower, consumables, tools & tackles used during execution of this activity. 1 Nos. 25,000 210929 25,000
76 Supply & replacement of C-rail festoon system of EOT crane 1 R Mtr 6,500 6,500
77 Supply & installation of FRP sheet(5 mm) as per thickness mentioned below of approved colour on roofing and sides of Metering system or DG Sets as per manufacturer’s instructions including providing sealant in the overlapping portion of sheets complete and including all accessories. Job includes removal of existing sheets if any. 200 Sq ft. 407 500679 81,400
78 Supply & installation of Teflon sheet as per thickness mentioned below for Pipe Support (Between pipe and Support) 0
79 PAUT Testing as per instruction of EIC and submission of report .The job shall be inclusive of coating removal as per the requirement of testing. Upon completion, the contractor shall submit a detailed inspection report, including scan data, flaw sizing, data analysis, and final engineering recommendations reviewed and signed off by an ASNT Level-III professional. 3 Location 49,531 211703 148,593
80 Supply, transportation, fabrication and erection of MS steel section (Frame) of various sizes along with required fasteners (plate, angle, tee, channel, beam etc) for installation of panel. Rate also includes the surface cleaning by a suitable method, Supply and application of two coat of high build chlorinated rubber / zinc phosphate primer and two coats of finished paint of epoxy of grey colour / colour as specified by GTL of approved make, the job is to be executed as per the direction of the GTL E.I.C. & GTL requirement. Job inclusive of labour, machinery etc.(No separate charges shall be paid for transportation of fabricated structure, manpower, equipment's used during execution of this activity) 300 per Kg 150 205425 45,000
81 Supply and application of Stanvac make Chemcoint RL 500 (Anti Corrosive Coating cum primer) Stanvac make 727 Stangard HP-PLPU (Golden Yellow Top Coat over Chemcoint RL 500 for long lasting corrosion protection) paint in A/G station piping / valves / fittings / etc. This includes surface preparation, tools, tackles, consumables, transportation, equipment, manpower, etc. required for execution of job. 400 Sq. Mtr. 4,280.00 1,712,000
82 Execution of emergency repair works on leaking underground pipelines or station piping by replacement with a pipe spool piece or by installation of a fully encircled split sleeve welded directly on the line pipe, conforming to ASME B31.8, API 1104, PNGRB. The scope of work includes: tracking and manual/mechanical excavation of trenches in all types of soil/strata to identify, isolate, and expose the burst or leaking pipeline section up to a maximum length of 12 meters; provision of continuous dewatering, trench cleaning, sturdy shoring, and strutting; implementing absolute fire-safety measures, including gas monitoring, deployment of fire tender, and securing safe permit-to-work conditions; lifting, loading, secure double-point transit, and unloading of GTL-issued line pipes and associated materials from designated stores within Gujarat to the work site; execution of hydro testing of the replacement spool pipe; cold cutting of the defective line pipe section from both ends up to a maximum single length of 12 meters; edge/bevel preparation, alignment, and fit-up inspection; conducting non-destructive testing (NDT) comprising 100% Radiography Testing (RT), Ultrasonic Testing (UT), and Dye Penetrant (DP) checking on all field/sleeve weld joints; surface preparation to SA 2.5 standard and application of field joint coating/wrapping (3LPE or equivalent anti-corrosive system); Holiday testing; backfilling of the trench in layers not exceeding 150 mm using approved backfill material, compacted to a minimum of 95% Proctor density; and full site restoration to its original profile. The rate is all-inclusive of all specialized equipment, cranes, welding machines, NDT gear, testing kits, consumables (including welding electrodes), specialized manpower, and overheads, excluding line pipes (issued from GTL at designated stores) and nitrogen purging, which shall be claimed under a separate standalone SOR item. 0
83 Dismantling & removing the existing installed equipment such as DG Set, Metering skid, Filter, Filtration skid, PRS skid, Pig Barrel, Pig Trolley, Jib Crane, Piping, electrical/ instrumentation panel, valves, structural steel etc. carefully including handling, loosing the nuts, bolt cutting etc(if required) and stacking the equipment's/ material within a radius of 250 Mts. and as directed by EIC. Manpower, Machinery required, transportation is in contractor's scope. 0
83.01 Item weight upto 501-1000 kg 1 Lumsum 23,430.00 23,430
83.02 Item weight upto 1 Ton - 2 Tonnes 1 Lumsum 27,463.00 27,463
83.03 Item weight upto 2-Tonnes- 3 Tonnes 1 Lumsum 29,537.00 29,537
83.04 Item weight upto 3-Tonnes- 5 Tonnes 1 Lumsum 36,709.00 36,709
83.05 Item weight upto 5-Tonnes- 10 Tonnes 1 Lumsum 48,070.00 48,070
84 Installation of equipment such as DG Set, Metering skid, Filter, Filtration skid, PRS skid, Pig Barrel, Pig Trolley, Jib Crane, Piping, electrical/ instrumentation panel, valves, structural steel etc. carefully including handling, erection and proper installation of the equipment's/ material within a radius of 250 Mts. and as directed by EIC. Manpower, Machinery required, transportation is in contractor's scope. 0
84.01 Item weight upto 50 kg 1 Lumsum 2,000.00 2,000
84.02 Item weight upto 51-150 kg 1 Lumsum 3,000.00 3,000
84.03 Item weight upto 151-250 kg 1 Lumsum 6,000.00 6,000
84.04 Item weight upto 251-500 kg 1 Lumsum 8,000.00 8,000
84.05 Item weight upto 501-1000 kg 1 Lumsum 14,000.00 14,000
84.06 Item weight upto 1 Ton - 2 Tonnes 1 Lumsum 27,463.00 27,463
84.07 Item weight upto 2-Tonnes- 3 Tonnes 1 Lumsum 29,537.00 29,537
84.08 Item weight upto 3-Tonnes- 5 Tonnes 1 Lumsum 36,709.00 36,709
84.09 Item weight upto 5-Tonnes- 10 Tonnes 1 Lumsum 48,070.00 48,070
85 Reversal of Spectacle Blind on installed A/G Piping for various sizes etc. including nut bolt loosening, gasket changing,valve operation, stud cleaning, tightening, and torque setting by torque wranch with all tools / tackles / manpower etc. of valves sizes:- 0
85.01 Up to & including 1” NB 1 Nos. 434.00 434
86 Fabrication and installation of Underground Casing Pipes IS-3589:2001 Fe-410/or IS2062 equivalent grade of different thickness or schedule. Job Includes transportation of free issued casing Pipe from GTL designated store to site, handling, Horizontal Cutting at both sides of Casing Pipes as well as Circumferential Cutting of Casing Pipes, bevelling /edge preparation of Longitudinal direction & Circumferential Direction, aligning, installation of Casing Insulators, Sand Filling, Mud Application, fit-up, tie-in, welding at both sides of pipes in longitudinal direction as well as Circumferential Joints, DP, temporary supporting etc. Bentonite Filling, Dewatering, Supply & installation of end seals & Painting of Casing Pipe. Excavation upto required depth & Back-filling of the same after successful completion is also included in the scope. All the tool & tackles, equipment's, hydra, mud pump and supply & installation of required size casing insulator, vent & drain pipes of suitable size shall be included in this SOR. (Supply and transportation of Casing Pipes are in scope of GTL & will be issued at designated GTL stores). Permission for excavation and Land / Corp compensation shall be in scope of GTL. 0
86.01 up to Casing Size 12" Dia. (Normal Soil) 1 R. Mtr. 34,029.00 34,029
86.02 up to Casing Size 12" Dia. (Rocky Soil) 1 R. Mtr. 36,431.00 36,431
86.03 Casing Size 16" Dia.(Normal Soil) 1 R. Mtr. 34,193.00 34,193
86.04 Casing Size 16" Dia. (Rocky Soil) 1 R. Mtr. 36,558.00 36,558
86.05 Casing Size 18" Dia. (Normal Soil) 1 R. Mtr. 36,625.00 36,625
86.06 Casing Size 18" Dia. (Rocky Soil) 1 R. Mtr. 39,288.00 39,288
86.07 Casing Size 20" Dia. (Normal Soil) 1 R. Mtr. 38,026.00 38,026
86.08 Casing Size 20" Dia. (Rocky Soil) 1 R. Mtr. 40,830.00 40,830
86.09 Casing Size 24" Dia. (Normal Soil) 1 R. Mtr. 41,142.00 41,142
86.10 Casing Size 24" Dia. (Rocky Soil) 1 R. Mtr. 44,256.00 44,256
86.11 Casing Size 30" Dia. (Normal Soil) 1 R. Mtr. 44,602.00 44,602
86.12 Casing Size 30" Dia. (Rocky Soil) 1 R. Mtr. 48,063.00 48,063
86.13 Casing Size 36" Dia. (Normal Soil) 1 R. Mtr. 48,449.00 48,449
86.14 Casing Size 36" Dia. (Rocky Soil) 1 R. Mtr. 52,293.00 52,293
86.15 Casing Size 42" Dia. (Normal Soil) 1 R. Mtr. 46,859.00 46,859
86.16 Casing Size 42" Dia. (Rocky Soil) 1 R. Mtr. 50,369.00 50,369
86.17 Casing Size 48" Dia. (Normal Soil) 1 R. Mtr. 85,942.00 85,942
86.18 Casing Size 48" Dia. (Rocky Soil) 1 R. Mtr. 94,876.00 94,876
87 Removal of gear box from Valve((Ball/Globe/Check), dismantling of Gear box, replacement of required packing, damaged bearings, proper cleaning, greasing of the same with Multipurpose grease & re-installation of gear box for various Valve sizes including supply of multipurpose grease, handling, packing materials, nut bolt loosening, gasket changing, Bearing changing (reputed make),valve opeation O-ring replacement with all tools / tackles / manpower etc. of different valves sizes . 0
88 Pre-commissioning/Operational cleaning pigging of GTL pipeline (including Criss-Cross Foam Pigs, Brush Pigs, Magnetic Scraper Pigs, and final High-Density Polyurethane Foam Pigs) to achieve a completely dry, debris-free pipeline conforming to ASME B31.8. Price includes supply of all specialized pigs, launcher/receiver operations, intermediate tracking, and disposal of extracted debris/black powder.debris analysis report as per GTL REQUIREMENT 0
88.01 8" dia pipeline 1 Per Km 6,347.00 6,347
88.02 12" dia pipeline 1 Per Km 5,150.00 5,150
88.03 18" dia pipeline 1 Per Km 5,200.00 5,200
88.04 24" dia pipeline 1 Per Km 3,500.00 3,500
88.05 30" dia pipeline 1 Per Km 3,600.00 3,600
88.06 36" dia pipeline 1 Per Km 4,000.00 4,000
89 HAZOP Study by independent HAZOP chairman of experienced agency. Prior to start the work, the contractor shall submit credential of HAZOP chairman for approval of GTL. 3 Per Day 43,789 211970 131,367
90 Gas cutting, grinding and welding of edges of chequered plate installed in cable trenches, valve pit etc. including handling. The job inclusive of all consumables, equipment's, tools, labour etc. 3 R. Mtr. 2,260.00 6,780
91 Greasing of under ground & above ground valves of size mentioned below with high pressure Grease/ pneumatic Sealant Gun( provided by GTL) under the supervision of GTL. This including Supply of manpower, nitrogen cylinder/air compressor, cotton waste for operation of pneumatic gun. No separate charges shall be paid for Manpower, Tools & Tackles, operation of valve for this activitiy. 0
92 Supply & installation of MS sheet, removal of existing sheet, if any. Powder coated, Color:Simense gray or Smoke gray or GI Sheet along with all accessories like studs & washers. No separate charges shall be paid for manpower, consumables, equipments, tools & tackles used during execution of this activity. 0
92.01 MS sheet 18 gauge 1 Sq. Mtr. 923.00 923
92.02 MS sheet 22 gauge 1 Sq. Mtr. 684.00 684
92.03 GI sheet 18 gauge 2 Sq. Mtr. 1,078.00 2,156
92.04 GI sheet 22 gauge 1 Sq. Mtr. 752.00 752
93 Supply & installation of SS sheet Cabinet (Removal of old SS Sheet Cabinet from Actuator Valve/Equipment, if any)conforming to IP65 for Actuator Valve/Any Equipment along with all provisions for cable entry, glands, accessories like studs & washers 0
93.01 SS sheet 18 gauge Upto 12"Valve 1 Nos. 20,000.00 20,000
93.02 SS sheet 18 gauge Above 12"Valve 1 Nos. 18,000.00 18,000
93.03 SS sheet 22 gauge upto 12"Valve 1 Nos. 20,000.00 20,000
93.04 SS sheet 22 gauge above 12"Valve 1 Nos. 18,000.00 18,000
94 Hydrostatic testing of double length Line Pipe (approx. 24 meter) at max. pressure of 150 brag. Job includes arrangement of Header/ Dish end (end cap) for installation of calibrated pressure gauge, water inlet, drain, vent; welding,NDT, cutting, bevelling and edge preparation after testig job. Submission of report after completion of hydrotest.This includes loading/unloading of linepipe, header/disc end preparation, tools, tackels, water, Pump, corrosion inhibitor, lifting equipment, manpower, etc. required for execution of job. 0
95 Supply, fabrication and installtion of Vent line Flapper(Brass) with perforated wiremesh in Brass material. The Job includes dismantle the vent pipe, cutting out existing Vent Flapper from vent line-if any, and refitting as found position after fabrication. No seperate charges shall be paid for manpower, dismantling spool, welding and refitting the same. Cosumable like Gasket shall be provided by GTL 0
96 Non-Destructive Testing (NDT) of pipeline and piping welds and base metal, inclusive of all tools, consumables, darkroom setups, and ASNT/ISNT Level II/III certified personnel, strictly conforming to API 1104, ASME Section V, PNGRB T4S, and OISD-STD-226 standards. Deliverables include detailed NDT reports and signed off by Level-III personnel. 0
96.01 Ultrasonic Thickness Gauging (UTG) of pipeline and station piping using calibrated digital A-scan/B-scan UT meters, including surface preparation and couplant application, executed on a minimum 4-point quadrant grid layout. 1 Location 5,000.00 5,000
96.02 Radiographic Testing (RT) of weld joints utilizing X-Ray crawlers (for mainlines) or Gamma sources (Iridium-192 for tie-ins/stations), using Class 1 fine-grain film and wire-type ASTM Image Quality Indicators (IQI), ensuring a minimum radiograph density of 2.0 to 4.0 per API 1104. 1 Inch Dia 2,100.00 2,100
96.03 Magnetic Particle Testing (MT) of ferromagnetic weld root/power-tool cleaned passes or fillet welds using an electromagnetic AC/DC Yoke and wet fluorescent or dry visible contrast media per ASME Sec V Art. 7. 1 Location 8,056.00 8,056
96.04 Liquid/Dye Penetrant Testing (PT) of non-ferromagnetic or alloy surfaces/weld joints using solvent-removable visible dye and developer kits conforming to ASME Sec V Art. 6. 1 Location 8,056.00 8,056
97 Ultrasonic Thickness Gauging (UTG) of pipeline and station piping using calibrated digital A-scan/B-scan UT meters, including surface preparation and couplant application, executed on a minimum 4-point quadrant grid layout. 1 Location 5,000.00 5,000
98 Supply & filling Rubble Soiling (200-250 mm thick) in trench, bottom of foundations for FML skid/piping supports etc up to required level complete as per drawings, specifications and as directed by EIC. No separate charges shall be paid for manpower, consumables, equipment's, handling, tools & tackles used during execution of this activity. 30 Sq. mtr 1,500 211773 45,000
99 Painting, Numbering & Lettering of existing pipeline markers and painting of vent pipes in cased crossings including Supply of paint and application of 2 coats of red-oxide primer and 2 coats of zebra strip (black and golden yellow stripes) of approved quality to give an even shade after proper scraping of existing paint and clearing of surface free from foreign materials. The rate are including man/ material and transportation to the position / site. 0
99.01 Vent Pipes 1 Sq. Mtr. 2,000 2,000
99.02 Direction Marker 400 Nos. 2,000 208825 800,000
99.03 Warning Marker 300 Nos. 2,000 208826 600,000
99.05 Aerial Marker 30 Nos. 2,000 60,000
99.06 OFC Marker 40 Nos. 2,000 80,000
99.07 Navigation Marker 20 Nos. 3,000 208828 60,000
99.08 RoU Boundary Marker 30 Nos. 500 15,000
100 Supply, transportation & installation of Navigation Marker (of size 5m X 2m with required channels for grouting) at River Crossing including painting, stencilling the logo, arrow markers & signs as per specimen drawing DRW. No. GTL-AMC-STD-10 enclosed. The Job includes supply of all materials for grouting in 1:3:6 PCC mixtures to correct line, level and direction. The work also includes transportation to site of installation, necessary excavation for grouting of post, cleaning ground portion from the ground level & restoration. 6 Nos. 55,000 210985 330,000
101 Supply, transportation and installation of new direction marker / warning Marker / Arial Marker / KM Marker on pipeline RoU as per DWG. No. GTL-AMC-STD-10 / GTL-AMC-STD-11 including supply of all materials for fabrication, cleaning, two coats of red-oxide and two coats of zebra colour (black and golden yellow strips) of approved quality (I S I Mark) paint and marking the number, direction, chainage and pipe size. Excavation up to required size, grouting in 1:3:6 PCC mixture to correct line, level and direction, back-filling & restoration. The work is to be executed as per drawing and direction E.I.C. No separate charges shall be paid for manpower, consumables, transportation, lifting equipment's, handling, tools & tackles used during execution of this activity. 200 Nos. 12,000 207220 2,400,000
102 Supply, Transportation and installation of new OFC Marker as per DWG. No. GTL-AMC-STD-05 including supply of all materials for fabrication, cleaning, two coats of red-oxide and two coats of zebra color (black and golden yellow strips) of approved quality (I S I Mark) paint and marking the number, direction, chainage and pipe size. Excavation upto required size, grouting in 1:3:6 PCC mixture to correct line, level and direction, back-filling & restoration. The work is to be executed as per drawing and direction E.I.C. No separate charges shall be paid for manpower, consumables, transportation, lifting equipments, handling, tools & tackles used during execution of this activity. 0
102.01 Type-I, For normal soil 3 Nos. 6,500.00 19,500
102.02 Type-III, For Rocky areas 3 Nos. 8,000.00 24,000
103 Supply, transportation and installation of new FRP direction marker / warning Marker with RCC pole on pipeline RoU as per DWG. No. GTL-AMC-STD-10 / GTL-AMC-STD-11 including supply of all materials cleaning, Excavation up to required size, grouting in 1:3:6 PCC mixture to correct line, level and direction, back-filling & restoration. The work is to be executed as per drawing and direction E.I.C. No separate charges shall be paid for manpower, consumables, transportation, lifting equipment's, handling, tools & tackles used during execution of this activity. 3 Nos. 5,500 213480 16,500
104 Supply, transportation and installation of pre-cast RCC (1:2:4) RoU boundary markers on pipeline RoU as per drawing No.- DWG. No. GTL-AMC-STD-04 or as per direction of E.I.C. The work also includes necessary excavation of pits, grouting of post & restoration. No separate charges shall be paid for manpower, consumables, transportation to site location, tools & tackles used during execution of this activity. 100 Nos. 1,500 205415 150,000
105 Cleaning of valve chamber / condensate pit including de-watering, cleaning of moisture content, sludge removal, cleaning with fresh water, drying of cleaned valve chamber or condensate pit and disposal of sludge and debris within a lead of 1 KM. 3 Per Chamber / PIT 1,961 210991 5,883
106 Providing stone pitching average 230-250mm thickness with the joints filled up with cement mortar of 1:6. Including preparation of the bed slope, cutting and filing earth, compacting to the 90% of proctor's density, filling the joints with 1:6 cement mortar pointing the joints with same mortar complete in all respects including the supply of stone boulders, all materials, labour and consumables etc. as directed by engineer-in-charge and as per the specifications. 50 Sq. Mtr. 2,000 208619 100,000
107 Supply and installation of concertina Razor wire to replace the existing damage portion fencing of dia. 500mm of GI barbed wire 12SWG in helical shape of wire to wire distance 250mm spacing in existing boundary wall with 8 nos(4 on each side) horizontal wiring at 45 degree spacing each as described in drawing. The 'Y' Steel Structure if used shall be claimed as per relevant SOR. New structure work includes sand blasting , primer and 2 coats of aluminium paint for structural work. 1000 R. Mtr. 1,200 102024 1,200,000
108 Supply and installation of Barbed wire( 6 Wire) fencing to replace the existing damage portion mm of GI barbed wire 12SWG in existing boundary wall. The Steel Structure if used shall be claimed as per relevant SOR. New structure work includes sand blasting, primer and 2 coats of aluminium paint for structural work and existing with single coal of aluminium painting 1000 R. Mtr. 200 102025 200,000
109 Washout repair job on existing buried pipeline, which occur mostly during monsoon period: Supplying and filling selected loose earth other than black cotton soil from borrowed pits in the washout/depressed land or in the pit locations of pipeline ROW compacting including cost of transportation, spreading, compacting, all as directed by engineer-in-charge. The rates includes royalty or any other levies by Govt. agencies towards taking of loose earth from borrowed area as per the direction of engineer-in-charge/site engineer inclusive all labour, materials, tools, tackles, transportation, taxes etc. completion all respect. (Payment shall be made on basis of measurement of the pit profile of the earth washout in the ROW) 800 Cu. Mtr 1,500 102027 1,200,000
110 Supplying and laying in position of RCC NP3 class pipes with collars, confirming to IS: 458 for pipe culverts, cable crossing, road crossing etc. including cutting the hume pipe if necessary, lowering, laying in position to proper levels, slopes etc. caulking the joints with spun yarn soaked in neat cement slurry and finishing with cement mortar 1: 2 (1 Cement: 2 Sand) curing etc. all complete as per drawings / specifications and directions of Owner/Owner’s Representative. Rate is included the cost of excavation up to 1.2-meter cover and backfilling of earth. Providing bedding concrete of PCC (1:4:8) 75 mm thick and backfilling with good earth 0
111 Rough plaster having 20 mm thickness 1:4 cement-mortar which includes groove of 15 to 25 mm Width X 15 mm Depth in plastering at all heights, levels and places, including scaffolding, chipping, roughing up the concrete , curing and finishing.The scope includes demolition of old plaster works and application of new plaster works having thickness of 20 mm. 200 Sq. mtr 318 212090 63,600
112 Water body Bank protection: By Supply of material and construction of Gabions if the sloping side of the water crossing & embankments is between 10 and 45,the gabions mattresses will be constructed by works include, fabricate hexagonal mesh of opening of size 100x120 mm made of 3.0 mm dia galvanized steel wires with all selvedges finished with 4.0 mm dia galvanized wires. Gabions mattresses unit i.e. diaphragms of size 2 m x 25 cm thick with length varying from 4.0 m to 6.0 m as per site requirements. In any case, mattresses length will not be more than 60 m. Mattresses shall be filled using solid hard rock boulders (grade from 75 mm to 150 mm) overfilling up to 40 mm will have to be done to allow for settlement. Gabions mattresses diaphragms shall be laced laid and placed at required locations as per detailed approved drawing. 30 Cu. Mtr. 7,500 212223 225,000
113 Supply and installation of laminated plywood sheet up to 10mm thick in doors, windows as per applicable colour as per direction of EIC. 3 Sq.Mtr 2,452 212118 7,356
114 Supply, installation, testing and commissioning of UPVC, male or female threaded isolation valve (Handle Valve), with necessary fitting etc., to complete the job. Job is also inclusive of plaster braking (FOR external / internal work)(SCH 80 ASTM ) 0
115 Dismantling of damaged tiles from building including stacking of serviceable materials and disposal of unserviceable material within 100 mtr lead. The job including temporary covering of panels / equipment's installed in room with Polythene sheet of contractor material. 3 Sq. Mtr 250 212145 750
116 Removal of excavated sand / debris/soil and disposal of material from specified location up to 5 Kms of area 10 Cu. Mtr 250 212146 2,500
117 Providing and fixing Indian style W/C of reputed make complete with connection to sanitary. Rate shall include all plumbing work cost inclusive of all necessary items to complete the job as directed by Engineer – in – charge 20 Nos. 8,500 212148 170,000
118 Providing and fixing European style W/C of reputed make complete with connection to sanitary. Rate shall include all plumbing work cost inclusive of all necessary items to complete the job as directed by Engineer – in – charge 40 Nos. 10,000 212149 400,000
119 Providing and fixing Flush tank complete with connection to sanitary W/C line. Rate shall include all internal plumbing cost inclusive of all necessary items to complete the job as directed by Engineer-in-charge 60 Nos. 3,541 212150 212,460
120 Providing & fixing in position 15 mm C.P. brass bib cocks. 20 Nos. 2,452 212964 49,040
121 Providing & fixing in position 15 mm C.P. brass swivel (swinging) sink cocks. 20 Nos. 2,452 3000585 49,040
122 Providing & fixing in position 15 mm C.P. pillar cock with connecting pipes ,nuts washers, etc complete. Pillar Cock - long neck with Aerator, if required. 20 Nos. 925 213216 18,500
123 Providing & fixing 15mm C.P. brass angle valve with C.P. copper connecting pipe 450 mm long and nuts, washer and brass flange complete, including cutting and making good the wall where required. 20 Nos. 925 212160 18,500
124 Providing & fixing flush valve with necessary fittings. 10 Nos. 2,398 212161 23,980
125 Providing & Fixing Jet Spray/Hand faucet – with all fittings & fixtures. 60 Nos. 599 212162 35,940
126 Providing & fixing of concealed stop cock with wall flange and necessary pipes and fittings etc. complete., for the following sizes. Stop Cock. 0
127 Waterproofing of the terrace of CR/Guard Room building, including terrace cleaning, crack filling, chemical wash, application of one layer of cement chemical(SBR latex) with fiber mesh, followed by putty and an additional layer of cement chemical. Final coating of SBR latex chemical shall be applied on top. Waste generated shall be disposed of in the nearby designated area with prior permission of GTL. The SOR also includes a 24-hour pond test after job completion. 100 M2 1,200 213482 120,000
128 Transportation of Scrap material (Hazardous Waste, batteries, Structural Steel, Plastic, GI Sheets, UPVC Sheets, Wooden Scrap etc. ) from various GTL terminals up to Scrap yard/Designated Terminal within Base as directed by engineer-in-charge. The job includes loading of material in vehicle, transportation abiding all safety precautions and unloading at designated places. The Vehicle shall be as per the weight & volume of scrap material which shall be pre-identified jointly by GTL & Contractor. No extra charges shall be paid for Manpower, Equipment's etc. for loading & unloading of the material. 0
129 Supply and installation of Warning Board / Notice Board including stencilling the Warning Write ups, logo, arrow markers & signs; to be installed at identified locations as per the specimen drawing enclosed including supply of all materials for grouting in 1:3:6 PCC mixtures to correct line, level and direction. The work also includes transportation to site of installation, necessary excavation for grouting of post, cleaning under ground portion up to 300 mm height from the ground level. No separate charges shall be paid for manpower, consumables, lifting equipment's, handling, tools & tackles used during execution of this activity. Standard drawing shall be provided by GTL 3 Nos. 27,013 212856 81,039
130 Requirement of Structural Civil Engineer at GTL Sites /station. This job is inclusive of site visit for issuing of structural stability certificate of existing GTL site(Viz GTL building , process area piping support etc) .During the site visit any abnormality/irregularity observed then recommendation report for the mitigation requirement with drawing ,BOM etc. to be submitted to GTL. 3 Per visit 10,000 212877 30,000
131 Installation of safety signage’s board (4 mm ACP sheet with High quality radium eco solvent sticker with gloss lamination) 3 Sq.Feet 2,369 212884 7,107
132 Providing and installation of radium eco solvent sticker with gloss lamination for safety boards, station Piping,Pole,JB etc 3 Sq.Feet 2,369 212885 7,107
133 Supply and uniformly application of Molykote 1000 Solid Lubricant Paste (or approved lead-/nickel-free equivalent) to all flange fasteners following thorough wire-brush cleaning and solvent degreasing. 3 Per Kg 8,056 212888 24,168
134 Supply and Installation of HDPE water pipelines including fittings as mentioned below sizes in control room building / terminal at damaged locations. No separate charges for plumber shall be paid. 0
134.01 2" HDPE Pipe Size & Fittings 1 R. Mtr 500 213487 500
134.02 4" HDPE Pipe Size & Fittings 1 R. Mtr 600 213488 600
135 Supply and installation HDPE fittings in water pipeline at damaged location. No separate charges for plumber shall be paid. 0
136 Earth work in excavation, site grading in all kinds of soil including soft rock in any plan dimension including disposal of excavated surplus and unserviceable earth up to any lead in all conditions. Soil to be levelled and neatly dressed complete in all respect as per scope of work, as per detailed construction drawings, as per technical specifications and directions of the Engineer-in-charge. Cu mtr. 0
136.01 Soft soil upto 2.5 meter 1 Cu. Mtr. 329 329
136.02 Below 2.5 meter 1 Cu. Mtr. 396 396
136.03 Hard rock upto 2.5 meter 1 Cu. Mtr. 926 926
136.04 Hard rock below 2.5 meter 1 Cu. Mtr. 1,204 1,204
137 Demolishing brick work at all heights including staking of serviceable materials and disposal of unserviceable material within 1KM lead including transportation/labour etc. 3 Cu. Mtr. 1,505 102023 4,515
138 Demolishing of RCC work by using mechanical breaker / Hammer / Manually / abrasive cutting machine including stacking of steel bars and disposal of unserviceable material within 1 KM lead with all tools/tackles/equipment/machinery/labour etc. 3 Cu. Mtr. 2,842 101897 8,526
139 Breaking of PCC from damaged floor by using mechanical breaker / Hammer / Manually / abrasive cutting machine and disposal of the demolished materials within a lead of 1 KM. 3 Cu. Mtr. 1,666 100124 4,998
140 Back-filling of available excavated earth (excluding rock) in trench, sides of foundation etc in layers not exceeding 20 cm in depth consolidating earth deposited layer by ramming and watering, lead up to 100 Mtr. and filling up to required Ground level. No separate charges shall be paid for manpower, consumables, equipment, handling, tools & tackles used during execution of this activity. 3 Cu. Mtr. 223 211771 669
141 Supplying and filling Sand in 150 mm thick layers watering, rolling, ramming, consolidating and dressing the surface including cost of sand (Zone-II/Zone-III sand only) complete in all respect as per scope of work, detailed construction drawings as per technical specifications and directions of the Engineer-in-charge. 3 Cu. Mtr. 1,620 213498 4,860
142 BRICK WORK IN SUB STRUCTURE 0
142.01 Providing and construction and handing over brick masonry work with brick class designation M-7.5 of IS:1077 in Cement Mortar 1:4 (1cement : 4 coarse sand) below DPC including weep holes, plastering of 15 mm thickness in CM 1:4 on exposed surfaces, mud mat, excavation and backfilling with serviceable earth, complete in all respects as per scope of work, detailed construction drawings, technical specifications and direction of Engineer-in-charge. 3 Cu. Mtr. 6,372 213499 19,116
143 BRICK WORK IN SUPER STRUCTURE 0
143.01 Providing and construction and handing over brick masonry work with brick class designation M-7.5 of IS:1077 in Cement Mortar 1:4 (1cement : 4 coarse sand) in superstructure plastering of 15 mm thickness in CM 1:4 on both the faces complete in all respects as per scope of work, detailed construction drawings , technical specifications and direction of Engineer-in-charge. 3 Cu. Mtr. 7,683 213500 23,049
144 PLAIN CEMENT CONCRETE 0
144.01 Providing, laying in position, construction and handing over of PCC Grade of 1:3:6 (M-10) in all types of concrete works including levelling courses below foundations, mass concrete works, chambers, cable trench, under floors and any other locations (which are not covered as part of respective items of SOR), at all levels and locations etc complete in all respects as per scope of work, detailed construction drawings, technical specifications and direction of Engineer-in-charge. 15 Cu. Mtr. 5,508 213501 82,627
145 Providing and laying RCC (reinforced cement concrete) of grade M-20 with 20mm and down grade crushed stone aggregate in all types of sub-structures like foundations, beam, columns, pedestals, pedestal bases, cable trench, RCC retaining wall foundation for boundary wall including construction joints, bitumen painting on surfaces in contact with soil, shuttering, supplying and fixing MS inserts/bolts,conduits,precast covers, finishes etc. at all depths and levels complete as per drawings, specifications and directions of the Engineer-in-charge. 15 Cu. Mtr. 7,593 213502 113,895
146 Providing and laying RCC (reinforced cement concrete) of grade M-25 with 20mm and down grade crushed stone aggregate in all types of sub-structures like foundations, beam, columns, pedestals, pedestal bases, cable trench, RCC retaining wall foundation for boundary wall including construction joints, bitumen painting on surfaces in contact with soil, shuttering, supplying and fixing MS inserts/bolts,conduits,precast covers, finishes etc. at all depths and levels complete as per drawings, specifications and directions of the Engineer-in-charge. 15 Cu. Mtr. 7,872 213503 118,080
147 Supplying and Fabricating and Fixing in position HYSD Steel Reinforcements/ TMT Grade Fe-500/550 conforming to IS1786-1985 at all levels and positions including the Cost of transport, Straightening, Cutting, Bending, Cranking, Binding, Welding, Provision of necessary Chairs and Spacers, Preparation of bar bending schedule and getting the same approved by EIC etc., complete as per Drawings and Specifications and including Cost of binding wire, Labour etc., all complete in all respects as per scope of work, detailed construction drawings, technical specifications and direction of Engineer-in-charge. The chairs and spacer bars provided will not be Measured for payment. 3000 Kg 96 205438 288,000
148 Cleaning of underground/overhead water tank pit deploying all necessary equipment, manpower etc. including de-watering, sludge removal, disinfection using chlorine or potassium permanganate, cleaning with fresh water and disposal of sludge and debris within a lead of 1 Km. (by involving professional agency) 3 Nos. 5,000 212070 15,000
149 Cleaning of Soak Pit/ Septic Tank/ SEVER/Mud Pit with its associated system including removal of sock/mud, dewatering, removal of chocking if any, debris and disposal of the same to the distance of 10 Km, cleaning with fresh water including tools/tackles/transportation/material/labour etc., 3 Nos. 9,500 212071 28,500
150 FLOORING WORKS 0
150.01 Providing and laying vitrified floor tiles in different sizes 3 Sq.Mtr 1,066 213506 3,198
150.02 Providing and fixing 1st quality ceramic glazed floor tiles 3 Sq. mtr 1,067 212097 3,201
151 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut Granite 3 Sq. mtr 7,670 213507 23,010
152 Providing and fixing 10 mm thick acid and/or alkali resistant tiles 3 Sq. mtr 1,719 212095 5,157
153 Supplying and laying of Cement Concrete inter locking paver block 80 mm thick, I shape or as per GTL or any other approved shape, rough finish, M-40 compressive strength of approved brand laid over the sand bed of minimum 100 mm thick. The CC interlocking blocks to be of uniform Grey colour or as approved by EIC complete in all respects as per scope of work, detailed construction drawings, technical specifications and directions of the Engineer-in-charge. 3 Sq. Mtr 1,095 212087 3,285
154 Providing and laying 12 mm thick cement plaster on walls, RCC beams, columns and chajja etc of mix 1:4 ( I cement, 4 fine sand) including making of typical grooves drip-course including hacking of RCC roof beams and columns surfaces and curing etc. The job includes the cost of supplying and fixing of chicken wire mesh at every joint of brick masonry and RCC before commencing the plastering work complete in all respect as per scope of work, detailed construction drawings , technical specifications and directions of the Engineer-in-charge. 3 Sq . Mtr. 290 205434 870
155 Supplying and applying 2 coats of reputed paint / Weather coat / Weather shield on external walls surfaces in approved colour at all heights as per scope of work and recommendations of manufacturer including surface preparation, primer putty etc. detailed construction drawings , technical specifications and directions of the Engineer-In-Charge. 1500 Sq.mtr 264 213508 396,000
156 Enamel painting of interior wall of building, providing & applying acrylic emulsion paint of required shade and quality including the preparation of surface for painting, applying primer and 2 coats of acrylic emulsion paint as directed by EIC including temporary covering of panels / equipment installed in room with Polythene sheet. 1500 Sq Mtr 233 212068 349,500
157 Snow-cem painting of exterior wall finishing walls with water proof cement paint, at all heights, with 2 or more coats of approved shade and approved brand and quality such as “super snow-cem” or equivalent approved brand on Rough wall surfaces, which includes rough plaster, sand face and brick face surfaces to give an even shade including scaffolding and preparation. 1500 Sq Mtr 119 102220 178,500
158 Painting of Above Ground Civil Supports/Foundations/Earth Pits etc. (Existing/Newly Constructed) including Paint (Terra cotta), equipment for application & its accessories, manpower, material etc up to required surface finish. 1500 Sq. Mtr. 194 211572 291,000
159 Providing and fixing FRP Plain Sheet of 2.00 mm thickness in Plain profile of approved colour on roofing and sides as per manufacturer's instructions including cost of sealant in the overlapping portion of sheets complete and all accessories. 1 Sq. mtr 1,092 212179 1,092
160 ROU PROTECTION WORKS IN CASE OF EXPOSURE / SOIL EROSION 0
160.01 Random rubble masonry 1 Cu mtr. 3,000 213509 3,000
160.02 Supply & Filling Empty Cement Bags 50 Kg Capacity with sand with sand cement mixture (10:1) 150 Nos. 140 3000640 21,000
161 Supply and installation of GI Chain link fencing with hole size of 50 mm .Job is inclusive of removal exsiting damage chain link if requied. 30 Sq. Mtr. 1,043 102026 31,290
162 Alluminium WINDOWS & Door 0
162.01 Supply and Application of Good quality Sun Film of ISI mark, black colour on plain float glass. 3 Sq. feet 100 212107 300
162.02 Providing and fixing of window & door hinges with necessary fittings materials 2 Nos. 402 213510 804
162.03 Providing & fixing of sliding window lock with necessary fittings materials 2 Nos. 402 213511 804
163 BUILDING REPAIR & MAINTENANCE 0
163.01 Supply&Fix Alum Door Section thk 2.5mm 3 Sq. Mtr. 5,865 212103 17,595
163.02 Supply&Fix Alum Window Section Thk2.5mm 2 Sq.Mtr. 5,865 212104 11,730
163.03 Provid&Fix Float Glass Window etc 6mm Thk 3 Sq.Mtr. 2,645 213513 7,935
163.04 Provid&Fix Overhead Hydraulic Door Closer 3 Nos. 1,268 212109 3,804
164 Removal of damaged false ceiling from the position and disposal of the same within a lead of 500 meters and fixing new false ceiling of asbestos in place/ in position of old ceiling. 10 Sq. feet 212 212176 2,120
165 Supply of utility water suitable for sanitation purpose, plantation and gardening at designated locations of stations in tanker The job including filling of water in tanker, transportation, handling and transferring to U/G water tanks of GTL 0
166 Hiring of JCB for doing any normal/emergency excavation. Contractor shall submit fitness certificate of the equipment. The period of hiring will start after the equipment reaches at site and ends when equipment leaves the site. Break down period of equipment will not be paid. Maximum working time per day will be 8 Hrs. Rate for idle time of JCB shall be 50%. (Note: No separate payment shall be made for the quantity of excavation done.)Hiring rates is inclusive of diesel, operators, maintenance and transportation cost etc. 3 Per Hrs. 2,000 213515 6,000
167 Supply & filling empty Geo textiles bags of 50 kg capacity (the bags to be used in good condition only) by using sand and stitching by using jute threads and placing in position in RoW as directed by engineer-in-charge /Site Engineer. No separate charges shall be paid for manpower, machinery, consumables, transportation to site location, tools & tackles used during execution of this activity. 3 Nos. 250 750
168 Stenciling, numbers ,logos , arrow and letter writting including required background ( 2 coats )Painting. Job including supply of fluorescent/ highlighted paint/ acrylic emulsion/ oil paint of approved brand as per the approved vendor list and quality wherever required as per directed by GTL EIC. 300 Sq ft 350 105,000
169 2 coats application of Stenciling ,letter writing & Logo ets at all height of control room building & security Guard cabin. Job inclusive of Supplying & application of 2 coats of primer with 2 coats paint of as per the direction of EIC.Scaffolding ,ladder ,safety belt & required PPE in the scope of contractor. 150 Sq.Mtr 1,750 262,500
170 Providing and laying anti-skid vinyl flooring sheet 2.5 mm thick over base floor. 3 Sq.Mtr 517 212211 1,551
171 Supply, transportation & installation of reputed UPVC/PVC water tank with cover of different sizes with replacement of old one at required location including all necessary fittings, & accessories. 0
171.01 500 ltr Water Capacity 2 Nos. 7,280 212187 14,560
171.02 1000 ltr Water Capacity 2 Nos. 14,000 212188 28,000
172 Supply and replacement of 1/2" to 01" UPVC elbow/coupler/tee for water pipeline works 3 Nos. 413 213520 1,239
173 Providing and fixing Gypsum board false ceiling of 12.5 thick ,Gypsum board of tile size (610 x 610) mm weight of tile shall be 8.00 (kg/m2) suspended from RCC ceiling fixed with the help of (125 x 38) mm rowl plug and hanged with 5 mm thick galvanised hangers. Tiles shall rest over aluminium frame of (25 x 38) mm main and t @ 610 mm c/c including providing and fixing aluminium angle of size (25 x 25) mm all around the wall including all labours, material, scaffolding, screws, nails, hire charges of drill machine or any other material required for satisfactory completing of work and as per direction of EIC. 2 Sq. Mtr. 2,450 213521 4,900
174 Survey for Sub surface gas detection along the pipeline RoU. Report should be submitted in GTL approved format. 1 kms 400 213522 400
175 Painting of both side of Chain link fencing and its supporting structure: including Supply of paint and application of 2 coats of aluminum paint of approved brand as per the approved vendor list and quality as per the approved vendor to give an even shade after proper scrapping of existing paint (upto the maximum possible extent )and cleaning of surface free from foreign materials including labour and transportation etc. 1 Sq Mtr 152.00 152
176 Dismantling of damaged Chain Lnik fencing & Barbed wire fencing & disposal of unserviceable material within 5KM of GTL store 1 Sq Mtr 130.00 130
177 Providing & laying / spreading good quality gravel of 25 mm to 40mm over compacted sub base including preparation of sub base using selected earth whenever required & rolled to proper grading, compacting, Etc. complete as per good engineering practices & as directed by EIC. 1 Cu. Mtr 2,500.00 2,500
178 Supply & laying / spreading rounded good quality gravel of 40mm metal ( spread 100mm thick) with bottom 40micron thick polythene sheet and less over compacted sub base including preparation of sub base using selected earth, whenever required & rolled to proper grading, compacting, etc. complete as per good engineering practices & as directed by EIC. 1 Cu. Mtr 2,500.00 2,500
179 Supply, transportation and installation of End stoppers for Pavers blocks of thickness 100mm all around each block, filling joints with cement mortar 1:4 (1 cement: 4 sand) including preparation of sub grade, dressing curing of joints etc. complete as per drawings specifications and direction of Owner/Owner's Representative. (PCC charges shall be as per SOR of PCC mentioned elsewhere in this SOR) 1 Sq. feet 1,500.00 1,500
180 Providing and fixing double action hydraulic floor spring of approved brand and manufacture (conforming to IS: 6315) for Aluminium doors including cost of cutting floors as required, embedding in floors and cover plates etc. complete as per the direction of Owner/ Owner’s Representative. 1 Nos. 6,000 213403 6,000
181 Providing and fixing Aluminium handles anodized 125 mm (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 1 Nos. 150.00 150
182 Repairing of floor spring of the rooms which includes repalcement of internal parts etc. 1 Nos. 1,000.00 1,000
183 Supply of material and fixing of MS door of Section thickness of 2.5 mm, 4 x 1.75” pipe framing, 4 1/2” door top, middle & bottom, 5mm clear float glass with floor spring/ hinge, glazing clip, neoprene rubber gasket, lock, handle, tower bolt including all standard accessories. The frame shall be powder coated black colour. The job include all necessary items require to be fitted to complete the door installation, handling, transportation, manpower, etc 1 Sq. Mtr. 3,500.00 3,500
184 Supply & Installation of wrought iron or M.S. wheel/roller of Main Gate of terminals and fixing and fitting of the same with necessary clamps/ nuts/bolts and erection of the same. 1 Nos. 1,000.00 1,000
185 Greasing, oiling or repairing of rolling shutter 1 Nos. 1,500.00 1,500
186 Supply and installation of Fiber sheet upto 10mm thick in doors, windows as per applicable colour as per direction of EIC. 1 Sq.Mtr 2,000.00 2,000
187 Supplying and laying in position PVC pipes Class I conforming to IS: 4985 with all fixtures / fittings for cable crossings, Rain water collection for warehouse & shed etc. including cutting the pipe if necessary, lowering / erection in position to proper levels, slopes etc. providing proper jointing including clamping, Elbow,coupler and Valve and other fittings as per code requirements of manufacturers recommendations etc. all complete as per drawings, specifications and directions of Owner/ Owner’s representative. Separate plumbing charges shall not be applicable. 0
187.01 for size 15mm to 50mm pipe dia. 3 R.Mtr 201.00 603
187.02 for size beyond 50mm to 100mm pipe dia. 1 R.Mtr 495.00 495
187.03 for size beyond 100mm to 200mm pipe dia. 1 R.Mtr 1,412.00 1,412
188 Providing fixing, testing and commissioning in position UV stabilised PVC SWR PIPE of reputed make as per IS:13592 Class-b, including excavation incase of under ground and jointing with Tee shaped rubber seal ring confirming to IS : 5383 & with PVC Adhesive Solvent, including fitting like elbows, collors, tees, unions, couplers, reducers, enlargers, bends and all other required fittings for water facility inside terminal 0
189 Supply and Repair GI / PE Pipe 1/2" to 1 1/2" of dia including excavation in case of underground/Aboveground and restoring after repair/replacement upto the depth of 05 Mtrs. Job includes plumbing, men, material and transportation etc. 50 Mtr 1,000.00 50,000
190 Supplying, installing, testing & commissioning glazed european water closet with seat cover (ivory colour, wall mounted,with 'P' Trap with SWR selfit soil pipe and plug bend as per specs, with grouting the rubber gasket, connecting pipes etc.complete. (Reputed make) 7 Nos. 5,729 212152 40,103
191 Providing and laying False Flooring consisting of base plate 100x100 mm, 3 mm thick including stiffeners, folds with 6mm dia dash fasteners fixed with 10 ID 3 mm thick MS Pipe STUD. The STUD shall be provided with MS check not including 3 mm MS Ring welded for supporting the base including stiffeners under Jack head, 1.2 mm thick MS bottom tray, supporting the 18 mm thick medium density fiber board (Exterior grate as per IS: 12406) Panel faced on top with antistatic PVC tiles / High pressure laminate and MS tray at bottom as per standard drawing-no.GTL-AMC-STD-22. Rate shall include skirting to match with flooring as per standard drawing. The scope includes removal of existing false flooring, dispose of old false floorings to client's scrap yard. 10 Sq. Mtr. 2,000.00 20,000
192 Supply and lay of Polythene sheet for process area. 0
193 Supply and Installation of UPVC water pipelines inlcuding fittings as mentioned below sizes (Astral Make, Finolex Make, Prince Make, Ashirvad Make) in control room building / terminal at damaged locations. No separate charges for plumber shall be paid. 0
193.01 1/2" UPVC Pipe & Fittings 3 R. Mtr 759.00 2,277
193.02 1" UPVC Pipe Size & Fittings 3 R. Mtr 759.00 2,277
193.03 1.5" UPVC Pipe Size & Fittings 3 R. Mtr 848.00 2,544
193.04 2" UPVC Pipe Size & Fittings 3 R. Mtr 938.00 2,814
194 Dismantling and taking out of submersible pump-motor of rating 3KW / 5 KW from bore well, retaining and rolling of power cable pulled out from bore well. And reinstallation of repaired motor and associated assembly back into the bore in complete working condition. The rate for repairing of damages in the system shall be paid as per list below. All the tools tackles, manpower, tripod, fasteners etc. required for the job is included in the scope. 0
194.01 Rewinding including bearing bushing etc. 3/5 KW 3 Nos. 6,000 208958 18,000
194.02 Rewinding above 5KW to 15 KW 1 Nos. 11,793 11,793
194.03 Rectification/Replacement of mechanical damage of pump 3 Nos. 8,040 208960 24,120
195 Supply and installation of Submersible Pump (3HP) with motor assembly of Approved Make as per the GTL Vendor list attached with this tender (KSB, Lubi,or equivalent make) 0
196 Supply & replacement of starting capacitor for 1-phase submersible pump set ( 250 mfd) 1 Nos. 933 208976 933
197 Supply & Installation of Bore-well Starter Single-Phase up to 5kw. Starter should be with in-built over load tripping feature. 1 Nos. 4,642 208977 4,642
198 Supply & Installation of Bore-well Starter Three-Phase up to 5 Kw. Starter should be with in-built over load tripping feature. 1 Nos. 6,369 208978 6,369
199 Supply, Transportation and Installation of lighting Pole of reputed make confirming IS 2062/IS 1161 material of GI pipe of height approximately 5 to 12 Meter including re-installation of existing luminaire, JBs, Earthing connection, cable connection etc. on new pole as per GTL approved drawing 0
200 Supply & installation of Copper earthing cable 16 sq mm. The job includes the excavation, removal of existing Copper Strip, laying of new cable, back-filling & restoration. No separate charges shall be paid for manpower, tools & tackles, equipment's, instruments used during this activity. 30 R. Mtr. 483 210780 14,490
201 Collection of hazardous wastes including used engine oil, gear oil, hydraulic oil, turbine oil, compressor oil, transformer oil ,spent oil, filter elements, grease contaminated cotton waste etc. from GTL stations and disposal-off the same to an approved CPCB / GPCB vendor by complying Hazardous Waste (Management and Handling) Rules, 1989. 3 Kg 154 208680 462
202 Supply, installation testing & commissioning of Copper earthing: the job includes: a) Excavation of a pit of size (900 mm x 900mm x 3500mm deep) b) placement of Copper earth plate (600mm x600mm x3 6mm) and embedding the GI pipe of 20mm, 3Mtr. length in the earth c) back filling the pit with alternate layers of approx. 100Kg Charcoal and 50 Kg salt to cover the earth plate The pit shall further be refilled with earth up to ground level and compacted. Copper Strip (Size 25mm X 3 6mm) 2 nos. shall be provided from plate electrode to ground level to facilitate jointing with earth wire. It shall be provided with test link for testing of the particular earth pit. The funnel shall be installed above the ground for facilitating pouring of water. The funnel of earthing pits shall be covered by brick masonry chamber (Size 900mm x 900 mm x 600mm) with cement plaster on inside and outside. The chamber shall be provided with a hinged MS cover and frame fixed on chamber alognwith tagging on MS plate (400x100mm). The resistance of the pit must be achieved below 1 ohm 3 Nos. 25,000 213110 75,000
203 Supply, Installation, Testing & Commissioning of GI Pipe Earthing. A Pit (Size : 3500 mm deep) shall be excavated by auguring or otherwise, 65 dia GI pipe 3.5 Mtr. length shall be put. The GI pipe shall be cut tapered at the bottom and provided with holes of 12 mm dia. drilled at 75 mm interval up to 2.5 Mtr. length from bottom.The pit shall be back filled with alternate layers of appx 100 kg of charcoal and 50 kg of salt. The Pit shall further be refilled with earth up to ground level and compacted. GI Strip size 50x12mm shall be welded to this GI Pipe at ground level to facilitate jointing with earth wire. It shall be provided with test link for testing of the particular earth pit. The funnel shall be installed above the ground for facilitating pouring of water. The funnel of earthing pits shall be covered by brick masonary chamber (Size 900mm x 900mm x 600mm) with cement plaster on inside and outside. The chamber shall be provided with a hinged MS cover and frame fixed on chamber along with tagging on MS plate (400x100mm). The resistance of the pit must be achieved below 1 ohm. 3 Nos. 20,000 213111 60,000
204 Supply, installation testing & commissioning of Copper bonded earthing, Chemical Maintenance Free with 3 mtr length of min. 80 mm dia., coating thickness of min. 100 micron , Copper pipe (min. 3.6 mm thk) with pit dia of min 200 mm including installation of pit with cover. Separate charges will not be paid for excavation, backfilling, manpower, tools & tackles, consumables used for this activity.Earth Pit 16 Nos. 29,293 213112 468,688
205 Supply, installation testing & commissioning of GI earthing, Chemical Maintenance Free Earth Pit with 3 mtr length of min. 80 mm dia., coating thickness of min. 100 micron hot-dip galvanized, GI pipe (min. 3.6 mm thk) with pit dia of min 200 mm including installation of pit with cover. Separate charges will not be paid for excavation, backfilling, manpower, tools & tackles, consumables used for this activity. 21 Nos. 21,069 213113 442,449
206 Supply, Laying & Installation of Copper earthing strip – 25 x 3 mm (Above ground / Under Ground) with over lapping of minimum 75 mm at joints and two consecutive strip be bolted together with copper bolt., Job includes cutting the strip suitable to site, edge preparation , excavation of required length, strip laying and back filling after completion , site welding and bending and termination as per EIC, supply of connection bolts etc. 150 Mtr. 575 500747 86,250
207 Supply, Laying & Installation of Copper earthing strip – 50x 6 mm (Above ground / Under Ground) with over lapping of minimum 75 mm at joints and two consecutive strip be bolted together with copper bolt., Job includs cutting the strip suitable to site, edge preparation , excavation of required length/depth, strip laying and back filling after completion , site connection welding and bending and termaination as per EIC, supply of connection bolts etc. 300 Mtr. 2,000 600,000
208 Supply, Laying & Installation of GI earthing strip – 25 x 3 mm, (Above Ground) with over lapping of minimum 75 mm at joints and two consecutive strips to be welded together and applying bitumen on the joint. Separate charges will not be paid for excavation, backfilling, manpower, tools & tackles, consumables used for this activity. 30 Mtr. 210 500748 6,300
209 Supply, Laying & Installation of GI earthing strip – 50 x 6 mm, (Above Ground /Under Ground) with over lapping of minimum 75 mm at joints and two consecutive strips to be welded together and applying bitumin on the joint. Separate charges will not be paid for excavation, backfilling, manpower, tools & tackles, consumables used for this activity. 30 Mtr. 400 12,000
210 Supply, Laying & Installation of GI earthing strip – 25 x 3 mm, (Under Ground) with over lapping of minimum 75 mm at joints and two consecutive strips to be welded together and applying bitumen on the joint. Separate charges will not be paid for excavation, backfilling, manpower, tools & tackles, consumables used for this activity. 30 Mtr. 210 500749 6,300
211 Replacement of concrete/ MS/precast bid material plate /covers of Earth Pits by hinged acrylic covers with locking/bolting facility & with facility to change testing date. The related modifications of massonary works of Earth pits shall be in the scope of the contractor. 1 Nos. 2,569 210787 2,569
212 Supply and Installation of LED tube light having 20W Al body T8 Tube Rod with colour temp. 6500K of reputed makes 30 Nos. 1,228 211619 36,840
213 Checking & maintenance of indoor & outdoor lighting. Replacement of component will be paid as per separate SOR 30 Per station 3,000 90,000
214 Supply and Replacement of LED Tubes/ Lamps/Lights of reputed make including scaffolding, men, machinery if required as per EIC. Job includes installation on pole (up to 12 mtr height) or terminal building including SS nut bolts, termination, removal of old fixture etc. No separate charges shall be paid for manpower, consumables, lifting equipment's, handling, tools & tackles used during execution of this activity. 0
214.02 18 w Four/Two Pin LED 3 Nos. 309 211620 927
214.04 18W LED holder 3 Nos. 309 211623 927
214.05 120 W flood light LED 3 Nos. 9,158 211627 27,475
214.06 72 W street light LED 3 Nos. 3,181 211630 9,544
214.07 45 W flameproof light LED 3 Nos. 16,528 212722 49,584
214.08 30 W, 12V light LED for Solar light 3 Nos. 13,848 213596 41,544
215 Supply and installation of 2 X18 W batten lighting fixture of reputed make including LEDs length 04 ft. 6 Nos. 2,812 211635 16,872
216 Supply and Installation of flameproof LED Flood light fixtures 120 W of reputed Make with PESO approved having rating of IP66 or more alongwith removal of old unit. 3 Nos. 10,923 211640 32,769
217 Supply and Installation of LED Type Indication Lamp in Panel. 0
218 Supply and installation of reputed make (L&T,Schneider,Siemens,C&S etc.) switch fuse unit (4 pole) with Top & Bottom Fabricated Enclosure for Cable Entry and removal of existing one. 0
219 Supply and replacement of Capacitors of reputed make 0
220 Supply and Replacement of Heavy duty 4 Pole Terminal block in outdoor lighting JB and in other electrical Panels 0
221 Supply & Replacement of MCB, 10 KA of reputed Make 0
222 Supply & Replacement of MCB/MCCB, 50 KA of reputed make 0
222.08 MCCB Box up to 250A MCCB 6 Nos. 27,013 212605 162,078
223 Supply & Replacement of ELCB/RCCB of reputed make 0
224 Supply and Replacement of HRC Fuse of reputed make 0
225 Supply and Replacement of Bakelite Fuse Fittings of reputed make for below given size 0
226 Supply and Installation of utility spares of reputed make 0
226.01 3 Pin Plug Top up to 16A 15 Nos. 141 208729 2,115
226.02 3 Pin Socket (With/Without Safety Shutter) up to 16A 15 Nos. 108 208730 1,620
226.03 Piano switch up to 16 A (single pole) (Industrial/Modular) 15 Nos. 86 208731 1,290
226.04 Piano switch up to 32 A (double pole) (Industrial/Modular) 15 Nos. 370 208732 5,550
226.05 3 Pin Switch Socket board up to 16 A with indicator (PVC/ Acrylic/Metal) 15 Nos. 380 208733 5,700
226.06 3 Pin 6/16 A surface type combined switch socket outlet (Industrial/Modular) 15 Nos. 174 208734 2,610
226.07 3 Pin 6/16 A flush type socket outlet 15 Nos. 174 208735 2,610
226.08 Switch type fan regulator Electronic 15 Nos. 174 208736 2,610
226.09 Socket type fan regulator Electronic 15 Nos. 261 208737 3,915
226.10 25 mm dia PVC conduit 15 Mtr. 119 208738 1,785
226.11 PVC Casing / Capping of size up to 50 x 16 mm 15 Mtr. 163 209082 2,445
226.12 PVC Flexible Corrugated Conduit up to size 50 mm 15 Mtr. 196 209083 2,940
227 Supply and Installation FLUSH Type On-Off Push Button switch 19mm Dia 15 Nos. 240 500615 3,600
228 Supply and Installation NO/ NC Block for On-Off Push Button Flush Type / STOP push button 15 Nos. 240 500616 3,600
229 Supply and Installation Side Hinged SMC FRP Based Pole mounted Junction Box for Street Light/Flood Lighting pole for below mentioned size of reputed make 0
230 Supply and Installation of Terminal Connectors (Power (Bus-Bar) Terminals Type/Stud Type Terminals/Feed ThroughTerminals) in Melamine Housing, in Electrical Panels & Junction bos suitable to Din Rail type mounting for below mentioned size of reputed make with Side lock plates/separators Operating voltage is 240/440 Volts. 0
230.02 Above 16 SQmm up to-32 Sqmm 3 Nos. 430 500627 1,290
230.03 Above 32 SQm m up to-63 Sqmm 3 Nos. 567 500628 1,701
230.04 Above 63 SQm m up to-120 Sqmm 3 Nos. 0
231 Supply and placing of insulation Rubber Mats (2.5 mm thick, class-B, Colour-Blue) as per IS15652;2006(New IS Standard) & of reputed make. Material batch test certificate shall be provided along with material. 6 Sq. mtr 1,221 211794 7,326
232 Supply and Installation of SS 316, double compression type Cable Glands for armoured twin and multicore power cables of voltage grade 650/1100 V and Instrument cables along with PVC Shrouds. The Glands Shall be Flameproof to Gas Group IIA, IIB and Weatherproof to IP 65, for cables having overall diameters as given below. 0
233 Cable Fault Repairing - Supply and installation of reputed make Cable Jointing Kits for following Cables including IR test and Re-commissioning of cable. The work includes excavation up to the cable, making required trenches for execution of job and backfilling the area. No separate charges shall be paid for manpower, excavation, backfilling, consumables, equipment's, tools & tackles used during execution of this activity. 0
233.01 Upto 3 C x 50 sq. mm. Cu. Armoured Cable 3 Nos. 3,239 208689 9,717
233.02 Upto 4 C x 50 sq. mm. Cu. Armoured Cable 3 Nos. 3,239 208690 9,717
234 Supply and Installation of Cable Jointing Kit for Following Cable reputed make including IR test and Re-commissioning of cable. The work includes excavation up to the cable, making required trenches for execution of job and backfilling the area. No separate charges shall be paid for manpower, excavation, backfilling, consumables, equipment's, tools & tackles used during execution of this activity. 0
234.01 Upto 3.5 C x 120 sq. mm. Al. Armoured Cable 3 Nos. 3,098 208691 9,294
234.02 Upto 4 C x 50 sq. mm. Al. Armoured Cable 3 Nos. 3,098 209099 9,294
235 Supply, Laying & Termination of XLPE insulated, FRLS Outer sheathed, PVC Inner Sheathed Cable Voltage grade 650 / 1100 Volts of following sizes. Above-Ground on cable trays, supported on steel structures, in ready made trenches. The rates shall include the supply and fixing of aluminium number tags, G.I. saddles / clamps, saddle bars, lugs, ferrules, double compression type SS glands, etc, including transportation with all labour and materials as per the specifications, drawings and directions of Engineer-in-charge . The Insulation Resistance of cable has to be checked & report to be submitted before commissioning. No separate charges shall be paid for manpower, consumables, tools & tackles used during execution of this activity. 0
235.01 Upto 2 C x 6 sq. mm. Cu. Armoured Cable 20 Mtr. 308 6,160
235.02 Upto 3 C x 6 sq. mm. Cu. Armoured Cable 20 Mtr. 367 500629 7,340
235.03 Upto 4 C x 6 sq. mm. Cu. Armoured Cable 20 Mtr. 444 500630 8,880
235.04 3 C x 10 sq. mm. Cu. Armoured Cable 20 Mtr. 524 500631 10,480
235.05 4 C x 10 sq. mm. Cu. Armoured Cable 20 Mtr. 619 500632 12,380
235.06 3 C x 16 sq. mm. Cu. Armoured Cable 20 Mtr. 700 500633 14,000
235.07 4 C x 16 sq. mm. Cu. Armoured Cable 20 Mtr. 860 500634 17,200
235.08 3 C x 25 sq. mm. Cu. Armoured Cable 20 Mtr. 1,027 500635 20,540
235.09 4 C x 25 sq. mm. Cu. Armoured Cable 20 Mtr. 1,261 500636 25,220
235.10 1 C x 25 sq. mm. Cu. Armoured Cable 20 Mtr. 650 13,000
235.11 Upto 3.5 C x 50 sq. mm. Al. Armoured Cable 10 Mtr. 528 5,280
235.12 Upto 4 C x 50 sq. mm. Al. Armoured Cable 10 Mtr. 567 5,670
235.13 4C x 70 sq. mm. Al. Armoured Cable 10 Mtr. 673 6,730
235.14 4C x 95 sq. mm. Al. Armoured Cable 10 Mtr. 741 7,410
235.15 4C x 120 sq. mm. Al. Armoured Cable 5 Mtr. 910 4,550
236 Laying & Termination of XLPE insulated, FRLS Outer sheathed, PVC Inner Sheathed Cable Voltage grade 650 / 1100 Volts of following sizes Above-Ground on cable trays, supported on steel structures, in ready made trenches. The rates shall include the supply and fixing of aluminium number tags, G.I. saddles / clamps, saddle bars, lugs, ferrules, double compression type SS glands, etc,. Only Cable will be supplied by GTL at designated stores. The Insulation Resistance of cable has to be checked & report to be submitted before commissioning. No separate charges shall be paid for transportation of cables from GTL designated stores to the site, manpower, consumables, equipment's, tools & tackles used during execution of this activity. Upto 4 C x 125 sq. mm. Cu. Armoured Cable 10 Mtr. 500 5,000
237 Supply, Laying & Termination of PVC insulated, FRLS Outer sheathed, PVC Inner Sheathed instrumentation Cable Voltage grade 650 / 1100 Volts of following sizes Above-Ground on cable trays, supported on steel structures, in ready made trenches. The rates shall include the supply and fixing of aluminium number tags, G.I. saddles / clamps, saddle bars, lugs, ferrules, double compression type SS glands, etc, including transportation with all labour and materials as per the specifications, drawings and directions of Engineer-in-charge . No separate charges shall be paid for manpower, consumables, tools & tackles used during execution of this activity. 0
237.01 FRLS Flexible Earthing cable of 6 sq. mm. 1 Mtr.. 218 212607 218
237.02 Flexible cable up to 3 C x 6 sq. mm. cable 1 Mtr.. 448 3000548 448
238 Supply, Laying & Termination of XLPE insulated, FRLS Outer sheathed, PVC Inner Sheathed Cable Voltage grade 650 / 1100 Volts of following sizes Under-Ground and / or pull through pipes including excavation and backfilling etc. Work includes excavation of trench of average 0.5 meter wide & up to 1.2 meter depth with all appropriate tools & tackles( manual work inside terminals). Layer of sand shall be of 100 mm thick & brick layer shall be laid on cable for protection and back filling of trench after completion of work. work includes carting of surplus earth/debris and handling/unrolling of cable, supply of aluminium tags, lugs, ferrules, double compression type SS glands, etc, including transportation with all labour and materials as per the specifications, drawings and directions of Engineer-in-charge . The Insulation Resistance of cable has to be checked & reported before commissioning. No separate charges shall be paid for excavation, backfilling, manpower, consumables, equipment's, tools & tackles used during execution of this activity 0
238.01 Upto 2 C x 6 sq. mm. Cu. Armoured Cable 1 Mtr. 562 562
238.02 Upto 3 C x 6 sq. mm. Cu. Armoured Cable 1 Mtr. 562 209110 562
238.03 Upto 4 C x 6 sq. mm. Cu. Armoured Cable 1 Mtr. 641 210884 641
238.04 3 C x 10 sq. mm. Cu. Armoured Cable 1 Mtr. 699 209111 699
238.05 4 C x 10 sq. mm. Cu. Armoured Cable 1 Mtr. 794 210885 794
238.06 3 C x 16 sq. mm. Cu. Armoured Cable 1 Mtr. 874 210886 874
238.07 4 C x 16 sq. mm. Cu. Armoured Cable 1 Mtr. 1,034 210887 1,034
238.08 3 C x 25 sq. mm. Cu. Armoured Cable 1 Mtr. 1,179 208697 1,179
238.09 4 C x 25 sq. mm. Cu. Armoured Cable 1 Mtr. 1,413 208698 1,413
238.10 1 C x 25 sq. mm. Cu. Armoured Cable 1 Mtr. 707 210888 707
238.11 Upto 3.5 C x 50 sq. mm. Al. Armoured Cable 1 Mtr. 763 763
238.12 Upto 4 C x 50 sq. mm. Al. Armoured Cable 1 Mtr. 868 868
238.13 4C x 70 sq. mm. Al. Armoured Cable 1 Mtr. 958 958
238.14 4C x 95 sq. mm. Al. Armoured Cable 1 Mtr. 1,128 1,128
238.15 4C x 120 sq. mm. Al. Armoured Cable 1 Mtr. 531 531
239 Laying & Termination of XLPE insulated, FRLS Outer sheathed, PVC Inner Sheathed Cable Voltage grade 650 / 1100 Volts of following sizes Under-Ground and / or pull through pipes including excavation and backfilling etc. Work includes excavation of trench of average 0.5 meter wide & up to 1.2 meter depth with all appropriate tools & tackles( manual work inside terminals). Layer of sand shall be of 100 mm thick & brick layer shall be laid on cable for protection and back filling of trench after completion of work. work includes carting of surplus earth/debris and handling/unrolling of cable, supply of aluminium tags, lugs, ferrules, double compression type SS glands, etc, Cable will be supplied by GTL at designated store. The Insulation Resistance of cable has to be checked & reported before commissioning. No separate charges shall be paid for transportation of cable from GTL designated store to site, excavation, backfilling, manpower, consumables, equipment's, tools & tackles used during execution of this activity. 0
239.01 Upto 3 C x 2.5 sq. mm. Cu. Armoured Cable 1 Mtr. 381 210889 381
239.02 Upto 3 C x 6.0 sq. mm. Cu. Armoured Cable 1 Mtr. 381 210890 381
239.03 Upto 3 C x 10.0 sq. mm. Cu. Armoured Cable 1 Mtr. 381 210891 381
239.04 Upto 3 C x 25 sq. mm. Cu. Armoured Cable 1 Mtr. 406 210892 406
239.05 Upto 4 C x 25 sq. mm. Cu. Armoured Cable 1 Mtr. 406 210893 406
239.06 Upto 3.5 C x 50 sq. mm. Al. Armoured Cable 1 Mtr. 406 406
239.07 Upto 4 C x 50 sq. mm. Al. Armoured Cable 1 Mtr. 406 406
239.08 4C x 70 sq. mm. Al. Armoured Cable 1 Mtr. 406 406
239.09 4C x 95 sq. mm. Al. Armoured Cable 1 Mtr. 406 406
239.10 4 C x 300 sq. mm. Al. Armoured Cable 1 Mtr. 406 406
239.11 4C x 120 sq. mm. Al. Armoured Cable 1 Mtr. 406 406
239.12 3 C x 1 Sq mm Armoured Power Cable 1 Mtr. 295 295
239.13 2 core x 1.5 mm2 Armoured Shield Data cable 1 Mtr. 357 357
240 Supply & Installation of single phase Heavy Duty Exhaust Fan, .No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity. Fan should be having thermal cut off protection. 0
240.03 Size : 600mm, Single Phase, 950 rpm 1 Nos. 9,500 9,500
241 Supply & Installation of single phase Heavy Duty flameproof PESO approved Exhaust Fan, .No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity. Fan should be having thermal cut off protection. 0
242 Supply and Installation of BLDC ceiling fan (reputed make), white / ivory colour, 230v, 1-Phase, 1200 mm sweep. It shall have robust two piece motor construction, All Aluminium alloy construction with double ball bearing and powder coated finish to protect metal from corrosion. The fan shall be energy efficient having 5 star rating. No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity. 3 Nos. 2,500 209128 7,500
243 Supply and Installation of Wall mounted cabin fan , 230V, 1-Phase, 300 mm sweep of reputed make 2 Nos. 3,000 211644 6,000
244 Supply and Installation of self priming Monoblock pumps of reputed make operating on single phase, with matching piping connections. Work includes dismantling of already installed pump, required inlet/outlet connection, foot valves servicing & cable termination. No separate charges shall be paid for manpower, consumables,equipments, tools & tackles used during execution of this activity. Upto 2.0 HP 2 Nos. 15,000 30,000
245 Rewinding of the following motors/Monoblock Pump. work includes removal of the equipment, rewinding & repairing, re-installation of the same.(Including replacement of Bearing).No separate charges shall be paid for manpower, consumables,equipments, bearings, tools & tackles used during execution of this activity. 0
245.01 Ceiling or wall mounted fan 3 Nos. 872 208726 2,616
245.02 Monoblock pump up to 2.0 HP 3 Nos. 2,452 3000554 7,356
245.03 Exhaust Fan heavy duty 3 Nos. 1,634 208727 4,902
245.04 Exhaust Fan heavy duty explosion proof IIA & IIB 3 Nos. 2,398 210928 7,194
246 Supply & Replacemet of condensor coil for 1.5 TR AC 0
247 Supply and installation of capacitor for A.C compressor of 1.5 TON, 2 TON 0
248 Supply and installation of capacitor for fan motor of 1.5 TR, 2 TR of AC Unit 0
249 Supply and installation of thermostat switch of compressor for AC 1.5 TR, 2 TR 1 Nos. 864 210032 864
250 Supply and replacing of faulty relay in compressor for AC 1.5 TR, 2 TR 1 Nos. 756 210033 756
251 Supply and replacement of 3 way switch for AC 1.5 TR, 2 TR 1 Nos. 702 210034 702
252 Supply and replacing of outer cover for AC units for 1.5 TR, 2 TR 0
253 Supply and replacing of front grill of Split A.C of 1.5 TR, 2 TR 0
254 Supply and installation of copper tubing for AC 1.5 TR, 2 TR 1 Mtr. 1,199 213210 1,199
255 Supply and replacing of contactor coil for AC 1.5 TR, 2 TR 0
256 Repairing of control circuit of indoor AC unit up to 02 Ton 1 Nos. 3,450 210760 3,450
257 Supply and installation of control circuit unit from OEM of indoor AC unit up to 02 Ton 1 Nos. 5,838 213116 5,838
258 Supply and installation of required Cu armoured cable for AC of 1.5 TR, 2TR 1 Mtr. 424 212699 424
259 Supply and replacing of Drain pipe of PVC for AC 1.5 TR, 2 TR 1 Mtr. 159 212960 159
260 Supply and replacing of Swing motor 12 V for AC 1.5 TR, 2 TR 0
261 Supply and replacing of exhaust fan of outdoor unit for AC 1.5 TR, 2 TR 0
262 Supply and replacing of flapper for indoor unit for AC 1.5 TR, 2 TR 0
263 Supply and replacing of Air filter net for AC 1.5 TR, 2 TR 0
264 Supply and replacing of insulation of AC duct from outdoor to indoor for 1.5 TR, 2 TR 1 Mtr. 380 213211 380
265 Repairing, rewinding & re-installation of blower fan motor for 1.5 TR, 2 TR AC.This job includes removal of faulty motor, repairing & rewinding and re-installation. No separate charges shall be paid for manpower, consumables, bearings, equipment's, tools & tackles used during execution of this activity. 1 Nos. 1,307 210048 1,307
266 Supply and replacing of insulation of indoor blower fan motor for 1.5 TR, 2 TR AC 1 Nos. 2,715 212610 2,715
267 Supply and replacing of AC outdoor unit valve brass cap for 1.5 TR, 2 TR 1 Nos. 558 212612 558
268 Charging of refrigerant for 1.5 TR, 2 TR AC 1 Nos. 2,180 210049 2,180
269 Supply and repalcing of fan blade assembly of 1.5 TR AC 0
270 Supply and replacement of motor assembly of indoor unit for 1.5 TR AC 0
271 Shifting of A.C including gas charging, up to three meter copper tubing and civil work for 1.5 TR, 2 TR. The job includes dismantling, handling, transportation, re-installation, testing & commissioning of A.C.Units. No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity. Above three meter copper tubing will be paid extra as per relevant SOR. 1 Nos. 3,814 210055 3,814
272 Supply and installation of the outdoor unit condenser body of AC 1.5 to 2 TR. The job includes dismantling of old one,re-installation of new one , testing & commissioning. No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity. 1 Nos. 4,904 210056 4,904
273 Supply of compressor and installation including gas charging for 1.5 & 2 TR Split AC(including inverter AC) . No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity. 1 Nos. 13,624 209195 13,624
274 Repairing & Reinstallation of AC Timer Panel, including replacement of Timer PCB & Relays. 1 Nos. 1,906 210919 1,906
275 Supply & installation of AC Timer Panel of Microprocessor based for Max 6 no of A.C Timer Operation. 1 Nos. 3,814 209199 3,814
276 Supply & Installation of Faulty PCB after repairing of Indoor AC unit for 1.5 TR to 2.0 TR 1 Nos. 3,814 209200 3,814
277 Repairing of Indoor PCB of Inverter AC unit up to 02 Ton 2 Nos. 3,000 6,000
278 Repairing of Outdoor PCB of Inverter AC unit up to 02 Ton 2 Nos. 3,000 6,000
279 Supply and installation of Indoor PCB unit from OEM of Inverter AC unit up to 02 Ton 1 Nos. 5,000 5,000
280 Supply and installation of Outdoor PCB unit from OEM of Inverter AC unit up to 02 Ton 1 Nos. 5,000 5,000
281 Supply and replacement of Capillary of AC Unit upto 2 TON. Job includes gas charging. 1 Nos. 1,000 1,000
282 Supply & Installation of Air Conditioner out door unit Bracket/Stand. The Job includes of installation of required bracket in wall with drill & suitable fasteners. 1 Nos. 1,634 210920 1,634
283 Supply and installation of Banjo hose for DG set up to 125 KVA 1 Nos. 514 211656 514
284 Supply and Installation of KWH meters in DG set 1 Nos. 1,849 211655 1,849
285 Supply and installation of Thermostat for DG set up to 125 KVA 1 Nos. 1,849 211654 1,849
286 Supply and installation of Water temperature switch for DG set up to 125 KVA 1 Nos. 924 211653 924
287 Supply and installation of Spin on Lube oil Filter for DG set up to 125 KVA 1 Nos. 872 211652 872
288 Supply and installation of Spin on Diesel Filter for DG set up to 125 KVA 1 Nos. 1,489 211651 1,489
289 Supply and installation of Battery Charger 12 V for DG set up to 125 KVA 1 Nos. 4,623 211650 4,623
290 Supply and installation of Magnetic Pick-up coil for DG set up to 125 KVA 1 Nos. 4,623 211649 4,623
291 Supply and Installation of DG Set Exhaust pipe Insulation (Rope) Coating 2 R. Mtr. 358 716
292 Supply of Coolant for coolant cooled engines 1 Litres 266 211633 266
293 Repairing of the leaked Radiator of Diesel Generator Set for the Capacity. includes dismantling and installation. Upto 125 KVA 1 Nos. 3852 500651 3,852
294 Supply & replacement of Automatic Voltage Regulator of Cummins make D.G set. No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity. 1 Nos. 11,816 209206 11,816
295 Supply and Installation of Fuel Filter PRE Type 1 Nos. 667 209207 667
296 Supply of Fuel Filter MIC Type 1 Nos. 667 209208 667
297 Supply of Lube Oil Filter Element 1 Nos. 718 209209 718
298 Supply of Air Filter 1 Nos. 2,542 209210 2,542
299 Supply of Air Cleaner 1 Litres 2,542 211625 2,542
300 Supply & replacement of "V"-Belt for blower/dynamo of Kirloskar/Cummins/ Crompton Greaves/ A49 make. No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity. 1 Nos. 667 209212 667
301 Supply & replacement of Bearing set. No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity. 1 Nos. 2,569 209215 2,569
302 Supply & replacement of Oil seal for crank. No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity. 1 Nos. 2,773 209216 2,773
303 Supply & replacement of Steel Braided Diesel Pipe with/without banjo connection. No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity. 1 Mtr. 308 212961 308
304 Servicing of Alternator of below mentioned rating DG sets, the job includes removal of oil and dirt accumulation, greasy deposits on the windings should be wiped off with a lint free cloth dipped in petroleum solvent such as kerosene, petroleum spirit to avoid short circuit. To check the condition of magnetic rotors & bearings, no-load and full-load test etc. No separate charges shall be paid for manpower, consumables, equipments, tools & tackles used during execution of this activity. 0
305 Supply & installation of floating mechanical fuel gauge on fuel tank of Kirloskar/Cummins/ Crompton Greaves Make 1 Nos. 1,961 1,961
306 Repair of 12 V DG battery charger 1 Nos. 2,942 2,942
307 Supply & replacement of "O" ring set of Kirloskar/Cummins/ Crompton Greaves make. No separate charges shall be paid for manpower, consumables, equipments, tools & tackles used during execution of this activity. 1 Nos. 1,026 1,026
308 Repairing / replacement of Display of control card of Kirloskar/Cummins/ Crompton Greaves Make 1 Nos. 4,739 4,739
309 Supply and installation of Hot insulation with GI cladding by filling glass wool as per EIC requirement. 1 Sq. Mtr. 1,743 1,743
310 Dismantling of exisitng battery & re-installation of the same after charging (for battery of DG, Inverter, Solar etc.) 1 Nos. 1,643 1,643
311 Supply and replacement of engine oil for DG set / (20W40/15W40) 1 Litres 328 209218 328
312 Supply and Replacement of Cooling water pump for DG set up to 125 KVA 1 Nos. 8,000 213524 8,000
313 Supply and installation of DG set safety unit. 8 Nos. 3,649 29,192
314 Supply and installation of DG set Frequency meter. 6 Nos. 782 4,692
315 Supply and installation of DG set Oil temperature gauge. 6 Nos. 473 2,838
316 Supply and installation of DG set emergency start/stop switch. 22 Nos. 473 10,406
317 Supply and installation of DG set hour meter. 11 Nos. 5,876 64,636
318 Supply and installation of DG set 12V 35 Amp battery charger alternator. 8 Nos. 4,739 37,912
319 Supply and installation of DG set diesel tank cover/cap. 21 Nos. 758 15,918
320 Supply and installation of DG set controller unit. 12 Nos. 1,943 23,316
321 Supply and Service of Low Pressure Oil switch for DG set from OEM 9 Nos. 1,895 17,055
322 Supply and Service of High Temperature safety unit for DG set from OEM 6 Nos. 3,649 21,894
323 Servicing/refurbishment of Fuel Injector Pump of Kirloskar/cummins/Cooper/Crompton/Mahindra make DG Sets. The job includes removal & re-installation of the same after servicing. No separate charges shall be paid for manpower, consumables, equipments, tools & tackles used during execution of this activity. 1 Nos. 30,000 30,000
324 Supply & Installation of Automatic Float-Boost charger of 12V 6 Amp Rating. No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity. 1 Nos. 5,651 209221 5,651
325 Supply, removal of old battery & Installation of new 12V Lead-Acid Battery of Approved make for Invertor/ DG Set. No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles, used during execution of this activity. Contractor shall quote considering the buyback of old battery. 0
326 Supply & Installation of 12V SMF Battery of Approved make. No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity. Contractor shall buyback the old battery, hence price shall be quoted accordingly. 0
327 Servicing of DG starter system. The Work involves checking of ignition start switch & magnetic switch, fuse between ignition switch and 12 V battery, 12 V battery voltage and Sp. Gravity of battery water. Top-up of DM water in battery if required. 0
327.01 Supply and replacement of bearings. 1 Nos. 1,849 209233 1,849
327.02 Supply and replacement of magnetic rotors. 1 Nos. 4,623 209234 4,623
327.03 Rewinding of Alternator up to 50 kVA . 1 Nos. 35,447 209235 35,447
327.04 Rewinding of Alternator above 50 kv to 125 KVA 1 Nos. 42,125 210924 42,125
328 Servicing of DG starter system. The Work involves checking of ignition start switch & magnetic switch, fuse between ignition switch and 12 V battery, 12 V battery voltage and Sp. Gravity of battery water. Top-up of DM water in battery if required. 0
328.01 Rewinding of Stator upto 50 kVA . 1 Nos. 10,000 10,000
328.02 Rewinding of Stator above 50 kVA to 125 KVA 1 Nos. 15,000 15,000
328.03 Rewinding of Field Stator upto 50 kVA . 1 Nos. 10,000 10,000
328.04 Rewinding of Field Stator above 50 kVA to 125 KVA 1 Nos. 15,000 15,000
328.05 Rewinding of Field Rotor upto 50 kVA . 1 Nos. 10,000 10,000
328.06 Rewinding of Field Rotor above 50 kVA to 125 KVA 1 Nos. 15,000 15,000
329 Supply and installation of Power contactors 4 pole up to 200A 1 Nos. 15,664 213525 15,664
330 Supply & Replacement of Faulty Power Contactor coil (65A-200 A;UI=1000V) 1 Nos. 18,494 209238 18,494
331 Supply & Replacement of Faulty Aux Contactor coil (For R,Y,B Phase Indication Contactor, 240 V Rating) 1 Nos. 1,130 209239 1,130
332 Supply & Replacement of Faulty Aux Contactor (For R,Y,B Phase Indication, 4A, 415/440 V Rating) 1 Nos. 1,849 209240 1,849
333 Supply and replacement of Current Transformer 0
333.01 CT Rasin Cast : CT ratio 50-100/1-5A, CL 5P20, VA 7.5 1 Nos. 945 209241 945
333.02 CT Rasin Cast : CT ratio 50- 100/1-5A, CL 1, VA 7.5 1 Nos. 1,007 209242 1,007
334 Supply and replacement of Analog/Digital Ammeters (0-100 Amp/AC/DC) 1 Nos. 1,386 209252 1,386
335 Supply and replacement of Analog/Digital Voltmeters (0-450 V AC/DC) 1 Nos. 1,386 209257 1,386
336 Supply and replacement of SF6 cylinder in case of SF6 breaker. 1 Nos. 1,541 209266 1,541
337 Dismantling, powder coating (Alkali Resistant Epoxy Powder Coated , Shade:RAL 7032) & reassembling of Ni-CD Battery Rack. Work includes Surface Cleaning of batteries with DM water & potential measurement of each cell voltage after reassembling. No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity. 1 Nos. 6,678 209270 6,678
338 Supply of solenoid valve 1 Nos. 8,175 500669 8,175
339 Supply and replacement of display with Control card /circuit 1 Nos. 2,670 501459 2,670
340 Supply and replacement of ignition key assembly. 1 Nos. 3,269 500673 3,269
341 Supply and installation of door hinges and locks for DG set canopy 1 Nos. 1,634 500674 1,634
342 Supply and installation of caution board/danger notice on electrical panel as per IS 2551 having skull and bone sign with voltage level. 1 Nos. 925 500677 925
343 Supply & Installation of Terminal plate of 9 terminals with copper links for different type of TLP units 1 Nos. 4,682 213526 4,682
344 Supply and replacement of solar light Solar Spares Job includes installation on pole (upto 6 mtr height) including SS nut bolts, termination, removal of old fixture etc. No separate charges shall be paid for manpower, consumables,lifting equipments, handling, tools & tackles used during execution of this activity. 0
344.01 Supply and installation of Solar Module (Vikram Solar, Waree Solar,Goldi green technologies pvt ltd, Tata power solar systems pvt.ltd, Solar systmes pvt.ltd, Moser bear solar limited, XL energy limited, Solar semiconductor, Emmvee photovoltaics pvt ltd ,Navitas green solutions pvt ltd, Satvik, Panchwakr solar, Surana solar) 8 Nos. 16,350 211684 130,800
344.02 Supply and installation of Photovoltaic Battery 12V 150AH ( Exide, Okaya, Luminous, Relicell, Artheon, Su-kam, base, Southern, HBL, Gem)Contractor Shall teken the old Battery 9 Nos. 16,894 152,046
344.03 Supply and replacement of Charge Controller (Systeller, Flin energy, SuKam, UTL Inverter, Luminous/Equivalent make) 9 Nos. 21,254 191,286
344.04 LED Street light Fixtures Solar Lighting Poles (Philips, Crompton, Wipro, Havells, Oreva, Charlson, Syska, Moser bear, Surya, Bajaj) 2 0 0
344.05 LED Luminarie Fixture 09 -12 Watts 8 Nos. 2,167 17,336
344.06 LED Luminarie Fixture 18 - 24 Watts 8 Nos. 2,422 19,376
344.07 LED Luminarie Fixture 30 - 43 Watts 8 Nos. 2,881 23,048
344.08 Approved make PCB for LED Luminarie Fixture 09 -12 Watts 8 Nos. 2,932 23,456
344.09 Approved make PCB for LED Luminarie Fixture 18 - 24 Watts 8 Nos. 3,973 31,784
344.10 Approved make PCB for LED Luminarie Fixture 30 - 43 Watts 8 Nos. 7,226 57,808
344.11 Approved make 12 Volt SMPS for LED Luminarie Fixture 09 -12 Watts 8 Nos. 1,307 10,456
344.12 Approved make 12 Volt SMPS for LED Luminarie Fixture 18 - 24 Watts 8 Nos. 1,634 13,072
344.13 Approved make 12 Volt SMPS for LED Luminarie Fixture 30 - 43 Watts 8 Nos. 2,180 17,440
344.14 Poweder Coated Battery Box 17 Nos. 1,961 33,337
344.15 Supply, Laying & Terminaltion of 2C x 4 Sq. mm armored power cable 17 R. Mtr. 174 2,958
345 Supply & Installation (Including removal of existing one) of Ni-CD Battery (NCPP/ VRPP) 1.2 V for UPS system 0
345.03 HVM 1.2 Volt, 170AH Nos. 0
346 Supply and Installation of Pre cast Cable Route Marker (For Instrumentation and Electrical cables) 1 Nos. 770 211705 770
347 Dismantling and stacking of damaged lighting pole including excavation, cutting etc.& backfilling if required, completion of job in totality to the satisfaction of EIC within a lead of 100Mtr. The safe removal of existing luminaire, JBs, Earthing connection, cable connection etc. from the pole and handing over of same to GTL is in contractor's scope. No separate charges shall be paid for manpower, consumables, lifting equipment's, handling, tools & tackles used during execution of this activity. 1 Nos. 4,074 210976 4,074
348 Relocation of Lighting / Solar/OPD/PGD pole within the terminal which includes removal with or without RCC foundation & re-installation with proper foundation, concrete support etc. complete in all respect. This also includes levelling of old foundation location & backfilling if required, with all tools/tackles/labour/machinery/Hydra etc. Removal of fixtures, JB, earthing connections, Cable connections from pole at old location & reconnection and testing of all the system at new location is included in the scope. In case of relocation of pole to other terminal the transportation shall be given as per the relevant SOR. 1 Nos. 5,897 210066 5,897
349 TR Unit Fault finding, Breakdown maintenance irrespective of number of visits by Expert or representative of OEM of TR Unit and Repaired / replacement of spares if any required . The rates for Spares to be paid separately as per relevant SOR 1 Per TR 12,282 211987 12,282
350 Supply and installation of Corrosion Coupons including necessary excavation, backfilling ,cable joint etc. excluding cost of cable 1 No 8,549 211988 8,549
351 Current Attenuation Test survey at every 100 mtr. On pipeline network and submit complete detail report along with graph and recommendations. 1 Kms 5,592 211989 5,592
352 Health Assessment of Transformer Rectifier unit once in year through OEM for verify the efficiency of TR unit 1 Unit/Location 5,449 212055 5,449
353 Foreign Pipeline crossing survey for proper bonding and interference 1 Per location 1,421 212647 1,421
354 Interference Survey (AC / DC / Stay current) for Main line with 24 Hrs. data logging 1 per location 6,540 212062 6,540
355 CIPL Survey 1 Per KM 5,995 212064 5,995
356 DC interference survey for SV/IP /Terminal stations, critical area of interference, reasons & mitigation recommendations 1 Per location 8,283 212065 8,283
357 Direct Current Voltage Gradient (DCVG) based on CIPL / CAT survey report and recommendations and submit complete detail report along with fault location drawing and recommendations. 1 Kms 7,051 211990 7,051
358 Alternate Current Voltage Gradient (ACVG) based on CIPL / CAT survey report and recommendations and submit complete detail report along with fault location drawing and recommendations. 1 kms 7,051 7,051
359 Painting of TLP/AJB/CJB unit including numbering and letter stencilling of TLP type by supply of reputed brand epoxy based Anti Corrosive Paint and Primer of zinc chromate base, including cleaning by wire brushing, scrapping the rusted area and application of Primer (2 coat) & Finish paints (2 coat) of TLP with labour, materials, transportation. 300 No 910 211991 273,000
360 Supply and Installation of new TLP (A/B/C/D/E/I) with bend as per the drawing attached, along with diagram plate including necessary civil Foundation, excavation, backfilling,cable joint, stenceiling etc. excluding cost of cable 30 No 16,726 211992 501,780
361 Supply and Installation of new TLP Type H with bend as per the drawing attached, along with diagram plate, including necessary civil Foundation, excavation, backfilling ,cable joint, stenceiling etc. excluding cost of cable 30 No 21,069 211993 632,070
362 Supply and Installation of new FRP TLP (A/B/C/D/E/I) with bend as per the drawing attached, along with diagram plate including necessary civil Foundation, excavation, backfilling etc excluding cost of cable 22 Nos. 12,000 264,000
363 Supply and Installation of new AJB with bend as per the drawing attached, along with diagram plate including necessary civil Foundation, excavation, backfilling Cable joint, stenceiling etc. excluding cost of cable. 1 No 24,310 211994 24,310
364 Installation of new TLP along with necessary civil Foundation, excavation, backfilling cable joint, stenceiling etc.but excluding cost of cable. 1 No 3,093 211995 3,093
365 Supply and installation of TLP/AJB/CJB doors along with necessary welding, hinges, allen bolts etc. Old damaged doors shall be handed over to GTL, if any 1 No 2,653 211996 2,653
366 Cable to Pipe Joints by using Pin Brazing method. (Thermit weld not allowed) . This job includes necessary excavation, removal of coating, restoration of coating by Araldite Hardener and backfilling and restoring to original condition as per direction of EIC. Rate of cable supply shall be given as per relevant SOR mentioned elsewhere. Holiday Detection shall be done post restoration of coating. 1 No 5,176 211997 5,176
367 Re-installation of TLP after shifting the existing TLP from its present location to a new location for better approachability including necessary cable laying & jointing but excluding Cable to Pipe connection. necessary civil Foundation, excavation, backfilling etc. included in the scope of work. but excluding cost of cable. Rate of cable supply shall be given as per relevant SOR mentioned elsewhere 1 No 3,541 211998 3,541
368 Supply & Replacement of Mother Board in TR unit 1 No 17,493 212000 17,493
369 Supply & Replacement of Display Board in TR unit 1 No 10,881 212001 10,881
370 Supply & Replacement of Control Card in TR Unit (Card No-CECO 103A, KS103B, CECO 104C1,KS104C, CECO 105D1, KS 105D1DC, CECO 106, KS106, CECO 118B, KS 107-R2 etc.) 5 No 7,084 212002 35,420
371 Supply & Replacement of Filter circuit, which consist of Capacitor series (3 or 4 Nos) as per TR unit specification & existing Capacitor rating. 1 Set 2,725 212003 2,725
372 Supply & Installation of Analogue Panel Meter, Size 96 X 96, 230 Volt Operated (AC-Ameter,AC- Voltmeter) 5 No 1,961 212004 9,805
373 Supply & Installation of Digital Volt Meter, Size 48 X 96, Aux Supply:- 230 Volts AC operated, 5 No 1,961 212005 9,805
374 Supply & Installation of Digital Ammeter, Size 48 X 96, Aux Supply:- 230 Volts AC operated or 5 Volts DC operated, Range : 0-1 A, Display : 0-10 A 5 No 1,961 212006 9,805
375 Supply & Installation of Digital Voltmeter, Size 48 X 96, Aux Supply:- 230 Volts AC operated or 5 Volts DC operated , Range : 0-20 VDC, Display : 0-20 VDC 5 No 1,961 213212 9,805
376 Supply & Installation of Digital Voltmeter, Size 48 X 96, Aux Supply:- 230 Volts AC operated or 5 Volts DC operated, Range : 0-30 VDC, Display : 0-30 VDC 5 No 1,961 213213 9,805
377 Supply & Installation of Digital Voltmeter, Size 48 X 96, Aux Supply:-5 Volts DC operated, Range : 0-200 VDC, Display : 0-200 VDC 5 No 1,961 213214 9,805
378 Supply & Installation of Digital Ammeter, Size 48 X 96, Aux Supply:- 230 Volts AC operated or 5 Volts DC operated, Range : 0-75 mV, Display : 0-30 A 5 No 1,961 212010 9,805
379 Supply & Installation of 4 - Position Rotary Switch used for Reference Electrode Selection. 5 No 1,361 212011 6,805
380 Supply & Installation of 8 - Position Rotary Switch used for Reference Voltmeter Selection 5 No 1,493 212012 7,465
381 Supply & Installation of 6 - Position Rotary Switch used for Reference Voltmeter Selection 5 No 1,493 212013 7,465
382 Supply installation, Testing and commissioning of Signal Transducer (Converter) for PSP, Aux Supply:-230 Volts AC operated or 48 Volts DC operated, Input:-0-4 VDC, Output:-4-20 mADC. 13 No 5,995 212014 77,935
383 Supply, installation, Testing and commissioning of Signal Transducer (Converter) for DCV, Aux Supply:-230 Volts AC operated or 48 Volts DC operated, Input:-0-60 VDC, Output:-4-20 mADC. 13 No 5,995 212015 77,935
384 Supply, installation, Testing and commissioning of Signal Transducer (Converter) for DCA, Aux Supply:-230 Volts AC operated or 48 Volts DC operated, Input:-0-75 mVDC, Output:-4-20 mADC. 13 No 5,995 212016 77,935
385 Supply and installation, Testing and commissioning of Kirk cell with enclosure (Rated capacity 5KA ) 10 No 46,324 212017 463,240
386 Supply and Installation, Testing and commissioning of 21 Kgs of 99.99% pure Zinc grounding anodes with necessary backfill material with required excavation and backfilling, termination etc. 35 No 23,053 212018 806,855
387 Maintenance of Kirk Cell along with supply of 30% pure KOH solution and a thin oil film along with replacement of of Kirk cell casing box (enclosure) if broken and cleaning of steel plates of Kirk cell. 45 No 3,161 212019 142,245
388 Re-installation of Zinc Grounding anode which includes necessary excavation, cleaning of zinc anodes, and supply of backfill material along with necessary cotton bags. Additional required cable shall be claimed as per relevant SOR mentioned elsewhere 2 No 4,087 212020 8,174
389 Supply and installation of a set of resistors and shunts for AJB of various ratings as per instruction of EIC. 1 No 2,015 212022 2,015
390 Excavation of Anode Ground Bed in depth of one meter after providing and laying common salt of approx. 500 kgs and sufficient watering of ground bed. The job includes cost of salt, watering, excavation / backfilling charges etc. After completion of above job, circuit resistance is to be measured and recorded as per instruction of EIC 1 No 11,893 212023 11,893
391 Supply, installation, testing and commissioning of considered High Silicon Cast Iron oxide anode of 21 Kgs weight and with canister, anode cable, metallurgical grade coke breed, auguring of appropriate size of hole , anode to cable joint and necessary termination as per standard practice and satisfaction of EIC 1 No 22,493 212220 22,493
392 Supply, installation, testing and commissioning of considered MMO type anode of appropriate weight and with canister, anode cable, metallurgical grade coke breed, auguring of appropriate size of hole , anode to cable joint and necessary termination as per standard practice and satisfaction of EIC.inclusive of removal of exinsting anode if any. Rating for MMO type Anode: 1) Anode Shape and Dimensions: 750mm+/- 5mm Long 25.4 mm OD + 0.40/ -0.79 mm 1mm +/-0.1mm thick 2) Anode weight (without cable) 0.210 Kg/m +/- 0.021 Kg/m 1 No 35,755 212024 35,755
393 Supply & Installation of permanent reference Cell (Cu-CuSO4) with 30 mtr tail cable (Make: MC Miller USA or HARCO USA) with a warranty of minimum 2 years from date of installation at existing or new location of pipeline, including excavation, backfilling with required backfilling compound, supply and installation of 2" PVC pipe for watering,supply & installation of tag plate and connection complete in all respect as per instruction of EIC. Additional cable if any required shall be claimed as per relevant SOR mentioned elsewhere. 1 No 21,271 212026 21,271
394 Supply & Installation of permanent reference Cell (Zinc) with 30 mtr tail cable (Make: MC Miller USA or HARCO USA) with a warranty of minimun 2 years from date of installation at existing or new location of pipeline, including excavation, backfilling with required backfilling compound, supply and installation of 1" 2" PVC pipe for watering, supply & installation of tag plate and connection complete in all respect as per instruction of EIC. Additional cable if any required shall be claimed as per relevant SOR mentioned elsewhere. 1 No 21,271 21,271
395 Supply & Installation, Testing & commissioning 10 Kg of magnesium anode with required cable length, excavation & backfilling of soil complete as per standard specification & EIC instructions 1 No 13,881 212028 13,881
396 Removals of corrosion coupon by excavation, sending it to the lab for analysis, submit the report with analysis and recommendations. The area should be backfilled after removal of CC. The work includes all labour cost and laboratory analysis cost. 1 No. 14,151 212029 14,151
397 Supply, Laying & Termination (using lugs, ferrules & double compression type FLP glands) of FRLS Cable Under-Ground including Excavation & Backfilling etc. (At depth of 0.7 to 1.2 mtrs, sand packing of 250 mm and brick covering) with supply of sand & bricks including termination of cable at both ends with supply of appropriate size of glands, lugs etc.and cable jointing. Work includes excavation of trench of average 0.5 meter wide & up to 1.2 meter depth with all appropriate tools & tackles( manual work inside terminals). Layer of sand shall be of 100 mm thick & brick layer shall be laid on cable for protection and back filling of trench after completion of work. work includes carting of surplus earth/debris and handling/unrolling of cable etc. 0
397.01 1C x 6mm2 armoured copper cable with PVC insulation and FRLS Characteristics 630 Mtr 245 212030 154,350
397.02 1C x 4mm2 armoured copper cable with PVC insulation and FRLS Characteristics 200 Mtr 234 212031 46,800
397.03 1C x 10mm2 armoured copper cable with PVC insulation and FRLS Characteristics 130 Mtr 322 212032 41,860
397.04 1C x 25mm2 armoured copper cable with PVC insulation and FRLS Characteristics 500 Mtr 469 212033 234,500
397.05 1C x 16mm2 armoured copper cable with PVC insulation and FRLS Characteristics 50 Mtr 469 23,450
397.06 1C x 35mm2 armoured copper cable with PVC insulation and FRLS Characteristics 10 Mtr 716 7,160
398 Supply & Installation, Testing & commissioning of Solid state electronic polarization cell of 5KVA including supply and installation of mounting stand/plate, as per GTL approved vendor. 17 No 148,033 212035 2,516,561
399 Supply & Installation, Testing & commissioning of Solid state electronic polarization cell of 25KVA including supply and installation of mounting stand/plate,as per GTL approved vendor. 3 No 185,000 555,000
400 Supply & Installation, Testing & commissioning of Surge diverter -20KVA / 8-20 µ sec 13 No 17,870 212036 232,310
401 Supply & Installation, Testing & commissioning of Pre packed zinc grounding cell 12.5 kg wt X 2 nos with 6Mtr. -25 sqmm cu, PVC unarmoured tail cable prepacked in chemical backfill with required backfilling, excavation and termination etc as per instruction of EIC 17 No 27,206 212037 462,502
402 Supply of Portable reference electrode Cu-CuSo4 (MC Miller USA or HARCO USA makes) with a warranty of minimum 1 years from date of supply. 4 No 12,265 212038 49,060
403 Supply & Installation, Testing & commissioning of Electrical Resistance Probe as per GTL approved vendor. 14 No 71,980 212042 1,007,720
404 Supply, laying & commissioning of Zinc Ribbon for AC interreference grounding as out come of AC interference survey report work includes excavation and backfilling with mixture Gypsum bentonite & SodiumSulfate. 170 Per KG 1,560 212044 265,200
405 Supply, Installation, Testing and Commissioning of Polarization Coupon along with permanent reference cell (Cu-CuSO4 ref cell),1x10 sq mm Copper conductor XLPE insulated PVC sheathed armoured cable, Magnetic Reed Switch, 1x6 sq mm Copper conductor XLPE insulated PVC sheathed armoured cable for potential measurement 1 No 29,500 29,500
406 Laying & Termination/Cable Jointing of CP cable, which includes excavation & back filling. Additional SOR to be operated for CP Cable 5 Mtr. 294 212045 1,470
407 Laying and termination of CP cable for Insulating Joint for available clit on IJ. No need for Pin Brazing. All consumable like Funnel, M-Seal, Epoxy & Hardener etc in the scope of contractor. 5 Per Mtr 315 212047 1,575
408 Soil Resistivity Survey 1 Per KM 2,449 2,449
409 Supply and installation of LED lighting luminaire with LED & driver complete. Job includes installation on wall/ceiling, termination, removal of old fixture etc. No separate charges shall be paid for manpower, consumables,lifting equipments, handling, tools & tackles used during execution of this activity. 0
410 Supply and Installation of 2*18W flameproof LED tube light suitable for battery room 5 Nos. 2,858 213033 14,290
411 Supply & Installation of following rating Integrated Solar Street light 30W consists of a Solar panel and LED luminary with built-in Lithium-ion / Lithium Ferro Phosphate battery (LiFePO4) battery of appropriate Ah Capacity and solar driver card with charge controller. In addition, LED luminary has a motion sensor to increase / decrease the LED light brightness on detecting any movement near the solar light. of standard make. with 2 years product warranty & Battery warranty 5 year. Also needs Designed for outdoor use. Completely waterproof (IP65 rating) design. Installation of this fixture to be done on existing Solar lighting pole (retrofit type) 3 Nos. 13,848 211634 41,544
412 Supply & Installation of following rating Semi-Integrated Solar Street light of 30 W consists of a Solar panel and LED luminary with built-in Lithium-ion / Lithium Ferro Phosphate battery (LiFePO4) battery of appropriate Ah Capacity and solar driver card with charge controller. In addition, LED luminary has a motion sensor to increase / decrease the LED light brightness on detecting any movement near the solar light. of standard make. with 2 years product warranty & Battery warranty 5 year. Also needs Designed for outdoor use. Completely waterproof (IP65 rating) design. Installation of this fixture to be done on existing Solar lighting pole (retrofit type) 15 Nos. 13,195 213527 197,929
413 Repairing & re-installation of following rating Integrated Solar Street light of 30W fixtures which is consists of a Solar panel and LED luminary with built-in Lithium-ion / Lithium Ferro Phosphate battery (LiFePO4) battery and solar driver card with charge controlled and motion sensor. The Job shall includes replacement of faulty LED, PV Module, Motion sensors, LION Battery etc as per requirement. 6 Nos. 6,701 3000587 40,206
414 Supply and Installation of following size Four Way/Multiway Flameproof Junction box of Approved Make as per the GTL Vendor list attached with this tender. Suitable for Gas Group IIA, IIB, Ex d type, CMRI Approved ZONE-1 & ZONE-2. IP-65/66, T6 Class. Unused Cable entry shall be sealed with appropriate FLP plug 0
414.01 Ex d IIA/IIB 4 Way Junction box 100 Dia. 1 Nos. 5,807 212693 5,807
414.02 Ex d IIA/IIB Multi Way Junction box 170 Dia. 1 Nos. 7,594 212694 7,594
414.03 Ex d IIA/IIB Multi Way Junction box 260 Dia. 1 Nos. 11,167 212695 11,167
414.04 Ex d IIA/IIB Multi Way Junction box 340 Dia. 1 Nos. 16,528 212696 16,528
414.05 Ex d IIA/IIB Multi Way Junction box 700 X 700 mm 1 Nos. 31,270 212697 31,270
414.06 Supply of Swing Pedestal fan, 230V, 1-Phase, 400 mm sweep. 1 Nos. 4,020 212704 4,020
415 Supply and Installation of Exhaust Fan Louvers 0
416 Supply & installation of Lighting Arrester as per latest relevant IS/IEC Code. All tools/tackles/manpower/material/transportation in the scope of contractor 1 Nos. 7,108 212945 7,108
417 Supply & Installation Electrical panel lock 10 Nos. 200 213528 2,000
418 Supply and installation of UV laminated and rewritable earth pit tag plate of 4 mm ACP sheet of size (10" x 8"), along with 20 mm dia pipe of 750 mm length with necessary civil work. Tag should mentioned pit no., resistance, test date and due date. 10 Nos. 50 213529 500
419 Off potential measurement 0
419.01 24" x 101.420 km ARPL-Section B (Total no of TLP 123 NOS) 1 LS 61500 61,500
419.02 18"x 67.802 kmMorbi SPUR LINE (Total no of TLP 88 NOS) 1 LS 44000 44,000
419.03 30" x 109.172 km Rajkot Jamnagar Pipeline (Total no of TLP 132 NOS) 1 LS 66000 66,000
419.04 24" x 5.779 km EOL Spur Pipe Line (Total no of TLP 11 NOS) 1 LS 5500 5,500
419.05 12" x 46.984 Bhodighodi Ambardi Pipeline (Total no of TLP 55 NOS) 1 LS 27500 27,500
419.06 8" x 16.902 kmGSFC sikka Spur Pipeline (Total no of TLP 44 NOS) 1 LS 22000 22,000
419.07 18"X 128.938 KM Morbi-Mundra Pipeline (Total no of TLP 157 NOS) 1 LS 78500 78,500
419.08 12" X 6.65 KM Ajanta Spur (Total no of TLP 10 NOS) 1 LS 5000 5,000
419.09 8" 4.4 KM Sumangal Glass Spur (Total no of TLP 9 NOS) 1 LS 4500 4,500
419.10 8"X 10 KM Electrothem Spur (Total no of TLP 12 NOS) 1 LS 6000 6,000
419.11 8"X 4.3 KM Euro Spur (Total no of TLP 6 NOS) 1 LS 3000 3,000
419.12 12" X 9 KM Metrade Spur (Total no of TLP 20 NOS) 1 LS 10000 10,000
419.13 8" X 1.62 KM Chimique Spur (Total no of TLP 5 NOS) 1 LS 2500 2,500
419.14 6"X 2.957 KM SNF Spurline (Total no of TLP 8 NOS) 1 LS 4000 4,000
419.15 12" X 5 KM Welspun Spurline (Total no of TLP 9 NOS) 1 LS 4500 4,500
419.16 18" X 7.4 KMAnjar-Bhuj Pipeline (ABPL-18") (Total no of TLP 12 NOS) 1 LS 6000 6,000
419.17 12" X 35.2 KM Anjar-Bhuj Pipeline (ABPL-12") (Total no of TLP 45 NOS) 1 LS 22500 22,500
419.18 6" X 5.44 Paddhar Parle Connectivity (Total no of TLP 9 NOS) 1 LS 4500 4,500
419.19 36 " X 67.4 KM Anjar-Mundra Pipeline (AMPL) (Total no of TLP 107 NOS) 1 LS 53500 53,500
419.20 8" X 1.2 KM Chromeni Spur (Total no of TLP 1 NOS) 1 LS 500 500
419.21 24"x 101.77 km Darod - Jafrabad-A (Total no of TLP 120 NOS) 1 LS 60000 60,000
419.22 24"x 110.323 km Darod - Jafrabad-B (Total no of TLP 120 NOS) 1 LS 60000 60,000
419.23 8"x 23.4 km Botad Spurline (Total no of TLP 29 NOS) 1 LS 14500 14,500
419.24 12" x 14.377 km Bhavnagar Spurline (Total no of TLP 18 NOS) 1 LS 9000 9,000
419.25 12" x 75.2 kmTana Amreli Pipeline (Total no of TLP 82 NOS) 1 LS 41000 41,000
419.26 12"x 45.531 Pipavav Gundala Pipeline (Total no of TLP 57 NOS) 1 LS 28500 28,500
419.27 36" x 88.722 km Chhara LNG Connectivity Pipeline (Total no of TLP 125 NOS) 1 LS 62500 62,500
419.28 30"x 3.019 km SWAN FSRU Connectivity Pipeline (Total no of TLP 8 NOS) 1 LS 4000 4,000
420 Servicing and repair of 1250 VA inverter units for emergency lighting system. The works involves cleaning, to check the condition of converter-rectifier units, DC capacitors, Batteries etc. of make "Keprej, Microtek, Sukam". No separate charges shall be paid for manpower, consumables, equipments, tools & tackles used during execution of this activity. 1 Nos. 2,500 2,500
421 Supply and installation of inverter upto 1600 VA of make Microtek/ Sukam/ Luminous 1 Nos. 15,000 15,000
422 Supply and Replacement of Converter-Rectifier unit. 1 Nos. 3,082 3,082
423 Supply and replacement of DC capacitor. 1 Nos. 924 924
424 Supply and Installation of Bolt on/Din-Rail Industrial type Fabricated Finished Enclosure (MCB Distribution Box)of reputed make 0
424.01 4P MCB 4-Way Bolt on Type/Din Rail Type 1 Nos. 3,670 3,670
424.02 4P MCB 8-Way Bolt on Type/Din Rail Type 1 Nos. 4,904 4,904
425 Supply and Installation of Metal-Aacrylic Post Top Lanterns which can accomadate B22 type holder for LED bulb installations 1 Nos. 3,528 3,528
426 Supply & Installation of G.I Pipe/ bend for electrical related works. No separate charges shall be paid for excavation, backfilling, manpower, consumables, equipments, tools & tackles used during execution of this activity. 0
427 Making of Cable entry hole - 4" & 2" on floor by breaking of RCC by using mechanical breaker / Hammer / Manually / abrasive cutting machine and disposal of the demolished materials within a lead of 1KM. including stacking of steel bars and disposal of unserviceable material within 1KM lead. No separate charges shall be paid for manpower, consumables, equipments, handling, tools & tackles used during execution of this activity. 2 per No 3,269 6,538
428 Erection of new HMI console / panel on MS frame/ RCC slab,the job is to be executed as per the direction of the GTL E.I.C. Job include shifting from ground floor to first floor, using hydra crain etc (separate charges shall be paid for MS steel frame & earthing connectivity as per relevent SOR SOR) 1 per panel 16,350 16,350
429 Relocation of panel (Base frame Mounted)- Isolation of the existing panels by Dismantling/ Disconnection of cables, earthings, tag-weldings etc as to make them fully isolated from the existing setUp and shifting & erection of panels on MS frame at new location,the job is to be executed as per the direction of the GTL E.I.C. & GTL requirement (separate charges shall be paid for MS steel frame & earthing connectivity as per relevent SOR SOR). The size of floor mounted panel shall be up to 2100 X 1000 X 1200 (HxDxW) (in mm). The maximum weight shall be consider up to 2 tons. 1 per panel 25,685 211707 25,685
430 Relocation of panel (wall mounted) - Isolation of the existing panels by Dismantling/ Disconnection of cables, earthings, tag-weldings etc as to make them fully isolated from the existing setUp and shifting & erection of panels on wall or on vertical steel frame at new location.the job is to be executed as per the direction of the GTL E.I.C. & GTL requirement (separate charges shall be paid for MS steel frame as per relevent SOR). The maximum weight shall be up to 400 Kg. 1 per panel 12,843 12,843
431 Supply & Installation of A.C. Panel Contactor of 25 amp. ratings as per direction of GTL E-I-C. 3 Nos. 1,906 5,718
432 Supply and Replacement of LED PCB for LED Flood light/Street Light/Flame Proof Light (Bajaj/Philips/CG/Osram/GE Make or other makes as as per the GTL Vendor lsit attached with this tender) of different capacity as follow. Tha Job shall includes removal faulty light from respective lighting pole like flood light, Street light & Flame proof light, replacement of faulty LED PCB & testing & re-instalaltion of the LED Fixture. Arrangement of scaffolding, men, machinery for work at height is in the contractor scope. 0
432.01 PCB For 120 W Flood light 5 Nos. 3,126 15,630
432.02 PCB For 72 W Street light 5 Nos. 3,082 15,410
432.03 PCB For 45 W Flame Proof light 5 Nos. 4,288 21,440
433 Supply and Replacement of LED Driver for LED Flood light/Street Light/Flame Proof Light (Bajaj/Philips/CG/Osram/GE Make or other makes as as per the GTL Vendor lsit attached with this tender) of different capacity as follow. Tha Job shall includes removal faulty light from respective lighting pole like flood light, Street light & Flame proof light, replacement of faulty LED Driver & testing & re-instalaltion of the LED Fixture. Arrangement of scaffolding, men, machinery for work at height is in the contractor scope. 0
433.01 LED Driver For 120 W Flood light 5 Nos. 2,233 11,165
433.02 LED Driver For 72 W Street light 5 Nos. 1,875 9,375
433.03 18W Driver Card for Indoor LED Fixture 5 Nos. 1,652 8,260
433.04 LED Driver For 45 W Flame Proof light 5 Nos. 2,903 14,515
434 Supply and installation of 15W/18W LED ceiling light as as per the GTL Vendor lsit attached with this tender) 10 Nos. 1,339 13,390
435 Supply & Instalaltion of Explosion Proof LED Luminaires complete with LED & Driver. – Zone 1 Zone 2, Gas Group-IIA,IIB,IIC for for Hazardous Area Explosive Dusts Atmospheres specially for Ni-Cd Battery room area of suitable size. Corrosion-resistant fiberglass reinforced polyester body and hinged polycarbonate lens. Latch assembly and elastomer gasket seals against water and dust ingress, IP66 of following rating. Job includes installation on pole (upto 6 mtr height) including SS nut bolts, termination, removal of old fixture etc. No separate charges shall be paid for manpower, consumables,lifting equipments, handling, tools & tackles used during execution of this activity. 0
435.01 Explosion Proof LED Luminaires 40 WATT 1 Nos. 13,848 13,848
435.02 Explosion Proof LED Luminaires 60 WATT 1 Nos. 14,741 14,741
435.03 Explosion Proof LED Luminaires 100 WATT 1 Nos. 18,000 18,000
436 Supply and Installation Air Conditioner Blower Set (inlcuding blower motor) for Indoor Unit 0
437 Supply and Installation of LED Luminaire complete with LED & Driver Gate light 40 W as per the GTL Vendor list having IP66 or more 5 Nos. 7,000 35,000
438 Supply and Installation of PVC type Cable Glands for flexible power cables of grade 650/1100 V and Instrument cables 10 Nos. 200 2,000
439 Supply and Installation of LED Flood light luminaire of 150 W including LED & Driver as per the GTL Vendor list having IP66 or more. Job includes installation on pole (upto 12 mtr height) or terminal building including SS nut bolts, termination, removal of old fixture etc. No separate charges shall be paid for manpower, consumables,lifting equipments, handling, tools & tackles used during execution of this activity. 20 Nos. 10,000 200,000
440 Supply and Installation of LED Flood light luminaire of 200 W including LED & Driver as per the GTL Vendor list having IP66 or more. Job includes installation on pole (upto 12 mtr height) or terminal building including SS nut bolts, termination, removal of old fixture etc. No separate charges shall be paid for manpower, consumables,lifting equipments, handling, tools & tackles used during execution of this activity. 20 Nos. 12,000 240,000
441 Supply and Installation of LED Flood light luminaire of 250 W including LED & Driver as per the GTL Vendor list having IP66 or more. Job includes installation on pole (upto 12 mtr height) or terminal building including SS nut bolts, termination, removal of old fixture etc. No separate charges shall be paid for manpower, consumables,lifting equipments, handling, tools & tackles used during execution of this activity. 20 Nos. 13,000 260,000
442 Supply & installation of UV laminated 4 mm ACP sheet of size (8" x 4") with 3 layer sticker mentioning pipe support No. and installation on pipe support using min. two screws. 10 Nos. 250 2,500
443 Supply and Installation of 36W LED tube light luminaire having Al body with colour temp. 6500K of Bajaj/Philips/CG/Osram/Halonix/Syska/Wipro Make or other makes as per the GTL Vendor list. Job includes installation on ceiling including termination, removal of old fixture etc. No separate charges shall be paid for manpower, consumables,lifting equipments, handling, tools & tackles used during execution of this activity. 5 Nos. 1,500 7,500
444 Supply, Laying & Installation of GI earthing strip – 75 x 6 mm, (Above ground / Under Ground) with over lapping of minimum 75 mm at joints and two consecutive strips to be welded together and applying bitumin on the joint, excavation of required length/depth as per EIC instructions. Separate charges will not be paid for manpower, tools & tackles, consumables used for this activity. 5 Mtr. 600 3,000
445 Supply and installation of 36W LED Luminaire recessed ceiling light of size 2ft x 2 ft complete with LED & Driver of Bajaj/Philips/CG/Osram/GE Make or other makes as as per the GTL Vendor lsit attached with this tender) Job includes installation on ceiling/false ceiling in terminal building including termination, removal of old fixture etc. No separate charges shall be paid for manpower, consumables,lifting equipments, handling, tools & tackles used during execution of this activity. 5 Nos. 2,500 12,500
446 Supply and Installation of LED Flameproof light luminaire complete with LED & Driver 100 W of Bajaj/Philips/CG/Osram/Halonix/Syska/Wipro Make or other makes as per the GTL Vendor list having IP66 or more. Job includes installation on pole (upto 12 mtr height) or terminal building including SS nut bolts, termination, removal of old fixture etc. No separate charges shall be paid for manpower, consumables,lifting equipments, handling, tools & tackles used during execution of this activity. 25 Nos. 5,000 125,000
447 Installation of outdoor lighting fixture including flood light, street light, flameproof light on lighting pole (upto 12 mtr height) or terminal building including SS nut bolts, termination, removal of old fixture etc. No separate charges shall be paid for manpower, consumables,lifting equipments, handling, tools & tackles used during execution of this activity. 15 Nos. 1,000 15,000
448 Installation of indoor lighting fixture including flameproof light, LED battern, recessed ceiling light inside terminal building including fastneres, termination, removal of old fixture etc. No separate charges shall be paid for manpower, consumables,lifting equipments, handling, tools & tackles used during execution of this activity. 5 Nos. 300 1,500
449 Supply and replacement of MS cross arm as per existing design on light pole (upto 12 mtr height) with 2 coat of primer and 2 coat of finished paint. The job includes removal and reinstallation of existing luminaire. No separate charges shall be paid for manpower, consumables,lifting equipments, handling, tools & tackles used during execution of this activity. 5 Kg 2,500 12,500
450 Supply & installation of 8 mm Aluminum Round Conductor along with roof conductor holder for lightening protection 583 Mtr. 350 204,050
451 Supply and installation of T cross and parallel connectors using hexagonal bolt M10X30 high-grade hot dip galvanised. 45 nos. 374 16,830
452 Supply and installation of Polyamide roof cable holder for flat roof closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene 38 nos. 371 14,098
453 Supply and installation of expansion piece with connector on conductors length over 20 meters. For 8 mm Aluminium round conductor road. 21 nos. 535 11,235
454 Supply and Installation of Vertical air terminal with accessories & stand suitable for high wind load. 16 Mtr. 1,780 28,480
455 Supply and installation of Explosion-proof spark gap for lightning equipotential bonding in hazardous areas 2 nos. 39,183 78,366
456 Supply and installation of Cross connector for Flat strip suitable for 30mm Galvanised steel strip and max 40. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. 32 nos. 469 15,008
457 Supply and installation of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. 8 nos. 1,635 13,080
458 Supply and installation of flat conductor holder suitable for strip. Installed with 2 hexagonal bolts. 25 nos. 485 12,125
459 Supply and installation of universal clamp made of SS to connect rod with flat conductor 25 nos. 1,500 37,500
460 Supply and backfilling of earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested 25 nos. 4,797 119,925
461 Supply and installatin of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. 613 Mtr. 693 424,809
462 Supply and Test Joint suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer, made of hot dipped galvanised iron & Installed with 4 hexagonal bolts M8*25 with M8 hexagonal nuts 25 nos. 424 10,600
463 Supply and installation of TYPE-1 SPD, 3PHASE Lightning current arresting capacity to 50 kA (10/350) per pole and up to 150 kA (10/350) in total. 17 nos. 13,818 234,906
464 Supply and installation of TYPE-1 SPD N-PE Discharge current (10/350 µs) upto 125 kA. 3 nos. 17,217 51,651
465 Supply and installtion of Type-1+2 3PHASE+NPE 320 For lightning current equipotential bonding as per (IEC 62305), with lightning current arresting capacity of 12.5 kA (10/350 µs) per pole and up to 50 kA (10/350 µs) total. 7 nos. 35,953 251,671
466 Supply and installation of Type- 2 3PHASE+NPE Surge voltage protection for equipotential bonding as per (IEC 60364-4-44), with discharge capacity up to 40 kA (8/20 µs) per pole using high-performance varistors. 13 nos. 15,572 202,436
467 Supply and Replacement of LED PCB for LED Flood light/Street Light/Flame Proof Light (Bajaj/Philips/CG/Osram/GE Make or other makes as as per the GTL Vendor lsit attached with this tender) of different capacity as follow. Tha Job shall includes removal faulty light from respective lighting pole like flood light, Street light & Flame proof light, replacement of faulty LED PCB & testing & re-instalaltion of the LED Fixture. Arrangement of scaffolding, men, machinery for work at height is in the contractor scope. 0
467.01 PCB For 100 W Flame Proof light 12 Nos. 1,500 18,000
467.02 PCB For 150 W Flood light 4 Nos. 1,500 6,000
467.03 PCB For 200 W Flood light 7 Nos. 2,000 14,000
467.04 PCB For 250 W Flood light 7 Nos. 2,500 17,500
468 Supply and Replacement of LED Driver for LED Flood light/Street Light/Flame Proof Light (Bajaj/Philips/CG/Osram/GE Make or other makes as as per the GTL Vendor lsit attached with this tender) of different capacity as follow. Tha Job shall includes removal faulty light from respective lighting pole like flood light, Street light & Flame proof light, replacement of faulty LED Driver & testing & re-instalaltion of the LED Fixture. Arrangement of scaffolding, men, machinery for work at height is in the contractor scope. 0
468.01 LED Driver For 36W LED Light. 7 Nos. 500 3,500
468.02 LED Driver For 100 W Flame Proof light 12 Nos. 800 9,600
468.03 LED Driver For 150 W Flood light 4 Ns. 1,000 4,000
468.04 LED Driver For 200 W Flood light 7 Nos. 1,500 10,500
468.05 LED Driver For 250 W Flood light 7 Nos. 1,800 12,600
469 Supply and Replacement of various spares including Panel servicing/operational check, removal of faulty parts & handling with all tools / tackles / manpower/machinery & consumables etc. as per GTL EIC instructions. 0
469.01 Nylon Gear 12 Teeth 1 Nos. 350 350
469.02 Nylon Gear 48 Teeth 1 Nos. 1,200 1,200
469.03 Nylon Gear 96 Teeth 1 Nos. 1,800 1,800
469.04 Cooling Fan -230 V AC, 6" 1 Nos. 300 300
469.05 Cooling Fan -230 V AC, 4" 1 Nos. 400 400
469.06 Servo control Meter/Display Unit 1 Nos. 1,000 1,000
469.07 Rotary Bypass Switch (125/140 Amps) 1 Nos. 5,000 5,000
469.08 Fuse with base upto 160 Amp. 1 Nos. 5,000 5,000
469.09 Micro controlled PCB 1 Nos. 5,000 5,000
469.10 3 pole Power contactor Upto 50 A 1 Nos. 4,000 4,000
469.11 3 pole Power contactor Upto 100 A 1 Nos. 5,000 5,000
469.12 3 pole Power contactor Upto 140 A 1 Nos. 7,000 7,000
469.13 Wiper arm assembly of Variac 1 Nos. 1,500 1,500
469.14 Multifunctional Meter 1 Nos. 2,500 2,500
469.15 Toggle Switch 3A 230V 1 Nos. 500 500
469.16 Single phase preventer 1 Nos. 1,000 1,000
469.17 AC Surge protection device (SPD) Type 2, 3 phase + Neutral (3+1) with discharge capacity up to 40 kA 1 Nos. 1,500 1,500
469.18 Synchronous Motor - 240V AC (Servo Motor) having Torque 3 Kg-cm 1 Nos. 4,000 4,000
469.19 Synchronous Motor - 240V AC (Servo Motor) having Torque 7 Kg-cm 1 Nos. 4,500 4,500
469.20 Synchronous Motor - 240V AC (Servo Motor) having Torque 10 Kg-cm 1 Nos. 5,000 5,000
469.21 RC network for Servo Motor having torque 3 Kg-cm 1 Nos. 1,200 1,200
469.22 RC network for Servo Motor having torque 7 Kg-cm 1 Nos. 1,500 1,500
469.23 RC network for Servo Motor having torque 10 Kg-cm 1 Nos. 1,800 1,800
470 Supply and installation of Isolation Transformer (Air Cooled) for following ratings with copper winding and Class H insulation. The scope of work includes dismantling of the existing transformer, supply of new transformer, installation, testing & commissioning. No separate charges shall be paid for materials, manpower, consumables, tools & tackles & transportation. 0
470.01 3 phase Isolation Transformer- 63 KVA 1 Nos. 80,000 80,000
470.02 3 phase Isolation Transformer- 75 KVA 1 Nos. 90,000 90,000
470.03 3 phase Isolation Transformer- 80 KVA 1 Nos. 100,000 100,000
470.04 3 phase Isolation Transformer- 100 KVA 1 Nos. 130,000 130,000
471 Supply and installation of Buck Boost Transformer for following ratings with copper winding and Class H insulation. The scope of work includes dismantling of the existing transformer, supply of new transformer, installation, testing & commissioning. No separate charges shall be paid for materials, manpower, consumables, tools & tackles & transportation. 0
471.01 Buck Boost Transformer- 63 KVA 1 Nos. 10,000 10,000
471.02 Buck Boost Transformer- 75 KVA 1 Nos. 12,000 12,000
471.03 Buck Boost Transformer- 80 KVA 1 Nos. 15,000 15,000
471.04 Buck Boost Transformer- 100 KVA 1 Nos. 20,000 20,000
472 Supply and installation of Variac (Auto Transformer/Variable Transformer) for following ratings with copper winding and Class H insulation, complete as per approved design. The scope of work includes dismantling of the existing transformer, supply of new transformer, installation, testing & commissioning. No separate charges shall be paid for materials, manpower, consumables, tools & tackles & transportation. 0
472.01 Suitable for 63 KVA Servo 1 Nos. 5,000 5,000
472.02 Suitable for 75 KVA Servo 1 Nos. 7,000 7,000
472.03 Suitable for 80 KVA Servo 1 Nos. 8,000 8,000
472.04 Suitable for 100 KVA Servo 1 Nos. 10,000 10,000
473 Supply and replacement of Current Transformer 0
474 Supply and mobilization of Nitrogen gas of commercial grade in loose Cylinder / banks of individual cylinder capacity 7m3 at a pressure of 150 kg/Sq cm with all connecting hoses and de-mobilization after completion of job including loading, unloading, handling Cylinder pressure regulator and pressure gauge with accessories. No separate charges shall be paid for manpower, tools & tackles, lifting equipment's used during this activity. 340 Nos. 1,000 3000600 340,000
475 Removal, Refilling, hydrotesting & re-installation after painting of CO2 Gas cylinders used for flooding system of Water Capacity: 68 Ltr/N2 cylinder Capacity 48 ltr including to & fro transportation. (CO2 refilling shall be carried out thru PESO approved vendor only). No separate charges shall be paid for manpower, tools & tackles, lifting equipment's used during this activity. 208 Nos. 8,000 213532 1,664,000
476 Supply ,Laying & Termination of PVC insulated, FRLS Outer sheathed, PVC Inner Sheathed Cable Voltage grade 650 / 1100 Volts of following sizes Above-Ground on cable trays, supported on steel structures, in ready made trenches. The rates shall include the supply and fixing of aluminium number tags, G.I. saddles / clamps, saddle bars, lugs, ferrules, double compression type SS glands, etc, Cable will be supplied by GTL at designated stores. No separate charges shall be paid for transportation of cables from GTL designated stores to the site, manpower, consumables, equipment's, tools & tackles used during execution of this activity 0
476.01 Instrument cable up to 2P x 1.5sqmm armoured cable 10 Mtr. 147 210878 1,470
476.02 Instrument cable up to 6P x 1.5sqmm armoured cable 10 Mtr. 147 210879 1,470
476.03 Instrument cable up to 12P x 1.5sqmm armoured cable 10 Mtr. 172 210880 1,720
476.04 2 core x 1.5 mm2 Armoured Shield Data cable 10 Mtr. 531 209116 5,310
476.05 3 C x 1 Sq mm Armoured Power Cable 10 Mtr.. 295 210901 2,950
476.06 Flexible cable upto 1 C x 6 sq. mm. cable 10 Mtr. 180 1,800
476.07 Flexible cable upto 3 C x 6 sq. mm. cable 10 Mtr. 240 2,400
476.08 Non-FRLS Flexible Earthing cable of size upto 25 sq. mm. 10 Mtr. 550 5,500
477 Supply & Installation of GI Cable Trays with cover on MS steel support. All Accessories shall be in the scope of contractor like MS angle support , channel,Fastners, Clamp, Cable tie etc. as per below mentioned size 0
477.01 Perforated Cable tray with cover 450 mm 10 per Mtr. 1,373 500754 13,730
477.02 Perforated Cable tray with cover 300 mm 10 per Mtr. 983 500755 9,830
477.03 Perforated Cable tray with cover 150 mm 10 per Mtr. 628 500756 6,280
477.04 Perforated Cable tray with cover 100 mm 10 per Mtr. 452 500757 4,520
477.05 Ladder type Cable tray 450 mm 10 per Mtr. 1,348 500758 13,480
477.06 Ladder type Cable tray 300 mm 10 per Mtr. 1,204 500759 12,040
477.07 Ladder type Cable tray 150 mm 10 per Mtr. 839 500760 8,390
478 Laying & Termination of PVC insulated, FRLS Outer sheathed, PVC Inner Sheathed Instrumentation Cable Voltage grade 650 / 1100 Volts of following sizes Under-Ground and / or pull through pipes including excavation and backfilling etc. Work includes excavation of trench of average 0.5 meter wide & up to 1.2 meter depth with all appropriate tools & tackles( manual work inside terminals). Layer of sand shall be of 100 mm thick & brick layer shall be laid on cable for protection and back filling of trench after completion of work. work includes carting of surplus earth/debris and handling/unrolling of cable, supply of aluminium tags, lugs, ferrules, double compression type SS glands, etc, including transportation with all labour and materials as per the specifications, drawings and directions of Engineer-in-charge . The insulation resistance of cable has to be checked & reported before commissioning. No separate charges shall be paid for excavation, backfilling, manpower, consumables, equipment's, tools & tackles used during execution of this activity 0
478.01 Instrument cable up to 1P x 1.5sqmm armoured cable 15 Mtr. 437 208702 6,555
478.02 Instrument cable up to 2P x 1.5sqmm armoured cable 15 Mtr. 491 208703 7,365
478.03 Instrument cable up to 6P x 1.5sqmm armoured cable 15 Mtr. 711 209117 10,665
478.04 Instrument cable up to 12P x 1.5sqmm armoured cable 15 Mtr. 991 209118 14,865
479 Supply and Installation of "U" Clamps of SS material of standard type with NPT at bolting end including polyethylene insulation/conduit for "U" Clamps including nuts and washers for different size of pipe clamps as per instruction of EIC. No separate charges shall be paid for manpower, consumables, equipment's, tools & tackles used during execution of this activity. This include removal of old rusted U Clamps. 0
480 Painting of lighting pole/ Solar pole / OPD Pole//PGD Pole/ Stack including surface preparation, supply of paint and application of 2 coat of high build chlorinated rubber / zinc phosphate primer and two coats of finished paint of epoxy paint of Silver colour approved make as per the GTL Vendor list attached with this tender to give an even shade after proper removal of existing paint by suitable method and clearing of surface free from foreign materials. No separate charges shall be paid for manpower, consumables, equipment's, letter writing of tag Number, tools & tackles used during execution of this activity. 0
480.02 Upto 4.5 Meter Height Pole (OPGD/PGD etc pole in process area) 60 Nos. 2,500 212609 150,000
480.03 Upto 6 Meter Height Pole (Solar Light) 3 Nos. 2,500 7,500
480.04 6.1 Meter to 9 Meter Height Pole 60 Nos. 3,000 180,000
480.05 9.1 Meter to 11 Meter Height Pole 400 Nos. 3,500 1,400,000
481 Supply & Installation of 12V 18 AH SMF Battery 1 Nos. 1568 3000530 1,568
482 Supply & Installation of GTL approved makes Cooling/Ventilation fan in control panel axial fan 220V 0
483 Supply of panel cover for modular piano switches of different sizes. 10 Nos. 599 211673 5,990
484 Supply & Replacement of door hinges in instrument local control panel / RTU panel /Electrical panels. 41 Nos. 925 500656 37,925
485 Supply & Replacement of door Lock in instrument local control panel / RTU panel /Electrical panels/UPS . 55 Nos. 1,307 500657 71,885
486 Supply & Replacement of light and fixture for panel door in instrument local control panel / RTU panel. 25 Nos. 1,034 500658 25,850
487 Supply & Replacement of Selector switch in Instrument local control panel. 20 Nos. 1,199 500659 23,980
488 Supply & Replacement of Panel Hooter, Supply Voltage 230Vac / 24 Vdc as per GTL requirement for instrument panel and F & G and CO2 flooding system. 3 Nos. 3,269 500660 9,807
489 Supply & Replacement of FLP & WP Field Hooter , Supply Voltage 230Vac / 24 Vdc as per GTL requirement for Gas Detection System. 3 Nos. 6,649 500661 19,947
490 Supply & Replacement of FLP & WP Flasher (Yellow/Red) , Supply Voltage 230Vac / 24 Vdc as per GTL requirement for Gas Detection System. 3 Nos. 8,175 500662 24,525
491 Supply & replacement of Electrical Fire Exit Glow Board. (Green Color) 30 Nos. 1,743 500667 52,290
492 Supply & Replacement of Power Supply Converter, (230 Vac to 12 Vdc/24 Vdc, -48 Vdc to 24 Vdc/12 Vdc) 4 Nos. 4,500 500668 18,000
493 Removal and Re-installation of Regulator Valve ( Either Active or Monitor) of size mentioned below. Size of regulator valve to be considered as per Inlet size of Regulator. No separate charges shall be paid for manpower, consumables, lifting equipments,Valve operation, venting activity,dismenteling & installation of tubing, tools & tackles used during execution of this activity. Gasket shall be supplied by GTL at designated store. 0
494 Removal and Re-installation of SSV Valve of size mentioned below. No separate charges shall be paid for manpower, consumables, lifting equipment's, tools & tackles used during execution of this activity. Maintenance to ne perform Gasket shall be supplied by GTL at designated store. 0
495 Removal and Re-installation of Flow Control Valve of size mentioned below. No separate charges shall be paid for manpower, consumables, lifting equipment's, tools & tackles used during execution of this activity. Gasket shall be supplied by GTL at designated store. 0
496 Preparation of cable schedule and termination detailing of existing cables of all panels the job is to be executed as per the direction of the GTL E.I.C. & GTL requirement. 1 per panel 8,219 211706 8,219
497 Supply laying and Termination (using Conduit, Rojet Box,temrinal block, crimping, connectors) of telecom & network cables. The Insulation Resistance of cable has to be checked & reported before commissioning. No separate charges shall be paid for excavation, backfilling, manpower, consumables, equipment's, tools & tackles used during execution of this activity. 0
497.01 Polythene (Solid/Foam Skin) Insulated Jelly Filled Cables Up to 5 Pair 1 Mtr. 678 3000596 678
497.02 Polythene (Solid/Foam Skin) Insulated Jelly Filled Cables Up to 10 Pair 1 Mtr. 884 3000597 884
497.03 Polythene (Solid/Foam Skin) Insulated Jelly Filled Cables Up to 50 Pair 1 Mtr. 884 211749 884
497.04 Flexible 2 pair Telephone cable 1 Mtr. 298 210912 298
497.05 Up to 1 sqmm control cable 1 Mtr. 350 211750 350
497.06 RG-11 Video Cable 1 Mtr. 300 3000598 300
497.07 Optical Fiber Patch chord with connector as per GTL requirement- 1 pair - Up to 25 meter length 1 Mtr. 623 213203 623
497.08 CAT 6 Ethernet cable 1 Mtr. 300 211752 300
498 Supply & installation of Gas detection System pole 0
498.01 Pole for Open path gas detector--150mm dia pole with 4.5 mtr height 1 Nos. 2,680 212642 2,680
498.02 Pole for point gas detector 2" Pole Dia- 2.0 mtr height 1 Nos. 2,233 212643 2,233
499 Supply and Installation of CO2 /FM 200 Flooding System spares as follows. 0
499.01 Supply & Installation Master card (10-036 A) 9 Nos. 20,377 212751 183,393
499.02 Supply & Installation Slave card (10-048B) 9 Nos. 16,587 212752 149,283
499.03 Repairing of Master card 11 Nos. 11,847 212753 130,317
499.04 Repairing of Slave card 17 Nos. 9,951 212754 169,167
499.05 Supply & Installation 7805 IC with Heat Sink 9 Nos. 4,739 212755 42,651
499.06 Supply & Installation Battery charger card 9 Nos. 2,369 212756 21,321
499.07 Supply & Installation 15017 card 9 Nos. 4,739 212757 42,651
499.08 Supply & Installation SMPS 15 Nos. 4,904 212758 73,560
499.09 Supply & Installation new EPROM set with Programming 9 Nos. 12,795 212759 115,155
499.10 Supply & Installation relay card 9 Nos. 16,587 212760 149,283
499.11 Supply & Installation PCB card 9 Nos. 13,743 212761 123,687
499.12 Supply & Installation memory enable lock & key 9 Nos. 8,056 212762 72,504
499.13 Supply & Installation multicriteria Photo electric Smoke/Thermal/Optical smoke Detector 9 Nos. 2,891 212763 26,019
499.14 Neck Ring for CO2 cylinder 25 Nos. 1,184 212764 29,600
499.15 Manual call point 17 Nos. 2,071 212766 35,207
499.16 Supply & Installation Valve for Master Cylinder 17 Nos. 34,595 212767 588,115
499.17 Supply & Installation Valve for Slave Cylinder 32 Nos. 34,595 212768 1,107,040
499.18 Ball Valve with Electrical Actuator 15 Nos. 43,125 212769 646,875
499.19 Hose pipe (3/8”) with Hydro test certificate 30 Nos. 1,564 212770 46,920
499.20 Hose pipe (1/4”) with Hydro test certificate 30 Nos. 1,199 212771 35,970
499.21 Linear Heat Sensor cable 60 R Mtr 966 212772 57,960
499.22 Hooter with flasher 6 Nos. 2,037 212773 12,222
499.23 Electric Siren (1 KM range) 6 Nos. 6,113 212774 36,678
499.24 Manual release push Button with cover 15 Nos. 520 212776 7,800
499.25 Supply & Installation Keypad card 15 Nos. 2,891 212777 43,365
499.26 Supply & Installation Siren Electronic Card 15 Nos. 5,260 212779 78,900
499.27 Supply & Installation Zone Display card 15 Nos. 12,795 212780 191,925
499.28 Electrical LED Type Warning Sign Board 15 Nos. 2,449 212781 36,735
499.29 Supply & Installation Pressure Switch 15 Nos. 6,236 212782 93,540
499.30 Supply & Installation NRV (Connected to Header) 15 Nos. 5,165 212783 77,475
500 Supply and replacement of MIMIC Diagram 15 Nos 1,943 212789 29,145
501 Supply and replacement of Limit Switch of cylinder weight indicator(including Neck Ring and Hanging Road) 82 Nos 520 212790 42,640
502 Supply and replacement of Cylinder weight indicator Interconnecting cable along with compatible connector 50 Nos 11,847 212765 592,350
503 Supply and Installation of FM200 Flooding System spares as follows. 0
503.02 Mode Selection Module -1 : (FA:5:M:517 A) 3 Nos. 4,739 212793 14,217
503.05 Output Relay board (FA:5:518:A) 3 Nos. 2,369 212796 7,107
503.06 Power Module : (FAS:5:PS:501) 3 Nos. 7,108 212797 21,324
503.07 Monitor Module: (FAS:5:MM:502-A) 3 Nos. 4,739 212798 14,217
503.08 Control Module : ( FAS:5:CM:503-A) 3 Nos. 7,108 212799 21,324
503.09 Annunciator Window PCB: AA-266A 3 Nos. 4,739 212800 14,217
503.13 Discharge valve (Part no:00-100000-000, make-CRYPTZO) for FM200 Cylinder 6 No 6,161 212784 36,966
503.14 Discharge Hose (Part No: 14-000001-000, Make-CRYPTZO) for FM200 Cylinder 15 No 711 212785 10,665
503.15 Electrical cum manual actuator (Part No: 14-000031-000, Make-CRYPTZO) for FM200 Cylinder 6 No 11,374 212786 68,244
503.16 Check valve (Part No: 14-000060-000, Make-CRYPTZO) for FM200 System 6 No 5,686 212787 34,116
504 Removal, hydrotesting, Refilling & re-installation of FM 200 Gas cylinders used for flooding system of Water Capacity: 68/80/120 Ltr, Pressure: 48 Kg/Cm2 including to & fro transportation. (FM200 refilling shall be carried out thru PESO approved vendor only). No separate charges shall be paid for manpower, tools & tackles, lifting equipment's used during this activity. 0
504.01 FM200 gas Cylinder with 68/80/120 Ltr WC 3 No 284,345 212806 853,035
505 Supply and Installation of LED Gate light 40 W with fixture 15 Nos. 15,639 212809 234,585
506 Supply, installation/replacement of up to 6" Dial and up to 210 Bar range Pressure Gauge 15 Nos. 14,217 212896 213,255
507 Supply, installation/replacement of up to 6" Dial and up to 100 Deg C Temperature Gauge 10 Nos. 14,217 212897 142,170
508 Supply, installation/replacement of up to 6" Dial and 0-2 Bar Differential Pressure Gauge 12 Nos. 11,847 212898 142,164
509 Supply, installation/replacement of Analog Input Barrier approved make 12 Nos. 4,739 212901 56,868
510 Supply, installation/replacement of Analog Output Barrier approved make 12 Nos. 4,739 212902 56,868
511 Supply, installation/replacement of Digital Input Barrier approved make 12 Nos. 5,781 212903 69,372
512 Supply, installation/replacement of Digital Output Barrier approved make 12 Nos. 5,781 212904 69,372
513 Supply, installation/replacement of Pulse Input Barrier approved make 13 Nos. 4,265 212905 55,445
514 Supply, installation/replacement of Proximity Switch (Make-Pepperl+Fuchs, Model No-NJ5-11-N-G) 26 Nos. 6,634 212906 172,484
515 Supply, installation/replacement of Proximity Switch (Make-Pepperl+Fuchs, Model No-NCB2-V3-NO/NJ2-12GK-N) 26 Nos. 6,634 212907 172,484
516 Supply of Helium Gas (Helium Gas For Gas Chromatograph) 1) ( Purity of Gas 99.999%, (Grade 5) 2) Allowable impurity level (V/V)% (V/V%, PPM, MAX: - Ar < 2, O2 < 2, H2O <2, CO+CO2 <1, Thc <0.5, Cl2+Hg+S-Comp <0), 3) Cylinder Capacity 47 Ltrs Water Capacity , 4) Cylinder filling Pressure -150 Kg/cm² (+/- 5 kg/cm2), 5) Helium Gas Volume per Cylinder- 7.0 m³ ,6) Stability Gas -Stability of Helium Gas must be valid for at least One Year from the date of re-filling. , 7) Supply of Cylinders -Refilling to be done in Cylinders supplied by GTL, 8) Freight, loading and unloading of Cylinders and door delivery are in vendor scope, To and Fro transportation, 9) Gas composition Certificate-Lab analysis Certificate Required for each cylinder with traceability. 10) Lab Facility-The Bidder shall preferably have in-house laboratory infrastructure equipped with analysers and instruments necessary for helium gas analysis. In the event that such facilities are not available with the Bidder, the analysis and testing of helium gas shall be mandatorily undertaken at either (i) the Manufacturer’s laboratory, or (ii) any reputed/NABL-accredited laboratory. 30 M3 3,000 213533 90,000
517 Supply of Helium Gas Cylinder-46.7 Litres (CCOE approved test certificate) 1 No 35,000 35,000
518 Supply and install He Cylinder Valve Replacement. 1 No 650 650
519 Supply and install He Cylinder Valve Gland Nut 1 No 250 250
520 Supply and install He Cylinder Valve Spindle 1 No 250 250
521 Degreasing of He Cylinder 1 No 650 650
522 Painting of He Cylinder 1 No 350 350
523 Replacement of Cylinder Cap 1 No 250 250
524 Supply and install Helium Cylinder Regulator (inlet 150 KG/CM2, outlet -0-15 KG/CM2) 1 No 7000 7,000
525 Hydro testing of Cylinder (which are due for hydro test, shall be Hydro tested at 225 Kg/cm² and CCOE approved test certificate has to be submitted. Vendor has to quote separately for Hydro testing charges) 3 No 1800 213535 5,400
526 Supply, Fabrication and Installation of Aluminium Canopy for Field Instruments, Open Path Gas Detectors, Flow Computers. Dimensions of the canopy as per field instrument actual at site and instruction as per EIC 3 Kg 750 2,250
527 Supply, Fabrication and Installation of G.I Sheet Canopy for Field Instruments, Open Path Gas Detectors, Flow Computers. Dimensions of the canopy as per field instrument actual at site and instruction as per EIC 3 Kg 240 720
528 Checking & Maintenance of Instrument Panel: The job shall include cleaning of the panel from outside and inside by vaccum cleaner / Manual, checking of Indication Lamp, Hooter, Fuses, and sealing of the open cable entries by PVC/GI blind plug . The job shall also include Identification, termination & proper Dressing of Cable. All required tools, tackles, manpower and PVC/GI blind plug shall be in contractor's scope. The report submission in GTL approved format is also part of the job. The job shall be caarried out by qualified instrument technician /electrician. 3 Nos. 2,359 7,077
529 Dual Channel Bargraph indicator (Model : 40005E, Make : Masibus) 3 Nos. 5,807 17,421
530 Single Channel Bargraph indicator (Model : 40005E, Make : Masibus) 3 Nos. 4,020 12,060
531 Directional Valve for Co2 flooding/FM-200 System 3 Nos 3,000 9,000
532 Solenoid Coil for Co2 /FM-200 Cylinder 3 Nos 5,000 15,000
533 Modification and Fabrication of Manifold for existing FM200 System at site after replacement of Discharge valve, Hose, Elect cum manual actuator and check valve (CRYPTZO make) for FM200 Cylinder and Pnuematic testing of piping 12 No 4,739 56,868
534 Removal, hydrotesting & re-installation of Hose pipe (interconnecting & discharge) for Fire Alarm & CO2/FM200 Flooding System (Testing shall be carried out thru PESO approved vendor only). No separate charges shall be paid for manpower, tools & tackles, to & fro transporatation used during this activity. Note : Testing at 1.5 times of working pressure 154 No 350 53,900
535 Removal, Refilling (HFC227 Ea) & re-installation of Gas cylinders used for flooding system of Water Capacity: 68/80/120 Ltr. (Refilling shall be carried out thru PESO approved vendor only). No separate charges shall be paid for manpower, tools & tackles, lifting equipments, to & fro transporatation used during this activity. Note : Refilling gas qty will be same as existing filled cylinder before testing Note : Refilling of Cylinder shall be considered as per SOR No: 2.712.1 / 2.712.2 / 2.712.3 (based on Cylinder WC) or 2.712.4.Only one SOR rate is applicable which is decided by EIC/BIC 0
535.01 FM200 gas Cylinder with 68 Ltr WC 1 No 120,000 120,000
535.02 FM200 gas Cylinder with 80 Ltr WC 7 No 150,000 1,050,000
535.03 (HFC227 Ea) gas refilling Note: Decanting the FM200 gas from filled cylinder and refilling of the same after hydro-test with required top up gas. Only top up gas shall be consided for gas refilling qty in Kg 455 Kg 2,500 1,137,500
536 Spares for Addressable Fire Alarm and Flooding System (Notifire by Honeywell) 0
536.01 ADDRESSABLE 1 LOOP FIRE ALARM PANEL, Make : NOTIFIER BY HONEYWELL, Model:NFS-320E 1 No. 390,000 390,000
536.03 Display/Keypad Assembly (KDM-R2) 1 No. 120,000 120,000
536.04 Power Supply Card (AMPS-24/E) 1 No. 110,000 110,000
536.05 Bettery Charger Module (CPS-24/E) 1 No. 70,000 70,000
536.06 SLC loop card (LEM320) 1 No. 26,000 26,000
536.07 RS-232/Rs-485 Interface card 1 No. 240,000 240,000
536.08 GAS RELEASE MODULE FOR ADDRESSABLE FIRE ALARM PANEL,Make : NOTIFIER BY HONEYWELL, Model:RP-2002 E 1 No. 170,000 170,000
536.09 Remote LCD Annunciator (N-ANN-80) 1 No. 65,000 65,000
536.10 LED Annunciator Module ( N-ANN-LED) 1 No. 78,000 78,000
536.11 Remote Red LED (N-ANN-RLED) 1 No. 65,000 65,000
536.12 ADDRESSABLE MULTI DEECTOR WITH BASE, Make : NOTIFIER BY HONEYWELL, Model: FSP-951T 1 No. 3,500 3,500
536.13 ADDRESSABLE HEAT DETECTOR WITH BASE, Make : NOTIFIER BY HONEYWELL, Model : FST-951R 1 No. 3,300 3,300
536.14 ADDRESSABLE CONTROL MODULE, Make: NOTIFIER BY HONEYWELL, Model: FCM-1(A) 1 No. 4,500 4,500
536.15 ADDRESSABLE RELAY MODULE , Make: NOTIFIER BY HONEYWELL, Model: FRM-1(A) 1 No. 4,500 4,500
536.16 ADDRESSABLE MONITOR MODULE, Make: NOTIFIER BY HONEYWELL, Model: FMM-1(A) 1 No. 4,500 4,500
537 Supply of Solo Smoke Detector Tester (Aerosol 3, make - Detectortesters, Qty - 250 ML) for checking of smoke Detectors 11 No 5,500 60,500
538 Supply, installation/replacement of Alarm Annunciator (Make -Minilec, Model No- MBAS0600, Windows-12) 4 Nos. 9,004 36,016
539 Troubleshooting of Biffi / Rotork / Shafer (Emerson)/Schuck make Actuator. The job shall be carried out by qualified OEM service engineer. 3 Per 8 Hour 25,000 75,000
540 Laying & Termination of PVC insulated, FRLS Outer sheathed, PVC Inner Sheathed Cable Voltage grade 650 / 1100 Volts of following sizes Above-Ground on cable trays, supported on steel structures, in ready made trenches. The rates shall include the supply and fixing of aluminium number tags, G.I. saddles / clamps, saddle bars, lugs, ferrules, double compression type SS glands, etc, Cable will be supplied by GTL at designated stores. No separate charges shall be paid for transportation of cables from GTL designated stores to the site, manpower, consumables, equipment's, tools & tackles used during execution of this activity 0
540.01 Instrument cable up to 2P x 1.5sqmm armoured cable 30 Mtr. 174 5,220
540.02 Instrument cable up to 6P x 1.5sqmm armoured cable 30 Mtr. 270 8,100
540.03 Instrument cable up to 12P x 1.5sqmm armoured cable 30 Mtr. 457 13,710
540.04 2 core x 1.5 mm2 Armoured Shield Data cable 10 Mtr. 320 3,200
540.05 3 C x 1 Sq mm Armoured Power Cable 30 Mtr.. 120 3,600
541 Supply, Laying & Termination of PVC insulated, FRLS Outer sheathed, PVC Inner Sheathed Instrumentation Cable Voltage grade 650 / 1100 Volts of following sizes Under-Ground and / or pull through pipes including excavation and backfilling etc. Work includes excavation of trench of average 0.5 meter wide & up to 1.2 meter depth with all appropriate tools & tackles( manual work inside terminals). Layer of sand shall be of 100 mm thick & brick layer shall be laid on cable for protection and back filling of trench after completion of work. work includes carting of surplus earth/debris and handling/unrolling of cable, supply of aluminium tags, lugs, ferrules, double compression type SS glands, etc, including transportation with all labour and materials as per the specifications, drawings and directions of Engineer-in-charge . The insulation resistance of cable has to be checked & reported before commissioning. No separate charges shall be paid for excavation, backfilling, manpower, consumables, equipment's, tools & tackles used during execution of this activity 0
541.01 Instrument cable up to 1P x 1.5sqmm armoured cable 30 Mtr. 437 13,110
541.02 Instrument cable up to 2P x 1.5sqmm armoured cable 30 Mtr. 491 14,730
541.03 Instrument cable up to 6P x 1.5sqmm armoured cable 30 Mtr. 711 21,330
541.04 Instrument cable up to 12P x 1.5sqmm armoured cable 30 Mtr. 991 29,730
542 Arrangement and supply of water in tanker/truck/lorry only for fire fighting during emergency/mock drill. 10,000 Litres 2 Nos. 5,000 208676 10,000
543 Arrangement of fire tender during critical/Hot work/mock drill/Shutdown activities 3 Per 8 Hours 35,000 212886 105,000
544 Arrangement of ambulance during critical/Hot work/mock drill/Shutdown activities 3 Per 8 Hours 25,000 212887 75,000
545 Spares of Fire Extinguishers used during Maintenance and HSE items 0
545.01 Painting of up to 2 kg. CO2 Cylinder 20 Nos 189 210137 3,780
545.02 Painting of 4.5 kg. CO2 Cylinder 25 Nos 284 210138 7,100
545.03 Painting of 6.5 kg. CO2 Cylinder 12 Nos 331 211550 3,972
545.04 Painting of 9.0 Kg. CO2 Cylinder 117 Nos 427 210139 49,959
545.05 Painting of ABC F/E 6.0 Kg (SP). 19 Nos 236 212567 4,484
545.06 Painting of DCP FE 9.0 Kg 24 Nos 284 210142 6,816
545.07 Painting of DCP/ABC F/E 25.0 Kg 66 Nos 473 210144 31,218
545.08 Painting of DCP/ABC F/E 75.0 Kg 28 Nos 711 210145 19,908
545.09 Painting of ABC F/E 2 Kg. Capacity(SP) 14 Nos 189 212911 2,646
545.10 Painting of ABC F/E 9 Kg. Capacity (S P) 20 Nos 284 210522 5,680
545.11 Hydro Pressure Test up to 2 kg CO2 Cylinder 30 Nos 427 210146 12,810
545.12 Hydro Pressure 4.5 kg CO2 Cylinder 21 Nos 520 210147 10,920
545.13 Hydro Pressure Test 6.5kg CO2 Cylinder 12 Nos 520 211551 6,240
545.14 Hydro Pressure Test 09.0 Kg. CO2 Cylinder 117 Nos 711 210148 83,187
545.15 Hydro Pressure Test ABC 6 Kg FE (SP) 15 Nos 236 212570 3,540
545.16 Hydro Pressure Test 09 Kg. ABC Cylinder(SP) 22 Nos 236 210526 5,192
545.17 Hydro Pressure Test DCP/ABC 25 Kg FE 73 Nos 473 210153 34,529
545.18 Hydro Pressure Test DCP/ABC 75 Kg FE 24 Nos 711 210154 17,064
545.19 Hydro Pressures ABC F/E 2 Kg Capacity 8 Nos 236 213194 1,888
545.20 Refilling of 2.0 kg CO2 Cylinder 28 Nos 427 210122 11,956
545.21 Refilling of 4.5 kg CO2 MS body 21 Nos 545 212994 11,445
545.22 Refilling of 6.5 kg CO2 Cylinder 12 Nos 639 212912 7,668
545.23 Refilling of 9.0 kg CO2 Cylinder 117 Nos 734 210125 85,878
545.24 Refilling of 9.0 kg DCP F/E 7 Nos 616 213100 4,312
545.25 Refilling of 25 kg ABC F/E -With 90% MAP Powder & Filling CO2 24 Nos 3,058 213101 73,392
545.26 Refilling of 75 kg ABC F/E -With 90% MAP Powder & Filling CO2 6 Nos 9,285 213039 55,710
545.27 Refilling of 2 kg ABC F/E -With 90% MAP Powder & Filling N2 8 Nos 546 213040 4,368
545.28 Refilling of 6 kg ABC F/E -With 90% MAP Powder & Filling N2 19 Nos 1,091 213041 20,729
545.29 Refilling of 9 kg ABC F/E -With 90% MAP Powder & Filling N2) 14 Nos 1,420 213102 19,880
545.30 Refilling of CO2 Gas Cartridge 200 Grams 45 Nos 142 210133 6,390
545.31 Refilling of CO2 Gas Cartridge 1.0 kg 45 Nos 427 210135 19,215
545.32 Refilling of CO2 Gas Cartridge 2.0 kg 45 Nos 427 210136 19,215
545.33 Refilling nitrogen for ABC F/E 2 kg(SP) 9 Nos 189 213043 1,701
545.34 Refilling nitrogen for ABC F/E 6 kg(SP) 17 Nos 236 212565 4,012
545.35 Refilling nitrogen for ABC F/E 9.0 kg(SP) 10 Nos 284 210518 2,840
545.36 Brass Operating CAP for DCP F/E 25 Nos 520 213204 13,000
545.37 Operating Cap with Safety Valve -DCP 14 Nos 995 501031 13,930
545.38 PVC Discharge Hose for 6 Kg ABC F/E 9 Nos 189 213103 1,701
545.39 PVC Discharge Hose for 9Kg ABC/DCP 20 Nos 236 501032 4,720
545.40 PVC Discharge Hose for 25.0Kg DCP/ABC (3 Mtr. Long) 35 Nos 520 501471 18,200
545.41 PVC Discharge Hose for 75Kg DCP/ABC (5 Mtr. Long) 17 Nos 805 501033 13,685
545.42 Spray Nozzle 6 kg. F/E ABC 9 Nos 75 213104 675
545.43 ABS Plastic Squez Grip Nozzle up to 9 kg DCP/ABC 27 Nos 142 213105 3,834
545.45 Brass Chromium Plated Safety Clip with chain 225 Nos 28 501472 6,300
545.46 Rubber Cap Washer - DCP 95 Nos 28 501037 2,660
545.47 RUBBER BUSH,SCREW & WASHER up to 9 KG - ABC 58 Nos 19 501038 1,102
545.48 Inner Container 9/25 Kg. -DCP 15 Nos 331 500295 4,965
545.49 Wall Brackate 2/5/6/9/10 Kg. - DCP 16 Nos 28 501810 448
545.50 Rubber Guard For Nozzle -DCP 21 Nos 9 501041 189
545.51 Pressure Gauge For 25/75 kg.- DCP 30 Nos 427 501811 12,810
545.52 Trolley Wheel -25 / 75Kg. -DCP 19 Nos 236 501812 4,484
545.53 Trolley Wheel Set - 25 / 75 Kg -DCP 12 Nos 1,184 501044 14,208
545.54 PVC sticker for F/E (DCP/ABC) showing Instruction of usage & applicability of FE 200 Nos 200 501821 40,000
545.55 Connecting Hose Between CO2 Pilot Cylinder up to 75KG 75 Nos 284 501475 21,300
545.56 Shutoff Nozzle for 25/75KgDCP F/E 24 Nos 1,089 501046 26,136
545.57 Spring loaded safety valve-DCP 29 Nos 427 501047 12,383
545.58 Dry Chemical Powder (Sodium Bi-carbonate) with ISI Mark 5Kg 30 Nos 42 501476 1,260
545.59 Dry Chemical Powder (90% MAP) with ISI Mark up to 5/6 Kg 40 Nos 75 501477 3,000
545.60 Pre Gauge:upto 2 kg ABC(Stored pre Type)F/E 9 Nos 142 501478 1,278
545.61 Pre Gauge: 6 kg ABC(Stored pre Type)F/E 7 Nos 142 501479 994
545.62 Pre Gauge: 9 kg ABC(Stored pre Type)F/E 7 Nos 142 501480 994
545.63 PVC discharge hose 6 kg ABC (SPT) F/E 9 Nos 142 212573 1,278
545.64 PVC discharge hose 9 kg ABC (SPT) F/E 11 Nos 189 213205 2,079
545.65 Discharge Brass Nozzle 6 kg ABC (SPT)F/E 7 Nos 95 501820 665
545.66 Discharge Brass Nozzle 9 kg ABC (SPT)F/E 7 Nos 95 501481 665
545.67 Plunger 6 kg ABC (Stored pre Type) F/E 7 Nos 331 212575 2,317
545.68 Plunger 9 kg ABC (Stored pre Type) F/E 9 Nos 331 501482 2,979
545.69 "O" ring for 2/6/9 kg ABC (SPT) F/E 15 Nos 19 501483 285
545.70 Brass Operating Cap Assembly-DCP 9Kg 11 Nos 1,089 501049 11,979
545.71 PVC Discharge Hose+Open Spray Nozzle-9kg 44 Nos 189 501050 8,316
545.72 ABS Plastic Siphon Tube-DCP up to 9Kg 31 Nos 118 501051 3,658
545.73 Locking Pin for ABC type up to 9kg 90 Nos 28 501056 2,520
545.74 Discharge Hose with Horn 1Mtr. for 4.5kg 9 Nos 402 501054 3,618
545.75 Discharge Hose with Horn 3Mtr. for 9.0kg 45 Nos 805 500273 36,225
545.76 Discharge Horn 4.5Kg 14 Nos 142 501055 1,988
545.77 Discharge Horn 9.0Kg 85 Nos 189 500275 16,065
545.78 Discharge Hose 4.5Kg 14 Nos 331 501070 4,634
545.79 Discharge Hose 9.0Kg 45 Nos 711 500277 31,995
545.80 Aluminium CO2 Locking Pin 125 Nos 9 500278 1,125
545.81 Locking Holder 150 Nos 47 501057 7,050
545.82 CO2 Neck Handle with Rubber Grip 40 Nos 142 501058 5,680
545.83 M.S. Heavy Duty Wall Bracket CO2 F/E 15 Nos 28 500311 420
545.84 Trolley Wheel - 9.0 Kg 35 Nos 236 501484 8,260
545.85 Trolley Wheel Set - 9.0 Kg 30 Nos 1,089 500313 32,670
545.86 Rubber Handle ( Hose Between Horn) CO2 45 Nos 19 500314 855
545.87 MS Nipple ( Hose Between Horn) CO2 45 Nos 19 501061 855
545.88 PVC sticker for F/E (CO2/ABC) showing Instruction of usage & applicability of FE 115 Nos 200 212919 23,000
545.89 Acrylic sheet tag checking&Maint. 220 Nos 200 212920 44,000
546 Supply of Items of First Aid Boxes 0
546.01 Supply & Replacement of Small Dressing Bandage for Finger Wound 154 Nos 65 212922 10,010
546.02 Supply & Replacement of Medium Dressing Bandage for Hands & Feet Wound 154 Nos 65 212923 10,010
546.03 Supply & Replacement of Absorbent cotton wool 87 Nos 42 212924 3,654
546.04 Supply & Replacement of Antiseptic Solution (Dettol/Savlon) - 60ml 87 Nos 43 102193 3,741
546.05 Supply & Replacement of Dressing Scissors 55 Nos 47 212925 2,585
546.06 Supply & Replacement of Roll of Adhesive Plaster 2cms x 1 Mtr. USP 67 Nos 48 212926 3,216
546.07 Supply & Replacement of Eye Pads 122 Nos 35 212927 4,270
546.08 Supply & Replacement of Polythene Wash Bottle/Eye Cup for washing eyes 60 Nos 23 212928 1,380
546.09 Supply & Replacement of Safety Pins of 215 Nos 9 212929 1,935
546.10 Supply & Replacement of Potassium Permanganate (Used for cleaning wounds and dermatitis, fungal infections) 72 Nos 53 212930 3,816
546.11 Supply & Replacement of Soframycin ointment (used for curing wounds, cuts, burns) 92 Nos 53 212931 4,876
546.12 Supply & Replacement of triangle bandage 72 Nos 37 212932 2,664
546.13 Supply & Replacement of Band Aid Strips 620 Nos 23 212933 14,260
546.14 Supply & Replacement of ORS 145 Nos 19 212934 2,755
546.15 Supply & Replacement of Pain Relief Spray 62 Nos 208 212935 12,896
546.16 Supply & Replacement of First Aid Box 52 Nos 805 212936 41,860
546.17 Supply & Replacement of Wind Sock Stand 25 Nos 1,305 212937 32,625
546.18 Supply & Replacement of Wind Sock 198 Nos 497 212938 98,406
547 Maintenance of SCBA set 0
547.01 Hydrotesting of SCBA cylinder 6 Nos 1,895 212941 11,370
547.02 Refilling of SCBA cylinder 6 Nos 946 501410 5,676
548 Supply of radium sticker with lamination as per instructed by EIC 35 sq ft 500 213543 17,500
549 Painting of Do's & Don’t's on wall 30 sq mtr 691 20,730
550 Supply of Fire Sand bucket confirming to IS 2546 15 No 2,000 30,000
551 Supply of stand for Fire sand bucket confirming to IS 2546 3 No 3,000 9,000
CIV-114 552 ANTI TERMITE / PEST CONTROL TREATMENT Providing, applying and spraying of ant termite chemicals over termite mounds, at column pits, walls, trenches and basement excavations, RCC framed structures and RCC walls, on top surface of plinth filling, junction of walls and floors, soil under apron and plinth protection, including providing approved chemicals, tools, plants, instruments, consumables and labour. The quantity shall be measured in square meter as per instruction of EIC(M) 3 sq mtr 2,500 102280 7,500
Total for One Year excluding GST 100,239,384
Total for Two Year excluding GST 200,478,768
Bidder to quote (-) % / Discount
Bidder to quote (+) % / Accreation
Bidded Total excluding GST 200,478,768
Note :- GST shall be at actual.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1.Rajkot.pdf
2.Rajkot-Region.pdf
3.Anjar-SubBase.pdf
4.Bhavnagar-Base.pdf
Annexure-1 Rajkot Base Pipeline details.xlsx
XLSX
Annexure-2 Details of Terminal Rajkot Base.xlsx
XLSX
Annexure-3 AMS.xlsx
XLSX
Detailed Scope of Work (Rev-01).pdf
GTL AVL-28.0.pdf
AMC RB Bidding Schedule rev-0.pdf
SOR AMC Rajkot and Bhavnagar Base Rev-0.xlsx
XLSX
RFP_Maintenance Contract for Rajkot and Bhavnagar Base_Tender.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .