| # | Company | Amount |
|---|---|---|
| 1 | ₹100 2 YOUR TEN DER SUBM ITTED ON 08 02 2023 ON E TEND ER WEBSITE 3 OUR CORRIGENDUM ADDENDUM 01 DATED 31 01 2023 4 OUR CORRI GENDUM ADDENDUM 02 DATED 18 02 2023 5 YOU R PRICE BID OPENED ON 18 02 2023 ON E TENDER WEBSITE | ₹100 |
Tender Value
₹7.5 Cr
EMD Value
₹7.5 L
Closing Date
20 Oct 2022, 11:00 amClosed
Renovation of Executive flat complex, Sec 4, boundary wall & development of Park under the work of Various Civil, Electrical, Water Supply, Horticulture, Hospitality jobs required for Hockey World Cup 2023 and other jobs in Steel Township at Rourkela Odisha
NBCC/SBG/RAN/2022/47
NBCC/SBG/RAN/2022/47
Open Tender-Domestic
Civil Works General
Sundargarh, Odisha
₹11,800
₹7.5 L
6 Aug 2026
6 Oct 2022
20 Oct 2022
20 Oct 2022
2 Nov 2022
D Total Amount i/c GST (DSR + Non-DSR):- 74,500,628
BILL OF QUANTITY
Renovation of Executive flat complex, Sec-4, boundary wall & development of Park under the work of Various Civil, Electrical, Water Supply, Horticulture, Hospitality jobs required for Hockey World Cup-2023
and other jobs in Steel Township at Rourkela (Odisha).
SL No DSR/MR ITEM DESCRIPTION Unit Qty RATE AMOUNT
1 2.8 Earth work in excavation by mechanical means (Hydraulic excavator) /
manual means in foundation trenches or drains (not exceeding 1.5 m
in width or 10 sqm on plan), including dressing of sides and ramming
of bottoms, lift upto 1.5 m, including getting out the excavated soil and
disposal of surplus excavated soil as directed, within a lead of 50 m.
2.8.1 All kinds of soil Cum 696.00 302.22 210343.01
2 2.25 Filling available excavated earth (excluding rock) in trenches, plinth,
sides of foundations etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead up
to 50 m and lift upto 1.5 m.
3 1.0 CARRIAGE OF MATERIAL
1.1 By Mechanical Transport including loading, unloading and stacking
4 MR-1 Supplying and filling in plinth with sand under floors, including
watering, ramming, consolidating and dressing complete.
5 4.1 Providing and laying in position cement concrete of specified grade
excluding the cost of centering and shuttering - All work up to plinth
4.1.8 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources
: 8 graded stone aggregate 40 mm nominal size derived from natural Cum 84.00 6664.95 559855.43
6 4.1 Providing and laying in position cement concrete of specified grade
excluding the cost of centering and shuttering - All work up to plinth
4.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources
: 4 graded stone aggregate 20 mm nominal size derived from natural Cum 10.00 7759.71 77597.12
7 5.1 Providing and laying in position specified grade of reinforced cement
concrete, excluding the cost of centering, shuttering, finishing and
reinforcement - All work up to plinth level :
5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural
sources : 3 graded stone aggregate 20 mm nominal size derived from Cum 176.00 8812.28 1550961.66
natural sources)
8 5.2 Reinforced cement concrete work in walls (any thickness), including
attached pilasters, buttresses, plinth and string courses, fillets,
columns, pillars, piers, abutments, posts and struts etc. above plinth
level up to floor five level, excluding cost of centering, shuttering,
finishing and reinforcement :
5.2.1 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural
sources : 3 graded stone aggregate 20 mm nominal size derived from Cum 59.00 10730.68 633109.98
natural sources).
5.9 Centering and shuttering including strutting, propping etc. and removal
9 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete Sqm 1267.00 324.45 411074.76
10 5.9.3 Suspended floors, roofs, landings, balconies and access
11 5.9.4 Shelves (Cast in situ) Sqm 1.00 807.62 807.62
12 5.9.5 Lintels, beams, plinth beams, girders, bressumers and
13 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts Sqm 450.00 847.33 381300.67
14 5.22/ Steel reinforcement for R.C.C. work including straightening, cutting,
5.22A bending, placing in position and binding all complete upto plinth level./
Steel reinforcement for R.C.C. work including straightening, cutting,
bending, placing in position and binding all complete above plinth level
5.22.6/ Thermo-Mechanically Treated bars of grade Fe-500D or more.
15 6.36 Brick work with modular extruded brunt fly ash clay sewer bricks
(Conforming to IS: 4885 ) in cement mortar 1:4 (1 cement : 4 Coarse
sand) in foundation and plinth :
6.36.1 Cement Mortar 1:4 ( 1 cement : 4 coarse sand) Cum 10.00 6878.45 68784.52
16 6.32 Brick work with clay flyash F.P.S. (non modular) brick of class
designation 7.5 in superstructure above plinth level up to floor five
6.32.2 Cement mortar 1:6 (1 cement : 6 coarse sand) Cum 287.00 8629.70 2476723.39
17 13.4 12 mm cement plaster of mix :
18 13.6 20 mm cement plaster of mix :
19 13.87 White washing with lime to give an even shade :
13.87.1 Old work (two or more coats) Sqm 1000.00 20.02 20017.86
BILL OF QUANTITY
Renovation of Executive flat complex, Sec-4, boundary wall & development of Park under the work of Various Civil, Electrical, Water Supply, Horticulture, Hospitality jobs required for Hockey World Cup-2023
and other jobs in Steel Township at Rourkela (Odisha).
SL No DSR/MR ITEM DESCRIPTION Unit Qty RATE AMOUNT
20 13.43 Applying one coat of water thinnable cement primer of approved
brand and manufacture on wall surface :
13.43.1 Water thinnable cement primer Sqm 4000.00 67.90 271610.71
21 13.48A Finishing walls with 100% Premium acrylic emulsion paint having VOC
less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali &
fungal resistance, dirt resistance exterior paint of required shade
(Company Depot Tinted) with silicon additives
13.48A.1 New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and
including priming coat of exterior primer applied @ 0.90 litre/10 sqm. Sqm 4000.00 162.72 650896.43
22 13.50 Applying priming coat:
13.50.1 With ready mixed pink or Grey primer of approved brand and
manufacture on wood work (hard and soft wood)
23 13.61 Painting with synthetic enamel paint of approved brand and
manufacture to give an even shade :
13.61.1 Two or more coats on new work Sqm 98.00 138.49 13572.21
24 10.2 Structural steel work riveted, bolted or welded in built up sections,
trusses and framed work, including cutting, hoisting, fixing in position
and applying a priming coat of approved steel primer all complete.
25 15.7 Demolishing brick work manually/ by mechanical means including
stacking of serviceable material and disposal of unserviceable material
within 50 metres lead as per direction of Engineer-in-charge.
15.7.4 In cement mortar Cum 10.00 1789.44 17894.38
26 15.2 Demolishing cement concrete manually/ by mechanical means
including disposal of material within 50 metres lead as per direction of
Engineer - in - charge.
15.2.2 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) Cum 10.00 1306.01 13060.07
27 15.3 Demolishing R.C.C. work manually/ by mechanical means including
stacking of steel bars and disposal of unserviceable material within 50 Cum 10.00 3084.96 30849.63
metres lead as per direction of Engineer - in- charge.
28 2.8 Earth work in excavation by mechanical means (Hydraulic excavator) /
manual means in foundation trenches or drains (not exceeding 1.5 m
in width or 10 sqm on plan), including dressing of sides and ramming
of bottoms, lift upto 1.5 m, including getting out the excavated soil and
disposal of surplus excavated soil as directed, within a lead of 50 m.
29 2.25 Filling available excavated earth (excluding rock) in trenches, plinth,
sides of foundations etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead up
to 50 m and lift upto 1.5 m.
30 MR-1 Supplying and filling in plinth with sand under floors, including
watering, ramming, consolidating and dressing complete.
31 1.1 By Mechanical Transport including loading,unloading and stacking
32 6.36 Brick work with modular extruded brunt fly ash clay sewer bricks
(Conforming to IS: 4885 ) in cement mortar 1:4 (1 cement : 4 Coarse
sand) in foundation and plinth :
6.36.1 Cement Mortar 1:4 ( 1 cement : 4 coarse sand) Cum 65.00 6878.45 447099.37
33 6.32 Brick work with clay flyash F.P.S. (non modular) brick of class
designation 7.5 in superstructure above plinth level up to floor five
6.32.2 Cement mortar 1:6 (1 cement : 6 coarse sand) Cum 104.00 8629.70 897488.61
34 6.45 Half brick masonry with non modular fly ash bricks of class designation
10, conformingio IS :12894, in super structure above plinth and upto
6.45.2 Cement mortar 1 : 4 (1 cement : 4 coarse sand) Sqm 244.00 1021.60 249269.31
35 4.1 Providing and laying in position cement concrete of specified grade
excluding the cost of centering and shuttering - All work up to plinth
4.1.8 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources
: 8 graded stone aggregate 40 mm nominal size derived from natural Cum 314.00 6664.95 2092792.90
36 4.1 Providing and laying in position cement concrete of specified grade
excluding the cost of centering and shuttering - All work up to plinth
4.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources
: 4 graded stone aggregate 20 mm nominal size derived from natural Cum 255.00 7759.71 1978726.46
BILL OF QUANTITY
Renovation of Executive flat complex, Sec-4, boundary wall & development of Park under the work of Various Civil, Electrical, Water Supply, Horticulture, Hospitality jobs required for Hockey World Cup-2023
and other jobs in Steel Township at Rourkela (Odisha).
SL No DSR/MR ITEM DESCRIPTION Unit Qty RATE AMOUNT
37 5.1 Providing and laying in position specified grade of reinforced cement
concrete, excluding the cost of centering, shuttering, finishing and
reinforcement - All work up to plinth level :
5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural
sources : 3 graded stone aggregate 20 mm nominal size derived from Cum 10.00 8812.28 88122.82
natural sources)
38 5.2 Reinforced cement concrete work in walls (any thickness), including
attached pilasters, buttresses, plinth and string courses, fillets,
columns, pillars, piers, abutments, posts and struts etc. above plinth
level up to floor five level, excluding cost of centering, shuttering,
finishing and reinforcement :
5.2.1 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural
sources : 3 graded stone aggregate 20 mm nominal size derived from Cum 10.00 10730.68 107306.78
natural sources).
5.9 Centering and shuttering including strutting, propping etc. and removal
39 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete Sqm 22.00 324.45 7137.84
40 5.9.2 Walls (any thickness) including attached pilasters, butteresses, plinth
and string courses etc.
41 5.9.3 Suspended floors, roofs, landings, balconies and access
42 5.9.4 Shelves (Cast in situ) Sqm 1.00 807.62 807.62
43 5.9.5 Lintels, beams, plinth beams, girders, bressumers and
44 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts Sqm 13.00 847.33 11015.35
45 5.22/5.22A Steel reinforcement for R.C.C. work including straightening, cutting,
bending, placing in position and binding all complete upto plinth level./
Steel reinforcement for R.C.C. work including straightening, cutting,
bending, placing in position and binding all complete above plinth level
5.22.6/5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. Kg 1668.00 94.45 157547.07
46 22.5 Providing and laying water proofing treatment in sunken portion of
WCs, bathroom etc., by applying cement slurry mixed with water
proofing cement compound consisting of applying :
a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water
proofing cement compound @ 0.253 kg/ sqm. This layer will be
allowed to air cure for 4 hours.
(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water Sqm 100 544.28 54427.50
proofing cement compound @ 0.126 kg/sqm. This layer will be
allowed to air cure for 4 hours followed with water curing for 48 hours.
The rate includes preparation of surface, treatment and sealing of all
joints, corners, junctions of pipes and masonry with polymer mixed
47 MR-71 Cleaning the surface by chipping of lose materials etc. and provide
two coat of Sika Topseal 107(Two pack acrylic cementitious water
proofing coating system) with glass fiber on the surface (3kg per sqm Sqm 823.00 343.72 282879.21
for two coats) or equivalent and as per direction of Engg-In-Charge.
Water proofing treatment of RCC sunshade with Zycosil/equivalent
water proofing Solution (1 litre of Zycosil/equivalent & 20 litres of
water stirred first & 2 litres of Zycoprime/equivalent added and stirred
(total 23 litres)) till it meets the saturation level and testing as per
RILEM or by water drops test in which water drops do not absorb but
drops remain or rolls.
49 14.75 Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5
sqm and under, including cutting the patch in proper shape, raking out
joints and preparing plastering the wall surface with white cement
based polymer modified self curing mortar, including disposal of
rubbish, all complete as per the direction of Engineer-In-Charge.
50 MR Providing damp proof elastomeric coating on wall/roof surface for
water proofing with Asian Smart care/ Sika XT/ Choksey futura 5 with
primer and min two coats of elastomeric paint as per manufacturer
specification along with cleaning, scrapping and surface preparation
including cost of all materials, labours, tools and tackles, lead, lift etc
complete as per direction of the Engineer-in-charge
51 MR-52 Providing & mixing chemical admixture such as "SIKA LATEX" or
equivalent in cement concrete / mortar and bonding work as per
manufacturer's specification and as directed by Engineer- in - Charge.
52 17.35 Providing and fixing soil, waste and vent pipes :
BILL OF QUANTITY
Renovation of Executive flat complex, Sec-4, boundary wall & development of Park under the work of Various Civil, Electrical, Water Supply, Horticulture, Hospitality jobs required for Hockey World Cup-2023
and other jobs in Steel Township at Rourkela (Odisha).
SL No DSR/MR ITEM DESCRIPTION Unit Qty RATE AMOUNT
17.35.1.2 Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989
53 17.60 Providing and fixing trap of self cleansing design with screwed down or
hinged grating with or without vent arm complete, including cost of
cutting and making good the walls and floors :
17.60.1 100 mm inlet and 100 mm outlet
17.60.1.1 Sand cast iron S&S as per IS: 3989 Each 108.00 1690.03 182523.66
54 17.38 Providing and fixing bend of required degree with access door,
insertion rubber washer 3 mm thick, bolts and nuts complete.
17.38.1.2 Sand cast iron S&S as per IS - 3989 Each 217.00 629.61 136626.30
55 17.39 Providing and fixing plain bend of required degree.
17.39.1.2 Sand cast iron S&S as per IS - 3989 Each 108.00 463.31 50037.27
56 17.43 Providing and fixing single equal plain junction of required degree with
access door, insertion rubber washer 3 mm thick, bolts and nuts
17.43.1.2 Sand cast iron S&S as per IS - 3989 Each 108.00 770.58 83222.87
57 MR-65 To fill the peripheral gap between pipe and concrete/brick surface
with free flow, ready to use, Sika Rep Microcrete 4 of Sika or
equivalent of Fosroc,Pidilite,BASF and sealing the mouth of annual gap
in 10 mm x 10 mm with moisture insensitive, two component, epoxy
based Sikagard 694 FI of Sika or equivalent of Fosroc,Pidilite,BASF as
58 14.72 Providing and fixing double scaffolding system (cup lock type) on the
exterior side, up to seven story height made with 40 mm dia M.S. tube
1.5 m centre to centre, horizontal & vertical tubes joining with cup &
lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S.
staircase system in the scaffolding for working platform etc. and
maintaining it in a serviceable condition for the required duration as
approved and removing it there after .The scaffolding system shall be
stiffened with bracings, runners, connection with the building etc
wherever required for inspection of work at required locations with
essential safety features for the workmen etc. complete as per
directions and approval of Engineer in-charge .The elevational area of
the scaffolding shall be measured for payment purpose .The payment
will be made once irrespective of duration of scaffolding. sqm 285.00
Note: - This item to be used for maintenance work judicially, necessary
deduction for scaffolding in the existing item to be done.
59 15.56 Dismantling old plaster or skirting raking out joints and cleaning the
surface for plaster including disposal of rubbish to the dumping ground Sqm 1706.00 47.46 80972.55
within 50 metres lead.
60 13.4 12 mm cement plaster of mix :
61 13.6 20 mm cement plaster of mix :
62 13.16 6 mm cement plaster of mix :
63 13.91 Removing dry or oil bound distemper, water proofing cement paint
and the like by scrapping, sand papering and preparing the surface Sqm 3579.00 21.97 78619.77
smooth including necessary repairs to scratches etc. complete.
64 13.88 Removing white or colour wash by scrapping and sand papering and
preparing the surface smooth including necessary repairs to scratches Sqm 3000.00 17.23 51677.68
65 13.43 Applying one coat of water thinnable cement primer of approved
brand and manufacture on wall surface :
13.43.1 Water thinnable cement primer Sqm 3868.00 67.90 262647.56
66 13.80 Providing and applying white cement based putty of average thickness
1 mm, of approved brand and manufacturer, over the plastered wall
surface to prepare the surface even and smooth complete.
67 13.48A Finishing walls with 100% Premium acrylic emulsion paint having VOC
less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali &
fungal resistance, dirt resistance exterior paint of required shade
(Company Depot Tinted) with silicon additives.
13.48A.1 New work (Two or more coats applied @ 1.43 litre/ 10 sqm. Over and
including priming coat of exterior primer applied @ 0.90 litre/10 sqm Sqm 7158.00 162.72 1164779.16
68 13.50 Applying priming coat:
BILL OF QUANTITY
Renovation of Executive flat complex, Sec-4, boundary wall & development of Park under the work of Various Civil, Electrical, Water Supply, Horticulture, Hospitality jobs required for Hockey World Cup-2023
and other jobs in Steel Township at Rourkela (Odisha).
SL No DSR/MR ITEM DESCRIPTION Unit Qty RATE AMOUNT
13.50.1 With ready mixed pink or Grey primer of approved brand and
manufacture on wood work (hard and soft wood)
69 13.61 Painting with synthetic enamel paint of approved brand and
manufacture to give an even shade :
13.61.1 Two or more coats on new work Sqm 532.00 138.49 73677.73
70 12.50 Providing and fixing precoated galvanised iron profile sheets (size,
shape and pitch of corrugation as approved by Engineer-in-charge)
0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams
per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy
primer on both side of the sheet and polyester top coat 15-18 microns.
Sheet should have protective guard film of 25 microns minimum to
avoid scratches during transportation and should be supplied in single Sqm 219.00 707.53 154948.17
length upto 12 metre or as desired by Engineer in-charge. The sheet
shall be fixed using self drilling /self tapping screws of size (5.5x 55
mm) with EPDM seal, complete upto any pitch in horizontal/ vertical
or curved surfaces, excluding the cost of purlins, rafters and trusses
and including cutting to size and shape wherever required.
18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply including all CPVC
plain & brass threaded fittings This includes jointing of pipes & fittings
with one step CPVC solvent cement, trenching, refilling & testing of
joints complete as per direction of Engineer in Charge
73 15.7 Demolishing brick work manually/ by mechanical means including
stacking of serviceable material and disposal of unserviceable material
within 50 metres lead as per direction of Engineer-in-charge.
15.7.4 In cement mortar Cum 72.00 1789.44 128839.56
74 15.2 Demolishing cement concrete manually/ by mechanical means
including disposal of material within 50 metres lead as per direction of
Engineer - in - charge.
15.2.2 Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) Cum 18.00 1306.01 23508.13
75 15.18 Dismantling steel work in built up sections in angles, tees, flats and
channels including all gusset plates, bolts, nuts, cutting rivets, welding
etc. including dismembering and stacking within 50 metres lead.
76 15.1 Demolishing lime concrete manually/ by mechanical means and
disposal of material within 50 metres lead as per direction of Cum 9.00 739.55 6655.99
Engineerin- charge.
77 15.3 Demolishing R.C.C. work manually/ by mechanical means including
stacking of steel bars and disposal of unserviceable material within 50 Cum 9.00 3084.96 27764.66
metres lead as per direction of Engineer - in- charge.
78 14.79 Disconnecting damaged overhead/terrace PVC water storage tank of
any size from water supply line and removing from the terrace
including shifting at ground level as per direction of Engineer-in-charge
79 10.28 Providing and fixing stainless steel ( Grade 304) railing made of Hollow
tubes, channels, plates etc., including welding, grinding, buffing,
polishing and making curvature (wherever required) and fitting the
same with necessary stainless steel nuts and bolts complete, i/c fixing
the railing with necessary accessories & stainless steel dash fasteners ,
stainless steel bolts etc., of required size, on the top of the floor or the
side of waist slab with suitable arrangement as per approval of
Engineer-in charge, (for payment purpose only weight of stainless
steel members shall be considered excluding fixing accessories such as
nuts, bolts, fasteners etc.).
80 MR-3 Fabricating and erecting structural steel like joist/ channel/ angle in
trusses/ posts/ rafter/ purlins in true to line and level including cutting
required length. drilling holes and welding etc complete as per the Kg 1464.00 40.50 59290.95
direction of the Engr-In-charge. (Excluding cost of structural steel).
81 MR-66 Supplying and spreading of moorum / Stone Crusher dust at the work
site as per the instruction of site engineer in charge
82 11.39 Providing and laying rectified Glazed Ceramic floor tiles of size
300x300mm or more (thickness to be specified by the manufacturer),
of 1st quality conforming to IS : 15622, of approved make, in colours
White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement Sqm 7.00 1204.02 8428.15
mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry
@ 3.3 kg/ sqm including grouting the joints with white cement and
matching pigments etc., complete.
BILL OF QUANTITY
Renovation of Executive flat complex, Sec-4, boundary wall & development of Park under the work of Various Civil, Electrical, Water Supply, Horticulture, Hospitality jobs required for Hockey World Cup-2023
and other jobs in Steel Township at Rourkela (Odisha).
SL No DSR/MR ITEM DESCRIPTION Unit Qty RATE AMOUNT
83 8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to
IS: 15622 (thickness to be specified by the manufacturer), of approved
make, in all colours, shades except burgundy, bottle green, black of
any size as approved by Engineer-in-Charge, in skirting, risers of steps
and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3
coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,
including pointing in white cement mixed with pigment of matching
shade complete.
84 11.41A Providing and laying Vitrified tiles in floor in different sizes (thickness
to be specified by the manufacturer) with water absorption less than
0.08% and conforming to IS:15622, of approved brand &
manufacturer, in all colours and shade, laid on 20 mm thick cement
mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry
@3.3 kg/sqm including grouting the joints with white cement and
matching pigments etc. The tiles must be cut with the zero chipping
diamond cutter only . Laying of tiles will be done with the notch
trowel, plier, wedge, clips of required thickness, leveling system and
rubber mallet for placing the tiles gently and easily.
11.41A.3 Glazed Vitrified tiles Matt/Antiskid finish of size
85 16.68 Providing and laying 60mm thick faciory made cement concrete
interlocking paver block of M -30 grade made by block making
machine with strong vibratory compaction, of approved size, design &
shape, laid in required colour and pattern over and including 50mm Sqm 153.00 1001.95 153297.80
thick compacted bed of coarse sand, filling the joints with line sand
etc. all complete as per the direction of Engineer-in-charge.
86 11.56 Providing and laying Polished Granite stone flooring in required design
and patterns, in linear as well as curvilinear portions of the building all
complete as per the architectural drawings with 18 mm thick stone
slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement
: 4 coarse sand) laid and jointed with cement slurry and pointing with
white cement slurry admixed with pigment of matching shade
including rubbing, curing and polishing etc. all complete as specified
and as directed by the Engineer-in-Charge
11.56.1 Polished Granite stone slab colour of Black, Cherry/Ruby Red or
87 16.90 Providing and laying tactile tile (for vision impaired persons as per
standards) of size 300x300x9.8mm having with water absorption less
than 0.5% and conforming to IS:15622 of approved make in all colours
and shades in for outdoor floors such as footpath, court yard, multi
modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 Sqm 153.00 1811.09 277096.66
cement : 4 coarse sand) in all shapes & patterns including grouting the
joints with white cement mixed with matching pigments etc. complete
as per direction of Engineer-in-Charge.
88 13.18 Neat cement punning. Sqm 70.00 71.43 5000.25
89 16.17 Fencing with R.C.C. post placed at required distance, embedded in
cement concrete blocks, every 15th post, last but one end post and
corner post shall be strutted on both sides and end post one side only,
provided with horizontal lines and two diagonals of barbed wire
weighing 9.38 kg per 100 metres (minimum), between the two posts
fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire
tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts,
struts, earth work and concrete to be paid for separately) :- Payment
to be made per metre cost of total length of barbed wire used.
16.17.1 Providing and fixing of barbed wire of thickest barb two ply, four
points @4" c/c for fencing with the existing R.C.C./angle iron/wooden
fence posts true to line and as per the direction of the Engr-In-charge.
90 16.70 Providing and fixing G.I. chain link fabric fencing of required width in
mesh size 50x50 mm including strengthening with 2 mm dia wire or
nuts, bolts and washers as required complete as per the direction of
Engineer-in-charge.
16.70.1 Made of G.I. wire of dia 4 mm Sqm 1703.00 905.54 1542142.53
BILL OF QUANTITY
Renovation of Executive flat complex, Sec-4, boundary wall & development of Park under the work of Various Civil, Electrical, Water Supply, Horticulture, Hospitality jobs required for Hockey World Cup-2023
and other jobs in Steel Township at Rourkela (Odisha).
SL No DSR/MR ITEM DESCRIPTION Unit Qty RATE AMOUNT
91 MR-49 Lettering sign board/ display board/ border/ symbol etc. with single or
multi colour fluorescent sticker in any language ( hindi, odiya,english)
on a prepared base /surface. the measurement will be paid as per the
length/width of sentence/symbol/border and height of stickers with
complete all lead & lift as per instruction of engr.-in-charge. where
there will be difference of height of letters in sentence, the height of
small letter shall be considered for measurement.
92 21.1 Providing and fixing aluminium work for doors, windows, ventilators
and partitions with extruded built up standard tubular sections/
appropriate Z sections and other sections of approved make
conforming to IS: 733 and IS: 1285, fixing with dash fasteners of
required dia and size, including necessary filling up the gaps at
junctions, i.e. at top, bottom and sides with required EPDM rubber/
neoprene gasket etc. Aluminium sections shall be smooth, rust free,
straight, mitred and jointed mechanically wherever required including
cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass /
stainless steel screws, all complete as per architectural drawings and
the directions of Engineer-in-charge. (Glazing, paneling and dash
fasteners to be paid for separately) :
21.1.1 For fixed portion
21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50
93 21.1.2 For shutters of doors, windows & ventilators including providing and
fixing hinges/ pivots and making provision for fixing of fittings
wherever required including the cost of EPDM rubber / neoprene
gasket required (Fittings shall be paid for separately)
21.1.2.2 Powder coated aluminium (minimum thickness of powder coating 50
94 21.2 Providing and fixing 12 mm thick prelaminated particle board flat
pressed three layer or graded wood particle board conforming to IS:
12823 Grade l Type ll, in panelling fixed in aluminum doors, windows
shutters and partition frames with C.P. brass / stainless steel screws
etc. complete as per architectural drawings and directions of
engineer in-charge.
21.2.2 Pre-laminated particle board with decorative lamination on both sides
95 21.3 Providing and fixing glazing in aluminium door, window, ventilator
shutters and partitions etc. with EPDM rubber / neoprene gasket etc.
complete as per the architectural drawings and the directions of
engineer-in-charge . (Cost of aluminium snap beading shall be paid in
21.3.2 With float glass panes of 5 mm thickness (weight not less than 12.50
Total Amount (Civil) (A):- 36,721,980 1,421,830
Total Amount (Civil) (A):- 36,721,980 1,421,830
DSR 2022 ELECTRICAL
Supplying and fixing following rating, double pole, 240 V,
isolator in the existing MCB DB complete with connections,
testing and commissioning etc. as required
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C"
curve, miniature circuit breaker suitable for inductive load of
2 2.10 following poles in the existing MCB DB complete with
connections, testing and commissioning etc. as required
2.10.2 Single pole and neutral Each 530 631.09 334477.32
Supply and fixing of 240/415V, AC Make: Standard Electricals Limited/
3 MR Indo-Asian/ L&T/Havels /schneide. ‘C’ Series/ Curve single pole with Each 100 2212.50 221250.00
Wiring for circuit/ submain wiring alongwith earth wire with the
4 1.7 following sizes of FRLS PVC insulated copper conductor, single core
cable in surface/ recessed steel conduit as required.
BILL OF QUANTITY
Renovation of Executive flat complex, Sec-4, boundary wall & development of Park under the work of Various Civil, Electrical, Water Supply, Horticulture, Hospitality jobs required for Hockey World Cup-2023
and other jobs in Steel Township at Rourkela (Odisha).
SL No DSR/MR ITEM DESCRIPTION Unit Qty RATE AMOUNT
Supply and laying of 25 mm(1") dia.of thickness 1.5mm tough PVC
pipe with ISI marked (make: Berlia Electricals Polymers/Poly Cab/
Prestige Plastics or any other make approved by the Deptt.)
6 MR concealed on wall/ ceiling/structure with proper saddling 14 SWG Mtr 16000 116.95 1871142.86
Al.ECC and other accessories on wall/ceiling surface with necessory
connections etc.complete as required including masonry work to its
Supplying and fixing following size/ modules, GI box alongwith
7 1.27 modular base & cover plate for modular switches in recess etc.
Supply & fixing of 1x16w/20W , LED T/L Fitting (Philips/Bajaj/GE/CG/
C&S/MESCAB/Lighting Technology) with mounting channel,bi-pin
8 MR holder & tube on existing wooden board/round block Each 900 479.38 431437.50
with necessary connections.
Supply & Fixing of bakelite angle holder/pendent holder/batten holder
on the existing wooden board/round block/bakelite sheet with all
connection complete as required. (ANCHOR make holders are to be
Supply & fixing of down rod for ceiling fan upto 3 feet whereever
required as per direction of Executive-in-charge
Supply & fixing of flexible Twin Cu.wire 16/020 mm size for
11 MR buzzer/calling bell/tube light/fan Mtr 3500 65.32 228625.00
etc.connection.
Supply & fixing of backelite ceiling rose on existing wooden round
12 MR block/ wooden board/bakelite Each 500 77.96 38982.14
sheet including all connection complete as required.
Supply & laying of 19 mm (3/4") dia.of thickness 1.5mm tough PVC
pipe with ISI marked (make: Berlia Electricals Polymers/Poly Cab/
Prestige Plastics & any other make approved by the Deptt.) with
proper saddling and other accessories such as RJ, Round Sheet and
PVC Bend on wall/ceiling surface with necessory connections
etc.complete as required including masonry work to its original.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre
below ground as strip earth electrode, including connection/
terminating with G.I. nut, bolt, spring, washer etc. as required.
(Jointing shall be done by overlapping and with 2 sets of G.I. nut
bolt & spring washer spaced at 50mm)
Supplying and fixing following modular switch/ socket on the
15 1.24 existing modular plate & switch box including connections but
excluding modular plate etc. as required.
1.24.4 3 pin 5/6 A socket outlet Each 900 128.54 115682.14
1.24.5 6 pin 15/16 A socket outlet Each 150 207.55 31133.04
Supplying and fixing modular blanking plate on the existing modular
plate & switch box excluding modular plate as
required.(make:LEGRAND,ANCHOR,L&T,SIEMENS,HAVELS,ABB,SCHNEI
Providing, laying and fixing following dia G.I. pipe (medium
class) in ground complete with G.I. fittings including trenching
(75 cm deep)and re-filling etc as required
SUPPLY & FIXING OF 50MMX6MM MS DOUBLE CLAMP SET FORFIXING
ALONG RCC POST/TUBLER POST WITH 12MM DIA GI BOLT & NUT AS
Installation of exhaust fan in the existing opening, including
19 1.50 making good the damage, connection, testing, commissioning
etc. as required.
BILL OF QUANTITY
Renovation of Executive flat complex, Sec-4, boundary wall & development of Park under the work of Various Civil, Electrical, Water Supply, Horticulture, Hospitality jobs required for Hockey World Cup-2023
and other jobs in Steel Township at Rourkela (Odisha).
SL No DSR/MR ITEM DESCRIPTION Unit Qty RATE AMOUNT
Supply&fixing of ceiling fan 48"sweep including all
necessaryconnections for proper functioning of
fans.(make:usha/orient/khaitan)
Supplying and fixing two module stepped type electronic fan
regulator on the existing modular plate switch box including
connections but excluding modular plate etc. as required.
Supplying and fixing following rating, four pole, (three phase
and neutral), 415 volts, residual current circuit breaker (RCCB),
22 2.15 having a sensitivity current 30 mA in the existing MCB DB
complete with connections, testing and commissioning etc. as
Supply of 240/415V, AC 50Hz Miniature Circuit Breaker Isolator,
capacity & no. of poles as mentioned or as per the direction of
Engineer in-charge. Make: Standard Electricals Limited,
Indo-Asian, L&T, Hagger, Siemens.(c)Four pole 100A.
Supplying and fixing following way, single pole and neutral,
sheet steel, MCB distribution board, 240 V, on surface/ recess,
complete with tinned copper bus bar, neutral bus bar, earth
bar, din bar, interconnections, powder painted including
earthing etc. as required. (But without MCB/RCCB/Isolator)
Dismantling & transportation to store of assorted size cable upto 16
25 MR sq.mm (SC/TC/3C) on or Mtr 5000 31.61 158035.71
PUNCHING OF THE ROAD SUITABLE FOR LAYING UP TO 4" DIAMETER
Removal of existing defective ceiling fan/cabin fan with or without
27 MR regulator from the residential Qrs/other premises and transportation Each 240 347.68 83442.86
& deposit at Elect. Maint. Stores
Supply and Fixing of 70 to 250A TP contactor including time clock
inside the panel board/wall surface including making holes in the
M.S sheet with supply and fixing of required nut and bolts including
all connections.
Supplying and fixing MOTOR STARTER-25A on the existing modular
plate switch box including connections but excluding modular plate
required(make:C&S,ANCHOR,L&T,SIEMENS,HAVELS,ABB,SCHNEIDER)
Excavation of new cable trench of 1.5 feet deep & 1 feet width in all
kinds of soil (including cutting of cement concrete, pitch road, rail line
crossing, wet soil, hard & rocky soil etc.) & back filling to the reqd.
30 MR extent. (wihout brick and sand) including supply & laying HDPE pipe, Mtr 250 653.74 163435.27
the HDPE pipe shall confirm to P-63 grade, dia 50mm, wall thickness
more than 4mm with ISI mark as per direction of Engineer-in-charge.
Supply and laying of cable 4 x 25mm2 al. The cable 1100v grade shall
confirm to is:1554(part-1) with standard aluminum conductor
confirming to class-2 of is:8130/84. The cable shall be with armour of
galvanised round wire/flat steel strip. Cable shall confirm to the is
indicated with its latest amendment. Cable shall be with ISI
certification mark. Cable shall be laid in existing trench
Excavation of NEW cable trench of 1000mm deep & 500mm width in
all kinds of soil (including cutting of cement concrete, pitch road, rail
line crossing, wet soil, hard & rocky soil etc.), laying of required
quantity of side PCC slab (1:1.5:3) (1 cement: 1.5 sand: 3 graded stone
aggregate 20 mm nominal size) having size: 500mm(L) x 200mm(W) x
100mm(T) in the both side of cable and Top RCC slab (1:1.5:3) (1
cement: 1.5 sand: 3 graded stone aggregate 20 mm nominal size)
having size: 500mm(L) x 300mm (W) x 50mm(T), sand etc. & back
filling to the required extent as per standard practice. All the materials
required are to be arranged by the contractor.
BILL OF QUANTITY
Renovation of Executive flat complex, Sec-4, boundary wall & development of Park under the work of Various Civil, Electrical, Water Supply, Horticulture, Hospitality jobs required for Hockey World Cup-2023
and other jobs in Steel Township at Rourkela (Odisha).
SL No DSR/MR ITEM DESCRIPTION Unit Qty RATE AMOUNT
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick
including accessories, and providing masonry enclosure with
33 5.4 cover plate having locking arrangement and watering pipe of each 20 7872.29 157445.71
2.7 metre long etc. with charcoal/ coke and salt as required.
Supply and fixing of fabricated feeder pillar ofsize 850mm(h) x
500mm(l) x 400mm (w) made out of 2mm thick ms sheet with front
opening two doors( for housing cable and termination kit kat
fuse/catridge fuse base of size- 0 & size-1, neutral bus and 2 nos.
stud bolts for earth connection) fabricated on ms angle
structure/frame of size 850mm +300mm (h) x 500mm (l) x 400mm (w)
made out of 50x50x6mm ms angle(300mm exetended for legs).the
34 MR feeder pillar should have dust and water ingress protection each 5 341351.88 1706759.38
conforming to ip:54. the feeder pillar should be duly spray painted
on both inner and outer side with one coat of red oxide primer & 2
coats of alminium paint. feeder pillar to be fixed at site with
concreting 4 nos of exetended legs. fitting & fixtures required for
feeder pillar against for feeder piller are as follows.( drawing to be
collected if required )
SUPPLY AND FIXING OF COOL WHITE 60 W LED STREET
LIGHTFITTING.LUMINARIES TYPE :LED, POWER RATED 60W, VOLTAGE
RATED:240V AC 50HZ, PF>0.9.HERMETICALLY SEALED, LED EFFICIENCY
>90LM/W, FOR STREET LIGHT FITTINGS HAVING PRESSURE DIE-CAST
ALUMINUM HOUSING & FRAME, MANUFACTURE WORD MARK/NAME
ENGRAVED/EMBOSSING ON THE DIE -CAST HOUSING,HEAT RESISTANT
TOUGHENED GLASS/POLY CARBONATE COVER WITH IP66 PROTECTION
OF (MAKE: PHILIPS/BAJAJ/GE/CG/SYSKA/MESCAB/LIGHTING
Supply and fixing of ICTPN/MCTPN 100 Amp.Main switch 440v
of make JJ-Delux/HELCON / HAVEL S/ ELMECK or, any other suitable
make with ISI marked approved by the Deptt. on the existing M.S
36 MR frame or wall surface on wooden board including all connection Each 15 10250.20 153752.95
complete as required with cable end sockts.All contacts and carrying
screws should be made out of electrolytic copper/brass.
Supply and fixing of Recessed Mounting cool white/warm
white LED fitting (Philips/Bajaj/GE/CG/C and S/MESCAB/Lighting
37 MR Technology) of 30w with suppy voltage 100V - 265 V,50HZ, Pre- Each 60 2181.95 130916.79
treated CRCA frame in Powder coated white finish,LED Efficacy: >90
lm/W, Weather protection: IP 20
Supply & fixing of 38mm dia heavy gauge GI pipe bracket of 2mtr
length on the pole surface with necessary clamping arrangement
for LED/MV/SV fitting with necessary cold bending as per site
39 MR viii) Bell push Each 80 128.54 10282.86
Dismantling of the existing damaged battens separating the wiring
with ECC and rewiring with new superior quality PVC CASHING and
CAPING with proper fixing on the ceiling/wall /structural surface with
necessary connection etc.complete as required. PVC CASHING and
CAPING to be supplied by party. 1/2" size PVC cashing and caping
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
1 NIT-47.pdf
Tender Document
SCC.pdf
Tender Document
3 BOQ_.pdf
Tender Document
4 GCC WITH AMMENDMENTS 01 TO 17.pdf
Tender Document
5 List of Approved Make.pdf
Tender Document
6 Phy Milestone.pdf
Tender Document
7 IP.pdf
Tender Document
8 SCOPE OF WORK.pdf
Tender Document
Amendment 18.pdf
Tender Document
corrigendum-1102-CORRI 02 NIT-47.pdf
pdf • 0.40 MB
corrigendum-1062-Corri-1 NIT 47.pdf
pdf • 1.54 MB
addendum-10f4517360bc-Amendment no 18.pdf
pdf • 1.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .