| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.8 LAccepted-AOC | ₹13.8 L Quoted ₹14.2 L | L1 | Accepted-AOC L1 BIDDER |
| 2 | L2₹14.2 L+₹1,840.50 (0.13%)Rejected-AOC | ₹14.2 L+₹1,840.50 (0.13%) | L2 | Rejected-AOC OTHER THAN L1 |
| 3 | L3₹15.5 L+₹1.3 L (9.16%)Rejected-AOC | ₹15.5 L+₹1.3 L (9.16%) | L3 | Rejected-AOC OTHER THAN L1 |
| 4 | L4₹16.5 L+₹2.3 L (16.2%)Rejected-AOC | ₹16.5 L+₹2.3 L (16.2%) | L4 | Rejected-AOC OTHER THAN L1 |
| 5 | L5₹16.8 L+₹2.6 L (18.1%)Rejected-AOC YOL CAMP TEH DHARAMSHALA DISTT KANGRA HP | YOL | KANGRA | HIMACHAL PRADESH | 176052 | ₹16.8 L+₹2.6 L (18.1%) | L5 | Rejected-AOC OTHER THAN L1 |
Tender Value
₹15.5 L
EMD Value
₹31,000
Closing Date
31 May 2021, 6:00 pmClosed
CWE YOL CANTT
HQ CWE YOL CANTT
SPECIAL REPAIR TO BUILDING NO P-9 IN LSNS AREA UNDER GE (KH) YOL
2021_MES_439439_1
CWE/Y-04/2021-22
Open Tender
Civil Works
Item Rate
180 days
YOL Cantt
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
GE (KH) Yol
₹31,000
Yes
5 Aug 2021
30 Apr 2021
1 Jun 2021
30 Apr 2021
31 May 2021
17 May 2021
Amount
Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15 cm thick above or below ground level complete and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed.
Taking down cement plaster including backing etc from brick/stone walls / concrete surfaces including raking out joints, hacking for key , scrubbing down with water etc complete all as specified and directed
Taking down and removing chowkats with shutters (without taking off shutters from chowkat) not exceeding 1.50 Sqm each complete all as specified and directed.
Taking down and removing chowkats with shutters (without taking off shutters from chowkat) exc 1.50 Sqm but not exc 4.00 Sqm each complete all as specified and directed. .
Taking down steel water tubing 15 mm bore including all fitting and connections complete all as specified and directed.
Taking down steel water tubing 20 mm bore including all fitting and connections complete all as specified and directed.
Taking down steel water tubing 25 mm bore including all fitting and connections complete all as specified and directed.
Dismantling timber scantling as in fillets, rails, rafter etc under 40 sqcm in section framed work complete all as specified and directed.
Dismantling timber in scantling 40 sqcm and over in section framed work complete all as specified and directed.
Demolition of wall and ceiling boards any thickness including cover fillets complete all as specified and directed.
Demolition and breaking up 100mm bore drain pipe (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed.
Demolition and breaking up 75mm bore drain pipe (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed.
Dismantling plain or corrugated steel sheets any gauge thickness including Nanital or similar pattern roof covering including ridges complete all as specified and directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubish off the premises. complete all as specified and as directed.
Hard core of broken stone or boulders of gauge not exc 63 mm deposited ,spread and leveled in layer not exc 15 cm thick complete all as specified and directed.
PCC 1:4:8 (nominal mix) type D-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed.
Plain cement concrete 1:2:4 ( nominal mix ) type B-0 (using 12.5 mm graded crushed stone aggregates) as in roof kerbs or mud stops, or in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating chamfered on edges including necessary formwork where required complete all as specified and directed.
Brick work with old size fly ash bricks, class 7.5, straight or curved on plan exc. 6 metre mean radius built in cement mortar 1:6 all as specified & directed.
Factory made solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain coloured PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening complete all as specified and directed.
Factory made solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet and edges shall be painted to match with prelam sheet reinforced with M.S. Square tube, suppling & fixing in opening complete all as specified and directed.
35mm thick second class hardwood (Sal/Hollock) factory made plain framed panelled shutter (two panel) with lock rails & panel of 9 mm B.W.P commercial ply wood or 12 mm thick veneered particle board with commercial veneering on both side. The size of rail and stile as per IS:1003 (Part-I) kiln seasoned and chemically pressure treated complete all as specified and directed.
25 mm thick flush shutters, solid core construction with particle board core and plywood face panels commercial type on both sides including 6mm thick external teak wood lipping complete all as specified and directed.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of 5 mm thick plain coloured PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site, Sheet No 1/1) specified and directed.
Factory made fully glazed PVC window/ventilator shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail complete all as specified and directed.
Small fittings of 2nd class hard wood (Sal/Hollock)) such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary' labours; articles n exc 200 cu. cm each complete all as specified and directed.
Steel window 1.25mm thick box type (Primer coated) ERW hollow P section of size 85mm x 35mm double rebated comprises gauged, glazed skelton shutter ERW Sec 50mm x 20mm and 1mm thick with two openable leaf consiting two Nos sash bar of T-Section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T-section of size 30mm x 25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC M-15, type B-0 (04 No's for each window, steel duly painted with one shop coat of zinc chromate primer on prepared surfaces) and finishing the surfaces to match with existing including following fitting welded to frame shutter:- (i) Hold fast, 150mm long of 12mm x 3mm made to shape -04 Nos per window. (ii) Handle of Z section 20mm x 25mm, 100mm long -1 No per leaf. (iii) MS tower bolt 150mm long - 2 No per leaf (iv) Z section 20mm x25mm, 100 long stopper - 1 No per leaf. (v) Cleat 65mm long of hollow square 15mm x 20mm x 63mm welded to hinge -1 No per leaf. (vi) Mild steel pintle hinge of size 75mm x 12mm - 2 Nos per leaf. (vii) Flat iron fillets of size 20X3 mm for fixing wire gauge. (viii) Fabrication & fixing arrangement as per drg No. CEPZ/ TD 06/07. Make : As per Appendix 'C'. Note:-(i) Above referred drawing has not been made part of tender. The same can be seen in the office of GE during working hours on any working day.
Framed work such as grills, gratings etc with ends of bars shouldered and/or riveted or forged into spikes framed guard bars including cutting, drilling, welding etc confirming to Fe-290 Gde E-165 all as specified and directed.
250 mm long aluminium alloy, anodized, sliding door bolt with hasp, staple(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed.
Aluminium handles cast type anodized of size 75 mm complete all as specified and directed.
Aluminium handles cast type anodized of size 100 mm complete all as specified and directed.
Aluminium handles cast type anodized of size 150 mm complete all as specified and directed.
Aluminium anodized barrel tower bolt of extruded section of size 100 mm and fixed complete all as specified and directed.
Aluminium anodized barrel tower bolt of extruded section of size 150 mm and fixed complete all as specified and directed.
Brass continuous (piano) hinges, bright finish or electrogalvanised of width flaps size 30 mm (when open) complete all as specified and directed.
Floor door stopper of 140 mm long of brass body and tongue, anodized with hard drawn steel spring, fixed in floor complete all as specified and directed.
Mild steel butt hinges of size 100 mm medium weight cold rolled complete all as specified and directed.
Mild steel butt hinges of size 50 mm medium weight cold rolled complete all as specified and directed.
Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or stainless steel wire staples complete all as specified and directed.
300 mm long mild steel ordinary rat tail rod pattern spring including roller and roller plate complete .
Sheet glass, 4 mm thick ordinary quality and glazing with oil putty in squares n.exc 0.5 sqm each pane complete all as specified and directed.
4 mm thick non asbestos fibre cement building boards as in ceiling fixed or laid/ inserted to timber/ GI/ aluminium frame work fixed with nails, all as specified.
Prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.60mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified, all as specified and directed.
1.6mm thick mild steel plain black sheet in wall cladding ,steel gates and similar works ,cut to size ,holes punched, including round headed screws, clout nails or rivets and fixed to steel framing with plain 40mm lap joints with riveted or welded seams including bending or turning up, mitred angles etc as required all as specified and directed.
Rolled mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to grade Fe 410 -W (Gde-E- 250) quality-A, complete all as specified and as directed.
Mild steel work as in tublar trusses including specail shaped washer etc, complete using ERW orinduction butt welded tubes conforming to Is-1661-1979 grade St-240, complete all as specified and as directed.
Rolled mild steel sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc conforming to grade Fe.290.Gde-E-165 complete all as specified and as directed.
Rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to grade Fe.410.Gde-E-250 A, complete all as specified and as directed.
Mild steel work as in hold fast, wind ties for roof including securing bolts including all necessary drilling ,bolting or reverting etc and all similar work conforming to Fe-290 (Gde E-165) complete all as specified and directed.
Expeanded metal , cut in lemgth , bent to required shape, weight of member not exc. 4 kg / sqm , fixed to steel member complete all as specified and as directed.
25 mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregates) as in floor finish, surface finished even and fair to receive top finish complete all as specified and directed.
75mm thick PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregates) as in sub base complete all as specified and directed.
75 mm thick PCC 1:2:4 type B-2 (using 40 mm graded crushed stone aggregates) as in floor finish, surface finished even and fair complete all as specified and directed.
Mat finish, premium quality, joint free (edge cut), coloured/ printed ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, as in floors etc. set and jointed in neat cement slurry and including 15mm thick bedding layer in cement mortar (1:6) including necessary cutting and waste as per site requirement pointed in white or coloured cement to match complete all as specified and directed.
Mat finish, premium quality, joint free (edge cut), coloured/ printed ceramic tiles 10 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm,as in skirting , dados ,vertical surfaces etc , set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tile over and including 10 mm thick cement screed in cement mortar 1:3 including necessary cutting and waste as per site requirement pointed in white or coloured cement to match complete all as specified and directed.
Glazed ceramic coloured tiles of size 450 mm x 350 mm x 7 mm/350 mm x 250 mm x 7 mm thick as in vertical surfaces , set and jointed in neat cement slurry and pointed with white or coloured cement to match the shade of tile over and including 10 mm thick cement screed in cement mortar 1:3 complete all as specified and directed. Size/Shade/Colour of tile shall be approved by the GE.
Vitrified ceramic tiles (light shade) 10mm thick (square/rectangular) polished, area of each tile not exceeding 0.18 sqm but not exc 0.38 sqm as directed by EIC, as in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
20mm thick Granite work (table rubbed and polished) incills steps, jambs, cooking plate forms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified & directed.
20mm thick Granite (Single piece) work (table rubbed and polished) in shelves of cup boards and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, complete all as specified & directed.
Machine cut kota stone slab flooring 18-20 mm thick of size not less than 550 mm X 550 mm as per sample kept in GE’s office, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab, as in floor etc, laid over and including 15mm screed layer in cement mortar 1:4 (1 cement : 4 coarse sand), cutting, rubbing, grinding and polishing to achieve mirror finish, laid over PCC subbase complete, all as specified.
Machine cut kota stone slab flooring 18-20 mm thick SINGLE PIECE FOR TREADS OF STEPS), laid and jointed with grey cement slurry mixed with pigment to match the shade of slab, as in floor etc, laid over and including 15mm screed layer in cement mortar 1:4 (1 cement : 4 coarse sand), cutting, rubbing, grinding and polishing to achieve mirror finish, laid over PCC subbase complete, all as specified.
Machine cut kota stone slab flooring with white boarder lining 18-20 mm thick as per sample kept in GE’s office, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab,as in in skirting, dados, risers to steps etc, laid over and including 10mm thick rendering in cement mortar 1:4 (1 cement : 4 coarse sand), cutting, rubbing, grinding and polishing to achieve mirror finish complete, all as specified.
Machine cut kota stone slab flooring 18-20 mm thick SINGLE PIECE FOR RISERS OF STEPS), laid and jointed with grey cement slurry mixed with pigment to match the shade of slab, as in floor etc, laid over and including 10mm thick rendering in cement mortar 1:4 (1 cement : 4 coarse sand), cutting, rubbing, grinding and polishing to achieve mirror finish, laid over PCC subbase complete, all as specified.
Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade with grey cement and pigment laid over and including 50mm thick sand cushioning, joints of tiles filled with dry sand and compacted with mechanical vibrator over and including 75mm thick PCC M-10 (Nominal Mix) type C-2, using 40mm graded crushed stone aggregate complete all as specified and directed.
Plain cement concrete 1:3:6, type C-1, using 20mm graded mechanically crushed stone aggregate, 50mm thick as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen VG-10 and two parts of heated coarse sand (by volume), all as specified. Note:- The unit rate include for use of form work (straight or curved).
Rendering cement plaster 15mm thick in cement mortar 1:4 in two layers on other than fair faces of brick wall or on stone masonry surfaces, mixed with water proofing admixture as per manufacturer's instructions, trowelled to even and smooth finish without using extra cement complete all as specified. (Note:- WPC will be measured and paid separately)
Rendering cement plaster 15mm thick in cement mortar 1:4 on stone masonry or surface other than fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified.
Rendering cement plaster 15mm thick in cement mortar 1:6 on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified.
Supply only liquid water proofing admixture.
Preparation of steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Preparation of wooden surfaces of any description and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of walls and applying two coats of oil emulsion distemper over a coat of primer over and including 3mm thick wall care putty (applied in two layers), finished smooth with sand paper complete all as specified and directed.
Preparation of old surfaces of wall by Complete removal of existing treatment and applying two coats of oil bound distemper over a coat of primer over and including 2mm thick wall care putty (applied in two layers), finished smooth with sand paper complete all as specified and directed.
Two coats of white wash on newly plastered or un plastered, previously undecorated walls surfaces including preparation of surfaces complete, all as specified.
Preparation of newly plastered or un plastered, previously undecorated wall surfaces and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed.
Preparation of newly plastered or un plastered, previously undecorated wall surfaces and applying two coats of exterior emulsion paint (weather proof paint) over and including 2mm thick wall care putty (applied in two layers), finished smooth with sand paper complete all as specified and directed.
Preparation of old surfaces of wall by Complete removal of existing treatment and applying two coats of exterior emulsion paint (weather proof paint) over and including 2mm thick wall care putty (applied in two layers), finished smooth with sand paper complete all as specified and directed.
Two coats of oil emulsion distemper on newly plastered or un plastered, previously undecorated ceiling surfaces including preparation of surfaces complete, all as specified.
Preparation of new plastered surfaces or un plastered, previously undecorated wall surfaces and applying two coats of cement base paint, complete all as specified and directed.
G I tubing medium grade of 15 mm bore with all fittings and fixtures fixed to wall and ceiling or laid in floor/trenches complete all as specified and directed.
All as per ser item No 40 above but except pipe including new fittings as per requirement .
G I tubing medium grade of 20 mm bore with all fittings and fixtures fixed to wall and ceiling or laid in floor /trenches complete all as specified and directed.
All as per ser item No 40 above but except pipe including new fittings as per requirement .
G I tubing medium grade of 25 mm bore with all fittings and fixtures fixed to wall and ceiling or laid in floor /trenches complete all as specified and directed.
Stainless steel curtain rod, 25 mm bore, powder coated with all fittings i.e. wall bracket, bracket screws, stope and rollers, fixed in repairs all as specified.
Brass chromium plated tubular towel rail 20 mm dia, "D" type, 60 cms long between flanges fixed in repairs with and including chromium plated brass brackets, brass screws complete all as specified
Chromium plated soap dish, fixed in repair complete all as specified.
15mm bore, chromium plated, centre hole mixer half turn complete, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts,fixed in repair complete all as specified.
Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
Chromium plated shower roses with or without swivel joints, 125mm size, including fixing to steel pipe or union complete all as specified
Table top wash basin, Vitreous China , size 180mm x 455mm x 455mm, crystal white with and including supply & fixing on 20mm thick,black granite of size 500mm x 750mm, cut to shape , chamfered to finish edge paste with same granite rounded to match, inside cut to fix basin with grooove providing fitting to wall with iron brackets complete, 450 mm long PVC connections 15mm size with PTMT coupling nuts at both ends, trap, grating and Union for discharge pipe, waste, chain and plug and porcelain stopper, waste pipe of polythylene of low or high density or PVC of 32mm dia including Pillar taps, 15mm bore cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, 32mm dia waste fittings, brass chromium plated with long screwed shanks and fly nuts, flange and bedded in red lead cement and other end fixed, screwed for iron pipe and fixed, complete all as specified. Make: Cat Part No. JDS-WHT-0543 of Jaquar or equivalent in makes mentioned in Appx
Stop valves/ angle valve/ concealed valve, cast copper alloy, chromium plated, fancy type, screwed down, high pressure , screwed both ends for 15mm bore iron pipe or for unions and fixed in repairs complete, all as specified. Type of valve approved by the GE.
Stop valves cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions for 20mm bore iron pipe or for unions and fixed in repairs complete, all as specified.
Bib tap, cast copper alloy ,chromium plated, fancy type , screwed for iron pipe or for brass ferrule of 15 mm bore and fixed in repairs complete all as specified and directed.
Health faucet (ABS body with 1m long easy flex in chrome finish tube and wall hook complete with accessories, fixed in repair, complete all as specified.
Vitreous China wash down water closet (pedestal pattern), white including traps, connection to drain or outgoing pipe, flushing pipe, anti-syphonage pipe complete including fittings, PVC white seat cover and chromium plated jet including PVC connection, fixed complete including demolition of old unservicable WC and provision of plain cement concrete M-15, type B-I, using 20mm graded crushed stone aggregate, fixed in repairs all as specified. Make: Cat Part No. 2008 for EWC, 2308 for seat cover, 2201/B for internal fittings of 'Cera' or equivalent in makes mentioned in Appx 'C'
PVC valve less, crystal white, syphonic action type flushing cistern 10 litre capacity, superior quality, plunger type, low level, with inlet, ball valve, float and handle, 32 mm dia PVC long bend flush pipe 90cm long and 15 mm dia 600 mm long PVC connection with CP brass coupling nuts and PVC washers at both ends fixed, in repairs, all as specified. Make: Cat Part No. 2602 of Cera or equivalent in makes mentioned in Appx 'C'.
600x450 mm bevelled edge mirror of slected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plug with chromium plated brass screwed and cup washers.
110mm dia PVC(SWR) pipe single socketed with rubber ring joints, laid/fixed to tranches or in floor or walls ,fixed in repair omplete all as specified and directed.
75mm dia PVC(SWR) pipe single socketed with rubber ring joints, laid/fixed to tranches or in floor or walls, fixed in repair complete all as specified and directed.
110 mm dia PVC(SWR) bend, any radius complete all as specified and directed.
75 mm dia PVC(SWR) bend, any radius complete all as specified and directed.
110mm dia PVC (SWR) junction single, (single T) equal or unequal provided with oval access door complete all as specified and directed.
75 mm dia PVC(SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
75 mm dia PVC(SWR) vent cowl complete all as specified and directed.
Taking down point wiring with aluminium/ copper conductor for light point, socket point/ power point etc. in PVC casing and caping, surface pvc/ steel conduits, wood batten with clips including taking down board any type and size complete with any type of switches, sockets, holders, (batten or pendent type), ceiling rose etc. The light fittings (any type), main switches, distribution board with MCB’s of any capacity and make are to be removed/ replaced if required and all as specified and directed. NOTE: - Existing fan regulator any type (Where required) and electric meters are to be refixed and connected properly where required.
Taking down sheet metal enclosure DB, MCB, main switch etc and making good distrubed surfaces to match with existing surface complete all as specified and directed.
Point wiring with 1.5 Sqmm copper conductor FRLS (Multistrand) PVC insulated ISI Marked unsheathed cable in and including PVC conduit not less than 20mm dia, medium grade with IS 9537 (Part-III) 1983 marking with all fittings/ accessories as specified in preamble 1 (a) to (q) of Section 19 of SSR Part-II, under heading point wiring and also including PVC insulated ISI marked unsheathed 1.5 Sqmm copper multistranded conductor FLRS as earth wire (green colour) connected to common earth dolly and including pressed steel terminal boxes made out of 1.20 mm thick mild steel sheet duly painted with one coat of red oxide primer for mounting of switches, sockets, fan regulators, light fittings etc. covered with 3mm thick plastic laminated sheet (ISI marked) for one light point or one fan point or one fan point through regulator or one bell point, controlled by one way switch/ push button complete including making good disturbed surfaces to match with existing all as specified and directed.
All as per serial item No '107' above, but for one 3 pin 5 Amps socket outlet on the same board all as specified and directed.
All as per serial item No '107' above, but for one 3 pin 5 Amps socket outlet, independent all as specified and directed.
All as per serial item No '107' above, but for one light point controlled by two way switch all as specified and directed.
All as per serial item No. '107' above but for 3 pin 15 Amps socket out let independent with 2.5 Sqmm PVC copper conductor cable and and PVC insulated, unsheathed 2.5 Sqmm stranded copper conductor cable as continuous earth wire, all as specified.
All as per serial item No. '107' above but for 3 pin 15 Amps socket out let independent with 4 Sqmm PVC copper conductor cable and and PVC insulated, unsheathed 4 Sqmm stranded copper conductor cable as continuous earth wire, all as specified.
Sheet metal enclosure with 4 modules , flush type with 20 Amps AC starter & 20 Amps socket, DB , MCB & 25 Amps plug top with indicator complete all as specified.
Switch piano flush type, single pole, one way, 5 Amps, all as specified.
Switch piano flush type, single pole, two way, 5 Amps, all as specified and directed.
Switch socket combination two in one, 5 amps flush type, all as specified.
Switch socket combination two in one, 3 Pin 5 amps and 15 amps, flush type, all as specified.
Bell push, flush type, 5 amp all as specified.
Bell, AC,ding dong, 230 volts, single pole all as specified.
Ceiling rose, 65 mm to 50 mm, two to three terminals, PVC/ Polycarbonate, insulated body fixed on PVC block, all as specified.
Flush type, step fan speed controller suitable for 1200/ 1400 mm sweep ceiling fan complete all as specified and directed.
Taking down electric meter of any size and capacity, refixing the same after rewiring , complete all as directed.
Taking down ceiling/ exhaust fan of 1200/ 1400/ 250/ 300 mm sweep from fan hook dismentling blade opening of motor cleaning stator rotor, cleaning of all parts, greasing, oiling of bush & bearing, reassembling including replaecement of unserviceable parts complete, refixing, reconnecting with 3 core copper cable of size 23/0.0076 from ceiling rose to ceiling fan and testing on completion, complete all as specified.
Removal of existing burnt winding of ceiling fan, cleaning the slots thoroughly with suitable cleaning agent, applying slot insulation and rewinding with new super enameled insulated 30 to 38 SWG copper wire of appropriate size including all winding, insulating material and impregnation of insulating varnish of any make, type, model, applying air drying the winding thoroughly complete, all as specified and directed.
Disconnecting/ taking down electric water heater any type/ capacity 25 litre, removing and cleaning the dust properly, painting with two coats of synthetic enamel paint of same colour using spray gun after preparing surface for painting including refixing duly grouting nuts, bolts, washers and making plumbing connections and making the conections with 3 core copper flexible cable of size 23 x .0076 from ceiling rose/ PVC connector to light and testing complete all as specified.
Renewal of sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 12 way, double door, 240 volts with 200 Amp rated bus bar, all as specified.
Renewal of sub main wiring with two single core PVC insulated cable 1100 volts grade with copper stranded RLS conductor of size 6 Sqmm (2 single run) with one continuous FRLS copper earthing lead wire of size 6 Sqmm and drawn into PVC conduit/ casing & capping with all fittings/ accessories, junction boxes 1 to 4 way 20mm dia, cutting chases, making good in cement mortar (1:3), finishing surfaces to match with existing and connected to common earth dolly including taking down old unservicable submain wiring, complete and as directed. Note :- Two run (each run of 1 RM) of 6 sqmm copper conductor and one RM of earth wire of 6 Sqmm, shall be measured as one RM).
E-lite LED Triyca batten, colour changing LED batten with options of 3000K, 4000K & 6500K all in one fixture, 20 Watts complete with all accessories and fixtures prewired and making connection with 3 core copper flexible cable of size 23 x .0076 from ceiling rose/ PVC connector to light complete. Make : Havell's Cat Part No. LHEXBYPNIN1W020 or equivalent in makes mentioned in Appx 'C'.
E-lite LED Triyca batten, colour changing LED batten with options of 3000K, 4000K & 6500K all in one fixture, 10 Watts complete with all accessories and fixtures prewired and making connection with 3 core copper flexible cable of size 23 x .0076 from ceiling rose/ PVC connector to light complete. Make : Havell's Cat Part No. LHEXBYPNIN1W010 or equivalent in makes as per PS.
Roadway lighting luminaire, LED street light 35 watts, IP-66 having aluminium housing with toughned glass on 9.00 metres poles/ walls. LED should be mounted on MCPCB and should be fixed to the body with proper thermal conductive paste to ensure quick heat transfer of heat to heat sink. This ensure the LED assembly free from dust/ moisture/ water entry (IP-66). The operating voltage should be from 90V to 300V with under voltage and over voltage protection. The luminaire should be connected aluminium pvc insulated wire 2 sqmm as required at site and connecting the same to the cable with the help of the connector all as specfied and directed. Make:- Havell's Cat Part No ENDURACITYLITEPLAT PLUSSL35W LED757SASYBOPC or equivalent in makes mentioned in Appendix 'C'. Note:- Contractor shall provide following certificates:- (i) IP-66 as per IS/ IEC60529-2001 with test certificate. (ii) THD˂15% with test certificate. (iii) Warranty upto two years.
Sheet metal encloser, vertical type DBs when MCCBs / MCBs used (MCCB for incomer and MCB for outgoing) TPN 4 way double door , 415 volts with 200 Amp rated bus bar having IP-43 protection including blanking plate, lugs etc complete, including making connections, fixing flushed to walls, nessary grauting, and making good to disturbed surfcae using CM (1;4) and finishing surface with matching to existing all as specified and as directed.
MCB TPN 40 to 63 Amps, 415 Volts, 10 KA all as specified.
MCB SPN 40 Amp, 240 Volts, 10 KA all as specified.
MCB SP 6 to 40 Amp, 240 Volts, 10 KA all as specified.
Excavation in trenches for pipes, cables and manholes in any type of soil n.exc 1.5m wide and but exc 1.5m deep and getting out complete all as specified and directed.
Returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any type of soil complete all as specified and directed.
Removal of excavated material (soil) to a distance n.exc 50 metres and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Sand cushioning to under ground cables provided with a layer of sand 8 cms thick before laying the cable and 15 cms thick after laying the cable complete all as specified and directed.
Sub class "B" bricks for covering to cable laid dry flat, with width equal to length of bricks all as specified and directed.
GI pipe light grade of size 40 mm dia laid in trenches/ walls including clamps, screws etc, complete all as specified and directed.
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multi-standard aluminium conductor, 1100 volts grade, cross sectional area 35 Sqmm 4 core, laid in trenches or passing through pipes, including making necessary connections at both ends, complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC (1:2:4), type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC M-15, type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
KISHAN CONTRACTOR
jatindera enterprises
VIJAY KUMAR LAKHNI
M/S AMOLAK SINGH AND SONS
Niraj Kumar and Co
MM Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .