Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 LAdmitted-Finance | ₹1.8 L | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | ARK Electricals L1 |
|---|---|---|---|---|
| 1.00details | ||||
| 1.01 | Laying of underground cable armoured/uunarmoured as per specification in air with approved type of iron clamps complete. 2/3/4 core cable upto 16 Sq.mm | 1 | प्रति मीटर | 45 ₹45 |
| 2.01 | Laying of underground cable armoured/uunarmoured as per specification in air with approved type of iron clamps complete. 3.5/4 core cable 25Sq.mm to 120 Sq.mm | 1 | प्रति मीटर | 65 ₹65 |
| 3.01 | SUPPLYING & laying of 4 Sq.mm 2 core Copper Cable Unarmouned | 1 | प्रति मीटर | 80 ₹80 |
| 4.01 | SUPPLYING & laying of 2.5 Sq.mm 3 core Copper Cable Unarmouned | 1 | प्रति मीटर | 65 ₹65 |
| 5.01 | SUPPLYING & laying of 1.5 Sq.mm 3 core Copper Cable Unarmouned | 1 | प्रति मीटर | 90 ₹90 |
| 6.01 | SUPPLYING & laying of 1 Sq.mm 3 core Copper Cable Unarmouned | 1 | प्रति मीटर | 100 ₹100 |
| 7.01 | SUPPLYING 4 Sq.mm 3 core Copper Cable Unarmouned | 1 | प्रति मीटर | 150 ₹150 |
| 8.01 | Dismantling of H beam pole in meter | 1 | प्रति मीटर | 550 ₹550 |
| 9.01 | Dismantling of PCC pole in meter | 1 | प्रति मीटर | 400 ₹400 |
Tender Value
Refer Docs
EMD Value
₹1.4 L
Closing Date
24 Dec 2025, 6:00 pmClosed
Incharge Officer
A.B. Road Nagar Palik Nigam Dewas
Tender for operation/maintenance of electrical work of Municipal Corporation owned buildings and external areas
2025_UAD_465781_1
165/electric/2025 dewas date 03.12.2025
Open Tender
Miscellaneous Services
365 days
Dewas
Please refer Tender documents.
7 documents required · 7 mandatory
₹5,000
Yes
₹1.4 L
Yes
27 Jan 2026
3 Dec 2025
26 Dec 2025
3 Dec 2025
24 Dec 2025
3 Dec 2025
Laying of underground cable armoured/uunarmoured as per specification in air with approved type of iron clamps complete. 2/3/4 core cable upto 16 Sq.mm
Laying of underground cable armoured/uunarmoured as per specification in air with approved type of iron clamps complete. 3.5/4 core cable 25Sq.mm to 120 Sq.mm
SUPPLYING & laying of 4 Sq.mm 2 core Copper Cable Unarmouned
SUPPLYING & laying of 2.5 Sq.mm 3 core Copper Cable Unarmouned
SUPPLYING & laying of 1.5 Sq.mm 3 core Copper Cable Unarmouned
SUPPLYING & laying of 1 Sq.mm 3 core Copper Cable Unarmouned
SUPPLYING 4 Sq.mm 3 core Copper Cable Unarmouned
Dismantling of H beam pole in meter
Dismantling of PCC pole in meter
Dismantling of R.S joist pole in meter
Relocation (One place to another place) of H beam pole in meter
Relocation (One place to another place) of PCC pole in meter
Relocation (One place to another place) of R.S joist pole in meter
Arm/angle/channel baseplate welding on pole
Arm/angle/channel baseplate Nut bolt
Supply and erection of ring or required shape for mini mast for required no. of flood light
Supply and installation of tubelar pole in meter
Supply and installation of arm in meter of pole for street light
M20 foundation for any type of pole with required Nut bolt
Earthing of G.I. Plate with charcoal etc complete
earthing of copper plate with charcoal etc complete
chemical earthing complete
supply and laying of G.I. Wire conductor earth electrod 4.0 mm (8.S.W.G.) dia G.I. Wire complete
supply and laying of G.I. Strip 25x6 mm
Laying rigid PVC single socket end, non-metallic pipe ISI Marked (IS-4985-2000) class 5 for protection of under ground cable/or for water pump delivery side, for water supply complete with necessary clamp coupler,band, tee, Elbow etc. in an approved manner excluding cost of excavation etc laying of different size of pipe.
Erection of pole direct in a ground with required material, RCC/PCC
Iron oxide paint colour with labour
All oxide paint colour with labour
Other paint colour as required with color (yellow, Black,Blue etc.)
Any wattage of LED flood light installation labour
Any wattage of LED Street light installation labour
Fan repairing including of relavant IS Standard required material
Timer repairing including material (Contractor, switch, MCB etc.)
cooler repairing including material
Main switch repairing including material
short point wiring in existing on surface including wire and other material
Medium point wiring in existing on surface including wire and other material
Long point wiring in existing on surface including wire and other material
short point wiring in existing in conduit including wire and other material
Medium point wiring in existing in conduit including wire and other material
Long point wiring in existing in conduit including wire and other material
power wiring as per in existing 2 x 4 sq.mm on surface with cable and casing & caping including required material
power wiring as per in existing 2 x 6 sq.mm on surface cable and casing & caping including required material
power wiring as per in existing 2 x 8 sq.mm on surface cable and casing & caping including required material
power wiring as per in existing 3 x 4 sq.mm on surface cable and casing & caping including required material
power wiring as per in existing 3 x 6 sq.mm on surface cable and casing & caping including required material
power wiring as per in existing 3 x 8 sq.mm on surface cable and casing & caping including required material
power wiring as per in existing 2 x 4 sq.mm in conduit including required material
power wiring as per in existing 2 x 6 sq.mm in conduit including required material
power wiring as per in existing 2 x 8 sq.mm in conduit including required material
power wiring as per in existing 3 x 4 sq.mm in conduit including required material
power wiring as per in existing 3 x 6 sq.mm in conduit including required material
power wiring as per in existing 3 x 8 sq.mm in conduit including required material
Circuit wiring in existing 2 x 2.5 sq mm on surface including required material
Circuit wiring in existing 2 x 1.5 sq mm on surface including required material
Circuit wiring in existing 2x 1.00 sq mm on surface including required material
Circuit wiring in existing 3 x 2.5 sq mm on surface including required material
Circuit wiring in existing 3x 1.5 sq mm on surface including required material
Circuit wiring in existing 3 x 1.00 sq mm on surface including required material
Circuit wiring in existing 2 x 2.5 sq mm in conduit including required material
Circuit wiring in existing 2 x 1.5 sq mm in conduit including required material
Circuit wiring in existing 2x 1.00 sq mm in conduit including required material
Circuit wiring in existing 3 x 2.5 sq mm in conduit including required material
Circuit wiring in existing 3x 1.5 sq mm in conduit including required material
Circuit wiring in existing 3 x 1.00 sq mm in conduit including required material
control pannel repairing including material
Water Cooler repairing including material
Ro repairing including material
All type of Speaker repairing including material
All type of mixer repairing including material
All type of Audio Amplifier including material
LED Light Repairing including Glass, PCB, Driver and other required material 30 w
LED Light Repairing including Glass, PCB, Driver and other required material 48 w
LED Light Repairing including Glass, PCB, Driver and other required material 60 w
LED Light Repairing including Glass, PCB, Driver and other required material 90 w
LED Light Repairing including Glass, PCB, Driver and other required material 120 w
LED Light Repairing including Glass, PCB, Driver and other material required 150 w
LED Light Repairing including Glass, PCB, Driver and other required material 200 w
LED Flood Light Repairing including Glass, PCB, Driver and other required material 30 w
LED Flood Light Repairing including Glass, PCB, Driver and other required material 48 w
LED Flood Light Repairing including Glass, PCB, Driver and other required material 60 w
LED Flood Light Repairing including Glass, PCB, Driver and other required material 90 w
LED Flood Light Repairing including Glass, PCB, Driver and other required material 120 w
LED Flood Light Repairing including Glass, PCB, Driver and other required material 150 w
LED Flood Light Repairing including Glass, PCB, Driver and other required material 200 w
LED Flood Light Repairing including Glass, PCB, Driver and other required material 250 w
LED Flood Light Repairing including Glass, PCB, Driver and other required material 300 w
LED Flood Light Repairing including Glass, PCB, Driver and other required material 400 w
supplu and Installation MCB Box 4 way (4+12) including required material
supplu and Installation MCB Box 4 way (8+12) including required material
supplu and Installation MCB Box 6 way (8+18) including required material
supplu and Installation MCB Box 8 way (8+24) including required material
supplu and Installation MCB Box 12 way (8+36) including required material
supplu and Installation Same board swithch and socket - 6 Amp. including required material
supplu and Installation Same board swithch and socket - 16 Amp. including required material
Modular Box/plate 2 module with required size and shape with switch and socket required
Modular Box/plate 4 module with required size and shape with switch and socket required
Modular Box/plate 6 module with required size and shape with switch and socket required
Modular Box/plate 8 module with required size and shape with switch and socket required
Modular Box/plate 10 module with required size and shape with switch and socket required
Modular Box/plate 12 module with required size and shape with switch and socket required
Modular Box/plate 18 module with required size and shape with switch and socket required
Modular Box/plate 24 module with required size and shape with switch and socket required
D.G. Set servicing 125 KVA
D.G. Set servicing 15 KVA
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
conditions.pdf
Tender Documents • 1.73 MB
document.pdf
Tender Documents • 2.14 MB
itemlist.pdf
Tender Documents • 2.36 MB
BOQ_547742.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid