Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.5 CrAccepted-AOC RAJAMMAL BUSINESS CENTER PLOT NO 192 3RD CROSS BRINDAVAN STREET SRINIVASA NAGAR MADURA PUZHUTHIVAKKAM MADIPAKKAM CHENNAI 600 091 | CHENNAI | CHENNAI | TAMIL NADU | 600091 | ₹38.5 Cr | L1 | Accepted-AOC Award of Contract to the L1 Bidder |
| 2 | L2₹39.0 CrRejected-Finance | ₹39.0 Cr | L2 | Rejected-Finance As per Tender |
| 3 | L3₹39.0 CrRejected-Finance | ₹39.0 Cr | L3 | Rejected-Finance As per Tender |
| 4 | L4₹40.1 CrRejected-Finance NO 1 8 SENTHILAGAM AINDHUPANAI KADACHANALLUR ERODE 638 008 | NAMAKKAL | TAMIL NADU | 638008 | ₹40.1 Cr | L4 | Rejected-Finance As per Tender |
| 5 | L5₹40.4 CrRejected-Finance 5 217 D1 TEACHERS COLONY MOHANUR ROAD NAMAKKAL 637001 | NAMAKKAL | TAMIL NADU | 637001 | ₹40.4 Cr | L5 | Rejected-Finance As per Tender |
| Sl No | Description | Qty | Unit | SSS HI TECH CONSTRUCTIONS PRIVATE LIMITED L2 | PSK ENGINEERING CONSTRUCTION AND CO L3 | POWERCONZ L1 | ABIRAMI ENGINEERING CONSTRUCTION AND CO L5 | PRIYA ENGINEERING PROJECTS PRIVATE LIMITED L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00SITE CLEARANCE | ||||||||
| 1.01 | Clearing Light jungle including uprooting of trunk vegetation,grass,brush wood,trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. | 17,560 | Sqm | 6 ₹1.2 L | 6.3 ₹1.3 L | 15 ₹3.1 L | 6 ₹1.2 L | 6 ₹1.2 L |
| 2.00DISMANTLING | ||||||||
| 2.01Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of walls | ||||||||
| 2.02 | Brick / Stone Masonry in cement mortar walls under 3m high | 37 | Cum | 240 ₹10,478.40 | 845 ₹36,892.70 | 2,500 ₹1.1 L | 1,000 ₹43,660 | 1,200 ₹52,392 |
| 2.03 | Brick / Stone Masonry in cement mortar walls, add for every additional 3m or part there of over the initial height of 3m | 25 | Cum | 240 ₹7,080 | 1,230 ₹36,285 | 3,000 ₹88,500 | 1,000 ₹29,500 | 1,440 ₹42,480 |
| 2.04 | Corrugated Iron Sheet Roofing over Pan Tiles without roof timbers | 146 | Sqm | 36 ₹6,202.08 | 120 ₹20,673.60 | 150 ₹25,842 | 35 ₹6,029.80 | 120 ₹20,673.60 |
| 2.05 | Dismantling RCC by manual / by using deploying
machineries | 47 | Cum | 4,800 ₹2.7 L | 2,300 ₹1.3 L | 4,000 ₹2.2 L | 3,500 ₹1.9 L | 4,200 ₹2.3 L |
| 3.00EXCAVATION | ||||||||
| 3.01Earth work excavation for foundation (for narrow excavation)in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2.00mts. and clearing and levelling the site, etc., complete complying with standard specification and as directed by the departmental officers. Note: The cost of earth work excavation shall be calculated based on the classifications of soils furnished in the trial pit details appended with the estimates | ||||||||
Tender Value
Refer Docs
EMD Value
₹19 L
Closing Date
4 Mar 2026, 3:00 pmClosed
The Managing Director
No.4, Rajiv Gandhi Salai, Taramani, Chennai 600113
E Tender for Construction of IT Office Building, Ground floor plus 4 Floors plus Terrace, including Civil Construction, HVAC, Electrical HTLT, Elevator, IBMS, Fire Protection, Plumbing, Structural Facade, Landscaping, STP, WTP at Karur.
2026_NEO_660848_1
TIDEL NEO/2025-26/6A
Open Tender
Construction Works
365 days
Karur
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹19 L
TIDEL Neo Limited
11 Mar 2026
19 Feb 2026
5 Mar 2026
19 Feb 2026
4 Mar 2026
28 Feb 2026
19 Feb 2026 - 23 Feb 2026
23 Feb 2026
SITE CLEARANCE
Clearing Light jungle including uprooting of trunk vegetation,grass,brush wood,trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
DISMANTLING
Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of walls
Brick / Stone Masonry in cement mortar walls under 3m high
Brick / Stone Masonry in cement mortar walls, add for every additional 3m or part there of over the initial height of 3m
Corrugated Iron Sheet Roofing over Pan Tiles without roof timbers
Dismantling RCC by manual / by using deploying machineries
EXCAVATION
Earth work excavation for foundation (for narrow excavation)in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2.00mts. and clearing and levelling the site, etc., complete complying with standard specification and as directed by the departmental officers. Note: The cost of earth work excavation shall be calculated based on the classifications of soils furnished in the trial pit details appended with the estimates
All Kind of Soil - (Upto 2.00m depth from NGL)
All Kind of Soil - (From 2.00m to 3.00m depth)
All Kind of Soil - (From 3.00m to 4.00m depth)
All Kind of Soil - (From 4.00m to 5.00m depth)
All Kind of Soil - (From 5.00m to 6.00m depth)
All Kind of Soil - (From 6.00m to 7.00m depth)
FILLING
Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15cm thick well rammed with surface vibrator, watered and consolidated etc., complete complying with standard specification and as directed by the departmental officers.
Supplying and filling in foundation, basement, etc with conveyed earth From Quarry about 13 KM in layers of not more than 150mm thick layers well watered, rammed with surface vibrator and consolidated including conveyance charges etc. complete complying with standard specification and as directed by the departmental officers.
Supplying and filling in foundation, basement, etc with filling crushed stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Supplying and filling in foundation, basement, etc with Filling Granular Sub Base in layers well watered, Without consolidation etc. complete complying with standard specification and as directed by the officers
Cement Concrete 1:4:8 (One Cement, Four crushed stone sand and eight hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers -Mixing by mechanical means
Foundation level, under Plinth protection, under drawf walls and ramps including ancilary bldgs.
FORM WORK
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid) Height 3.29m
Footing
Plinth Beam
Column upto Plinth Level
RCC Wall upto Plinth Level
Lintel at all Levels
Staircase at all Levels
Column above Plinth Level
RCC wall above Plinth level
Roof Beam/Column drop at all Levels
Roof Slab at all Levels
Providing additional strutting to centering of RCC slabs of plain surface for every additional 1.0 metre height or part thereof but not less than 30 cm, over the initial 3.00 metre height from floor level using casurina props of 10cm to 13cm dia including cross bracing etc., complete complying with standard specification and as directed by the department officers.
Extra for aditional 1 M above 3.90 M
REINFORCED CEMENT CONCRETE
M25 Grade Concrete
Providing and laying in position, Standardised Concrete Mix M-25 Grade using In-situ Concrete batching plant/ Ready Mix Concrete (RMC) adopting weigh batch method in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kglm3 and maximum water cement ratio of 0.50, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m’) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including Conveyance of concrete from batching plant to Work site, Electricity charges and other works & labour cost involved for concrete production, laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials)
Footing Concrete
M35 Grade Concrete
Providing and laying in position, Standardised Concrete Mix M-35 Grade using In-situ Concrete batching plant/ Ready Mix Concrete (RMC) adopting weigh batch method in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 425 kg/m3 and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m’) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including Conveyance of concrete from batching plant to Work site, Electricity charges and other works & labour cost involved for concrete production, laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).
RCC Lift Wall
Foundation upto the plinth level
Column
Foundation column upto the plinth level
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Terrace Floor
RCC Wall
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Terrace Floor
Floor Slab/Beam Concrete
M - 25 Grade of concrete
Providing and laying in position, Standardised Concrete Mix M-25 Grade using In-situ Concrete batching plant/ Ready Mix Concrete (RMC) adopting weigh batch method in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kglm3 and maximum water cement ratio of 0.50, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 Cu.m) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 Cu.m) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m’) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including Conveyance of concrete from batching plant to Work site, Electricity charges and other works & labour cost involved for concrete production, laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials)
Grade Slab
Plinth Beam
Floor Beam
First Floor & Boundary Wall Top Beam
Second Floor
Third Floor
Fourth Floor
Terrace & Mummty Floor
Floor Slab
First Floor
Second Floor
Third Floor
Fourth Floor
Terrace Floor
Mummty
Lintel & Staircase
First Floor
Second Floor
Third Floor
Fourth Floor
Terrace
STEEL REINFORCEMENT
Supplying, fabricating and placing in position Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete in all floors etc. complete complying with standard specification: Grade of Steel ( Fy )- Fe - 550 Confirm to IS : 1786: 1985.
Applying one coat of anticorrosive treatment on steel reinforcement rods (20 ltrs. Of anitcorrosive chemical for one mertic tonne of steel reinforcement rods) at site including a cost of required quantity of anticorrosive chemicals, (best approved quality) cement, consumables such as brushes, gloves and labour for anticorrosive coating etc. complete and as directed by the PMC/Employer. (The Quantity and brand of anticorrosive chemaical should be got approved by the PMC/Employer
MASONARY WORK
Masonry work FlyAsh Bricks of size 230 x 110 x 70 mm in cement mortar 1:6 (one of cement six of sand) for sub structure & super structure in all floors including fixing frames of door and windows, proper setting, curing etc., complete complying with standard specification as directed by the departmental officers.The rates including curing, providing and removal of scaffolding, cost of materials, labour, equipments and machinery, all leads and lifts, loading and unloading, transportation and all other incidential charges etc, all as complete and directed by Engineer in charge at all levels.
For Foundation and Basement.
For Superstructure in Ground Floor
For Superstructure in First Floor
For Superstructure in Second Floor
For Superstructure in Third Floor
For Superstructure in Fourth Floor
For Superstructure in Terrace Floor
Brick partition walls of 11.50cm thickness using best quality Fly Ash Bricks of size 23 x 11 x 7 cm in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers.The rates including curing, providing and removal of scaffolding, cost of materials, labour, equipments and machinery, all leads and lifts, loading and unloading, transportation and all other incidential charges etc, all as complete and directed by Engineer in charge at all levels.
For Superstructure in Ground Floor
For Superstructure in First Floor
For Superstructure in Second Floor
For Superstructure in Third Floor
For Superstructure in Fourth Floor
Damp proof course with Cement Mortar 1:4 (One Cement and Four crushed stone sand) 12mm thick mixed with best approved quality water proofing compound conforming to Indian Standard specification as specified by the departmental officers at 2% by weight of cement used, finishing and curing etc. complete complying with standard specification.
For Main Building
For Ancilary Building
JOINERIES (DOOR & WINDOWS)
Supply and erection of Double Leaves Fire Rated Door with Frame having the dimensions of 1200mmx2400mm & 750mmx1500mm with following specification:(Including Stickering works) a. Door Frame 1.6mm: Galvanized 120 GSM branded make JSW b. Door Leaf 1mm: Galvanized 120 GSM branded make JSW c. Shutter Thickness: 46mm d. Honeycomb: In-fill e. Glue Macroplast UR-7221 f. Door Hinges: 4" x 3" x 3mm, Double Ball: Make Assa Abloy Yale Ball bearing Butt Hinges Grade SS 304 - Finish SS g. Door Closer with Standard Arm Finish: Silver h. Lock Set: Dead Lock with both side key i. Door Orientation: To be confirmed by client j. Mounting of door: Brick wall mounted k. Powder Coating: Powder coated in standard RAL paint colour of PO Red (60 to 90) Microns l. Single Point Panic Bar (2 Horizontal): Make Assa Abloy Yale or Equivalent m. Dead Lock with both side key: Make Assa Abloy Yale or Equivalent n. Vision Panel 200 x 300mm 2 Hrs. Fire Glass Schott Pyran with Frame o. Rated Glass Schott Pyran with Frame p. Anchor Bolt with Endcaps The above assembly mounted on concrete or brick wall including the cost of cutting, chipping, concrete packing, plastering, scaffolding all other conveyence as per standard methods and as directed by the Departmental Officers/consultants.
Shaft Doors
Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer in charge
Double Leaf/ Single Leaf Door
Providing and fixing approved make and manufacture SS 304 grade Glass to Glass Lock Round type with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved make & manufacture SS 304 grade D type 600mm pull handle & stopper ISI marked with 32mm dia fixed with SS screws etc. complete in all respects as per manufacturers' specification & as directed by Engineer-in-charge.
Providing and fixing Automatic Sliding door operator, compliant with future European standards and produced according to the guidelines for power-operated windows, doors and gates, BGR 232, the UVV and the VDE regulations. TÜV design tested for Durability of 1,000,000 Cycles, Manufactured according ISO 9001, tested according to the low voltage guidelines, CE Compliant, fulfils DIN 18650 standards for Padestrian Safety, for framed glass door application with DORMA ST-Flex Profiles Systems, modular design including internal cover and with 12.52 mm Laminated glass for 1 Nos sliding door panels and 1 Nos fixed panels, both sliding & fixed panels with ST-Flex framed profile system with Interlocking Seals.Operator & Frame Finish should be Silver Anodised, with operator dimensions (H x D) : 100 x 180 mm and of length as required to suit the opening sizes as given below ES200 Operators are of very sturdy design with Self balancing Panel suspension system and with Anti-Jump fitting.The track profile should be separate from the main profile for enabling reduction in vibration insulation. Microprocessor-controlled control unit, Self-learning, with adjustable parameters for opening and closing speed, hold-open time and opening and closing force, reversing when obstruction is encountered, Class of protection IP 20 with SMPS for Power regulation. Activators- Nemo Motion + Nemo Dual ( Safety & Motion ) Pack, EM Lock - Fail Safe with CableProgram Switch with Key. Max Panel Weight Carrying Capacity of 1 X 200 Kgs. The system shall have constant power supply 230V+ 5%, 50Hz, AC . The requirement in total is as mentioned below:
Providing wood work (75mm X125mm) in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length. ( hold fast lugs or dash fastener shall be paid for separately).
Second Class Teak Wood
French Spirit Polishing: Two or more coats on new works including a coat of wood filler
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Supplying and fixing solid core flush shutter of following type with thickness and necessary T.W. internal lipping alround conforming to IS 2202-1(1999) including cost of wind appliances and furniture fittings such as 3 Nos of SS 304 Grade Parliament Hinges of Size (125mm x 150mm) , 2 Nos 300x12mm aluminium tower bolt 1 No. 200x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops, 2 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete complying with standard specification and as directed by the departmental officers - Single leaf. Door Shutter Type : Flush shutter Thickness:35mm
UPVC Ventilator : Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
UPVC Window Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Departmental Officer before use on work . SOR M-0674
Supplying, fabricating and fixing in position of Aluminium anodised natural colour matt finish of single leaf fully panelled sliding door with 12mm thick bothside prelaminated partile board at the Shutter bottom rail:[email protected] kg/m,Top & Verticle 50x44.45x2.50mm @ 1.292 kg/m,Lock rail 50x44.45x2.50mm @ 1.292 g/m, Running channel section:[email protected] kg/m, and necessary accessories such as Alu.clips 17.15x17.27x1.50mm @ 0.176 kg, Alu handle 100x30mm @ 0.988 kg/mfull length of handles on both sides, lock, roller, including cost of materials, labour charges and power consumption charges required for fabrication including chipping, dismantling and waking hole to the required extent in RCC column, beam masonry with power drill wherever necessary and redoing the damaged portion to the original condition afterfixing etc. complete. All the Alu. sections are to be anodised.with matt finish under electically contolled condition in accordance with IS 1868/1962 for an average anodic film thickness of 15 microns etc.,
Rolling Shutter - Gear/Electrical Operated Type (with / without Grill) Supplying and fixing rolling shutters of approved make, made of required size M.S. laths of size 80 x 1.20 mm interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation with rolling grills to the suitable size and shape etc complete including the cost of providing and fixing necessary 27.5 cm long good quality wire springs grade No.2 and M.S. top cover of 1.20 mm thick for rolling shutters. The rate shall be inclusive of one coat of red oxide primer and two coats of synthetic enamel paint of approved quality and colour. Complete in all respects complying with relevant standard specification, as directed by the departmental officers.
SS HANDRAIL
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia. Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete
Supply and installation of frameless glass railing system for a height of 1200mm from finished floor. The glass panel shall be of 12mm thick clear toughened glass connected to slab/beam by means of 304 grade stainless steel U-Channel at bottom with non staining weather sealant of approved make. On top, glass shall be held together by stainless steel round top U- channel of 25.4mm dia., all complete to perform as per approved detail drawings. The complete system to be designed to accommodate thermal expansion. The joint between glass panels & gaps at the perimeter & U – channel of the assembly to be filled with non-staining weather sealant, so as to make the entire system fully waterproof and dust proof. Setting block to be inserted inside U-channel at bottom for proper alignment of glass. The rate shall include all design, engineering & shop drawings including approval from structural design, labour, T&P, other incidental charges, SS Channel, laminated glass etc. All complete.
Providing and fixing of 3 Nos of stainless steel grab bars for special need including all fixtures and complete finish.
Providing and fixing welded M.S. grills for the window openings and any openings as per drawing with necessary screws, bolts and fixed with necessary M.S. lugs embedded in masonry with C.C. 1:2:4 and finishing the surface neatly. Design of grills and the size of members to be used shall be got approval before put into use & as directed by the departmental officers.
Manufacture, Supply, fabrication and Installation of Motorized Sliding Compound wall Gate as per detail drgs Number of leaves: as per design Mounting surface: as per design Bottom Rail : RCC Columns : RCC / M.S. Gate Design Pattern :Standard Mild Steel square hollow tubular section, torsion free fully welded unit Gate frame:M.S. pipe top/bottom horizontal & vertical profile Infill's : The infill's are to be fully welded between the upper & lower gate frame Cladding : (Optional if any applicable as per gate design) Bottom rail : C channel & 20mm round polished bar Bottom rollers: Italian make Galvanised Wheels 120mm dia.with ball bearings and axle with lubrication point (Appx. weight will be 80kg per Sqm )
Gate 01-Main entry-Two panels Telescopic sliding(equal divisions) - Automatic
Gate 02-Main exit-Two panels Telescopic sliding(equal divisions)
Manufacture, Supply, fabrication and Installation of Swing Type Openable Compound Wall Main gates and wicket gates of specified size and width constructed in MS frames as per design and detailed drawings including all accessories and hardwares and all fabricated and fixed as shown in the drawing, including buffing, painting 3 coats with approved shade epoxy paint over a coat of Zinc chromate primer / Anti corrosive painting etc. complete and all as directed. Rate shall include for fixing in position, alignment, grouting the MS support using cement concrete 1:2:4 and finishing the surface neat and smooth etc. as per drawing and specification complete as directed. Gate should get manufactured in factory & after inspection get dispatched to site except final coat of painting which will be done at site after installation (Appx. weight will be 80kg per Sqm )
Gate 04-OSR--Single panel Non-Telescopic sliding
Gate 08-Service - pedestrian entry-Single panel swing
Gate 05-Sub station-Single panel Non-Telescopic sliding
UGT/STP
PLASTERING
Plastering Internal with Cement Mortar 1:5 (One cement and M.sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the Engineer-incharge.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Terrace Floor
Plastering External with Cement Mortar 1:5 (One cement and Five Plastering sand), 20mm thick (12+8mm) in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
Ground Floor to Terrace Floor
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three M.Sand) 6mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the Engineer-in charge.
Plastering with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 12mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including mortar plasticizer at 200ml per 50Kg of cement used, finsihing, curing, etc., complete in all floors complying with standard specification and as directed by the departmental officers.
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
PAINTING
Supplying and painting the walls with two coats of wall putty as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications (The wall putty shall be got approved by the Executive Engineer before use of work).
White washing two coats with base primer ,brushes, scaffolding charges, etc., complete complying with standard specification and as directed by the department officers
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
Painting two coats of newly plastered wall surface with Weather Proof Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
Providing and applying Texture Finish Paint with Weather proofing compound (for External painting) and approved shade including preparation of surface for painting, applying primer and two or more coats of paint as per manufacturer’s specifications, scaffolding curing etc. complete as directed at all levels.
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Painting new wood/iron work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
FLOORING & CLADDING
Providing granolithic floor finish of the following thickness with plain cement concrete 1:2:4 (One Cement, Two crushed stone sand and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling, groove cutting wherever necessary and as directed by the departmental officers)
40mm thk
Paving the floor with best approved quality fine polished Kota stone slabs of size 600 x 600 of 18 / 20mm with machine cut edges and matching marble slab not less than 100mm width other than Adanga Marbles as border laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stone sand) fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments and polishing with floor polisher to a high degree of finish etc., The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
Using Fine polished Kota Stone Slab above 600 x 600 of 18 to 20mm size
Kota stone slabs 18 to 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Using Fine polished Kota Stone Slab above 600 x 600 of 18 to 20mm size
Supplying and fixing superfine polished Ruby red or equivalent colour Granite slab 18 to 20 mm thick for Lift facia with bullnose edges are set in adhesive for base and pointed with the same colour cement etc complete. The rate inclusive of labour charges for laying & pointing curing etc. complete
Supplying and fixing pre polished Ruby red or equivalent colour Granite slab 20 mm thick for Pantry and wash basin counter with bullnose edges are set in CM 1:3, 10mm thick for base and pointed with the same colour cement etc complete. The rate inclusive of labour charges for laying & pointing curing etc. complete
Paving the floor with best approved quality fine polished Granite Stone Slabs of size 1200 x 600 of 18 to 20mm thick of Synthetic Grey, Paradise and similar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stone sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
Fine Polished Granite Slab 1200 x 600 of 18 to 20mm thick of Synthetic Grey, Paradise and similar varieties
Granite wet cladding on walls/columns/cills/facias/ jambs/soffits /Bands/ skirting ;Providing and fixing Granite Stone machine cut and machine high prepolished best quality approved colour granite slab of thickness not less than 17/18mm for wall lining (veneer work)/ dado of approximate size 1200 x 600 / 900 x 600 mm, backing filled with a grout of average 18 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand) set in laticrete adhesive L290 or equivalent, including pointing with matching colour of Laticrete or Araldite Joint filler or approved equivalent to match the granite shade including rubbing, curing and polishing including chamfering and edge polishing at exposed surfaces etc. all complete as specified and as directed by the Engineer-in-Charge all complete as per Architectural drawings, and as directed by the Engineer-in-Charge. The cost to include all shuttering, scaffolding, props. Also it has to be ensured that the bedding mortar thickness is adjusted to achieve the desired level to flush the surfaces with adjoining finishes.
Fine Polished Granite Slab 1200 x 600 of 18 to 20mm thick of Synthetic Grey, Paradise and similar varieties
Paving the floor with best approved quality Flamed finish polished Granite Stone Slabs of size 1200 x 600 of 18 to 20mm thick of approved colour with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and finishing joint with Laticrete or Araldite joint filler or approved equivalent joint filler of approved shade etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
Paving the floor with best quality vitrified Tiles of following size and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laid over cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
600x600mm & 10mm thk. (Double charged)
Providing and laying Double Charged Vitrified Tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete.
Size of Tile 600x600 mm & 10mm thk (Double charged)
Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three crushed stone sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Dadooing walls with following best approved quality, white / colour glazed tiles conforming to IS 15622 of following sizes in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) Size of Tile 300x450x8mm
Vitrified Tile Cladding/ Dado Providing and laying Glossy/ satin matte finish Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to International Building Codes, of approved brand & manufacturer, in all colours and shade, on walls/ partitions etc in cladding/ dado laid with cement based high polymer modified quick set tile adhesive (water based) in average 6 mm thickness or set in 1: 4 Cement Mortar, including grouting of joints using epoxy grout stainfree Laticrete/ Balendura or of approved equivalent make and brand of 0.70 kg of organic filler of desired shade (0.10kg of hardener and 0.20 kg of resin per kg), including cutting/ mitring/ curing/ filling/ grouting and finishing complete as per direction of Engineer - in - charge Size of Tile 600x600 mm
Flooring with following ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three crushed stone Sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Dadooing walls with following best approved quality, white / colour glazed tiles of following sizes set in Cement Mortar 1:2 (One Cement and Two crushed stone sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.
Dadooing with white glazed tiles of size 150mm x 150mm x 6mm
Terrace screed: Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 10mm-12 mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.
Paving the Top of roof with Solar refelective ceramic tiles of approved quality and colour laid in Cement mortar bed in 1:3 (One cement and three crushed stone sand) 12mm thick and pointed with water resistant tile epoxy grout for joint, curing etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by the Executive Engineer before use on works) - IN OPEN TERRACE AREA.
Wall Panelling:-Providing Wall Panelling using one side teak wood sheet with melamine polishing with following specification. The frame using aluminium tubular section of size 50mm x 25mm x 2mm thick fixing horizontally and vertically in position with wall at interval of 0.60m in both diretions, fixing water proof plywood of 12mm thick over the aluminium frame work with necessary screws. One side teak wood sheet of 3.5mm thick will be fixed over the plywood using fevical and finishing with melamine polishing and the rate inclusive of conveyance to site and labour charges and as directed by the Departmental Officers. The design pattern, water proof plywood, OST sheet and other materials to be used shall be got approved by the Executive Engineer concerned before use on work etc., complete.
Providing groove on Grantine stone for Steps and Wall cladding
Providing and filling the tile joint with epoxy grout with following specification: Surface preparation including cleaning the joint to be free from dust and loose particles. Providing masking tape on either side of the tile joint edges and providing sealing the tile gap with epoxy tile joint grout and finishing neatly and as directed by the departmental officers. The rate inclusive of cost of materials and labour, etc., complete.
Providing PVC Trims (Beading) for Toilet dadooing tiles edges
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels Area of slab up tp 0.50 Sqm
WATERPROOFING
Below Grade Slab
Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded 1.5 mm thick HDPE waterproofing pressure sensitive adhesive membrane over PCC before laying raft concrete having higher puncture resistance of 1000N as per ASTM E 154, confirming to BS 8102 & IS 16471:2017, requirements of UG waterproofing structures. Laying adjacent sheets by keeping overlap of 75mm, end overlaps to be treated using double sided tape. The membrane shall have Tensile strength >25 Mpa as per ASTM D 412, Elongation > 500% as per ASTM D 412, Hydrostatic head resistance >70m head of water as per ASTM D 5385, Low Temperature Flexibility: -25 deg C, Peel Adhesion to Concrete >880 N/m as per ASTM D 903 Modified, UV Exposure > 45 Days. The finished cost including surface preparation completely as per specification.
Sunken Portion (Toilets & ODU's Platform)
Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination by rubbing with wire brush. Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed. Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete.
Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geotextile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids > 85%,Tensile strength >2 Mpa as per ASTM D 412, Elongation at break >400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness >55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo-textile over the angle fillet when the first coat in still wet, treatment of cracks and laying 120GSM Geo-textile as seperation /protective layer over the fully cured PU coating completely as per specification.
OHT/ UGT (inside) waterproofing with Antimicrobial Coating
Waterproofing: Providing and Applying CFTRI approved two component flexible polymer modified acrylic cementitious waterproofing coating with a mix ratio of (5 Liquid :7 Powder) to the RCC surface of the UGT/ OHT tank applied @ 2.2kg/m2 in 2 coats to achieve 1.2mm DFT, having Elongation at break >120% as per ASTM D 412, Tensile strength >1N/ mm2 as per ASTM D 412, Adhesion strength: 0.80N/mm2 as per ASTM D 4541, crack bridging upto 2mm as per ASTM C 836. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification. Followed by applying 15 mm thick dimensionally stable fibrous reinforced cementitious structural grade dual shrinkage Polymer Mortar on as protective plastering @ 29kg/m2. The material having Compressive strength of 38 MPa at 28 days as per EN 12190, Adhesive Bond Test, >1.5 Mpa as per EN 1542, followed by Water curing by sprinkling water for 3 times a day for 5- 7 days. Followed by applying two component, water-based food grade epoxy resin coatingon inside surface of Potable water tank having antialgae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 – 300 of US – FDA, having mixing Ratio (Base: Hardener: Water) – 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification.
STP (inside) waterproofing with Anticorrosive & Protective Coating
Providing and Applying two component flexible polymer modified acrylic cementitious waterproofing coating with a mix ratio of (5 Liquid :7 Powder) to the RCC surface of the STP tank applied @ 2.2kg/m2 in 2 coats to achieve 1.2mm DFT, having Elongation at break >120% as per ASTM D 412, Tensile strength >1N/ mm2 as per ASTM D 412, Adhesion strength: 0.80N/mm2 as per ASTM D 4541, crack bridging upto 2mm as per ASTM C 836. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification. Followed by applying 15 mm thick dimensionally stable fibrous reinforced cementitious structural grade dual shrinkage Polymer Mortar on as protective plastering @ 29kg/m2. The material having Compressive strength of 38 MPa at 28 days as per EN 12190, Adhesive Bond Test, >1.5 Mpa as per EN 1542, followed by Water curing by sprinkling water for 3 times a day for 5- 7 days. followed by applying two component coal tar epoxy-based coating on inside surface of Sewage & Effluent treatment tank @ 0.30 kg/m2 in 2 coats to achieve a DFT of 200 microns when fully cured. Ensure that this coating is applied over the protective plaster. The material shall have Scratch resistance, for 7kg load as per ASTM : D 7027 - 05, Chemical resistance, immersion in dilute acid alkali & salt solutions – 7 days confirms to ASTM : C 868, Salt Spray resistance confirms to ASTM : B 117.
FALSE CEILING
GYPBOARD FALSE CEILING
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x 0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks)
12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks)
CALCIUM SILICATE METAL WITH GRID CEILING
Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm,cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to formgrid module of size 600 x 600 mm, suspended from ceiling usinggalvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphey wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The workshall be carried out as per specifications, drawing and as per directionsof the Engineer-in- Charge.
With 15 mm thick Tegular edged light weight calcium sliciate false ceiling tiles
GRID CEILING
Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC 0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.
With semi perforated 12 mm thick micro tegular edged GRG false ceiling tiles.
Toilet Cubical- Providing and fixing Toilet Cubicle (of following standard dimension which includes 600 mm door size width) made of heat, bacteria, water, chemical, scratch, impact and anti bacterial resistant 12 mm thick solid compact laminate panels Finish of the compact laminate should be raw silk which include doors, pilasters and intermediate panels finished with approved texture/shade as per the detail drawing and as per IS 2046 (Indian Standard) and as per fire retardant BS-476/97 standard.This also includes providing and fixing in position necessary hardware made out of Stainless Steel (Grade 304) as per manufacturer's specifications and EIC instructions like (1) Door Knob, (2) Gravity Hinges, (3) Thumb turn lockset indicators, (4) Coat hooks, (5) U- Channels, (6) SS-Shoe Box Plate, (7) MS-Base Plate, (8) Rubber noise deafening tape, (9) Screws and wall Plugs. All screws will be of 304 Grade in stainless steel with satin finish. All pilasters are supported by series stainless steel shoe box with MS- Base Plate. The Base of stainless steel shoe box will be anchored to the floor with a clearance height upto 110 mm. Fixing of intermediate panels to the wall shall be stainless steel 'L'- Bracket or stainless U- Channel section are fixed into wall with screw inserts. All screws will be of 304 Grade in Stainless steel with satin finish. All pilasters are supported by stainless steel Bottom Cladding. The base of the stainless steel bottom cladding will be anchored to the floor with a clearance height upto 110 mm. All intermidiate panels shall be 12 mm thick, pilasters and door shall be 18 mm thick with edges chamfered complete as per drawing and directions of Engineer- In- Charge.
Toilet Cubicle with standard dimension of 1840 mm Height x 1000 mm width x 1550 mm Depth, which include 600 mm door size width). Toilet Cubicle I- Shape (Front Partion) with standard dimension of 1840 mm Height x 1000 mm width which includes 600 mm door size width).
MISCELLANEOUS
Providing Anti-termite treatment to soil adjecent and under building foundation, plinth periphery of the building by application of chemicals of IS 63613 part I to IV in stages to suit the progress of work consist as per the detailed specification as below. Including breaking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport and storing etc., complete and as directed by the departmental officers.
Sunken filling in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
Ground Floor
First Floor
Second Floor
Third Floor
Fourth Floor
Providing and fixing in position Heavy duty precast SFRC. manhole cover and frame.Square shape 600mm internal dimensions
Providing and fixing PVC coated MS rungs as per drawing and instruction of Engineer in-charge complete.
Water Stops for Joints : Supply and apply of WPM SW a swellable waterbar based on polymer technology and designed for use in construction joints.
Supplying and filling of Boulder by lorry for filling including conveyance loading and unloading charges and all other incidential charges filling laying watering and consolidation etc., complete as directed by the Dept., Officers with standard specification.
POLYURETHANE FOAM THERMAL INSULATION PANELS (PUF): Providing and Fixing of polyurethane foam as Internal Partition Wall Thermal insulation panels or Sandwich insulated panels wihboth internal and external 0.50mm total coated thickness repainted galvanized iron sheet with micro ribbed profile and the insulation material will be chlorofluoro carbon and hydro chlorofluoro carbon free , high performance rigid polyurethane foam (PUF) conforming to IS 12436 having density not less than 40±2Kg/M3, Thermal conductivity (K-Value) 0.024 W/m.K measured at 10 degree C mean temperature along with necessary flashings such as L flashing, C flashing etc& accessories such as screws ,fastners ,sealants etc for fixing the panel etc., complete complying with standard specification.
100mm thick PUF Internal Partition wall panel
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality, 1.5mm thick
Ground floor reception area
Extra for pre finished nosing to treads of steps of Granite stone
Electrical insulating mat of 6mm thick shall with standing voltage up to 65 Kv ac and 240V dc and every meter of mat tested and stamped to IS 15652-06 specifications with ISI Marking (1000mmx2000mmx6mm)
SS STRUCTURE & GLASS CANOPY WITH TIE ROD: Providing and fixing 13.52 mm laminated Toughned Glass (6mm clear toughned + 1.52mm PVB + 6mm Clear toughned) in canopy of structural Strainless steel frame work system in horizontal/inclined plane. The cost includes the cost of providing and fixing of glass with spider fitting and tie rod of Dorma/D-line make or quivalent and all necessary fittings for fixing of glass and joints will be sealed with wheather silicone of dow coming 789 grade to make joints leak proof and also includes all incidental includes all incidental works complete as per direction of engineer incharge.
The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints shall be measured.
Laminated glass to have / be: a) Comply with ASTM C1172. b) PVB interlayer complying with BS 6206 Class A. c) Edge steps less than 0.25mm in toughened or heat-treated glass. Annealed glasslaminate shall have no step. d) Bear identification marks indicating its nature and processor. e) Panes to have edges finished from the autoclave. Protect the interlayer material fromthe effects of moisture absorption in service including clouding, shrinking back,degassing and de-lamination. f) Ensure that the interlayer is compatible with glazing sealants. Undertake a compatibilitytest plus accelerated weathering to ensure that leeching does not occur. g) The glass shall not delaminate.
Providing and Supplying Stainless Steel Structure Fabricating, Assembling, hoisting, erecting and placing in position SS Built-up section/Tubular Structure ( SS built-up section :-Rolled section & plates confirming to Grade SS-316,Tubular Structure:- made from Steel hollow sections, ISI marked conforming to Grade SS-316, in the profile shape as per drawings. The structure has to be provided as per conceptual drawings and direction of Engineer-In-Charge.
The complete Stainless Steel structure to be Polishing and buffing are Mate Finishing Processes For Smoothing. The work is to be executed as per technical specification and direction of Engineer-In-Charge. Mode of Measurement is Surface Area of Glass
Supply ans Fixing of 3mm Glass Etching Sticker Grade No.1 Good quality Material in sticker cutting material For Entire building as required and directed by Engineer -in-Chief
Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture’s specification and direction of engineer in charge all complete.
75mm overall thickness partition with 12.5 mm thick double skin tapered edged plain Gypsum plaster board conforming to IS: 2095: (part I): 2011 (Board with BIS certification marks)
Making Core Cutting in slabs / beams / retaining walls and any other R.C members to any dia & depth by using 'approved' make diamond drilling machine with tolerance for any type of inserts, anchor fasteners etc. Rate shall include for sealing the gaps between RC surface and inserts with fire retardent grouting material as per manufactures specification ,all charge, preparation of surface, cutting of reinforcement, cleaning the surface, staging, scaffolding with necessary tools and equipments water and power, removal of debris from the site, staging scaffolding etc complete, as directed.
110 to 160 mm dia pipe to the following depth:
150 mm Depth
200 mm Depth
250 mm Depth
160 to 250 mm dia pipe to the following depth:
150 mm Depth
200 mm Depth
250 mm Depth
Designing, Providing and fixing in position Hot rolled structural steel Members / Sections consists of MS joists, channels, angles, purlins, pipes, hollow tubes, runners, insert plates, flats, gate for compound wall etc. at all levels. Rate to including all materials, labour charges, scaffolding, stagging, transportation, lead & Lifts, wastage, cost of bolts, nuts, washers, welding, electrodes and connections required for the work etc., as complete with all respects complying with relevant standard specification, as directed by the departmental officers.
Supplying, fabricating and placing in position M.S.chequered plate of required thickness of 5 mm for machine floors and shafts closing at all floors at all levels with necessary supports such as M.S. angles/M.S. flats including stiffeners to be placed on angle iron frame work. (Frame work, angles, stiffeners will be measured under relevant structural steel item). Rate shall include making necessary cutouts for inserts, All MS members shall be painted with 2 Coats (each coat of 25 microns DFT) of red oxide zinc phosphate primer and 2 Coats (each coat of 35 microns DFT) of synthetic enamel paint of approved colour and make etc,. Rate including all materials, labour charges, wastages, necessary lead and lifts, transportation charges, loading, unloading, scaffolding, staging, straightening, cutting, fabricating, welding, bending to shape bolting, installation charges, fuel, consumables as complete with all respects complying with relevant standard specification and as directed by the departmental officers.
Supplying and Fixing MS Ladder width 45cm using 50x50x6mm MS Angle. Rate to include primer, all material, labour charges etc., as complete with all respects complying with relevant standard specification, as directed by the departmental officers.
Supplying and fixing in position CI manhole covers with CI frames (Heavy duty) of size 60cm x 60cm of best approved quality as per standard specification etc., complete compying with standard specifications
ELEVATION
SEMI UNITIZED STRUCTURAL GLAZING SYSTEM
Designing the Semi Unitised Structural Glazing System with open groove joint as per design intent, preparation of shop drawings for approval, supply, fabricate, erect as per approved shop drawings at all floor levels and all floor heights including conducting field test as per the test criteria set out in the particular specification (Metholodgy should be got approved by the Dept. Officials.) Design the framing system (i.e. male & Female frame) to support vision panels, spandrel panels either with glass or aluminium composite panel, openable, window panels on a continuous framing supported between floors. Also design the split framing unutilized glazing system in case of strip or punched windows with vision panel proposed with either insulated / Monolithic glass, groove width in the system both in horizontal and vertical shall not be more than 20mm. Glazing of panel shall be done only at factory at the controlled atmosphere
Semi unitized system
Glass : Providing, assembling and Supplying of Double Glazed Performance glass, heat Strengthened clear Glass (IGUs) of size and shape as required and specified of approved, comprising of an outer heat strengthened clear glass of following thick of approved colour and shade with reflective soft coating on surface #2 and an inner heat strengthened clear glass of following thick , spacer tube 12mm wide , dessicants, including primary seal and secondary seal ( structural silicon sealant ) etc. all complete for the required performance , as directed by the engineer -in - charge. The heat strengthened clear glass having properties as visible Light transmittance (VLT) of 25 to 35 %, Solar heat gain coefficient less than or equal to 0.27 and U value of 3.0 to 3.3 W/m2 or lower degree K etc. The IGUs shall be assembled in the factory/ workshop of the glass processor. For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.(Including the Supply & Installation of perimeter firestop/ smoke seal tested as per NBC 2016/ IS 18190/ ASTM E 2307 standards to provide 2 hours fire & temperature ratings along with movement testings. The system should be designed & tested as per the above standards & the contractor should submit the relevant test certificates)
6mm+12mm+6mm
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings, the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in- Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.
ALUMINIUM COMPOSITE PANEL CLADDING
Providing and fixing of Aluminium Composite Panel (ACP) 4 sided having 50 x 25 x 1.50mm frame work vertical and horizontals out of specially designed extruded sections withstand wind pressure of 180 Kg/sq.m and fabricated fixed at all level elevation and heights. The extruded section cutting and fixing required space extruded section shall be of 6063 and alloy of BSH 9 confirming T is – 63400 rate shall included to fix the main frame with necessary clamps, fasteners, bolt nuts etc. The main frame of extruded section shall be of 22843 & 22739 (H9) grade conforming to BS 4174 (or) IS 8147. Rate shall included 4mm thick ACP sheet (0.25 + 3.5 + 0.25) alstrong or equivalent fixing with spacer tape and the ACP sheet bounded with special type structural sealant of dow corning 789 or equivalent in dust free conditions the gaps between ACP sheet to be filed with whether sealant and backer rod or 12mm foam sheet to ensure water and air tightness in all complete complying with standard specification as directed by the departmental officer
The surface will be finished with fluorocarbon -, coating in topsides and service coating on reverse side coating confirms to the mechanical properties of panel as per detailed drawing shall include all fixing accessories, screws, washers, bolts, nuts, cleats, other required fasteners, sealant brackets, etc., complete.
GLASS PARTITION
Supply and installation of dormakaba ALTERRA Access and Cabin System for minimal frame, room dividing solutions.Single glazed mullion free demountable glass partition using Toughened/ Laminated glass in proprietary natural anodised/Black aluminium sections ALT 50 of size 50mm x 30mm with Concealed sealing (No visible Gaskets/Seals) with acoustic rating of Minimum 32 db with third party test certificate. The profile will have Carpert Groove at the Bottom on both sides for accomodating max. 8mm carpets. THe Glass to be fixed with help of Proprietary Stability GRIPPER Clamp to have a stable system. It should consists of intermediate slim junction profiles for Glass to Glass vertical joints, 90 Degree L Junction and T Junction profiles suitably to be used as per room configuration designs.No VISIBLE Clip Lines to provide clutter free view at both side of section. The Glass to be Offset mounted towards outer edge leading to minimum aluminium frame on one side. Optional Profile Bottom Seal pair for additional accoustic if required. Glass thickness - 10/12/13.52mm( LSG). All Profiles are min 1.5mm thickness excluding 20 microns of Anodizing, Standards applicable • Structural stability test accordance to BS 5234: Part2:1992 & EN 1991-1-1:2002 • Acoustic test for sound insulation in accordance to DIN EN ISO 10140-2 ASTME-E 90 • ALT profile sections are manufactured and tested in accordance to EN573-3, EN755-2, DIN EN 12020 T2 , non- dimensions manufacturing tolerance deviation DIN ISO 2768-1 class C = coarse • Toughened glass complies accordance to BS 6262 (glass supplier specification from market) • Environmental product declaration (EPD) rating accordance to ISO 14025 & EN 15804 • HPDs - Ref HPD Unique Identifier; 22451 & 22452 - Classification : 09 84 00 Acoustic Room Components
MILD STEEL :Supply, Fabrication, erection, alignment of structural steel work as per approved shop drawing MS members are consist Vertical supports , Base plates with foundationBolts (Foundation works are civil contractor scope) included sections comprising of angle, plates, stiffeners, etc., Necessary permanent bolts & Nuts with washers, handling, straightening, cutting, drilling holes, welding, shop assembly, transport to erection at site, storing, leading to erection site. All MS members are 1 coat of Red oxide Primer and 1 Coat of Painting as per approved make - Asian paint prior to erection.
Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.
Providing & fixing concept wallpapers with wording & arts etc. as per direction of engineer-in charge.
PVC / Fibre Glass Framed 5.5mm thick Mirror, Shelf Type with Hard Board Backing
Road and Land Development
Providing and laying 83mm thick faciory made cement concrete interlocking paver block of M -40 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge
Providing and laying 500x500x40mm thick Turf paver (Turfpave XD)on 150mm thick sub grade of compacted bed of 20mm thick nominal size stone aggregate and base course and filling with 150mm thick jamuna sand, including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer-in-charge.
Construction of Subgrade (Construction of subgrade with approved material having CBR 8% or more with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2)
Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size 35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours).Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing , specification and direction of PMC/Employer
Mandatory/ Regulatory sign boards of 900 mm diametre with support length of 3750 mm
Cautionary /warning sign boards of equilateral triangular shape having each side of 900 mm with support length of 3650 mm
Manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type - III of ASTM-D-4956-01 as approved by PMC/Employer, letters, borders etc. as per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the PMC/Employer(Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment). Overhead informatory road signage
Providing and fixing Glow studs of size 100x20 mm made of heavy duty body shall be moulded ASA (Acrylic styrene Acryloretrite ) or HIP (High impact polystyrene) or ABS having electronically welded micro- prismatic lens with abrasion resistant coating as approved by Engineer in charge. The glow stud shall support a load of 13635 kg tested in accordance with ASTM D4280. The slope of retro- reflective surface shall be 35 (+/-5) degress to base .The reflective panels on both sides with at least 12 cm of reflective area up each side. The luminance intensity should be as per the specification and shall be tested as described in ASTM I: 809 as recommended in BS: 873 part 4 : 1973. The studs shall be fixed to the Road surface using the adhesive conforming to IS, as per procedure recommended by the manufacturer complete and as per direction of PMC/Employer
Supplying of Solar Raised Pavement Markers made of polycarbonate molded body with circular shape, solar powered,LED self illumination in active mode, 360 degree illumination and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face in passive mode. The marker shall support a load of 20000 kg tested in accordance to ASTM D 4280. The marker should be resistant to dust and water ingress according to IP 65 standards and should withstand temperatures in the range of 0 C to 70 C. Color of lighting could be provided in red or yellow (amber) as per requirement and typical frequency of blinking is 1 Hz. There should be current losses of less than 20 microamperes at 2.4 V in sleepcharging mode to enhance the life of the marker and a full charge should provide for a minimum autonomy of 50 hours. The height, width and length of the marker shall not be less than 10 mm x 100 mm x 100 mm. Also, the surface diameter of the marker shall not be less than 100 mm respectively. The weight of the marker shall not exceed 0.5 Kilograms. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive and complete as directed by the engineer.
Supply of imported outdoor Polycarbonate Convex Mirror with 130 Degree + actual viewing angle, equipped with adjusting swivel and mounting bracket for infinite adjustment. Diameter – 100 cm outdoor
Providing and fixing Rubber Speed Breaker in yellow & black shade with load capacity of 30 ton, moisture resistant of size 500mm 350mm x 50mm & having end cap from both ends as per approved make by design architect. ( Rate to include the required hardware accessories etc )
Supply & installation of 40 inch Concave mirror with scratch proof & dimensional accuracy with required accessories, Hardware, etc of approved make from design architect & as per manufcaturers specificaiton
Manufacturing, supply & fixing of precast kerb stone of size 450mmx300mmx150mm thick made of M 25 grade of concrete rectangular in shape with one corner chamfered by 100 mm x 100 mm as per approved design i/c cost of all material, labour and curing etc., complete. as per IRC 5758 - 1984.
Providing and laying of hot applied Thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform and free from streaks and holes etc., complete as per MoRT&H specification No.803
LANDSCAPE & SOIL Works
Providing,stacking and planting of Plumeria rubra of height 120-150 cm. With 3-4 branches and thick stem in big size HDPE bags as per direction of the PMC / Employer.
Providing and fixing Neelgiri/Mexican grass turf with earthy 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light, watering direction of officer incharge.
Providing, stacking and planting Acalypha red well developed with fresh & healthy 30 to 45 cm ht. in 20 cm size Earthen Pot/ Plastic Pot as per direction of the PMC / Employer.
Planting of Adenium (Adenium obessum) Specimen plant variety of height 105-120 cm in polythene bag of size 16x16 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the PMC / Employer.
Ground covers: Towards cost and supply of Ground covers, inclusive of pitting and planting (1 Sqm)
Hedges: Towards cost and supply of Hedges, inclusive of pitting and planting
Accent Trees: Towards cost and supply of Accent trees, inclusive of pitting and planting
Providing,stacking and planting of Plumeria rubra of height 120-150 cm. With 3-4 branches and thick stem in big size HDPE bags as per direction of the PMC / Employer.
"Supplying and Planting of Terminalia Metalica (Terminalia mantalay variegated) ornamental foliage Specimen plant variety of height 105-120 cm in polythene bag of size 16x16 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the PMC / Employer."
palms: Towards cost and supply of Accent palms, inclusive of pitting and planting
Supplying and Planting of Dypsis lutescens (Areca palm) palm variety of height 180-210 cm in polythene bag of size 16x16 inch including supporting stack of 5 cm dia casurina pole of 10 feet height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the PMC / Employer.
Irrigation works: Earth work, PVC pipe, 360degree Adjustable POP –Up Springler, Motor and Accessories Value
Providing corrugated galvalume sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.5mm thick
Providing expansion joint of 12.5mm wide in between RCC twin columns from top of pedastal to full height including filling the inner space with suitable non-absorbent, flexible and well compressible filler materials of approved quality and brand; finishing the sides of RCC columns with polysulphide sealents for a depth of 7.5mm on either side covering the inner space filled with filler materials as above etc., complete complying with standard specifications and as directed.
Supplying and fixing in position of 2''x2'' size chain link fencing 10 gauge and fixing with M.S. Angle post using 16 gauge G.I. Wire including running the 2 ply and 4 pin G.I. barbed wire 12 gauge at bottom, middle and top of M.S. angle posts (As stiffner to the chain link fencing) etc, complete copmplying with standard specification.
SIGNAGES
Notes: 1. The colour, pattern, texture, size, font to be strictly as approved by Client / Architect / PMC. Vendor to show the samples for approval before procuring. 2. Working at all levels and heights and as directed by the departmental officer. 3. Necessary samples, print outs and fixing details to be submitted for Architect's approval 4. All the texts shall be bilingual, unless specified otherwise
The Supply and fixing of the below listed items with necessary accessories for complete installation to the satisfaction of departmental officer at all levels and heights.
Internal Signs
Logo with back dropwith LED backlight Gold plated SS sheet fabricated sign in 16swg, text etched in color specified, with protective coating in 50mm box finish, sign to be fixed with concealed SS fixtures:
Tidel Logo: 15" x 48"
Neo Logo: 9" x 24"
Reception Table - 10'' x 36'' , Titanium Gold Letter - TIDEL NEO
Reception back drop way finding 18''x30''
Acrylic based sign with foam base in Photo luminescent topped with reflective vinyl in color specified, sign to be fixed with adhesives on location identified
Size : 18"X4" - For Service rooms with "Entry Restricted" text
Size : 12"X3" - For Store room, Janitor etc.,
Size: 7" x 7.75" - Floor numbers: Ground to Terrace number to be fixed on landing of all fire exit stairs
Brushed Stainless Steel plate 18swg sign with text PUSH PULL etched in black, sign to be pasted on door with strong adhesives. Size: 6" x 2"
Brass Plate sign with given text etched in color specified, sign to be fixed with adhesives / 3M Ds tapes on door / on wall with 4mm acrylic black spacer of same size mounted with SS Screws, the Gold finish sign pasted on top with adhesives with no fixtures visible
Sign size: 4" x 1.5" - Lift Numbers: LIFT -1, LIFT -2…. etc.,
Sign size: 7" x 7" - Floor Numbers opposite Lift area: From Ground to 3rd floor
Sign size: 6" x 6" - Ladies toilet, Gents toilet and Physically challenged with Pictograph
Reception mural art wall below Neon Light signage 18''x60''
Tidel office- wall mounted without lighting 24''x48'', 3d letters
Conference room - wall mounted above door frame Titanium single sided Individual room - 8''x36''
Office signages / STP / WTP/ Sub station/ Pump room etc 24''x6'' square, titanium letter acrylic titanium top
Safety Signs
Acrylic based sign with foam base in Photo luminescent topped with reflective vinyl in color specified, sign to be fixed with adhesives on location identified
Size: 12" x 4": FIRE EXIT direction: Double sided suspended sign with SS Chain
Size: 12" x 4": FIRE EXIT direction: Single sided suspended sign with SS Chain
Size: 12" x 4": FIRE EXIT: Door sign : To be fixed near all fire exit doors
Size: 24" x 3" : PUSH BAR TO OPEN. Vinyl sticker to be fixed above panic bar
Size: 6" x 6": Standard pictograph for Manual call point and Fire Hose reel to be fixed in the locations as directed
Size: 8" x 8": Standard pictograph for Fire Extinguisher to be fixed in the locations as directed.
Size: 24" x 36": STP, Tank Yard
Egress route: Fire evacuation plan to a Size: 18" x 12" : Clear acrylic sandwich sign showing the latest plan with fire evacuation route in photo luminescent base, sign to be fixed with SS studs
External Signs
Supply & fixing of “TIDEL Neo” (in Tamil) & TIDEL OF SIZE (34' x 4' ) WITH gib ASE Tricmp Cap type Front light letters using Front Acrylic 3” raising illuminated using 12V ADS chip LED or equivalent make with a rainproof proper power supply) with Timer & all supporting structurel support and acessories TIDEL NEO – 34' X 4 feet ( Building Top -Elevation)
Supply & fixing of “TIDEL Neo” (in English) with a size (12’x3’) with 12mm Foam with Tricmp Cap Tyope Front Light letters using front Acrylic 3” Raising illuminated using 12V ADS chip LED or equivalent make with a rainproof proper power supply with Timer & all supporting structurel support and acessories TIDEL NEO 12 x 3 feet - Drop-off Zone (in Wall)
Supply & fixing of TIDEL NEO (in English) Logo of Size: 18’x1.5’with back supported runner type structure using 3”x1” Paint coated MS Frame with GI base Tricmp Cap Type Front Light letters using Front Acrylic 3” raising illuminated using 12V ADS chip LED or equivalent make with a proper power supply. with Timer & all supporting structurel support and acessories TIDEL NEO 18x1.5 feet (Entrance Gate)
Supply & fixing of TIDEL NEO (in Tamil) Logo of Size: 18’x1.5 ’with back supported runner type structure using 3”x1” Paint coated MS Frame with GI Base Tricmp Cap Type Front Light Letters using front Acrylic 3: Raising Illuminated using 12V ADS chip LED or equivalent make with a Rainproof proper power supply.with Timer & all supporting structurel support and acessories TIDEL NEO 18x1.5 feet (Entrance Gate)
Entry and Exit Signs : Sign size: 12" x 6" Aluminium 2mm base plate with reflective vinyl of Kiwalite make mounted in color specified, sign to fixed with SS Studs on wall.
HT INSTALLATION AND ALLIED WORKS
11kV HT RMG PANEL (Outdoor)
Supply, installation, testing and commissioning of 11kV, Outdoor type HT RMG Panel, totally enclosed, type tested as per IEC 62271-200 floor standing, sheet steel clad cubicle pattern, consisting of the followings: Incomer-1 : 1 No. 11KV, 630Amps HT Load Break Switch (LBS) with Earth switch, RYB LED Indication lamps, control wiring, etc., Incomer-2 : 1 No. 11KV, 630Amps HT Load Break Switch (LBS) with Earth switch, RYB LED Indication lamps, control wiring, etc., Outgoing : 1 No. 11KV, 630Amps, 25kA, Electrically Drawout type HT VCB complete with RYB LED Indication lamps, CT-PT Arrangements, control wiring, etc., and separate space provision compartment for mounintg the EB Trivector Meter (TVM), Trolley for VCB, HT Surge Arrestors, 800Amps, Copper Busbar arrangments with PVC Sleeves, supports, etc., as per TANGEDCO Specifications and requirements.
11kV DP STRUCTURE"
Supply, erection, Testing and commissioning of the '11KV Two pole (DP) structure using 2 Nos. of 200 x 100mm ISMB Poles, of 9.145 meter long with 450 x 450 x 6mm base plate welded to the pole bottom, '1 Set of 100 x 50 x 6mm ISMC and angles, clamps to support the A.B. switch, H.G. fuse, line disc insulators, pin insulators, Lightning arresters,' M.S. clamps to fix the channels made out of 50 x 8mm M.S. flats and required angles as struts for cantilever projection to mount the A.B. switch, stay sets cable supports etc., Supply and fixing of 11KV, 400A double break tandem operated A.B. switch with operating pipe, operating handle with ON-OFF position indications and locking facility, guided, flexible earth for down rod pipe and other accessories, 1Set of 11KV HG fuse, 3 Nos. of station type 11kV Lightning arrestors, 11KV HT Pin insulators with long pin / A stool - 12 nos, 11kV Disc insulators with metal parts - 6 Nos., Stay set complete with guy insulators - 2 Set, "0" SWG Copper jumpering arrangments, etc., and complete painting works. 'Note : Including All civil work like excavation, concreting, and back filling, etc.
GI FENCING & GATE
Fencing : Fencing with 75 x 75mm 10SWG chain link mesh to a height of 1.8Mtrs. above ground level and a retaining wall with brick all around to a height of 330mm above ground with vertical members of 50 x 50 x 6mm M.S. angles at 1.5mtr. Intercal and tie angle at top with 25 x 25 x 6 M.S. angle.
Gates : 1.8mtr. Height and 1mtr. Width single leaf gate made out of 50mm Dia Round Pipe as Frame the frame to be Supported by 75mm Dia round MS Pipe and covered with 50 x 50 mm weld mesh with pad locking arrangements.
Gates : 1.8mtr. Height and 2x1mtr. Width Double leaf gate made out of 50mm Dia Round Pipe as Frame the frame to be Supported by 75mm Dia round MS Pipe and covered with 50 x 50 mm weld mesh with pad locking arrangements.
Levellilng the HT Yard using spreading 40mm blue metal to a height of 75mm and river sand bed upto 75mm height.
11KV HT SIGLE VCB PANEL (OUTDOOR)
11KV HT 3VCB (1IC+2O/G) PANEL (OUTDOOR)
11kV/433V, 630kVA TRANSFORMER WITH OLTC
Design, Supply, Erection,Testing and Commissioning 11kV/433V, 630kVA TRANSFORMER with OLTC & RTCC Panel comprising of bi-directional roller, diagram, rating plate, winding temperature indicator, marshalling box, lifting lugs and weather proof HT cable box, LT Cable box disconnecting chamber minimum 8mm thick non magnetic gland plate complete as per specification and as per IS : 1180 / 2026 and as per the ECBC norms. a) Copper wound On Load Tap Changer Transformer b) IS : 1180 (Part I) : 2014 ,Amendment No.4, Level-II c) Capacity - 630 KVA, Dyn 11 d) Primary - 11000 Volts e) Secondary - 433 Volts f) On Load Tap Changer, +/-10% Iin steps 1.25% g) HV - 28 KV h) LV - 3 KV i) ONAN, Outdoor type
HT CABLE & END TERMINATIONS
Supply and Laying of 11KV 3 Core 240 Sq.mm, HT XLPE insulated (E) Aluminium cable. The cable shall be laid in the cable tray which is fixed inside the cable trench as required as per the site condition
Supply and fxing of the HT Cable Heat shrinkable outdoor type end termination kit for suitable for terminating 3core 240 Sq.mm, HT XLPE Aluminium [E] cable with all the accessories.
Supply and fxing of the HT Cable Heat shrinkable Indoor type end termination kit for suitable for terminating 3core 240 Sq.mm, HT XLPE Aluminium [E] cable with all the accessories.
CONTROL CABLES & TERMINATIONS
Supply and laying of the following 1.1KV grade PVC copper control cables laid on cable trays / cable trench / wall / clamped inside the enclosure complete with necessary clamps and hardwares as required.
2C x 2.5 Sqmm copper armoured cable (HT VCBs)
3C x 2.5 Sqmm copper armoured cable
4C x 2.5 Sqmm copper armoured cable
4C x 4.0 Sqmm copper armoured cable
24C x 2.5 Sqmm copper armoured cable
Supply and providing end termination for the following cables by using suitable single compresson gland and copper sockets as required. The cost of earthing glad with copper strips/wires shall also be included.
2C x 2.5 Sqmm copper armoured cable
3C x 2.5 Sqmm copper armoured cable
4C x 2.5 Sqmm copper armoured cable
4C x 4.0 Sqmm copper armoured cable
24C x 2.5 Sqmm copper armoured cable
EARTHING
Supply, installation and testing of UL Listed 17.2mm dia. 3000mm long, copper bonded rod earth electrode station complying to IS 3043 standards in all respects with excavation in all types of soil, murrum or rock, filling with earth enhancing compound material, durable 450mm x 450mm masonry chamber in rich plastered brick work and approved quality heavy duty CI or RCC cover, etc., The earth pit identification shall be marked with paint on the cover in an approved manner. (HT DP Structure / HT RMG - 4 Nos, Transformers & DG Sets - 8 Nos. HT VCB - 4Nos., LT Panels - 4 Nos, Rising Mains - 4 Nos, UPS - 6 Nos, Lifts-6Nos, ELV & Server-4 Nos, & Utility - 6 Nos., Miscellaneous - 8 Nos.)
Supply, installation and testing of Copper Plate earth electrode station using 600 x 600 x 3.15mm Copper plate with 50mm dia. 3mtr long GI pipe with watering funnel, 2Rx25x6mm Copper strip as vertical run, connecting top clamp, etc., complying to IS 3043 in all respects with excavation in all types of soil, murrum or rock, filling with earth enhancing compound material, durable 450mm X 450mm masonry chamber in rich plastered brick work and approved quality heavy duty CI or RCC cover, etc., The earth pit identification shall be marked with paint on the cover in an approved manner. (Transformer, DG & UPS neutral earthing)
25 x 3mm copper flats for Rising Mains, Sub-Panels, Lifts, Utility Services, UPS, Fire MCC & EV Charging Earthing
50 x 10mm copper flat for 630KVA Transformer & DG, RMU, HT PANEL neutral earthing
08 SWG bare Copper earth wire
10 SWG bare Copper earth wire
Supply and Laying 50 x 10mm GI Flat
Supply and Laying 25 x 6mm GI Flat
SAFETY EQUIPMENTS
Supply and Installation of Danger Boards 11000V / 415Volts (Stove enamelled) as per EB & CEIG standards.
Supply and fixing of Fire buckets with round bottom, each set comprising 4Nos.fire buckets of 9Kg capacity including, M.S pedestal stand with hooks suitable for holding of 4Nos of fire buckets, painted with Post Office Red oil paint and letter FIRE on each bucket and filling with sand complete as required. .
11kv highly insulated fibre glass FRP EARTH / DISCHARGE ROD KUSAM MECO MAKE Or eqvt-03x5feet-assembled height 15 feet-30mm dia die cast aluminium earthing instrument to grip, 7/20 cu wire -7m, Rubber hand grip 2 set, with canvas cover for carrying Die cast alu. grounding “C” Clamps
HT / LT Cable route marker (Cast Iron) with cement concrete 1 :2:4 of size 60cm X 60cm at the bottom and 50cm X 50cm at the top with a thickness of 10cm including inscription duly engraved as required
2m x 1m Rubber Mat suitable for 11 KV installation confirming to IS (5 Nos)
First Aid box with medicines
First Aid Treatment Chart with duly framed with local languages & English
11kV Hand Glouse (ISI approved) with Box
L.T. SWITCHGEAR (PANEL BOARDS)
The Switchboard shall be designed so as to receive cables suitable for bottom / top entry and bottom / top exit to suit site conditions. For complete technical details refer schematic drawing/layouts.. The panel shall be Double front/single front "Linear" or "L" or "U" shape to suit proposed electrical room. Panel shall be powder coated with approved shade.'Rate shall include necessary sheet steel enclosure made out of 14 SWG sheet steel duly powder coated with the same paint shade of panel board adopter box to cover the cables and conduits above the panel to the acceptance of Consultant.'Design, manufacturing, Supply at site, Unloading, Leading, Positioning, Erecting, Earthing, Testing and Commissioning of panels of free standing type, vermin proof, construction as per tender technical specification and the details mentioned separately,'Note: All MCCBs in all panels shall have rotary handle mechanism and spreader wherever necessary.,'All ACBs with shutter release assembly, door interlock,'As per specification all outgoing MCCBs in the Main panel / distribution boards and incoming MCCBs of all Sub distribution panel boards shall be of adjustable overload and short circuit protection settings.'The outgoing MCCBs in the Sub Panels needs adjustable thermal overload settings only and fixed short circuit setting.'i. 35KA - above 250A up to 630A ii. 25KA for above 63A & up to 250A. iii. 16KA - up to 63A.'The KA rating of the MCCBs shall follow as per the BOQ. The KA rating for the Incomer of the Vertical MCCB DBs shall be of 16 KA rating only.'Details of LT Panels : The details of components, ratings etc. of all panels are furnished in Power distribution schematic diagram,'Electrical Room Size : Vendor/Contractor to ensure that the panel/room layouts are designed with adequate clearances as per IE rules in the proposed Electrical rooms and can be accommodated in the designated space for electrical rooms.
MAIN LT PANEL
Design, fabrication, supply, installation, testing and commissioning of cubicle floor mounting type, Indoor-IP54, compartmentalized, cable alley chamber, dust and vermin proof Panel boards made out of 14SWG CRCA sheet comprising of the followings:
EB INCOMER - 1 & 2: 2 Nos. 1000Amps, 50kA, 4Pole. Electrical Draw out type Air Circuit Breaker with Shunt release, UV release and E/F Releases and microprocessor based LSING with current metering display system
EB METERING - 1 & 2: 2 Set of RYB Phase indication LED lamps 2 set of Breaker ON, Breaker OFF, Breaker Trip LED indication lamps 2 No. Digital type Multi Function Meter with RS485 port 2 Set of 1000/5A, CL-1 Resin Cast CT for metering 2 set of 1000/5A, CL-5P10 Resin Cast CTs for Protection relay 2 set of 1000/5A, Cl-1 CT for APFCR Panel sensing 2 Nos. CDG-11 Overcurrent & Earth fault relay 2 Set of LVM, SPP and PPR. 4 Set of Control MCBs 2 Set of Surge Protection Device (Type-1+2) with MPCB 2 Nos. T-N-C Control Switch
DG NCOMER - 1 & 2: 2 Nos. 800Amps, 50kA, 4Pole. Electrical Draw out type Air Circuit Breaker with Shunt release, UV release and E/F Releases and microprocessor based LSING with current metering display system
DG METERING - 1 & 2: 2 Set of RYB Phase indication LED lamps 2 set of Breaker ON, Breaker OFF, Breaker Trip LED indication lamps 2 Nos. Digital type Multi Function Meter with RS485 port 2 Set of 800/5A, CL-1 Resin Cast CT for metering 2 Set of LVM, SPP and PPR. 4 Set of Control MCBs 2 Set of Surge Protection Device (Type-1+2) with MPCB 2 Nos. T-N-C Control Switch
SOLAR INCOMER: 1 Nos. 125Amps, 25kA, 4Pole. TM Based MCCB - 1Nos
BUS COUPLER : 1 No. 1000Amps, 50kA, 4Pole. Electrical Draw out type Air Circuit Breaker with E/F Releases and microprocessor based LSING with current metering display system
BUS BAR: (Copper) 1000Amps, 50kA, for 1 Sec. TPN, Copper bus bars (Current Density not less than 1.2A/Sq.mm) with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable copper earth bus.
Cable Entry & Exit : Top / Bottom Gland Plate : 3mm thickness removable plate Space heater with thermostat for Cable chambers
Complete with PLC with HMI based Interlocking system for automatic load balancing and load sharing options during power failure / changeover time
OUTGOINGS: 4 Nos. 800Amps, 50kA, TP+N, MCCB with microprocessor based OL & SC and extended RHOM, spreaders, phase barriers, etc., 4 Nos. 400Amps, 35kA, TP+N, MCCB with microprocessor based OL & SC and extended RHOM, spreaders, phase barriers, etc., 2 No. 320Amps, 35kA, TP+N, MCCB with microprocessor based OL & SC and extended RHOM, spreaders, phase barriers, etc., 4 Nos. 250Amps, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC and extended RHOM, spreaders, phase barriers, etc.,
Note : All the Outgoing feeders shall be having "ON-OFF" LED Indication lamps with Digital type MFM with RS485 port (Make: Selec MFM 384-C-CE). Suitable size outgoing cable chamber and extension busbars with shrouded partition between each outgoing feeder should be provided for connecting the number of outgoing cables as per the schematic drawing. The board shall be fabricated for future extension and complete with 75x40mm ISMC base frame arrangements.
APFCR PANEL - 1 & 2
Design, fabrication, supply, installation, testing and commissioning of cubicle floor mounting type, Indoor-IP54, compartmentalized, cable alley chamber, dust and vermin proof APFCR Panel boards made out of 14SWG CRCA sheet comprising of the followings:
INCOMER: 1 No. 400Amps, 35kA, TP+N, MCCB with microprocessor based OL & SC and extended RHOM, spreaders, phase barriers, etc.,
METERING: 1 Set of RYB Phase indication LED lamps 1 set of Breaker ON, Breaker OFF, Breaker Trip LED indication lamps 1 No. Digital type Multi Function Meter with RS485 port 1 Set of 400/5A, CL-1 Resin Cast CT for metering 1 No. 12Stage Microprocessor based APFC Relay . 1 Set of Control MCBs
BUS BAR: (Copper) 400Amps, 35kA, for 1 Sec. TPN, Copper bus bars (Current Density not less than 1.2A/Sq.mm) with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable copper earth bus.
Cable Entry & Exit : Top & Bottom Gland Plate : 3mm thickness removable plate Space heater with thermostat for Cable chambers
1 No. 50kVAR, Heavy duty APP type capacitor bank with capacitor duty contactor, 7% Detuned copper reactor, ON-OFF Illuminated Push buttons, control MCB, internal control and power wiring arrangements, etc., and controlled by 1 No. 160Amps, 25kA, TP+N, MCCB with thermal magnetic based OL & SC releases and extended RHOM, spreader terminals, phase barriers, etc.,
2 Nos. 25kVAR, Heavy duty APP type capacitor bank with capacitor duty contactor, 7% Detuned copper reactor, ON-OFF Illuminated Push buttons, control MCB, internal control and power wiring arrangements, etc., and controlled by 2 Nos. 100Amps, 25kA, TP+N, MCCB with thermal magnetic based OL & SC releases and extended RHOM, spreader terminals, phase barriers, etc., with 1 No. Dummy chamber suitable for 25kVAR
3 Nos. 15kVAR, Heavy duty APP type capacitor bank with capacitor duty contactor, 7% Detuned copper reactor, ON-OFF Illuminated Push buttons, control MCB, internal control and power wiring arrangements, etc., and controlled by 3 Nos. 63Amps, 25kA, TP+N, MCCB with thermal magnetic based OL & SC releases and extended RHOM, spreader terminals, phase barriers, etc.,
2 Nos. 10kVAR, Heavy duty APP type capacitor bank with capacitor duty contactor, 7% Detuned copper reactor, ON-OFF Illuminated Push buttons, control MCB, internal control and power wiring arrangements, etc., and controlled by 2 Nos. 40Amps, 25kA, TP+N, MCCB with thermal magnetic based OL & SC releases and extended RHOM, spreader terminals, phase barriers, etc.,
3 Nos. 05kVAR, Heavy duty APP type capacitor bank with capacitor duty contactor, 7% Detuned copper reactor, ON-OFF Illuminated Push buttons, control MCB, internal control and power wiring arrangements, etc., and controlled by 3 Nos. 32Amps, 25kA, TP+N, MCCB with thermal magnetic based OL & SC releases and extended RHOM, spreader terminals, phase barriers, etc.,
EV CHARGING MAIN PANEL (Outdoor Type)
Design, fabrication, supply, installation, testing and commissioning of cubicle floor mounting type, Outdoor-IP66, compartmentalized, cable alley chamber, dust and vermin proof EV Charging Main Panel board made out of 14SWG CRCA sheet comprising of the followings:
INCOMER: 1 No. 315Amps, 35kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreader terminals, phase barriers, etc.,
METERING: 1 Set of RYB Phase indication LED lamps 1 set of Breaker ON, Breaker OFF, Breaker Trip LED indication lamps 1 No. Digital type Multi Function Meter with RS485 port 1 Set of 320/5A, CL-1 Resin Cast CT for metering 1 Set of Control MCBs
BUS BAR: (Copper) 320Amps, 35kA, for 1 Sec. TPN, Copper bus bars (Current Density not less than 1.2A/Sq.mm) with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable copper earth bus.
Cable Entry & Exit : Bottom Gland Plate : 3mm thickness removable plate Space heater with thermostat for Cable chambers
OUTGOINGS: 3 Nos. 125A, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL and SC releases and extended RHOM, spreaders , phase barriers, etc., 4 Nos. 63A, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL and SC releases and extended RHOM, spreaders , phase barriers, etc.,
All the outgoing feeder considered with ON-OFF LED Indication lamps and control wiring arrangements, etc.,
UTILITY PANEL:
Design, fabrication, supply, installation, testing and commissioning of cubicle floor mounting type, Indoor-IP54, compartmentalized, cable alley chamber, dust and vermin proof Utility Panel board made out of 14SWG CRCA sheet comprising of the followings:
INCOMER: 1 No. 250Amps, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreader terminals, phase barriers, etc.,
METERING: 1 Set of RYB Phase indication LED lamps 1 set of Breaker ON, Breaker OFF, Breaker Trip LED indication lamps 1 No. Digital type Multi Function Meter with RS485 port 1 Set of 250/5A, CL-1 Resin Cast CT for metering 1 Set of Control MCBs
BUS BAR: (Copper) 250Amps, 35kA, for 1 Sec. TPN, Copper bus bars (Current Density not less than 1.2A/Sq.mm) with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable copper earth bus.
Cable Entry & Exit : Top Gland Plate : 3mm thickness removable plate Space heater with thermostat for Cable chambers
OUTGOINGS: 2 Nos. 160A, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreaders , phase barriers, etc., 3 Nos. 125A, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreaders , phase barriers, etc., 2 Nos. 100A, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreaders , phase barriers, etc., 4 Nos. 63A, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreaders , phase barriers, etc.,
All the outgoing feeder considered with ON-OFF LED Indication lamps and control wiring arrangements, etc.,
STP PANEL:
Design, fabrication, supply, installation, testing and commissioning of cubicle floor mounting type, Indoor-IP54, compartmentalized, cable alley chamber, dust and vermin proof STP Panel board made out of 14SWG CRCA sheet comprising of the followings:
INCOMER: 1 No. 100Amps, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreader terminals, phase barriers, etc.,
METERING: 1 Set of RYB Phase indication LED lamps 1 set of Breaker ON, Breaker OFF, Breaker Trip LED indication lamps 1 No. Digital type Multi Function Meter with RS485 port 1 Set of 100/5A, CL-1 Resin Cast CT for metering 1 Set of Control MCBs
BUS BAR: (Copper) 100Amps, 25kA, for 1 Sec. TPN, Copper bus bars (Current Density not less than 1.2A/Sq.mm) with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable copper earth bus.
Cable Entry & Exit : Top Gland Plate : 3mm thickness removable plate Space heater with thermostat for Cable chambers
PHE PUMP PANEL:
Design, fabrication, supply, installation, testing and commissioning of cubicle floor mounting type, Indoor-IP54, compartmentalized, cable alley chamber, dust and vermin proof PHE Pump Panel board made out of 14SWG CRCA sheet comprising of the followings:
INCOMER: 1 No. 160Amps, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreader terminals, phase barriers, etc.,
METERING: 1 Set of RYB Phase indication LED lamps 1 set of Breaker ON, Breaker OFF, Breaker Trip LED indication lamps 1 No. Digital type Multi Function Meter with RS485 port 1 Set of 160/5A, CL-1 Resin Cast CT for metering 1 Set of Control MCBs
BUS BAR: (Copper) 160Amps, 25kA, for 1 Sec. TPN, Copper bus bars (Current Density not less than 1.2A/Sq.mm) with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable copper earth bus.
Cable Entry & Exit : Top Gland Plate : 3mm thickness removable plate Space heater with thermostat for Cable chambers
LIFT MAIN PANEL:'
Design, fabrication, supply, installation, testing and commissioning of cubicle floor mounting type, Indoor-IP54, compartmentalized, cable alley chamber, dust and vermin proof LIFT Main Panel board made out of 14SWG CRCA sheet comprising of the followings:
INCOMER: 1 No. 125Amps, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreader terminals, phase barriers, etc.,
METERING: 1 Set of RYB Phase indication LED lamps 1 set of Breaker ON, Breaker OFF, Breaker Trip LED indication lamps 1 No. Digital type Multi Function Meter with RS485 port 1 Set of 125/5A, CL-1 Resin Cast CT for metering 1 Set of Control MCBs
BUS BAR: (Copper) 125Amps, 25kA, for 1 Sec. TPN, Copper bus bars (Current Density not less than 1.2A/Sq.mm) with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable copper earth bus.
Cable Entry & Exit : Top Gland Plate : 3mm thickness removable plate Space heater with thermostat for Cable chambers
OUTGOINGS: 6 Nos. 63A, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL and SC releases and extended RHOM, spreaders , phase barriers, etc.,
All the outgoing feeder considered with ON-OFF LED Indication lamps and control wiring arrangements, etc.,
Ground floor Panel
Design, fabrication, supply, installation, testing and commissioning of cubicle floor mounting type, Indoor-IP54, compartmentalized, cable alley chamber, dust and vermin proof SSB Panel boards made out of 14SWG CRCA sheet comprising of the followings:
INCOMER - 1 & 2 2 Nos. 250Amps, 25kA, 4Pole, Motorised type MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreader terminals, phase barriers, etc.,
Electro-Mechanical Interlocking arrangements between Incomer -1 and Inocmer-2 for Auto Changover system
METERING: 2 Set of RYB Phase indication LED lamps 2 set of Breaker ON, Breaker OFF, Breaker Trip LED indication lamps 2 No. Digital type Multi Function Meter with RS485 port 2 Set of 250/5A, CL-1 Resin Cast CT for metering 1 Set of Control MCBs
BUS BAR: (Copper) 250Amps, 25kA, for 1 Sec. TPN, Copper bus bars (Current Density not less than 1.2A/Sq.mm) with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable copper earth bus.
Cable Entry & Exit : Top Gland Plate : 3mm thickness removable plate Space heater with thermostat for Cable chambers
OUTGOINGS: 2 Nos. 125A, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreaders , phase barriers, etc., 4 Nos. 100A, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreaders , phase barriers, etc., 2 Nos. 63A, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreaders , phase barriers, etc.,
CT: 120/5A, CL: 1, - 6Nos, CT: 100/5A, CL: 1, - 12Nos. CT: 30/5A, CL: 1, - 6Nos, Digital MFM with RS485 Port - 8Nos
Note : All the Outgoing feeders shall be having "ON-OFF" LED Indication lamps with Digital type MFM with RS485 port (Make: Selec MFM 384-C-CE). Suitable size outgoing cable chamber and extension busbars with shrouded partition between each outgoing feeder should be provided for connecting the number of outgoing cables as per the schematic drawing. The board shall be fabricated for future extension and complete with 75x40mm ISMC base frame arrangements.
Typical Floor Panel (1F-4F)
Design, fabrication, supply, installation, testing and commissioning of cubicle floor mounting type, Indoor-IP54, compartmentalized, cable alley chamber, dust and vermin proof SSB Panel boards made out of 14SWG CRCA sheet comprising of the followings:
INCOMER - 1 & 2 2 Nos. 250Amps, 25kA, 4Pole, Motorised type MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreader terminals, phase barriers, etc.,
Electro-Mechanical Interlocking arrangements between Incomer -1 and Inocmer-2 for Auto Changover system
METERING: 2 Set of RYB Phase indication LED lamps 2 set of Breaker ON, Breaker OFF, Breaker Trip LED indication lamps 2 No. Digital type Multi Function Meter with RS485 port 2 Set of 250/5A, CL-1 Resin Cast CT for metering 1 Set of Control MCBs
BUS BAR: (Copper) 250Amps, 25kA, for 1 Sec. TPN, Copper bus bars (Current Density not less than 1.2A/Sq.mm) with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable copper earth bus.
Cable Entry & Exit : Top Gland Plate : 3mm thickness removable plate Space heater with thermostat for Cable chambers
OUTGOINGS: 6 Nos. 100A, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreaders , phase barriers, etc., 2 Nos. 63A, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreaders , phase barriers, etc.,
CT: 100/5A, CL: 1, - 18Nos. CT: 60/5A, CL: 1, - 6Nos, Digital MFM with RS485 Port - 8Nos
Note : All the Outgoing feeders shall be having "ON-OFF" LED Indication lamps with Digital type MFM with RS485 port (Make: Selec MFM 384-C-CE). Suitable size outgoing cable chamber and extension busbars with shrouded partition between each outgoing feeder should be provided for connecting the number of outgoing cables as per the schematic drawing. The board shall be fabricated for future extension and complete with 75x40mm ISMC base frame arrangements.
TERRACE FLOOR PANEL
Design, fabrication, supply, installation, testing and commissioning of cubicle floor mounting type, Indoor-IP54, compartmentalized, cable alley chamber, dust and vermin proof SSB Panel boards made out of 14SWG CRCA sheet comprising of the followings:
INCOMER - 1 & 2 2 Nos. 250Amps, 25kA, 4Pole, Motorised type MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreader terminals, phase barriers, etc.,
Electro-Mechanical Interlocking arrangements between Incomer -1 and Inocmer-2 for Auto Changover system
METERING: 2 Set of RYB Phase indication LED lamps 2 set of Breaker ON, Breaker OFF, Breaker Trip LED indication lamps 2 No. Digital type Multi Function Meter with RS485 port 2 Set of 250/5A, CL-1 Resin Cast CT for metering 1 Set of Control MCBs
BUS BAR: (Copper) 250Amps, 25kA, for 1 Sec. TPN, Copper bus bars (Current Density not less than 1.2A/Sq.mm) with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable copper earth bus.
Cable Entry & Exit : Top Gland Plate : 3mm thickness removable plate Space heater with thermostat for Cable chambers
OUTGOINGS: 2 Nos. 125A, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreaders , phase barriers, etc., with Digital Multi Function Meter with RS485 port (Selec MFM 384-C-CE) and Current Transformers 02 Nos. 63A, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreaders , phase barriers, etc., 09 Nos. 32A, 25kA, TP+N, MCCB with adjustable thermal magnetic based OL & SC releases and extended RHOM, spreaders , phase barriers, etc.,
CT: 120/5A, CL: 1, - 6Nos. Digital MFM with RS485 Port - 2Nos
Note : All the Outgoing feeders shall be having "ON-OFF" LED Indication lamps with Digital type MFM with RS485 port (Make: Selec MFM 384-C-CE). Suitable size outgoing cable chamber and extension busbars with shrouded partition between each outgoing feeder should be provided for connecting the number of outgoing cables as per the schematic drawing. The board shall be fabricated for future extension and complete with 75x40mm ISMC base frame arrangements.
RISING MAINS -1 & 2
Supply and installation of Sandwich type 3P+100% Neutral 4Wire. 800Amps, 4Pole Copper Rising Mains with external 25 x 3mm Copper earth strips, all the fixing accessories.
Supply and installation of End Feed unit with 800Amps, 4Pole, 50kA EDO type ACB with OL & SC releases, operating rotary extended handle, adopter box, ON-OFF LED Lamps, flexible terminations (wherever required), etc., with all the fixing accessories. With third Party intergration system. including CT: 800/5A, Cl: 0.5 - 3Nos with MFM Meter with RS485 Port with necessary accessories and wiring etc,.
Supply and installation of Tap-off box with 250Amps, 4Pole, 25kA, MCCB with Rotary handle and all the fixing accessories
DISTRIBUTION BOARDS
Supply and erection of 3Phase, 6Way Vertical type VTPN MCCB Distribution board of IP43 double door type comprising of the followings: Incomer : 1 No. 63Amps, 25kA, 4Pole, MCCB Outgoings: 6 Nos. 32Amps, TP MCBs Complete with necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be readymade (powder coated type) fixed with concealed system in wall/ fixed in column. The rate shall include necessary connected civil works like chipping, rough plastering etc., (Tenant Offices Main DB)
Supply and erection of 3Phase, 6Way Vertical type VTPN MCCB Distribution board of IP43 double door type comprising of the followings: Incomer : 1 No. 100Amps, 25kA, 4Pole, MCCB Outgoings: 2 Nos. 63A TP MCB, 2 Nos. 32A TP MCB & 6 Nos. 32A SP MCBs Complete with necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be readymade (powder coated type) fixed with concealed system in wall/ fixed in column. The rate shall include necessary connected civil works like chipping, rough plastering etc., (Cafeteria & Conference DB)
Supply and erection of 3Phase, 6Way Vertical type VTPN MCB Distribution board of IP43 double door type comprising of the followings: Incomer : 1 No. 63Amps, 4Pole, MCB Outgoings: 2 Nos. 32Amps TP MCB & 12 Nos. 32Amps SP MCBs Complete with necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be readymade (powder coated type) fixed with concealed system in wall/ fixed in column. The rate shall include necessary connected civil works like chipping, rough plastering etc., (Tidel Office & IBMS Main DB)
Supply and erection of 3Phase, 4Way Vertical type VTPN MCB Distribution board of IP43 double door type comprising of the followings: Incomer : 1 No. 40Amps, 4Pole, MCB Outgoings: 12 Nos. 32Amps SP MCBs Complete with necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be readymade (powder coated type) fixed with concealed system in wall/ fixed in column. The rate shall include necessary connected civil works like chipping, rough plastering etc., (Tidel Office & IBMS UPS DB,)
Supply and erection of 3Phase, 6Way Vertical type VTPN MCB Distribution board of IP43 double door type comprising of the followings: Incomer : 1 No. 63Amps, 4Pole, MCB Outgoings: 1 Nos. 32Amps TP MCB & 15 Nos. 32Amps SP MCBs Complete with necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be readymade (powder coated type) fixed with concealed system in wall/ fixed in column. The rate shall include necessary connected civil works like chipping, rough plastering etc., (Corridor Main DBs)
Supply and erection of 3Phase, 4Way Horizantal type TPN MCB Distribution board of IP43 double door type comprising of the followings: Incomer : 1 No. 40Amps, 4Pole, MCB Outgoings: 6 Nos. 32Amps dP MCB MCBs Complete with necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be readymade (powder coated type) fixed with concealed system in wall/ fixed in column. The rate shall include necessary connected civil works like chipping, rough plastering etc., (Main EMG DB TP DB GF ELV ROOM)
Supply and erection of 3Phase, 6Way Vertical type VTPN MCB Distribution board of IP43 double door type comprising of the followings: Incomer : 1 No. 63Amps, 4Pole, MCB Outgoings: 4 Nos. 32Amps TP MCB & 6 Nos. 32Amps SP MCBs Complete with necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be readymade (powder coated type) fixed with concealed system in wall/ fixed in column. The rate shall include necessary connected civil works like chipping, rough plastering etc., (ATM DB & Aux. PDBs)
Supply and erection of 3Phase, 4Way Vertical type VTPN MCB Distribution board of IP43 double door type comprising of the followings: Incomer : 1 No. 40Amps, 4Pole, MCB Outgoings: 12 Nos. 32Amps SP MCBs Complete with necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be readymade (powder coated type) fixed with concealed system in wall/ fixed in column. The rate shall include necessary connected civil works like chipping, rough plastering etc., (Cafeteria PDB, Terrace LPDB)
Supply and erection of 3Phase, 6Way Vertical type VTPN MCB Distribution board of IP43 double door type comprising of the followings: Incomer : 1 No. 63Amps, 4Pole, MCB Outgoings: 3 Nos. 32Amps TP MCB & 9 Nos. 20A/25A/32Amps SP MCBs Complete with necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be readymade (powder coated type) fixed with concealed system in wall/ fixed in column. The rate shall include necessary connected civil works like chipping, rough plastering etc., (Substation Main TPDB)
Supply and erection of 3Phase, 4Way Vertical type VTPN MCB Distribution board of IP43 double door type comprising of the followings: Incomer : 1 No. 63Amps, 4Pole, MCB Outgoings: 4 Nos. 32Amps TP MCB Complete with necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be readymade (powder coated type) fixed with concealed system in wall/ fixed in column. The rate shall include necessary connected civil works like chipping, rough plastering etc., (External TPDB)
Supply and erection of External Lighting Controller box comprising of the followings: 1 No. 63Amps, 4Pole, MCB with 1 No. 63Amps, 4Pole Power contactor with Street light control timer, A/M Control switch, internal control wiring, etc., (External LDB Controller)
Supply and erection of 1Phase, 8Way SPN MCB Distribution board of IP43 double door type comprising of the followings: Incomer : 1 No. 32Amps, 2Pole, MCB Outgoings: 8 Nos. 16Amps SP MCB Complete with necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be readymade (powder coated type) fixed with concealed system in wall/ fixed in column. The rate shall include necessary connected civil works like chipping, rough plastering etc., (Security. Signage LDB, Cafeteria LDB Corridor LDBs, Food Court DBs & ELDBs)
Supply and erection of 1Phase, 6Way Horizontal TPN MCB Distribution board of IP43 double door type comprising of the followings: Incomer : 1 No. 63Amps, 4Pole, MCB Outgoings: 2 Nos. 40Amps 4P MCB & 3 Nos. 25A DP MCBs Complete with necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases. The board shall be readymade (powder coated type) fixed with concealed system in wall/ fixed in column. The rate shall include necessary connected civil works like chipping, rough plastering etc., (Lift DB-1 to 3)
Supply and erection of 1Phase, 3Pin, 16A/20Amps, Industrial type plug and socket with 25Amps, 30mA DP RCCB in a suitable size powder coated type enclosure with all the fixing accessories (Make: Legrand Tempra Model)
Supply and erection of 230V, 25Amps MCB Producted Socket with Pin top with necessary accessories.
Supply and erection of 6-32Amps, DP MCB in a suitable size powder coated type enclosure with all the fixing accessories for UPS Input and output controls
Supply and erection of 6-32Amps, 4P MCB in a suitable size powder coated type enclosure with all the fixing accessories for UPS Iput and output controls
Supply and erection of 63Amps, 4P MCB in a suitable size powder coated type enclosure with all the fixing accessories for UPS Iput and output controls. (For ATM)
CABLES AND TERMINATION: Supply and Laying of following size PVC/XLPE (FR-LS) insulated outer sheathed (1100 V grade) copper/aluminium armored & un armored conductor cable partly laid in cable tray and partly laid in wall/ ceiling with suitable individual clamps at every 1 mtr interval . Cable tray will be measured and paid separately. Cable Tags to be provided at every 50mtr interval and at either side of the bends.Only for Lighting cables cable tie will be permitted other cables clamps to be provided. Supply For all items in section-D, the rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same
3.5 Core 300 Sq.mm XLPE Aluminium armoured Cable
3.5 Core 240 Sq.mm XLPE Aluminium armoured Cable
3.5 Core 185 Sq.mm XLPE Aluminium armoured Cable
3.5 Core 150 Sq.mm XLPE Aluminium armoured Cable
3.5 Core 70 Sq.mm XLPE Aluminium armoured Cable
3.5 Core 50 Sq.mm XLPE Aluminium armoured Cable
3.5 Core 35 Sq.mm XLPE Aluminium armoured Cable
3.5 Core 25 Sq.mm XLPE Aluminium armoured Cable
4 Core 16 Sq.mm XLPE Aluminium armoured Cable
4 Core 10 Sq.mm XLPE Copper unarmoured Cable
4 Core 4 Sq.mm XLPE Copper armoured Cable
3 Core 2.5 Sq.mm XLPE Copper unarmoured Cable
Supply and fixing of LT Cable end termination kit (Glands & lugs) of the following size cables with suitable double compression glands with suitable crimping socket. The rate shall be inclusive of Gland Earthing Plate Prefabricated as per Gland Size with provision for connecting Cu.SWG and Cable Tags should be engraved type for all I/C,O.G& lighting Circuits (copper sockets for copper cables and Alu. Sockets for alum. Cable)
3.5 Core 300 Sq.mm XLPE Aluminium armoured Cable
3.5 Core 240 Sq.mm XLPE Aluminium armoured Cable
3.5 Core 185 Sq.mm XLPE Aluminium armoured Cable
3.5 Core 150 Sq.mm XLPE Aluminium armoured Cable
3.5 Core 70 Sq.mm XLPE Aluminium armoured Cable
3.5 Core 50 Sq.mm XLPE Aluminium armoured Cable
3.5 Core 35 Sq.mm XLPE Aluminium armoured Cable
3.5 Core 25 Sq.mm XLPE Aluminium armoured Cable
4 Core 16 Sq.mm XLPE Aluminium armoured Cable
4 Core 10 Sq.mm XLPE Copper unarmoured Cable
4 Core 4 Sq.mm XLPE Copper armoured Cable
3 Core 2.5 Sq.mm XLPE Copper unarmoured Cable
TRENCHING AND EXCAVATION
Supply and Laying of 4 x 10 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
WIRING - CIRCUIT CUM POINT WIRING The rates for all point wiring items shall also include supplying and fixing of the Conduits, conduit specials, bushes and other fittings,Approved GI saddles and grouting the same for exposed conduit work,2 mm thick Outlet boxes and junction box,All fixing accessories such as clips, brass screws etc,All work & materials necessary for wiring a point circuit of any length from the Final Distribution Board to connector via switch and shall include the circuit wiring also except where identified.
Primary Light / Fan Point Wiring: Supply, wiring, connecting and commissioning of 3Runs 1.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistranded FRLSH copper wires in 1.8mm thick MS conduits fixed on ceiling partly and 2mm thick PVC conduit concealed in the wall partly with necessary clamps, screws, etc., as required as per the site condition including supplying and fixing of modular 6A One way switch along with moulded front plate in GI anodised manufacturer's mounting box-Flat switches with indication fixed flush with the wall complete with all accessories including 3 plate ceiling rose. NOTE: Above false ceiling when it is open wiring it should be of MS conduit
Secondary Light Points: The secondary light points will have to be wired from the primary light point as mentioned above.
Lighting Circuit Mains: Supply and laying of 3 Runs 2.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistranded FRLSH copper wires in 1.8mm thick MS conduits fixed on ceiling partly and 2mm thick PVC conduit concealed in the wall partly with necessary clamps, screws, etc., as required as per the site condition., from LDB to Lighting Switch Boards and MCB to First Light Point.
TWO-WAY POINTS SITC of Concealed Point wiring (from Switch board) including Concealed Circuit Wiring (from DB to switch board) for two way like staircase points after cutting grooves on wall/ RCC, neatly filling the grooves with cement mortar, making good thereof, etc. using 3 x 1.5 Sq. mm. heavy duty PVC insulated copper conductor stranded cable (1 for earthing),2 Nos. Modular 2-way switch complete with non metallic inner & outer plates, suitable metal boxes, etc,IS marked (IS 9537 Part-3) suitably sized heavy duty rigid concealed MS conduits (20mm min), Saddles, junction boxes, bends, other accessories, ceiling roses, etc.
Ceiling Fan Points: Supply,installation,testing and commissioning of ceiling fan points same as Primary Light Point Wiring but for ceiling fan points including supplying and fixing concealed type fan hook box and supply and fixing of electronic type 300W fan step regulator with moulded front plate in GI anodised manufacturer's mounting box fixed flush with the wall complete with all accessories as required as per the site conditions.
Emergency Lighting Circuits: Supply and laying of 3 Runs 1.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistranded FRLS copper wires in 1.8mm thick MS conduits fixed on ceiling partly and 1.8 mm thick PVC conduit concealed in the wall partly with necessary clamps, screws, etc., as required as per the site condition., from ELDB to Emergency Light fittings.
Supply and fiixing of 10W-Integrated LED Bulk Head luminaire comprises of Pressure Die Cast housing
SOCKET OULETS
Supply, Installation, testing and commissioning of 1 no 6A Universal switched socket and with moulded front plate, GI anodised enclosure, and mounting box in the wall(concealed/open)and other associated accessories including chasing embedding rough plastering as required as per the site conditions for power points.
Supply, Installation, testing and commissioning of 2nos 6A Universal switched socket ( UPS) and 2nos 6A switches and with moulded front plate, GI anodised enclosure, and mounting box in the wall(concealed/open)and other associated accessories including chasing embedding rough plastering as required as per the site conditions for power points.
Supply, Installation, testing and commissioning of 1 no 6/16A universal switched socket and with moulded front plate GI anodised enclosure in the wall/floor(concealed/open and other associated accessories including chasing embedding rough plastering as required as per the site conditions for power points.
Supply and Laying of 2R x 4 sq.mm and 1R x 4.0 Sq.mm. PVC insulated FRLSH multistranded cu wires 25mm dia 2mm thick PVC conduit with all accessories (From DB to 16A Socket / 20A Metal clad plug & socket)
LED LIGHT FITTINGS
Supply and fixing of WT bulk head fitting with guard suitable with 7W / 9W LED bulb
Supply and fixing of 1200mm (48") sweep AC ceiling fan 5 star rated complete ( Higher end) with 2 module 100W fan step regulator (Higher end) with 1 metre down rod with fan clamp with side plates and cross arm of size 450mm (18")
Supply and fixing of 300mm (12") sweep (light duty) AC exhaust fan complete without provision of hole in the wall
Supply and erection of 4' LED batten with wattage 18W and System Efficacy & System lumens of ≥110 lm / W with 2000 lm respectively. The type of LED shall be SMD type mounted on MCPCB which is mechanically fixed (no glue pasting) with CCT of 6500K and CRI > 80. The housing material shall be aluminium with polyester powder coating. The life of batten shall be 35000 hours at L70. The IP rating of the luminaire shall be IP20. The ambient temperature shall be 0-45deg C. The lumianire optical element shall be UV protected polycarbonate. The lumianaire shall be operable from 140 - 270V AC with PF > 0.9 and THD < 10%. The driver shall be encapsulated type and placed within the luminaire. The driver shall be with in-built surge protection of 3kV. Drivers shall be flicker free and complies to IEEE P1789 standard. The effieciency of driver shall be > 90%. The luminaire shall be BIS approved and carry “R” number. Similar to Signify (Philips) Cat No. BN170C LED20S 6500 PSU L120
Supply and fixing of 18W LED 3000K Round Type Recessed Fitting with with all the fixing accessories (20Watts)
Supply and fixing of 24W LED 4000K 2ft x 2ft Square Type Recessed Fitting with all the fixing accessories
Supply and fixing of IP20 LED surface mounted circular metal downlighter suitable for general lighting. Luminaire should have polycarbonate cover with diffused optics. The luminaire should have CRI > 80, SDCM<5 and CCT of 6500K. The fixture should have a minimum system efficacy of 110 lumen/Watt (±10%) and a minimum system lumen output of 1500 lumens and system wattage of 13.5 Watts. The product shall have internal surge protection of 2.5kV. The luminaire shall be designed so as to ensure 50K burning hrs. @ L70 @ ambient temp 45 deg C. The electronic driver used shall have a power factor >0.9 , THD <10% ,similar to signify cat ref. SM296C LED15S-6500 PSU WH
Supply and fixing of 2' LED batten (Mirror light) with Co-extruded polycarbonate housing and mounded end caps. The system wattage shall be 12W with system lumens of 1200 lumens and system efficacy of 100 lm / W. LED make: that satisfies IEC62471 Photobiological/RoHS Standards with, Colour Temperature-6500K or Higher with LED binning as per ANSI Bin C78.377A, 120Deg LED Beam Angle, CRI > 80, Life of LED as per L70 > 20000burning hours, Ambient temp-0 to 35DegC, Driver efficiency>85%, THD<30%, Power factor>0.9. similar to signify cat ref BN021 LED12S 6500 PSU GR
Supply and laying of LED Strip type light fitting with driver and all the fixing accessories (5Watts per Mtr). Similar to signify cat ref LS170S LED12 840 IP20 L5000 G2
Supply and erection of 10W LED Up/down wall mounted fixture with 24 Deg Beam angle,Die cast housingand system efficacy100 lm/w, IP65, IK08,CCT 3000K, THD<5%, Surge 4KV. Similar to signify model no BWP102 LED10S 830 CYL 24D UP/DN GR
Supply and erection of 11Watts, 1000mm Height IP65 rated Bollard type light fitting with MS base, concreting and masonry work for fixing the post, connecting wires, and fixing accessories
Supply and erection of 12Watts, Round type Globe or circular pendent LED light fitting suspended from the ceiling with hanging supports, PVC unsheathed copper leads from terminals to the fitting . Similar to signify model Philips HDL 800051
Supply and erection of 26W LED Postop made up of aluminium pressure die-cast aluminum with polycarbonate cover in addition to a specific weathering resistance treatment, Bigger Dia of 338 mm helps for uniform light distribution & Polycarbonate cover for glare-free light distribution, PDC spigot helps in sturdiness of product, Smooth finish Top cover, Robust Mounting base & Direct the light where it is needed to avoid sky pollution. High Efficiency long life LED module with SMD LED package mounted on MCPCB. Lumen Efficacy of LED>100Lm/W and CRI >70. Powered by Built In electronic. LED driver with THD<10%, 4kV inbuilt surge protection, high cut off at 325V, LV cut-off & HV Protection@440V for 8 hrs. System Lumen>4500 Lm, IP 65, IK 05, PF>0.95, Operating voltage range: 140 V - 270V, Average life L70B50: 50,000 hours. Both the fixture and Driver should be of same make & must have separate BIS approval. Similar to Signify Cat. Ref. No. BGP200 LED26 CW PSU GR CPC SPD
Supply and installation of 3Watts EXIT / Toilet double sided signage LIGHT 180 min backup Prolite Autoglow IP44 or eqvt with cable, with all accessories
CABLE TRAYS Supply and erection of following size 2mm thick Ladder type, Pregalvanized, cable trays and cable tray of rolled GI Sheet, supports out sections, pipes, plates, etc. including welding, anchor bolts, threaded down rods(for 300 mm trays only), supply of necessary anchor bolts and grouting etc. including breaking walls, floors, etc. for structures as required including supply of all GI hardware materials, all labour and materials complete as per approved drawings, specifications of this tender and directions of Engineer-in-charge.The rate shall include supply & fixing of MS Grip bolts in columns/beams/walls/ceiling etc.as required & including drilling also. Rod supports shall be of galvanized full threaded rods of sizes 8,10 & 12mm dia for fixing to anchor fastener, anchor bolts.The length of the full threaded rods for the purposes of quoting shall be 1200 mm & includes nuts & washers and supports shall be at a min.distance of 1Mtr.The rate will include all required bends, tees, vertical up & downs, radius bends and other applicable accessories shall be factory fabricated, complete & as required. The rate shall inclusive of necessary theaded rods,nuts & bolts, making clamp in the Z perlin/Truss, cable tray clamps etc,(8 mm threaded rod shall be provided at every alternative purlin appx. 2 mtr length)
750 x 50mm x 2mm GI Ladder type cable tray
600 x 50mm x 2mm GI Ladder type cable tray
450 x 50mm x 2mm GI Ladder type cable tray
300 x 50mm x 2mm GI Ladder type cable tray
150 x 50mm x 2mm GI Ladder type cable tray
Supply and fixing of GI Perforated Cable tray with horizontal and vertical bends, reducers, Tee's, cross over, suitable supports and brackets and other accessories as required confirming to IEC-61537. The Tray shall be galvanized for corrosion protection confirming to DIN EN 10346 / ISO 1461 .The trays should be tested for a safe working load of 150 Kgs with a span distance of 1.5 meters and the deflection should be within the limits as per standard. The safety factor shall be 1.7 times of the safe working load. The rate shall inclusive of necessary theaded rods,nuts & bolts, making clamp in the Z perlin/Truss, cable tray clamps etc, (8 mm threaded rod shall be provided at every alternative appx. 2 mtr length)
450 x 50mm x 1.6mm GI Perforated type cable tray
300 x 50mm x 1.6mm GI Perforated type cable tray
150 x 50mm x 1.6mm GI Perforated type cable tray
100 x 50mm x 1.6mm GI Perforated type cable tray
1.2mm Thickness GI Cover for the above cable trays
EMERGENCY LIGHTING UPS:
STREET LIGHTING -- MAIN ROADS The rate includes excavation and foundation for erecting the referred street light pole as required at site and inclusive of necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same. each arm with light- The pole shall be grouted inside ground pit (cross section 600 x 600 mm) with cement concrete 1:2:4 with necessary GI ‘A’ class pipes (not less than 38 mm dia, NB) to facilitate pulling of cables. Separate pipes shall be provided for incoming and outgoing cables. The cement concrete shall be protected from premature drying by curing for at least seven days after pouring. All concrete surfaces from 150 mm below ground level to top shall be finished smooth with cement mortar 1:4.
SINGLE ARM POLE: Supply and erection of GI octagonal pole with GI bracket.Height of Pole 7Mtrs. above ground level with necessary long bracket including providing necessary base plate fixing arrangements, concealed type JB for accommodating DP MCB & connector including wiring to the light fittings with 3C x 2.5 Sq.mm copper flexible cable, etc., The rate shall included for cable in and out through 40mm dia PVC Conduits. Note:- The rate quoted for complete set of Pole with foundation bolt nuts, internal wiring, 6A DP MCB and all necessary accessories, etc., Including Civil works
DOUBLE ARM POLE: Supply and erection of GI octagonal pole with GI bracket.Height of Pole 7Mtrs. above ground level with necessary long bracket including providing necessary base plate fixing arrangements, concealed type JB for accommodating DP MCB & connector including wiring to the light fittings with 3C x 2.5 Sq.mm copper flexible cable, etc., The rate shall included for cable in and out through 40mm dia PVC Conduits. Note:- The rate quoted for complete set of Pole with foundation bolt nuts, internal wiring, 6A DP MCB and all necessary accessories, etc., Including Civil works
Supply, erection, testing & commissioning of 120W Watts LED street light luminaire with epoxy powder coated pressure die-cast aluminium housing with heat resistant toughened clear glass fixed with SS screws. with operating voltage range (140 - 310V AC). The luminaire shall be minimum IP66 protected. The LED driver has protection against over voltage and short circuit with LED driver efficiency should be greater than 85% with CRI greater than 75 and with colour temperature 5700K range. The LED having 50,000 burning hours with minimum 80% lumen maintenance & PF is 0.95 with THD less than 15%.
Facade Lighting: Supply and erection of plinth / peripheral wall / Pole mounted 100W weather proof FLOOD LIGHT with necessary DRIVER etc. all complete for enlightens the elevation of the building. The scope includes construction of necessary plinth to the required height of Architect / Consultants and all other connected civil / other such work. The scope also includes providing necessary mounting brackets, lamp pilferage arrangement etc. to the satisfaction of the Architects / Building Managers.Assymmetical flood light fitting with IP65 rated Cable junction box
Supply and erection of entrance gate light 28Watts LED Light fitting of IP65 rated with IP65 rated Cable junction box and all the fixing accessories
MISCELLANEOUS ITEMS
Supply and providing of 6mm thick MS Chequered Plates as floor separators for covering the shafts with angle iron supports at floor level to form a complete fire barrier protection between two floors and to cover the gaps around the cable trench etc., in the duct.
Supply, fabrication and erection of MS structural steel including 2 coats of red oxide primer & 2 coats of approved enamel paint including all channels and angles, suspension supports, steel plate, anchor bolts, cross angles, brackets, etc. including grouting, welding, tools, tackles as required etc. The payment shall be made for the actual quantities measured. This item shall be operated for tray supports in cable trenches, cable trays, Mounting frames for panels, DBs, vertical tray supports, busduct supports
Liaison with the Chief Electrical Inspector to Govt., /CEA for preparation of Working drawings etc., obtaining approval for drawing.Preparation of completion Report, Arranging for Inspection and attending to defects report and preparation of as fitted drawings and obtaining Safety Certificate from CEIG /CEA for commissioning. Liaison with the Chief Electrical Inspector to Govt., for issue of Safety certificate approval for energisation. clearance from SUPPLIER including for installation and running DG set.The works executed as built drawings need to be submitted in the blue print of A1 size in 4 Sets of hard copy and two set sets of soft copy in CD.The necessary statutory fees/charges will be paid by the client against demand advice.
LIGHTINING PROTECTION SYSTEM:
Supply and laying ''of 8mm dia Aluminium alloy Solid Round Conductor of material AlMgSi used in air termination system . Cross sectional area of conductor should be 50 mm². Test Parameter: a.Lightning impulse current of 100kA for 10/350 µs b.Electrical resistivity - 0.034 µΩm, c.Tensile strength - 178 MPa or N/mm² d. Salt spray - No Sign of Corrosion. Tested as per IEC 62561-2. CAPE Type: SRC 8–AL (Article No. 400 008)
Supply and installation of Polyamide Conductor holder for Parapet wall for holding 8 mm dia Aluminium alloy round Conductor. CAPE Type: PCH 8-L (Article No. 440 006)
Supply and installation of Polyamide Conductor holder for flat roof with concrete block for fixing 8 mm dia Aluminium alloy Solid Round Conductor in the terrace flat surface at every 1 mtr. CAPE Type: MBPCH 8-L (Article No. 440 006)
Supply and installation of Stainless steel 304 Grade Cross Connector for 8mm dia Aluminium alloy round conductor & 10 mm Copper bonded conductor at cross/Tee junction. Test Parameter a) Mechanical Load b) Electrical Test c) ENvironmental Test Tested for IEC 62561-1. CAPE Type: CCSS 8-10 (Article No. 400 206)
Supply and installation of Expansion Joint with connector to compensate the expansion and contraction of Solid Round Al. Conductor during temperature variations. Expansion Joint should be consider at every 20 mtr length of straight horizontal air termination and connected at both the end with use of straight connector conductor. CAPE Type: EPC 8 (Article No. 401 209)
Supply and installation of Aluminium Straight conductor connector for interconnecting 8mm Aluminium conductor to meets the requirement of IS/IEC 62305. Test Parametres: a) Mechanical Load b) Electrical Resistivity c) Environmental Test Tested as per IEC 62561-1. CAPE Type: CJ 8 (Article No. 401 211)
Supply and installation of air termination rod of 3mtr length of material AlMgSi of diametre ø 16/10 mm crimped on both the ends (Tappered Type). The rod shall be mounted with stainless steel clamp and fixing accessories . Test Parameter for 3 mtr vertical air terminal a)ELectrical Resistivity b) Tensile Strength c) Condition of Salt Mist Tested as per IEC 62561-2. Test Parametrer for Wall clamp a) Mechanical load as per IEC 62561-1 CAPE Type: VATW3 (Article No. 405 420)
Supply and installation of Stainless steel SS 304 Grade Folding Clamp as per sheet profile for 8 mm dia Aluminium alloy Solid Round Conductor for horizontal Air terminal above metal sheet to meet the requirements for IS/IEC 62305. Test Parameter: a) Mechanical Load b) Environmental Test Tested as per IEC 62561-4 CAPE Type: FSCH 14-8 (Article No: 440 011)
DOWN CONDUCTOR SYSTEM
Supply and laying of 8mm dia Aluminium alloy Solid Round Conductor of material AlMgSi used in air termination system . Cross sectional area of conductor should be 50 mm². Test Parameter: a.Lightning impulse current of 100kA for 10/350 µs b.Electrical resistivity - 0.034 µΩm, c.Tensile strength - 178 MPa or N/mm² d. Salt spray - No Sign of Corrosion. Tested as per IEC 62561-2. CAPE Type: SRC 8–AL (Article No. 400 008)
Supply and installation of Polyamide Conductor holder for Parapet wall for holding 8 mm dia Aluminium alloy round Conductor. CAPE Type: PCH 8-L (Article No. 440 006)
Supply and installation of Aluminium Straight conductor connector for interconnecting 8mm Aluminium conductor to meets the requirement of IS/IEC 62305. Test Parametres: a) Mechanical Load b) Electrical Resistivity c) Environmental Test Tested as per IEC 62561-1 CAPE Type: CJ 8 (Article No. 401 211)
Supply and installation of Stainless Steel 304 grade Test Joint with enclosure to interconnect between 8 mm Al. round conductor to 10 mm copper bonded round conductor. Test Parameter: Salt Spray Test for test joint plate -No sign of Corrosion Tested as per IEC 62561-1 CAPE Type: TJRRE - G1 (Article No. 404 214)
Supply and installation of Lightning counter - LCD screen shows the number of lightning strikes, hour and date of lightning events Buttons enable TIME/DATE setting and log viewing. Replaceable battery, working life minimum five years, Complies with IEC/EN 62561-6. CAPE Type No: PRO LER (Article No. 400 999)
Supply and laying of 10 mm Copper bonded Steel Round Conductor 20 mtr length as integrated down conductor. Material should be tested Tensile strength, Electrical Resistance, salt mist, Bend & Adhesion to meet the requirements of IS/ IEC 62305 and IEC 62561-1&2. CAPE Type: SRC 10 CuB (Article No. 400 010)
Supply and installation of Stainless steel SS 304 Grade Conductor Holder for fixing the 8 -10 mm dia round conductor on the wall . Test Parameter: a) Mechanical Load b) Environmental Test Tested as per IEC 62561-4 CAPE Type: CH 8-10 (Article No. 400 213)
Supply and installation of UL Listed Maintenance Free Copper bonded Earth rod of 3048mm length having the dia of 14.2 mm with copper coating thickness of 254 microns. The rod has been tested for Dimension, Marking, Tensile Strength, Salt mist, coating thickness, Electrical resistivity test before and after corrosion test as per IEC 62561-2 & UL 467. CAPE Type : CBR 1410 (Article No. 300 010) Supply and installation of CAPE make earth enchancing mineral compound tested for leaching and TCLP with NABL accredited Lab as per IEC 62561-7 -25 kg. CAPE Type: PROSAN 12.5 (Article No. 300 830) Supply and fixing of CAPE make Earth rod clamp made for terminating cable / flat conductor. Supply and fixing of CAPE make Earth Chamber Inspection Pit made up of Plastic withstand load of 60kN
SOLAR PV SYSTEM
Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Monoperc PVC solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 550 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required- 30 KW SOLAR SYSTEM
550 Wp Solar PV Panels,Structure, Earthing, Wiring, and other accessories,Power Conditioning Unit(PCU) 25 kWp,3 PH INVERTER, CABLES, CARTAGE, INSTALLATION CHARGES , FASTNERS, CABLE TIE, CRIMPING TOOLS, EARTH KIT, 5years warranty for complete set, 25 year warranty for solar panel. a) Invertor : 6 In / 6 Out b) Reverse Power Protection Relay Panel c) 3 Compartment EB LT-CT Box d) Solar Panel : < 550Watts Mono Perc Bi-facial
Solar PV Modules — 550 Wp mono-PERC (Made in India, IEC/IS cert.)
Power Conditioning Unit / On-Grid Inverter (30 kW class)
Module mounting structure (GI/Alu rooftop, fixtures, clamps)
DC/Array & AC cables (XLPE armoured copper, glands, lugs)
Array Junction Boxes & Main Junction Box (IP65)
Surge Protection Device (AC & DC SPDs)
Earthing (earth pit, copper earth, bonding)
Data Monitoring System (IoT data logger + portal)
Labour — supply & installation
Testing & Commissioning, Net-metering assistance
Miscellaneous (civil supports, fasteners, consumables)
Charges towards preparation of drawings and getting approval from CEIG and TANGEDCO for 30kW Solar Power System, including site inspection, approval and safety certificate
DIESEL GENERATOR
Supply, Installation, testing and commissioning of 400KVA, Silent type Diesel Generator Sets complete with suitable size Acoustic enclosure Diesel Engine suitable for Generator application, developing 1500RPM with an overloading capacity of 10% for one hour in any 12 continuous hours operation generally confirms to BS:5514, directly coupled to 400KVA at 0.8 Power factor, 415V, 3Phase , 4wires, 50cycles per second self excited, self regulated, with brushless excitation, Alternator generally confirms to BS:5000/IS:4722. DG set shall be complete with radiator, residential type silencer, electronic governor, cable termination box, MS mounting frame, fuel piping, diesel day tank, 24VDC Battery, Battery mounting frame, oil level indicator with gauge board, and all other accessories as per specifications and schedule.
Diesel Generator set shall be mounted on cushy foot or similar type of vibration Isolators. The cost of Exhaust pipe shall be excluded in this item. The DG Set shall be suitable for auto-mains failure start and auto / manual operations. The cost shall include fuel oil required for testing DG Set at full load. The DG Should be supplied with Auto-Start-Stop Control panel with suitable rating switchgear.
Diesel Generator set shall be mounted on cushy foot or similar type of vibration Isolators. The cost of Exhaust pipe shall be excluded in this item. The DG Set shall be suitable for auto-mains failure start and auto / manual operations. The cost shall include fuel oil required for testing DG Set at full load. The DG Should be supplied with standard Control panel with suitable rating switchgear.
Design, manufacture, supply, installation, testing and commissioning of DG Synchronising Panel for 2 x 400KVA DG Set with all the accessories and as per the SLD
Design, manufacture, supply, installation, testing and commissioning of 8" (inch) dia MS exhaust pipe class B suitable for 400KVA engine exhaust line (Vertical) including with all accessories such as bends,.flanges, gaskets, condensation removal plug, fixing of flexible coupling, residential silencer supplied along with the engine. Providing necessary MS angle iron supports for the pipe line and the silencer, welding arrangements/ flanged joints with bolts/nuts as per the site conditions. Terminating the pipe line in duct /shaft including the complete insulation with 50mm thick glass wool, polythene covering, chicken mesh and aluminium cladding complete as per the specifications etc. as required.
Design, Manufacture,Supply, Installation, Testing and Commissioning of the Exhaust Stack suitable for 1 x 400 KVA DG set with exhaust gas flow with wind pressure suitable for LOCAL condition and exhaust gas velocity, necessary stiffner rings & flanges, sampling ports, foundation bolts, lightning arrestor, earth strip of 25 x 6mm GI for Earthing stack and LA, insulators, foundation bolts etc. Design data should be furnished for wind pressure, base diameter and thickness of plate at cone and shaft areas. The rate shall include Lightning Protection, aviation warning lamp( LED type) with photo cell including cabling, termination, control MCB etc. The rate shall include necessary steel structure including necessary supports, Scaffolding charges, necessary bellows etc.,. Exhaust Pipe including necessary painting. The Exhaust stack height will be 10 Mtrs. DG sets to be provided for 1 x 400 kVA End of the Exhaust stack shall be design shaped to protect & to avoid rain water entry inside pipe and bended towards wind flow direction at LOCAL condition etc,.
Supply, fixing, testing and commissioning of the Residential silencer for the 400KVA Prime Duty DG set with complete insulation covering with 50mm thick glass wool, polythene covering, chicken mesh and aluminium cladding complete as per the specifications etc. as required.
Supply and erection of 25 mm dia, Class 'B' MS pipe for the interconnection of the Day fuel tank with the engines, with necessary welding, jointing and painting etc.,
Supplyng and laying of the following PVC insulated, PVC sheathed armoured Copper conductor cabling from engine control panel to battery charger, day tank with suitable clamping arrangement, end terminations, earthing the glands, laying on the existing cable tray /trench, painting complete etc. as required.
16 C x 2.5 sq.mm PVC insulated Copper cable
4C x 2.5 sq.mm PVC insulated Copper cable
4C x 1.5 sq.mm PVC insulated Copper cable
1.5 sqmm PVC insulated Copper cable Screened communciation cable
EV CHARGING STATIONS:
Supply Installation testing and Commisioning of 60W EV Charger : ITEM CODE - OEV60K-2DCCS-LSC
Supply of CCS-2 + CCS-2 DC FAST EV CHARGER 60KW (Dual Gun) (200- 1000V DC)
Input Voltage(AC) : 3 Phase, 415 Vac(374~440Vac) Input Frequency : 50±1Hz
Wire Connections : 5 (L1,L2,L3,N,PE) Number of Outputs: 2 Nos.
Output Connector : 30 kW CCS-2 + 30 kW CCS-2 (Max @ 30 kW/ Output)
Output Rating: 60kw
Display: 7" TFT LCD with touch User Authentication: RFID Based
Charger and CMS: Protocol: OCPP 1.6 (Open Charge Point Protocol)
Interface: Ethernet/4G/WiFi Wire Length: 7m
Ambient Temperature: -20⁰C to 55⁰C Storage Temperature: -20⁰C to 70⁰C Altitude: <2000Mtr
Humidity: <95%, Non-Condensing Ingress Protection: IP54
Cooling: Forced Fan Air
Installation charges
Commissioning Charges/Unit
LUBI CMS Software Integration- One time
LUBI CMS Subscription 1 year
Supply, Installation, Testing and Commission of the 10KW EV Charger. ITEM CODE - LEVBAC001-10KD4G
Bharat charger (BEVC-AC001)10 kW
Input Voltage(AC) : 3 Phase, 415 Vac(374~440Vac) as per IS 12360 A.C
Input Frequency : 50±1Hz
Wire Connection : 5 (L1,L2,L3,N,PE) Number of Outputs : 3.3 kW x 3
Output Connector : IEC 60309 Industrial/ Domestic 3 Pin Socket Output Current : 15A
Ambient Temperature : -20⁰C to 55⁰C Storage Temperature : -20⁰C to 70⁰C Altitude : <2000Mtr
Humidity : <95%, Non-Condensing Display :
Installation Charges
Supply and fixing of supporting metal frame work for the 10 KW charger Panel
Commissioning Charges/Unit
LUBI CMS Software Integration- One time
LUBI CMS Subscription 1 year
SEWERAGE & RAIN WATER HARVESTING
EXTERNAL SEWERAGE
Supplying and Constructing Sewage collection sump I Well as per the following sewage holding capacity (after invert level of pipe - with a free board of mkinimum 750mm) including making earth work excavation, laying cement concrete in 1: 3: 6 mix for 250mm depth in foundation, providing and laying in position machine batched, machine mixed and machine vibrated design mix concrete of M25 grade RCC by using not less than 410 kg of cement and 250 kg of steel per cubic metre of concrete (sizes of structural members such as base slab side walls and cover slab shall be designed by the Contractor after making necessary site visits and studying the conditions at site and adopted after getting approval from the Engineer-in-charge), including finishing by plastering with cement mortar 1:3 mix for inner surfaces, plastering outer surfaces in cement mortar 1:4 mix, 20mm thick,fixing and removing form work for shuttering to RCC works, providing and fixing two number of SFRC manhole cover and frame 600 x 600 size weighing 50 kg, 1No of 1200 x 1200mm size pre fabricated metal cover and frame (gas and water tight) with painting, suitable size screen made of stainless steel bars & plates as per the standard drawings, refilling the sides with excavated earth,disposing surplus earth with in the Site,bailing out the water from the excavation, conducting water test for leak proof construction by filling water to full depth of collecting well etc., Collection tank Size LxWxH 2000x1500x2000 mm
Supplying & Construction of inspection chambers of following sizes 60 x 60 x 60cm with earth work excavation for foundation, 23cm thick concrete bed using 40mm brick jelly concrete in C.M.1:5:10 for foundation, brick work in C.M.1:6 for chamber, plastering with C.M.1:3, 12mm thick, benching, channelling, supplying and fixing 45x45cm FRC cover and frame, etc.,
Supply and fixing of conical manhole with 230 mm best quality approved table moulded bricks in CM 1:6, 560 mm dia at top and 900 mm dia at bottom over a bed of 250 mm thick PCC 1:4:8 walls plastered inside smooth in CM 1:3 and outside in CM 1:6, necessary excavation for the manhole in all sorts of soil including soft and hard rock, benching and channelling in PCC 1:2:4 as per drawing supply and fixing of frame and cover AAGMA make, CI steps etc., a) Depth of manhole 0.9 m to 1.65 mtrs
Supplying, fixing, testing and commissioning of ready made PVC gully trap (ISI brand only) of 300 x 300 mm size with 75 mm dia outlet. and also providing suitable size of cast iron grating, including 40 mm thick precast ready made light duty RCC cover slab, clearing the surplus material, earth etc., a) 300mm x 300mm size `P/S' trap
Supplying and fixing SFRC manhole covers with frame (With holes) of following size confirming to IS 12592-HD20 Grade with clear opening size of 600 mm. The rate shall be inclusive of fixing frame with cement concrete, finishing, cost of materials, labour, tools & plant, curing, consumables, leads and lifts at all levels, loading and unloading charges, transportation, all other incidental charges, providing provision for locking arrangement, etc. complete as per specification, drawing and as directed by Engineer-in-charge. The rates of cement concrete for fixing frame with necessary finishing shall be paid for separately under respective item a) 600mm X 600mm Heavy duty
Supplying and fixing CI manhole covers of approved size and make. The rate shall be inclusive of providing locking arrangement, finishing the surface with 2 coats of approved Zinc chromate primer and 2coats synthetic enamel paint of approved manufacture and color as per the specifications, fixing edge angle of size 40x40x5mm all-round the opening in cement concrete with necessary finishing, cost of materials, labour, tools & plant, curing, consumables, leads and lifts at all levels, loading and unloading charges, transportation, all other incidental charges, etc. complete and as directed by Engineer-in-charge. a) Heavy Duty - weight of cover not less than 110 kg of 600X600mm size
Supplying and Installation of 300mm dia. RCC Hume pipes with collars for road / below floor crossing of Fire water pipes. Rate shall include PCC ( 1:4:8 100 mm thick)bed and ends shall be closed with Brick masonry work as directed by site engineers.
80 mm dia uPVC pipe
150 mm dia uPVC pipe
SANITARY FITTINGS
Supplying and fixing in position White / Colour Special Delux Model Glazed Cascade Type Parryware / Hindware / Equivalent Wall Mounted European Water Closet of best quality and approved make with 100mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, union coupling connected by means of 40mm white PVC flush hand using indian adopter joint including all internal fittings, such as, 15mm bras connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) with 10 litres capacity flushing tank with all internal dual flush fittings with normal seat cover Wall Fitting
Supplying and fixing of White Glazed Porcelain Oval Shape Special Type Urinal of size 382 x 398 x 601mm
Supplying, installing, of granite (Jet Black) Urinal partition size 750mm x500 mm with 20mm thick of approved colour ''Pre polished both sides and edges made to shape as per drawing, fixing with S.S ''U'' clamp and bolt,nut to wall complete etc.
Supplying & installing Wash Hand Basin of size 550mm x 400mm with all accessories such as Cast Iron Brackets, 32mm dia CP Waste Coupling, Rubber Plug and Chain, 32mm dia ‘B’ Class GI Waste Pipe, 15mm dia GM Wheel Valve, 15mm dia Nylon Connection, 15mm dia Brass Nipples, 15mm CP Pillar Tap etc
Supply, Fixing and testing of 15mm Stainless Steel Health faucet of approved make with necessary flexible hose 1000 mm long nozzle, wall flange etc., complete.
Supplying, installing, testing and commissioning of CP exposed type Toilet paper holder with necessary screws etc., Paper Holder Make -TOTO / Kohler / Jaguar
Supply, Fixing, testing and commissioning of 15 mm dia C.P. brass 2 way cock with C.P. wall flange of approved quality and making good as required.
Supplying,installing, testing and commissioning of cp Double Coat hook fixing with necessary screws etc., complete
Supplying, installing, testing and commissioning of liquid soap container of approved make near wash basins with necessary fixing screws and clamps etc., Deals Stainless Steel Long Cylindrical Soap Make -TOTO / Kohler / Jaguar
Supply and fixing of Hand drier of approved make and colour having twin blower integrated with timer cum infrared sensing system fully automatic which can work on 230 volts, single phase, 50 cycles etc., High Speed Hand Dryer
Supplying, Installing, testing and commissioning of White color Floor Mounted European water closet with inbuilt low level PVC flushing cistern and Wash Basin for Physically Challenged Persons (Matrix) with necessary Grab Rails, hinged rails for support , pan connecter bend,checknut, stopcock etc., colour solid seat and cover with polythene buffer and flap, CP flanges, CP bolts and nuts, bracket with nuts and bolts wall flanges etc., complete, Wash Basin shall include 15mm dia CP liver operated pillar Cock / auto closing pillar tap with waste coupling, 32mm dia CP bottle trap with extension pipe, supporting bracket with necessary steel to support basin 1 No.15mm CP angle valve with 450mm long CP connection pipe and CP wall flanges all of approved make etc., complete.
Close Coupled Toilet ( P Trap ) + Two Piece Toilet With Tank Lavatory 1 Tap Hole (for The Disabled Flip up Type Grab Bar w/ Lock T113HK7 Straight Grab Rail - 600mm - Dia 34mm T113B6 L Shaped Grab Bar Fixing Bolt (Set) Single lever lavatory faucet Waste Coupling& CP bottle trap Make -TOTO / Kohler / Jaguar
Supplying, installing, testing and commissioning of Soap dish holder of approved make near shower with necessary fixing screws and clamps etc., complete.
Supplying, installing, testing and commissioning of 600mm x 600mm x 200mm stainless steel sink with Single bowl single drain of approved size manufactured from 1mm thick stainless steel, 18 G high grade indestructible chrome nickel steel with top quality polish, 40 mm dia CP waste coupling with extension flexible pipe of suitable dia. 15 mm dia angle cock, TEE joint with threated dummy, etc., complete. Supply and fixing of granite counter shall be done by the civil contractor
Supplying, installing, testing and commissioning of SS Modular wall mounted Drinking water dispenser (Fountain –Hot & cold both) of approved make at toilet core with necessary accessories and supporting screws and clamps etc.,
Supplying and fixing Grab bar 450mm Long with necessary fixing accessories
Supplying and fixing Special Type Mirror of size 1000 x 780mm
INTERNAL DRAINAGE
Supplying, fixing and testing UPVC SWR- B Class pipe of approved Make confirming to IS 13592-1992. and fittings confirming to IS 14735-1999, such as coupler, elbow, bends, Tee, Y, vent cowl etc for Soil, Waste, vent and rain water pipe works in shaft and suspended in ceiling., laid in ground( from shaft to Inspection chamber and Gully chamber), etc., using rubber ring joints(rubber ring confirming to IS 15382) for shafts lines and solvent cement joints for suspended lines and work in below ground. Woks includes necessary scaffolding, cutting and making good the walls wherever required all complete as directed by Engineer.
100 mm dia uPVC pipe
80 mm dia uPVC pipe
40 mm dia uPVC pipe
Supplying, fixing and testing of UPVC/ PVC floor trap with cockroach trap and CP grating 150 mm nominal size square 100mm diameter of the inner hinged round grating various inlet from 40 dia to 110 dia and various outlet from 75 dia to 100 dia with the extension pipe, boss tee connections, fixed in sunken floors /Suspended support with ceiling level etc.,
Supplying, fixing and testing of UPVC floor clean out used in sunken floors,75 & 110mm dia with extension pipes,specils such as 45 degree bend , tee ,CP tile grating and end cap (clean out plug ).the cap arrangements with female thread fix with the upvc clean out plug in male thread with gasket and s.s screws etc. complete. Works including cutting and making good the walls /floor wherever required, etc., complete.
110 mm dia
75 mm dia
Supplying, fixing and testing of UPVC urinal trap with CP anti foul drainer square cockroach trap, 150 mm nominal size square 100mm diameter of the inner hinged round grating various inlet from 40 dia to 110 dia and various outlet from 75 dia to 100 dia with the extension pipe, boss tee connections, fixed in sunken floors /Suspended support with ceiling level etc., complete. Works including cutting and making good the walls /floor wherever required, etc., complete.
INTERNAL WATER SUPPLY
Supplying, installing testing and commissioning of approved make chlorinated polyvinyl chloride pipe (CPVC) up to 50 mm dia SDR 11 ASTM CTS and above 50mm dia CPVC schedule 80 fittings. The fittings and specials such as tees, elbow, coupler, bends, enlarged etc., with CPVC brass thread combination /transition specials such as male adapters brass threaded female adopters, brass FPT tee, brass FPT elbow etc., where connection with metal is to be made including necessary hole drilling holes chasing wall and making the same good in cement mortar 1:1 restore the same original condition neatly as directed by the engineer in charge. Joint to be made with CPVC solvent cement up to 50mm dia as per ASTM D-2846 and above 50 mm dia primer P-70 and solvent conforming to ASTM F- 4931 / 724 the rate shall be inclusive of all necessary suspended support and wall support with suitable brackets clamp and bolt nut etc complete.
25mm nominal outer dia. Pipe
25mm nominal outer dia. Pipe
32mm nominal outer dia. Pipe
40mm nominal outer dia. Pipe
50mm nominal outer dia. Pipe
65mm nominal outer dia. Pipe
Supplying, installing, testing and commissioning approved make lever operated forged brass / Bronze Ball valves conforming to BIS/BS with brass body forged brass hard chrome plated steel ball tested to a pressure rating not less than 15 Kg / sqcm with threaded / flanged joints with nuts, bolts, gaskets, washers union etc complete .
25 mm nominal bore
32 mm nominal bore
40 mm nominal bore
50 mm nominal bore
Supply & Fixing in position control lever operated type PN 10 CI body butterfly valve with matching CPVC companion flanges asper table -'E',SS bolts, nuts, nitrile rubber gasket with necessary fittings etc., 65mm dia (Flange end)
Supplying &installing, Chrome plated forged brass body and cover Auto Air release valve for domestic and flushing water supply risers, suitable for pressure not less than 15 Kg/Sq.cm. a) 25 mm nominal bore
Supplying, installing, testing & commissioning approved make forged brass Pressure reducing valve (PRV) with all accessories conforming to IS/BS with unions etc., a) 32 mm nominal bore
Supply & Fixing PN 16 CI Y strainers with perforated brass strainer body of approved make, provide each strainer with a cock for blowing down. Screen area of strainer shall be minimum of 5 times more than the pipe area with 1/32 inch max size holes. The cost also includes necessary fittings for supply and fixing to the pipes. a) 50mm dia (Screwed end)
Supply & Fixing Check valves. The body and plates are of CI body and pressure rating is PN 16. The valve seal is Neoprene rubber. The cost also includes necessary fittings to complete the connections. Please refer technical specification attached. with necessary fittings etc., complete 50mm dia (Screwed end)
RAIN WATER HARVESTING
Supply & Fixing of (DWC HDPE) Double wall corrugated high density polyethylene ISO 21138-Part-1 & 3,EN 13476-1 & 3 soil, waste & all necessary specials like bends, tees, etc., laid under ground with necessary fittings etc., complete. For Under ground drainage system a) 160mm OD -SN8
Supply & Fixing Class II (6 kg/cm2) rigid PVC pipes (for rain water down takes) with necessary specials like bend, shoe, grating, clamps, screws etc., including jointing the pipes and specials with solvent cement and cutting the pipes required lengths, with necessary fittings etc., complete at all heights and depths. a) 110mm OD
Supplying & Construction of inspection chambers of following sizes 60 x 60 x 60cm with earth work excavation for foundation, 23cm thick concrete bed using 40mm brick jelly concrete in C.M.1:4:10 for foundation, brick work in C.M.1:6 for chamber, plastering with C.M.1:3, 12mm thick, benching, channelling, supplying and fixing 45x45cm FRC cover and frame, etc.,
Supplying and fixing SFRC manhole covers with frame (With holes) of following size confirming to IS 12592-HD20 Grade with clear opening size of 600 mm. The rate shall be inclusive of fixing frame with cement concrete, finishing, cost of materials, labour, tools & plant, curing, consumables, leads and lifts at all levels, loading and unloading charges, transportation, all other incidental charges, providing provision for locking arrangement, etc. complete as per specification, drawing and as directed by Engineer-in-charge. The rates of cement concrete for fixing frame with necessary finishing shall be paid for separately under respective item a) 600mm X 600mm Heavy duty
Supplying and fixing CI manhole covers of approved size and make. The rate shall be inclusive of providing locking arrangement, finishing the surface with 2 coats of approved Zinc chromate primer and 2coats synthetic enamel paint of approved manufacture and color as per the specifications, fixing edge angle of size 40x40x5mm all-round the opening in cement concrete with necessary finishing, cost of materials, labour, tools & plant, curing, consumables, leads and lifts at all levels, loading and unloading charges, transportation, all other incidental charges, etc. complete and as directed by Engineer-in-charge. a) Heavy Duty - weight of cover not less than 110 kg of 600X600mm size
Supplying and Constructing Rain water collection sump I Well as per the following sewage holding capacity (after invert level of pipe - with a free board of minimum 750mm) including making earth work excavation, laying cement concrete in 1: 3: 6 mix for 250mm depth in foundation, providing and laying in position machine batched, machine mixed and machine vibrated design mix concrete of M25 grade RCC by using not less than 410 kg of cement and 250 kg of steel per cubic metre of concrete (sizes of structural members such as base slab side walls and cover slab shall be designed by the Contractor after making necessary site visits and studying the conditions at site and adopted after getting approval from the Engineer-in-charge), including finishing by plastering with cement mortar 1:3 mix for inner surfaces, plastering outer surfaces in cement mortar 1:4 mix, 20mm thick, fixing and removing form work for shuttering to RCC works, providing and fixing two number of SFRC manhole cover and frame 600 x 600 size weighing 50 kg, 1No of 1200 x 1200mm size pre fabricated metal cover and frame (gas and water tight) with painting, suitable size screen made of stainless steel bars & plates as per the standard drawings, refilling the sides with excavated earth, disposing surplus earth with in the Site, bailing out the water from the excavation, conducting water test for leak proof construction by filling water to full depth of collecting well etc. a) Collection tank Size LxWxH 2000x1.500x2000 mm
Supply & Fixing PVC rain water Khurra, flashing including moulded bends, enlarger & leaf trap complete at each outlet. etc., Side outlet 110 mm OD
Supplying and installation of Precast Concrete Trench with top cover (900 X 800 mm)
Supplying, fabricating and erection of MS fabricated structural steel with 2 coats of red oxide primer & 2 coats of approved enamel paint (Total DFT minimum 120 micron) including all channels, box section, suspension supports, steel plate, cross angles, brackets, GI fasteners, anchor fasteners etc. including grouting, welding, tools, tackles as required etc.
PUMPS & WATER TREATMENT PLANT
Supply and installation of Electric Monoset centrifugal pump conforming to IS 9079:2002 as amended from time to time, with CI FG 200 Casing , hydraulically and dynamically balanced Bronze grade LTB-2 impeller, impeller ring and casing ring, stainless steel shaft capable of discharging required quantity of water against a total head noted below due to all causes. Pump shall of BEE 3 Star Rated and capable of discharging the specified quantity at the head noted at the minimum NPSHA at site conditions. The shut off head shall be at least 25% over and above the head at duty point. The pump shall be suitable for operation in AC three phase , 415 V+/- 10% , 50 Hz +/- 5%. Squirrel cage induction motor for continuous operation. The speed of the Pump and Motor shall be not less than 2700 to 2900 RPM respectively. Treated Water Pump (From Domestic Water Sump to O.H.T) Duty of Pump : 250 lpm x35m head (1 No. Working + 1 No. Standby)
Supply and installation of clear water vertical wet type submersible pump conforming to IS 8034/2002 and as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continuous rated two pole suitable wet type vertical squirrel cage induction motor suitable for operation in AC single phase 230 V+/- 10 %,50 HZ +/-5 % Pumproom drain pump Duty of Pump : 15lpm x 40m head (1 No. Working )
Supplying, Installing, testing & commissioning approved make variable Hydropneumatics system comprising of Vertical Centrifugal pumps mounted on a common skid with automatic control panel including overload relays, on-off push button switches, phase indicator lamps, dry run protection relays, pressure switches & gauges, 1no. FRP pressure vessel of 425Lts. mounted on the pump complete with cabling between the Pumps, control panel etc., complete. The pumps shall run on 440V, 3ph, 50Hz electric supply. (For flushing & landscaping water supply system) Duty of Pump : 67 lpm @ 45.0m Head Each Pump capacity 67 lpm - 2 pump system (1Working+1 Standby)
Supply, Installation & Commissioning of rain water monobloc type pump of adequate HP capable of giving required discharge at suitable head to work on 3phase 50Hz 400/400 V with necessary unions, flanges, foundations bolts etc., complete with head conditions. (1W+1S)
WATER TREATMENT PLANT 14.50 KLD (Capacity 2500 LPH) IN PUMPROOM
Supplying, Installing, testing & commissioning of Water Treatment Plant (WTP_ of 2500LPH capacity comprising of below units Filter Feed Pump 1 no. - Horizontal Monobloc centrifugal pump Capacity: 2500LPH Head 25m Make: Kirloskar/EQ Pressure Sand Filter 1 no.- Size: 12”x 52” MOC: FRP with 25 NB Multiport valve Filtering media : Pebbles, Sand Operating Pressure : 3 Kg/Cm2 Make : Pentair/Aventura Hypo Dosing tank 1 no.- Capacity: 50 Ltr. MOC: HDPE Make: Cantax / EQ Hypo Dosing Pumps 1 no. - Capacity: 0-4 LPH Make: Veritose/EQ Activated Carbon filter 1 no. - Size: 12”x 52” MOC: FRP with 25 NB Multiport valve Filtering media : Pebbles, Carbon Operating Pressure : 3 Kg/Cm2 Make : Pentair/Aventura Softener filter 1 no. - Size: 16”x 65” MOC: FRP with 25 NB Multiport valve, Filtering media : Resin OBR once in 8 hrs Operating Pressure : 3 Kg/Cm2 Make : Pentair/Aventura Regeneration tank 1 no. - Capacity : 50 litre Make : Cantex UPVC Pipes and Fittings As per requirement Make : Astral/Price/Supreme Starter, Cable, and accessories - As per requirement
RO WATER TREATMENT CAPACITY 250 LPH (1,000 Litre Storage) at Terrace
SEWAGE TREATMENT PLANT (STP - 25KLD)- (Incluiding Flow Meter)
Supplying, installation, testing and commissioning of STP ELECTRO-MECHANICAL EQUIPMENTS (Incluiding Flow Meter) (Capacity 25 KLD - MBBR TYPE) Parameters : Quality of Raw Sewage in Mg/l COD ≤ 600 SS ≤ 300 BOD ≤ 400 pH - 6 to 8, Treated Water standard achieved by the STP process in Mg/l COD ≤ 150 SS ≤ 20 BOD ≤ 20 pH - 6.5 to 8, Raw Sewage Source - STP Supplying, installing, testing and commissioning of Bar screen - 1 no. Type: Manual type MOC: SS 304, Raw Sewage Transfer Pumps - 2nos. ( 1 working + 1 stand by) Type: Submersible pump MOC: CI Make: Kirloskar/CG/EQ Power: 2.0 HP Raw Sewage Transfer Pumps - 2nos. ( 1 working + 1 stand by) Type: Submersible pump MOC: CI Make: Kirloskar/CG/EQ Power: 2.0 HP Aeration tank - 1 no. Volume: 6000 Liters MOC: FRP. Settling cum Intermediate Tank - 1 no. Volume: 3400 Liters MOC: FRP Settling cum Intermediate Tank - 1no. Volume: 3400 Liters MOC: FRP Sludge Recirculation Pumps - 1 no. Type: Self Priming pump Power: 0.5 HP Make: Kirloskar/EQ Air Blower with motor - 2nos. ( 1 working + 1 stand by) Air flow: 30 m3/hr Make: Airvak/EQ Diffuser - Coarse 1 Lot Type: Disc Air flow: 6 m3/hr (80mm dia) MOC: EPDM Diffuser – Fine for Aeration tank – 1 Lot Type: Fine Bubbl, Air flow: 6 m3/hr (63mmx610mm), MOC: EPDM, Make: Proflex/EQ Chlorine Dosing Pumps - 2nos. ( 1 working + 1 stand by) Capacity : 0-4 LPH @4 Kg/cm2, MOC: PP, Make: Edose/EQ Dosing Tank - 1 no. Capacity:50Ltrs,MOC:LDPE Filter Feed Pumps - 2nos. ( 1 working + 1 standby)
Supplying, installation, testing and commissioning of Monobloc pump Power: 1.0 HP Make: Kirloskar/ EQ Pressure sand filter with sand media - 1 no Model No.: 12 x 54, MOC: FRP with media and MPV, Make: Fibro Tech /Pentair/EQ Diffuser – Fine for Aeration tank – 1 Lot Type: Fine Bubble, Air flow: 6 m3/hr (63mmx610mm), MOC: EPDM, Make: Proflex/EQ Activated carbon filter with media - 1 no Model No.: 12 x 54 MOC: FRP with media and MPV Make: Fibro Tech /Pentair/EQ Bacterial bio culture 1 Lot [patented] Bio balls [Patented] - 1 Lot MOC: PP MS Structure 1 Lot Make: Shank/EQ Air Piping 1 Lot MOC: MS Make: Jindal Pipes / Tata/EQ Pipes & fittings - 1 Lot MOC: UPVC Make: Finolex / Astral/EQ Valves & Accessories - 1 Lot Make: Orbit/EQ Launder for settling tank 1 No. MOC : FRP Parallel plate[Patented] 1 Lot MOC : PVC Electromagnetic flow meter 2 Nos. Make : Aster /EQ at STP inlet & outlet
AIR CONDITIONING AND MECHANICAL WORKS (ACMW)
Supplying, installation, testing and commissioning of VRF Outdoor units consists of 100% inverter scroll compressor / Twin Rotary compressors, DC fan motor with aero-spiral fan blade, e-pass heat exchanger, safety valves, solenoid valves, receiver, capillary tube, check valve, electronic expansion valve, high pressure switch, low pressure sensor, pressure regulating valve, refrigerant filter, stop valve, accumulator, oil pre charging, vibration isolators, supports,elbow duct/cowl piece (If necessary), The VRF ODU shall be compatible for BMS integration.
The below mentioned ODU capacities are the minimum Cooling Capacity required at the following conditions a. 100% load condition b. 42 degC ambient condition designed and upto 48 DegC system should run without tripping c. All IDUs are in operating condition d. Design indoor temperature - Office area : 23 degC. RH shall not exceed 60%. The vendor to propose the suitable ODU considering the ambient deration. The VRF data sheet & ISEER data sheet shall be filled and submitted by the Vendor with the proposed VRF ODU capacity. The proposed VRF ODU capacity shall be approved by Client & Consultant before procurement.
Below Mentioned more than 20 HP ODU Models should be able to make module combination
(Approved Makes : Daikin,Hitachi,Carrier,Toshibha, Mitshubishi)
8 HP VRF ODU M-2035
10 HP VRF ODU M-2034
12 HP VRF ODU M-2033
16 HP VRF ODU M-2031
18 HP VRF ODU M-2030
Supplying, installation, testing and commissioning of Wall Mounted Type split unit Metallic body BMS Compatible VRF Indoor air conditioning units with direct driven fan, Evaporator coil, high efficient filter, inbuilt microprocessor thermostat, electronic expansion valve, provision of fresh air duct connection, necessarysupports & vibration isolators, R410A refrigerant charging, oil charging, power cabling, control wiring and drain connection, etc. The capacities are as mentioned below:- (Approved Makes : Daikin,Hitachi,Carrier,LG,Toshibha, Mitshubishi)
1.6 TR - M-2044 for UPS Room
Supplying, installation, testing and commissioning of Ceiling Suspended 3' X 3' Cassette Type Metallic body BMS Compatible VRF Indoor air conditioning units with direct driven fan, Evaporator coil, high efficient filter, inbuilt microprocessor thermostat, electronic expansion valve, provision of fresh air duct connection, drain pumps for casette, necessary ceiling supports & vibration isolators, R410A refrigerant charging,oil charging, power cabling from nearest socket, control wiring and drain connection, Drain pump,etc. The capacities are as mentioned below:- (Approved Makes : Daikin,Hitachi,Carrier,Toshibha, Mitshubishi)
Supplying, installation, testing and commissioning of Ceiling Suspended 2' X 2' compact Cassette Type Metallic body BMS Compatible VRF Indoor air conditioning units with direct driven fan, Evaporator coil, high efficient filter, inbuilt microprocessor thermostat, electronic expansion valve, provision of fresh air duct connection, drain pumps for casette, necessary ceiling supports & vibration isolators, R410A refrigerant charging, Refnet joints (Refrigerant branch kit) for both liquid and gas line branch kits, oil charging, power cabling from nearest socket, control wiring and drain connection, Drain pump etc. The capacities are as mentioned below:- (Approved Makes : Daikin,Hitachi,Carrier,Toshibha, Mitshubishi)
Supplying, installation, testing and commissioning of Ceiling Suspended Duct Type Metallic body BMS Compatible VRF Indoor air conditioning units with direct driven fan, Evaporator coil, high efficient filter, inbuilt microprocessor thermostat, electronic expansion valve, remote, provision of fresh air duct connection, drain pumps for casette, necessary ceiling supports & vibration isolators, R410A refrigerant charging,oil charging, power cabling from nearest socket, control wiring and drain connection, etc. The below capacity units are OEM units and the capacity are as mentioned below:- (Approved Makes : Daikin,Hitachi,Carrier,Toshibha, Mitshubishi)
4.5 TR - ESP 20mm with drain pump
6.4 TR - ESP 24mm
8.0 TR - ESP 24mm
Supply, installation, testing, and commissioning of Imported fittings Refnet Y-joints, distributor and headers for all Indoor units as per layout drawings.
Supply, installation, testing and commissioning of wired Remote controllers for operation of indoor units ( Ductable split units)
Supply, installation, testing, and commissioning of BMS interface VRF outdoor units bacnet for thrid party system integration, software and licence key,communication cables, basic functions like ON/OFF, mode settings, temperature setting, fan speed setting, louver setting, timer, scheduling, holiday mode setting, error code, alarm, emergency trip, sensors etc.
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable size cable tray/adjustable ring type hanger supports, jointing/brazing including accessories, insulated with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines & cladded with 26G aluminium sheet or FRP cloth with paint finish for exposed area ref.copper pipes. all accessories as per specifications etc. as required
For individual Piping 50 / 100 mm wide Aluminium Tape shall be used at joints of Piping with Bands for identification.
42.0 mm O.D. (insulation : 19 mm)
34.9 mm O.D. (insulation : 19 mm)
28.6 mm O.D. (insulation : 19 mm)
25.4 mm O.D. (insulation : 19 mm)
22.2 mm O.D. (insulation : 13 mm)
19.1 mm O.D. (insulation : 13 mm)
15.9 mm O.D. (insulation : 13 mm)
12.7 mm O.D. (insulation : 13 mm)
9.5 mm O.D. (insulation : 13 mm)
6.4 mm O.D. (insulation : 13 mm)
Supply,installation,testing and commissioning of UPVC drain piping complete with fittings, supports as per specifications and duly insulated with 9 mm thick closed cell elastomeric nitrile rubber or XLPE cladded with 26G aluminium sheet.
Supplying, installing, testing and commissioning of Shielded control cum transmission wiring of 2 or 3 core x 1.5 sqmm copper FRLSH, XLPE insulated cable in suitable GI conduits accessories between indoor and outdoor units. Necessary securing of conduit shall be made by contractor. After completion of work wall and floor shall be repaired and brought to its original finish. The rate will also include cost of laying of GI conduit between indoor and outdoor units.(Based on the OEM Recommendations)
2C/3C x 1.5 Sq mm (Unarmoured)
Providing additional R410A gas charging for the ODU units and ref copper pipes
Supply and Installation of Hot dipped galvanized / Powder coated type perforated type Cable trays of following sizes, suspended from ceiling or fixed vertically on wall / column as per including necessary supports like anchor bolts, etc., and accessories like Elbows, Bends, Tee, required support / suspenders, hardware etc. as per site requirements. All the supporting structure & hardware including nuts & bolts and shall be of galvanized iron as approved. Height of cable tray will be 50mm and all the elbows, Bends, Reducers, Tees should be factory made. 'Ladder Tray is 2mm Thickness and Perforated Tray is 1.6mm Thickness
100mm wide 50mm height -Perforated acble tray
150mm wide 50mm height -Perforated acble tray
SITC Inverter DX Ceiling Suspended Cassette Type with eco friendly refrigerant units of following capacities. The Indoor unit shall comprise of Blowers, Cooling coil, Filter and Expansion device and drain pan,drain pumps and eco friendly refrigerant etc. The Outdoor unit shall comprise of Inverter Compressor, Wireless remote controller for Indoor units, Air cooled condenser & Condenser fans. Rate inclusive of 5kva voltage stabilizer, refrigerant charging, power cable-(7.5 RMT) from the panel/isolator/power socket point to indoor unit including plug top, supports for indoor units and outdoor units etc.The rate shall be inclusive of Insulated drain pipe and Ref.copper pipes
2.0 TR for BMS room
Supply, Installation, Testing and Commissioning of Real Timer for the BMS room indoor cassette units - 12 hrs operation
Supply, installation, testing and commissioning of condensate drain pump for 6.4 and 8.0 Ton Ductable split units the vendor should include the necessary mounting arrangement for the pumps.
2100 CFM with 25 mm static Pressure - Toilet Exhaust air fan (IE3 motor)
4250 CFM with 25 mm static Pressure - Toilet Exhaust air fan (IE3 motor)
3250 CFM with 25 mm static Pressure - Toilet Exhaust air fan (IE3 motor)
3000 CFM with 25 mm static Pressure - Elec room Ex.fan (IE3 motor)
7000 CFM with 3.7KW 25 mm static Pressure - Lit well Pressurization fan
10000 CFM with 5.5KW 25 mm static Pressure - staircase Pressurization fan
Supply, installation, testing and commissioning of propeller type direct drive fan, heavy duty wall mounted type complete with gravity louvers, motors, mounting brackets,, 5A plug top and required cables from nearby power socket, 600x600x20mm thick marine plywood with hole to suit impeller dia, mounting supports and other standard accessories as per specifications and suitable for operation 230 +/- 10%V, 50Hz, 1 Phase AC supply. (Make : Airflow / Maico / Greenheck)
Air flow rate : 150 CFM For security cabin
Air flow rate : 450 CFM For Substation
Supply, installation, testing and commissioning of Ventilation fan circular/ cabinet type units. The unit shall be 0.6mm GIS construction, direct / belt driven centrifugal fan, High efficiency motor with IP21 protection, spring vibration isolator for fan and motor, Fire retardant canvass connections, with acoustic enclosure for fan & noise level not exceed 65 dBA at 1.5m distance, internal power and control wiring, GI base frame complete as per specifications as required. Fan motor shall be suitable for 230V, 1 phase, 50Hz AC supply. Rate shall be inclusive of Suitable power cable from isolator to equipments. (Make : AirFlow / Maico / Greenheck)
Air Qty: 650 CFM, ESP: 10mmWC for Toilet ventilation
Air Qty: 420 CFM, ESP: 10mmWC for Toilet ventilation
Air Qty: 850 CFM, ESP: 10mmWC Toilet ,GF kitchen & Terrace Eec room ventilation
Air Qty: 1500 CFM, ESP: 10mmWC for Fire pump room Ventilation
Supply, installation, testing and balancing of Air Distribution System consists of factory fabricated sheet metal ducting complete with supports (anchor fasteners and tie-rods, cradles, angle iron supports, GI bolts and nuts, 4mm thick self-adhesive neoprene rubber gasket, stiffeners, zinc chromate painted angle iron flanges, chipping and plastering of openings made for duct supports etc., complete as per specification. The rates quoted shall include turning vanes, straightening vanes, splitters, inspection doors probe, inlets with test openings enclosures complete with locking caps, chain, gaskets, etc.
1.2 mm thick GSS ducting (18G) – factory fabricated
1.0 mm thick GSS ducting (20G) – factory fabricated
0.8mm thick GSS ducting (22G) – factory fabricated
0.63mm thick GSS ducting (24G) – factory fabricated
Supply, Installation, Testing & Commissioning of air distribution system consists of factory fabricated GI sheet Flat Oval (elliptical) duct with pre insulated 13 mm thickness nitrile rubber FM approval factory made fittings like bends, tees, wire hanging support with crimp arrangement supports, spacing and fixing as per SMACNA standards. The rate shall be inclusive of powder coating (Mat finish) for the ducts as per the approved colour shade by Client / Architect.
1.0 mm thick GSS ducting (20G) – factory fabricated for GF Cafe
0.8mm thick GSS ducting (22G) – factory fabricated for GF Café
0.63mm thick GSS ducting (24G) – factory fabricated for GF Café
Supply and installing of Acoustic insulation, Material shall be FM approved Nitrile Rubber foam. The material should be fibre free. The density of the same shall be within 140-180 Kg/m3.The material should have a thermal conductivity Not exceeding 0.038 W/mK. The maximum surface temperature the material should withstand is 105º C and minimum temperature should be -20ºC. The Thickness of the material shall be 15mm. The material should conform to Class 1 rating for surface spread of Flame as per BS 476 Part 7.As per specification.
Supply and installation Thermal insulation on ducts with Class 'O' Closed Cell Elastomeric 9mm thick Nitrile Rubber/XLPE with density of 40 - 60 kg/cum as per the thickness mentioned below, with fire retardant adhesive and joints sealed with 3mm thick, 50mm wide nitrile rubber self adhesive tape in accordance with the approved shop drawings and technical specifications. Quoted price shall be inclusive of adhesive, tapes, etc.
Supply and fixing of Under deck insulation with make it as XLPE insulation - 25 mm thick with density of 40 - 60 kg/cum as per the thickness mentioned fixed to the soffit with the help of plastic expansion fasteners. The plastic expansion fasteners is coupled with plastic wheel to support Polyurethane slabs. The fasteners are fixed at an interval of 500 C/C
Supply and installation of GI volume control damper low leakage( handle type ) made out of 1.6mm thick galvanised sheet steel frame and opposed blades of 1.6mm galvanised steel with suitable links, handles, levers and quadrants for manual control of volume of air flow and for proper balancing of air distribution system.as per specification
Rectangular
Supply, installation, testing and commissioning of fire-retardant canvas, with GI matching flanges, with a provision of operable zip. The entire assembly shall be fabricated at factory.
Supply, fixing, testing and balancing of Aluminium powder coated Fresh air and exhaust arrangement with louvers, volume control damper, MS weld mesh bird screen / mounting frame - 100mm louver spacing and 45 deg angle suitable for protection against splashing rain water fixed within a right aluminium frame as per specification.
Supply, installation testing & balancing of Higher grade Aluminium Extruded powder coated grilles with necessary flanges for Supply & Return air. As per specification
Supply, installation testing & balancing of Higher grade Aluminium Extruded powder coated grilles with necessary flanges for Exhaust air. As per specification
Supply, installation testing & balancing of Higher grade Aluminium Extruded powder coated Door Transfer Grille with necessary flanges for Fresh air. As per specification
Supply, installation testing & balancing of collar damper shall be constructed out of extruded aluminium alloy with multiple blade of oppose blade type. The damper to be powder coated with mat finish black colour. The damper shall be used for the Supply air diffuser & grilles as per the drawings & specifications.
Design, Manufacture, Supply, Installation, Testing, and balancing of aluminium powder coated ex.disc valve dia 150mm
Providing the third party agency for testing and air balancing of HVAC system completely as per NEBB guidelines. The agency's technical credentials shall be submitted to the Client / Consultant and work can be commenced after getting approval from the Client / Consultant.
Supply, installation testing & commissioning of Higher grade Extruded Aluminium powder coated Supply Air Diffusers shall be of removable core type (without collar damper) With Outer size: 595x595mm.& 375 x 375mm neck size
Supply, installation testing & commissioning of Higher grade Extruded Aluminium powder coated Return Air Diffusers shall be of removable core type (without collar damper) With Outer size: 595x595mm.
Supply, installation and testing of round flexible duct inner core should be made of triple lamination of Aluminium Foil, Polyester & Metalized polyester film permanently bonded to a coated spring steel wire helix. Fiberglass insulation shall be of 25mm thick with minimum density of 16 kg/m³. The outer insulation jacket vapor barrier shall be made of fiber glass reinforced metalized polyester film laminated with aluminium foil as per the technical specifications. The rate shall be inclusive of hose clamps, supports,bolt,nut etc. AS per specification.(1.2 Mtr)
150mm Dia
100mm Dia
Supply, installation testing & commissioning of Butterfly damper should constructed with Not less than 0.8mm thick galvanized steel sheet, with single flap, necessary stopper, flanges, grooves 150-mm length, neoprene gasket at the edge of blade to reduce leakage and with required hardware and accessories as per specification. Include locking device to hold single-blade dampers in a fixed position without vibration & engraved marking on position of damper, as per specifications.
150mm Dia
100mm Dia
Supply, installation testing & balancing of Higher grade Aluminium Extruded powder coated 25mm 3 slot diffusers with necessary flanges for Supply & Return air. As per specification
FIRE PROTECTION SYSTEM & SIGNAGES
Supply, installation, testing and commissioning of Diesel Engine Driven Main Fire Pump suitable for automatic operation and consisting of following and complete in all respects as required. a. End suction, top discharge centrifugal pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg. / sq. cm at highest and farthest outlet at specified flow of 2280 LPM at 70m head conforming to IS 1520. b. 68 BHP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant BS & IS standard complete. Auto starting mechanism, 12 volts / 24 volts electric starting equipment like self motor, dyanamo, solenoid switches etc. c. 110 litres capacity diesel tank mounted over stand fabricated using 25mm x 25mm x 6mm size MS angle, providing with level indicator, inlet port, outlet port, drain port and diesel return line port and fuel pre-filter, after filter etc. (Make: Kirloskar / Equivalent).
d. Exhaust system having flexible metallic mufler, 100mm dia MS heavy pipe extended upto 1m, outside pump house duly insulated with 50mm thick glass wool with 1mm thick aluminium sheet cladding, residential silencer with necessary MS support arrangements from wall or ceiling as per site condition. e. Dash board consisting the instruments like temperature gauge, galvano type DC Ammeter, lubricant oil pressure gauge, ignition switch, emergency stop and all other protection equipment as per specification, stop seleneid for auto stop in the event of fault with audio indications, painted with post office red colour etc., as required. f. 12 V / 24 V storage battery, maintenance free tape, 180 AH rating, MS fabricated common base plate, coupling guard, foundation bolts etc., as required. g. Positioning the diesel engine driven fire pump over cement concrete foundation using suitable size anti-vibration mounting arrangement. All works carried out as per standard methods and as instructed by the manufacturer and as directed by the TIDEL Officers. (Make: Kirloskar / Equivalent)
Supply, erection, testing and commissioning of Fire Fighting Application Horizontal Centrifugal Type Pump Rated for 2280 LPM at 70 metres head with Electrical Motor of 60 HP of 415 volt 3 phase connection complete with base plate and accessories. (Make: Kirloskar or Equivalent). The rate inclusive of necessary vibration, bad mounting etc., as per standard method as directed by the Departmental Officers.
Supply, erection, testing and commissioning of 180 LPM, 70 metres Head Pressurization Pump with 10HP electrical motor of Kirloskar make with suitable base frame including necessary vibration bad mounting etc., including conveying, fixing and incidental charges, etc., complete as per standard specification and as directed by the Departmental Officers.
Supply, erection, testing and commissioning of fire fighting application monoblock motor pumpset of 450 LPM at 20 metres head to develop 2.0 kg/sq.cm at the heightest and farthest hydrant point to make 10m water jet at the time of fire fighting emergency cicumstances, coupled with 3.75KW / 5HP rated three phase 415 volts, 50 Hz, 2880 rpm electrical motor, the pump with cast ron body, bronze impeller, rope gland packaging, suction size of 80 mm dia. delivery size of 65 mm dia, including the cost of foundaton concrete anti vibration mounting, rain safety hood and etc. complete as directed by the Departmental Officers.
Supplying and fixing air vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. (Fabricated )
Supply, erection, testing, and commissioning of cast iron body and bronze internal PN 1.6 non-rising spindle sluice valve of sizes at required places to control the flow of water including necessary MS flange of table ‘E’, gaskets, bolts & nuts including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary, etc., complete as per standard specification and as directed by the TIDEL Officers. Make: NORMEX / KARTAR /EQUIVALENT.
Supply, installation, testing and commissioning of Cast Iron Butterfly isolation valve (PN:16) as per specification with necessary flanges, GI nut, bolts & washers, painting, etc. Complete as per the technical specification.
150 NB -Gear operated
100 NB -Lever operated
50 NB.-Lever operated
Supply, erection, testing and commissioning of Cast iron body and Gun metal or stainless steel internal Non-return valve of following sizes to control one way flow of water to be installed pump room at delivery line and near overhead tank at terrace level near to jockey pump and motor including necessary MS flange of table ‘E’, gaskets, bolts & nuts, etc. as per IS 5312 including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary, etc., complete as per standard specification and as directed by the TIDEL Officers.
Supply, Installation and Testing of 50NB ball Valve with sight glass and union. Valve shall be made of bronze & shall be single handle ball valve.. Complete as per the technical specification ( For sprinkler risers)
Supplying,installation,testing and commissioning of Brass ball valve having Flanged/screwed with unions ends as per specification with factory finish necessary flanges, Hot Dip GI nut, bolts & washers, painting, etc. Complete as per the technical specification.
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.
Supply, erection, testing and commissioning of following MS ‘C’ Class Heavy Duty Pipe as per IS 1239 to withstand a developing pressure of 10 kg. / sq.cm including necessary fittings like MS flange of table ‘E’, elbows, reducers, gaskets, bolt, nuts with washers & joints as per standard method of arc welding, including one coat metal primer and two coat Post Office Red painting including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary, etc., complete as per standard specification and as directed by the TIDEL Officers. Make: JINDAL / EQUIVALENT.
Note: a) Hangers should not be welded or fastened directly to the pipework, b) the thickness of all parts of pipe supports should not be less than 3 mm, c) pipes should be supported from non-combustible building elements. d) Pipework in corrosive areas should be of either stainless steel or suitably protected against corrosion, e) the pipe support shall be adequately designed to withstand five times the weight of water filled pipes plus 114 kg, f) hanger support shall be provided for pipe sizes upto 50mm dia and MS 'C' Channel support shall be provided for all pipes exceeding 50mm dia, g) The distance between the pipe supports shall not be more than i) 4.5m for pipe sizes upto 65mm dia, ii) 6m for pipe sizes greater than 65mm dia upto 100mm dia iii) 6.5m for pipe sizes greater than 100mm dia, miscellaneous consumables and Painting the above ground pipes works with one coat of metal primer and two coats of fire red enamel paint of shade No. 536 of IS 5 : 2007. The vendor shall also consider the price for chasing / chipping walls, making bore holes in walls / floor and making them good with filler material and finished in cement mortar etc.
200NB - 6.35 mm thick - Class C
150 NB - 5.4 mm Thick - Class C
100 NB - 5.4 mm Thick - Class C
80 NB - Class C
65 NB - Class C
50 NB - Class C
40 NB - Class C
32 NB - Class C
25 NB - Class C
Supply and fixing of Fire fighting application oblique type stainless steel Hydrant Valve of size 63mm dia with oblique type instantaneous coupling with rotating wheel to open and close the valve including MS flange of table “E”, bolts & nuts with washer as per IS 5290 at ring main around the building and wet riser inside the building including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc complete as per standard specification and as directed by the TIDEL Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD /EQUIVALENT.
Supply, and fixing in position of Fire Fighting Application Hose of 63mm dia of 15 metres length binded by copper wire with 63mm dia stainless steel male and female instantaneous fire fighting special coupling as per IS 901 as directed by the TIDEL Officers. Near every hydrant points including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc complete as per standard specification and as directed by the TIDEL Officers. Make: OMEX / KARTAR/ LIFE GUARD / SAFE GUARD /EQUIVALENT.
Supply, and fixing in position of Fire Fighting Application 63mm dia stainless steel short length Branch Pipe with hexagonal type spray nozzle of 15mm (or) 20mm jet bore. Near every hydrant points including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary, etc., complete as per standard specification and as directed by the TIDEL Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT.
Supply of Fire Fighting Application MS Hose Box to keep two number of hoses and 1 No. of branch pipe with nozzle having proper glass window type double door with universe open key, painted inside white and outside Post Office Red. Near every hydrant point including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary, etc., complete as per standard specification and as directed by the TIDEL Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT.
Supply, installation of Fire Fighting Application 180 degree swinging type, hose reel drum with 20mm dia braided thermoplastic hose of 30 metres long, so as to extend to necessary distance by self rolling spindle wheel including necessary 20mm dia ball valve and open and close spray nozzle, warm clip, etc., as per the standard pattern of any reputed make at every floor nearer to hydrant valve, including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary., etc., complete as per standard specification and as directed by the TIDEL Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT.
Supply, erection, testing and commissioning of Fire Fighting 4 Way Fire Brigade Inlet with necessary gun metal 63mm dia non return spring shutter arrangements, so that to control one way flow at the time of emergency water supply by fire and rescue service fire engine entry including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary, etc., complete as per standard specification and as directed by the TIDEL Officers. Make: KIARTAR / OMEX /EQUIVALENT.
Wrapping and coating anti-corrosive treatment for the following under ground MS pipe having one coat of anticorrosive metal primer, one layer of asphalt tar tape wound over the MS Pipe as per standard methods as per standard specifications and as directed by the Departmental Officers Make : IWL- Pypkote / Rustech- Coatek
Supply, erection, testing and commissioning of Air Release Valve of 20mm dia, so as to release airlock in 100mm dia MS pipe at top most wet riser, including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary, etc., complete as per standard specification and as directed by the TIDEL Officers. Make: KARTAR /EQUIVALENT.
Test Array Manifold Arrangement for pumpset with pressure gauge (1 No.), pressure switch (3 No.) as per specification
Supply, erection, testing and commissioning of Pressure Gauge with 0 to 14 kg. range of reputed make with necessary valve, milling thread MS coupling fixed at delivery pipe line in pump house & Every floor sprinkler tap off to read the developing pressure including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary, etc., complete as per standard specification and as directed by the TIDEL Officers. Make: H-GURU / ISI MAKE /EQUIVALENT.
Supply and fixing nominal bore quartized bulb type sprinkler bulb 68 Deg C fast response K-80 pendent type including GI collar for each sprinkler bulb, mounted in MS pipe line using suitable size MS threaded coupling, thread, shellac etc., as per standard methods and including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.
Supply and fixing nominal bore quartized bulb type sprinkler bulb 68 Deg C fast response K-80 upright type including GI collar for each sprinkler bulb, mounted in MS pipe line using suitable size MS threaded coupling, thread, shellac etc., as per standard methods and including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.
Supply, Installation, Commissioning and Testing of suitable size dummy plug for future upright sprinkler head.
Supply, erection, testing and commissioning of UL/FM approved Metallic stainless steel (SS 316) braided Flexible drop pipes of 1500mm length, 25mm Dia with cross bar assembly support suitable for grid ceiling, reducing fitting, special shoulder Nipple, reducing nipple, T bar bracket, bracket clip assembly as per drawing.
Supplying and installing of approved type Rosette Plates (Recessed Type in Two Pieces) for sprinklers below false ceiling area. The Rosette shall be fabricated by MS plate of 2mm thick and the finish shall be powder coated and colour, as directed by the Client/Architect/Consultant
Supplying & installing of FM approved make vane type 150NB flow switches (flow sensors) suitable to be fixed directly on line of the following diameters, with 1 NO & 1 NC potential free contacts (suitable provision for IBMS system)as per specification
Supply and installation of FM approved 150NB alarm check valve with full valve trim. The alarm check valve shall be equipped with a removable cover assembly. The alarm valve shall be listed for vertical position. T shall be equipped with gauge connections on the system side and supply side of the valve clapper. The alarm valve trim piping shall be externally galvanised. Maximum water working pressure to 250 PSI. This shall be inclusive of hydraulic powered water motor alarm by way of integral valve alarm line trim piping. Water motor gong shall be connected to a water pressure retarding chamber to limit the propensity of unnecessary alarms. Water motor alarm shall be equipped with a rear closure plate to limit the access of foreign materials of accumulation of debris as per specification
Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc, complete as per standard specification and as directed by the TIDEL Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT
Supply and fixing of DCP (Dry Chemical Powder ) Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Make: Safex/ Minimax / Ceasefire
Supply and fixing of Carbon-di-Oxide Gas Type 4.5 kg. capacity Fire Extinguisher as per New IS15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc., complete as per standard specification and as directed by the TIDEL Officers. Make: EXCELLENT /SAFETY FIRST / EQUIVALENT
Supply and kept in position of Trolley Mounted Type 22.5 kg. Carbon-di-Oxide Fire Extinguisher as per IS15683, complete with control valve, gun metal cap, pressure gauge, operation sticker, discharge hose, mounting trolley with moving wheel, safety clip, etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: Safex/ Minimax / Ceasefire
Supply and fixing of Aqueous film forming foam 9lts. capacity Fire Extinguisher as per New IS15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc., complete as per standard specification and as directed by the Departmental Officers. Make: Safex/ Minimax / Ceasefire
Supply and kept in position of 9 litres capacity Fire Buckets of 4 Nos. with Bucket Stand as per standard specifications and as directed by the TIDEL Officers
FIRE FIGHTING PANEL
INCOMER
(a) 2Nos of 250 Amps,4P,36KA, MCCB and MFM Meter with CT (b)Set of 3 Phase indicating lamp. (c) Set of AL bus bar Amps. (d) Electrical lnterlocks
OUTGOING.
NOTE:- Control & interlock arrangement in between Jockey Pump, Main pumps, & Diesel engine pump shall be enclosed in the panel. The panel shall also be provided with an industrial hooter for alarm and necessary suitable relays shall be provided and NO + NC contacts shall be provided for IBMS communications
Supply and laying of 3.5 Core 240 Sq.mm LT XLPE Alu.Arm cable Aluminium Armoured Cable - Electrical panel to main panel
Supply and Laying of 3.5Core 70 Sq.mm PVC/XLPE Aluminium armoured cable - Fire pumps panel to Main pumps
12 Core 2.5 Sq.mm PVC Copper Armoured Cable - Diesel Engine Auto start panel to diesel engine
4 Core 16 Sq.mm PVC Copper Armoured Cable - Fire pumps panel to jockey pumps
2 Core 1.5 Sq.mm PVC Copper Armoured Cable - Pressure switch cable
Design, supply and laying of 25 x 6 mm copper flat for panel earthing
Design, supply and laying of 8 gauge bare copper wires for Gland earthing, loop earthing in the existing surface/recessed steel conduit, pump earths and other equipment body earthing as required. (For Jockey pump earthing)
Design, supply and laying of 25x3 Copper Flat pump body earthing for electric driven pumps , diesel engine pumps and run along with cable tray
Supply and installation of 2m x 1m Rubber Mat confirming to IS (5 Nos)
Supply and erection of following sizes GI ladder type cable rack system made out of 14G GI sheet folded to required shape with adequate number of supports. The rate shall be inclusive of suitable hanging support
150mm x 50mm x 2.0mm - Fire pump room jockey pumps
300mm x 50mm x 2.0mm - Fire pump room Main pumps & Diesel pump
SIGNAGES
Providing and installing in position the following type of sign boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC non-reflective self adhesive vinyle painted foam board, complete with mirror fasteners. Make : Prolite / Ravel
Signage with printed "IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE" of 1.5cm height letters in red with white back ground.The size of the board shall be 25cm x 30 cm and shall be fixed at the height of 2 mts. from finished floor near Manual call points. Make : Prolite / Ravel
Floor indentification signage ( ie, GROUND FLOOR …etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5 cm with contrasting colour from back ground.Size shall be 15cm x 60cm.Make : Prolite / Ravel
Providing and fixing in position the signages " FIRE ORDER" it should contain the following matter on 3mm thick "Opaque" PVC foam board of computerised cut, PVC non-reflective self adhesive vinyle painted foam board of 3' x 4'. ALERT THE SECURITY AT SECURITY ROOM BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATION . EVACUATE THE OCCUPANTS BY USING THE FIRE EXITS & EMERGENCY EXITS ONLY. ASSEMBLE AT VARIOUS ASSEMBLY POINTS. IF POSSIBLE TRY TO EXTINGUISH THE FIRE BY USING THE NEAREST/SUITABLE PORTABLE EXTINGUISHER OR WATER FROM NEAREST WET RISER BE CALM, DO NOT GIVE ANY ROOM FOR PANIC, WALK, DO NOT RUN IF YOU ENCOUNTER SERIOUS DIFFICULTY IN EVACUATION, STAY IN YOUR PLAN AND TRY TO ATTRACT ATTENTION OF RESCUE TEAM . Make : Prolite / Ravel
Providing and installing in position the following type of sign boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC non-reflective self adhesive vinyle painted foam board, complete with mirror fasteners ACTION BY SECURITY/RECEPTION UPON RECEIPT OF INFORMATION THROUGH FIRE ALARM OR FIRE DETECTORS OR BY USING PUBLIC ADDRESS SYSTEM. A) ALERT THE OCCUPANTS BY USING PUBLIC ADDRESS SYSTEM. B) INFORM FIRE CONTROL THROUGH ANY ONE OF THE FOLLOWING PHONE NUMBERS: C) IN CASE OF THE CASUALTIES, CALL AMBULANCE BY DIALLING NUMBER…….. FIRE FIGHTING AGNECY ------------------------------- PHONE : ----------------------- FAX : ----------------------------
Fire and emergency signage Boards( Fire escape directions, First aid charts, First aid box indications, safe material handling procedures, Fire assembly area indications etc,)
Providing and installing of Fire Evacuation Plan with route in rectangular Acrylic sheet with ss bolt of size 600 x 450mm & 2 to 3mm thick
LIFT ( 3 x 16 Passengers + 1 x 2000 Kgs Goods Lift)
Design, Engineering, Supply, Fabrication, Erection, Testing, commissioning and handing over of 20 persons capacity passenger lift as per the following specifications.(Gearless lift without machine room)
1.Location: TIDEL Neo, Karur
2.No of lift: 1 No. (MRL-Gearless)
3.Type of lift: passenger Lift
4.Capacity of lift: 16 / 1088Kgs
5.Speed: 1.25 m / sec
6.Type of drive: V3F drive with enhanced ride comfort and near zero level functions
7.No of floors: GF+4 Floor
8.Total travel: 20.4 mts
9.Leveling accuracy: high level accuracy with smooth and jerk free stopping
10. Construction of CAR: No. 4 hardened sheet high quality stainless steel car and hand rail granite flooring and Perspex false ceiling.
11. Position of machine: Not required for MRL lift
12. No of landing service: One in the front side- 1 no.
13. No. of car entrance: one in the front side only
14. Car entrance door: power operated automatic V3F drive center opening sliding SS door
15. Landing entrance door: power operated V3F drive center opening sliding SS door with provision for emergency exit key at all landings.
16.Lift well size :2500 mm (wide) X 2300 mm (depth). The well final size as per final GFC Drawing
17.Lift pit depth:1800 mm
18. Car inner size: As per IS 14665 (part 1) Year of 2000, overhead 4200mm and Total weight of person – 884 Kg
19. Car clear opening: 1000mm (width) x 2000mm (Height) as per IS
20. Power supply: 400 / 440 v three phase 50 Hz AC supply for power and 230 V 50 Hz single phase power supply for light.
21.Control: micro computer (micro processor):based simplex collective control with / without attendant
22. Car fittings: LED fitting with 1 no 300 mm sweep cabin fan.
23. Lift well: RCC construction with brick masonry to be constructed by the civil wing.
24. Induction: UP / DOWN digital direction and position indicator for all landings and inside the car.
25.Emergency alarm bell: battery operated bell to be provided with automatic charging device
26.Emergency light: battery operated light to be provided with automatic charging device
27.Fire mans switch: to be provided at the GF
28. Minor builder works: to be provided by the lift contractor.
29. Scaffoldings: to be provided by the lift contractor.
30. Sill angles and facia plates: SS to be provided by the lift contractor.
31. Steel for lift machinery: to be provided by the lift contractor.
32. Servicing and maintenance: free comprehensive servicing and maintenance for one year Guarantee period to be provided by the lift contractor.
33. Automatic rescue device: to facilitate the landing of the nearest floor at the time of power failure this shall consist of suitable battery system with charger inverter under voltage protection system etc. complete with all accessories.
34. Provision for intercom with phone: to be provided by the lift contractor.
35.Lift license: preparation of drawings payment of charges to CEIG and insurance policy and obtaining CEIG approval for the lift as per lift act should be done by the lift contractor
36. Floor position announcer: to be provided by the lift contractor.
37.Special features
a) Infra red door sensor with full height screen
b) Full width half height rear panel mirror
c)Tubular SS hand rail in car
d) Stainless steel signal features
e) Vandal proof SS button with SS cover
f) SS door frames for landing doors
g) V3F door operator
h) Call register signal
i) Stainless steel facia plates for car operating panel and landing fixtures
j) Steel ladder for lift machine room - Not applicable for MRL lift
k) On / off switch for fan and light
l) Over load warning indicator with audio announcer
m)Voltage stabilizer for control circuits
n)Braille button and mirror
o) Disabled friendly
38.Over speed governor phase failure and phase reversal relay alarm bell T guide brackets for car and counter weight rubber padding under the winding unit motor of adequate capacity signal reduction worm gear electromagnetic brake with compression springs car safety gears buffers electro mechanical locks emergency key side supporting angles motor over load protection devices final limit switch main suspension ropes counter weight lifting joist for mounting the machineries
39. Guarantee: guarantee at least for one year for the material and workman ship of equipments should be offered by the lift contractor.
40. Site testing in accordance with IS 14665 should be carried out at the time of handing over to the user department
41. All the features as per differentlyabled persons act should be provided.
42. 2 hours Fire Retradent landing doors.
43. Supply operation and maintenance manual and necessary tools for operation and a set of
44. Spare parts required for one year.
45. Lift car panel - 1 No
45. LIFT all internal wiring will be done by Lift manufacturer.
GOODS LIFT (2000 Kgs) - (MACHINE ROOM LESS LIFT)
Design, Engineering, Supply, Fabrication, Erection, Testing, commissioning and handing over of Goods Lift (2000 Kgs) as per the following specifications (Machine room less)
1.Location: TIDEL Neo, Karur
2.No of lift: 1 No. (Gearless)
3.Type of lift: Goods Lift
4.Capacity of lift: 2000 Kgs
5.Speed: 1m / sec
6.Type of drive: V3F drive with enhanced ride comfort and near zero level functions
7.No of floors: GF+4 Floor ( 5 Landings)
8.Total travel: 20.4 mts
9.Leveling accuracy: high level accuracy with smooth and jerk free stopping
10. Construction of CAR: SS/ Decorative Laminated Steel Sheet (Dlss)
11. Position of machine: Lift machine room
12. No of landing service: One in the front side- 1 no.
13. No. of car entrance: one in the front side only
14. Car entrance door: power operated automatic V3F drive center opening sliding SS/DLSS door
15. Landing entrance door: power operated V3F drive center opening sliding SS door with provision for emergency exit key at all landings.
16.Lift well :2500 mm (wide) X 3700 mm (depth) as per IS 14665(part1) Year of 2000 to be constructed . The well final size as per final GFC Drawing
17.Lift pit depth:1800 mm
18. Car inner size: As per IS 14665 (part 1) year of 2000
19. Car clear opening: 1200 mm wide x 2000 Height or as per IS 14665 (part 1) year of 2000
20. Power supply: 400 / 440 v three phase 50 Hz AC supply for power and 230 V 50 Hz single phase power supply for light.
21.Control: micro computer (micro processor):based simplex collective control with / without attendant
22. Car fittings: CFL lighting with 1 no 300 mm sweep cabin fan.
23. Lift well: RCC construction with brick masonry to be constructed by the civil wing.
24. Induction: UP / DOWN digital direction and position indicator for all landings and inside the car.
25.Emergency alarm bell: battery operated bell to be provided with automatic charging device
26.Emergency light: battery operated light to be provided with automatic charging device
27.Fire mans switch: to be provided at the GF
28. Minor builder works: to be provided by the lift contractor.
29. Scaffoldings: to be provided by the lift contractor.
30. Sill angles and facia plates: SS to be provided by the lift contractor.
31. Steel for lift machinery: to be provided by the lift contractor.
32. Servicing and maintenance: free comprehensive servicing and maintenance for one year Guarantee period to be provided by the lift contractor.
33. Automatic rescue device: to facilitate the landing of the nearest floor at the time of power failure this shall consist of suitable battery system with charger inverter under voltage protection system etc. complete with all accessories.
34. Provision for intercom with phone: to be provided by the lift contractor.
35.Lift license: preparation of drawings payment of charges to CEIG and insurance policy and obtaining CEIG approval for the lift as per lift act should be done by the lift contractor
36. Floor position announcer: to be provided by the lift contractor.
37.Special features
a) Infra red door sensor with full height screen
b) Full width half height rear panel mirror
c)Tubular SS hand rail in car
d) Stainless steel signal features
e) Vandal proof SS button with SS cover
f) SS door frames for landing doors
g) V3F door operator
h) Call register signal
i) Stainless steel facia plates for car operating panel and landing fixtures
j) Steel ladder for lift machine room
k) On / off switch for fan and light
l) Over load warning indicator with audio announcer
m)Voltage stabilizer for control circuits
n)Braille button and mirror
o) Disabled friendly
38.Over speed governor phase failure and phase reversal relay alarm bell T guide brackets for car and counter weight rubber padding under the winding unit motor of adequate capacity signal reduction worm gear electromagnetic brake with compression springs car safety gears buffers electro mechanical locks emergency key side supporting angles motor over load protection devices final limit switch main suspension ropes counter weight lifting joist for mounting the machineries
39. Guarantee: guarantee at least for one year for the material and workman ship of equipments should be offered by the lift contractor.
40. Site testing in accordance with IS 14665 should be carried out at the time of handing over to the user department
41. All the features as per differentlyabled persons act should be provided.
42. 2 hours Fire Retradent landing doors.
43. Supply operation and maintenance manual and necessary tools for operation and a set of Spare parts required for one year.
44. Lift Car operating panel : 1 No
45. LIFT all internal wiring will be done by Lift manufacturer.
ADDRESSABLE FIRE ALARM SYSTEM
Supplying, installing, testing and commissioning approved make Modbus Interface Gateway for communication with BMS /CCTV/ Other Utilities. Modbus shall support Supports reads of up to 100 registers at a time. Modbus Gateway shall act as an independent node communicating on the peer to peer network and shall not be dependent on the Fire Panel CPU for operation. Modbus over TCP/IP , Meets UL 864, 10th edition requirements, Supports two Modbus masters & monitored 10 CPU nodes . Failure of Fire Panel CPU shall not result in failure of MoDbus Gateway. The Gateway Card shall be UL Listed
Supplying, installing, testing and commissioning approved make Network Repeater Panel with minimum 5" Color Touch Screen display. The NRP shall act as an independent node communicating on the peer to peer network and shall not be dependant on the Fire Panel CPU for operation. Failure of Fire Panel CPU shall not result in failure of NRP operation.UL Listed & FM approved
SMS alarm notification module with unlimited user capability, SMS Paging Facility for transmitting specified alarms to designated personnel.Required Hardware & Software.
Supplying, installing, testing and commissioning approved make Addressable Multi-criteria Photo-Thermal Above False Ceiling Detector with sensitivity range of 0.5 to 4.0% obs/ft.The intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal switches. Detectors having base addressing must provide protective cap. Detectors with soft addressing must provide programming tool. The detector sensitivity (day & night) shall be controlled from the panel to get accustomed to the local environment. Detector with base,powder coated back box and other accessories as required. The detector shall be UL Listed & FM Approved.(TRUE CEILING/ABOVE FALSE CEILING & FALSE FLOOR)
Supplying, installing, testing and commissioning approved make Addressable Multi-criteria Photo-Thermal Above False Ceiling Detector with sensitivity range of 0.5 to 4.0% obs/ft.The intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal switches. Detectors having base addressing must provide protective cap. Detectors with soft addressing must provide programming tool. The detector sensitivity (day & night) shall be controlled from the panel to get accustomed to the local environment.Detector with base and other accessories as required. The detector shall be UL Listed & FM Approved.(for below false ceiling areas) Below False Ceiling
Supplying, installing, testing and commissioning approved make Addressable Thermal Above False Ceiling Detector with sensitivity range of 0.5 to 4.0% obs/ft.The intelligent multi criteria detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. The detector shall have twin bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary decimal switches. Detectors having base addressing must provide protective cap. Detectors with soft addressing must provide programming tool. The detector sensitivity (day & night) shall be controlled from the panel to get accustomed to the local environment. Detector with base and other accessories as required. The detector shall be UL Listed & FM Approved.(for below false ceiling areas) Below False Ceiling
Supply Installation Testing & Commissioning of Response indicator with powder coated back box and other accessories as required for all detectors located above false ceiling / False flooring with all mounting accessories .
Supplying, installing, testing and commissioning approved make Isolator Module for Isolating short / dewired / loose circuits with automatic resetting arrangement.The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. The Isolator module should not consume an address in the SLC loop.Module shall be supplied with mounting plate from OEM for ease of installation & maintenance.UL Listed & FM approved
Supplying, installing, testing and commissioning approved make Addressable Monitor Module for Sprinklers, Panic Bars & other Third Party Inputs. The monitor module shall monitor potential free contacts. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance. The device shall be UL Listed & FM Approved. - To monitor the flow switches, Tenant panel integration,Third Party System Integration etc
Supplying, installing, testing and commissioning approved make Addressable Relay Module for AHU, Access Control, Lifts, Staircase Pressurization, Fire Suppression & other Third Party Outputs. The relay module shall provide contact rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance. The device shall be UL Listed & FM Approved. The hooters shall be made of ABS plastic, and have a DB level of 65dbA and a multi tone facility. shall be fitted in a junction box.
Supplying, installing, testing and commissioning of approved make Fire Alarm LED Hooter cum Strobe (sound output of minimum 85 dB, Light output: 15, 30, or 75 candela ) made Addressable with the help of Intelligent Addressable Signal Module, with separate power supply arrangement complete as required and suitable for wall/ceiling mounting and as per specifications. UL / FM Listed. The rate shall include suitable size of MS Powder Coated (Fire RED) medium duty Junction box medium duty with GI metal glands for IN /OUT
Supply, installation, fixing, testing and commissioning of Hooter Module with Junction box and other accessories as required - To activate the hooters at fire condition
Supplying, installing, testing and commissioning approved make Addressable Manual Call Point ( Dual Action Type). The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. The device shall be UL Listed & FM Approved.
Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers.
Supply and fixing of approved make FRLS PVC conduits on ceiling / wall / floor etc. complete with accessories like, Junction boxes, Collars, Bends, clamps, saddles etc. (for MCP)
25 mm dia.
SITC of PSU for hooters (inclusive of Battery ckt & battery)
PUBLIC ADDRESS SYSTEM
Supply, installation, commissioning of 6W RMS False Ceiling Mount Speakers with inbuilt 100V Line Matching Transformer, wide opening angle, optimized for music & speech applications with mounting clamps as per specifications.Speakers shall be IEC and BS Compliant
Supply, installation, commissioning of 6 W Wall Mounted box Speakers with line matching transformers as specified as per specifications
VOICE ALARM SYSTEM CONTROLLER: Supply, installation, commissioning of Microprocessor based System Controller with builtin 240W Amplifier, EN-54 for connecting min 6 zones,Controller built in 6 Zone min with complete rack mounting accessories, with 6 Zone Call Station and emergency microphone to make announcement for all the floors with built in Stem Type Microphone on call station, integration facility with Fire Alarm System, fire trigger alarm module, message manager, Speech Processor with relays for activating pre-recorded fire alarm messages with the required interface card to connect to the additional call zone stations and required interface units to connect amplifier and routers.it will vary as per client requirement.
Supplying, installing, testing and commissioning of Power Amplifier of 240 W RMS out put in rack, including necessary control wires, jocks etc. complete.
Supplying, installing, testing and commissioning of Power Amplifier of 480 W RMS out put in rack, including necessary control wires, jocks etc. complete.
Supply and laying of 2 core 1.5 sq.mm. Armoured Speaker Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers.
Rack Mounted DVD Player/Mixer Amplifier as per specifications
Supply, Installation, Testing and Commissioning of Min 36U/42U size rack as per following specification, Floor/ Wall Mounting rack with Front Glass door & Rear Plain Door with handle lock, 1 Shelf 400mm and mounting hardware packet of 20, Cable Manager, PDU 6sockets - 2 Nos ,Side panel Number of racks shall be as per the design requirement. vendor to consider required number of racks as per their requirement
IP CCTV SYSTEM
Supply, Installation, Testing and Commissioning of Indoor Dome Camera, Wide Angle IP dome, POE ,1/3" CMOS, Min. 5 MP Resolution, Dual H.264 / H.265 Streaming, 25 fps, fixed lens 2.6/2.8/3/3.6mm, 0.5 lux for colour, Tamper detection, 3D Noise reduction, Auto Gain / Auto White Balance. PoE, Cameras shall have basic analytics features such as motion detection, video tampering, and tripwire. Intrusion, Scene changing, With LATEST ONVIF Compliance , IEEE802.1X Security Protocol is must in all models IP cameras. Camera Shall also have Listing of (UL60960-1,IEC 600068-2-1,EN 55022 Class B , EN 61000-6-1, EN 61000-6-2 ) , STQC certificate.
Supply, Installation, Testing and Commissioning of Outdoor IP Bullet Type Camera ( Periphery walls / Building external walls) IP Bullet Camera, POE, Outdoor Weatherproof, Min 5 MP , 1/3 CMOS, IR Cut lens , IR for 25 meters, POE ,Vandal / Tamper proof, Optical WDR > 100 Db ,Auto Gain / Auto White Balance . IP 66 & Vandal proof enclosure , 3D Noise reduction,Cameras shall have basic analytics features such as motion detection, video tampering, and tripwire. Intrusion, Scene changing, PoE & standard 12VDC/24VAC power input . IEEE802.1X Security Protocol is must in all models IP cameras. Camera Shall also have Listing of (UL60960-1,IEC 600068-2-1,EN 55022 Class B , EN 61000-6-1, EN 61000-6-2 ) .STQC certificate.
Supply, Installation, Testing and Commissioning of Outdoor Application Low Light IP Hi speed Dome type PTZ camera with 4 MP Resolution, mim 32X optical zoom, Low Light ,Day/Night, Wide dynamic range > 100 dB, Dual H.264 streaming, 0.05 lux, vandal resistant, 360° continuous pan, -0° to +90° tilt, 256 preset, IP66 rated with built in heater and blower, Mounted on Wall/Pole as per site requirement (including required accessories), Cameras shall have basic analytics features such as motion detection, video tampering, and tripwire. Intrusion, Scene changing, UL listed as per detailed specifications. IEEE802.1X Security Protocol is must in all models IP cameras. Camera Shall also have Listing of (UL60960-1,IEC 600068-2-1,EN 55022 Class B , EN 61000-6-1, EN 61000-6-2 ). STQC certificate.
Joy Stick to Control PTZ Cameras
Supply, Installation, Testing and Commissioning of 32 channel Network Video recorder with embedded software Up to 8 Mega pixel (3840 x 2160) recording resolution, Simultaneous HDMI, VGA and CVBS output, HDMI and VGA output up to 1920 x 1080P resolution, Gigabit network interfaces, eSATA interface for recording or archiving (3.5" SATA I/II/III HDD*8),include Required hardware storage of 30 Days of 24 x 7 Continuous recording at 4MP 25FPS,Wireless Mouse. It shall have required graphics cards to display the cameras cameras in multiple screens, bandwidth as required (Min. 360 Mbps) or as required more to connect the 32 cameras.Including HDMI cable for monitor and all other accessories required for proper funtioning of the system.This NVR is to be accommodated in rack.
55" LED Video Wall monitor with HDMI capable of 24 x 7 operation, including software, hardware, mounting bracket and fitting and accessories to stream live video to Monitor with 16 / 32 camera display per screen
HDMI Video Wall Controller 3X3, DVI TV Wall Multi-Viewer Processor with Audio 1080P 60Hz 2x2 2x3 2x4 1x3 1x4 1x5 TV Wall 9 Screen Video Wall Stitching Processor TV Splicing Box 180 Degree Rotate with HDMI Cable(2 Mts-5 Nos) and necessary configuration.
REMOTE VIEWING STATION (RVS)
Video Monitoring Station - Shall have the following configurations and features 1) Processor - Intel® Core i7® Processor 2) Memory: 16 GB DDR4 ECC RAM or better. 3) OS - Windows 10 Professional; 4) Networking - 2x 1GbE RJ45 Ports 5) HDD - 1 TB SATA 6) Graphics Card-4 GB or more 7) Supporting Two Monitors If vendor Server requirement is more than what is specified here, then required server configuration to be considered for Costing. Configuration of RVS requirement proposed by OEM.
Supply,Installation,Testing and commissioning of 32' Monitor with HDMI Cables - Control Room with necessary mounting bracket and fitting accessories
5 Meter MS Circular Pole (FROM GROUND LEVEL) - Min. 80mm dia or More as required, 2 coats of reoxide primer and 3 coats of external colour as per Architects recommendation, complete with mouting accessories as required for the pole as well as the cameras, suitable to mount the outdoor cameras to the directions of the consultant.Pole to have adjustable options to mount at different heights - 3,4 & 5 Meters. Foundation including excavation and refilling etc as required with junction box for looping of power cable. Pole type & color to be matched with Lighting pole or as required at site.
2 Meter MS Circular Pole (FROM GROUND LEVEL) - Min. 80mm dia or More as required, 2 coats of reoxide primer and 3 coats of external colour as per Architects recommendation, complete with mouting accessories as required for the pole as well as the cameras, suitable to mount the outdoor cameras to the directions of the consultant.Pole to have adjustable options to mount at different heights - .5, 1, 1.5 & 2 Meters. Foundation including excavation and refilling etc as required with junction box for looping of power cable. Pole type & color to be matched with Lighting pole or as required at site.
Access Control System
SITC of Client Server PC for Access Management : Supply, installation, testing and commissioning of Access Server shall comprise of the following minimum hardware: Xeon Octa Core Intel Series Processor at mim 3 GHz 20M Cache, 8GB or more of RAM, 1 Tb hard drive, Required Graphics Card-4 GB or more. DVD player - Read and write with video card and video recording application with 15 min UPS Redundant power supply unit ,Standard video display adapter Microsoft® Windows latest 64 bit OS with AntiVirus,MS Windows Server Software and operating license; and required MS SQL Server License etc. The workstation shall be supplied with 21" LED Monitor.. If vendor Server PC requirement is more than what is specified here, then required Server PC configuration to be considered for costing.Configuration of Server requirement proposed by OEM.
Access Control Software: Supply, installation, testing and commissioning of Client Version Application Software for Access Control and attendance software for office area :- (Location :IBMS Room). Shall be Capable of Dashboard builder,Graphic pages for each Acs Door/barriers, floor plans, summary pages, and the dashboard. Generating Multiple Reports in Excel format , such as Department wise / Door Wise / Card Wise / Day wise / Weekly, monthly reports etc.
Supply, installation, testing and commissioning of IP Based Door Access controller -Capable of connecting single door / Single lane of barriers with IN and OUT readers.Supply, installation, testing and commissioning of Two Reader Control panel housed in MS Powder Coated Cabinet with Tamper Switch, complete with On-board IP / LAN port, and Built-in Web Server for Remote Log in to every controller.Also the Controller should have spare potential free contact to trip any third part system if required. - one controller shall have attendance software for admin office staffs. The controller shall have necessary inputs and outputs to connect the Door Electromagnetic locks, Buzzer, Fire trip and Magnetic contacts.The enclosure shall also house the necessary Power supply to the respective Electromagnetic locks.
Supply, installation, testing and commissioning of Readers - Smart Access card readers capable of reading cards of multiple technologies (Iclass / Proximity / Mifare). The readers shall be installed on the wall/Metal Surface/Metal Frame/Wooden Frame/Barriers. Necessary accessories to be considered.
Supply, installation, testing and commissioning of Access cards - Smart access card without Logo & Stickering as per requirement.
Supply, installation, testing and commissioning of Magnetic Contact/Door Position sensor_Provide dual-output door position sensor; one output interfaced with ACS controller for door monitoring/control, and the second output interfaced with BMS controller for door status feedback.as per specification and with all accessories complete as required
Supply, installation, testing and commissioning of Push Button/Switch as per specification and with all accessories complete as required
Supply, installation, testing and commissioning of Electromagnetic locks -Single leaf- 600lbs with necessary Z/L brackets and mounting accessories
Supply, installation, testing and commissioning of Emergency release switch
Supply and Laying of FRLS AB Copper Armoured Cable,PVC insulated, shielded PVC Sheathed layed with fittings & G.I Supports at 0.3mtr .
8C x 0.75 Sq.mm
4C x 0.75 Sq.mm
2C x 1.0 Sq.mm
6C x 1.0 sqmm
3C x 2.5 sqmm unarmoured copper conductor cable for Power Supply
Supply and Laying of 25mm dia, Heavy Gauge FRLS PVC Conduit with all necessary accessories.
Supply and Laying of 19mm dia, Heavy Gauge FRLS PVC Conduit with all necessary accessories.
Supply and fixing of GI Raceway trays with Cover - 100mmx50mmx1.6mm thick with all necessary accessories.including excavation,Floor Cutting and refilling etc as required with junction box.
SITC of Power Supply Units for EM Locks & Controllers
Boom Barriers & Flap Barriers
Supply, Installation, Testing and Commissioning of 1 Set Speed Swing barrier(1 Normal lane + 1 Wider lane) in SS Finish, with SS long housing, Servo position Drive with tooth holding break technology, 1800 mm Glass , sensor should be hidden not visible and shall be in specific pattern , detection shall be in algorithm based and with all mounting accessories. Capable of Free Egress in case of Fire Alarm / Emergency Event and Automatic Reset after resuming of Normal signal or Power. Mean Cycle Between Failure shall be minimum 12 Million Shall have Access reader on both sides for Bi-directional Access.
Supply, Installation, Testing and Commissioning of 2 Set Speed Swing barrier(2 Normal lane ) in SS Finish, with SS long housing, Servo position Drive with tooth holding break technology, 1800 mm Glass , sensor should be hidden not visible and shall be in specific pattern , detection shall be in algorithm based and with all mounting accessories. Capable of Free Egress in case of Fire Alarm / Emergency Event and Automatic Reset after resuming of Normal signal or Power. Mean Cycle Between Failure shall be minimum 12 Million Shall have Access reader on both sides for Bi-directional Access.
Automatic boom barrier: Barrier Front Design Round, Barrier Colour Silver/Grey Colour, Electromechanical Drive Mechanism, 6 meters boom arm, Illuminated Boom Arm (Red/Green), Opening Speed : 2.5 to 4 Sec, Reverse on Obstable Detection, Intelligent control mechanism, Automatic Fault Detection, Led Indication on barrier body (Red/Green), Duty Cycle 100 %, IP Rating : IP 54, The system is compatible with BMS integration via BACnet TCP/IP and RS-485 communication protocols,Complete in all respect for 4 Wheeler Entry/Exit. The barrier shall possess integrated photocells with hide-away system that enabling a perfectly integrated with the look ensuring maximum functionality. The Barrier shall be installed with proper foundation plate and Induction loops.The power supply to the barrier shall be 230V AC and to the motor shall be 24VDC, shall have a min torque of 200Nm. Include all required Pushbuttons for Manual operation etc & Sensors. Wired Remote control with Required accessories.
NETWORKING- DATA & VOICE
PASSIVE DATA
Supply, Laying, testing and commissioning of Unshielded Twisted pair CAT6A UTP Cable - Un Armoured (As per EIA /TIA Standards) 23 AWG Cable - Indoor through partly Tray / PVC Conduits- Only UTP Cable to be considered. Include Fluke Testing & Terminations.
Supply installation, testing and commissioning of 1U, 24 Port Fully loaded Jack / patch panel - Cat6A Cable Termination for Data, Voice & ELV.
Supply, installation, testing and commissioning of Cat6A RJ45 I/O Information Outlet with a separator to eliminate cross talk. Color to be confirmed with client before ordering - For IP Data & IP Voice, IP TV outlets. Include Fluke Testing & Terminations. Also inclusive of supply and Fixing of 1Set of 4 Module cover plate with frame only of White Colour shall only be considered under this item, but including with suitable size back box . Meant for Work stations. Suitable for Data & Voice information outlets like RJ 11 , RJ 45 & TV Socket Outlets. Since the mentioned items will be mounted on the table or wall based on site conditions, if mounted on the table, the necessary provisions shall be made by the furniture vendor. i.e. set up will be mounted on the on the table top itself .
Supply, Installation, Testing & Commissioning of Cat6a patch cord (With Moulded boots) - 1.5 Mtr Length.
Supply, Laying, testing and commissioning of 6 Core OM4 Multi Mode optical fiber cable (Corrugated Steel Tape Outdoor Armoured, Loose tube, Gel Filled, 9/125 Micron OS2). Include Fiber Splicing & Fluke Testing.
Supply, Laying, testing and commissioning of 12-fibre 1-U rack mount optical fibre panel, loaded with 6 Duplex LC-MM adapters, 12 MM OM4 pigtail, 1m each, and 12-core Fusion Splice Tray: Consisting of panel. Include Fiber Splicing & Fluke Testing.
6 Port Fully loaded LIU with all required accessories for complete functioning such as adapter plates, pigtails, adapter sleeves etc., for fibre cable connectivity at the network switch end
NETWORK RACKS
Supply, installation, Testing and Commissioning of 6U IT Industry standard Rack with Black Powder Coated, PDU,Secured Lock with Key, with standard trays, Fans, Castors, Front Glazed Door & Rear MS Door.
Supply, installation, Testing and Commissioning of 12U/15U IT Industry standard Rack with Black Powder Coated,PDU, Secured Lock with Key, with standard trays, Fans, Castors, Front Glazed Door & Rear MS Door.
Supply, installation, Testing and Commissioning of 42U (800mm x 1000 mm) Closed Rack with Perforated lockable front and back doors( 2 Nos), Fan at the top of the rack (Min. 90 CFM), AC Main Channels( Min 10 Points of 5.15A Sockets) vertical x 2, AC Distribtion Box, PDUs, Side Panels, Vertical Cable management high density rack at right and left, Horizontal Cable Manager, Cantilever Tray, Earthing Kit, Front Mounting Cable guides x 4, Front Cover at both sides, Adjustable Levellers with castor wheels, Mounting Hardware & all Acessories as required - BMS Room
FRLS PVC CONDUITS
Supply and laying of heavy gauge rigid PVC conduit of 2mm thick with all conduit accessories PVC junction/pull boxes, G.I fish wire, fixing accessories etc, as required complete for earth cables mechanical protection ( Including wall chipping and covering with cement morter by providing chicken wire mesh wherever necessary and also GI Fish Wire. ) Note : For Earthing cables
32 mm dia Conduit
25 mm dia Conduit
Supply, Fixing of Perforated GI cable tray with Cover : complete with supports, all fittings and mounting accessories, etc complete to installation requirements.-
300 mm x 50 mm x 2 mm
PIPES
Supplying, laying, installation, testing and commissioning of Double Wall Corrugated (DWC) pipes complete with all fittings and accessories; Pipes shall be installed in Group Saddles; group saddles is in vendor scope and the same shall be supplied by the vendor - 50mm DWC Pipe for cables with couplers excavation, back filling, etc as per standard, complete with fittings and clamps including cutting and making good etc.
ACTIVE DATA
Layer2 Switches & Components
Supply, Installation, testing and Commissioning of Layer 2 Managed Switch- 24 ports of 10/100/1000 MBPS or more with 4 SFP Ports- Min 1GBPS - 2 Nos SFP Fiber Ports with Modules loaded & Include all required components for multiple switch stacking Kit. Include all Accessories as required as per site specific requirement for complete functioning.. All Accessories shall be of same Make as the OEM.
Supply, Installation, testing and Commissioning of Layer 2 Managed POE Switch- 24 ports of 10/100/1000 MBPS or more with 4 SFP Ports - Min 1GBPS - 2 Nos SFP Fiber Ports with Modules loaded & Include all required components for multiple switch stacking kit. Include all Accessories as required as per site specific requirement for complete functioning.. All Accessories shall be of same Make as the OEM.
Supply, Installation, testing and Commissioning of Layer 2 Managed POE Switch- 8 ports of 10/100/1000 MBPS or more with 2 SFP Ports- Min 1GBPS - 2 Nos SFP Fiber Ports with Modules loaded & Include all required components for multiple switch stacking Kit. Include all Accessories as required as per site specific requirement for complete functioning. All Accessories shall be of same Make as the OEM.
Layer3 Switches & Components
Supply, Installation, testing and Commissioning of Layer 3 Managed Switch- 24 ports of 1GBPS SFP or more with 4 SFP Ports- Min 18 Nos SFP Fiber Ports with Modules loaded . Include all Accessories as required as per site specific requirement for complete functioning. All Accessories shall be of same Make as the OEM.
Wireless Access Points
Supply, Installation, testing and Commissioning of Access Point and All required Accessories,etc Support Wifi 6 Technology,Transfer speed Min 1400 Mbps. POE powered and Enhanced Security
ACTIVE VOICE
Supply ,installation ,Testing and commissioning of IPPBX System with 100 IP Ports
IP / SIP Licenses for IP Phones - 100 Users
IP Telephones with Key pad expansion features(Tenant office-1 No, substation-1No, Reception – 2 nos, Tide Office – 2 nos, IBMS Room – 1 no, Multipurpose Room – 1 no, and Security Room – 2 nos.)
DSS Console / Operator console/ Call Station
OFC to UTP Media Convertor - Media converter to convert 100/1000 MBPS BASE-TX ethernet twisted-pair signals to100/1000 MBPS BASE FX fast ethernet fiber signals, support full duplex ethernet mode, with two connectors one for transmission and other for reception, with RJ-45 port, two LED's for detecting the fiber link and ethernet link,fiber distance for multi mode upto 2 Km and single mode upto 15 Km, power input: 9V 1A Adapter and complete with other accessories. Unit shall be mounted in IP-66 housing.
IP 66 Weather Proof Enclosure at Poles / outside cameras with required Socket /Switches (As reqd) to accommodate Media converters, power supply & Fiber terminations etc.
3 Core x 1.5 sq mm unshielded, tinned copper , Twisted cable for power supply
TALKBACK SYSTEM
Supply ,installation ,Testing and commissioning of Single Loop ,Zone distribution Unit 20 Zone of Rack Mountable with frequency response of 150Hz-10KHz , Max input sound level 100V SPL ,Current Consumption <02 Amp ,Power Supply 230V ,50Hz ,AC supply with required accessories
Supply ,installation, Testing and commissioning of Addressable Talkback speaker with inbuilt Hooter , 6W Speaker ,Flush/Wall Mountable with required fixing accessories
Supply ,installation, Testing and commissioning of Conventional Booster Amplifier 240W
Supply and installation of Rack 9U Wall mountable with all accessories
Supply and laying of 6 core 1 Sqmm shielded flexible cable
Supply and laying of 25mm dia PVC Conduit
Building Management System
BMS Master Work Station BMS work station Shall have the following configurations and features 1) Processor - Intel® Core i7® Processor 2) Memory: 32 GB DDR4 ECC RAM or better. 3) OS - Windows 11 Professional; 64 bit 4) Networking - 2x 1GbE RJ45 Ports 5) HDD - 1 TB SATA 6) Graphics Card-4 GB or more 7) Supporting Two Monitors If vendor PC requirement is more than what is specified here, then required PC configuration to be considered for costing.
42" colour ,Flat Screen type Professional HD monitor for above client workstation
A 4 size BW Laser jet Printer suitable for the application, with driver software.
BMS Client Work Station BMS Client workstation Shall have the following configurations and features 1) Processor - Intel® Core i7® Processor 2) Memory: 16 GB DDR4 ECC RAM or better. 3) OS - Windows 11 Professional; 64 bit 4) Networking - 2x 1GbE RJ45 Ports 5) HDD - 1 TB SATA 6) Graphics Card-4 GB or more 7) Supporting Two Monitors If vendor PC requirement is more than what is specified here, then required PC configuration to be considered for costing.
42" colour ,Flat Screen type Professional HD monitor for above client workstation
Softwares for BMS System
BMS SOFTWARE: Supply, installation, testing and commissioning of the following window based graphical software for IBMS system with 1 No. Client for Operator workstation. The Software shall have 3D & HD vector dynamic graphics with Autocad import of plan with Zoom In & Zoom Out facility, Native 64 Bit System, Multi-Monitor Support-( Max 4 Nos), Multi-language support, BTL, UL, EN Certified System, BACnet Profile B-AWS (Advanced workstation) as per the BTL Listing, dot net platform, Certified OPC DA Server by OPC Foundation, Web-Based Server software shall permit use of Standard Web-Browsers such as Microsoft Internet Explorer, Netscape Navigator, etc. The Software shall comply to international standards and strive to deliver products that meet security standards such as ISA/IEC 62443, UL2900, ISO/IEC 27001, ISO/IEC62443 and OWASP. Cybersecurity audit trail, 4-eye principle, Seamless integration of certificates within customer IT infrastructure, Microsoft’s active directory-based authentication, Use of network infrastructure that supports physical network or VLAN segmentation, Placing the web server in a “demilitarized zone” (DMZ), End-to-end encryption, from client to server, End-to-end encryption between servers, Certificate-based data exchange, Encrypted backups. The Software shall be considered for 2500 IO Points and cablaple of connecting minimum of 5 Client License. Include Eenrgy Billing software for the Tenant Billing with required customisation as per the client requirement. Special Note - The Software should have cloud connectivty and can be access remotively using User Name and Password from anywhere. For further compliance vendor to follow the Tender specifications ( Total 2500 IO points and expandaple upto 4500 IO Points )
Client version BMS software for "Monitor & Control" application, complete with Advance Graphics for Realtime Graphical Depiction of the Statuses and Controls as per the Detailed IO Summary .
SMS & E-mail alarm notification module with unlimited user capability,SMS Paging & Email Facility for transmitting specified alarms to designated personnel.
GPRS / GSM Modem of 4G / 5G Modem
Internet Router Which can support upto 100 MBPS Speed
SITC of Serial interface Controllers with Enclosure for High Level integration with following 3rd Party Equipment's as mentioned in the data point summary.
The system will warrant an Exclusive, Dedicated Serial Interface Controoler / RS 485 Port for every single individual 3rd party system (No other 3rd Party Integration shall be clubbed with any one integration ) The Interface controller shall be Capable to Integrate Open protocol systems on BACnet MSTP , Modbus RS 485, M-Bus , KNX Protocal Made available on serial RS 485 / 232 interface. ( Should have Minimum of 2 nos Ethernet Port, 2 nos RS485 Port, 1 no KNX Port ) . The Integration controller should be capabale of connecting minimum of 500 IO Points.
VRF integration - 1
Fire Alarm Panel - 1
Energy meter integration - 100
UPS integration -2 (To be connected in DDC)
DG integration-2 (To be connected in DDC)
WTP integration-1 (To be connected in DDC)
STP integration-1 (To be connected in DDC)
RO Plant integration-1 (To be connected in DDC)
LIFT Integartion - 3 (To be connected in DDC)
Solar Integartion - 2 (To be connected in DDC)
SITC of DDC Controller with Enclosures. The DDC Controller to be True IP Based DDC Standalone 32 Bit Intelligent, inbuilt web browser, peer to peer communication, interoperable DDC as per the specification. The DDC controllers should have minimum of 24 onboard IO Points , and expandadaple upto 80 Physical IO points by using IO Modules , with minimum of 120 IO Points combined physical and soft IO points. The DDC controller should have minimum of 2 nos RS485 port for Integartion of any 3 rd party protocal such as BACNET MSTP / MODBUS / MBUS.
The controller shall have inbuilt 2-port Ethernet switch. The DDC shall have 300 Mhz processor with 128 MByte SDRAM (DDR3) and 512 MByte NAND Flash. The DDC shall have IT security including HTTPS and BACnet Secure Connect communication, Operating voltage AC 24 V. The controller shall be freely programmable and have System functions (alarming, scheduling, trending, access protection with individually definable user profiles and categories). Each DDC shall have WLAN interface for local operation, engineering and commissioning. It should have one integration port inbuilt and port for POT for local interface. For further compliance vendor to follow the Tender specifications . Automation stations / DDC Controller with I/O module etc., The controllers shall be NATIVE BACNET IP based. The controller shall be with 32 bit microprocessor, working in standalone or networkable mode, with real time clock and historical database & Peer to Peer Communication. The controller should have minimum of 24 IO Points with inbuilt Port for RS485 communication. The DDC's shall store programs and program parameters in non volatile memory. The DDCs shall be housed within a suitable powder coated MS enclosure complete with all protection, terminals, wiring and accessories as mentioned.
DDC Panel for Toilet Exhaust fans & Liftwell Pressurazation fans
DDC Panel for Electrical Panel Monitoring - UPS integration -2
DDC Panel for Fire pumps - DG integration-2 & WTP integration-1
DDC Panel for Water Tanks - LIFT Integartion - 3 & Solar Integartion - 2
DDC Panel for PHE Pumps - STP integration-1 & RO Plant integration-1
Field Devices - SITC of following Field devices wit necessary accessories
Outdoor Air Temperature & RH sensor
Water Level Transmitter - Hydrostatic type to measure the tank level
Room type Temperature & Humidity Sensor
230 V Realy with 2 NO NC for status monitoring
Media Convertor from RS 232 / 485 / Ethernet for Integration
Cabling and Containment
Supply and Laying of following cables for instrument, controls, valves to DDCs and communication cabling from DDC to central equipment complete with earthling, supports etc. complete. Laid on Surface / On Cable Trays. All Cables shall be ATC,PVC Insulated, unarmoured , Tinned Copper, Twisted Shield cable ferruled and tagged, and shall use lugs for termination at both ends.
2 Core x 1 sq. mm Screened with drain wire, Cable for control cabling
2 Core x 1.5 sq. mm Screened with drain wire, Cable for Integration
4 Core x 1 sq. mm Screened with drain wire, Cable for control cabling
3 Core x 1.5 sq. mm unshielded, tinned copper , Twisted cable for power supply
Cat 6e Communication cable as per IEEE Standards
4 Core Armoured Optic Fibre cable
Perforated GI cable tray with Cover : Supply and laying of following sizes of Perforated cable tray complete with supports, all fittings and mounting accessories, etc. complete to installation requirements.- DDC Panel cable dressing
100 mm x 50 mm x 2mm
150 mm x 50 mm x 2mm
Supply & Laying PVC- FRLS conduits complete with all fittings and accessories
25mm PVC conduit
19mm PVC conduit
NETWORK SWITCHES
SITC of Network Switch : 24 port layer Network switch with 10/100/1000 Mpbs with 24-Port Gigabit Smart Managed Switch with 4 Gigabit RJ45/SFP COMBO ports
Equipment Racks
24U Rack - 19" type Equipment racks for mounting the Servers/ Switches in the BMS Equipment Room, & for mounting field mounted Switches at every Floor. Racks shall be complete with Modular Patch Panels for Patching the Field Cables ( Cu and FO) with the Edge Switches on floor as required. Racks shall be provided with Dual Power A&B, and should have 2 PDU Strips, Redundant Fans and Door to have Tamper Switch.
Any other accessories required to complete the system configuration as per vendor specific requirements i.e. Power supplies,fiber converters, LIUs, Specific System cables etc. to complete the installation. Contractor to mention the quantity of the below items with cost apart from the below item if any other acceroiers are required , controator to add the same Patch Panels,1mtrs Cat6 Patch Cords LIU’s Pigtail cables 1mtr LC to LC Single Mode Patch Cords,Labels,any Other component to complete the design intent
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.61 MB
Volume1Karur.pdf
Tender Documents • 0.95 MB
Volume2Karur.pdf
Tender Documents • 3.46 MB
Volume5ABKarurCivilandStructural.pdf
Tender Documents • 28.50 MB
Volume3KarurTechnicalspec.pdf
Tender Documents • 11.19 MB
BOQ_792962.xls
BOQ • 2.89 MB
Volume5CKarurMEPF.pdf
Tender Documents • 33.76 MB
Download all tender documents and submit your bid