Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹95,648Accepted-AOC ARACKAL H VARAPPETTY P O KOTHAMANGALAM 686691 | ERNAKULAM | KERALA | 686691 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹98,500+₹2,852 (2.98%)Rejected-AOC | L2 | Rejected-AOC Second lowest |
Tender Value
Refer Docs
EMD Value
₹2,410
Closing Date
21 Nov 2024, 3:00 pmClosed
Assistant Executive Engineer
Office of the Assistant Executive, Electrical wing irrigation Sub division Aluva
GENERAL-MVIP Action plan 24-25-MVIPMalankara Dam fully comprehensive annual maintenance of shutter motors and other connected electrical installation at Malankara dam Electrcial work for the year 2024-25- General Electrical Work
2024_Irrig_688736_3
PWD/MVIP/BLDG/5487/2024-2025
Open Tender
Electrical Works
Item Rate
365 days
Thodupuzha
Please refer Tender documents.
11 documents required · 11 mandatory
₹555
₹2,410
27 Dec 2024
12 Nov 2024
23 Nov 2024
12 Nov 2024
21 Nov 2024
12 Nov 2024
Amount
Overhauling
OD7370/2024-2025:Dismantling the 5HP motor into stator and rotor, cleaning the windings, attending minor repairs, retaping the coils if necessary, varnishing the coils with best quality insulation varnish, cleaning and greasing the bearings with Lithium base grease, heating and baking the windings, reassembling, test running including scrapping, cleaning and painting with 2 coats of Grey enamel paint.
OD7373/2024-2025:Supplyl of the LED Indication lamps Red, Green, Black, Yellow, Orange colours LED indicator, AC/DC, 22.5 mm cut out dia in panel board after dismantling the damaged one
OD57606/2024-2025:Supply of Blue colour LED indicator, AC/DC, 22.5 mm cut out dia in place of damaged one
2.1.1:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP & N
90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
OD7376/2024-2025:Supply and filling of battery water to the battery bank of the existing solar energy conversion system and refilling batteries of generator if needed
OD7377/2024-2025:Supply of 63 A HRC fuse link for replacement of damaged fuse link in ssb 1 and ssb2 in the control rooms
OD7378/2024-2025:Supply of 20 A HRC fuse link in the panel for replacing the damaged fuse link
OD56615/2024-2025:Disconnect all electric connections from the motor , decoupling the motor from pump and remove the base bolts from motor and base plate and kept the motor at safe place , checking and testing the stator and rotor winding. power 5 HP leading the motor to the nearest roadside using manpower, rope , chain, reaper etc. as required without getting damages to the motor, including loading into the vehicle and unloading at workshop for repairs and to and fro conveyance.
OD56616/2024-2025:Charges for rewinding the burnt rotor/stator - separate stater and rotor/stator, dismantling the damaged rotor/stator winding from the rotor/stator slots, cleaning the slots neatly, insulating the slots with correct class of insulating paper, winding the rotor/stator with good quality correct gauge of super enamelled copper winding wires, closing the rotor/stator slots with fibre wedges, putting proper inter layer insulation, connecting the coil end connection, providing new rotor/stator lead wire, steel binding the overhang with proper insulation at both ends, heating the coils and varnishing with good quality insulation varnish, keep it for drying, reassembling and test running(Less scrap copper)
OD56883/2024-2025: Supply and installation of solar charger PCB of Havells Enviro 3 KVA model SI 3000PRO in place of damaged solar charger board
OD56885/2024-2025:Supply and installation of 9 W led bulb
OD57641/2024-2025:Supply of cont-actor of rating 9A for replacing the damaged one in the starter panel of canal shutter motors and giving connection etc. as required
OD57767/2024-2025:Supply of overload relay in place of damaged one L&T make MN2 relay and giving connection as required.
OD59885/2024-2025:Supply and installation of 23 W 3 star rated led bulb in the existing post top fittings in place of damaged one
Periodical Maintenance
OD56933/2024-2025:Annual maintenance of all motor, Main panel and sub control panel - 2 nos and starter panels of canal shutter motors and DBs which inlcudes periodical cleaning of panel with blower and Checking and tightening of cable terminations of all the incoming & outgoing feeders of all the panels. Checking & tightening of all the control cables of panels and .Checking the proper operation of switch gear items and attending all the minor repairs like changing damaged beeding and smc sheets and changing damaged knobs of all switch gear compartments and changing led indicators and push buttons and changing cont actors and relays in starter panel of canal shutter motors and voltmeters and ammeters and fuse links and Switch gears if needed ( excluding supply of ammeters and volt meters and indicators conatctors and relays) )and checking earth connection, attending repairs to all the compound lights including street light and flood lights including checking the fault and attending minor repairs( excluding fittings), and ensuring trouble free operation for a period of 12 months
generator 82 .5 kva servicing
OD57786/2024-2025:Supply and renewal of Fuel filter suitable for 82.5kVA DG set after dismantling the old one.
OD57787/2024-2025:Supply and renewal of Oil filter suitable for 82.5kVA DG set after dismantling the old one.
OD57788/2024-2025:Supply and renewal of Air filter assembly suitable for 82.5kVA DG set after dismantling the old one.
OD57789/2024-2025:Supply of fan belt for 82.5kVA DG set
OD57790/2024-2025:Supply of radiator coolent for 82.5kVA DG set
OD57791/2024-2025:Supply of engine oil for topping up if required for 82.5kVA DG set
OD57785/2024-2025:Labour charge for overhauling and servicing of 82.5kVA DG set including conveyance and replacing the damaged spares( fuel engine oil, changing and fuel filter and oil filter change, air filter change, fan belt renewal, battery water, coolant filling) checking the internal connections, tightening joints, removing deposited dust and carbon particles. Cleaning fuel tank, fuel line, radiator and connection hose checking leakage and replacing if reaquired, taking trial run on full load.
ALIYAR T K (BID ID -1984527)
Bidder Name
A. R Sivasankaran
ALIYAR T K
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1102369.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .