| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.3 LAccepted-AOC 33 JAGGI GARDEN NARAINGARH ROAD AMBALA CITY 134003 | AMBALA | HARYANA | 134003 | L1 | Accepted-AOC AOC | |
| 2 | L2₹27.1 L+₹18,652.80 (0.69%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹27.4 L+₹48,347.40 (1.79%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹27.4 L+₹48,381.90 (1.80%)Rejected-Finance | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹27.7 L+₹71,815 (2.67%)Rejected-Finance | L5 | Rejected-Finance Not lowest bidder |
Tender Value
Refer Docs
EMD Value
₹54,000
Closing Date
9 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NORTH) AMBALA CANTT
GE (NORTH) AMBALA CANTT
GE(N)AMB-59(P)/2020-21 PROVN OF CERTAIN SANCTIONED WORKS UNDER AGE B/R-I GE (NORTH) AMBALA CANTT
2020_MES_371139_1
GE(N)Amb-59(P)/2020-21
Open Tender
Civil Works
Item Rate
182 days
GE (NORTH) AMBALA CANTT
As Per Tender Documents
7 documents required · 7 mandatory
₹500
GE (NORTH) AMBALA CANTT
₹54,000
Yes
17 Feb 2021
12 Jan 2021
11 Feb 2021
12 Jan 2021
9 Feb 2021
26 Jan 2021
12 Jan 2021 - 26 Jan 2021
60 days
Amount
Schedule 'A' part-I ie B/R items
Surface excavation (not exceeding 30cm deep) and averaging 15 cm deep, getting out in soft/loose soil complete all as specified and as directed by the Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation etc or for shafts, wells, manholes etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed by the Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and exc 1.5 m & not exc 3.00m depth for foundation etc or for shafts, wells, manholes etc. n exc 10 sq m on plan and exc 1.5 m & not exc 3.00m in depth and getting out in soft/ loose soil complete all as specified and as directed by the Engineer-in-Charge.
Excavating or areas, not exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed by the Engineer-in-Charge.
Excavating or areas, exc 1.5 m and not exc 3.00m in depth and getting out in soft/ loose soil complete all as specified and as directed by the Engineer-in-Charge.
Returning, filling in, including spreading, levlling ,watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer-in-Charge.
Surface dressing not exceeding 15 cm deep, getting out in soft/loose soil complete all as specified and as directed by the Engineer-in-Charge.
M & L sand filling under floor or in foundation including watering and consolidation complete all as specified and as directed by the Engineer-in-Charge.
Removing surplus excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
M&L broken stone hardcore of gauge not exc. 63mm, deposited , spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and as directed by the Engineer-in-Charge.
M & L PCC 1:4:8 Type D2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M & L 100 mm thick PCC 1:4:8 Type D2 using 40mm graded crushed stone aggregate as in sub base of floor/ hard standing etc and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M & L providing cement concrete 1:2:4 Type B1 using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed by the Engineer-in-Charge.
M & L PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in padding, filling in roof deprerepstion, mud stops, roof kerbs on roof slab including fromwork whereever required complete all as specified and as directed by the Engineer-in-Charge.
M & L precast RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in CM 1:6 complete with joints to match, except blocks or slabs complete all as specified and as directed by the Engineer-in-Charge.
Supply only integral water proofing compound complete all as specified and as directed by the Engineer-in-Charge.
M&L for brick work with sub class 'B' old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M&L for brick work with sub class 'B' old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M & L brickwork with sub-class `B` bricks in half brick thick wall straight or curved on plan to any radius built in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge
M & L damp proof course to horizontal or vertical surfaces including necessary formwork, 40mm thick, in cement concrete 1:2:4 type B0 using 12.5mm graded crushed stone aggregate complete all as specified and as directed by the Engineer-in-Charge
Cutting chases ,pinning in making good to facing where required and pointing in CM 1:3 to edges of landing , steps , cills , sunshades, shelves , lintel etc. and cutting chases for concealed water tubing etc and making good cutting not exc 10 cm girth complete all as specified and as directed by the Engineer-in-Charge.
M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), work in rough finished flat surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge
M & L formwork to chullah hoods, chajjas, weather shades, corbels, water troughs and similar items including edges, work in rough finished flat surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge
M & L formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports overhangs etc, also splays between floors and beams, etc., work in rough finished flat surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge
M & L formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, for roughed finished surface of concrete complete all as specified and as directed by the Engineer-in-Charge
M & L second class soft wood, timber fixed and clean sawn as in scantlings complete all as specified and as directed by the Engineer-in-Charge
M&L 35 mm thick 2nd class hard wood glazed and skeleton shutters,open rebated and prepared to receive glass , gauze etc. (without sash bars) ,edges of framing plain chamfered or rounded , fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR Part-I, Section-8, clause 8.24 (a) (wood shall be seasoned and chemically pressure treated) complete all as specified and as directed by the Engineer-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from frames) exc 1.5 sqm but not exc 4 sqm each and removing from site complete all as specified and as directed by the Engineer-in-charge.
S & F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube fixed in opening complete all as specified and as directed by the Engineer-in-Charge.
S&F factory made solid PVC moulded door shutters with partical board core 28 to 30 mm thick (styles) with 2, 4, or 6 raised panel design with 2 mm thick prelaminated moulded PVC sheet on the front face and 2mm thick plain colour PVC sheet on back face fixing in frame at site as per specification and drawing complete all as specified and as directed by the Engineer-in-Charge.
S&F 200 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F 125 mm long aluminium handle cast type anodised complete all as specified and as directed by the Engineer-in-Charge.
S&F, aluminium alloy anodised sliding door bolts , of 300 mm long with hasp,staple(bolt type) and fixing clips of sheet, cast or extruded section , fixing bolts and sliding bolts of extruded section and fixed, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing aluminium butt hinges 100 mm long medium weight cold rolled galvanised mild steel hinges pin and fixed complete all as specified and as directed by the Engineer-in-Charge.
S & F brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed by the Engineer-in-Charge
M&L mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar; barred iron doors; ladder; framed balusters; railing;frame work for water tanks and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed by the Engineer-in-Charge.
S & F for 1.25mm thick mild steel, plain & black sheet in wall cladding, steel gates and similar work; cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles etc. as required complete all as specified and as directed by the Engineer-in-Charge
M&L TMT mild steel bars 10mm dia and over cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
M&L TMT mild steel bars 6 to 8mm dia, cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
M & L mild steel TMT bars 6 to 8mm dia and over upto including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by the Engineer-in-Charge
M & L plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410-(Gde E-250) quality 'A' complete all as specified and as directed by the Engineer-in-Charge.
M&L rolled mild steel framed work as in door or gates of angle or other section with gusset plates, rails braces etc. complete. drilled for fixing for steel sheeting or other covering doors, etc to be prepared for hanging or sliding with and including either hooks and hinges and hanging ,door fitting (exclusive of steel sheeting or other covering, running rails and guides) also fastening and fixing including one shop coat of zinc chromate primer conforming to Fe-410-(Gde E-250) quality 'A' complete all as specified and as directed by the Engineer-in-Charge.
S&F steel ventilator box type top hung shutter with partly gauge and partly glazing bar complete all as specified and as directed by the Engineer-in-Charge.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick with Az-150 coating of any colour having tensile strength 550 Mpa as in roof covering , fixed with self tapping screws complete all as specified and as directed by the Engineer-in-Charge.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick with Az-150 coating of any colour having tensile strength 550 Mpa as in roof covering , fixed with self tapping screws complete all as specified and as directed by the Engineer-in-Charge.
M & L 6mm thick plywood (05 Nos ply), grade BWR, type BB, fixed with screws to timber frame work complete all as specified and as directed by the Engineer-in-Charge.
M&L for 18/19 mm thick prelaminated partical board interior grade prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screw to timber frame work/aluminium frame work complete all as specified and as directed by the Engineer-in-Charge.
M & L machine cut kota stone slab flooring 18 to 22 mm thick of size not less than 550mm x 550mm in floor, set and jointed in neat cement slurry with grey cement mixed with pigment to match the shade of the slab including rubbing and polishing (granite finish) over and including 15 mm thick screed bed in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M & L machine cut kota stone slab 18 to 22 mm thick of size not less than 550mm x 550mm in skirting/dado etc, set and jointed in neat cement slurry with grey cement mixed with pigment to match the shade of the slab including rubbing and polishing (granite finish) over and including 10 mm thick screed bed in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M&L Marble Baroda green 16-18mm thick in one piece in width and length less than 1.8 metre (except in case of slab is more than 1.80 metre and less than 2.40 metre smaller size as approved by Engr-in-Charge may be used) table rubbed & polished as in cooking platform/window cills etc over and including 15mm thick bedding layer in CM 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble incl rounding of front edge and finally granite finish polishing complete all as specified and as directed by the Engineer-in-Charge
M & L 75 mm thick PCC 1:3:6 Type C2 using 40mm graded crushed stone aggregate as in sub base complete all as specified and as directed by the Engineer-in-Charge.
M & L providing 75 mm thick cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight including form work complete all as specified and as directed by the Engineer-in-Charge.
M & L 75 mm thick PCC 1:4:8 Type D2 using 40mm graded crushed stone aggregate as in sub base of floor/ hard standing etc and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M & L 25mm thick plain cement concrete 1:2:4, type B-0 using 12.50mm graded crushed stone aggregate as in bedding layer under floor surface finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L machine pressed rubber moulded precast coloured concrete interlocking paver block, any shape and size conforming to IS 15658-2006 of 60 mm thickness grade M-35 with grey cement and pigments over and including a layer of sand cushioning, 25 mm thick complete all as specified and as directed by the Engineer-in-Charge
M & L chequired cement concrete tiles 25cm x 25cm x 22mm thick, machine pressed, set, jointed and pointed in neat cement slurry with grey cement and no pigments in path over and including 15mm thick screed bed (1:4) complete all as specified and as directed by the Engineer-in-Charge
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing servicable tiles to store and rubbish off the premises complete all as specified and as directed by the Engineer-in-Charge
M&L vitrified ceramic light shade tiles 1st quality (square/rectengular), 10mm thick, area of each tile exc 0.36 sqm but not exc 0.42 sqm as in floors, set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including screed bed or bedding layer 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and as directed by the Engineer-in-Charge.
M&L vitrified ceramic light shade tiles 1st quality (square/rectengular), 10mm thick, area of each tile exc 0.36 sqm but not exc 0.42 sqm as in skirting/dado, set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including screed bed or bedding layer 10 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and as directed by the Engineer-in-Charge.
M&L glazed ceramic coloured tiles joint free1st quality (square/rectengular) 7mm thick, area of each tile exc 0.11 sqm but not exc 0.18 sqm in vertical surfaces/skirtings/dados, set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match over and including 10mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
M&L Non-skid ceramic coloured tiles joint free 1st quality (square/rectengular) 7 to 8 mm thick, area of each tile exc 0.11 sqm but not exc 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including screed bed or bedding layer 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and as directed by the Engineer-in-Charge.
M&L Non-skid ceramic coloured tiles joint free 1st quality (square/rectengular) 7 to 8 mm thick, area of each tile exc 0.11 sqm but not exc 0.18 sqm as in skirting/ dado, set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including rendring 10 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and as directed by the Engineer-in-Charge.
S & F 15mm bore cast copper alloy chromium plated fancy stop valves, screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
M & L preparing roof surfaces and applying water proofing treatment over roofs comprising of the following,Complete all as specified & as directed:- (i) Applying oil bound bitumineous primer at the rate of 0.40 Liters/Sqm as per IS 3384-1986 on prepared surfaces.Surface shall be kept free till the moment, the primer is impregnated and the solvent oil in primer is evaporated. (ii) Laying 3mm thick APP polymeric water proofing membrane of weight not less than 3.6 Kg/Sqm, black finished reinforced with non woven polyster matt, with a thermo fusible finish,torching overlaps with a propane or butane gas torch, with a overlap of 75mm at sides and 100mm at the ends,and sealing including applying a coat of cold emulsion bitumineous primer all as per manufacturer's instruction including prepration of surface. (iii) Applying one coat of hot straight run bitumen grade 30/40 (Grade S-35) confirming to IS -73 at the rate of 1.2 Kg/Sqm. Note:- The water proofing treatment shall be carried out by manufacturer or his authorized applicators in terms of clause 11.43 of MES Sch Part-'I' (2009)
S & F fancy type bib tap 15mm bore cast copper alloy chromium plated log body with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing steel window box type using ERW hollow 'P' section comprising double frame for and including gauged and glazed skelton shutter 30mm thick, jointed internally with flat iron 25x3mm complete including hinges, handle, tower bolts, stops, lugs, guard bars and painting etc. all as shown on drawing No. TD-219 sheet 1/3 to 3/3 and TD-220 sheet 1/3 to 3/3 as applicable complete all as specified and as directed by engineer in charge. Note: (i) For the purpose of measurement and payment double shutter both glazed and gauzed with frames shall be considered as one unit. (ii) Unit rate quoted against this item shall also include the iron mongery and grill as shown on drgs. (iii) Glazing, wire mesh shall be measured and paid for separately. complete all as specified and as directed by the Engineer-in-Charge.
S & F 15mm bore cast copper alloy chromium plated stop valves, screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S & F 20mm bore cast copper alloy chromium plated stop valves, screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S&F 100mm bore cast iron (sand cast) soil, waste and vent pipes in any length with or without ears, with cement joint, laid in trenches complete all as specified and as directed by the Engineer-in-Charge.
S&F 50mm bore cast iron (sand cast) soil, waste and vent pipes in any length with or without ears, with cement joint, fixed to wall complete all as specified and as directed by the Engineer-in-Charge.
S&F 75mm bore cast iron (sand cast) soil, waste and vent pipes in any length with or without ears, with cement joint, laid in trenches complete all as specified and as directed by the Engineer-in-Charge.
S & F 100mm bore bends of any radius, diminishing pieces or tapers (larger bore measured) complete all as specified and as directed by the Engineer-in-Charge.
S & F 75mm bore bends of any radius, diminishing pieces or tapers (larger bore measured) complete all as specified and as directed by the Engineer-in-Charge.
S & F PVC connections 45 cm long with PTMT nuts at both ends complete all as specified and as directed by the Engineer-in-Charge.
S & F 50mm bore cast iron vent cowl etc complete all as specified and as directed by the Engineer-in-Charge.
S & F 75mm bore cast iron vent cowl etc complete all as specified and as directed by the Engineer-in-Charge.
M & L cutting into existing manholes for connecting new drain, making good to pipe 100 mm dia and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required complete all as specified and as directed by the Engineer-in-Charge.
Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified and as directed by the Engr-in-charge.
Dismantling of 100 mm bore cast iron or reinforced concrete drain pipes jointed in cement mortar and taking out of trenches, floor and wall complete all as specified and as directed by the Engr-in-charge.
Demolition of Cement concrete (un-reinforced) in ground floors and pavings n exe 15 cm thickness (below or above ground level) complete all as specified and as directed by the Engineer-in-Charge.
S&F vitreous china wash down water closet pan ( pedestal pattern) white including connection to out going pipe and to flushing pipe and antysyphonic pipe etc including plastic water closet seat,white, closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed by the Engineer-in-Charge.
S & F vitreous china wash hand basin white, flat back of size 580mmx450mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of waste fitting etc complete all as specified and as directed by the Engineer-in-Charge.
M&L brick work with sub class 'B' old size bricks using old servicable bricks including cleaning of old bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge.
Dismantling wall and ceiling boards (fiber pulp, insulation etc) or insulation boards/ slabs/blankets any thickness including cover fillets and false ceiling frame /gird of any type/any description, fixed in position,complete all as specified and as directed by the Engineer-in-Charge.
S & F 605x605 mm anodised aluminium powder coated snap grid frame work for false ceiling including fixing of arrangement including hanging. The snap grid shall be consist of aluminium main and cross tee of size 24mmx32mmx 0.30mm and 15mm x32mmx0.30mm respectively, the size of aluminium angle and cleats etc shall be as specified in SSR Part-I (2009). The snap grid frame shall fixed to ceiling with supporting hangers consisting of 4 mm dia GI wire with necessary bolts, nuts and washers including laying 4mm thick designer decorative type asbestos cement ceiling board ('E' Board) including two coats of acrylic emulsion paint over a coat of cement base primer complete all as specified and as directed by the Engineer-in-Charge.
S & F 10 ltr PVC valveless syphonic action type flushing cistern with brackets, flush pipe etc complete including inlet ball valve float and handle including brackets, of approved make including all connections & flush pipes for WC complete all as specified and as directed by the Engineer-in-Charge.
M & L figured glass 3.00mm thick pin head type and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and as directed by the Engineer-in-Charge.
S & F 20mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe and fixed (minium weight-210 grams) complete all as specified and as directed by the Engineer-in-Charge.
M & L galvanised iron tubing 15mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
S & F galvanised iron tubing 20 mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
M & L sheet glass 3.00mm thick ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and as directed by the Engineer-in-Charge.
M & L sheet glass 5.00mm thick ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing grating doom 100 mm dia of PTMT (minimum weight 25 gms) complete all as specified and directed by Engineer-in-Charge.
M & L concrete bed in PCC 1:4:8 type B2 using 40 mm graded crushed stone aggregate to drain pipes including packing under and haunching against the sides of pipes, after they are laid and tested for 150 mm dia (internal) PVC (SWR) pipes complete all as specified and as directed by the Engineer-in-Charge. (Pipes shall be measured & paid separately).
S & F vitreous china squatting pan, Orissa pattern, of size 580 mm x 440 mm white with integral foot rest complete including provn of cement concrete bedding and connection to trap, outgoing flushing pipe, anti syphonage pipe, including cast iron 'S' trap 100 mm bore complete all as specified and as directed by the Engineer-in-Charge.
M&L preparing new plastered surfaces and applying two coats of cement base paint on surfaces of walls over a coat primer complete all as specified and as directed by the Engineer-in-Charge.
M&L preparing new plastered surfaces and applying two coats of oil bound distemper with painting roller over a coat of primer on surfaces of walls complete all as specified and as directed by the Engineer-in-Charge.
M & L preparing new plastered surfaces of wall and applying two coats of oil emulsion distemper with painting roller over and including 3mm thick wall care putty in two or more coats to achieve smooth surfaces complete all as specified and as directed by the Engineer-in-Charge.
M & L preparation of new steel and iron surfaces of any description, not otherwise dscribed, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by the Engineer-in-Charge.
M & L preparation of new wooden surfaces of any description, not otherwise dscribed, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed by the Engineer-in-Charge.
M & L complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers or any other means, wasing down with water to remove loose particles etc, filing of cracks with white cement and fine sand in ratio of 1:3 and applying two coats of oil emulsion distemper with painting roller over and including 2 to 3 mm thick wall care putty in two or more coats to achive smooth surfaces over and including one coat of primer complete all as specified and as directed by the Engineer-in-Charge
M&L preparation of newly plastered/ unplastered surfaces of walls and applying two coats of oil bound distemper with painting roller over and inlcuding 2mm to 3mm thick wall care putty in two or more coats to achive smooth surface complete all as specified and as directed by the Engineer-in-Charge.
M & L complete removal of existing treatment on walls (any number of layers) by scrapping with steel scrappers or any other means, wasing down with water to remove loose particles etc and applying two coats of oil emulsion distemper with painting roller over and including 2 to 3 mm thick wall care putty in two or more coats to achive smooth surfaces complete all as specified and as directed by the Engineer-in-Charge
M&L preparation of old decorated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coat of synthetic enamel paint complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of old decorated wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coat of synthetic enamel paint complete all as specified and as directed by the Engineer-in-Charge.
M & L 75 mm thick PCC 1:2:4 type B2 using 40mm graded crushed stone aggregate as in floor/ hard standing etc and finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Supply & fixing pillar tap 15mm bore, cast copper alloy with capstan heads, chromium plated, screwed down, high pressure, with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed by the Engineer-in-Charge.
M&L rendering 10 mm thick on fair faces of brick work or concrete ceiling surfaces in cement mortar 1:3 and finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M & L rendering 15 mm thick on external surfaces of brick work or concrete wall surfaces in cement mortar 1:4 and including mixing water proofing compound @ 2% by weight of cement or as per manufacturer's instruction and finished fair and even without using extra cement complete all as specified and as directed by the Engineer-in-Charge. (WPC shall be measured and paid for separately)
M & L rendering 15 mm thick on other than fair faces of brick wall or concrete surfaces in CM 1:6, finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge
S&F kitchen plate rack of stainless steel sheet 1mm thickness size 900mm x 750mm x250mm and having weight not less than 8.00 Kg each complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing factory made uPVC white Sliding window area n.exc 2.00sqm, three track made of extruded profiles with wall thickness of 2.3mm (+/-0.2mm). Window profile with hollow section with multi chamber, frame (88mm x 52mm), sliding sash (42mm x 67mm), Sliding mesh Sash (42mm x 57mm), Sliding Interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be mitered cut and fusion welded at all corners, including railing of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM gasket, 1.2+/ -0.2mm thick galvanized steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners. hardware: [Touch Lock of zinc alloyed (white powder coated), steel roller system, Stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.14mm and required accessories. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.)
S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed on walls complete all as specified and as directed by the Engineer-in-Charge
S & F 150mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed by the Engineer-in-Charge
S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed to wall complete all as specified and as directed by the Engineer-in-Charge
S&F PVC(SWR) bends of any radius, for 110mm bore pipes, with access doors complete all as specified and as directed by the Engineer-in-Charge.
S & F 75mm bore PVC (SWR) bends of any radius with access doors complete all as specified and as directed by the Engineer-in-Charge.
S&F 75mm bore PVC (SWR) vent cowl etc complete all as specified and as directed by the Engineer-in-Charge.
S & F 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed by the Engineer-in-Charge
M&L reinforced cement concrete 1:1-1/2:3 (Nominal Mix) using 20mm graded crushed stone aggregate in chajjas complete all as specified and as directed by the Engineer-in-Charge.
M & L reinforced cement concrete 1:1-1/2:3 (Nominal Mix) using 20mm graded crushed stone aggregates as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L reinforced cement concrete 1:1-1/2:3 (Nominal Mix) using 20mm graded crushed stone aggregate in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by the Engineer-in-Charge.
M&L reinforced cement concrete 1:1-1/2:3 (Nominal Mix) using 20mm graded crushed stone aggregates in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed by the Engineer-in-Charge.
M & L roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etcand applying need cement slurry @ 3kg per sqm, complete all as specified and as directed by the Engineer-in-Charge.
S&F brass chromium plated shower rose 125mm size with or without swivel joint with arm of standard size as per site complete all as specified and as direced by the Engineer-in-charge.
S & F sinks without drainage board made out of stainless steel 1mm thick sheet for kitchen with plugs, waste pipe, brass chromium plated coupling and wastes; in-cluding bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connect-ing union to pipe overall size 495mm x 420mm with bowl size 410mm x 330mm x 160mm complete all as specified and as directed by the Engineer-in-Charge
S & F soap dish, brass chromium plated, approximate size 160x160x90mm, fixed to plugs with chromium plated brass screws complete all as specified and as directed by the Engineer-in-Charge
M & L stack clamp out of 50mm x5mm flat iron stays including bolt and nuts and securing ends of stays to walls or roof for 100mm bore pipe complete all as specified and as directed by the Engineer-in-Charge..
M & L stack clamp out of 50mm x5mm flat iron stays including bolt and nuts and securing ends of stays to walls or roof for 75mm bore pipe complete all as specified and as directed by the Engineer-in-Charge..
S & F 500 litres rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) 100% UA stablised, rust proof, hoisted and fixed in position all as specified in SSR Part-I complete all as specified and as directed by the Engineer-in-Charge Note:- Tank shall be in white colour.
M & L taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed by the Engineer-in-Charge
M & L taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed by the Engineer-in-Charge
M & L taking down cement or cement lime plaster of any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by the Engineer-in-Charge
S & F vitreous china urinal, half stall type white (excluding flushing cistern, flush pipe) but including brass chromium plated spreader, PVC waste pipe , providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement flush pipe, grating and union for discharge pipe. (exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and as directed by the Engineer-in-Charge.
S & F 32 mm bore Low density polyethylene pipes (LDPE)of pressure rating 6kgf/cm2 in standard length suitable for WHB and sink complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of newly plastered/ unplastered surfaces of concrete ceiling and applying three coats of white lime wash complete all as specified and as directed by the Engineer-in-Charge.
Taking down shutter from the frame exc 1.00 sqm but not exc 2.00 sqm each and refixing in the same opening including adjusting as per opening complete all as specified and as directed by the Engineer-in-charge.
M&L preparation of old surfaces of brick/concrete ceiling and applying one coat of white lime wash complete all as specified and as directed by the Engineer-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exc 1.5 sqm each and removing from site complete all as specified and as directed by the Engineer-in-charge.
S&F Galvanised mild steel wire cloths 0.56 mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tack or galvanised wire staple complete all as specified and as directed by the Engineer-in-Charge.
M&L 2nd class hard wood 35 mm thick plain framed panelled shutter( two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on boths face . The size of rail and style as per IS:1003 (Part-1) kiln seasoned and chemically pressure treated complete all as specified and as directed by the Engineer-in-Charge.
S&F mild steel 150 mm ordinary rat tail rod pattern springs including roller and roller plate etc complete all as specified and as directed by the Engineer-in-Charge.
Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and as directed by the Engineer-in-Charge.
S & F in repair mild steel powder coated wooden finish curtain rod 25mm dia fixed with and including decorative brackets ,stop roller and glass at the end etc complete all as specified and as directed by the Engineer-in-Charge.
Hacking out old broken glass (any thickness,size,quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed by the Engineer-in-Charge
S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M. S. tubes for top & bottom rails. M. S. frame shall be covered with heat moulded plain colour PVC `C` channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M. S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and as directed by the Engineer-in-Charge.
M & L broken bricks loose filling with aggregates of gauge 80 to 150 mm in soakage pits, soakage wells complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing continuous (piano) hinges, mild steel, bright finish or electro galvanised, width of flaps when open in 30mm complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing brass CP fancy type handle 100 mm long complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing for magnet catcher suitable for cabinet etc fixed to wood complete all as specified and as directed by the Engineer-in-Charge.
M &L 10mm thick vitrified coloured paver tiles (Endura Tiles) of size 300 x 300mm in floors etc, set and jointed in neat cment slurry and pointed in white or coloured cement to match over and including 20mm thick screed bed in C.M 1 :4 ,complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in replacement, mild steel almirah shutters with frame, exceeding 1.5 Sqm, made of 1.00 mm thick, mild steel sheet, in two leaves as built in furniture in cupboards including locking arrangement with mortic lock of mild steel , vertical type, 65mm size, 2 lever, ISI marked with duplicate keys and handle, etc. (all as per Godrej pattern ) including two coats of synthetic enamel paint with spary painting over a coat of red oxide primer complete fixed in brick or concrete wall with six numbers of 10mm dia and 100mm long mild steel bolt with washer and nut in cement mortar (1:4) or PCC 1:2:4, type B-0 complete all as specified and as directed by the Engineer-in-Charge.
Dismantling water tanks of capacity exc. 250 ltr and not exc. 500 ltrs and removing from site complete all as specified and as directed by the Engineer-in-Charge
Schedule 'A' part-II ie E/M items
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, regulators, switch, socket outlet, bulk head fittings, tube light fittings, calling bell etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall surfaces and on surface on ceiling surfaces and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. and making smooth the disturbed surfaces as per existing for one light/fan/exhaust fan point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Description same all as per item No. 3.02 but for One 3 pin, 5 Amps, socket outlet controlled by one switch on independent board, complete all as specified and as directed by Engineer-in-Charge.
Description same all as per item No. 3.02 but for One 3 pin 5 Amps socket outlet controlled by one switch on same board, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Point wiring with 2.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall surfaces and on surface on ceiling surfaces and incuding provision of 2.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets, etc. and making smooth the disturbed surfaces as per existing for 3 pin, 15 Amp socket outlet point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Supply and fix modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fix modular switch 1 module, single pole, one way 16 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix modular socket outlet 2/3 pin, 6amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix modular socket outlet 2/3 pin, 16amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
S&F of electronic Fan regulator modular 120 watt 2 module 230 volts , 50 Hz, AC supply suitable for ceiling fan any type/make/sweep complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings,with one PVC block of size 75mm x75mm complete all as specified and as directed by Engineer-in-Charge.
Supply and fix LED Bulb, pin type 9 watt, energy efficient complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCB single pole, 240 volt, 6 to 32 amps, 10 KA 'C' curve complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCB double pole, 240 volt, 6 to 40 amps, 10 KA 'C' curve complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair MCB single pole, 240 volt, 6 to 32 amps, 10 KA 'C' curve complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in reapir sheet metal MCB DBs 8 way, single pole and neutral, double door, IP 43, as per IS 8623 with 200 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing reversible doors, PAN assembly for essy installation fixed on wall duly grouted in solid block wall or on wooden board and including copper lugs/thimbles duly crimped for connection, necessary PCC work and making smooth the disturbed surface complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix in reapir sheet metal MCB DBs 4 way, single pole and neutral, double door, IP 43, as per IS 8623 with 100 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing reversible doors, PAN assembly for essy installation fixed on wall duly grouted in solid block wall or on wooden board and including copper lugs/thimbles duly crimped for connection, necessary PCC work and making smooth the disturbed surface complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing 10 watt LED plastic batten with white acrylic cover, integrated LED channel and all accessories, prewired upto terminal block including connecting with 3 core copper conductor flexible cable from terminal box to the ceiling rose or connector of the light point complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair RCBO 40 Amps, 2 Pole, 4 module 30 mA (HI immunity) sensitivity 230 volts 50 Hz, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix in reapir over and low voltage release 230 volts, single phase in one module, suitable for (1 Ph+n) AC, adjustable for 170volts to 230 volts complete all as specified and as directed by the Engineer-in-Charge.
S&F sheet metal enclosure , MCCB,DB, Vertical IP 43 & 54 type, 6 way , TPN, double door , powder coated complete alongwith 125 Amp rated Bus bar ,suitable and including for MCCB, TPN ,100 Amps as incomer and MCB's as out going and making all type of connections with suitable size of gland for incommer cable complete , concealed on wall surface & making good distrubed surfaces as per existing adgoining surface . Note: For electric connection of MCCB, TPN suitable rating thimble / lugs should be used on cable ends. (2) Price of MCCB , TPN, 125 Amps. is included in the quoted rate.
S & laying as in repair sub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall and surface on ceiling in PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
Supply and fixing 20-22 Watt LED batten fittings complete including driver, aluminium body, pre wired rated voltage 240 Volt connecting with 2 core 1 sqmm copper conductor cable complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing LED tube light fitting 1x18/20 Watt, box type made from extruded aluminum high lumen out put 6500 K, AC 220-240 Volts, 50 Hz including tube rod (lamp type LED tube light fitting 1x18/20 Watt) and connecting up with three core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of light complete all as specified and as directed by Engineer-in-Charge.
S&F LED Bldg Security Light Fittings of capacity 40 -45 watt made up of die cast aluminium housing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including service bracket of GI pipe 32 mm bore medium grade of length 1.60 mtr with MS clamps, bolts, nuts, and washers and suitable reducer for connecting fitting to GI pipe as required at site including two coats of synthetic enamel paint over a coat of red oxide primer on mild steel work and making electrical connection, including disconnecting and taking down existing old Unserviceable fitting complete all as specified and as directed by the Engr-in-charge.
Supply and fix exhaust fan 300 mm sweep, anti corrsive metal body, sturdy metal bird guard copper wounded, double ball bearing, 1320 RPM,50HZ, 240 volts complete with dynamically balanced blade for vibration free rotation, split pin, clamp and fixing at site on and including MS fabricated base frame using flexible wire after making hole in wall as required at site and making good the disturbed surfaces and including making the electrical connection by using three core wire with colour code complete all as specified and as directed by Engineer-in-Charge.
Supply and laying laying XLPE insulated, armoured heavy duty LT UG electric cable 25 sqmm 3.5 core with multi stranded aluminium conductor, 1100 volts grade, complete all as specified and as directed by the Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for laying of cables. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed by Engineer-in-Charge.
Returning, Filling in excavated soils including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
M & L for dry sand as cushioning to cable 8 cm before laying cable in trenches and 15 cm after laying the cable and compacting, complete all as specified and as directed by the Engineer-in-Charge. Note:- for measurement, punned thickness shall be measured and paid.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 flat, size 250 mm x 150mm x 40mm complete all as specified and as directed by Engineer-in-Charge.
S&F light grade GI Tubing of size 40 mm dia for cable protection and fixed with clamp to pole and wall with nut bolts, including disconnecting and taking down existing pipe and removing complete all as specified and as directed by the Engineer-in-Charge.
Material & labour earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised iron wire earth lead of 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron, earth wire protected by GI pipe 15mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/c with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge and earth testing on completion . Note:- GI wire 4 mm dia upto 7.5 mtr lenght to be considered as one unit and the same deemed to include in the quoted rate.
Taking down ceiling fan, sealing cable end, dismantling blades and applying one coat of painting on ceiling fans with synthetic enamel paint by spraying incl filling cavaties with filler after cleaning all dust etc.and reassembling the same complete all as specified and as directed by the Engineer-in-Charge.
Fixing only the ceiling fan and connecting up including provision of flexible cable cable 23/.0076 from ceiling rose or connector to fan complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing indoor decorative recessed mounting 18 watt LED downlighter,6500 K, round shape with pressure dia cast aluminium housing for effective thermal management and high transmission factor PMMA diffuser for better performance and connecting up with three core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of light complete all as specified and as directed by Engineer-in-Charge.
bhagwandasswazirchand
V K Constructive Builders
MAYANK ENTERPRISES
Swami Enterprises
Karishan Kumar goel
M/s B.S.Jain
Ashwani Kumar
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .